| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.8 LAccepted-AOC 292 GROUND FLOOR D BLOCK SAI DHAM RAJ CITY LONI BANTHLA GHAZIABAD GHAZIABAD UTTAR PRADESH 201102 | GHAZIABAD | UTTAR PRADESH | 201102 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹34.1 L+₹3.3 L (10.7%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹35.9 L+₹5.1 L (16.4%)Rejected-Finance 3RD FLOOR VVIP RESIDENCY MAHINDER VIHAR CHAKRATA RD NEAR RAMADA HOTEL DEHRADUN UTTARAKHAND 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹43.8 L+₹13.0 L (42.0%)Rejected-Finance | L4 | Rejected-Finance Not Lowest |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
13 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NORTH PUNE
Garrison Engineer North General Cariappa Marg Camp Pune 411001
GE (N) P/TOKEN- 70 OF 2022-2023 CLEANING OF OH RESERVOIRS, UG SUMPS AT VARIOUS INSTALLATIONS, PUMP HOUSES, SERVICE TANKS TO ACCNS AND OTHER ALLIED WORKS IN THE AREA OF AGE E/M (NORTH) UNDER GARRISON ENGINEER (NORTH) PUNE
2023_MES_573001_2
GE (N) P/TOKEN- 70 OF 2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
GE NORTH PUNE
Refer tender documents.
8 documents required · 8 mandatory
₹500
GE NORTH PUNE
₹88,000
Yes
17 Mar 2023
24 Jan 2023
20 Feb 2023
24 Jan 2023
13 Feb 2023
31 Jan 2023
25 Jan 2023 - 27 Jan 2023
Amount
Material and labour for cleaning of RCC underground Sump after scrapping out the scales/deposits from all inner surfaces of sump thoroughly washing with bleaching powder solution (mixed @ 0.5 Kg of bleaching powder of chlorine content 30% per 1000 liters of water), bailing out the settled materials completely away from the site within 100 metres distance, cleaning the tank through seven stage process and refilling with clean water and finally sterilizing the tank as mentioned in notes below and resetting the existing level readings complete including taking down and re-fixing of foot valve after necessary cleaning, repairs etc., and replacing minor parts if any required for proper functioning of foot valve, testing and writing “TANK CLEANED ON…..”(date), “DUE DATE ON…..(date) and "CAPACITY .... GALLONS" with 10 cm size white letters on black back ground by engaging skilled artist using best quality synthetic enamel paint all as specified and directed by Engr-in-Charge for the following sizes:- Note :- (a) Suitably blocking the incomming and outgoing wash out pipes for avoiding mud and foreign meterials deposited in the UG reservoirs getting into pipes and chocking it prior to starting the cleaning. (b) First stage is to drain out the water by using exit valve or high capacity dewatering system as provided by contractor without any extra cost to the Govt. before cleaning the mud and other deposits. (c) Filling up the over head reseviors full and feed the affected residential/OTM consumers enough water to sustain during the resevior cleaning period. (d) Second stage is cleaning all the algae formation inside the tank by using TERBAC G5 a laboratory tested branded chemical or as approved By Engnr - in charge complete all as directed.
(e) Third stage is scrubbing the walls with mechanized scrubber & fresh water cleaning by high speed jet pump. (f) Fourth stage and first bacteria screening is Sterilization by using TERBAC-G5 a Govt Laboratory certified branded halogen compound or as approved By Engnr - in charge complete all as directed. (g) Fifth stage is cleaning the floor of the water tank by industrial vacuum cleaner.(h) Sixth stage is the second bacteria screening and sterilizing method by using ultra violet ray with in the tank and kills all suspended bacteria (i) Seventh Stage of cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified branded strong oxidizing agent TERBAC- G65 or as approved By Engnr - in charge complete all as directed. (j) Fresh air to be blown into the tank for a period before allowing a person to enter. The cleaner should wear protective clothing, including gloves, a boots, Safety Helmet and glasses. Contractor should make sure someone remains outside the tank, next to the access hatch all the time in case the cleaner has an accident. The availability of gas masks and portable ventilators would be made available by the contractor at site during cleaning operation. (k) Remove the blockage from inlet/ outlet over flow pipes and ensure satisfactory distribution. (L) Writing of the date of cleaning of the water tank with white letters on black background. (m) All the required Tools and plants, lubricants/oils and materials will be supplied by the contractor during the work. Makes of service provider:Rays Cleantech Kolkata,Inus watertech Dist.24 Parganas North,Satya Enterprises Kolkata
Semi Under Ground sump of capacity 1,50,000.00 gallons at Ghorpadi Pump House No.1
Semi Under Ground sumpof 50,000 glns capacity at 64 Pump House, Victoria Road Pump House, Ghorpadi Pump House No 2, DAD Complex Pump House, Children School Pump House, Milkha Singh Pump House, Manoj Pandey Pump House, Old KG line New Pump House,Station Family Camp
Semi Under Ground sump of 40,000 gallons capacity at 64 Pump House and Victoria Road Pump House
Semi Under Ground sump of 30,000 gallons capacity at 16 Queens Garden Pump House, HQSC Pump House, Shanti Vihar Pump House, Ashoka marg Pump House.
Semi Under Ground sump of 25,000 gallons capacity at 64 Pump House and SCSR comminication complex Pump House.
Semi Under Ground sump of 20,000 gallons capacity at Test audit colony , Victoria Pump House, CESC Pump House, Nirman Vihar Pump House, MES Key personnel Pump House, Commnd MT Pump House, SCOM Pump House and Sainik Aramgrah pump House.
Semi Under Ground sump of 10,000 gallons capacity at CEPZ Pump House, Ashoka Marg Swimming pool , 6 queens garden
Semi Under Ground sump of 5,000 gallons capacity at PCDA office Pump House,NCC officers mess,Race course
Scrapping down, cleaning internal surfaces of walls, floors, roofs, drainage system etc of RCC OH reservoirs with of 10 to 20 metres hight staging, removing the accumulated sand/ silt from the chambers as described below and depositing where directed at a distance not exc 50 metres complete all as specified and as directed by the Engineer-in-Charge for the OH reservoir of capacity 60,000 gallons at Milka Singh Pump House and Old KG line Pump House :- (a) Suitably blocking the incomming and outgoing wash out pipes for avoiding mud and foreign meterials deposited in the OH reservoirs getting into pipes and chocking it prior to starting the cleaning. (b) First stage is to drain out the water by using exit valve or high capacity dewatering system as provided by contractor without any extra cost to the Govt. before cleaning the mud and other deposits. (c) Filling up the over head reseviors full and feed the affected residential/OTM consumers enough water to sustain during the resevior cleaning period. (d) Second stage is cleaning all the algae formation inside the tank by using TERBAC G5 a laboratory tested branded chemical or as approved By Engnr - in charge complete all as directed. (e) Third stage is scrubbing the walls with mechanized scrubber & fresh water cleaning by high speed jet pump. (f) Fourth stage and first bacteria screening is Sterilization by using TERBAC-G5 a Govt Laboratory certified branded halogen compound or as approved By Engnr - in charge complete all as directed. (g) Fifth stage is cleaning the floor of the water tank by industrial vacuum cleaner.
(h) Sixth stage is the second bacteria screening and sterilizing method by using ultra violet ray with in the tank and kills all suspended bacteria (i) Seventh Stage of cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified branded strong oxidizing agent TERBAC- G65 or as approved By Engnr - in charge complete all as directed. (j) Fresh air to be blown into the tank for a period before allowing a person to enter. The cleaner should wear protective clothing, including gloves, a boots, Safety Helmet and glasses. Contractor should make sure someone remains outside the tank, next to the access hatch all the time in case the cleaner has an accident. The availability of gas masks and portable ventilators would be made available by the contractor at site during cleaning operation. (k) Remove the blockage from inlet/ outlet over flow pipes and ensure satisfactory distribution. (L) Writing of the date of cleaning of the water tank with white letters on black background. (m) All the required Tools and plants, lubricants/oils and materials will be supplied by the contractor during the work. Makes of service provider:Rays Cleantech Kolkata,Inus watertech Dist.24 Parganas North,Satya Enterprises Kolkata
- Ditto- all as serial item No. 2.00 above for OH Reservoir of capacity 50,000 gallons at 64 Pump House, Victoria Road Pump House, Ghorpadi Pump House No 1, Ghorpadi Pump House No 2, DAD Complex Pump House, SCOM Pump House and Manoj Panday Pump House.
- Ditto- all as serial item No. 2.00 above for OH Reservoir of capacity 30,000 gallons at Victoria Road Pump House
- Ditto- all as serial item No. 2.00 above for OH Reservoir of capacity 25,000 gallons at 64 Pump House.
- Ditto- all as serial item No. 2.00 above for OH Reservoir of capacity 10,000 gallons at SCSR comunication complex Pump House.
Cleaning and removing all scale old dirt from PVC/ RCC/ steel service tanks, at any floor of Md Accns, OTM Accns under GE (North) area with anti bacterial agent having six stage of cleaning process (i.e mechanically, dewatering, sludge removal, high pressure, vacuum cleaning, anti bacterial spray of tank capacity and writing of the date of cleaning of the water tank with white/Black letters complete all as specified and as directed by the Engineer-in-Charge for the capacity up to 500 litres. Note:-In case of airlocking of water tanks post cleaning contractor will normalise the water supply after the service to user's terminal by using requisite equipment/machinery/tools .The quoted rate deemed includes the same.
- Ditto- all as serial item No. 3.00 above but for Capacity 1000 Ltrs
- Ditto- all as serial item No. 3.00 above for Capacity 2000 Ltrs
- Ditto- all as serial item No. 3.00 above for Capacity 5000 Ltrs
All as serial item No. 3.00 but for Capacity 10000 Ltrs
Supply and replcement of suitable regular LID/ Tank covers made of fiber reinforced plastics/ heavy duty PVC for outdoor weather proof black in colour ECO polimer/modular build type, suitable clear opening type having minimum load bearing of 500 Kg with locking arrangement with PVC hinges fixed with the tank with MS screws at any floor of Md Accns, OTM Accns under GE (North) area complete all as specified and as directed by the Engr-in-Charge for the capacity up to 500-2000 litres.Make:Sintex,Supreme,Plasto
- Ditto- all as serial item No. 4.00 above for Capacity 5000-10000 Ltrs
Supply and fix in repairs 3 inches PVC butt hinges with locking arrangement using necessary Galvanised iron screws on PVC overhead water tanks kept on married accn and OTM bulding upto 4 storeyed all as directed and specified by Engineer-in-charge
Cutting green growing and grass by manual labour or by machine at all E/M water supply installation premisses and along the boundary fencing and removing rubbish from the site of work where didected not exceeding 100 mtr from the starting point. (The green growth shall be cleaned once in every three month and the measuremet shall be taken every time independently for executed quantity each time.
Supply and fix in replacement of synthetic metal PTMT Float valve heavy duty with suitable company designed length Aluminium Rod, HDPE Ball, SYMET PTMT ball cock of 15 mm dia including taking out the old one in over head reservoir located upto 4 stories buildings of OTM and Married Accomodation.
Supply and fix in replacement of of synthetic metal PTMT Float valve heavy duty with suitable company designed length Aluminium Rod, HDPE Ball, SYMET PTMT cock of 20 mm dia including taking out the old one in over head reservoir located upto 4 stories buildings of OTM and Married Accomodation.
Supply and fix in replacement of of synthetic metal PTMT Float valve heavy duty with suitable company designed length Aluminium Rod, HDPE Ball, SYMET PTMT ball cock of 25 mm dia including taking out the old one in over head reservoir located upto 4 stories buildings of OTM and Married Accomodation
S&F for rotational moulded polyethylene water storage tank 3 layer white colour water tank , non- toxic effect, algea formation protection (made frome virgin grade of polyethy-lene material which is duly stablized with anti-oxident plastic) of capacity 5000 litres, cylindrical vertical one piece moulded with closed top), the internal and external surfaces of tanks are smooth, clean and free from any hidden internal defects, hoisted and fixed in position including S & F necessary GI fittings, inlet/outlet washout, overflow pieces long nipples, checknuts & washer ,20 mm dia PTMT valves high pressure of PTMT with epoxy coated Aluminum rod & high-density plastic ball and 20 mm brass stop cock etc complete including dismantling existing water tank all as specified and directed.
M&L for preparation of internal plastered/ concrete surfaces of RCC overhead reservoir upto capacity 50000 gallons at different locations and applying two coats nontoxic, non-corrosive water proof coating inside the tank complete all as specified and directed. Make:- Sikagard-67, Dr Fixit Pidifine 2K, Berger Tankshield PW as certified by CFTRI, Mysore for potable water Note: - a) Surface preparation and application procedure shall be as per manufacturer’s guidelines and directions of Engineer-in-Charge. b) The paint used should not contain any harmful chemical content to pollute drinking water. A manufacturer certificate for the same is mandatory and contractor must produce the certificate as mentioned above before application to Engineer-in-Charge c) Painting will commence post arrest of leakage of the concerned reservoir.
M&L for preparation of internal plastered/ concrete surfaces of RCC / Stone Masonary UG sump of capacity 10000 to 150000 gallons at different locations and applying two coats nontoxic, non-corrosive water proof coating inside the tank complete all as specified and directed. Make:- Sikagard-67, Dr Fixit Pidifine 2K, Berger Tankshield PW as certified by CFTRI, Mysore for potable water Note: - a) Surface preparation and application procedure shall be as per manufacturer’s guidelines and directions of Engineer-in-Charge. b) The paint used should not contain any harmful chemical content to pollute drinking water. A manufacturer certificate for the same is mandatory and contractor must produce the certificate as mentioned above before application to Engineer-in-Charge c) Painting will commence post arrest of leakage of the concerned reservoir.
M&L for scrapping and removing old paint, stains, loose materials and algae-fungus growth then cleaning of surface with water using pressure washer machine, fill the crack with acrylic based textured cack filler and applying two coats of modified acrylic exterior emulsion paint of approved shade having silicon additives in paint over a coat of primer cum sealer having alkali resistance property diluted with water and mixed with bio block in ratio of (5:4:1) on the external surfaces of overhead RCC tank having height of 10 to 30 meters from ground level complete all as specified and as directed. (Note: (i) The contractor shall furnish 5 years performance warranty as per manufacturer of paint (ii) The work should be done by a company recommended applicator and he should be able to furnish stage wise on site technical reports from the concerned complany technologist).Make Of paints and primer: Berger Weathercoat,Asian Ultima strech,Dulux Weathershield Signature Note: (a) Necessary scaffolding and shuttering provision for works shall deemed included in quoted rates. b) Painting will commence post arrest of leakage of the concerned reservoir.
M&L for scrapping and removing old paint, stains, loose materials and algae-fungus growth then cleaning of surface with water using pressure washer machine, fill the crack with acrylic based textured cack filler and applying two coats of modified acrylic exterior emulsion paint of approved shade having silicon additives in paint over a coat of primer cum sealer having alkali resistance property diluted with water and mixed with bio block in ratio of (5:4:1) on the external surfaces of semi UG sump level complete all as specified and as directed. (Note: (i) The contractor shall furnish 5 years performance warranty as per manufacturer of paint (ii) The work should be done by a company recommended applicator and he should be able to furnish stage wise on site technical reports from the concerned complany technologist). Note: (a) Necessary scaffolding and shuttering provision of works shall deemed included in quoted rates. (b) Painting will commence post arrest of leakage of the concerned reservoir.
M&L preparation of old plastered or unplastered surfaces of wall incl cornices, pillasters by brooming down with steel wire brushing scrapping down smoke dust, moulds, moss and efflorescent salts and removing oily and greasy spots etc applying two coats of oil bound distemper on old surfaces of walls all as specified and directed.
M&L preparation of old plastered or unplastered surfaces of wall including cornices, plasters by brooming down with steel wire brushing scrapping down smoke dust, moulds, moss and efflorescent salts and removing oily and greasy spots etc applying two coats of oil bound distemper on old ceiling surfaces of walls all as specified and directed.
M&L for preparation of old decorated/ undecorated surfaces by sanding,brushing of mild steel applying two coat of hi gloss synthetic enamel paint on surface complete all as specified and as directed.
Material & Labour for providing and fixing in repairs stainless steel (Grade 304) railing/ladder made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement including necessary grouting in the existing slabs/walls/ceiling and cementing the same with necessay PCC /brick work as required at site while matching the existing surface all as directed and specified by Engineer in charge. Note : The work is also to be executed / overhead RCC tank of staging 30 meters above the ground level.
M&L for running welding of thickness n'exc 6mm in repairs complete all as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. Note : The work is also to be executed / overhead RCC tank of staging 30 meters above the ground level.
S&F framed work such as grill,channel, valve chamber cover, grating ,etc,with end of bars shouldered and/or riveted,or forged in to spikes, framed guard bars, flat iron, angle, barred iron doors, ladder, framed balusters,walk ways,railings,framework of water tanks and and similar work GDE Fe-410-0 or Fe-310-0, Note : The work is also to be executed / overhead RCC tank of staging 30 meters above the ground level.
S & F in repairs junction boxes with IP 66 rating having dimension 300 x 300 x 170mm made out of PVC, UV resistant, opaque lid including necessary DIN rail, PVC terminals and suitable cable knockout glands etc. all as specified and directed. Make Hensel Cat No. K 0201,sintex,
S & F in repairs 70 cm long ,150 mm dia PVC (SWR) pipes single socketed with and including bend and cowl suitable for 150 mm SWR pipe joining PCC with and including 1:2:4( Type B1) required at site for fixing over UG sump roof and overhead tank roof all as specified and directed.
M & L for Preparation of old plastered or unplastered wall surface for white washing and applying one coat white wash for internal, external surfaces of pump houses, valve chambers etc. complete all as specified and directed.
M & L for Preparation of old plastered or unplastered ceiling surface for white washing and applying one coat white wash for internal, external surfaces of pump houses, valve chambers etc. complete all as specified and directed.
M&L for Scrubbing the old paint by means of sand paper and preparing the steel surface for fresh painting and applying two coats of synthetic enamel paint over a coat of red oxide primer and writing the pertaining MES and SM no. on the pumpsets as specified for the following capacity :
Centrifugal pump set 3HP
Centrifugal pump set 5HP
Centrifugal pump set 7.5 HP
Centrifugal pump set 10 HP
Centrifugal pump set 15HP
Centrifugal pump set 20HP
Centrifugal pump set 25HP
M & L for rigid pvc sheet at least 3mm thick and density 700 kg per cum screen printed with suitable designs using Glossy PVC Ink and fixed using necessary nut ,bolts, washers etc.
S & F in repairs Expanded metal, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members with weight not exceeding 4kg per square meter complete all as specified and directed.
S & F in repairs Stainless steel wire cloth. 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples
Demolishing of concrete of any description and in any position not otherwise specifically provided and throwing the rubbish with in 50mtrs
M&L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) for coping including necessary formwork as required complete all as specified and as directed.
M&L for PCC 1:2:4 type B-2 (using 40 mm graded stone aggregate) for Cement concrete in foundations, filling and mass concrete including necessary formwork as required complete all as specified and as directed.
M & L for reinforced cement concrete (nominal mix) in slabs supported on walls,beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves including form work as required with type B!(1:2:4) 20 mm graded aggregate
M & L for TMT mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
Demolition of old u/s Brickwork or stone/boulder masonry but built in cement mortar or cement lime mortar
M&L for brick masonry with fly ash bricks exc 6 meter mean radius in cement mortar 1:6 all as specified and directed.
Taking down cement plaster of any thickness and rubbish removing from site to a distnace exc 50 metre but not exc. 100 metre all as directed.
M&L for rendering with 15mm thick in cement mortar 1:4 on fair surfaces of brick or concrete surafaces finshed even and smooth surfaces without using extra cement and all as specified and directed by Engr-In-Charge. Note : The work is also to be executed / overhead RCC tank of staging 30 meters above the ground level.
M& L for Rough excavation in soft/loose soil not exceeding 1.5 m deep and getting out, in soft & loose soil
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cms by using excavated soil.
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at level not exc. 1.5 m above starting point.
M & L for Writing letters alphepet or figures in (Block.Roman, Italic or Indian) n exc. 30 cm length with suitable font thickness, to write in a height of upto 30 mtr including arranements of scafoldings all as specified and as directed.
M & L for Writing letters in English Small/ Capital or figures in Roman/Arthimatic (Block. Roman, Italic or Indian) exceeding 30 cm and n exc. 60 cm length with suitable font thickness, to write in a height of upto 18 mtr including arranements of scafoldings all as specified and as directed.
Supplying and fixing 3mm thick, plain acrylic transparent sheet on wall including necessary fixing accessories like stainless steel fasteners, bolts etc., with all alteration at site incuding cutting, reaming etc. at water supply pump houses complete all as directed.
Removal of bio-degradable bee-hives wild growths from the structure tank and member of the overhead reservoir complete including wild bees with suitable application of fuming smoke or chemical fog application and applying a coat of alergent for keeping away or return of bee-hives (All the bee-hives on the tank shall be removed and cleaned) Note : The removal of bee-hives shall be carried out with total precautions so that wild bees do not get the time and opportunity to attack the public in the locality.
Material and labour for chemical and biological testing potable water from borewells as per IS 10500 (latest revision) sample from the nearest district Laboratory or municipal corporation P.H.E. complete all as specified and directed. Note:- The rate quoted by contractor includes the following: 1. Collecting water samples in sterlised containers from the location as directed by Eng-in-Charge 2. Transporting the collected sample immediately to the lab and submitting the test report to the Eng-in-Charge.
M&L for preparation of external surface Including grouting and rendering of damage surface & matching with the exiting surface of overhead /UG sump water storage tank of 60ft staging by scrapping all dirt’s dust, rust from roofs and overhead tank wall etc and then applying two coats of heat reflective paint With SRI >=122 even and smooth of white colour with colour bands all complete as directed by Engr-in-charge. Make of Paint : Luminx,Koolroof, Coolroof Note: Contractor has to ensure the safety of the working personnel and the quoted rate includes the rate of tools and equipments needed for the job.
Supply and fix in replacement on-line pressure boosting pump, outdoor, weather proof electrically operated 240 volts, 50 Hz fixed to 15/20 mm dia of capacity Head 10 mtrs Flow rate-35 LPM power input 0.1 KW with three opearting position OFF/AUTO/MANNUL and componants of ceramic radial Ball Bearing, copper stator winding, EPDM rubber gasket, Aluminium oxide Shaft, carbon trust Ball Bearing, composit PP30% GF impeller including the integrated flow switch starts or stops the pump when a tapping point is turned on or off including, electrical connections, relaying of pipe lines, GI fittings, and removal of old unsv one complete all as specified and as directed. Make Wilo cat no.PB88,Kirloskar,KSB
Supply and fix in replacement on-line pressure boosting pump, outdoor, weather proof electrically operated 240 volts, 50 Hz fixed to 15/20 mm dia of capacity Head 16 mtrs Flow rate-50 LPM power input 0.2 KW with three opearting position OFF/AUTO/MANNUL and componants of ceramic radial Ball Bearing, copper stator winding, EPDM rubber gasket, Aluminium oxide Shaft, carbon trust Ball Bearing, composit PP30% GF impeller including the integrated flow switch starts or stops the pump when a tapping point is turned on or off including, electrical connections relaying of pipe lines, GI fittings, GI fittings and removal of old unsv one complete all as specified and as directed. Make Wilo cat no. PB 200,Kirloskar,KSB
Supply and fix in replacement water lifting and booster pump 1.5 Hp single phase suction with necessary factory fabricated auxillary tank and discharge,( 25 mm x 25 mm ) total head upto 10-42 mtr, capcity upto 75 - 6 LPM monoblock, multiple noryl/brass impellar pump type suitable for 230 volts with all necessary fittings including copper cable upto 5mtr.Including removol of old unsv one complete all as specified and as directed Make kirloskar CPBS 84424H/V,KSB KSB KHM 406,Texmo ADBS 44 HS / 60L
M&L for making hole and fixing the metallic packer for injecting hydrophobic PU foam and Sealer as per manufacturer’s instruction.(Avg. 1 metallic packer per sq mtr.) to provide next course of application to repair leakage all as directed by Engr in Chagre Makes of service provider:Rays Cleantech Kolkata,Inus watertech Dist.24 Parganas North,Satya Enterprises Kolkata
M&L CORESEAL 357A/ CORESEAL 357 CAT for plugging live leakage of semi UG sump slab, floors junction and walls (combined unit) by using construction chemical methods such as, HYDROPHOBIC PU Foaming agent all as directed by engr in charge Make : M/s FosrocChemicals,Ms IWL india Ltd,,MS Berger Paints Ltd Makes of service provider:Rays Cleantech Kolkata,Inus watertech Dist.24 Parganas North,Satya Enterprises Kolkata
M&L for second course injection of CORESEAL 135A/ CORESEAL 135B (Resin) Make : Build core chemicals or equivalent all as directed by engr in charge Makes of service provider:Rays Cleantech Kolkata,Inus watertech Dist.24 Parganas North,Satya Enterprises Kolkata
Note : 1. Performance security:- Refer Condition 22 of Special Conditions. 2. Quoted Contract Sum shall be arrived at after deducting the amount of Credit Schedule (refer Schedule of Credit in pdf form for quantity, rate and amount etc.) for old unserviceable materials retrieved from site.
visionenterprises
Dheer Engineering
SHRI SWAPNAYOG ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .