| 1 | L1₹20.7 LAccepted-AOC PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹21.2 L+₹21,773 (1.04%)Rejected-Finance SR NO 331 2B PLOT NO 43 R H NO 02 BALDEWA RAO BUNGLOW NEWA NMC WATER TANK PATHARDI SHIVAR NASHIK 422 009 INDEX NO E 84CWE AF LOHEGAON PUNE | NASHIK | MAHARASHTRA | 422009 | L2 | Rejected-Finance Being Not L1 | |
| 3 | L3₹22.1 L+₹1.1 L (5.07%)Rejected-Finance | L3 | Rejected-Finance Being Not L1 | |
| 4 | L4₹22.4 L+₹1.4 L (6.81%)Rejected-Finance | L4 | Rejected-Finance Being Not L1 |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
4 Dec 2023, 6:00 pmClosed
GE AF OJHAR
GE AF OJHAR
REPAIR / MAINTENANCE OF VARIOUS DG SET AMF PANELS AND OTHER MISC WORKS AT DIFFERENT LOCATIONS, FIRE ALARM SYSTEMM CONTROL PANELS MAINT OF ETP ETC AT TECH AREA AT 11 BRD AF STN OJHAR
2023_MES_627260_1
8131/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
OJHAR
As per tender documents
8 documents required · 8 mandatory
₹500
GE AF OJHAR
₹56,000
Yes
23 Jan 2024
7 Nov 2023
6 Dec 2023
8 Nov 2023
4 Dec 2023
20 Nov 2023
Amount
M&L for Periodical maintenance of Effluent Treatment Plant (ETP) 6 KLD Effluent streams handling with - Cyanide, Chrome & Acid/Alkali, once in three month by checking & Testing all connected part complete all as directed by Engr-in-charge comprising with the following:- Checking the serviceability of following tanks and repair any leakage found and cleaning of tanks Cleaning of Acid Alkali, tank 2000 ltrs Cleaning of chrome tank 2000 ltrs Cleaning of chrome tank 2000 ltrs Cleaning of Neutalite tank 6000 ltrs Cleaning of Tube settelar tank 2000 ltrs Cleaning of Sludge tank 2000 ltrs Cleaning of Sand filter by removing sand and charcoal Cleaning of Carbon filter and removing filter Cleaning of filter Press Checked serviceability of Filter Press, Charcaol Filter (ACF), Bag filter System ,Pressure Sand Filter (PSF), Resin Filter (RF) and and cleaning the same as per OEM Instruction complete all as directed by Engr-in-charge General checking of all water and pump and servicing of motor including greasing of all parts
Supply only Caustic soda
Supply only Ferrous sulphate
Supply only Lime powder
Supply only Allum powder
Supply only Bleching powder
Supply only Hydocloric acid (HCL)
Supply only sand as per sample
Supply only Charcoal as per sample
Supply / Fixing Digital PH meter size 96X96 mX115 mm, range 0.00 to 14.00 pH, 220 Volt, AC, cailibrated on 7 PH Make as per sample.
Supply / Fixing Chemical dosing pump PT 200 max flow rate 6-25 LPH, 125 PSI/8.6 bar, 50 Hz, 45 watt Make as per sample.
Taking down existing unsv electric motor 3 phase, 415 volts, 50 HZ , capacity 1.5 to 3 KW motor of any make after disconnecting all electrical connection and shift to workshop for repair. Dismantling the motor , removing old burnt winding, cleaning the slots, checking and setting the stampings, providing a coat of insulating warnish, rewinding with super enamelled copper conductor winding wire of suitable gauge, packing the slots with insulating sleeves. drying in controlled temperature, re-assembling the motor with new set of bearings and connecting with its original place.
Taking down existing unsv Pump 3 phase, 415 volts, 50 HZ , capacity 1.0 to 3 HP pump of any make, shift to civil workshop for repair including all electrical connection and refixing the same on its original position incl testing.
Supply and fixing water Pump Head as per existing size
Supply and fixing PVC Pipe 40 mm dia for water supply connection of various pump motor to tank complete all as specified and directed by Engineer- in-charge.
All as per item no-15 but PVC Elbow 40 mm dia
All as per item no-15 but PVC Tee 40 mm dia
All as per item no-15 but PVC Socket 40 mm dia
AAll as per item no-15 but PVC Union 40 mm dia
All as per item no-15 butPVC NRV 40 mm dia
All as per item no-15 but PVC Pipe 25 mm dia
All as per item no-15 but PVC Elbow 25 mm dia
All as per item no-15 but PVC Tee 25 mm dia
All as per item no-15 but PVC Socket 25 mm dia
All as per item no- 15 but PVC Union 25 mm dia
All as per item no-15 but PVC NRV 25 mm dia
All as per item no-15 but PVC Stop cock butter fly 15 mm dia
All as per item no-15 but PVC Stop cock butter fly 25 mm dia
All as per item no-15 but PVC Stop cock butter fly 40 mm dia
S&F PVC flexible wire 2.5 sqmm 4 core
S&F PVC Flexible pipe 20 mm dia
S&F PVC Conduit pipr 20 mm dia
S&F Multi function meter
S&F Indicating lamp
S&F MCB SP 2Amp
S&F MCB TP 6 Amp
S&F Contactor (MNX 09 , 3 Phase 1No+1NC as per sample
S&F Relay as per existing size
M&L for monthly inspection /periodical maintenance/ break down maintenance incl six monthly servicing of Fire alarm system any type and make of different location of 11 BRD tech area ( Fire alarms, smoke detectors, fire panel , sesor etc ) once in month by checking & Testing to ensure proper function compete all as specified and as directed by Engr-in-charge , comprising of the following. Testing of smoke detectors and fire alarms to be functional Cleaning of fire alarm and other parts to prevent dirt and dust buid-up Ckecking of sesors and wiring to be all functional of Signal Section Make Bosch-01
All as per Item No-39 above but location RSDM Building Make - Bosch-01
All as per Item No-39 above but location RSDL (New) Building Make -Honeywell -03
All as per Item No-39 above but location RSDL (Old) Building Make - Bosch-01
All as per Item No-39 above but location ASD-30 Hanger Make - Hochiki-01
All as per Item No-39 above but location Launcher Bay Building Make - Siemens-01
All as per Item No-39 above but location PZ bay Make - Honey well-01
All as per Item No-39 above but location 762 SU Make - Bosch &Honey well-02
All as per Item No-39 above but location IT Make - Bosch-01
Supply ,install,testing & commissioning Addressable photoelectric smoke detector with base Model No HFP-11+ DB-11 of Make Siemens, complete all as specified & as directed by Engineer-In Charge
Supply ,install,testing & commissioning addressable manual call point Model No HMS-S of Make Siemens, complete all as specified & as directed by Engineer-In Charge
Supply ,install,testing & commissioning control relay for module for hooter Model No HTRI-R of Make Siemens, complete all as specified & as directed by Engineer-In Charge.
Supply ,install,testing & commissioning hooter cum strobe Model No MTH-MC-R of Make Siemens, complete all as specified & as directed by Engineer-In Charge
Supply ,install,testing & commissioning isolater module Model No HLIM-M of Make Siemens, complete all as specified & as directed by Engineer-In Charge
Supply and lay 2 core 1.5 sq mm armoured FRLS copper cable for interconnecting devices and fixing with the helpof suitable clamp, saddle, hanging insulator with GI wire 4 mm dia etc as reqd at site. Complete all as specified & as directed by Engineer-In Charge
M&L for GI tubing light grade with all fitting laid in trenches or fixed to wall or ceiling with clamps or fixed to floor complete all as specied and directed of size 20 mm bore, complete all as specified & as directed by Engneer-in Charge.
M & L for Preventive Checks/Breakdown Maintenance/serviceing of DG set by deputing Skilled Service Mechanic to attend the DG set as per the requirement for carrying out scheduled Preventive checks/Breakdown maintenance for smooth functioning of DG set of any Make all as directed by Engineer-in-Charge of following capacities:- (Major Spares Replacement will be Paid Seperately under respective items below) at DG Set 250 KVA Location -ROH
All as per item no- 55 above but DG Set 200 KVA Location -RSDL(N)
All as per item no- 55 above but DG Set 125 KVA Location -MAP Sub STn
All as per item no- 55 above but DG Set 125 KVA Location -HQ
All as per item no- 55 above but DG Set 82.5 KVA Location -IT
All as per item no- 56 above but DG Set 75 KVA Location -OTS Hall
All as per item no- 55 above but DG Set 75 KVA Location -Tapovan
All as per item no- 55 above but DG Set 62.5 KVA Location -LSW server
All as per item no- 55 above but DG Set 40 KVA Location -ASD-29
All as per item no- 55 above but DG Set 40 KVA Location -Pump House Raksh Nagar
All as per item no- 55 above but DG Set 40 KVA Location -MT
All as per item no- 55 above but DG Set 40 KVA Location -CIMD
All as per item no- 55 above but DG Set 40 KVA Location -KV Sub stn
All as per item no- 55 above but DG Set 40 KVA Location -Airmen Mess
All as per item no- 55 above but DG Set 40 KVA Location -STP-1
All as per item no- 55 above but DG Set 30 KVA Location -CIMD 3 D
All as per item no- 55 above but DG Set 30KVA Location -SMC
Supply and Fix in Replacement of Spares for Repairing of DG Set 250/200 KVA:- Make:- Cummins/KOLE, Lub Oil filter suitable for 200 KVA , Make:- Cummins
Supply and Fix in Replacement Diesel Fuel filter suitable for 200 KVA , Make:- Cummins
Supply and Fix in Replacement Air filter (inner and outer) suitable for 200/250 KVA, Make:- Cummins
Supply and Fix in Replacement Hose Pipe Set suitable for 200/250 KVA , Make:- Cummins
Supply and Fix in Replacement Hose Clip Set for 200/250 KVA, Make:- Cummins
Supply and Fix in Replacement V belt Set suitable for 200/250 KVA , Make:- Cummins
Supply and Fix in Replacement Solenoid fuel pump. suitable for 200/250 KVA , Make:- Cummins
Supply and Fix in Replacement Starter Servicing
Supply and Fix in Replacement Supply and Fix in Replacement of Spares for Repairing of DG Set 125/82.5 KVA:- Make:- Cummins Lub Oil filter suitable for 125 KVA/82.5 , Make:- Cummins
Supply and Fix in Replacement Diesel Fuel filter suitable for 125 KVA/82.5 , Make:- Cummins
Supply and Fix in Replacement Air filter (inner and outer) suitable for 125 KVA/82.5 , Make:- Cummins
Supply and Fix in Replacement Hose Pipe Set suitable for 125 KVA82.5 KVA , Make:- Cummins
Supply and Fix in Replacement Hose Clip Set for 125 KVA/82.5 KVA , Make:- Cummins
Supply and Fix in Replacement Supply and Fix in Replacement of Spares for Repairing of DG Set 75 KVA:- Make:- KirloskarDiesel Fuel filter suitable for 75 KVA
Supply and Fix in Replacement Lub Oil filter suitable for 75 KVA
Supply and Fix in Replacement Air filter (inner and outer) suitable for 75 KVA.
Supply and Fix in Replacement Hose Pipe Set suitable for 75 KVA.
Supply and Fix in Replacement V belt Set for 75 KVA
Supply and Fix in Replacement Solenoid fuel pump. for 75 KVA.
Supply and Fix in Replacement Starter Solonoid for 75 KVA.
Supply and Fix Starter Servicing for 75 KVA.
Supply and Fix in Replacement Automatic Voltage Regulator (AVR) as per Existing Complete
Supply and Fix in Replacement VMR Panel Mounting for 75 KVA.
Supply and Fix in Replacement Battery Charger 12V,10Amp SMPS Base
Supply and Fix in Replacement Fly wheel Gear Ring for 75 KVA.
Supply and Fix in Replacement Head Gasket suitable for 75 KVA.
Supply and Fix in Replacement following Spares for Repairing of DG Set of Capacity 62.5 KVA:- Make:- Cummins Diesel Fuel filter suitable for 62.5 KVA , Make - Cummins
Supply and Fix in Replacement Lub Oil filter suitable for 62.5 KVA , Make - Cummins
Supply and Fix in Replacement Air filter (inner and outer) suitable for 62.5 KVA , Make - Cummins
Supply and Fix in Replacement Hose Pipe Set suitable for 62.5 KVA , Make - Cummins
Supply and Fix in Replacement V belt Set suitable for 62.5 KVA , Make - Cummins
Supply and Fix in Replacement Solenoid fuel pump. suitable for 62.5 KVA , Make - Cummins
Supply and Fix in Replacement Starter Solonoid suitable for 62.5 KVA , Make - Cummins
Supply and Fix Starter Servicing
Supply and Fix in Replacement Automatic Voltage Regulator (AVR) as per Existing Complete
Supply and Fix in Replacement AMF Controller suitable for 62.5 KVA.
Supply and Fix in Replacement Battery Charger 12V,10 Amp SMPS Base
Supply and Fix in Replacement Fly wheel Gear Ring suitable for 62.5 KVA.
Supply and Fix in Replacement Head Gasket suitable for 62.5 KVA
Supply and Fix in Replacement Tappet Cover Gasket suitable for 62.5 KVA.
Supply and Fix in Replacement of Spares for Repairing of DG Set 40 KVA:- Make:- Kirloskar Diesel Fuel filter suitable for 40 KVA.
Supply and Fix in Replacement Lub Oil filter suitable for 40 KVA.
Supply and Fix in Replacement Air filter (inner and outer) suitable for 40 KVA
Supply and Fix in Replacement Hose Pipe Set suitable for 40 KVA.
Supply and Fix in Replacement V belt Set for 40 KVA.
Supply and Fix in Replacement Solenoid fuel pump. for 40 KVA.
Supply and Fix Starter Solonoid for 40 KV
Supply and Fix in Replacement Starter Servicing for 40 KVA.
Supply and Fix in Replacement Automatic Voltage Regulator (AVR) as per Existing Complete
Supply and Fix in Replacement Engine Safety Unit for 40 KVA.
Supply and Fix in Replacement Wiring Harness for 40 KVA.
Supply and Fix in Replacement Fly wheel Gear Ring
Supply and Fix in Replacement Head Gasket suitable for 40 KVA.
Supply and Fix in Replacement Supply and Fix in Replacement of Spares for Repairing of DG Set 30 KVA:- Lub Oil filter suitable for 30 KVA , Make:- Cummins
Supply and Fix in Replacement Diesel Fuel filter suitable for 30 KVA , Make:- Cummins
Supply and Fix in Replacement Air filter (inner and outer) suitable for 30 KVA , Make:- Cummins
Taking down radiator from Gen set of capacity 62.5/75/82.5 KVA after disconnecting the water connecting pipe, descaling, cleaning properly with high pressure wash to remove greasy substances from water tubes, tank and outer fins and re-fixing the same after servicing complete and replacement of coolant solution and hose radiator with clips complete all as directed by Engineer-in-Charge.
Taking down radiator from Gen set of capacity 40 KVA after disconnecting the water connecting pipe, descaling, cleaning properly with high pressure wash to remove greasy substances from water tubes, tank and outer fins and re-fixing the same after servicing complete and replacement of coolant solution and hose radiator with clips complete all as directed by Engineer-in-Charge.
Supply and fixing coolant concentrate Make : Valvoline
Dismantling and taking out Dynamo/alternator assembly of 12 Volts/24 Volts from the DG sets replacing the spare parts such as carbon brushes, springs, spring holders, brushes, bearings or any other part required for full functioning of machine and fixing and testing complete as specified and directed by Engineer-in-Charge
Dismantling and taking out dynamo/alternators from DG set for rewinding and taking out the old coil, cleaning thoroughly and wound with new super enameled copper cord of existing size and gauge, varnishing, drying, heating as per manufacturer norms and fixed with dynamo/alternator properly testing and commissioning suitabl;e for40 to 62.50 KVA all as specified and directed by Engineer-in-Charge
S&F in replacement of radiator hoses of any size and any capacity of DG set and fixed properly with new jublee clips, clamps, nuts and testing complete as directed by Eng-in-charge
Dismantling and taking out the FIP (PT Pump Assy) for repairing by replacing the worn out gasket, filter, suction valve, discharge valve and fixing the same after calibration and testing complete as directed by Engr-in-charge of capacity 200 KVA / 250 KVA/ DG set. Note : Repairing & Calibration shall be carried out by authorised dealers only.
As per item No 134 above but for DG set of capacity 82.5KVA/75KVA/62.5KVA
As per item No 134 above but for DG set of capacity 40KVA
Supply and fixing in repair AVR unit for 250/200/125 DG Set & testing etc complete as specified and directed by Engr-in-charge Make : Kirloskar/Cummins
Supply and fixing in repair AVR unit for 82.5KVA/75KVA/62.5KVA DG Set and testing complete as directed by Engr-in-charge . Make : Kirloskar/Cummins
Supply and fixing in repair AVR unit for 40KVA DG Set and testing etc complete as directed by Engr-in-charge . Make : Kirloskar/Cummins
Dismantling and taking out the water body pump assembly complete from the DG set upto capacity 75 KVA at site and Supply and fixing of new water body pump complete.
Supply & fix battery terminals made of brass superior quality incl taking down old one etc complete as directed.
Dismantling and taking out the dfective self starter assembly of any capacity (12V/24V) form the DG set and re-fixing the same after repair works including replacing the spare parts such as carbon brushes, springs, spring holder bushes, bearings, or any other spare part not mentioned herein but essentially required for proper functioning of the starter assembly complete all as specified and directed.
Dismantling and taking out self starter from DG set and taking out unserviceable old coil , cleaning thoroughly slot and rewinding the starter with super enameled copper conductor of existing size and gauge incl varnishing drying, heating and re-fixing the same after repair incl testing all as specified and directed.
Supply & Fixing flexible pressure hose for lubricant oil and fuel for any size/capacity/model/make of DG set incl taking down old one etc complete all as specified.
Dismantling the radiator of 82.5 to 40 KVA DG set its position and soldering of copper pipes, where leakage incl rectifying leaks & cleaning radiator and PVC hose and fitting the same place and testing complete as specified
Material and labour for draining out old engine/lubrication oil from chamber of the DG sets, cleaning of chamber thoroughly and filling new engine/lubrication oil of grade 20W40 complete all as specified and directed.
S & F battery leads 95 Sqmm copper cable unth as reqd at site etc complete as specified and directed by Engr-in-charge
Material and labour for dismantling and taking out the alternator above 40 KVA but upto 82.5 KVA capacity from the DG sets from coupling and opening the stator & rotor including cleaning of dust from windings for proper ventilation, renewal of carbon brushes with brush holder and re-assembling the rotor & stator complete including applying suitable greasing & oiling of bearing & moving parts and refixing the same on its position and testing complete all as specified and directed.
Supplying, fixing lead acid battery 12 volts, 180 AH suitable for DG set including initial charging (Model No. FXPO-MHD1800 Exide New express or equivalent of other specified make) including connection & testing and taking down old one etc complete all as specified and directed.
Supplying, fixing lead acid battery, 12 volts, 80/110 AH with lead acid suitable for DG set including initial charging (Make- EXIDE / AMRON ) including connction and testing incl taking down old one complete as specified and directed .
Supply and fixing distilled water for batteries.
Supplying & fixing Exhaust Gasket as per existing make/model/type of capacity of DG set 40 KVA DG Set incl taking down old one etc complete as specified and directed Note : 128 to 153 - (i) DG set should be repair within 12 hours after receiving the massage from department. If the contractor fail the repair of DG set within perioud, the penality should be paid 250/per hours to department. (ii) Any minor material/spare reqd for proper functioning wheather not cover in CA Contractor will provide the same for functioning of D G set.
Material and labour for servicing/repair of AMF Panel of DG Set up to 250 KVA capacity for smooth functioning of the same with renewal / repair of AMF panel, wiring control timer, engine starting relay, contact point repal, AMF relay, HRC fuse of existing rating etc complate for DG sets installed at various pockets under AGE E/M Ojhar all as specified and as directed. Note:- The rate quoted by the contractor shall be deemed to included the cost of spares/relays or any other part not mentioned herein but essential required to make the AMF panel completely functional and no extra payment shall be made for the same.
Supply and fixing Batter charger 12 V,DC, 2 Amp complete as specified and directed .
Supply and fixing Foam sound obsorver as per existing make, suitable to fit in DG set door inner side up to 82.5 KVA DG Set incl taking down old one etc complete as specified and directed .
Supply and fixing push button as per existing make, model and capacity etc suitable for 40/62.5 KVA DG Set incl taking down old one etc complete as specified and directed .
S&F off load changeover switch 63 Amps TPN with sheet metal enclosure ,side handle operated, 50 Hz, fixed to walls/ panels with suitable size clamps, nuts, bolts and washers complete all as specified and directed including making connections and testing of following capacities:- Make - L&T/Schneider/C&S/indoasian/HPL
All as per Item No 158 above but 100 Amps
All as per Item No 158 above but 200 Amps
Supply & Fixing in repairs "ON LOAD" type Change over switch 200 Amps TPN front handle operated, on existing LT/AMF Panels, suitable for three phase, 415V, 50 Hz AC supply of following ratings :- Make - L&T/Schneider/C&S/indoasian/HPL
All as per Item No 161 above but 100 Amps
All as per Item No 161 above but 63 Amps
S&F MCCB TP of capacity 100/63 Amps, 50 Hz, 415V with rupturing capacity of 16 KA with fixed thermal magnetic settings including spreader terminals complete incl taking down old one etc complete all as specified and directed.
Current Transformer with CT ratio 100/5 as per sample.
Contactor FP, 3 Phase 63 A FP , AC as per sample
M&L for maintenance of DG set Canopy door by taking down door from DG set denting the damaged portion of MS door and weilding the same if reqd for any desire shape and cleaning the old painted srface of Door and painting with synthetic enamel paint as existing colour to achive good finish.
Dismantling and taking out the dfective door lock assembly of any capacity of the DG set and re-fixing the same after repair works including replacing the defective spare parts as reqd at site. complete all as specified and directed.
Shree Sai Samarth Enterprises
K R Electricals
DIAMOND ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .