Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.3 LAccepted-AOC 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC Being lowest and competitive | |
| 2 | L2₹48.3 L+₹1.0 L (2.15%)Rejected-AOC E 30 RAJIV NAGAR BEGAMPUR NEW DELHI 110086 | NEW DELHI | NEW DELHI | DELHI | 110086 | L2 | Rejected-AOC Neither lowest nor competitive |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
1 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (Central) Delhi Cantt
GE (Central) Delhi Cantt
PROVN OF CERTAIN SANCTION WORKS IN THE AREA OF AGE B/R-I AND AGE E/M UNDER GE (CENTRAL) DELHI CANTT-10
2021_MES_410188_1
GE/C-76/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE (Central) Delhi Cantt
As per NIT
9 documents required · 9 mandatory
₹500
GE (Central) Delhi Cantt
₹98,000
Yes
6 Mar 2021
6 Jan 2021
3 Feb 2021
6 Jan 2021
1 Feb 2021
20 Jan 2021
6 Jan 2021 - 20 Jan 2021
60 days
Amount
Surface excavation n exc 30 cm deep and averaging 20 cm deep and getting out complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches in (soft/loose soil) n exc. 1.5m wide and n exc 1.5 m in depth for foundation etc. and getting out complete all as specified and directed by Engineer-in-Charge.
M&L for providing plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation and mass concrete complete all as specified and directed by Engineer-in-Charge.
M & L cement concrete M-25 desigh mix (using 20mm graded aggregate) for foundations, including rafts, footings, foundations beams, plinth beams, bases for columns etc complete all as specified and directed by Engineer-in-Charge.
M & L cement concrete M-25 desigh mix (using 20mm graded aggregate) for slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slab and in shelves and this like complete all as specified and directed by Engineer-in-Charge.
M & L cement concrete M-25 desigh mix (using 20mm graded aggregate) for columns, pillars, piers, post and strut complete all as specified and directed by Engineer-in-Charge.
M & L cement concrete M-25 desigh mix (using 20mm graded aggregate) for beams, cantilivers, beressummers, lintels over 1.5m span complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete M-25 Design Mix ( using 20mm graded aggregate) for chajja above windows complete all as specified and directed by Engineer-in-Charge.
M & L for formwork to sides of concrete , foundations, footings, bases of columns, rafts and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work for rough finished surface complete all as specified and directed by Engineer-in-Charge.
M & L for formwork to soffits of suspended slabs such as roof slabs, floors slabs, landings and similar work not exceeding 200mm thick (horizontal or sloping) for rough finished surface complete all as specified and directed by Engineer-in-Charge.
M & L for formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantiliver shelves etc.for fair finished surface complete all as specified and directed by Engineer-in-Charge.
M & L for formwork to sides of pillars, posts, struts, piers, columns and stanchions etc.for fair finished surface complete all as specified and directed by Engineer-in-Charge.
M & L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete raillings , opening in concrete walls, floors and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, hozontal or sloping and similar work exc 5cm but n exc 10cm etc.for fair finished surface complete all as specified and directed by Engineer-in-Charge.
All as per above item No-13 but n exc 5cm wide for rough finished complete all as specified and directed by Engineer-in-Charge.
M&L for mild steel TMT bars 10mm dia and over cut to length,bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge.
All As per above item No15 but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed by Engineer-in-Charge.
M & L for brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
M&L for 40 mm thick DPC on horizontal or vertical surfces in PCC 1:2:4 type B0 using 12.5mm graded stone agg incl all necessary form work and mixing of WPC (WPC shall be measured and shall paid seperately) complete all as specified and directed by Engineer-in-Charge.
M & L for hardcore of gauge n exc.63 mm(using broken stone or boulders) deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge.
M & L for 100 mm thick cement concrete type D-2, 1:4:8 (40 mm graded stone aggregate) as in sub base complete all as specified and directed by Engineer-in-Charge.
M & L for non skid ceramic coloured tiles of 7 to 8 mm thick (Square/rectangular) area of each tile exc 0.11 sqm but nexc 0.18 sqm, in floors etc.set and jointed in neat cement slurry and pointed in white/coloured cement to match with the shade of tiles and including cement screeding 15mm thick in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
M & L for Glazed ceramic coloured tiles 600x 300 x 9 to 10mm thick in dado, set and jointed in neat cement slurry and pointed in colour cement to match including rendering 10mm thick in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge.
M & L for 75 mm thick cement concrete type C-1, 1:3:6 (using 20mm graded stone aggregate) as in plinth protection complete all as specified and directed by Engineer-in-Charge.
M& L for rendering 15 mm thick in CM 1 : 6 on other than fair faces of brick work or concrete surfaces etc finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15 mm thick in CM 1:4 on fair faces of concrete or brick surfaces finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 5 mm thick in CM 1 : 3 on brick or concrete surfaces (in ceiling) etc finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Supply only liquid integral water proofing admixtures complete all as specified and directed by Engineer-in-Charge.
S & F anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc.complete all as specified and directed by Engineer-in-Charge.
S & F Solid PVC Double door frame of size 50mm x 95mm made out of 5mm Plain colour PVC sheet reinforced with M.S. tube, supplying & Fixing in opening as per specification & drawing complete all as specified and directed by Engineer-in-Charge.
S & F Factory Made Solid PVC Moulded Door Shutters 28 to 30 mm thick (stile:), with 2,4 or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front Face & 2mm Plan colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed by Engineer-in-Charge.
S & F 150 mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed by Engineer-in-Charge.
S & F 150 mm long extruded aluminum alloy handles fabricated type and anodised complete all as specified and directed by Engineer-in-Charge.
S & F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm complete all as specified and directed by Engineer-in-Charge.
S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square n exc 0.50 sqm in each pane complete all as specified and directed by Engineer-in-Charge.
S & F cast iron soil, waste and vent pipes( sand cast pipes) 100 mm bore in any length with or without ears, with cement joint laid in trenches or in floors complete all as specified and directed by Engineer-in-Charge.
S & F bends 100 mm size dimnishing pieces or tapers (larger bore measured) complete all as specified and directed by Engineer-in-Charge.
S & F branch pieces 100 mm size, single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed by Engineer-in-Charge.
S & F 75mm dia cast iron soil waste and vent pipe (ISI marked) sand cast, in any length with or without ears with cement joint complete fixed in floors or walls and in any other places, complete all as specified and directed by Engineer-in-Charge.
S & F cast iron floor trap including jointing to waste pipe in run lead, dia of outlet 75mm, complete all as specified and directed by Engineer-in-Charge.
M & L for 15mm bore galvanised steel water tubing medium grade with all fittings (ISI Marked) and fixed complete to walls and or laid under floors etc complete all as specified and directed by Engineer-in-Charge.
All as per item No 40 above but 20mm bore pipe complete all as specified and directed by Engineer-in-Charge..
S & F vitreous china white glazed european type WC with white ISI marked plastic seat cover and flush pipe complete all as specified and directed by Engineer-in-Charge.
S&F PVC Low level flushing cistern 10 ltr capacity incl internal fittings,sypons,handle,bend etc complete(Make commander/cera/parryware) incl S&F 2 Nos CI brackets, waste pipe and coupling complete all as specified and directed by Engineer-in-Charge.
S & F pvc connection 15mm dia of standard pattern 600 mm long, with two Nos brass check nuts (adopts) and washers etc complete all as specified and directed by Engineer-in-Charge.
S & F 125mm dia MS chromium plated grating fixed in cement mortar (1:3) complete all as specified and directed by Engineer-in-Charge.
S & F towel rail 600mm long brass chromium plated of 20mm dia (external) and 1mm thickness with gutties embeded in cement mortar 1:3 with MS screws etc complete all as specified and directed by Engineer-in-Charge.
S & F Two way bib tap of 15 mm dia complete all as specified and directed by Engineer-in-Charge.
S & F brass CP angle valve 15 mm dia including connecting to PVC/CP connection complete all as specified and directed by Engineer-in-Charge.
S & F concealed brass chromium plated stop valve fancy type suitable for 15mm bore of pipe with long shank and cup (Make- Marc/Jaquar/kohlar). complete all as specified and directed by Engineer-in-Charge.
S&F rotational moulded polyethylene water storage tank double layer (cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR Part -I, 1000 Ltr capacity complete all as specified and directed by Engineer-in-Charge.
S&F 20 mm ball valve PTMT high pressure with polythene float and flynut complete screwed for iron pipe. complete all as specified and directed by Engineer-in-Charge.
S&F 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.
M&L two coats of synthetic enamel paint over a coat of pink primer on new wood or wood based surfaces not otherwise described over 10 cm width or girth incl preparation complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new or untreated steel surface and applying two coat of synthetic enamel paint over a coat of red oxide primer on the surface of any description over 10 cm in width or girth not otherwise descripbed
M & L for applying white wash three coats on newly plastered surfaces of ceiling including preparation of new surfaces for matching with repaired surfaces complete all as specified and directed by Engineer-in-Charge.
M & L for applying three coat of cement base paint on newly plastered surfaces of walls including preparation of new surfaces complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engineer-in-Charge..
M & L for removing excavated material exc. 250m but not exceeding 500m and depositing where complete all as specified and directed by Engineer-in-Charge.
S&F aluminium window partly glazed/ gauzed including provision for fixing the exhaust fan complete all as specified and directed by Engineer-in-Charge.
S & F wash hand basin vitreous china white glazed flat back, size 550 x 400 mm, including brackets and cutting for and pinning in ends of brackets excluding waste pipe and coupling etc complete all as specified and directed by Engineer-in-Charge.
S & F Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to lugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed by Engineer-in-Charge.
M & L for brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius in half brick thick walls built in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
M & L for water proof treatment to RCC roof slab incorporating CONPLAST WL (water proofing compound) in the proportion as directed by the manufacturer and apply on damp pcc surface first coat of brush bond RFX and again apply second coat of brush RFX after drying of first coat (average 1 mm thickness) and on completion 25 mm thick pcc 1:2:4 mix (4 parts of 10 mm normal coarse aggregates, 2 parts of fine aggregate and one part of cement) cement concrete screed and finsih the top surface. Complete roof shall be tested by ponding of water for 24 hrs. Note :- Brush bond RFX liquid powder and CONPLAST WL shall be of FOSROC or equivalent in pidilite complete all as specified and directed by Engineer-in-Charge.
M&L for 25mm thick Sand filling under floors or in foundation including watering and consolidation complete all as specified and directed by Engineer-in-Charge.
M & L for machine pressed precast concrete interlocking paver block with grey cement and pigment of any shape and size confirming to IS 15658-2006 of 60 mm thickness M-40 Grade complete all as specified and directed by Engineer-in-Charge.
M & L for cement concrete type B0 1:2:4 (using 12.5 mm graded aggregates) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed complete all as specified and directed by Engineer-in-Charge.
M & L for cement concrete type C2 (1:4:8) using 40 mm graded as in foundation filling and mass concrete complete all as specified and directed by Engr in charge
M&L for Cement Concrete Type B1 1:2:4 (20mm graded aggregate) as in copings, kneelers, apex stones, bed plates, including weathering, slightly rounded for chamfered angles and throating, complete all as specified and directed by Engineer-in-Charge.
M & L for applying three coats of white wash on newly plastered surfaces of walls including preparation of surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete 1 : 4 : 8 type D2 using 40mm graded stone aggregates incl packing under and haunching against the sides for 150mm internal dia DWCPE pipes after they are laid and tested complete all as specified (thickness of concrete bed 100mm) complete all as specified and directed by Engineer-in-Charge..
Supply and laying, jointing 150mm internal dia of DWCPE pipe in lieu of SGSW incl testing and laid in trenches to a level on concrete bed complete all as specified and directed by Engineer-in-Charge.
M&L for providing pre cast RCC !:2:4 type B-1 using 20 mm graded stone aggregate as in cover slab and man hole covers etc complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete 1:2:4 type B-2 using 40mm graded stone aggregate as in surface channels complete all as specified and directed by Engineer-in-Charge.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, mounds, mitred/stopped end etc complete all as specified and directed by Engineer-in-Charge..
Cast of Septic tanks, 25 user exc, in ordinary soil, foundation In PCC 1:2:4, brick work in CM 1:4, RCC Slab covers including RCC precast manhole cover having 6mm plate embedded all around/fibre reinforced cover with angle iron frame Vent shaft and sludge chambers etc., complete all as shown in drg fro 25 user septic tank.
S & F for precast fibre reinforced cement concrete Manhole cover (Ist quality) including grove and hook arrangement for lifting and placing in position and sides covered by MS sheet medium duty of overall Size 1000mmx500mmx80mm complete all as specified and directed by Engineer-in-Charge.
S & F for precast plastic fibre reinforced cement concrete Manhole covers with frame medium duty of overall size 450mmx450mmx50mm factory made (make-polycrete) all as specified and directed by Engineer-in-Charge.
M & L for Brick work sub class ‘B’ bricks state or curved on plan built in cement mortar 1:4 using old size bricks.complete all as specified directed by Engr-in-Charge.
M & L for Cement concrete 1:3:6 type C-2(40mm aggregate ) as in foundation manholes.complete all as specified directed by Engr-in-Charge.
M&L for PCC ,type B-1 1:2::4(20 mm Graded aggregate) in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directing complete all as specified and directed by Engineer-in-Charge.
M&L for Providing, precast cement concrete type B-1 1:2:4 (20 mm Graded Aggregate )in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces etc.(of any section indicated), with plain fair faces, including chamfers weatherings, throating etc. and setting in mortar complete with joints to match complete all as specified and directed by Engineer-in-Charge.
M&L for Cement concrete 1:2:4 type B-1 (20 mm graded aggrigate ) as in surface channels and drains complete all as specified and directed by Engineer-in-Charge.
S & F for precast fibre reinforced cement concrete DRAIN cover (Ist quality) including grove and hook arrangement for lifting and placing in position and sides covered by MS sheet medium duty of overall Size 900mmx900mmx80mm complete all as specified and directed by Engineer-in-Charge.
M & L Machine pressed precast concrete PU coated colour interlocking paver block any shape and size, with grey cement and pigment confirming to IS 5658-2006 of 80 mm thickness M-35 Grade complete all as specified and directed by Engineer-in-Charge.
M&L for Reinforced Concrete pipes 600 mm class NP2,Laid and jointed Complete with collars laid in trenches and jointed complete all as specified and directed by Engineer-in-Charge.
S & F MS framed work such as grills, gratings etc with ends of bars shouldered and or riveted, framed guard bars, barred iron doors, ladders, frame work of water trough, railings,cooler stand and similar work to conforming to Fe -290-0 ornamental design, complete all as specified and directed by Engineer-in-Charge.
All as per item No 1 but exc 1.5 mtr and n exc 3.00 mtr depth complete all as specified and as directed by Engineer in chrge.
M&L for Cement conc 1:4:8 type D-2 bed to 300 mm drain pipes incl packing under and haunching against the sides of pipe after they are late and tested thickness of PCC bed 200mm complete all as specified and directed by Engineer-in-Charge..
M&L for Cement conc 1:4:8 type D-2 bed to 200 mm drain pipes incl packing under and haunching against the sides of pipe after they are late and thicknes of PCC bed 150mm complete all as specified and directed by Engineer-in-Charge..
M&L for L Salt glazed stoneware drain pipes 200 mm laid in trenches and jointed complete all as specified and directed by Engineer-in-Charge.
M&L for Reinforced Concrete pipes 300mm class NP2,Laid and jointed Complete with collars laid in trenches and jointed complete all as specified and directed by Engineer-in-Charge.
M&L for Cutting of exising 200 mm dia manholes for connecting new drains making good to pipe and rendering cutting out exising benching for and forming benching for and forming branch channel (1/2round or 3/4 section ) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching required complete all as specified directed by Engr-in-Charge.
M&L for Cutting of exising 150mm dia manholes for connecting new drains making good to pipe and rendering cutting out exising benching for and forming benching for and forming branch channel (1/2round or 3/4 section ) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching required complete all as specified directed by Engr-in-Charge.
M&L for Rendering 10mm thick on fair face on brick work or conc surfaces finished even and smooth without using extra cement in CM 1:4.complete all as specified and directed by Engineer-in-Charge.
Cleaning /Desludging of manhole /septik tank by excavating sludge depth 1.5 to 3 mtr depth and size not exceeding 4 cum each manual labour /machenical scrappers etc. and disposal of the sludge including dumping of waste material out side the MOD land complete all as specified and directed by Engineer-in-Charge.
Cleaning /Desludging of manhole by excavating sludge depth 1.5 to 3 mtr depth and size not exceeding 2 cum each manual labour /machenical scrappers etc. and disposal of the sludge including dumping of waste material out side the MOD land complete all as specified and directed by Engineer-in-Charge.
M&L for sub main wiring with two single core FRLS stranded copper conductor cable 1100 volts grade of size 4.0 sqmm and one single core FRLS stranded copper conductor cable 4 sqmm for earth wire in and including medium grade PVC concealed conduit with all fittings complete all as specified and directed by Engineer-in-Charge.
M&L for cutting steel tubing to required length for insertion of new Tee Branches, reducer in any position of 15mm dia pipe line complete all as specified and directed by Engineer-in-Charge.
S&F sheet metal enclosure single pole and Neutral with a two pin earth plug and socket complete with a MCB SP 10 Amp 220 volts, 50 Hz, 10KA breaking capacity, including fixing completly in wall with sutable sand and cement, complete all as specified and directed by Engineer-in-Charge.
S&F tubes, 'medium grade', galvanised, with all fitting; for fixing concealed/surface in wall complete of 15mm dia with complete fitting and fixture complte all as specified and directed by Engr-in-charge.
S&F of Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of cap 15mm dia complete all as specified and directed by Engineer-in-Charge.
S&F Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed of cap 15mm dia complete all as specified and directed by Engineer-in-Charge.
S&F PVC connection 15 mm size for cold water with PTMT nuts of length 450 mm complete all as specified and directed by Engineer-in-Charge.
S&F CP connection 15 mm size with for hot water with PTMT nuts of length 450 mm.complete all as specified and directed by Engineer-in-Charge.
S & F water heater storage type Geyser vertical type with suitable size of fastner and including provision and connecting up of SS braidedpipe with adopter for inlet and outlet wwater connection having edjustable knob for temperature control and inner tank should be glass line coated, capacity 25 Ltrs, having heating element 1.5 KW and 5 star rating, suitable for ,230 volt, 50 Hz electric supply complete all as specified and directed by Engineer-in-Charge.
S&F stop valves 15 mm bore CP With crutch or butterfly handle, screwed both ends for iron pipe or unions, complete all as specified and directed by Engineer-in-Charge.
M&L MCB SP 20 Amp "C" curve ,10 kA complete all as specified and directed by Engineer-in-Charge..
M&L point wiring with PVC insulated FRLS 1100 Volts unsheathed cable 1.5 Sqmm multistranded copper conductor and drawing concealed in wall & including rigid PVC conduit FRLS, medium grade ,ISI marked ,terminal box of 1.6 mm thick and 3 mm thick hylam sheet cover for terminal boxes also including porvision of earth wire PVC insulated FRLS 1100 Volts unsheathed 1.5 sqmm stranded copper conductor single core cable connected to common earth dolly the following :
One light/fan point controlled by one by one way switch ( switch to be measured and paid separtely)
All as above item No 110.01 but Same board.
M&L switch piano flush type 5 Amp SP one way complete all as specified and directed by Engineer-in-Charge
M&L socket outlet 5 pin 5 Amp flush type complete all as specified and directed by Engineer-in-Charge
M&L ceiling rose 3 phase PVC polycorbonate,isolated body complete all as specified and directed by Engineer-in-Charge
Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 22 Watts with lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level > 100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
Supply and fix LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 900 lm system lumen output with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, short circuit and over circuit protection, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed
Supply and fix MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as specified and directed by Engineer-in-Charge
Supply and fix MCB SPN 40 Amps 240 volts 10 KA 50 HZ C curve complete all as specified and directed by Engineer-in-Charge
Supply and fix MCB SP 6 to 32 Amps 240 volts 10 KA 50 HZ C curve complete all as specified and directed by Engineer-in-Charge
Supply and lay cable in replacement XLPE insulated screened PVC bedded, galvanized steel strip and wire armoured , electric power cables (heany duty) 1100 volts grade with stranded alumimium conductor of size 10 Sqmm 2 core complete all as specified and directed by Engineer-in-Charge
Supply and Fix 45 W High efficient LED Street light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie is 100lm/W with a life class of 50,000 burning hours at L70.The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including providing of 40mm dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole fixed complete all as specified and directed by Engineer-in-Charge
Supply and fix metal body exhaust fan 300 mm sweep 230 volt single phase including making provision of suitable size in wall for fixing the exhaust fan ,all connected items for fixing on wall and making connection with flexible wire, complete all as specified and directed by engr-in-charge.
M & L for earthing complete with galvanized steel earth plate 600x600x6mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of the plate not less than 1.50 mtr below normal ground level, connected to earth lead GI 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron and connection to main switch board of panel, including watering pipe GI 20 mm bore light grade 15mm bore for earthing lead, wire mess, funnel, salt, charcoal dust, excavation and refilling pit with PCC 1:2:4 type B1(using 20mm dia stone aggregate) reinforced with 6mm dia round bar @ 75mm cement concrete both always with MS handle 12mm dai and frame all as shown in electric plate No 3 in page 497 of SSR Part I (2009) including testing ion completion all as directed
Supply and fix 10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, CRI>80, Color Temperature-6500K, Surge protection of 4.0 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
Excavation in trenches n.exc 0.45 m wide and n.exc 0.60 m depth for laying of LT cables etc. and getting out in soft/loose soil complete all as specified
Returning, filling in, including spreading levelling, watering and well ramming in layers not exc, 25cm depth in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Removing excavateed material to a distance not. Exc 50 m and deposting where directed at a level not. Exc 0.6 m above the starting point complete all as specified and directed by Engineer-in-Charge
Supply and spreading clean dry sand in trenches for cushioning/cable protection complete all as specified and directed by Engineer-in-Charge
Supply and laying sub clas 'B' Bricks of old size ( 23 x 11 x 7 cm) laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer -in-Charge
GIAN ENGINEERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .