Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.3 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹26.5 L+₹3.9 L (17.1%)Rejected-Finance A 4 TARINI APARTMENT PHASE I KILBURN COLONY HINOO DISTT RANCHI JHARKHAND 834002 | RANCHI | RANCHI | JHARKHAND | 834002 | L2 | Rejected-Finance HIGHER | |
| 3 | L3₹29.3 L+₹6.6 L (29.4%)Rejected-Finance | L3 | Rejected-Finance HIGHER | |
| 4 | L4₹29.6 L+₹7.0 L (30.9%)Rejected-Finance | L4 | Rejected-Finance HIGHER | |
| 5 | L5₹31.9 L+₹9.3 L (41.0%)Rejected-Finance | L5 | Rejected-Finance HIGHER |
Tender Value
₹30.9 L
EMD Value
₹61,880
Closing Date
13 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Amritsar
GARRISON ENGINEER AMRITSAR CANTT PIN 143001
ADDN/ALTN TO BLDG NO P-67/1 OF 15 ARTY BDE OFFRS MESS UNDER GARRISON ENGINEER AMRITSAR CANTT
2024_MES_654374_1
GE/ASR-46/2024-25
Open Tender
Civil Works
Works
180 days
GE Amritsar
CLASS D CATEGORY a i
8 documents required · 8 mandatory
₹500
GE Amritsar
₹61,880
28 Oct 2024
16 May 2024
14 Jun 2024
16 May 2024
13 Jun 2024
30 May 2024
Amount
Material and Labour for Cutting openings, through brick walls built in cement mortar for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. to store and rubbish not exc. 50m ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for Forming jambs, etc. to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, ; Complete all as specified and directed by Engineer-in-charge.
Taking down Chowkats or frames from the opening of size exceeding 1.5 sqm and not exc 4 sqm each with shutters ( without taking off shutters from the frames) ; Complete all as specified and directed by Engineer-in-charge.
Cement concrete type D2, 1:4:8 (40 mm graded aggregate) in foundations, filling and mass concrete ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour RCC(Design Mix) M-25 (20mm graded aggregate) in column, pillars, piers, post and struts. ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for RCC (Design Mix) M-25 (20 mm graded aggregate) as in Beams, canatilivers, bressummers, lintels over 1.5m span etc ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of rough finished surfaces of concrete in foundation and plinth beams; and similar work; vertical or to batter ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Formwork to sides of pillars, posts, struts, piers, columns and stanchions of rough finished surfaces of concrete. ; Complete all as specified and directed by Engineer-in-charge.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide. ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour TMT Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips. ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour TMT Mild steel bars 6 to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
Ditto as item No 12 but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders.
Material and Labour brick work with sub class 'B' bricks straight curved on plan exc 6 mean radius built in CM 1:6 ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for Rendering 15 mm thick on fair/unfair faces of brick work or concrete surfaces in CM 1:6 and to be finished even and smooth ( without using extra lime or cement) ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour Providing and applying plaster of paris putty of 1 mm thickness over plastered surface toprepare the surface even and smooth. ; Complete all as specified and directed by Engineer-in-charge.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 5489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of interior primer applied @ 0.90 litre/ 10 sqm over new surfaces. ; Complete all as specified and directed by Engineer-in-charge.
Material & Labour for complete removal of existing treatment from old existing wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 5489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of interior primer applied @ 0.90 litre/ 10 sqm over new surfaces. ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for Rendering 15 mm thick on fair/unfair faces of brick work or concrete surfaces in CM 1:4 and to be finished even and smooth ( without using extra lime or cement) ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) including preparation of new surfaces ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour Finishing walls with Acrylic Smooth exterior paint of required shade : old work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) including preparation of old surfaces ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for Rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM 1:3 as on ceiling and to be finished even and smooth ( without using extra lime or cement)
Material and labour preparation of newly plastered surface of wall and applying three coats of white wash on ceiling surface ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour Seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish (Frame work for ceiling shall be measured and paid separately. ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. ; Complete all as specified and directed by Engineer-in-charge.
Material and labour preparation of newly surface of Ceiling and Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work ; Complete all as specified and directed by Engineer-in-charge.
Dismantling brick tiles or terracing tiles single layer in roof ; Complete all as specified and directed by Engineer-in-charge.
Demolition mud phuska in roofs any thickness including plastering and leeping ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) in bed blocks for hold fast & similar work etc ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour Cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in roof padding (avg 40mm thick), roof kerbs or mud stops, rounded or chamfered on edge ; Complete all as specified and directed by Engineer-in-charge.
Material and labour for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) laid on primed surface by forced application over a tack coat of in dustrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for Cement concrete tiles 20cmx20cmx20mm thick,machine pressed ; set, jointed and pointed in neat cement slurry in floors with grey cement and no pigment, and cut and polished over and including 15mm thick screed bed in CM 1:4 ; Complete all as specified and directed by Engineer-in-charge.
Supply and fixing factory made uPVC white colour fixed glazed window/ventilator of any size (as required) fixed type or openable type made of frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Glass shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Net opening will be measured for payment purpose.
Supply and Fixing 08mm thick toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour Granite (of any type) work (table rubbed and polished) 20mm thick in steps , jambs, pillars, window cills, cooking plateforms and like in cemnet mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15mm thick rendering in CM 1:4. ; Complete all as specified and directed by Engineer-in-charge.
Material & Labour for providing and fixing toughned glass 12mm thick as in hinged door, partitions automatic doors and similar work including cutting to shape, drilling holes and all necessary items as required ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box,main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Floor door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring fixed to door shutter of size 150mm. ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Brass mortice lock, 4 levers, verticle type, size 100 mm, ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Brass mortice lock, 2 levers, verticle type, size 100 mm, ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing 450mm long Brass handles, cast type ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for frosted to toughned glass of any thickness ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for Embossed any type of emblem of size 0.45x0.45M on frosted glass door ; Complete all as specified and directed by Engineer-in-charge.
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repairs 25mm dia stainless steel Curtain rods/ rails with Brass brackets, stops, rollers, finials, 1 pair of Brass decorative knobs for each curtain rod etc. ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing 18 mm thick PVC board as in shelves for kitchen cabinets etc ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing 5 mm thick PVC board as in back side of for kitchen cabinets etc ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing 18 mm thick PVC shutters one side prelaminated of any shade for cupboard cabinets etc ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing 40mm long self closing type hydraulic steel hinges ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing 75 to 80 mm long brass handle ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for broken bricks Hardcore of gauge n exc. 63 mm, deposited , spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface
Material and Labour 75mm thick Cement concrete type D2, 1:4:8 using 40mm graded agregate as in sub base of floor ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour Cement concrete 75 mm thick type C-2 (1:3:6) using 40 mm graded stone aggregate as in plinth protection etc finished even and smooth using extra cement ; Complete all as specified and directed by Engineer-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing), removing serviceable tiles to store and rubbish off the premises. ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for Vitrified ceramic dark shade tiles 10mm thick (Square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm in floors and skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of cement mortar(1:6) 15mm thick for laying floor finishes ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repairs of One piece ceramic floor/wall mounted EWC with features like twin flush system, noisless soft close seat cover, anty-bacterial surface white with PVC(SWR) 'P' / 'S' trap 110/110mm bore ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repairs PVC Jet spray suitable for EWC. ; Complete all as specified and directed by Engineer-in-charge.
Supply and fixing Chromium plated Health faucet in repairs with 1.5 metre long chain. ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repairs glass shelve assembly 60cm in oval shape consisting 5.5mm to 8mm thick glass including CP guard railing with double rail. ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Sheet glass corner shelf assembly consisting of three nos 5.5mm to 8mm thick sheet glass corner shelf with chromium plated bracket guard and railing. ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing PVC connection 15mm size with PTMT nuts of length 600mm. ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Brass chromium plated Wall mixer with bend pipe in repairs suitable for mixing Hot & Cold water and making leakagefree connection with wall tiles & GI pipes. ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing 15mm bore Concealed type stop cock cast copper alloy CP screwed down high pressure with crutch or butterfly handle complete. ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing 15mm bore type angle cock cast copper alloy CP screwed down high pressure with crutch or butterfly handle ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing of brass cromium brass plated fancy type bib taps 15 mm bore long nose screwed down screwed for iron pipe or for brass ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repairs Pillar taps 15mm bore, cast copper alloy , with capstan heads, chromium plated , screwed down high pressure , with or without l'ettered ' 'HOT' or 'COLD' with long screwed shanks and fly-nuts , screwed for iron pipe and fixed. ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repairs PVC waste pipe 32mm dia fixed to WHB/Urinals. ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repairs 100mm dia CP grating with or without hole type ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Vanity of size 820x450mm with vitreous China wash basin white,with suitable size including CP waste coupling 32mm bore,waste PVC pipe ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in rfepairs CP brass towel rail of 20mm dia and 600mm long ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repairs 125mm CP shower rose fancy type with CP arm ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Vitrous china white (Box type) toilet paper holder fixed to walls with chromium plated (CP) brass screws ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing 15mm bore tubes (medium grade) galvanised with all fittings and fixed to walls and ceiling or laid in floors complete including taking down ; Complete all as specified and directed by Engineer-in-charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft soil.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. ; Complete all as specified and directed by Engineer-in-charge.
Removing excavated material n.exc 50 m and depositing where directed ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for Excavating in post holes( or similar holes) in soft/loose soil each n exc 0.5 cu.m. getting out, returning,filling in and ramming earth of broken rubble mixed with earth around , in layers not exceeding 25 cm, watring, and removing surplus soil to a distance n.exc 50 m and making good surface ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing mild steel Gde Fe-410-W as in roof trusses, (framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee,angle,channel or flat sections) including distance pieces , cleats etc. ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Fiber glass reinfored translucent 2 mm thick Pain sheet fixed wwith coach screw and washer in roof , wall ete ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for PCC 1:3:6 type C-2 ( using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete of post holes. ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for preparing new steel surfaces and applying two coats of synthetic enamel pait over a coat of red oxide ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Solid Wall Pannling consisting 5mm to 10 mm thick plain cloure PVC sheet duly fited in to the wall including fillet as per ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing mild steel angle iron work as in Door/ Gate and struts including cutting tops to shape as directed drilling holes notching for wire. Conforming to Fe-290 Gde E-165. ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Preparation of New or Previously untreated surfaces of any description , over 10 cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of Red oxide primer. ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing for pre-painted galvalume aluiminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws as ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for two coats of smooth interior acrylic emulsion with Texture finish having VOC less tham 50 grams per ltr complying LEEDS criteria@ 1 ltr ( unndiluted)/ 10sqm mtr diluted with water in 2:1 ratio applied over priming coat with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute in both the coats of paint as per manufacturer instructions ; Complete all as specified and directed by Engineer-in-charge.
Dismantling water tanks Exc 250 Ltr & not exceeding 500Ltr and Supply and Fixing rotational moulded polythene, triple layers, water storage tank 500 Ltr capacity, closed top, cylindrical, hoisted and fixed in position including Supply and Fixing 20mm bore PTMT ball valve epoxy coated minium weight 210gms with aluminium rod ; Complete all as specified and directed by Engineer-in-charge.
Dismantling water tanks Exc 500 Ltr & not exceeding 1000 Ltr and Supply and Fixing rotational moulded polythene, triple layers, water storage tank1000 Ltr capacity, closed top, cylindrical, hoisted and fixed in position including Supply and Fixing 20mm bore PTMT ball valve epoxy coated minium weight 210gms with aluminium rod ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing 20mm bore tubes (medium grade) galvanised with all fittings and fixed to walls and ceiling or laid in floors complete including taking down ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for surface dressing n exc 15 cm deep soft/loose soil. ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for broken bricks Hardcore of gauge n exc. 63 mm, deposited , spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour 75mm thick Cement concrete type D2, 1:4:8 using 40mm graded agregate as in sub base of floor ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for Machine pressed coloured precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and pigments over and including 50mm thick sand cushioning ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour PCC (1:2:4) type B1 using 20mm graded stone aggregate as in kerbs or mud stops, rounded or chamfered on edges ; Complete all as specified and directed by Engineer-in-charge.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials and making good disturbed surfaces of walls, floors, etc. ; Complete all as specified and directed by Engineer-in-charge. NOTE: Cost of unserviceable materials will be charged from the contractor against Schedule of Credit.
Taking down carefully existing serviceable Ceiling fan/Wall mounted fan, ceiling cable end, etc., removing the fan for keeping in safe custody, hanging the ceiling fan with down rod after rewiring including clamps, hooks, holdfasteners etc and connecting up, including making electric connection from ceiling rose or connector to fan ; Complete all as specified and directed by Engineer-in-charge.
Taking down carefully existing serviceable exhaust fan, ceiling cable end, etc., removing the fan for keeping in safe custody, fixing the exhaust fan after rewiring and connecting up, including making electric connection from ceiling rose or connector to fan ; Complete all as specified and directed by Engineer-in-charge.
Taking down carefully old unserviceable Geysers of capacity 25 ltrs, ceiling cable end, etc., dismantling all accessories by unscrewing, removing the geyser & deposit to MES store yard, including making good to the disturbed surface of wall ; Complete all as specified and directed by Engineer-in-charge.
Taking down carefully Split type AC of any capacity by disconnecting from the either terminals, ceiling cable end, etc., including all fittings and fixtures by unscrewing, removing the AC & deposit to store yard, making good to disturbed surface of wall complete as directed by Engr-in-Charge
Material and Labour for point wiring for One light point/Bell/Fan point controlled by one switch. complete with 1.5 sqmm single core PVC insulated sheathed multi-stranded, copper conductor FRLS grade cable of 1100 volts grade conforming to IS:694 drawn through and including non metalic rigid PVC conduit, medium grade, ISI marked, not less than 20mm bore with conduit accessories concealed on wall and ceiling/roof etc, with provn for fixing modular metal flush boxes not less than 1.0 mm thick of suitable modules, concealed in walls with modular white plated cover as top cover fixed with screws for housing switches, socket outlets, fan regulators etc, including provn of 1.5 sqmm nominal cross sectional area, PVC insulated, FRLS, sheathed, 1100 volt grade,multistranded single core green colour copper conductor for earth continuity connected to earth dolly ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for point wiring for One 3 pin 5 Amps socket outlet on independent board by one switch. complete with 1.5 sqmm single core PVC insulated sheathed multi-stranded, copper conductor FRLS grade cable of 1100 volts grade conforming to IS:694 drawn through and including non metalic rigid PVC conduit, medium grade, ISI marked, not less than 20mm bore with conduit accessories concealed on wall and ceiling/roof etc, with provn for fixing modular metal flush boxes not less than 1.0 mm thick of suitable modules, concealed in walls with modular white plated cover as top cover fixed with screws for housing switches, socket outlets, fan regulators etc, including provn of 1.5 sqmm nominal cross sectional area, PVC insulated, FRLS, sheathed, 1100 volt grade,multistranded single core green colour copper conductor for earth continuity connected to earth dolly ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for point wiring for One 5 Amps outlet point on same board with other switches/sockets complete with 1.5 sqmm single core PVC insulated sheathed multi-stranded, copper conductor FRLS grade cable of 1100 volts grade conforming to IS:694 drawn through and including non metalic rigid PVC conduit, medium grade, ISI marked, not less than 20mm bore with conduit accessories concealed on wall and ceiling/roof etc, with provn for fixing modular metal flush boxes not less than 1.0 mm thick of suitable modules, concealed in walls with modular white plated cover as top cover fixed with screws for housing switches, socket outlets, fan regulators etc, including provn of 1.5 sqmm nominal cross sectional area, PVC insulated, FRLS, sheathed, 1100 volt grade,multistranded single core green colour copper conductor for earth continuity connected to earth dolly ; Complete all as specified and directed by Engineer-in-charge.
All as per ser item No. 102 here in above but point wiring with 2.5 Sqmm FRLS cable and 2.5 sqmm cable earth continuity wire for one 3 pin socket outlet,15 Amps on independent board. NOTE FOR ITEM NO. (i) The wiring shall be done in proper colour coding using red, yellow and blue for phase, black for nuetral and green for earth wire. (ii) Modular metal flush boxes concealed in wall with suitable cover plate for mounting switch, sockets, regulator etc. and cost of cutting chases & making good as existing to disturbed surface with cement mortar, if required any shall be deemed to included in the quoted rates. (iii) Modular fittingSupply and Fixingixtures such as switch, socket, regulator, etc., shall be measured and paid separately as under relevant item.
Supply and Fixing modular switch 1 way 6A, 240 volts, 1 module ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing modular socket, 6A, 240 volts, 2/3 pin combined 2 module, flush type ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing modular switch 1 way 16A, 240 volts, 1 module ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing modular socket, 6A/16A, 240 volts, 2/3 pin combined 2 module flush type ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing modular bell push, one way, 6 Amps, 240 Volts, 1 module complete all as directed by Engr-in-Charge
Supply and Fixing modular fan step regulator, 2 module, 240 Volts, 50 Hz, suitable for ceiling fan ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing ceiling rose surface PVC/Polycarbonate, isolated body with face Bakelite 65 x 50 mm three terminal, 240 volts, AC single phase ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing buzzer, Ding Dong, AC, 240 Volts, single pole, fixed over & including pressed steel sunk box of size 175 x 100 mm duly covered with 3mm thick bakelite sheet ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Lamp holder angular type, PVC/Polycarbonate type with back plate suitable for batten fittings including 10cm x 10cm presto plastic board for resting to holder including Supply and Fixing 01 x 10/12 watts LED lamp, 230 volts ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing sheet steel metal enclosure single pole & neutral with a 2 pin and earth plug and socket complete with one single pole MCB SP 20 Amp, 240 volts ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing LED lights fitting 1x 20W, 220V, AC, 5700K, decorative box type with driver, double sided connection, CRI> 80, PF>95%, THD<10%, Lumen>2100 lm including LED tube light connecting up with 3 core flexible copper conductor cable (1.0 mm² size/core) from ceiling rose ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Wall mounted, indoor, HELIOS Mirror Light LED with aluminium die cast, suitable for and including 10 watt 6000K, WH LED light, prewired with 3 core flexible copper cable (1.0 mm² size/core) from connector to light fittings and connecting up ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing COMET ROUND Slim surface mounted round shape 15 watt 220 volts AC, 6000K recessed type LED luminaire, die-cast aluminium body with specular finish aluminium reflector of fixture size 107x78mm and ceiling cut out of 92mm dia with IP-20 protection with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with 3 core flexible copper conductor cable of suitable size ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing PLUTO NEO LED luminaire 600mm x 600mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size ; Complete all as specified and directed by Engineer-in-charge.
Supply, install & testing exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, single phase, 1200 RPM, Copper winding of sweep 300mm complete fixed/grouted to wall with suitable bolts, nuts etc., and connecting up with & including 3 core flexible copper conductor cable (1.0 mm² size/core) from ceiling rose to exhaust fan and writing MES No. including cutting hole suitable for fixing exhaust fan ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing ceiling fan 1200mm sweep complete with blades, down rod as per site requirement, electronic regulator & accessories (i.e. PVC canopy, rubber bush, split pin, hanging clamp, holdfasteners etc.) 230 Volts, white colour, with min air delivery 210 CFM, BEE 5 star rated with brushless direct current motor (BLDC) technology and connecting up with & including 3 core flexible copper conductor cable (1.0 mm² size/core) from ceiling rose to ceiling fan and writing MES No. ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing LED lights fitting decorative type, fancy/aesthetic design (Make as per sample as directed) with & including provn of fixing LED bulb 1x 9W/10W, 220V, AC including connecting up with 3 core flexible copper conductor cable of suitable size from ceiling rose, including taking down existing unsv one of any type & size from site ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Wall mounted fan of 400mm sweep plastic body and blade including pull cords for speed regulation & wide oscillation control, with 1300 RPM, 60 air delivery, 50 Watt, colour ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing cable junction box made out of polycarbonate, fully UV ray protected, shock & weather proof, dust, rust & water proof, IP-66 with integrated membranes for cable entry of 10-16 sqmm 2 core cable through gland of suitable size, neutral disconnected terminal, busbar terminals, including MCB SP 6A for connecting 2 core 10 sqmm cable to control post-top LED light fitting, alongwith MS clamps of 25mm width, 3mm tick MS flat strip for fixing of junction box, including provn of 2.5 sqmm X 2C weather proof PVC insulated copper conductor cable passing through the hole of GI pipe from junction box to post-top light luminair ; Complete all as specified and directed by Engineer-in-charge.
Supply and Laying in trenches/drawn through pipes or in road crossings/paths/drains/ ductSupply and Fixingloors/along poles/equipments etc., of LT cable under ground, heavy duty, armoured, XLPE insulated with multi-stranded aluminium conductor cable conforming to IS-7098 Part-I (1998), 1100 Volts grade of 35 Sqmm 3½ core nominal cross sectional area including necessary double compression copper gland and connecting up using suitable size aluminium lugs testing, incl taking down old unsv one from site ; Complete all as specified and directed by Engineer-in-charge. NOTE: Excavation & earthwork will be measured and paid separately
All as per ser item No. 123 above but 10 sqmm 2 core ; Complete all as specified and directed by Engineer-in-charge.
Supply & laying double wall corrugated (DWC) high density poly ethylene (HDPE) of size 40mm dia including all necessary fittings, PN-4 rating, pressure 6 Kgf/cm², conforming to IS-16205 (Part-24) with high ring stiffness & cursh resistance capacity, etc., laid in trench for protection of submersible flat cable ; Complete all as specified and directed by Engineer-in-charge.
Excavating in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation for erection of poles, stays, laying cables, stays etc and getting out in soft/loose soil and in road cutting ; Complete all as specified and directed by Engineer-in-charge.
Returning, filling in excavated material/soil including spreading, leveling, watering and well ramming in layers n exc 25cm in soil ; Complete all as specified and directed by Engineer-in-charge.
Removing excavated material/surplus soil not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meter above starting point ; Complete all as specified and directed by Engineer-in-charge.
Material & Labour in repairs earthing complete with galvanised earth plate electrode 600mm X 600mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 metres below ground level) with top edge of earth plate not less than 1.5metres below normal ground level, connected to GI Wire of size 4mm dia by means of nuts, bolts, check nuts & washers of galvanised iron or steel all as shown on electrical plate No.3 of MES SSR 2009, Part – I (Specifications) and connected to main switch board/LT feeder panel including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in alternate layers with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50mm thick RCC cover in PCC 1:2:4, type B-1, duly reinforced with 6 mm dia mild steel round bars @ 150mm both ways center to center with suitable lifting handle to cover, earth pit made of PCC 1:3:6 type C-1, GI protection pipe light grade 20 mm bore up to 7.5metres length from earth electrode including testing ; Complete all as specified and directed by Engineer-in-charge. NOTE: (i) Earth lead and protection pipe beyond 7.5 m shall be measured and Paid separately. (ii) On testing after completion of job, if desired earth resistance is not obtained, the earthing shall be redone by the contractor without any extra cost to Govt. (iii) Rate quoted shall be inclusive of excavation and earth work and PCC all as specified in the item (iv) Earthing work will be carried out in the presence of MES representative
Material and Labour for distribution board, vertical, made out of sheet metal enclosure (CRCA sheet) dust and vermin proof, double door, VTPN 4 way, 415 volts grade with insulated rated bus bar assembly with isolated neutral bar,door earthing, earth bar IP- 43 protection with poly urithene (PU) gasketing, IK-08 Mechanical impact resistance, door earthing flush to wall, including testing suitable for fixing MCCB, MCB TPN/TP/SPN/SP etc, of , including dismantling of old UNSV one of any type/size from site and making good to disturbe surface wall complete all as directed NOTE FOR SER NO.: MCB DB & MCBs should be of same make as mentioned above.
Supply and Fixing MCCB triple pole and neutral (four pole) 160 Amps, 415 volts, 50 Hz, having thermal setting range 70% to 100% and adjustable magnetic setting and breaking capacity 25 KA including making incoming and outgoing connections including dismantling of old UNSV one of any type/size from site ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof, double door, TPN 4 way, 415 volts grade with 200 Amps insulated rated bus bar with nickel plated brass, isolated neutral bar and door earthing, earth bar IP- 43 protection with poly urithene (PU) gasketing, IK-08 Mechanical impact resistance, flush to wall, including testing suitable for fixing MCB SPN, SP etc, including dismantling of old UNSV one of any size/type from site and making good to disturbe surface wall ; Complete all as specified and directed by Engineer-in-charge. NOTE: Necessary blank plates if required any to cover the blank MCB's place in DB and the rate shall be deemed to included in the quoted rates.
All as per ser item No. 132 above but for SPN 12 way, 240 volts grade with 200 Amps insulated rated busbar ; Complete all as specified and directed by Engineer-in-charge.
All as per ser item No. 132 above but for SPN 4 way ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing MCB of SP 5 to 32 Amps current carrying capacity, 240 V, 10KA 'C' curve fixed in the MCB DB complete with connection testing & commissioning ; Complete all as specified and directed by Engineer-in-charge.
All as per ser item No. 135 above but for MCB SPN 40 to 63 Amps, 415 V grade ; Complete all as specified and directed by Engineer-in-charge.
All as per ser item No. 135 above but for MCB TP 63 Amps, 415 V grade ; Complete all as specified and directed by Engineer-in-charge.
All as per ser item No. 135 above but for MCB TPN 63 Amps, 415 V grade ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Neon LED flexible strip lights of red colour, IP 20 non integral, 220Volt, and fixing in wall/panelling/false ceiling drops including testing ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing NEON LED strip connector, 220 volts for IP 20 non integral flexible LED strip light (Colour RGB) ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing garden light with square shape, integral decorative LED bollard with opal acrylic with IP-65 protection for single compact LED lamp of capacity 1x9Watt LED with all accessories with necessary PCC foundation as directed incl junction box, electrical connection, testing, ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing RUBY LED POST TOP new generation, with high power LEDs as light source of 20/25 watt, 230 Volts, AC, outdoor type for 360 degree indirect light, IP-65 protection with impact and corrosion resistant complete with driver and post-top lamp, energy saving, environmental friendly, long life, aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire suitable for fixing with & incl galvanised iron pipe of suitable dia and size as per site including all accessories complete and necessary electrical connection, testing ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Dusk & dawn roadway luminaries 35 Watt, 230 V AC, 5700K outdoor type with epoxy black powder coated sheet, high pressure die-cast aluminum hosing and heat resistant complete with impact and corrosion resistant including thermal management in multiple optics, PF>95%, THD<10%, Lumen>4500 lm with IP 65/66 protection complete incl connecting wire with flexible PVC insulated copper cables from ceiling rose to fitting including driver, lamp bracket made of 32mm bore galvanised iron light grade pipe made to shape having overall length not exceeding 1.5 mtr, through mild steel clamp of 25mm width and four Nos. nuts, bolts & washers of 12mm dia, 100mm long fixed to wall with all other fittings complete and testing ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing storage electric heater (Geyser), flexible mounting of capacity 25 ltrs, single phase, 240 volts, AC, white colour, with incoloy heating element and PUF insulation, ISI marked BEE 5 star rated complete with high precision & externally adustable capillary thermostat for temp regulation, backup safety overheating capillary therrmal cut out at 95ºC, temperature display, etc., including provn of new suitable holding clamp, MS bolts, grouted to wall and connecting up including 3 core sheathed multi-stranded flexible copper conductor cable connected with 15/16 Amp plug top and provn of water connections with new PVC steel braided inlet/outlet connection pipe 15mm dia, 450mm long with two numbers brass union, NRV of suitable size, check/end nuts with washers, 15mm dia 100mm long nipples (02 Nos) for hot water and cold water connections including writing MES No. and making good to the disturbed surface in cement morter as required and testing ; Complete all as specified and directed by Engineer-in-charge. NOTE: Cost of flexible copper cable of 3 core, PVC steel braided inlet/outlet pipe of 15mm dia, 450mm long with brass union, NRV, check/end nuts, nipples, MS bolts, etc., and minor parts, if any, other than those are not specified in the schedule and required for smooth functioning of geyser will be deemed to be included in the quoted rate
Supply and fixing sub main wiring with 4 runs of 16.0 sqmm single core, multi-stranded PVC insulated, FRLS sheathed cable 1100 Volts grade with copper conductor drawn through and including non metalic PVC conduit, medium grade, not less than 25mm dia, ISI marked, with conduit fittings and accessories not less than 25mm dia concealed in wall/ceiling/floor including 2 runs run of 16.0 Sqmm multistranded PVC insulated FRLS, copper conductor cable as earth continuity conductor and connecting to common earth dolly ; Complete all as specified and directed by Engineer-in-charge. NOTE: Four runs of 16.0 sqmm copper cable and two run of 16.0 sq mm copper cable alongwith non metallic PVC conduit/conduit accessories not less than 25mm dia will be measured as one unit length
All as per ser item No. 145 above but for sub main wiring with 2 run of 6 sqmm & 1 run of 6 sqmm as earth wire ; Complete all as specified and directed by Engineer-in-charge.
All as per ser item No. 145 above but for sub main wiring with 2 run of 4 sqmm & 1 run of 4 sqmm as earth wire ; Complete all as specified and directed by Engineer-in-charge.
Sai Construction Co.
ESS KAY BUILDER
Santokh Singh and Associates
M/S A.R. ENGINEERS & CONTRACTORS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .