Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L2₹5.4 LAccepted-Finance | L2 | Accepted-Finance TECHNICALLY AND FINANCIALLY QUALIFIED | |
| 2 | L2₹5.8 LAccepted-Finance | L2 | Accepted-Finance TECHNICALLY AND FINANCIALLY QUALIFIED | |
| 3 | L3₹6.3 LAccepted-Finance | L3 | Accepted-Finance TECHNICALLY AND FINANCIALLY QUALIFIED | |
| 4 | L4₹6.6 LAccepted-Finance | L4 | Accepted-Finance TECHNICALLY AND FINANCIALLY QUALIFIED |
Tender Value
₹5.9 L
EMD Value
₹11,760
Closing Date
8 Jul 2022, 1:00 pmClosed
OFFICE OF EX. ENGINEER KPDCL DIV.SHOPIAN
OFFICE OF EX. ENGINEER KPDCL DIV.SHOPIAN NEAR DEGREE COLLEGE SHOPIAN
CREATION OF 25 KVA SuB STN alongwith HTLT NW at Shirmal for Providing of Power Supply to Cafeteria located near Mega Fruit Mandi Aglar by way Providing AND installation of Transformer along with all Accessories for Assets created at Shirmal ShOPIAN
2022_PDD_175998_1
EDS/ETENDER/16 OF 2022-23 DATED.24-06-2022
Open Tender
Electrical and Maintenance Works
Turn-key
20 days
UNDER JURISDICTION OF DIV.SHOPIAN IN SD KELLER
PLEASE REFER TO THE TENDER DOCUMENT
8 documents required · 8 mandatory
₹400
EXECUTIVE ENGINEER KPDCL DIVISION SHOPIAN
₹11,760
Yes
12 Jul 2022
24 Jun 2022
9 Jul 2022
24 Jun 2022
8 Jul 2022
25 Jun 2022
25 Jun 2022 - 25 Jun 2022
Amount
Supply, installation, Testing and Commissioning of 11/0.433 kV, 3-phase 25 KVA Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Al wound ), and with LV Cable Box having detachable Aluminium Gland plate
Supply, Errection, testing & commissioning of ST poles 9 mtr long 410-SP-33 164 Kgs with base plate and cap including transportation as per REC Standard
Supply, Errection, testing & commissioning of ST poles 8 mtr long 410-SP-15 119Kgs with base plate and cap including transportation as per REC Standard
Supply, Transportation, Laying, stringing and binding of conductor including joints with PG clamps of required size 30 mm2 ACSR ( Weasel)
Supply, installation, Testing and Commissioning of 35 mm² AB (HT) Cable (3x35+1x70 mm²) XLPE(11 kV, 3C + Earth)
Supply,Fixing of Heat Shrinkable Outdoor Cable Termination Kit ( 3 core)
Supply and laying of Cement bottoming 1:2:4 mix as per REC standards 0.45 cum/pole, muffing 20 cm above ground level ,including plaster and curing of concrete in size of 600x600x1700 mm for ST Poles for refilling the pit (the leftover pit after concreting to be filled with soil and boulders) NOTE: Please refer Pole drawings for details
Supplying and erection of GI channel (75x40x6 mm) , GI Angle( 50x50x6 mm), 50X50X6 mm angle support including clamps for Sub-Station Frame as per REC approved Drawings.
Supplying and erection of GI Channel “V’ cross-arm (75 x 40x6mm) with GI Angle Pole Top Bracket (50x50x6 mm) including back clamps of 50X8 mm for fixing V-Cross arm and pole top bracket without making holes in the ST pole as per REC standard for single pole structure. NOTE: Please refer Pole drawings for details
Providing and Fixing of 11 KV pin insulator Complete (Polymer/Porcelain) 5 KN With Pins
Supply and fixing of LT Distribution Box for 25 KVA DTR with TPN MCCBs short ckt rating 16 KA for incomer 40 Amp ( 25 KVA) and suitable MCCBs for outgoing circuits with terminal extensions.
Supply and Installation of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
Supply and Installation of 11KV D.O FUSE SET 3 Phase 400 Ampere Horn Gap
Supply and Installation of 11 KV LA SET 9 KVA ,10 KA,LA WITH Polymer ,Porcelain Housing Station Type
Supply and Installation of 70 mm² (2Ckt) Single Phase Cable,1.1K V Grade, PVC Insulated Stranded Conductor FRLS type
Providing and Fixing of Alumunium Thimbles of sizes
Providing and Fixing of SL CLAMP (25 KVA)
Providing and Fixing of Nut & Bolts GI
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Painting of each Pole 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint)
Supply and Installation of Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Supplying and erection of Danger Plates with clamps with writing in English and Regional Language
Supply and Installation of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete (11 kV)
Supply and fixing of anti-climbing GI Barbed wire binding with Clamps at a distance of 30 to 40 cm at a height of 3.5 to 4 m from ground level. At-least 2 kgs GI barbed wire(12 SWG) is to be used per pole for the purpose.
Providing and Fixing of LT Shackle Insulators with Muki clamps GI Flat iron (50*6)mm
Supplying and fixing of Suspension/Tension clamps with eye hooks
Supplying and fixing of 25 Sq. mm 2 Core aromured Service Cable
Supply and Installation of LT Prodigy Meter
Identification of assets by marking of Transformer with white paint & marking of poles with Black paint at a height of 2.40 mtr from ground level. (Note : Mention Name of Scheme , Implementing Agency (JKPDD), Year of Implementing (2022-23)
Geo Tagged Photographs of high resolution (Pre and Post Photographs) Both hard and soft copy (for e-compendium) 4 Photographs Per site
Reaching Rays Infra Electricals
Global Engineering Services
southern
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .