| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.4 LAccepted-AOC FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹24.9 L+₹54,059 (2.22%)Rejected-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹25.0 L+₹65,551 (2.69%)Rejected-AOC 1001 B BHAVESHWAR BLDG NO 03 BHAVESHWAR LANE GHATKOPAR EAST MUMBAI 400077 | MUMBAI SUBURBAN | MAHARASHTRA | 400077 | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹26.9 L+₹2.5 L (10.4%)Rejected-AOC | L4 | Rejected-AOC NOT LOWEST | |
| 5 | L5₹27.3 L+₹3.0 L (12.3%)Rejected-AOC FLAT NO 703 7TH FLOOR PARVATI ENCLAVE PLOT NO 180 SECTOR 2 TOLOJA PANCHANANDTAL TALOJA MAJKUR DISTT RAIGAD MAHARASHTRA 410208 | RAIGAD | MAHARASHTRA | 410208 | L5 | Rejected-AOC NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
24 Nov 2020, 6:00 pmClosed
GE (NW) MANKHURD
GE (NW) MANKHURD MUMBAI 400088
REPAIR MAINTENANCE OF INTERNAL ELECTRIFICATION INCLUDING FITTINGS AND FIXTURES AT DOMESTIC AREA AND REPAIR/ MAINTENANCE OF SECURITY LIGHTS, UG CABLES POST TOP LANTERN AND GARDEN LIGHTS TECHNICAL AREA UNDER GE (NW) MANKHURD
2020_MES_390335_1
8018/E8
Open Tender
Civil Works
Item Rate
330 days
GE (NW) MANKHURD
AS PER NIT AND TENDER PAGES
9 documents required · 9 mandatory
₹500
GE (NW) MANKHURD
₹70,000
Yes
2 Dec 2020
27 Oct 2020
26 Nov 2020
27 Oct 2020
24 Nov 2020
12 Nov 2020
27 Oct 2020 - 11 Nov 2020
Amount
Notes : (i)The contractor should be in possession of valid electrical license to execute electrical works. (ii) Supervisor for execution of electrical works/ electrical component of works employed by the contractor shall possesses supervisor certificate of competency issued by concerned State Government/ Union Territory and the worker/ tradesmen for execution of electrical works/ electrical component of works shall hold necessary permit issued by concerned State Government/ Union Territory. Taking down copper/ aluminum point wiring surface type, concealed type, flame proof type (Light/Fan/Socket or power) complete including fixtures and fittings such as switches, ceiling roses, pendants, regulators, socket, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces to walls floors etc complete all as specified and directed.
Taking down of Old MCB DB of any size complete all as specified and directed.
M & L for point wiring with PVC insulated unsheathed 1100 Volts grade single core FRLS multistranded copper conductor cable 1.5 Sqmm drawn in and including PVC casing-caping and accessories, fixed on wall / ceiling etc with neccessary fixing accessories and earth continuity FRLS multistranded copper conductor cable of 1.5 sqmm size connected to common earth and earth dolly including 2 mm thick pressed steel terminal boxes concealed in wall covered with laminated sheet top cover 3 mm thick for mounting switches / sockets / fan regulators fixed with Cadmium plated machine screws all as specified for "One light / fan / bell point controlled by one switch".
All as per item No 3.00 above but for One 5A 2pin/3pin socket out let multipurpose on the same board with other switches complete all as specified and directed.
All as per item No 3.00 above but for One 5A 2pin/3pin switch socket out let multipurpose on independent Board complete all as specified and directed.
All as per item No. 03 above but wiring with 2.5 Sqmm for 3 pin 15A socket multipurpose on independent board complete all as specified and directed.
Supply & Fix switch piano single pole flush type 5A, 240 V one way complete all as specified and directed.
Supply & Fix Bell push flush type 5 amp, 250 Volts complete all as specified and directed.
Supply & Fix switch socket combination 2 in 1 , 5 Amps multipurpose flush type complete all as specified and directed.
Supply & Fix switch socket combination 2 in 1, 3 pin, 5 and 15 Amps flush type universal complete all as specified and directed.
Supply & Fix Ceiling rose surface bakelite three terminal, 240 V complete all as specified and directed.
Supply & Fix electronic regulator Step type 2 module type 240V suitable for ceiling fan complete all as specified and directed.
Supply and fix bell ding dong AC 230 V single pole complete all as specified and directed.
S&F in Repairs/Replacement Ultra bright glass LED tube rod 20 Watts, 230 volts with very high efficiency with G13 lamp holder including fixing arrangements complete all as specified and directed. Make : Havells Cat No. CRYSTAL 1213T8DSTL20WLED865SGLASS / Crompton/Wipro/Bajaj
S&F in Repairs/Replacement Surface and wall mounted batten suitable for LED tube 22 watts, 230 volts, including fixing mounting blocks 2 Nos, 1.5 sqmm 3 core Pvc insulated copper conductor cable including fixing arrangements complete all as specified and directed. Note : The fitting shall conform to Cat No. REGALBATTENT8UPTO1X22WDSBSWH of Havells/Crompton/Wipro/Bajaj
S&F surface and wall mounted 10 Watt LED batten with LED rod complete, extruded aluminium housig provided for efficient heat dissipation with polycarbonate diffuser & interrated electronic driver including fixing arrangements complete all as specified and directed. Note : The Fitting Shall conform to Cat no - ENDURALINEARNEOBS10WLED830SPCWH of Havells/Crompton/Wipro/Bajaj
Supply & fix in repairs new generation, ultra modern recess mounting luminaire 36 Watt (Pluto Neo Panel 4x1) with high brightness SMD LED as light source and including driver unit, and provision of 3 core copper flexible cable size 1.5 Sqmm from ceiling rose to connector, including making addition/altn to existing false ceiling and providing of false ceiling sheets, aluminium frames including fixing arrangements etc complete all as specified and directed. Note : The Fitting Shall Conform to Cat No -PLUTONEO4X1PLR36WLED840S of Havells /Crompton/Wipro/Bajaj
Supply and fix in repairs decorative recessed type LED light fitting 36 watt (size 2'x2') and including driver unit and provision of 3 core copper flexible cable of 1.5 sqmm from ceiling rose to connector, including making addition/altn to existing false ceiling and providing of false ceiling sheets, aluminium frames including fixing arrangements etc complete all as specified and directed. Note : The Fitting Shall Conform to Cat No -ENDURASLIMPROPLUS2X2PR28/36WLED840MOD for Module and LEDDRIVER36V28WS for driver of Havells/Crompton/Wipro/Bajaj
Taking Down Ceiling fans of size 1200 mm sweep and refixing the same after replacing the 3 Core 1.5 sqmm wire from ceiling rose to fan and including painting of ceiling fan and painting of MES No etc complete all as specified and directed.
Supply And Fix in repairs MCCB DB TPN 4 Way double door 125 Amps prewired suitable for Triple Pole 125 A MCCB as incomer with the following acessories etc complete all as specified and directed. a) MCCB TP 125 A 25 KA 415 Volt - 1 Nos b) Bus bar, Din rail , Neutral link
Supply And Fix in repairs MCCB DB TPN 8 Way double door 125 Amps prewired suitable for Triple Pole 125 A MCCB as incomer with the following acessories & connecting of existing cables & providing of cable glands etc complete all as specified and directed. a) MCCB TP 125 A 25 KA 415 Volt - 1 No b) Bus bar, Din rail , Neutral link
Supply & Fix MCB DB SPN 2 way 240 volts Single door, including connecting up with existing cable with new lugs complete all as specified and directed.
Supply & Fix MCB DB SPN 4 way 240 volts double door including connecting up with existing cable with new lugs complete all as specified and directed.
Supply & Fix MCB DB Double Door SPN 8 way 240 volts including connecting up with existing cable with new lugs complete all as specified and directed.
Supply & Fix MCB DB Double Door SPN 12 way 240 volts including connecting up with existing cable with new lugs complete all as specified and directed.
Supply & Fix MCB DB TPN 4 way 415 V double door with busbar including connecting up with existing cable with new lugs complete all as specified and directed.
M&L for MCB SP, 240 volt, 6 to 32 Amps, 10 KA, C Curve complete all as specified and directed.
M&L for MCB SPN, 240 volt, 6 to 40 Amps, 10 KA, C Curve complete all as specified and directed.
M&L for MCB TPN, 240 volt, 63 Amps, 10 KA, C Curve complete all as specified and directed.
Supply & lay XLPE insulated two core 4.0 Sqmm PVC insulated FRLS multistranded flexible multi stranded copper conductor armoured cable 660/1100 volts grade including saddles & spacers for clamping the cables along the wall etc complete all as specified and directed.
M&L for earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the earth plate not less than 1.5M below normal GL, connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 15 mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I, 2009 specification etc complete all as specified and directed.
M&L for sub main wiring with two single core 1.5 Sqmm PVC insulated FRLS multistranded copper conductor cable 660/1100 volts grade drawn in through non metalic PVC casing caping with and including PVC insulated 1.5 Sqmm single core multistranded copper conductor FRLS as continous earth wire in green colour connected to common earth dolly all as specified and as directed Note : Two runs of cable, one run of earth wire, one run of PVC casing capping will be measured and paid one unit.
S&F in repair/replacement of building Security light fitting 30 Watt made up of pressure die cast alluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07 including fixing arrangements and taking down old rusted bracket fittings complete all as specified and directed. Note : The fitting shall conform to Cat no ENDURAPEARLSL30WLED757SASYTOPCMP of Havells/ Crompton/Wipro/Bajaj
M& L in repairs/replacement of bracket made out of GI pipe 40mm dia medium grade, 1.2mtr long bent to shape with MS flat iron clamps made out of 40mmX 6mm thick FI nuts, bolts complete all as specified and directed.
Taking down old unserviceable security light fittings and Garden lights fitting from the street light poles/walls/Garden pole for repairs and replacement of burnt/worn out accessories and refixing the same in existing position including testing after repair complete all as specified and directed. Note :- (i) Minor Spares such as insulation tape, Lamp Holder, Connectors, Screws, nuts, bolts, washers, T & P, Ladder etc are deemed to be included in the quoted rate. (iii) The representative of the contrcator shall report to Engineer-in-charge/JE and carry out repairs on daily basis during the contract period
Supply and fixing in repairs Electronic Meter 10-60 amps Single phase tamper proof with Class 1 accuracy Optical port,LED Indication for earth leakage ,Elegant Polycarbonate Enclosure,High Surge withstand upto 8 KV,anti tamper features,Electromagnetic compatible & 6 digit Display Make L&T Model No.EM101 Cat No. WM101BC7DDH or equivalent make as specified in PS.
M&L for testing of old earthing using calibrated earth tester & submitting result to engr -in -charge complete all as specified and directed. Note : Watering of earthing with 2 Buckets (30Ltrs) water mixed with salt (total 20Kg) shall be carried out one day before the testing & the cost of the same shall deemed to be included in unit rate quoted.
M&L for painting on wall with synthetic enameled paint of black colour of 200 x 150 mm size and writing work for earth test result with date & year complete all as specified and directed.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth and getting out in in any type of soil complete all as specified and directed. Note - Cable Cover Found serviceable shall be kept in safe custody and shall be relayed under respective item.
Returning filling in , excavated soil including spreading, leveling and well ramming in layers not exc 25cms each any type of soil complete all as specified and directed.
Removing the excavated materials not exc 50mtr and depositing where directed at a level not exceeding 1.5 mtr above the staring point complete all as specified and directed.
M&L for sand cushioning by spreading in trenches fine dry river sand by gently by punning down manually as in cable protection complete all as specified and directed.
Supply and laying precast concrete cable cover class LV ISI Marked, type-I, flat size 250mm x 150mm x 40mm laid in trenches complete all as specified and directed.
Laying only precast concrete cable cover class LV type in trenches complete all as specified and directed.
Supply & Lay PVC insulated, heavy duty 1100 volt grade electric LT UG cable with aluminium conductor of size 10 Sqmm 4 Core in trenches/along the wall/including taking down old unsv cable and making all connections complete with lugs as required at site complete all as specified and directed.
Supply & Lay PVC insulated, heavy duty 1100 volt grade electric LT UG cable with aluminium conductor of size 35 Sqmm 3.5 Core in trenches/along the wall/including taking down old unsv cable making all connections complete with lugs as required at site etc complete all as specified and directed.
M&L for cutting existing road/hard standing not exc 45x45 cm in wide & depth getting out excavated material for laying GI tube ;returning filling & well rammaing watering finish surface 10 cm from top using PCC 1:3:6; including removal of surplus soil etc complete all as specified and directed.
S& F in replacement of GI steel tubing light grade 40 mm dia for laying in ground, along the pole in coping, road crossing etc for cable protection including necessary fittings , clamps for supports, etc complete all as specified and directed.
Supply and fix in repair of Cable junction box IP 66/69 "weather proof" (with knockouts for cable entry) box of size 155 x 210 x 92 mm with connector/terminal, Din Rail, GI clamps made out of GI flat of size 25 mm X 3 mm channel including providing detachable GI 3 mm thick plate inside looping box as cable gland plate and including cable glands as required at size and making connections complete all as specified and directed. Make - Hensel cat part No KF1616B /National/Sintax
Supply and fix in repair of Cable junction box IP 66/69 "weather proof" (with knockouts for cable entry) box of size 130 x 180 x 77 mm with connector/terminal, Din Rail, GI clamps made out of GI flat of size 25 mm X 3 mm channel including providing detachable GI 3 mm thick plate inside looping box as cable gland plate and including cable glands as required at size and making connections complete all as specified and directed. Make - Hensel cat part No KF1010B /National/Sintax
M&L for taking down old unsv and supply & lay 3 Core 1.5 Sq mm size multistranded copper conductor PVC unsheathed 650 / 1100 Volt Grade As per IS 694 with and including 20 mm dia PVC conduit and passing through PVC conduit with necessary saddle, clamps, bolts & nuts, all for interconnection of cable looping box to Street Light Fitting, Post Top Lantern etc complete all as specified and directed.
M&L in repair/replacement of Multistranded Copper Conductor cable of 3 Core 1.5 Sq mm size drawn through steel tubular poles for interconnection of cable looping box to Street Light Fitting, Post Top Lantern etc complete all as specified and directed.
M&L in repairs for 24 Hrs 240 V FM1 Quartz type daily timer for controlling street lights contactors complete all as specified and directed. Make : Cat No J648B1-1 of L&T or equivalent make as specified in PS.
S & F in repair/replacement of LED Driver upto 70 Watts Suitable for street light fitting, driver Shall Conform to Cat no X075C070V107FNY1BO of Crompton or Equivalent from Philips/Bajaj complete all as specified and directed.
S & F in repair/replacement of LED Driver up to 40 Watts Suitable for street light fitting, driver Shall Conform to Cat No S0DQL1-54-700-40Wof Crompton or Equivalent from Philips/Bajaj complete all as specified and directed.
To depute service representative to attend the LED Solar Light fittings of 18 wattage once in a month . Service Representative will Carry scheduled preventative maintenance checks as per details given below at Mankhurd for 26 fittings per month :- (a) Solar PV Modules - Check the Circuit Voltage and current characteristics. Also, check the mechanical integrity of the Solar PV Modules. (b) Battery Bank -Check the Specific Gravity of the Electrolyte, Electrolyte level, battery terminals, Battery Bank box and adding Electrolyte solution if required. Note : Electrolyte solution will be measured seprately under this Schedule. (c) Solar PCU - Check DC input Voltage and Current, Check AC input Voltage and Current, checking the wiring. (d) Module Mounting Structures -Check the mechanical integrity of the Solar PV Modules Mounting Structures. Ensure that there is no corrosion set up on the MMS and the module is firmly fixed. (e) System Wiring - Check the system wiring including the insulations, cable lugs and rewiring/soldering if any required (f) Module Cleanliness - Cleaning of the dust accumulated over the Solar Module, and taking corrective measures
M&L for preparation of old painted surfaces of Solar Street Light Poles including acessories by scarping old paint and applying two coats of aluminium paint including numbering of pole with black oil paint etc complete all as specified and directed.
Supply and fix in replacement of LED 18 watt DC solar light fitting etc complete all as specified and directed. Make - Emvee / ICPC Solar
Supply and fix in replacement of low maintenance VRLA lead acidic battery of 120 AH suitable for 1 x 18 watt Soalr Light fitting all as per recommanded by Manufracturer complete all as specified and directed.
Supply and fix in replacement of charge controller suitable for 18 watt Solar Light fittings including any wiring as required complete all as specified and directed.
Supply only electrolyte solution to be incorporated in servicing, suitable for Solar charged battery of any capacity complete all as specified and directed.
Supply and fix in replacement street light fittings in street light poles/Buildings the fitting shall be of LED type 60 Watts complete with and including drivers, pressure die cast aluminium housing, prewired complete all as specified and directed. Note : The fitting shalll conform to cat No -ENDURAPEARLPLUSSL60WLED757SASYTOPC of Havells/Crompton /Wipro/Bajaj
Supply and fix in replacement flood light fittings in street light poles/Buildings the fitting shall be of LED type 150 Watts complete with and including drivers, pressure die cast aluminium housing, prewired complete all as specified and directed. Note : The fitting shalll conform to cat No . ENDURAPULSENSL150WLED757PASYBOTG of Havells/Crompton /Wipro/Bajaj
Supply and fix in replacement LED Down light fittings in security post sheds the fitting shall be of LED type 18 Watts complete with and including drivers, prewired complete all as specified and directed. Note : The fitting shalll conform to cat No - LSDE-18-CDL of Crompton or Equivalent from Philips/Bajaj/Havells
Supply & Fix 8 watts LED Bollard Garden light fittings with efficient high output LED, Pressure die cast powder coated housing with PCdiffuser , driver nuts, bolt, washers, base plate, foundation 0.3 Meter x 0.3 Meter x 0.3Meter by PCC 1:2:4 type B-1 using 20 mm graded stone aggregates of size including excavation and earthwork, provision of GI bend of size 50 mm dia in the PCC for cable entry etc complete all as specified and directed. Note : The Fitting Shall Conform to Cat No - CONEBL8WLED857SSYMTOPC of Havells or Equivalent from Bajaj/Crompton/Wipro
S & F decorative 35 Watts LED Post Top Lantern, 230 Volts, including drivers, pressure di cast aluminium housing, prewired complete all as specified and directed. Note : The fitting shalll conform to cat No - CORALPT35WLED757PSYMTOPC of Havells or Equivalent from Wipro/Bajaj/Crompton
S & F decorative 20 Watts LED Post Top Lantern, 230 Volts, including drivers, pressure di cast aluminium housing, prewired complete all as specified and directed. Note 1: The fitting shalll conform to cat No - RUBYT25WLED757PSYMTOPC of Havells or Equivalent from Crompton/Bajaj/Wipro Note 2: A sum of Rs 93,207.00 towards sch of credit shall be deducated to arrive the contract sum.
Shree Ayyappa Engineering
EVEREST POWER CONTROL ENGINEERS
Radha Engineering Services
DWARKESH STRUCT-CON
AGRAWAL ASSOCIATES
sapana enterprises
M/s Hari Om Construction
A P ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .