Chief Manager Works
Replacing of Exterior Windows to Manufacturing Block at Helicopter Division HAL HC
TENDER NOTICE/NCP/78/26-27::HAL/FMD/R-78/26-27
TENDER NOTICE/NCP/78/26-27
Open Tender
Works
06MONTHS
Contract Section Civil-FMD-Bangalore
Refer Tender Document
₹0
₹90,600
15 Oct 2026
15 Oct 2026
5 Nov 2026
5 Nov 2026
23 Oct 2026
Name of the Individual / Firm / Company: * Mandatory
Type of ownership
Details of Constitution or Legal Status such as certificate of incorporation, shops and establishments, Contractor registration No etc.,
Address for correspondence:
PAN No.:
Goods and Service Tax ID No.
Contact details
Please Enter Contact person Name
Pls Enter Mobile No
Registered Contractor
Related Document to be Uploaded to eProcurement Portal * Category: E= 75 Lakhs - Lessthan= 100Lakhs F= 50Lakhs - Lessthan 75 Lakhs G = 25Lakhs - Lessthan 50 Lakhs H = 10Lakhs - Lessthan 25 Lakhs I = 5Lakhs - Lessthan 10 Lakhs J = 2Lakhs - Lessthan 5 Lakhs K = Lessthan 2Lakhs
I.T Returns for past 03 assessment years
Annual financial turn over during the last 3 years, ending 31st March 2025
TURN OVER IN Rs.
Pls Enter Turn over in Rupees for all the 3 years
ESI & PF Nos with proof
Remarks if any
Bank(s) details: [Copy of ECS and cancelled cheque leaf to be uploaded]
Related Document to be Uploaded to eProcurement Portal (Note Canceled cheque leaf to be uploaded)
Solvency Certificate Details
Pls Enter Details to 'Name of the Bank' , 'Date of Issue','Value in Rs
Experience of having successfully completed similar works during last 7 years ending on the previous day of submission of tender [Work experience certificate may be uploaded] (i) THREE similar completed works each costing not less than the amount equal to 40% of the estimated cost. (ii) TWO similar completed works each costing not less than the amount equal to 50% of the estimated cost. (iii) ONE similar completed work each costing not less than the amount equal to 80% of Amount put to the tender.
Type of Work: [ Incase of private works the same shall be supported with TDS certificate]
Please enter Details for Work No 1
Type of Work: [ Incase of private works the same shall be supported with TDS certificate]
Pls Enter Details for Work No II
Type of Work: [ Incase of private works the same shall be supported with TDS certificate]
Pls Enter Details for Work No III
Details of person holding the power of Attorney (If different from contact person)
Related Document to be Uploaded to eProcurement Portal
Pls Enter Details for Person holding Power of Attorney
DECLARATION I
DECLARATION II
Pls Accept the Delaration II
Specification
Demolishing RCC work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead, etc., all complete as specified and as directed by the Engineer-in-Charge.
Disposal of surplus excavated earth / moorum / building concrete / granite / wood / rubbish / malba / similar unserviceable, dismantled or waste material of partitions, ceiling boards, tiles, frames, etc., by mechanical transport including loading, transporting, unloading in all lifts / loads upt 10km distance from HAL, etc., all complete as specified and as directed by the Engineer-in-Charge.
Repair to plaster of thickness 12mm to 20mm in patches of area 2.50 Sq m and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, in any position and height with aid of stagging / scafolding, all tools and tackles including disposal of rubbish, etc., all complete as specified and as directed by the Engineer-in-Charge.
Providing & applying of 12mm thick cement plaster of mix 1:4 on concrete / brick wall with good finish for walls etc, complete. The quoted rate shall include all lead & lift, hire charges of machinery and equipments cost of all materials, labour charges and all other incidental charges, including scaffolding, curring, etc., all complete as specified and as directed by the Engineer-in-Charge.
Brick work 7cm thick with common burnt clay F.P.S. (non modular) brick of class designation 7.5 in cement mortar 1:3 (1 cement : 3 coarse sand) in superstructure above plinth level and upto floor five level, etc., complete, The quoted rate shall include all lead & lift, hire charges of machinery and equipments cost of all materials, labour charges and all other incidental charges, including scaffolding, curring, etc., all complete as specified and as directed by the Engineer-in-Charge.
Providing and fixing factory made 3 track UPVC glazed / wire mesh windows comprising of lead free uPVC multi-chambered frame, sash and mullion / coupler (where ever required) extruded profiles having minimum wall thickness of minimum 1.50mm and upto 2.10mm for Using R3 series with frame Approximate size of (98mm & above and upto 112mm) x (40mm & above & and upto 52mm) or nearest available, both glazed and fly screen sash Approximate size of (55mm & above and upto 66mm) x (30mm & above and upto 43mm) or nearest available, with zinc alloy (zamak) powder coated handle on every glazed panel along with suitable locking system (touch lock, etc.,), (Height upto 1.80m) conforming to EN: 12608 in any shape, white colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws, etc., Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded / mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water, etc., After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, etc., all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge.
UPVC glazed fixed type Ventilator with louvers of Approximate size [0.60 X 0.60]m using R1 series with frame Approximate size of (33mm & above) x (35mm & above) or nearest available & mullion (33mm & above) x (50 mm & above) or nearest available, if necessary. (Height upto 0.90 metre), etc., all complete as specified and as directed by the Engineer-in-Charge. Note:- The rate is including providing & fixing louvers and glass.
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with MS Flat [15 x 3]mm and nuts & bolts complete Stainless steel (grade 304) wire gauze of 0.50mm dia wire and 1.40mm aperture on both sides, etc., all complete as specified and as directed by the Engineer-in-Charge.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
detail.html
html • 0.05 MB
TN78.pdf
pdf • 0.63 MB
78TBF.pdf
pdf • 2.67 MB
78PQF.pdf
pdf • 0.20 MB
78PBF.pdf
pdf • 0.29 MB
78ECSForm.pdf
pdf • 0.48 MB
78UNDERTAKING.pdf
pdf • 0.57 MB
78CHECKLIST1.pdf
pdf • 0.19 MB
78PQ.xlsm
xlsm • 0.03 MB
78PB.xlsm
xlsm • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .