Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC C O RANJIT KUMAR NARZARY VILL ANTHAIBARI PO PS BENGTOL DIST CHIRANG PIN 783394 | CHIRANG | ASSAM | 783394 | ₹1.2 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.3 Cr+₹6.9 L (5.56%)Rejected-AOC | ₹1.3 Cr+₹6.9 L (5.56%) | L2 | Rejected-AOC L2 |
| 3 | L3₹1.4 Cr+₹13.9 L (11.1%)Rejected-AOC S O SRI KAMALA KANTA KHAKLARY VILL RUNIKHATA P O P S RUNIKHATA DIST CHIRANG BTR ASSAM | ₹1.4 Cr+₹13.9 L (11.1%) | L3 | Rejected-AOC L3 |
| 4 | Rejected-Technical PAGLASTHAN BONGAIGAON ASSAM | DHUBRI | ASSAM | 783371 | - | - | Rejected-Technical reject |
Tender Value
₹1.4 Cr
EMD Value
₹2.8 L
Closing Date
27 Dec 2021, 1:30 pmClosed
The Addl. Chief Engineer cum Director, PWD,BTC
O/o the Addl. Chief Engineer cum Director, PWD,BTC,Kokrajhar
Construction of boundary wall at Dangsrang Club and Library at South Kajalgaon, Dist. Chirang including drainage system, sanitation and water facility therein. (TN_30_8_R_1)
2021_BTC_23767_1
No. ACE- 05/CHN/IFB/2018-19/335
Open Tender
Civil Works - Building
Item Rate
365 days
chirang
Please refer Tender documents.
6 documents required · 6 mandatory
₹4,200
The Principal Secretary, BTC, Kokrajhar
₹2.8 L
Yes
12 Jan 2022
20 Dec 2021
27 Dec 2021
20 Dec 2021
27 Dec 2021
20 Dec 2021
20 Dec 2021 - 27 Dec 2021
Amount
(A) Brick Boundary Wall: Earth work in excavation for foundation trenches of walls, retaining walls, footing of column, steps and septic tank etc. including refiling (return filling) the quantity as necessary after completion of work, breaking clods in return filling dressing, watering and ramming etc. and removal of surplus earth with all lead & lift as directed and specified in following classification of soils including bailing out water where necessary as directed and spedified. (A) Up to a depth of 2.0 m below the existing G.L (a) In Ordinary Soil.
Providing brick soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparting the subgrade as directed including all labour and materials and if necessary dewatering complete. (a) Brick on flat soiling.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing, steps, walls, brick works etc. as directed and specified including dewatering if necessary and curing complete (Shuttering where necessary shall be measured and paid separately.) (a) In prop 1:3:6 (1 cement :3 coarse sand: 6 coarse aggregate by volume. (using mixture machine).
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work/R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks, supprots, chairs, spacers etc. complete. (upto 1st floor level) b) Other ISI approved TMT reinforced bar (SAI/BISCON/THERMAX) (For Assam Type Bldg., drain works,,retaining wall & boundary wall etc.
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc hight of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work. 3.2.1.1. Colums, pillars, posts & strut of square/rectangular/polygonal in plan or any shape like Tee/L etc.having plane vertical face.
Providing and laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding coast of from work and reinforcement for reinforce cement concrete work. (from work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (A) In Sub-Structure up to plinth level Foundation, footing, columns with base, tie & plinth beam, pile cap, base slab, retaining walls, walls of the septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level. N) With out admixture, plasticiser b) M-20 grade concrete ro prop.1:1.5:3
Providing and laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding coast of from work and reinforcement for reinforce cement concrete work. (from work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (A) In Super-Structure from plinth level up to 1st floor level. (ii) Colums, pillars, posts, struts, suspended floor, roof landing, shelf & support balcony, lintel, sill band, beam, girder, bressumer, cantilever, stair case (except spiral stair case and landing) including preparing the top surface & finishing of nosing. N) With out admixture, plasticiser b) M-20 grade concrete ro prop.1:1.5:3
Brick work in cement morter with 1st class brick including racking out joints and dewarting if necessary and curing complete as directed. (I) In Sub-Structure upto plinth level including dewatering if necessary (b) In proportion 1:4
112mm thick 1st class brick nogged wall in cement morter including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) A) 112 mm thick brick wall. b) In cement mortar in proporation 1:4 (1 cement: 4 sand)
15mm thick cement plaster in single coat on rough side of single half brick wall for interior plastering upto 1st floor level including arrises, internal round angle not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. A) On rough side (b) In cement mortar 1:4 (1 cement: 4 sand)
(a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after thoroughly brooming the surface free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
(b) Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface (two coats) to give an even shade after thouroughly brooming the surfaces to remove all dirt and remains of loose powered materials.
Supplying fitting and fixing double leaf heavy duty iron gate frame made from 50mm x 6mm M.S flat iron with another horizontal flat at the middle, 20mm dia M.S bars at 200mm apart from bottom flat to top and 20mm dia M.S bars 200mm apart from bottom flat to middle flat including drilling welding etc. complete.
(B) Construction of External & Internal Drain: RCC Drain Earth work in excavation for foundation trenches of walls, retaining walls, footing of column, steps and septic tank etc. including refiling (return filling) the quantity as necessary after completion of work, breaking clods in return filling dressing, watering and ramming etc. and removal of surplus earth with all lead & lift as directed and specified in following classification of soils including bailing out water where necessary as directed and spedified. (A) Up to a depth of 2.0 m below the existing G.L (a) In Ordinary Soil.
Providing brick soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparting the subgrade as directed including all labour and materials and if necessary dewatering complete. (a) Brick on flat soiling.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing, steps, walls, brick works etc. as directed and specified including dewatering if necessary and curing complete (Shuttering where necessary shall be measured and paid separately.) (a) In prop 1:3:6 (1 cement :3 coarse sand: 6 coarse aggregate by volume. (using mixture machine).
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work/R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks, supprots, chairs, spacers etc. complete. (upto 1st floor level) b) Other ISI approved TMT reinforced bar (SAI/BISCON/THERMAX)
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work/R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks, supprots, chairs, spacers etc. complete. (upto 1st floor level) b) Other ISI approved TMT reinforced bar (SAI/BISCON/THERMAX) 3.1.2 Sides and Soffits of Beams, beam haunchings, cantilever girders and bressumers.
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work/R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks, supprots, chairs, spacers etc. complete. (upto 1st floor level) b) Other ISI approved TMT reinforced bar (SAI/BISCON/THERMAX) 3.1.3 Flat Surfaces such as soffits of suspended floors, roofs, landings and the like.
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work/R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks, supprots, chairs, spacers etc. complete. (upto 1st floor level) b) Other ISI approved TMT reinforced bar (SAI/BISCON/THERMAX) 3.1.5 Vertical surface such as walls (any thickness), Lift shafts, partitions and the like including attached pilasters, butresses, plinth and string courses and the like.
Providing and laying plain/reinforced cement croncrete works cement with coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using mixture machine (A) In sub - structure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. (N) with out admixture, plasticiser (b) M20 grade concrete ro prop. 1:1.5:3
Peripherial Drain Earth work in excavation for foundation trenches of walls, retaining walls, footing of column, steps and septic tank etc. including refiling (return filling) the quantity as necessary after completion of work, breaking clods in return filling dressing, watering and ramming etc. and removal of surplus earth with all lead & lift as directed and specified in following classification of soils including bailing out water where necessary as directed and spedified. (A) Up to a depth of 2.0 m below the existing G.L (a) In Ordinary Soil.
Providing brick soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparting the subgrade as directed including all labour and materials and if necessary dewatering complete. (a) Brick on flat soiling.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing, steps, walls, brick works etc. as directed and specified including dewatering if necessary and curing complete (Shuttering where necessary shall be measured and paid separately.) (a) In prop 1:3:6 (1 cement :3 coarse sand: 6 coarse aggregate by volume. (using mixture machine).
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work/R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks, supprots, chairs, spacers etc. complete. (upto 1st floor level) b) Other ISI approved TMT reinforced bar (SAI/BISCON/THERMAX)
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.1 Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face.
Providing and laying plain/reinforced cement croncrete works cement with coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using mixture machine (A) In sub - structure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. (N) with out admixture, plasticiser (b) M20 grade concrete ro prop. 1:1.5:3
Brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed . (I) In sub-structure up to plinth level including dewatering if necessary (b) In proportion 1:4
15 mm thick Cement plaster in single coat on rough side of single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. (A) On rough side (b) In Cement mortar 1:4 (1 cement : 4 sand )
Supplying fitting and fixing M.S angles MS flat MS bolts and nut including painting with red lead paint one coat complete as directed.. b) MS flats.
(C) Construction of Toilet: Earth work in excavation for foundation trenches of walls, retaining walls, footing of column, steps and septic tank etc. including refiling (return filling) the quantity as necessary after completion of work, breaking clods in return filling dressing, watering and ramming etc. and removal of surplus earth with all lead & lift as directed and specified in following classification of soils including bailing out water where necessary as directed and spedified. (A) Up to a depth of 2.0 m below the existing G.L (a) In Ordinary Soil.
Providing brick soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparting the subgrade as directed including all labour and materials and if necessary dewatering complete. (a) Brick on flat soiling.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing, steps, walls, brick works etc. as directed and specified including dewatering if necessary and curing complete (Shuttering where necessary shall be measured and paid separately.) (a) In prop 1:3:6 (1 cement :3 coarse sand: 6 coarse aggregate by volume. (using mixture machine).
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work/R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks, supprots, chairs, spacers etc. complete. (upto 1st floor level) a) From Primary Producer: TATA/SAIl/Esser Steel/Jindal Steel/Shyam Steel/RINL (i) TMT Corrosion resistant steel (CRS) reinforcement bar.
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: 3.1.1.1 Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. (b) Using 25mm thick plank
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: 3.1.1.2 Sides of tie beams, grade beams etc. at or below ground level. (b) Using 25mm thick plank
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: 3.2.1.1 Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face.
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (A) In substructure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. N) Without using admixture, plasticiser b) M20 grade concrete or Prop. 1:1.5:3
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (i) In Sub-structure upto plinth level including dewatering if necessary (b) In proportion 1:4.
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (c) With silt (predominantly non plastic) by truck carriage including loading and unloading.
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using mixture machine. (B) In super structure from plinth level up to 1st floor level. ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. N) Without using admixture, plasticiser b) M20 grade concrete or Prop. 1:1.5:3
3.1.1.4 Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M. (ii) using 25mm thick plank
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
112mm thick 1st class brick nogged wall in cement morter including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall (b) In cement mortar in proporation 1:4 (1 cement: 4 sand)
Providing fitting, hoisting and fixing of roof trusses including purlins fabricated out of M.S. black tube conforming to relevent I.S. code, as per approved and drawings including providing M.S. cleats, platesbolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paintscomplete including fitting necessary clear etc.for fixing joists as per design and drawings as directed. b) Using other ISI marked approved circular hollow section
Providing corrugated galvenised Iron sheet roofing of TATA SHAKTEE/SAIL including fitting and fixing necessary galvenised J or L hooks, bolts and nuts 8mm dia with bitumen washer 25mm dia x 3mm thick and 1.6mm thick and purlin etc.to be measured and paid separately). (c) 0.55mm thick
15mm thick cement plaster in single coat on rough side of single half brick wall for interior plastering upto 1st floor level including arrises, internal round angle not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. A) On rough side (b) In cement mortar 1:4 (1 cement : 4 sand)
Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 corse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (a) 15mm thick
Providing fitting and fixing 40mm x 48mm wood reinforced PVC chowkhats foxed to the colums /stiffencrs/walls with necessary holdfast/sleeves etc. as specified and directed at all levels.
Providing fitting and fixing 24mm x 29mm thick polymer reinforced moulded PVC door shutters fixed to the chowkhath with necessary hinges, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid separately) b) 29mm thick
Plain cement concrete floor base in prop 1:3:6 laid in alternate bays as specified with agg. Of size 13mm to 32mm including dewatering if necessary and curing etc. complete. Ii) 50mm thick in prop 1:3:6
Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Cement plastering to be measured and paid separately) (coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) a) Executive range (Somany Varmora/Orient make) ii) Of size 800mm x 800mm
Providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately) (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the department). (Walls means both interior and exterior walls) i) Of size 300mm x 450mm and above
Providing surface preparation for walls, ceilling etc, using average 1.50mm thick plaster of paries of pares including clearing rubbing with sand paper filling gaps, depression etc. where necessary with chalk powder and plaster of pairs paste making the surface even and smooth complete at all levesl as specified and directed.
(a) Clour washing with lime on wall surface (two coats) over and including a priming coat of white washing to give an even shade after thouroughly brooming the surface to remove all dirt, dust mortar drops and other foreign matter.
Providing drain with brick work in cement mortar in prop 1:5 with half brick thick side walls and 100mm thick CC (1:3:6) base over one brick flat soiling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shettering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. (ii) 300 wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
Providing plinth protection with bricks flat laid in cement mortar 1:4 and finished with 15mm thick cement plaster in prop 1:2 with a floating coat of neat cement finish.
Sanitary Installation and water Supply Works: Providing fitting and fixing vitreous water closet squatting pan (indian type W.C Orrisa pattern) with all fittings and fixtures complete including cutting and making good to the walls and floors whereever required. (Flushing Cistern to be paid separately) 1.1.1 Indian type W.C Orrisa pattern of size 580 x 440mm a) White (ii) Hindware make
Supplying, fiting and fixing PVC flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately) i) Parryware make a) White (viii) Tiger (Cat No.C8260)
Providing fitting and fixing vitreous china flat back type lipped front urinal basin of with standard flush pipe and CP brass spreader and brass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. (A) Parryware make a) White (iv) Flat Back (Cat. No.C0501/72)
Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) 1.13.2 Basin (without pedestal) (A) Parryware Make (a) White (ii) Tapti Basin 500 x 360 (Cat. No.C0424/410)
Providing fitting and fixing Mirror with plastic frame of size 500x400mm complete as directed and specified.
Providing fitting and fixing recessed soap tray/soap dish complete as directed and specified. (a) Parryware make (iii) Corner Soap tray (Cat No.C9949)
Providing fitting and fixing PVC cowel of ISI make complete as directed and specified (ii) 110mm dia PVC cowel of ISI make
Supplying fitting and fixing approved uPVC Pipes of different sizes, with all necessary 'R' brand or similar approved P.V.C. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. (A) Exposed or in trenches SUPREME/ PRINCE/ SFMC BRAND or other equvalent approved brand (High presure pipe Sch-40) Exposed or in trenches d) 25 mm
Supplying fitting and fixing approved uPVC Pipes of different sizes, with all necessary 'R' brand or similar approved P.V.C. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. (A) Exposed or in trenches SUPREME/ PRINCE/ SFMC BRAND or other equvalent approved brand (High presure pipe Sch-40) Exposed or in trenches f) 20 mm
Supplying fitting and fixing approved uPVC Pipes of different sizes, with all necessary 'R' brand or similar approved P.V.C. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. (A) Exposed or in trenches SUPREME/ PRINCE/ SFMC BRAND or other equvalent approved brand (High presure pipe Sch-40) Exposed or in trenches f) 15 mm
Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) (I) Essco make (Delux/Sumthing spl./Tropical) (a) Bib cock short
Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P. pipes will be measured and paid separately) I) Brass stop cock (heavy) of Sant make (ii) 20mm dia
Supplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed. (i) Sona make (b) Heavy type
Supplying fitting and fixing Chrome Plated (C.P.) flush cock of approved brand as directed and specified.(G.I. & C.P pipes will be measured and paid separately) (I) Agmeco brand a) Flush cock Economy Cat No.00506
Supplying fitting and fixing Pipes with all necessary fittings in exposed or in trenches including trenching and refilling the same etc complete as directed. B) uPVC pipe with uPVC fittings ( Using uPVC high pressure pipe) (Using SUPREME/ PRINCE/ SFMC/ FUSION brand pipe) vii) 63mm diameter
Supplying fitting and fixing Pipes with all necessary fittings in exposed or in trenches including trenching and refilling the same etc complete as directed. B) uPVC pipe with uPVC fittings ( Using uPVC high pressure pipe) (Using SUPREME/ PRINCE/ SFMC/ FUSION brand pipe) x) 110mm diameter
Septic Tank, 2 Nos: Earth work in excavation for foundation trenches of walls, retaining walls, footing of column, steps and septic tank etc. including refiling (return filling) the quantity as necessary after completion of work, breaking clods in return filling dressing, watering and ramming etc. and removal of surplus earth with all lead & lift as directed and specified in following classification of soils including bailing out water where necessary as directed and spedified. (A) Up to a depth of 2.0 m below the existing G.L (a) In Ordinary Soil.
Providing brick soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparting the subgrade as directed including all labour and materials and if necessary dewatering complete. (a) Brick on flat soiling.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing, steps, walls, brick works etc. as directed and specified including dewatering if necessary and curing complete (Shuttering works where necessary shall be measured and paid separately.) (a) In prop 1:3:6 (1 cement :3 coarse sand : 6 coarse aggregate by volume. (using mixture machine).
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work/R.B. walling including straightening,cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks,supprots,chairs,spacers etc complete. (upto 1st floor level) c) ISI approved Mild steel reinforcement bar (M.S.Bar)
3.1.1.5 Flat surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. Upto 200mm in thickness (ii) Using 25mm thick plank.
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-Structure upto plinth level including dewatering if necessary (b) In proportion 1:4
Providing and laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding coast of from work and reinforcement for reinforce cement concrete work. (from work and reinforcement will be measured and paid separately) (i) Using Mixer Machine (a) In Sub-Structure up to plinth level Foundation, footing, colums with base, tie & plinth beam, pile cap, base slab,retaining walls, walls of the septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level. N) Without using admixture plasticiser a) M-15 grade concrete or prop.1:2:4
15mm thick cement plaster in single coat on rough side of single half brick wall for interior plastering upto 1st floor level including arrises, internal round angle not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. A) On rough side (b) In cement mortar 1:4 (1 cement: 4 sand)
(D) Construction of (OHT) Over Head Storage PVC Tank: Earth work in excavation for foundation trenches of walls, retaining walls, footing of column, steps and septic tank etc. including refiling (return filling) the quantity as necessary after completion of work, breaking clods in return filling dressing, watering and ramming etc. and removal of surplus earth with all lead & lift as directed and specified in following classification of soils including bailing out water where necessary as directed and spedified. (A) Up to a depth of 2.0 m below the existing G.L (a) In Ordinary Soil.
Providing brick soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparting the subgrade as directed including all labour and materials and if necessary dewatering complete. (a) Brick on flat soiling.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing, steps, walls, brick works etc. as directed and specified including dewatering if necessary and curing complete (Shuttering works where necessary shall be measured and paid separately.) (a) In prop 1:3:6 (1 cement :3 coarse sand : 6 coarse aggregate by volume. (using mixture machine).
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work/R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks,supprots,chairs,spacers etc complete. (upto 1st floor level) a) From Primary Producer: TATA/SAIL/Esser Steel/Jindal (i) TMT Corrosion resistant steel (CRS) reinforcement bar.
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc. hight of proping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in: 3.1.1.1 Foundation, footing, base of colums, pile cap, raft and mass concrete works etc. (b) Using 25mm thick plank
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc. hight of proping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.1. Columns, Pillars, post & struct of square/rectangular/polygonal in plan or any shape like Tee/L etc. having plane vertical face..
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc. hight of proping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.2. Sides and soffits of beams,beam haunchings,cantilever, girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc. hight of proping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.3. Flat surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas,balconies and the like. (a) Floors etc. upto 200mm in thickness.
Providing and laying plain/reinforced cement concrete works cement with coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding coast of from work and reinforcement for reinforce cement concrete work. (from work and reinforcement will be measured and paid separately) (i) Using mixture machine (a) In Sub-Structure up to plinth level Foundation, footing, colums with base, tie & plinth beam, pile cap, base slab,retaining walls, walls of the septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level. (N) With out admixture, plasticiser (b) M-20 grade concrete ro prop.1:1.5:3
Brick work in cement morter with 1st class brick including racking out joints and dewarting if necessary and curing complete as directed. (I) In Sub-Structure upto plinth level including dewatering if necessary (b) In proportion 1:4
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming, etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (C) With site (predominantly non plastic) by truck carriage including loading and unloading.
Providing and laying plain/reinforced cement concrete works cement with coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding coast of from work and reinforcement for reinforce cement concrete work. (from work and reinforcement will be measured and paid separately) (i) Using mixture machine (b) In Super Structure from plinth level up to floor level. (ii) Colums, pillars, posts, struts, suspended floor, roof landing , shelf & support balcony, lintel, sill band, beam, girder, bressumer, cantilever, stair case (except spiral stair case and landing) including preparing the top surface & finishing of nosing. (N) With out admixture, plasticiser (b) M-20 grade concrete ro prop.1:1.5:3
Providing and laying 25mm thick damp proof coarse with cement concrete in prop 1:1.5:3 with graded store agg. Stone of 10mm down nominal size including providing approved damp proof admixture in proparation of recommended by the manufacturer including curing etc.complete as directed.
112mm thick 1st class brick nogged wall in cement morter including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall (b) In cement mortar in proporation 1:4 (1 cement: 4 sand)
15mm thick cement plaster in single coat on rough side of single half brick wall for interior plastering upto 1st floor level including arrises, internal round angle not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. (A) On rough side (b) In cement mortar 1:4 (1 cement: 4 sand)
Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 corse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (a) 15mm thick.
65mm thick cement concrete floor consisting of 50mm under layer of cement concrete 1:3:6 of size (1 cement 3 coarse sand 6 coarse agg. Of size 25mm down) and 15mm thick wearing layer in cement concrete 1:1:2 (1 cement : coarse sand : 2 coarse agg of size 10mm down laid in panels and finished with a floating coat of neat cement finish (using cement slurry for boad @ 2.75Kg per sqm of floor area) including curring etc.complete as directed.
Providing fiting and fixing powder coated pressed steel door frame made of 1.25mm/1.6mm thick sheet of various sizes with necessary hinge jamb, lock jamb, head and steel base ties at the bottom of the frame. The whole frame shall be welded or rigid ly fixed togheter by mechanical means with base ties of pressed mild steel angle of size 20x20x1.25mm thick. Frame to be up with 1:4:4 PCC after fitting the frame with brick/concrete works etc. complete as directed for all levels. (PCC to be measured and paid for seperately) (b) 1.60mm thick sheet (ii) Size 105mm x 60mm (Single rebate)
Providing fitting and fixing factory mado Santro Flush door shutters having core & cross bands fabricated from seasoned 1st class timber, 25mm core battens.2.5mm to 3.5mm uniformaly thick cross bands style & rails made from hardwood timber of width not less than 50mm fixed to the door frames (chowkath) with necessary hings,screws,bolts etc as specified and directed at all levels (Door fixtures and fittings to be measured ann paid seperately) (b) 35mm thick.
Providing surface preparation for walls, ceilling etc, using average 1.50mm thick plaster of paries of pares including rubbing with sand paper filling gaps, depression etc. where necessary with chalk powder and plaster of pairs paste making the surface even and smooth complete at all levesl as specified and directed.
Finishing wall with two coats of acrylic emulsion exterior coatings of Unicem ''Rakshak'' brand required shade by thining 1ltr of paint with 750ml of water to give an even shade throughly brooming the surfaces to remove all dirt and remains of loose powdered materials as specified and directed by the department.
Supplying fitting and fixing pipes with all necessary fittings in exposed or in trenches and fefilling the same etc complete as directed. A) G.I pipe with GI fittings a) TATA/SAIL (medium) v) 40mm diameter.
Supplying fitting and fixing pipes with all necessary fittings in exposed or in trenches and fefilling the same etc complete as directed. A) G.I pipe with GI fittings a) TATA/SAIL (medium) iv) 32mm diameter.
Supplying fitting and fixing pipes with all necessary fittings in exposed or in trenches and fefilling the same etc complete as directed. A) G.I pipe with GI fittings a) TATA/SAIL (medium) iii) 25mm diameter.
Supplying fitting and fixing stop-cock of approved brand of size as mentioned and directed and specified (G.I & C.P pipes will be measured and paid separetely) I) Brass stop cock (heavy) of Sant make iv) 32mm dia.
Supplying fitting and fixing pump for 40mm dia tube well with all accessories complete as directed. i) Maya popular 6
Labour for boring hole for inserting tube well pipes through different soil/rockk media including hire charges of drill pipes,scaffolding,tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department. i) Bore hole of 150mm diameter
Supplying, fitting and fixing plain/bevel ended for casing, conforming to relevent IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign material in the annual space between the borehole and assembly pipes complete as directed by the Department. ii) PVC PIPE SUPREME/PRINCE/FUSION/SFMC Brand vi) 140m diameter
Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed. Ii. PVC PIPE SUPREME / PRINCE / FUSION /SFMC Brand iv. 75mm diameter
Supplying fitting and fixing ISI approved PVC filter 3.00 metre long. V. 150mm diameter
Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes (I) 2000 Lt capacity (a) Sintex make
Single phase Submersible motor pump set (Texmo / Crompton Greaves/ Aquatic/ CRI/ V-Guar suitable for 100 mm bore well and above. 1.5 HP STAGE 5 to 26 with control panel.
(E) CD WORK: RCC Box Culvert, Size=2.00m x 2.00m, 1 Ceel, 1 No. Earth work in excavation for structures as per drawings and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal up to a lead of 50m, dressing of sides and bottom and backfilling in tranches with excavated suitable material. I. Ordinary Soil (i) upto 3.00 m depth
Sand filling in foundation trenches as per drawing and Technical Specification Clause 305.3.9
Providing concrete for plain/reinforced concrete in open foundation complete as per drawing and Technical Specification Clause 802, 803,1202& 1203. B. With Natural gravel: I. PCC Grade M10 (i) Nominal Mix 1:3:6
Providing concrete for plain/reinforced concrete in open foundation complete as per drawing and Technical Specification Clause 802, 803,1202& 1203. B. With Natural gravel III. PCC grade M20 (i) Nominal mix (1:2:4)
Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications Clauses 802,804,805,806,807,1202 and 1204. B. With Natural gravel IV. RCC Grade M25 (i) Height up to 5m
Supplying, fitting and placing HYSD bar reinforcement(Fe 415) in sub structure complete as per drawing and technical specifications Clauses 1002, 1005, 1010 & 1202.
Providing and laying cement concrete wearing course M30 grade including reinforcement complete as per drawing and technical specifications Clause 800 & 1206.3 A. With Natural gravel :
Providing weep holes in brick masonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe through the full width of structure with slope 1V:20H towards drawing force complete as per drawing and technical specification Clause 614, 709, 1204.3.7
Back filling behind abutment, wing wall, return wall as per drawing and technical specification Clauses 1204.3.8 A. Granular Materials
Providing and laying curtain walls complete as per drawing and Technical Specifications Clauses 1304 III.Cement concrete grade M10
Construction of flexible apron 1m thick comprising of loose stone boulders weighing less than 25kg beyond curtain wall
(F) CD Work: H.P. Culvert, 1000mm dia, single row, 1 No. Earth work in excavation for foundation of structures as per drawings and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal up to a lead of 50m, dressing of sides and bottom and backfilling in tranches with excavated suitable material. I. Ordinary Soil (i) upto 3.00 m depth
Providing concrete for plain/reinforced concrete in open foundation complete as per drawing and Technical Specification Clause 802, 803,1202& 1203. B. With Natural gravel: I. PCC M10 (i) Nominal Mix 1:3:6
Bedding of pipe (i) Type A (Concrete cradle) Bedding laying concrete cradle bedding with M15 Grade Cement Concrete as per Clause 1105(i)
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. (B) 1000mm dia
Brick Masonary work in cement mortar in foundation of Head walls complete excluding pointing and plastering as per drawing and technical specification 1109 (A) Brick Masonary in 1:4 cement mortar.
Plastering with cement mortar (1:4), 15 mm thick on brick work in substructure as per technical specification.
(G) Earth Filling: Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary land compensation, Municipal gate fees if any monopoly duty etc. (profile meassurement to be taken and 12.5% deduction for shrinkage to be made from total quantuty) etc. complete as per directed and specified, including forest royalty within a distance of 8.00 km. (forest royalty shall be reimbursed on production of necessary certificate from the forest authority duly countersigned by D.F.O. concerned.
(I) Repair/Renovation of Club: Providing fitting and fixing fully glazed window with sash bars including oxidized M.S but hings (75mm x 60mm x 3.15mm) 2 Nos. on each leaf and 3 Nos on single leaf. (A) With Holock/Gamari/Bonsum wood. (ii) 35mm thick.
Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrough, framed and fixed in position in contact with C.C or brick masonary wall including supplying fitting and fixing with M.S hold fast (40mm x 3mm x 250mm) as per design embedded in cement concrete block in proporation 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonary as directed and specified. (b) With 1st class timber (Bonsum/Sundi)
Providing fitting and fixing full paneled doors/windows including oxidized M.S but hings (100mm x 75mm x 3.55mm) with necessary screws (other fittings to be and paid separately) (B) With 1st class local wood (gamari/Hollock/Bonsum) (ii) 35mm thick.
65 mm thick cement concrete floor consisting of 50 mm under layer of cement concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 25mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 (1cement :1 coarse sand : 2 coarse aggregate of size 10mm down) laid in panels and finished with a floating coat of neat cement finish (using cement slurry for bond @ 2.75 kg. per square metre of floor area) including curing etc. complete as directed.
Providing and fixing, in position suspended false ceiling using E-Grid (exposed ceiling suspension 2430 system) of grid size 600mm x 600mm/1200mmx600mm with main runner 38 x 24mm, cross tee 29mm x 24mm & wall angle 24mm x 24mm . Using 4mm/6mm thick High Pressure Steam Cured Non Asbestos Fibre Cement Board as per IS 14862, to be placed in a grid of G.I. system duly suspended with 4mm/6mm dia G.I/M.S bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures, air conditioning diffuser and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural soffit by hanger @ 1220mm maximum c/c. The last hanger at the end of each main runner should not be placed at more than 450mm from the adjacent wall. Flush fitting 1220mm cross tee to be interlocked between main runners @ 610mm c/c, so as to form 600mm x 600mm/1200mmx600mm grid, all complete as per the drawing & directions of engineer-in-charge. Finally, if specified, boards are to be painted with 2 coats of acrylic emulsion paint of approved shade/make over a coat of cement primer before installing it on the grid. (A) Standard Ceilings of Everest make or equivalent as directed by the departement (ii) Using 6 mm thick FC Board
15 mm thick Cement plaster in single coat on rough side of single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. A) On rough side b) In cement mortar 1:4 (1 cement 4 sand)
a) Removing white or colour wash by steel wire brushing and/or scraping sand papering and preparing the wall surface smooth including necessary repairs to scratches complete.
Providing two coats of acrylic water based wall putty/ wall filter of Asian Paints/Berger/ Dulux over concrete/cement plaster/brick walls and ceilling both internal and external after removing all the loosely adhering material from the wall/ceilling surface with the help of emery stone, putty blade or wire brush, moisterning the wall with the help of sufficient quantity of clear water as specified and directed by the department.
Wall Painting (two coats) with plastic emulsion paint of approved brand and manufacture (Asian/paint/Berger paint/ICI paint/J & N /Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a) Plastic Emulsion Paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J & N paint/Nerolac)
Applying one self- priming coat of acrylic emulsion paint of approved brand, thinning by adding water as per the specification of manufacturer over freshly plastered wall surface after throughly brooming the surfaces free mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth as specified and directed by the department. c) Asian paint
Finishing wall with two coats of acrylic emulsion exterior paint of approved brand of required shade, thinning by adding water as per specification of manufacturer after throughly brooming the surfaces to removed all dirt and remains of loose powdered materials as specified and directed by the department. c) Asian paint
Providing plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish.
Sri Dhiraj Borgoyary
THUNGRI KHAKLARY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .