| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.8 LAccepted-AOC HO SR NO 73 TAPKIR MALA CHOWK TAPKIR NAGAR KALEWADI PIMPRI PUNE 411017 | PUNE | MAHARASHTRA | 411017 | L1 | Accepted-AOC Lowest amount quoted | |
| 2 | L2₹48.5 L+₹6.2 L (14.7%)Rejected-Finance MAIN ROAD RANJHI JABALPUR 482005 M P | JABALPUR | MADHYA PRADESH | 482005 | L2 | Rejected-Finance Highest amount quoted |
Tender Value
Refer Docs
EMD Value
₹97,000
Closing Date
10 Oct 2020, 6:00 pmClosed
Shri B M Verma, IDSE, EE(SG)
Garrison Engineer (East), Near COD Estate, Ranjhi, Jabalpur (MP)-482011
As per BOQ
2020_MES_376313_1
8288/E8
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
Garrison Engineer (East) Jabalpur
D b(i) / a(ii)
9 documents required · 9 mandatory
₹500
Garrison Engineer (East) Jabalpur
₹97,000
Yes
27 Oct 2020
10 Sept 2020
13 Oct 2020
10 Sept 2020
10 Oct 2020
25 Sept 2020
10 Sept 2020 - 24 Sept 2020
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets etc and making good disturbed surfaces of walls, floors, as per existing finishes etc complete all as specified.
Taking down carefully unserviceable/partly unserviceable light fittings any type, tube light fittings and fixtures, etc, and making good to the disturbed surfaces of walls/floor etc to macth with existing surfaces including white washing/colour washing/distempering to match with existing wall/floor/ceiling finishes complete all as specified and directed.
Taking down serviceable/unserviceable electric meter including meter box from existing position carefully for refixing adjacent to main switch board including making good to disturbed surfaces to match with existing surfaces
Fixing only serviceable electric meter on & including wooden board to the wall and including making good disturbed surfaces to match with the existing surfaces complete all as specified.
M&L for the following point wiring with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sq mm (FRLS), with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sq mm (FRLS) stranded for earth continuity wire, to be drawn in and including, PVC medium grade conduit not less then 20 mm dia with MS sheet metal sunken switch/Terminal box 1.2 mm thick and hylam switch board cover 3.0 mm thick or PVC moulded switch board and brass screws with cup washers including all necessary wall cutting and making good disturbed surface all as directed and specified Make of cable - FINOLEX / PLAZA / HAVELLS/POLYCAB & Make of PVC conduit & conduit accessories - PLAZA / FINOLEX/ KALINGA. Note : (i) Making good to match with the adjoining surface shall be included in the quoted rate. (ii) Rate shall be included for Cutting/chases of wall/floor/ceiling
-ditto- all as per item No 5 above but One light point controlled by one way switch
-ditto- all as per item No 5 above but One ceiling /exhaust fan point controlled by one switch and regulator
-ditto- all as per item No 5 above but One 3 pin 5 amp socket out point on the same board with other switches.
-ditto- all as per item No 5 above but One 3 pin 5 amps socket out let point on independent board
-ditto- all as per item No 5 above but One bell/buzzer point controlled by one bell push.
-ditto- all as per item No 5 above but One light point controlled by two 2-way switches
-ditto- all as per item No 5 above but for one socket outlet 15 Amp on independent board with 2.5Sqmm (FRLS) cable and 1.5 Sqmm (FRLS) earth wire.
S &F Switch piano flush type single pole one way 5 amps.
S &F Switch piano flush button type Two way 5 amps.
S &F Socket out let 2 in one, 5/3 pin 5Amp
S &F Switch socket combination 5 Amps 5 pin flush type
S &F Switch socket combination 5 in 1, 5 pin 5/15 Amps flush type universal .
S &F Ceiling rose, surface bakelite 65x50 mm three terminal
S &F Call bell AC-230 Volt single pole ding dong
S &F Bell push, flush type 5 Amps.
S &F Electronic regulator 100/120 Watt step type
S &F Lamp holder insulated body with back plate for angle holder all as per specified
Note :- for Item No-13 to 22 Make : Havells/Anchor/Leader
S &F LED tube light fittings decorative ultra slim linear fixture with extruded with heat sink envioromentel friendly Energy efficient ready to use pack ,1x20/18 Watt ,4 feet,surface mounting type extruded pvc, snap on installers and domestic electronic Driver ,connector block etc.with all assoceries intenallt prewired & includingconeecting up with 2 core flexible cppper conductor cable with sutable size & suitable for and mounting clamps PVC squre box 75x75mm - 2 nosetc. Make- PHILLIPS/WIPRO/BAJAJ/HAVELLS/CROMPTON
S&F LED light fittings decorative 34/36 Watt surface mounting type extruded metal/aluminium body, and electronic LED driver, connector block etc. with all accessories internal prewired & including connecting up with 2 core flexible copper conductor cable with suitable size and mounting clamps etc complete all as specified and directed of Make Phillips Cat Pt No SM365C LED 32-65 PSU OD GR, or Wipro Cat Pt No CRCO10S036HP57G1 or Crompton Cat Pt No LCTLSN-36-CDL, or Havells Cat Pt No LHEWEBP7IL1W036.
S &F LED tube light fittings decorative ultra slim linear fixture with extruded with heat sink envioromentel friendly Energy efficient ready to use pack ,1x10 Watt ,2 feet,surface mounting type extruded pvc, snap on installers and domestic electronic Driver ,connector block ect.with all assoceries intenallt prewired & includingconeecting up with 2 core flexible cppper conductor cable with sutable size & suitable for and mounting clamps PVC squre box 75x75mm - 2 nosetc. Make- PHILLIPS/WIPRO/BAJAJ/HAVELLS/CROMPTON
Supply and fix LED building security light fitting of 45 watt, aluminium pressure dia cast IP 66 with high power LED & LED driver of Make- PHILLIPS/WIPRO/ BAJAJ/ HAVELLS/ CROMPTON
Supply & fix GI pipe bracket 25mm Bore- 0.9m long & 2 set of clamps made out of 30x5mm ms flat & fixed with anchor bolt suitable for 45w security light fitting including taking down of old bracket complete all as specified.
S &F in repairs earth enclosure with 2 pin earth plug sokcet complete with MCB SP 20/25 amp,flush mounting type LEGRAND/ABB/L&T
Dismantling unserviceable main switch/ kitkat DBs/ MCB including wooden board from existing position and making good disturbed surfaces of wall to match with existing surfaces
S& F MCB DB made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, IP-43-IK09 protection grade , 415Volts TPN with 4 way Double door , L&T / LEGRAND / SCHNEIDER
S& F MCB DB made of sheet steel, powder painted with bus bar 200 A, neutral link, earth bar and Din rail , 230 Volts SPN with 4 way Double door IP-43-IK09 protection grade, L&T / LEGRAND / SCHNEIDER
S& F MCB DB made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, earth bar and Din rail ,230 Volts SPN with 8 way Double door , IP-43-IK09 protection grade,L&T / LEGRAND / SCHNEIDER
S& F MCB DB made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, earth bar and Din rail , 230 Volts SPN with 12 way Double door IP-43-IK09 protection gradeL&T / LEGRAND / SCHNEIDER
NOTE FOR ITEM NO 25-28 -(1).The unit rate includes for cutting the brick walls to accommodate DB to make flush to wall./ DB tobe fixed on wall including frame made out of MS flat 40x5mm(2).The unit rate includes for making good the disturbed surfaces including finishes to match with the adjoining surface (3) MAKE OF DB & MCB -L&T / LEGRAND / SCHNEIDER
M&L in repairs for Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 4 Sqmm (FRLS), earth continuity conductor of size 2.5 Sqmm (FRLS) to be drawn through in and including non metallic PVC conduit medium grade 25 mm dia with fittings (ISI marked) fixed on walls/roof/floors including Taking down old sub main wiring with conduit of any size/capacity including conduit and making good disturbed sufaces to match with the existing surfaces all as directed by Engineer in Charge. Notes:- Two wires of 4 sqmm and one wire of 2.5 sqmm & PVC conduit shall be measured as one unit.
M&L in repairs for Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 6 Sqmm (FRLS), earth continuity conductor of size 4 Sqmm (FRLS) to be drawn through in and including non metallic PVC conduit medium grade 25 mm dia with fittings (ISI marked) fixed on walls/roof/floors including Taking down old sub main wiring with conduit of any size/capacity including conduit and making good disturbed sufaces to match with the existing surfaces all as directed by Engineer in Charge. Notes:- Two wires of 6 sqmm and one wire of 4 sqmm & PVC conduit shall be measured as one unit.
S&F in repair of service connection cable using PVC insulated unsheathed, aluminium conductor cable 2 core of size 10 Sq mm, of standred nominclature follow SEI normes all as directed by Engr-in-Charge.
M&L in repairs for Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 10 Sqmm (FRLS), earth continuity conductor of size 6 Sqmm (FRLS) to be drawn through in and including non metallic PVC conduit medium grade 32 mm dia with fittings (ISI marked) on walls/roof/floors all as directed by Engineer in Charge.Notes:- (i)Two wires of 10sqmm and one wire of 6 sqmm & PVC conduit shall be measured as one unit.
S&F in repairs MCB TPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 63Amps complete all as specified
S&F in repairs MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 63Ampscomplete all as specified
S&F in repairs MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 6-32Amps complete all as specified
S&F in repairs MCB SP 6-32 Amps 'C' series, breaking capacity 10 KA of rating complete all as specified
NOTE FOR ITEM NO 40-43 - MAKE OF MCCB & MCB -L&T / LEGRAND / SCHNEIDER
M& L For Earthing complete with galvanized steel earth plate electrode 600mm x600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized earth wire 4.00mmdia by means of bolts ,nuts ,check nuts and washers complete up to and including test point made out of 40 x 6mm alum flat including earthing pit , charcoal common salt ,Earthing lead 4.00mm dia up to 7.5m, 20mm dia medium grade GI watering pipe ,G.I. protection pipe 15 mm dia up to 7.5m long,,PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate ,PCC pit cover including earth work complete all as shown in electrical plate No-5 of SSR-1991 (part-I)
Refixing of servicable MCB any type or size
Taking down partly unservicable tube light fittings any type,and fixtures, etc, and Refixing the same after repair
S&F in repairs LED bulb of 9 Watt Make of bajaj / crompton / Phillips
S&F in repairs LED tube rod of 18/20 Watt suitable for repair/replacement of conventional flourocent light of Make of bajaj / crompton / Phillips
S&F in repairs LED Batten suitable for 18/20 Watt led suitable for repair/replacement of conventional flourocent light of tube Make of bajaj / crompton / Phillips
S&F infra red light sensor (Ceiling mounted) with adjustable dusk to down setting to sense motion and direct wheather human has moved in or out of the sensor range time delay control min 10 sec plus minus 5 sec, max plus minus 2 min adjustable, light label control 5 lux to 2000 lux, rated load 1100 watt (incandscent), 550 watt halogen or 250 watt LED complete with testing complete all as directed by Engr-in-Charge.Make Phillips, Bajaj. Havells, L&T
S&F in repairs LED bulb of 12 Watt Make of bajaj / crompton / Phillips
S&F in repairs Surface mounting round, decorative LED down lighter 12 WATT and transulent defuser, prefixed with flat profile and mounting clamps etc., complete all as specified Make Phillips Cat Pt No SM250C LED12S- 6500 PSU WH,or Wipro Cat Pt No LD-141-XXX-65-XX*, or Havells Cat Pt No LHEJNP5CPZ1W012
S&F in repairs extention board with two 15 A Socket and two 5A socket using wire for extention of size 6 sqmm copper multistranded wire, length should not less than 5 Mtr all as specified and directed by Engr-in-Charge.
S&F in repairs for LED tube light fittings decorative ultra slim linear fixture with extruded with heat sink envioromentel friendly Energy efficient ready to use pack ,1x20/18 Watt ,4 feet,surface mounting type extruded pvc, snap on installers and domestic electronic Driver ,connector block etc.with all assoceries for replacement of 28/36 watt FTL all as specified and directed by Engr-in-Charge. Make- PHILLIPS/WIPRO/BAJAJ/HAVELLS/CROMPTON
S&F in repairs PVC rectangular block of size 175 x100 x50mm for mounting switches,sockets/fan Reg,etcwith 3mm thick plastic laminated sheet cover
S&F in repairs PVC rectangular block of size 200 x150 x50mm for mounting switches,sockets/fan Reg,etcwith 3mm thick plastic laminated sheet cover
S&F in repairs PVC rectangular block of size 250 x200 x50mm for mounting switches,sockets/fan Reg,etcwith 3mm thick plastic laminated sheet cover
S&F in repairs PVC rectangular block of size 350 x300 x50mm for mounting switches,sockets/fan Reg,etcwith 3mm thick plastic laminated sheet cover
S&F in repairs Switch socket combination 5 in 1, 5 pin ,15 Amps flush type universal .Make : Havells/Anchor/Leader
S&F in repairs Switch socket combination 5 Amps 5 pin flush type Make : Havells/Anchor/Leader
S&F in repairs Switch piano flush type single pole one way 5 amps. Make : Havells/Anchor/Leader
S&F in repairs 1.5 sqmm flexible wire with copper multistrand conductor Make Finolex/Havells/RR kabel/Plaza
S&F in repairs 2.5 sqmm flexible wire with copper multistrand conductorMake Finolex/Havells/RR kabel/Plaza
S&F in repairs 4.0 sqmm flexible wire with copper multistrand conductor Make Finolex/Havells/RR kabel/Plaza
S&F in repairs heating element 1500 watt trangular type make of Bajaj / Tosiba / Havells all as specified and directed by Engineer –in-Charge
S&F in repairs heating element 2000 watt trangular type make of Bajaj / Tosiba / Havells all as specified and directed by Engineer –in-Charge
S&F in repairs Electronic regulator 100/120 Watt step type Make : Havells/Anchor/Leader
S&F in repairs ding dong call bell Make : Havells/Anchor/Leader
Supply and hanging in replacement 1200mm sweep ceiling fan BEE 5 star rated of colour as approved by GE with double ball bearing, 350-370RPM, 220/240 volts, AC 50 Htz power consumption shall be within the norms under standard test condition along with down rod, canopy and all accessories all as supplied by manufacturer and connecting up with & including of PVC insulated and sheathed three core FRLS copper conductor flexible cable of size 16/0.20mm of sufficient length complete all as specified and directed. Make: Crompton Cat part No. HS Plus- 5 Star or equivalent model of make- Havells or Khaitan or Usha or Bajaj as approved by GE. Note :- old fans shall be deposited to CDA
Supply and fixing in replacement 300mm sweep wall mounted fan of colour as approved by GE with high performance motor, thermal overload protector (TOP) helps in protecting the motor in case of any high voltage fluctuation, aerodynamically designed, operating voltage 220-240 volts, AC 50 Htz complete with and all accessories all as supplied by manufacturer and all necessary nuts, bolts etc of suitable shape and size for fixing to wall as directed & making good the disturbed surfaces as per existing specifications and necessary connections complete all as specified and directed. Make: Havellsor Crompton or Khaitan or Usha or Bajaj as approved by GE. Note ; old fans shall be deposited to CDA
Supply and set in replacement 400mm sweep table fan of colour as approved by GE with high performance motor speed 1360 RPM having 3 Nos motor speed for better air delivery, thermal overload protector (TOP) helps in protecting the motor in case of any high voltage fluctuation, aerodynamically designed & balanced blades, operating voltage 220-240 volts, AC 50 Htz complete with and all accessories all as supplied by manufacturer and necessary connections complete all as specified and directed. Make: Havells model-Swing ZX or equivalent model of make- Crompton or Khaitan or Usha or Bajaj as approved by GE. Note ; old fans shall be deposited to CDA
Taking down and dismantling of ceiling fan, segregation of unserviceable parts, cutting and removing out copper winding, cleaning the armature, rewinding of fan armature with appropriate gauge of super enamelled copper wire with necessary insulating materials such as vertex paper, cotton tape, PVC insulation tape etc varnishing with approved grade of insulation varnish and heating up, re-assembling the fan complete with replacement of unserviceable spares parts, (spareparts will be measured & paid separately) including necessary lathe work for fixing of bush/bearing greasing the same with approved grade of grease, making all electrical connection and supply and fixing the following items and including necessary transportion to workshop, for 1200/1400/1500mm sweep fan :- (i) Split pin - 02 Nos, (ii) Connection block - 1 No, (iii) Insulation rubber bush. - 01 No
Supply and fixing of foam effect nozzle (water level dependent) constructed of machined cast bronze natural finish Model No PF- 3450, nozzle length 152mm (6"), jet orifice - 25mm, 5 meter spray height complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement of Cosmos LED flood light with high power COB LED , Protection Class IP66 of Capacity 60 Watt complete all as specified and directed Make- PHILLIPS/ WIPRO/ BAJAJ/ HAVELLS/ CROMPTON
Relaying old dismantaled Bricks covering with width equal to length of bricks as mechanical protection to cable complete all as specified and as directed.
Fixing or hanging only ceiling fan after winding fan under item No. 01 above and connecting up including provision of 3 core 1.5 Sqmm cable from ceiling rose or connector to fan( max up to 1m length) all as specified and directed
Overhauling of ceiling fan of any make and sweep after opening and cleaning rotor bearing and stator properly and oiling/greasing of bearing/ bushes, reassmbling the same, fixing and coonecting on its existing position and testing on completion all as specified and as directed including taking down.(Note- (A) Overhauling of ceiling fans will be carried out at AGE E/M Yard only. (B) The spares required shall be measured and paid separately in the relevant items).
M & L For Painting of ceiling fan 1200/1400 mm sweep complete including fan blade down rod with synthetic enamelled paint of white tint including cleaning and removing dust and dirt and making smooth surface for painting including writing MES No complete all as specified.
S & F in repairs Mild steel work in framed work such as Fan hooks, Clamps, gratings, ladders etc., with ends of bars welded and/ or riveted, or forged and similar work confirming to Fe 410 - O or Fe 310 - O and incl painting to surfaces using two coats of metallic primer and a coat of synthetic enamelled paint of desired colour as directed.
S&F in repairs post of lantern fitting made out of black ABS plastic spigot & spun alluminium funnel shaped with clear acraylic cover suitable for 1x20/25w LED lamp including fitting complete all as specified. Make- PHILLIPS/WIPRO/BAJAJ/HAVELLS/CROMPTON
S&F in repairs garden light 45 Watt warm white LED post top with decorative circular design compliant to dark sky norms, with polycorbonate opal diffuser and IP 65 protection of Bajaj Cat Pt No BGCP 45W LED WW or equivalent of Philips/WIPRO/Crompton
Febricate supply & fix in repairs sign board mentioning Office of CDA, Jabalpur of size 2 x 1 meter with inbuilt lighting arragment with standred capital letters all as specified and directed by engr-in-Charge.
S& F in repairs MCCB DB VERTCLE TYPE made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, IP-43-IK09 protection grade , 415Volts TPN with 4 way Double door , L&T CAT NO-DBVTL004DD/ LEGRAND CAT NO-607913/ equivalent of ABB
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr deep and getting out in soft loose soil all as specified and directed
Returining, filling in including spreading, levelling watering and well ramming in layer not exce 25 cm, all as specified and directed
Removing excavated soil to a distance not exce 50 mtr and deposited where directed at a level not exceding 1.5 mtr abvoe the starting point all as specified and directed.
M&L for run lead joints for the following size of pipes complete for water mains with spigot & socket pipes and fittings complete all as specified and directed:-
150 mm bore
100 mm bore
80 mm bore
S&F rubber gasket joint for flanged end pipe & fittings of following size :
150 mm bore
100 mm bore
80 mm bore
S&F machanical Gypsum joint ISI marked for spigot end pipe of following sizes:-
150 mm bore
100 mm bore
80 mm bore
S&F 80 to 300mm bore spigot/flanged/ socketed CI fittings. such as bends (any type radius and angle), apers, tees, collars & tail piece socket/flanged/spigot etc complete all as specified.
Dismantling/taking out unserviceable sluice valve of size 80mm to 300mm bore dia by opening/cutting rusted nuts, bolts etc all as specified and directed.
S&F the following CI sluice valves both ends flanged and drilled, bonnet wedge stuffing box. Gland trust plate, hand wheel made out of grey CI, complete valve confirming to IS 14846/2000 and its fittings suitable for hydraulic test pressure of 15 Kg/sqcm PN 1.0 ISI marked complete all as specified and directed :- Make : Kirloskar/L&T/Upadhyay
80 mm bore
100 mm bore
S&F the following CI sluice valves both ends flanged and drilled, bonnet wedge stuffing box. Gland trust plate, hand wheel made out of grey CI, complete valve confirming to IS 14846/2000 and its fittings suitable for hydraulic test pressure of 15 Kg/sqcm PN 1.6 ISI marked complete all as specified and directed :- Make : Kirloskar/L&T/Upadhiya
150 mm bore
Cutting of road /hard standing for laying /dismentling of pipe line and making good surfaces matching with the existing surface after laying of pipe line.up to 30 cm
Taking up or down the following old unserviceable GI Tubing and connections including cleaning for refixing:- Note :- Excavation/earthwork shall be measured & paid separately.
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Refixing the following old GI Tubing and connections in New or old position (walls, Ceiling, Floors etc) of sizes:-
15 mm bore
20 mm bore
25 mm bore
40 mm bre
Laying only the followiing old serviceable removed GI Tubing from site and connection in New or old position (in trenches) of sizes :-
20 mm bore
25 mm bore
40 mm bore
50 mm bore
S&F the followiing GI tubing medium grade with all fittings and fixed complete laid in trenches of size :-
20 mm bore
25 mm bore
40 mm bore
50 mm bore
S&F the followiing GI tubing medium grade with all fittings complete to walls and ceilings or laid in floors of size :
15 mm bore
20 mm bore
25 mm bore
40 mm bore
Taking down/removing the following Unserviceable Gate valve/stop valve from water supply lines, closing the opening with plug or preparing for new as required necessary fittings complete all as specified.
20 mm bore
25 mm bore
40 mm bore
50 mm bore
S&F the followiing Gun metal Globe or Gate valve with iron wheel head, screwed both ends for iron pipe and fixed with required necessary GI fittings complete :- Make : Kartar/Zolto/Sant/Leader
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Cutting the following existing galvanised iron pipe in position for insertion of new pipe/tees, branches etc.
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
100 mm bore
Taking up Submersible Pump assembly including column pipe approx 50 to70 mtrs using chain pulley block manually and carrying out following phase of work all as directed for 17.5HP/15 HP Pump Set .(i) Transportation of submersible pump -motor assembly for necessary repair. (ii) Carrying out overhauling of motor assembly 3phase ,taking out burnt winding wire, with & including PVC insulated water proof copper wire with winding wire of appropriate gauge and turn, providing insulation materials and replacement of bearing and assembling with repaired/serviceable pump and testing complete all as directed by Eng-in Charge. (iii) Carrying out dismantling and overhauling of multi stage pump, incl cleaning and derusting of casing, replacement of worm out spare like bearings, impellar bushing, coupling etc & refixing of existing serviceable components after proper cleaning, machining all as required & assembling testing at workshop complete for 17.5/15 HP submersible pump of any make including carrying out painting by two coats of synthetic enamelled paint over a coat of primer,assembling the pump and motor including testing complete all as specified and directed. Note : Spare parts shall eb measured and paid separately as supply only
Supply only Adopter
Supply only Balancing Ring
Supply only Base plate
Supply only stud
Supply only Bearing Bush
Supply only Bearing housing lower
Supply only Bearing housing upper
Supply only Bearing housing lower open type
Supply only Bearing housing upper open type
Supply only CI Bearing
Supply only coupling
Supply only coupling key
Supply only Drain plug
Supply only Flange lower
Supply only Flange upper
Supply only Flange lower stud
Supply only Flange upper stud
Supply only Gronmet
Supply only motor Base
Supply only MS washer
Supply only Ny lock nut
Supply only Plug washer
Supply only Pressure cup Equeliser
Supply only RT disc
Supply only Rocker
Supply only Rotor clip
Supply only Rotor Dowl pin
Supply only Rotor nut
Supply only Rotor sleev
Supply only Stand guard
Supply only Stater circlip
Supply only stud O ring
Supply only TB axel
Supply only T bolt
Supply only T bolt housing
Supply only water seal
Supply only water seal O ring
M&L for Rewinding the motor with super enamelled copper winding wire with appropriate same gauge of exsisting coil with similar class of exsisting insulation as recommended by manufacturer with high quality normex insulating paper applying best quality insulating varnish on stator/rotor windings drying them completely, testing the insulations as directed by engr-in-charge. Make : Atlas/ BWC/ Swastik/ Chetak
S&F in replacement the following stainless steel spindle suitable for following dia of sluice valve complete with stainless steel nut and threading as per sample & directed by engr-in- charge
150 mm bore sluice valve
100 mm bore sluice valve
80 mm bore sluice valve
Supply, testing connecting & jointing in repairs PVC insulated, PVC Sheathed submersible flexible cable of size of 10 Sqmm 3 core standard copper conductor 1100 Volt grade including water proof jointing for making connections to water pump and starter complete all as specified and directed
Supply and lay in repairs 80 mm bore GI column pipe heavy grade ISI marked in standard length of 3 meter each duly threaded with both ends with and including long threaded heavy duty socket and fittings and lowering into well including supplying, lowering ,fixing, commissioning & testing complete all as specified and directed
Supply and fix in repairs CI non return valve with by pass arrangement of size 150 mm bore complete all as specified.
M&L in repairs Fully Automatic Star Delta Motor starter 15 HP in sheet-steel enclosure type MK-1 .feature (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) and Relay Range 11-18 complete all as specified. (Make : L&T cat no SS 96257 or Equivalent OF SIEMENS/schneider)
Supply only ALTOCH - GP (Calcium based granular disinfectant for water treatment, more stable than Chlorine Gas, and stronger than bleaching powder, and sodium Hypochlorite) packing in 45 kg drum completed all as specified & directed by Engr-in-Charge. Make : Daclibak, Potter & Watt Corporation or equivalent from E in Cs approvals.
M&L for draining out water from OH reservoirs of 100000 gallons capacity not exc. 18 Mtr head/staging, and cleaning internal portion of tank (bottom and walls) by means coir / wire brush etc. and wash the internal portion of tanks by using bleaching powder @ 25 grams per 1000 Ltrs of water after removing sludge and mud etc to a distance not exc 50 mtr including applying one coat of synthetic enamel paint on all steel surfaces such as ladder, railing, inlet & over flow CI pipes connected sluice valves of the respective OH tanks/ground level reservoir etc writing letters with white paint (date of cleaning and capacity of tank) on black painted surface of tanks complete all as specified and directed by Engineer-in-Charge.
Supply & Fix in replacement of 1.5 HP mono block pump with complete fitting, single phase, 230 Volts all as specified and directed by Engr-in-Charge Note ; old fans shall be deposited to CDA
S&F in replacement Digital water leval indicator system 150 mm size digit direct display,operated on 230v Ac, suitable for upto 20 metre height over head Reservior/underground sump of any capacity, preadjustable alarm for upper & lower level, temp range -5 to 50 degree, humidity up to 90% RH, reset push switch for silent the alarm including 4 core 1.5 sqmm copper cable. MAKE: SURYA ELECTRONICS & CONTROLS / RECTRONIC DEVICE & CONTROLS
Dismantling of existing valve pit and M&L for construction of masonry valve pit (as per drawing No CEJZ/TD/819/91 dated 16/04/91) with the following specification:- Brick work in CM (1:4) with sub class 'B' bricks, 15mm thick plastering in CM (1:4), PCC (1:4:8) type D-2 in foundation, chamber of internal size 1200 x 1200x1200 mm,150mm thick copping on top in PCC (1:3:6), type C-1, 3mm thick MS sheet for cover, angle iron 40mmx40mmx5mm for frame all around with suitable handle with locking arrangement including two coats of synthetic enamel paint over a coat of red oxide primed on MS work and three coats of white wash and preparation of surfaces complete all as specified and shown on drawing
Supply and install steel, tubular swaged poles complete with cast iron base plate, finial taper plug nuts and taper plug , bolts, nuts and screws as specified type 410-SP- 31 (9.0 m long) complete all as specified and directed. Note : Excavation, earth work shall be measured and paid separately.
Dismantling of existing u/s steel/PCC LT poles of any size & type from its position carefully and removing from the site and including necessary excavation and earth work in any soil/strata, demolition of concrete, disconnection of conductor from pole etc. complete all as directed.
M&L for Plain cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation of poles etc complete all as specified.
M&L for Plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete for stays,foundation and platform for transformer installation complete all as specified.
M&L for Plain cement concrete (1:3:6) type C-1 using 20 mm graded stone aggregate for coping of pole with and including formwork complete all as specified and directed.
S&F in repairs 1100 Volts grade line composite phase separators, moulded & bolted type as per IS 1445 - 1997 suitable for the following :-
Taking down u/s LT U/G cable (including all mounting accessories, bricks and sand etc ) from trenches, wall, floor etc and removing to store for safe custody upto 25 sqmm complete all as specified and directed. Note:- Excavation for taking out cable will not paid for separately, the cable shall be deemed to have taken down from the trenches excaveted for laying of cables.
Taking down u/s U/G cable (including all mounting accessories, bricks & sand etc) from trenches, wall, floor etc and removing to store for safe custody above 35 upto 95 Sqmm complete all as specified and directed. Note:- Excavation for taking out cable shall not be paid separately, the cable shall be deemed to have taken down from the trenches excaveted for laying of cables.
S&F XLPE insulated armoured and PVC sheathed "heavy duty" electric cable with aluminium conductor 1100 volts grade laid in trenches, passing through pipes /ducts including testing complete of following cross sectional area of the following sizes:- Note:- Rate is inclusive of cable gland & cable lugs. The contractor shall be used old cable route indicator retrietive from item above. Fixing cost for the same shall be included in the quoted rates of these items. Make : Havells/GLOSTER/Poly Cab/Paragon
2 core, 4 sqmm cross sectional area
2 core, 6 sqmm cross sectional area
2 core, 10 sqmm cross sectional area
4 core, 16 sqmm cross sectional area
3-1/2 core, 25 sqmm cross section area
3-1/2 core, 35 sqmm cross section area
3 -1/2 core, 50 sqmm cross sectional area
3 -1/2 core, 70 sqmm cross sectional area
3 -1/2 core, 95 sqmm cross sectional area
S&F in repairs 40mm bore, GI steel tubing "light grade" for cable protection passing under road /floor or for fixing to poles complete all as specified and as directed Make :- JINDAL/ ZENITH/ TATA/ PRAKASH
S&F in repairs 50mm bore GI steel tubing "light grade" for cable protection passing under road /floor or for fixing to poles complete all as specified and directed Make - JINDAL/ ZENITH/ TATA/ PRAKASH
S&F in repairs 80mm bore GI seel tubing "light grade" for cable protection passing under road /floor or for fixing to poles complete all as specified and directed Make - JINDAL/ ZENITH/ TATA/ PRAKASH
S&F in repairs RCC hume pipe for road crossing of cables class NP-2 of size 100 mm dia complete all as specified.
Cutting of hardstanding/ Road for laying of pipe line/cable and making good surfaces after lying of pipe line/ cable upto 30cm in depth as per existing specification complete all as specified and directed.
M&L for boring of hole under road/hard standing by trenchless technology including S & F HDPE pipe "heavy duty " of size 100mm bore fixed in repairs complete all as specified and directed.
M&L unwashed Sand cushioning to under ground cable provided with a layer of 8 cm deep before laying and 15 cm covering above the top edge of cable after laying complete all as specified. Note : Measurement shall be done after puning down of sand.
M&L Brick covering with width equal to length of bricks as mechanical protection to cable with well burnt sub class `B` old size bricks laid dry and flat complete all as specified and as directed.
Taking down of faulty LT UG cable of size upto 3.5x120 Sqmm from trenches /pole/wall etc for detecting fault including repair and jointing at site including relaying at the same location complete. Note:- Excavation/earth work and cable jointing & jointing kit shall be measured and paid separately under relevent item of schedule.
S&F LT Joint cable, jointing kit straight through joint heat shrinkable type of size 10 Sqmm 4 core to 16 Sqmm 4 core cable size complete all as specified and directed. Make : M Seal/ Denson/Reychem/Cab seal
S&F LT Joint cable, jointing kit straight through joint heat shrinkable type of size 25 sqmm 3.5 core to 50 sqmm 3.5 core cable size complete all as specified and directed. Make : M Seal/ Denson/Reychem/Cab seal
S&F LT Joint cable, jointing kit straight through joint heat shrinkable type of size 70/ 95 sqmm 3.5 core cable size complete all as specified and directed. Make : M Seal/ Denson/Reychem/ Cab seal
Taking down partly unserviceable/unserviceable security/street/gate/flood light fittings from poles/towers/Perimeter Fencing of any type upto 9 m height by manual or mechanical means and for necessary repair and make srviceable as per complaint given by department (E/M service cell) through job card/complaint register on day to day basis all to the satisfaction of Engr in charge & complete all as specified and directed. Note :- Ballast, Lamp holder, capacitor, ignitor, covers and lamps of required wattage/type shall be measured and paid separately.
Fixing only repaired serviceable fitting of any size, and any make complete all specified and directed by Engr-in-charge
S&F in repairs Lamp holder porcelain suitable for street light fitting Screw type E-40 base Make: Bajaj/Havells/Crompton
S&F in repairs Lamp holder porcelain suitable for street light fitting Screw type E-27 base Make: Bajaj/Havells/Crompton
S&F in repairs LED Lamp 40/45 watt type Retro fit E-22 base Make: Bajaj/Wipro/ Khaitan/ Syska/ Crompton
S&F in repairs LED Lamp 30/35 watt type Retro fit E-22 base Make: Bajaj/Wipro/ Khaitan/ Syska/ Crompton
S&F in repairs LED Lamp 20/25 watt type Retro fit E-22 base type Make: Bajaj/Wipro/ Khaitan/ Syska/ Crompton
Taking Down of street light Bracket including clamps of any type/any size from to pole/wall including necessary nut & bolts as directed complete all as specified and directed.
S&F GI pipe bracket made of light Grade tubing of size 40 mm bore, duly bended by hot forgoing length 1.20 mtr including two sets of clamps made of 30mm x 5mm thick Flat iron with GI bolt,nuts & washers complete all as specified and directed
S&F GI pipe bracket made of light Grade tubing of size 32 mm bore, duly bended by hot forgoing length 1.20 mtr including two sets of clamps made of 30mm x 5mm thick Flat iron with GI bolt,nuts & washers complete all as specified and directed
S&F LED street light lumanaries of size 90 W pressure die cast aluminium housing with heat resistance toughed glass & IP66 protection complete all as specified and directed Make- PHILLIPS/WIPRO/BAJAJ/HAVELLS/CROMPTON
S&F LED street light lumanaries of size 72 W pressure die cast aluminium housing with heat resistance toughed glass & IP66 protection complete all as specified and directed Make- PHILLIPS/WIPRO/BAJAJ/HAVELLS/CROMPTON
S&F LED street light lumanaries of size 60 W pressure die cast aluminium housing with heat resistance toughed glass & IP66 protection complete all as specified and directed Make- PHILLIPS/WIPRO/BAJAJ/HAVELLS/CROMPTON
S&F LED street light lumanaries of size 100 W pressure die cast aluminium housing with heat resistance toughed glass & IP66 protection complete all as specified and directed Make- PHILLIPS/WIPRO/BAJAJ/HAVELLS/CROMPTON
S&F LED street light lumanaries of size 25 W pressure die cast aluminium housing with heat resistance toughed glass & IP66 protection complete all as specified and directed Make- PHILLIPS/WIPRO/BAJAJ/HAVELLS/CROMPTON
Supply & fix post of lantern fitting made out of black ABS plastic spigot & spun alluminium funnel shaped with clear acraylic cover suitable for 45 w led lamp fitting including lamp complete all as per cat no 112364 of make BAJAJ /wipro ca no-LP02-501-XXX-57-XX/ CROMPTON - LPTO-45/CDL to mount on gate all as per site requirement and complete all as specified and directed by Engr-in-Charge.
S&F in repairs PVC insulated 3 core 2.5 sqmm multistranded COPPER conductor for connection of Security light from JN BOX to Security light /OH conductor to security light all complete as specified and directed Make: finolex/plaza/havells/CCI/PARAGON
S&F in repairs PVC insulated 3 core 1.5 sqmm multistranded COPPER conductor for connection of Security light from JN BOX to Security light /OH conductor to security light all complete as specified and directed Make: finolex/plaza/havells/CCI/PARAGON
S&F in repairs Astrorex D-22, Multifunctional digital time swithces cat no 004767 of legrand or equivalent of L & T/GIC
S&F in repairs galvanized earth strip 32 mm x 6 mm for earthing from earth plate to equipment complete fixed on pocelain insulator every 1 meter interval all as specified and as directed.
S&F in repairs ALLUMINIUM earth strip 25 mm x 4 mm for earthing from earth plate to equipment complete fixed on pocelain insulator every 1 meter interval all as specified and as directed.
S&F in repairs COPPER earth strip 20 mm x 3 mm for earthing from earth plate to equipment complete fixed on pocelain insulator every 1 meter interval all as specified and as directed.
Suply & fix MCCB 250 A 35 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified Make : L&T cat no- CM92109OOP1OG /Legrand cat no-420249/schneider cat no-LV525343
Suply & fix MCCB 200 A 35 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified Make : L&T cat no- CM92109OON1OG /Legrand cat no-420248/schneider cat no-LV525342
Suply & fix MCCB 160 A 35 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified Make : L&T cat no- CM92109OOM1OG /Legrand cat no-420247/schneider cat no-LV516343
Suply & fix MCCB 125 A 25 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified Make : L&T cat no- CM92108OOL1OG /Legrand cat no-420056/schneider cat no-LV516312
Suply & fix MCCB 100 A 25 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified Make : L&T cat no- SL98605OOOO /Legrand cat no-420055/schneider cat no-LV510317
Suply & fix MCCB 63 A 25 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified Make : L&T cat no- SL98603OOOO /Legrand cat no-420013/schneider cat no-LV510315
Taking down MCCB any type & any size
M&L for Preparation for surface of existing PCC poles including cross arms, nuts, bolts, for painting LT pole 7.5 mtr long above ground level and applying one coat of approved quality Exterior grade apex paint all as directed by Engr in charge.
M&L for Preparation for surface of existing steel poles including cross arms, nuts, bolts, for painting LT pole 7.5 mtr long above ground level and applying one coat of approved quality of aluminum paint all as directed by Engr in charge.
Manning and operation for routine maintanence of water supply installation (pump house) with deputing one skilled FGM operator of proper trade with ITI qualified having minimum 4 years of experience for two shift of 08 hours each shift (Per day 16 hrs including holiday and sunday) for operation of pump sets, chloromes plant/Bleaching Dozer for proper pumping of lekhanagar including all valves, maintaining all eqpt of pump house, OH tanks, in perfect conditions cleaninf of all water supply installation and sorrounding area all specified and directed by Engr-in Charge. All the tools and safety equipment will be provided by the contractor as per precribed procedure. The installation comprises the following installations : (a) 4 Nos borewell (15 HP submersible including Starter, panels and connected items). (b) 04 Nos of Sluice Valves for pumping from borewells. (c) 04 Nos of Sluice valves supply from OH tank.
Manning and operation for routine electrical complaints by deputing one skilled Electrician and one helper (helper unskilled) operator of proper trade with ITI qualified having minimum 4 years of experience for of 08 hours each shift daily from 8.00 AM to 4 Pm including holiday and sunday) for complaints of lekhanagar residential colony. All complaints of nature of LT and internal electrification shall attained by the electrician and helper, All the tools and safety equipment will be provided by the contractor as per precribed procedure.
Manning and operation for routine water supply complaints by deputing one skilled Plumber of proper trade with ITI qualified having minimum 4 years of experience for of 08 hours each shift daily from 8.00 AM to 4 Pm including holiday and sunday) for complaints of lekhanagar residential colony. All complaints of nature of water supply shall attained by the Plumber, All the tools and safety equipment will be provided by the contractor as per precribed procedure.
It is the responsibility of AGE/JE to ensure that attendance register is maintained at all the installation duly signed kept on record and payment of trade men for the Nos of days present will only be made, Engineer-in-Charge will be responsible for payment of trade men in his presence. Contractor shall provide proper dress to tradesmen as approved by Eng-in-Charge and during duty hours all tradesmen shall be in proper uniform otherwise necessary recovery @ double the quoted rate for per shift shall be made from his dues.
Leave of deployed person in inescapable cases shall be allowed on prior intimation but Contractor on demand of Engineer-in-Charge, shall arrange alternate arrangment. Payment shall not be allowed for leave period. Recovery @ double the quoted rate shall be made for unauthorised absent
In no case wages of deployed persons shall be less than the Minimum wages fixed by Govt Competent Authority. It is mandatory requirement for Contractor that payment of deployed person shall be made through Cheque/RTGS/Acceptable Electronic Mode only. Proof of payment shall be submitted by Contractor to Engineer in Charge on monthly basis.
The Employees Provident Funds & Miscellaneous Provisions (EPF & MP) Act, 1952. shall be strictly adhered to by the Contractor. Social Security to workers i.e. EPF, ESIC, Personal Insurance(if applicable) on part of Employer shall be paid by Contractor and accordingly, Contractor/Bidder shall include all these factors in his quoted rate. The prevailing rate/wage/contribution shall be as applicable on the bid submission end date
Quotations with ' Nil' or 'Zero ' consideration (overhead and profit) shall be considered non bonafide and will be rejected in financial evaluation.
Any variation in minimum wage , liability of EPF/ESIC/Bonus/LWC/GST shall be adjusted for reimbursement/recovery as under :- (i) Variation in minimum wage including other related statutory provisions shall be adjusted in terms of Condition 63 of GCC (IAFW-2249). (ii) Variation in percentage/rate of GST and LWC shall be adjusted as per instructions in Annexure XVI of MES Manual on Contracts which deals with ' Reimbursement/Refund on Variation in Taxes Directly Related to Contract Value '. (iii) Rates shall be quoted only upto two digits after decimal If any rate quoted/derived by the contractor works out to more than two digits after decimal , then the same shall be rounded off upto two digits after decimal. The rounding off shall be done in accordance with Rules for Rounding off of Numerical Values in accordance with IS : 02 of 1960 (Revised 2016) of BIS
Statuatory levies/GST if applicable on part of contracts shall be paid by Contractor and accordingly, Contractor/Bidder shall include all these factors in his quoted rate.
Deployed person shall report daily to JE or Engineer in charge or nominated officers by Accepting Officer for their attendence & obtain instructions. An attendence register shall be maintained by Contractor on site shall be certified by MES rep every day.
T&P - Working Tools/plants, protective cloths, communication & conveyance arrangments shall be provided by Contractor at his own cost.
An uniform of blue shirt/jersy duly embossed "MES OUTSOURCING SERVICES" at back and name plate of the person on front left shall be provided by contractor to all workers at his own cost.
Documentation - Attendance register & wages register,Daily work register as per the format provided by the Deptt. shall be prepared & maintained at his own cost.
Contractor shall be made security pass for all operators and maintain proper register duly signed by all concerned
Supply and installation of fountain header circular 4.5 mtr dia made of “Medium grade”,50mm dia steel pipe and one one number 25mm dia branch for jet at the centre of fountain , bent to shape including drilling and welding 20 Nos 15mm dia GI sockets for fixing of jet nozzles and connecting to incoming 50 mm dia water pipe line from pump set using flange jointing and painting of header using two coats of anti corrosive paint over a coat of primer incl dismantling the old existing fountain complete all as specified and directed. Note :- (i) Scope of work shall including all mounting arrangement of header over masonary pedestals of fountain pond. (ii) The jet nozzles and nozzle valves of header shall be measured and paid separately.
M & L for drilling and taping cast iron water mains (in position) for branch connections of internal dia 20mm including saddle piece and nuts and bolts as required at site all as specified and directed.
Supply, Install ,testing and commissioning of open well submersible pump Horizontal monoblock type of head 26 mtr head , discharge capacity 13.6 LPS , power rating 5 HP, 50 Hz , 440 volts , 2920 RPM Cast Iron impeller,stainless steel shaft pump model KOS 830+ of Kirloskar or equivalant of KSB/Crompton all as directed.
Supply and Fixing of pump panel board outdoor type made of 3mm thick CRCA sheet, front opening type complete with weither proof gasket and locking arrangement suitable for housing of pump starter including supply and fixing autometic star delta submersible pump Starter with single phase priventer and all accessories confirming to (Cat No : IHDASALBW) of Havells make orequivalant of L&T/CG , to be fixed on 50x50x6mm thick angle iron stand 45cm above GL including 30cm PCC foundation in CM 1:3:6 type C2 below GL and making electric connection all as directed.
Supply and fixing PVC insulated and PVC sheathed submersible cable with plain copper conductor having three core flat for submersible motors of size 4 Sqmm (56/0.3) all as specified and directed.
Material and labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm 4 core all as specified and directed. Make: Finolex/Havells/Gloster
Supply and fixing PVC insulated and PVC sheathed submersible cable with plain copper conductor having three core flat for submersible motors of size 1.5 Sqmm (36/0.3) all as specified and directed. Make: Finolex/Havells/Gloster
Supply and fixing under water LED 18W (9x2W) ,12 volts, RGB multi colour stainless steel (SS 304 in electropolish) light fitting with 5 mm clear toughned glass wall recessed mounting IP 68 protection class complete all as specified and directed Make- PHILLIPS/WIPRO/BAJAJ/HAVELLS/CROMPTON
Supply and fixing of jet nozzle bronze natural finish,smallest orifice start from 0.085 mm,PF-1101, jet orifice -15 mm, 3 meter spray height complete all as specified and directed by Engr-in-Charge.
The rate quoted for items of outsourcing shall not be less than minimum wages as notified by Government of India/concerned State Government/Local Body, whichever is higher and also not less than applicable rates for contribution of employer towards EPF, contribution to ESIC, contribution of Bonus and LWC under respective headings/sub-items In case the rates quoted are less than the prevailing rates/instructions under any heading(s) , the bid will be treated as non bonafide/invalid, shall be disqualified and such bids will not be considered for acceptance . In such case, the lowest bidder shall be determined from amongst the valid/bonafide bids only
Schedule of credit amount of Rs. 1,50,277.00 to be deducted during AOC
RAVINDRA ELECTRICAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .