Loading…
Loading…
Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical 84B AKHIL MISTRY LANE AMHERST STREET AMHERST STREET KOLKATA WEST BENGAL 700009 | KOLKATA | WEST BENGAL | 700009 | Accepted-Technical BID Documents found in order |
Tender Value
Refer Docs
EMD Value
₹11,532
Closing Date
25 May 2026, 1:00 pmClosed
Executive Engineer(E), Sambalpur
O/o the Executive Engineer(E), 1st Floor, BSNL DSB, Kachery Road, Sambalpur 768001
Attending day to day faults, Repairing and Maintenance of Split A/C and WAC at various Telephone Exchanges and mobile BTS sites of Sambalpur BA for the year 2026-27 (For Sambalpur OA)
2026_BSNL_277751_1
07/EE(E)/BSNL/ED/SBP/2026-27
Open Tender
Electrical Works
Item Rate
365 days
Sambalpur SSA
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
A.O.(Cash), BSNL, O/o the GMTD, Sambalpur
₹11,532
Yes
27 May 2026
16 May 2026
26 May 2026
16 May 2026
25 May 2026
16 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Attending site on call basis for repairs of Split/Window AC in Telephone Exchange by 1 no skilled and 1no unskilled technician as per distance mentioned below with necessary T& P etc as required. Note :(1) The visit will be made as per instruction of the Engineer-in-charge (2) If any site attended only 1 visit may be considered for payments till rectification of faults (a) In Sambalpur and within 50Km distance from SSA H/Q | 50 | Jobs | -1 | - |
| 1.1 | b) In other areas exceedingh 50Kms | 30 | Jobs | - | - |
| 2 | General Servicing of 1.5 /2.0 TR WAC/SAC units of different make I/c removing from existing position( for WAC ) cleaning the air filter, cleaning the condenser and evaporator coil with help of Blower and cleaning with cleaning solution ,finally cleaning with water etc complete as reqd. | 60 | Jobs | 1 | ₹60 |
| 3 | Replacement of the following capacity Rotary type compressor I/c dismantling of the old compressor and I/T/C of new compressor in existing WAC / Split AC etc complete as required ( a) 1.5TR Compressor Note:-The new compressor should carry a warranty of one year) | 2 | Jobs | 2 | ₹4 |
| 4 | Charging of Refrigerant gas R-22/R -407 /R -410 up to specified pressure in following capacity AC units ,leak testing , leak rectification and testing commissioning of the AC unit etc. as reqd. ( a)1.5 TR WAC/ Split AC | 8 | jobs | 3 | ₹24 |
| 5 | Top up of R-22 / R-407 /R -410 gas in existing Window A.C /Split A.C units, i/c testing etc. as required. | 10 | Kg | 4 | ₹40 |
| 6 | Replacement of the following items/accessories in the existing AC Units in place of faulty/unserviceable parts i/c dismantling of the faulty, fixing the new item and commisioning , testing etc. complete as reqd.( a) Starting Capacitor ( 80-100/120 mfd) | 10 | Each | 5 | ₹50 |
| 6.01 | b) Running Capacitor ( 36 / 40 mfd ) | 20 | Each | 6 | ₹120 |
| 6.02 | c) Relay for WAC / Split AC | 20 | Each | 7 | ₹140 |
| 6.03 | d) Fan Motor Capacitor 4/6 mfd) | 20 | Each | 8 | ₹160 |
stage.html
html • 0.02 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.22 MB
BOQ_324341.xls
BOQ • 2.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .