Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.5 LAccepted-AOC 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG 793009 MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹30.2 L+₹1.6 L (5.67%)Rejected-Finance NALIAPOOL BAZAR ROAD NEAR GABHARUPATHAR RAILWAY COLONY DIBRUGARH DIST ASSAM 786001 | DIBRUGARH | DIBRUGARH | ASSAM | 786001 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹30.4 L+₹1.8 L (6.12%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹30.4 L+₹1.8 L (6.29%)Rejected-Finance AT ROAD MES TINALI PO CHABUA DISTT DIBRUGARH ASSAM 84 | CHABUA | DIBRUGARH | ASSAM | 786102 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹31.0 L+₹2.4 L (8.46%)Rejected-Finance AT ROAD NEAR MES TINALI PO CHABUA DIST DIBRUGARH ASSAM | L5 | Rejected-Finance Being L5 |
Tender Value
₹28.5 L
EMD Value
₹57,000
Closing Date
11 Jan 2020, 6:00 pmClosed
GE (AF) Mohanbari
GE (AF) Mohanbari, Mohanbari-Post, Dibrugarh-Dist, Assam-786012
Provision of certain Electrical Work of Capital Major revenue and Minor Works at AFS STN Dinjan and Mohanbari under GE(AF) Mohanbari
2019_MES_296905_2
NIT No . 8001/175/01/E8 OF 2019-2020
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AFS Mohanbari and Dinjan
As per tender documents
9 documents required · 9 mandatory
₹500
GE (AF) Mohanbari
₹57,000
Yes
14 Mar 2020
2 Jan 2020
13 Jan 2020
2 Jan 2020
11 Jan 2020
6 Jan 2020
Amount
Supply fixing and testing LED street light epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws alongwith secondary optics and individual LED's for better light distribution, input voltage 140-280 Volts, delivering lumen equal to/greater than 10200 lumen, system wattage 120 Watt, Ingress protection IP-66 and integrated driver with 5KV internal and 10 KV external surge protection including all acessories complete all as specified and directed by engr-in-charge.
Supply fixing and testing LED street light epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws alongwith secondary optics and individual LED's for better light distribution, input voltage 140-280 Volts, delivering lumen equal to/greater than 10200 lumen, system wattage 70 Watt, Ingress protection IP-66 and integrated driver with 5KV internal and 10 KV external surge protection including all acessories complete all as specified and directed by engr-in-charge.
Supply fixing and testing of flood light luminaries LED type with minimum 140 lumens per watt, integral driver, IP 66, Class I with C clamps mounting and LM6 pressure die cast housing with hight efficiency glass cover system power 90 watts and making necessary electrical connection with suitable size PVC insulated copper multi stranded cable, all as specified and directed by engr-in-charge.
Supply & fixing loop in loop out Polycarbonate Junction box in accordance with IEC 60670-22 of size 200 mm x 160 mm x 98 mm , suitable for LT cable 10 sqmm with front openable hinged cover and locking arrangements with IP 65 degree of protection, dust proof, water tight, shock proof, fire retardant with internally embedded gasket fitted with heat treated bakelite terminal block and PVC glands for cable entry complete with electrical connection fixed to pole with suitable size FI clamp nut bolts and washer including duty painted with powder coated paint complete all as specified and directed by engr-in-charge.
Supply and fixing/laying XLPE insulated GI wire/strip armoured electric power cable (Heavy duty) with stranded aluminium conductor 1100 volts grade, cross sectional area 10 Sqmm , 4 core laid in trench /poles/on wall/floor including nut and bolts, clamps as required at site all as specified and as directed by engr-in-charge. (Excavation, earth work, sand cushioning, protection brick and pipe shall be measured and paid separately under appropriate items).
Supply and fixing/laying XLPE insulated GI wire/strip armoured electric power cable (Heavy duty) with stranded aluminium conductor 1100 volts grade, cross sectional area 16 Sqmm , 2 core laid in trench /poles/on wall/floor including nut and bolts, clamps as required at site all as specified and as directed by engr-in-charge. (Excavation, earth work, sand cushioning, protection brick and pipe shall be measured and paid separately under appropriate items).
Supply and fixing/laying XLPE insulated GI wire/strip armoured electric power cable (Heavy duty) with stranded aluminium conductor 1100 volts grade, cross sectional area 35 Sqmm , 3.5 core laid in trench /poles/on wall/floor including nut and bolts, clamps as required at site all as specified and as directed by engr-in-charge. (Excavation, earth work, sand cushioning, protection brick and pipe shall be measured and paid separately under appropriate items).
Supplying and fixing galvanised mild steel pipe/tubing, medium grade complete with all fittings of 40 mm bore, laid in floor, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers complete all as specified and directed by engr-in-charge.
Supplying and fixing galvanised mild steel pipe/tubing, light grade complete with all fittings of 50 mm bore, laid in floor, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers complete all as specified and directed by engr-in-charge.
M & L for drawing of 3 core 1.5 Sqmm copper conductor cable and incl ERW conduit of bore dia. 15 mm duly painted with alluminium paint incl MS clamps fixed required to fix with the pole complete all as directed by engr-in-charge.
Supply and fixing in repair GI bracket for street light made out of 40 mm dia GI pipe medium grade 1.2 metre in length bend in shape as required including necessary MS flat iron clamp, nuts and bolts etc complete all as specified and directed by engr-in-charge.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth; for trench of cable etc and getting out in Soft/loose soil, making the surface plain complete all as specified and as directed by engr-in-charge.
Material and labour for sand cushioning for protection of underground cable consolidated and compacted with clean dry sand all as specified and as directed by engr-in-charge.(Compacted thickness shall only be measured and paid).
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in Soft/loose soil complete all as specified and as directed by engr-in-charge.
Removing excavated material to a distance n.exc 50 mtr and depositing where directed at level n.exc 1.5 mtr above the starting point all as specified and as directed by engr-in-charge.
Material and labour for well burnt bricks having crushing strength 75 kg/sqcm best quality locally available laid flat, dry in trenches for cable protection complete all as specified and as directed by engr-in-charge.
Material and labour point wiring for wall mounted/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FRLSH cables in and including suitable size PVC casing and caping (ISI marked) , including pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 1.5 sqmm nominal cross sectional area multistranded copper conductor FR PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed by engr-in-charge.
Supply and fixed switch socket combination 2 in 1 , 5 pin , 5 Amps flush type universal(ISI marked) colour matching with surrounding surface.controlled by one switch complete all as specified and directed by engr-in-charge.
Supply and fixed switch piano flush button single pole one way 6 amps, 230 Volts including connection complete all as specified by engr-in-charge.
Supply and fixed heavy duty exhaust fan, 230 volt single phase having metal blade 450 mm sweep 1400 RPM with louvers including all accessories and necessary electrical connection with suitable size PVC insulated copper multi stranded cable, including cutting and making good the wall surface complete all as specified and directed by engr-in-charge.
Supplying and fixing wall mounted fan of 400 mm sweep jerk free oscillation and smooth running , 220 to 240 Volts, AC , 50 Hz, suitable for movement complete with accessories, 3 Nos polycarbonate blade having areodynamically designed and balanced, complete all as specified by engr-in-charge.Make: Havells(Model-sameera)
Supplying, transporting, erecting and fixing Steel tubular swaged poles type 410 SP-31 ( 9.0 metres long) complete with cast iron base plate, finial, taper plug, bolts, nuts and screws as specified, including necessary excavation and earth work , PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C2 around poles and PCC 1:3:6 type C1 as in plinth block , disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, painting steel tubular poles exposed surafces with Aluminium paint two coats over one coat of red oxide primer and providing 300 mm wide bands (3 bands/ straps with synthetic enamel paint and 2 bands with Black bituminous paint ) from plinth block and numbering of poles , painting embedded portion of poles with one coat of bituminous paint complete all as specified and directed by engr-in-charge.
Supply and fixing for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 20 mm x 3 mm thick, copper strip using porcelain clit/post insulators, complete all as specified and directed by engr-in-charge.
Supply and fixing for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 32 mm x 6 mm thick, copper strip using porcelain clit/post insulators, complete all as specified and directed by engr-in-charge.
Supply and fixing for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 32 mm x 6 mm thick, galvanised iron strip using porcelain clit/post insulators, complete all as specified and directed by engr-in-charge.
Supply, fixing and testing of Early Streamer Emission (ESE) type lightening arrestor Level 4 having Radius of Protection 89 mts with wheather proof encloser as per NFC 17-102- 2011 having base plate and GI mast of 4.5 mtrs (It should be fixed on 9 m pole) ,ESE Flange and Lightning Arrester Accessories, copper strip of 20 mm X 3 mm about 10 m length and Copper Bonded Rod 17.2 mm Dia 2 Mtrs long with U Bolt Clamp - Earthing Compound Carbolite 25 Kg Bag - Eco Friendly rust proof heavy duty weather proof Polyethylene Earth Pit Chamber - 3 Ton Capacity complete all as specified and directed by engr-in-charge.
Supply, installing, commissioing and testing , split type Air Conditioner of capacity 2 TR with with hermatically sealed unit complete with dual system i.e. Cooling and with PCB and remote operation on (R-410 A refrigerant ), built in air ioniser and plasma filter for better indoor air quality, electric driven , suitable for working on 230 volts, single phase, 50 Hz supply, (4 STAR Rating invertor type) complete including providing required copper piping, insulation etc, cutting of wall, powder coated steel brackets and making good disturbed surface of wall etc and remote operation complete all as specified and directed by engr-in-charge.
Supply, installing, commissioing and testing , split type Air Conditioner of capacity 1.5 TR with with hermatically sealed unit complete with dual system i.e. Cooling and with PCB and remote operation on (R-410 A or R-32 refrigerant ), built in air ioniser and plasma filter for better indoor air quality, electric driven , suitable for working on 230 volts, single phase, 50 Hz supply, (4 STAR Rating invertor type) complete including providing required copper piping, insulation etc, cutting of wall, powder coated steel brackets and making good disturbed surface of wall etc and remote operation complete all as specified and directed by engr-in-charge.
Supply and fixed 5kVA automatic Voltage stabliser, automatic operation, electronic, single phase, naturally air cooled, indoor type wall mounted, designed to give output voltage 230V + 2.5% at input range between 170 to 250 Volts complete all as specified by engr-in-charge.
Supply and fixed 4kVA automatic Voltage stabliser, automatic operation, electronic, single phase, naturally air cooled, indoor type wall mounted, designed to give output voltage 230V + 2.5% at input range between 170 to 250 Volts complete all as specified by engr-in-charge.
Material and labour for submain wiring comprising two single core, 6 sqmm nominal cross sectional area multistranded copper conductor cable, FRLSH PVC insulated unsheathed 1100 Volts grade drawing in and including PVC conduit 1mm thickness and fittings on surface complete including 6 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified by engr-in-charge. ( Note :- Extra length of cables/ wire required for connection to MCB shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly)
Material and labour for submain wiring comprising two single core, 1.5 sqmm nominal cross sectional area multistranded copper conductor cable, FRLSH PVC insulated unsheathed 1100 Volts grade drawing in and including PVC conduit 1mm thickness and fittings on surface complete including 1.5 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified by engr-in-charge. ( Note :- Extra length of cables/ wire required for connection to MCB shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly)
Supply and fixed epoxy powder coated sheet metal enclosures with socket plug top and MCB , Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB, 20 Amps, 240 Volts, 'C' series current carrying capacity 10 KA , including necessary connection complete all as specified and directed by engr-in-charge.
Supply and fixed in repairs MCB SP, 5 to 32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs including necessry connection complete all as specified and directed by engr-in-charge. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
Supply and fixed in repairs MCB SPN 5-32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed by Engr-in-charge by engr-in-charge. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
Supply and fixed in repairs epoxy powder coated sheet metal enclosure for DBs, single door (when MCBs to be used), Single pole and neutral 240 V, 2 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact including MCB SPN 20 Amps.complete all as directed by engr-in-charge.
Supply and fixing 3-Phase submersible Monoblock pump set of capacity 5 HP, suitable for 415V, suitable for open well, discharge of 6.5-10 LPS at 24-40 Metre head and complete with submersible cable 10 Sqmm 3 core minimum 25 RM complete all as specified and directed by Engr-in-charge.
Supply & fixing on load change over switch four pole 63 amp 415 volt 50 Hz including connection complete all as specified by Engr-in-charge.
S & F Direct On Line Submersible Pump Starter fully automatic suitable for 415V , AC capacity for 6.0 HP Motor.
Supply and fixing test point terminal block made of gun metal or phosphorous bronze, size 75mm x 75mm x 25 mm thick, drilled and screwed including 3 Nos. 8 mm dia. 25 mm long hexagonal head screws, including MS box 2 mm thick of suitable size for protection of test point terminal,complete all as specified and directed by engr-in-charge.
Supply and fixing air termination, single pointed, copper rod 12mm dia and 300mm long fixed on copper strip/GI for earth conductivity to ground complete all as specified and as directed by engr-in-charge.
Material and labour for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm, thick buried directly in ground( earth pit not less than 2.25 mtrs deep below normal ground level )with the top edges of plate not less than 1.5 mtrs below normal ground level connected to GI strip of size 32 mm x 6mm thick by means of GI nuts, bolts check nuts and washers earth lead protected by 15mm dia GI pipe light grade and connected to main distribution board/earthing test point all as shown in electrical plate No 5 of SSR part 1 and all as specified including testing on completion. Notes:-The unit rate also including for excavation, earth work in any type of strata, plain cement concrete 1:3:6 mix, Type C1 pit, 40 mm thick RCC 1:2:4 mix , type B1 cover reinforced with 8mm dia TMT bars @150mm C/C both ways ,GI funnel with GI watering pipe 20 mm dia medium grade, wire mesh, protection pipe 15mm dia GI pipe light gde for earth lead upto 7.50m longcomplete all as specifoed and as directed by engr-in-charge. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Material and labour for Chemical earthing complete with copper earth plate electrode of size 900 mm x 600 mm x 5 mm buried directly in ground (earth pit not less than 2.25 m deep below the normal ground level) with top edge of plate not less than 1.5m below normal GL connected to copper earth strip 32x6mm,all as shown on electrical plate No. 3 of SSR Part - 1, using 5 Nos alternate layers of charcol and salt crystal and a final layer of Magnesium sulphate of 5 cm thickness to be provided and connected to earth test point including 25 mm dia GI med grade pipe for watering with funnel and wire meshed and 63 mm dia GI light grade pipe for protection of earth strip and providing water supply connection from nearest water supply point and testing complete all as specified and as directed by engr-in-charge. Note : (i) The unit rate shall deemed included for earth work in hard / dense soil, PCC (1:2:4) type B-1 chamber, RCC (1:1.5:3) cover 50mm thick reinforced with 8mm dia TMT bars @ 150mm c/c both ways, funnel with watering pipe 25mm dia medium grade, GI protection pipe light grade 63mm dia, and wire mesh complete in addition to item No. 1 (a) to (e) of preamble (notes) under sub - heading earthing, specified on SI. page No. 422 of SSR Part-II. (ii) The earthing pit should be provided with proper earth pit and pit cover. Pit cover should be painted with synthetic enamel paint of approved colour and pit number to be marked on a GI plate above 45 cm from GL as per colour code followed in AF Station. (iii) If the desired earth registance is not achive during testing as per IS the complete earthing shall be carried out by the contractor at his own cost and no extra claim shall be admissable.
HIND CONSTRUCTION
FREEZCON
M/S R G Construction
M/S RK Trading
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .