Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L2₹12.3 L+₹9,330 (0.72%)Accepted-AOC | L2 | Accepted-AOC Accepted | |
| 2 | L1₹12.9 LRejected-AOC NEW HOSPITAL ROAD UDHAMPUR UDHAMPUR UDHAMPUR UDHAMPUR JAMMU KASHMIR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Rejected-AOC Rejected | |
| 3 | L3₹13.3 L+₹40,913 (3.17%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹13.7 L+₹77,463 (6.01%)Rejected-AOC 24 SHANTI BHAWAN DHARI ROAD BELTARI PITHORAGARH UTTARAKHAND 262520 | PITHORAGARH | UTTARAKHAND | 262520 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹20.0 L+₹7.1 L (55.3%)Rejected-AOC G 704 SUNCITY HEIGHTS LADHOUT ROAD SECTOR 36A ROHTAK HARYANA 124001 INDIA | ROHTAK | HARYANA | 124001 | L5 | Rejected-AOC Rejected |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
3 Jun 2020, 6:00 pmClosed
SHUBHAM PRAKASH
GE (NORTH) UDHAMPUR
GE/U(N)-18/2020-21 REPAIR/REPLACEMENT OF ALUMINIUM WIRING INCLUDING INTERNAL FITTING AND FIXTURE AND OTHER CONNECTED WORKS OF MD ACCN AND OTM ACCN OF AMSD FHO AND CH(NC) UNDER GE (NORTH) UDHAMPUR
2020_MES_342625_1
GE/U(N)-18/2020-21
Open Tender
Civil Works
Item Rate
180 days
UDHAMPUR
CLASS E
8 documents required · 8 mandatory
₹500
GE (NORTH) UDHAMPUR
₹36,000
Yes
17 Jun 2020
4 May 2020
5 Jun 2020
4 May 2020
3 Jun 2020
19 May 2020
Amount
Taking down carefully the existing Copper/ Aluminium point wiring of any size and type by disconnecting from the either terminals complete with switches, sockets, ceiling rose, regulators, bell etc by unscrewing and removing materials to store for keeping in safe custody for re-use or for taking credit and making good to disturb surface of walls, floors etc., complete all as specified and directed by Engr -in- charge. Note : (i) Old dismanteled wiring and accessories (other than reuse) will be contractors property and credit will be charged against schedule of credit.
Taking down carefully by unscrewing from boards / outlet boxes fittings and fixture such as, LED bulk head fitting, LED tube light fitting etc. for re use at site or carrying to the store (serviceable fitting shall be reuse) all as specified and as directed by engineer in charge.
Taking down Old Serviceable/unserviceable MCB DB and VTPN any type/size etc after disconnecting (serviceable DBs /MCBs shall be reuse), complete all as specified and directed by Engr -in-charge.
Point wiring for One light point controlled by one one way switch 5 Amp with 1.5 Sqmm single core multi standed copper conductor FRLS insulated and unsheathed heavy duty cable in colour code including contineous earth wire with cable of size 1.5 sqmm copper conductor flexible FRLS insulated drawn into and including concealed PVC rigid conduit of not less than 20mm dia , ISI marked terminated into annealed steel terminal boxes including 3.00 mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc, complete all as specified and directed by the Engr-in-charge.
Point wiring with 1.5 Sq. mm PVC Insulated unsheathed FRLS multistranded copper conductor, medium grade ISI meraked drwan into and including PVC concealed conduit with all accessories from terminal box to junction of ceiling and wall and rest of circuit conductor wire drwan in to and including suraface PVC rigid non metalic conduit for one ceiling fan point controlled by one switch with and also including 1.5 sqmm continious earth wire connected to common earth dolly, complete all as specified and directed by Engr -in-charge.
All as per item No. 04 above but for bell / buzzer on independent board controlled by one push button bell switch, complete all as specified and directed by Engr -in-charge.
All as per item Srl No. 04 herein before but for 3 pin socket outlet 5 Amp on same board, complete all as specified and directed by Engr -in-charge.
All as per item No. 04 above but for one 5 Amps socket outlet on independent board.
All as per item No. 04 above but wire size 2x2.5 Sqmm to controlled the 3 pin 5 / 15 Amps socket outlet on independent board and providing earth continuity wire using PVC insulated, FRLS 1100 volts grade un sheathed single core stranded copper conductor cable of size 2.5 Sqmm.
All as per item No. 04 above but controle by 2 Nos.of two way switch, complete all as specified and directed by Engr -in-charge.
Point wiring with multistranded copper conductor cable, PVC insulated and unsheathed (FRLS) size 1.5 sqmm drawn in and incl PVC casing and caping with fixing accessories, to be fixed on wooden gutties or plastic rawal plug, for one light /fan/controlled by one switch with thickness not less than 1.25mm annealed steel boxes concealed on wall with and including 3mm thick laminated backlite sheet, complete all as specified and directed by Engr -in-charge.
All as per item No 11 above but for two way point wiring , complete all as specified and directed by Engr -in-charge.
All as per item No 11 above but for one 3/5 pin socket 5 Amp on same board.with cable1.5 sqmm size, complete all as specified and directed by Engr -in-charge.
All as per item No 11 above but for one 3/5 pin socket 5 Amp on independent board.with cable1.5 sqmm size, complete all as specified and directed by Engr -in-charge.
All as per item No 11 above but for 3/5 pins socket outlet 15 Amps independent with 2.5 sqmm incl continous earthing with multistandred copper conductor PVC insulated unsheathed size 2.5 Sqmm complete all as specified and directed.
All as per item No. 11 above but for bell / buzzer on independent board controlled by one push button bell switch.
Switch Piano flush type single pole 5 Amps One way, all as specified and directed by Engineer- in - Charge.
Fixing only serviceable Switch Piano, flush type, One way, single pole, 5 Amps, obtained from item no 01 as above complete all as directed by Engineer- in - Charge.
Switch Piano flush type single pole two way 5 Amps, complete all as specified and directed by Engr -in-charge.
Fixing only serviceable Switch Piano, flush type, two way, single pole, 5 Amps, obtained from item No-01 as above complete all as directed by Engineer- in - Charge.
Socket outlet Two in one, 3/5 Pin piano type 5 Amp flush type complete all as specified and directed by Engineer- in - Charge.
Fixing only serviceable Two in one, 3 Pin, 5 Amp flush type socket outlet obtained from item No-01 as above, complete all as directed by Engineer- in - Charge.
Switch Piano type single pole 16/20 Amps One way, complete all as specified and directed by Engineer- in - Charge.
Fixing only serviceable Switch Piano, flush type, One way, single pole, 15 Amps, obtained from Item No -01 as above complete all as directed by Engineer- in - Charge.
Socket outlet Two in one, 3/5 Pin piano type 10 Amp and 20 Amp flush type complete all as specified and directed by Engineer- in - Charge.
Fixing only serviceable Two in one, 3 Pin, 5 and 15 Amps, flush type socket outlet obtained from item No-01 as above complete all as directed by Engineer- in - Charge.
Ceiling rose, 3 terminal, PVC / polycarbonet, isolated body complete all as specified and directed by Engineer - in - Charge.
Fixing only serviceable Ceiling rose, 3 terminal, PVC / polycarbonet, isolated body obtained from item No-01 as above complete all as directed by Engineer - in - Charge.
Electric bell (Ding dong) AC 230/250 volts grade single pole ISI marked, complete all as specified and as directed by engineer in charge
Fixing only serviceable Calling bell, obtained from item No-01 as above, complete all as directed by Engineer- in - Charge.
Switch piano flush type for bell Push 5 Amps, complete all as specified and directed by Engineer- in - Charge.
Fixing ony serviceable Push bell switch piano, flush type, white colour, obtained from Item No-01 as above complete all as directed by Engineer- in - Charge.
Electronic type fan regulator Stepped type, 240Volt flush type suitable for 1200/1400mm sweep ceiling fan, ISI marked, complete all as specified and directed by Engineer- in - Charge.
Fixing only serviceable Stepped type, electronic fan regulator, flush type on the existing phenolic laminated sheet etc. as obtained from Item No-02 as above, complete all as directed by Engineer- in - Charge.
Fixing only serviceable light fittings any type as obtained against item No 2, complete all as directed by Engineer- in - Charge.
Taking down fan, ceiling cable end, dismantling blades and kept in safe custody for refixing on same location, complete all as directed by Engineer- in - Charge.
Hanging /fixing only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan obtained from item no 36, complete all as directed by Engineer- in - Charge.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4 mm dia galvanised earth lead wire by means of bolts, nuts, check nuts and washers of galvanised standard iron or steel all as specified or indicated in electrical plate no 3 of MES Part-I, fixed in replacement, complete all as specified and directed by Engr-in-charge. Including testing on completion including the material and labour of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified. (e) 15 mm nominal bore light grade GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : (a) On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge. (b) The contractor shall quote his rate considering taking down cost of existing unserviceable earthing.
Earthing in repair complete with copper plate earth electrode 60cmX60cmx3.15 mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level ) with top edge of the plate not less than 1.5m below normal ground level connected to earth lead by means of bolts nuts and washers of GI steel and including earthing pit charcoal, common salt, 20x 3 mm copper strip, 20mm GI medium grade watering pipe 15mm bore light grade protection pipe 5 Mtr length with wire mesh and funnel PCC pit in PCC 1:2:4 type B-1 using 20mm graded stone aggregate, angle iron frame and RCC cover and earth work complete all as shown in electrical plate No.3 of SSR -2009(Part-1), complete all as directed by Engineer- in - Charge.
Sub main wiring with two run single core 4 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100 V including 25 mm dia PVC concealed conduit medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 4 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion etc complete all as directed. Note: Two runs of 4sqmm and one run of 4 sqmm cable and one run of PVC conduit/ casing capping shall be measured as one RM, complete all as directed by Engineer- in - Charge.
All as per item No. 40 herein before but with 6 sqmm pvc copper conductor cable through pvc conduit ISI marked with 6 sqmm copper conductor cable as earth contiunity conductor, complete all as directed by Engineer- in - Charge.
All as per item No. 40 herein before but with 10 sqmm pvc copper conductor cable through pvc conduit ISI marked with 10 sqmm copper conductor cable as earth contiunity conductor, complete all as directed by Engineer- in - Charge.
Sub main wiring with two run single core 4 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100 V including 25 mm dia PVC surface conduit/PVC casing caping medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 4 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion etc, complete all as directed by Engineer- in - Charge. Note: Two runs of 4sqmm and one run of 4 sqmm cable and one run of PVC conduit/ casing capping shall be measured as one RM
All as per item No. 43 herein before but with 6 sqmm pvc copper conductor cable through pvc conduit ISI marked with 6 sqmm copper conductor cable as earth contiunity conductor.
All as per item No. 43 herein before but with10 sqmm pvc copper conductor cable through pvc conduit ISI marked with 10 sqmm copper conductor cable as earth contiunity conductor.
Switch Piano flush type single pole two way 5 Amps fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
Switch Piano flush type single pole 5 Amps one way fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
Switch piano flush type for bell Push 5 Amps fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
Socket outlet Two in one, 3/5 Pin piano type 5 Amp flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
Socket outlet Two in one, 3/5 Pin piano type 5 Amp and 15 Amp flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
Switch Piano type single pole 16/20 Amps One way, fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
Switch socket combination piano type 5 pin 5 Amps flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
Switch socket combination piano type 6 pin 16 Amps flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
Switch socket combination Box type 5 pin 5 Amps flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
Switch socket combination Box type 6 pin 16 Amps flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
Ceiling rose, 3 terminal, PVC / polycarbonet, isolated body fixed in replacement, complete all as specified and directed by Engineer - in - Charge.
Electronic type fan regulator Stepped type, 240Volt flush type suitable for 1200/1400mm sweep ceiling fan, ISI marked fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
Electric bell(Ding dong) AC 230/250 volts grade single pole ISI marked fixed in replacement, complete all as specified and as directed by engineer in charge.
Fixing only serviceable MCB DB of any type and capacity obtained from Item No 03 complete all as specified and directed by engineer incharge.
Sheet metal enclosure double door single pole and neutral 240 Volts for DB's when MCBs to be used 8 way with 200 amp rated bus bar with IP-43 protection fixed in replacement, complete all as specified and as directed by engineer in charge.
All as per srl item No 60 above but 4 way fixed in replacement, complete all as specified and as directed by engineer in charge.
All as per srl item No 60 above but 12 way, complete all as specified and directed by the Engr-in-Charge.
Sheet metal enclosure VTPN 4 way 415 volt 250 Amp rated bus bar double door type with suitable for mounting MCCB for incomer and MCBs for outing without MCCB and MCB IP-43 protection fixed in repair, complete all as directed by Engr-in-Charge.
All as per srl item No 63 above but 6 way, complete all as specified and directed by the Engr-in-Charge.
All as per srl item No 63 above but 8 way, complete all as specified and directed by the Engr-in-Charge.
MCCB 4 pole, 415 volt, Adjustable type 100 Amp with breaking capacity 16 KA fixed in replacement, complete all as specified and as directed by engineer in charge.
MCCB 4 pole, 415 volt, Adjustable type 160 Amp with breaking capacity 16 KA fixed in replacement, complete all as specified and as directed by engineer in charge.
MCCB 4 pole, 415 volt, Adjustable type 200 Amp with breaking capacity 25 KA fixed in replacement, complete all as specified and as directed by engineer in charge.
MCCB 4 pole, 415 volt, Adjustable type 250 Amp with breaking capacity 25 KA fixed in replacement, complete all as specified and as directed by engineer-in-charge.
MCB SPN 40 to 63 Amp 240V, 50Hz, 10kA 'C' series including Connection and testing for lighting and other domesitc loads incl necessary copper lugs etc fixed in replacement, complete all as specified and as directed by engineer in charge.
MCB SP 6-32 Amps 'C' series Connection and testing fixed in replacement, complete all as specified and as directed by engineer in charge.
MCB SP 40-63 Amps 'C' series Connection and testing fixed in replacement, complete all as specified and as directed by engineer in charge.
Fixing only serviceable MCB SPN/SP any capacity obtained from item no 03 as above all as specified and as directed by engineer in charge.
Modular fan step regulator 120W 02 module including taking down unserviceble one all as specified and as directed by engineer in charge.
Modular switch 01 way 06A, 01 module including taking down unserviceble one all as specified and as directed by engineer in charge.
Modular switch 01 way 16A, 01 module including taking down unserviceble one all as specified and as directed by engineer in charge.
Modular bell push flush type 6A, 01 module including taking down unserviceble one all as specified and as directed by engineer in charge.
Modular socket, 6A-2/3 pin, 02 module including taking down unserviceble one all as specified and as directed by engineer in charge.
Modular socket, 6A/16A-2/3 pin, 02 module including taking down unserviceble one all as specified and as directed by engineer in charge.
PVC rectangular block for mounting switches, sockets, fan regulator etc. of size 200x150x50mm deep including making necessary cutting fixed in replacement, complete all as specified and as directed by engineer in charge.
PVC rectangular block for mounting switches, sockets, fan regulator etc. of size 250x200x50mm deep including making necessary cutting fixed in replacement, complete all as specified and as directed by engineer in charge.
3 mm thick plastic laminated ebonite sheet cover of size 200x150mm including cutting /finishing or making hole for mounting of switches, sockets, regulators etc fixed in replacement, complete all as specified and as directed by engineer in charge.
3 mm thick plastic laminated ebonite sheet cover of size 250x200mm including cutting /finishing or making hole for mounting of switches, sockets, regulators etc fixed in replacement, complete all as specified and as directed by engineer in charge.
Slim linear LED lighting fixture 4/5W watt LED batten, with full base of extruded poly carbonate isolated driver, complete making all connection from ceiling rose to fittings including testing fixed in replacement, complete all as specified and as directed by engineer in charge. Make of LED -Syska Cat No:SSK-SQ0401/Wipro Cat No : D530565/C&S Cat No: LTTBIF5WLED/W/ Havells: Cat No: LHEXBXPNIN1W005
Slim linear LED lighting fixture 20 Watt LED batten, P.F greater than 0.9, input voltage range from 90 Volts to 280Volts with full base of polycarbonate extruded section acting as a heat sink with closed back isolated driver complete making all connection using 1.5sqmm copper conductor multistranded PVC insulated 2 core flexible cable with from ceiling rose to fitting fixed in replacement, complete all as specified and as directed by engineer in charge. Make : Syska Cat No: SSK-SQ2001/Havells Cat No: LHEXBXPNIN1W020/ or equivallent to Wipro
LED Bulk head (6500K) fitting of 09/10 Watt surface mounting type extruded aluminium body with diffuser complete with testing fixed in replacement, complete all as specified and as directed by engineer in charge. Make:Syska Cat No: SSK-BH-9W /Wipro Cat No : DA11265/Crompton :Cat No: LBHE-10-DL /Havells: Cat No: RUGBYNEONFT10WLED860SSYMTOPC
Decorative ultra slim linear polycarbonate Extruded LED lighting fixture 10/12 Watt LED of input voltage AC 220V-240V, 50 Hz with colour tempetrature 6500K more than 1080 lumens of IP 20 complete making all connection using 1.5 sqmm copper conductor multistranded PVC insulated twin core flexible cable from ceiling rose to fitting fixed in replacement, complete all as specified and as directed by engineer in charge. Make Syska Cat No: SSK-SQ1201 Wipro Cat No : D531065/Havells: Cat No: LUMILINEPLUSBS10WLED865SPCSS/ Philips Cat No : BN 021 LED10S- 6500 PSU GR S1
Ultra modern designed aechitectural 2x2 LED, 6500K, 40 watt luminaire which provides soft light and glare free symmetrical illumination (VENUS NEO), fixed in replacement, complete all as specified and as directed by engineer-in-charge. Make of LED -Wipro as per ordering code D414065 or equivalent model of Havells or CG
Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings fixed in replacement, complete all as specified and as directed by engineer-in-charge.
LED garnet 18 W NR lamp,4 pin type, 6500K, as per sample fixed in replacement, complete all as specified and as directed by engineer-in-charge.
LED T8 retrofit tube rod lamp 22W, 6500K, as per sample fixed in replacement, complete all as specified and as directed by engineer-in-charge.
MCB TPN 63 Amp, 415 Volts- C curve of 10kA fixed in replacement, complete all as specified and as directed by engineer-in-charge. Make : C&S Cat No: CSMBS3C63N/ IndoAsian Cat No 810098/ Havells
Isolator 4 Pole 100 Amp, 415 Volts fixed in replacement, complete all as specified and as directed by engineer-in-charge. Make : C&S Cat No: CSMBS4ISO100/ IndoAsian / Havells
Isolator 4 Pole 125 Amp, 415 Volts fixed in replacement, complete all as specified and as directed by engineer-in-charge. Make : C&S Cat No: CSMBS4ISO100/ IndoAsian / Havells
Plug and socket DBs, single pole and neutral enclosure with a two pin earth plug and socket with one single 20 Amps, 240 volts MCB fixed in replacement, complete all as specified and as directed by engineer-in-charge.
Modular white cover plate with frame 3 module fixed in replacement, complete all as specified and as directed by engineer-in-charge.
Modular white cover plate with frame 4 module fixed in replacement, complete all as specified and as directed by engineer-in-charge.
Modular white cover plate with frame 6 module fixed in replacement, complete all as specified and as directed by engineer-in-charge.
Modular white cover plate with frame 8 module fixed in replacement, complete all as specified and as directed by engineer-in-charge.
Rigid non - metalic PVC casing caping of 25/12mm inclusive of all elbow, tees,etc fixed in replacement, complete all as specified and as directed by engineer-in-charge.
PVC conduit medium grade 20 mm dia ISI marked with all accessories such as Tees, elbows, junction boxes etc fixed in replacement, complete all as specified and as directed by engineer-in-charge.
All as per srl item No 101 above but 25mm, complete all as specified and directed by the Engr-in-Charge.
Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed conduit wiring, etc, and making good, cutting not exc 10 cm girth, complete all as specified and directed by the Engr-in-Charge.
Disconnecting all Electrical connection from MCB DB TPN/Wall Mounted Panel Box for reconnecting the same with providing proper Copper Bottle Lugs of suitable size and removing the burnt out internal wiring of DB/Panel complete with providing PVC Flexible conduit for Hanging wire, complete all as specified and directed by the Engr-in-Charge. Note : Replacement Burnt out MCBs of any type/size may be measured and paidseparately under relavent Items
Taking down/removing existing damaged cable connection from MCB DB/Wall Mounted Panel Board by making cutting chases on wall/ floor to extend the shorten UG cable of any type/size from Loop and making fresh to reconnect the same with suitable aluminium lugs complete including distribute the load equally on each phase, complete all as specified and directed by the Engr-in-Charge. Note : Cutting of Wall /Floor shall be measured and paid separately.
M&L for Cutting of hard standing n.exc 45 Cm defth, and n.exc 30 Cm width for taking out/laying UG Cable including making good disturbed surface as per existing, complete all as specified and directed by the Engr-in-Charge.
HIMALAYA ENTERPRISES
M/S Builders Indias
m/s shanti trading company
Bansal and Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .