Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.6 LAccepted-AOC NIVADA TIVAYA ROAD TIVYA MUST BUS STOP VILLAGE KHATAULI SAHARANPUR UP 247001 | SAHARANPUR | SAHARANPUR | UP | 247001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹24.4 L+₹4.8 L (24.6%)Rejected-Finance 13 218 MASJID EXTEN SADAR BAZAR | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹26.9 L+₹7.3 L (37.3%)Rejected-Finance | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹27.0 L+₹7.4 L (37.8%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹32.5 L+₹12.9 L (65.8%)Rejected-Finance FLAT NO 602 THE ELEPHANT HEAD CGHS LTD PLOT NO 41 OPP AYUSHMAN HOSPITAL DWARKA SECTOR 10 SOUTH WEST DELHI 110075 | SOUTH WEST | DELHI | 110075 | L5 | Rejected-Finance Not lowest bidder |
Tender Value
₹39.5 L
EMD Value
₹79,000
Closing Date
15 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE South Delhi Cantt-10
GE South Delhi Cantt-110010
REPAIR/REPLACEMENT OF E/M NATURE OF WORKS AT VARIOUS MD/OTM ACCN OF BANA SINGH, 180 MAHIPALPUR, YOGINDER VIHAR, 13 KUMAON, 5/11 GR, 227 FD WKSP, SIG COY AND 35 INF BDE UNDER AGE E/M OF GE (SOUTH) DELHI CANTT-10
2022_MES_524806_1
GE/DS-26/2022-23
Open Tender
Civil Works
Item Rate
270 days
GE South Delhi Cantt
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE South Delhi Cantt
₹79,000
Yes
25 Jun 2022
18 May 2022
17 Jun 2022
18 May 2022
15 Jun 2022
1 Jun 2022
60 days
Amount
Attending complaints for checking the existing electrical items for continuous electric supply including carrying out minor repair etc as required to make the item functional and replacing fuse, small pieces of copper wire, copper cable as of suitable size at site, insulation tape roll etc. Attending minor repair such as testing, electric connections, fittings, nut, bolts and screws etc to ceiling fan, exhaust fan at its initial position (without taking down) etc, emergent complaints i.e. no light, earth leakage, short circuit, neutral break in mains/sub mains/internal circuits of existing electrical system of main building/block and making continuous electric supply including carrying out minor repairs etc. required to make the system in order/functional with insulation tape roll, copper thimbles, glands, earthing wire as required at site complete all as specified and directed by Enigneer-in-Charge. Notes :- This item is applicable only where no store is required. 1. The site for attending complaints are BANA SINGH, 180 MAHIPALPUR, YOGENDER VIHAR, 13 KUMAON, 5/11 GR, 227 FD WKSP, SIG COY AND 35 INF BDE. Contractor shall provide minimum four tradesmen (electrician) to attend the complaints all the above areas in all working days between 0830Hrs to 1700Hrs including holiday and sunday. 2. Contractor shall ensure the security passes for his staff, to be obtained from concern authority for attending complaints. 3. The contractor will ensure that the team of electricians with necessary tools bag shall always remain present at complaint cell to attend the complaints. 4. A recovery of Rs. 500/- for not attending the complaint upto 04 hours and after 04 hours Rs. 1000/- shall be recovered from the contractor due. 5. All the complaint slip, register & other connected document will be provided by the contractor without any extra cost. 6. Proper record (date wise) of complaints received & rectified by the contractor and the same may be asked for verification at the time of payment of each RAR/Bill. 7.The above tradesmen shall not be utilize for the complaints where material is required and these complaint shall be measured and paid seperately as S&F here-in-after.
S&F in replacement of switch piano flush type 6 Amps SP one way complete all as specified and directed by Engr-in-Charge.
S&F in replacement of switch piano flush type 6 Amps SP 2-way complete all as specified and directed by Engr-in-Charge.
S&F in replacement bell push, flush type 6 Amps complete all as specified and directed by Engr-in-Charge.
S&F in replacement of socket outlet 6 Amps flush mounted piano type 5 pin multi purpose complete all as specified and directed by Engr-in-Charge.
S&F in replacement of switch piano flush type 16 Amps SP one way complete all as specified and directed by Engr-in-Charge.
S&F in replacement of socket outlet 2 in 1 (multipurpose) 6 pin 6 and 16 Amps flush mounted type complete all as specified and directed by Engr-in-Charge.
S&F in replacement of lamp holder bakelite insulated body with back plate suitable for batten fitting complete all as specified and directed by Engr-in-Charge.
S&F in replacement ceiling rose surface Bakelite 65x25 mm two to three terminals complete all as specified and directed by Engr-in-Charge.
S&F in replacement of fan regulator electronic, stepped type, Switch type, suitable for ceiling fan 1200/1400mm sweep complete all as specified and directed by Engr-in-Charge.
S&F in replacement of switch socket combination 2-in-1, 6 Amps flush type complete all as specified and directed by Engr-in-Charge.
S&F in replacement of switch socket combination 2-in-1 6 & 16 Amps flush type complete all as specified and directed by Engr-in-Charge.
S&F in replacement of plug top 15/16 Amps, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of PVC casing caping of size 20 x 12mm of ISI Mark or as per manufacturer design with all accessories for surface wiring complete all as specified and directed by Engr-in-Charge.
S&F in replacement of bell Ding dong type 230 volts single phase complete all as specified and directed by Engr-in-Charge.
S&F in repair LED 10 watt white Bulk head in engineering plastic housing with clear prismatic including all accessories connecting up twisted flexible copper conductor cable of suitable size of 230 V, 50 Hz complete all as specified and directed by Engr-in-Charge.
S&F LED Batten T-5 fitting 20 watt LED White, indoor decorative aluminum extruded T5 LED battern -integrated type complete in replacement of old unsv existing 36 Watt tube light fitting, complete all as specified and directed by Engr-in-Charge.
S&F LED Integrated Batten T5 10 watt - 2FT White, indoor decorative aluminum extruded T5 LED battern -integrated type with fliexble wire complete in replacement of old unsv existing 18 Watt tube light fitting complete all as specified and directed by Engr-in-Charge.
S&F surface mounting round/square shaped LED downlighter with PDC aluminum housing 6 Watt LED lamp type in replacement of old unsv existing CFL fitting any type from ceiling of stairs/common areas, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of wall light fixture any type with Wall mounting fitting City-4, Decorative wall light fixture made up of Polycarbonate, of B-22 base including 12 Watt LED Bulb of 6.5K complete all as specified and directed by Engineer in Charge.
S&F Recessed/surface mounting 36 watt 2' x 2' flat LED panel fitting with soft light and glare free symetrical ilumination suitable for RCC/POP ceiling supplied with wedge bracket to fix in existing ceiling in replacement of existing old unserviceable CFL fitting any type from ceiling of common areas and making good disturbed surface/POP ceiling to match and getting electrically connected the fitting with switch board for suitable size of PVC copper wire complete all as specified and directed by Engr-in-Charge.
S&F LED Building security light fitting 30W on existing bracket in replacement of old unsv existing security light fitting any type complete all as specified and directed by Engr-in-Charge.
S&F in replacement Circuler Hylam/PVC Sheet upto 10 Cm dia of 3 mm thick (for using as Junction box Cover) including screws and cup washer complete all as specified and directed by Engr-in-Charge.
S&F in replacement of PVC insulated FRLS single core with stranded copper cable of size 1.5 Sqmm for any type of wiring as per site requirement complete all as specified and directed by Engr-in-Charge.
S&F in replacement of PVC insulated FRLS single core with stranded copper cable of size 2.5 Sqmm for any type of wiring as per site requirement complete all as specified and directed by Engr-in-Charge.
S&F in replacement of PVC insulated FRLS 3 core with stranded copper cable of size 2.5 Sqmm for any type of wiring as per site requirement complete all as specified and directed by Engr-in-Charge.
S&F in replacement clamp with rubber real for hanging ceiling fans of 1200/1400mm sweep as per sample complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCCB 3 pole, 415V, Adjustable type,125 amps with breaking capacity complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCCB 3 pole 160 Amps 36 KA 415 Volts with breaking capacity 36 KA, complete all as specified and directed by Engr-in-Charge.
S&F in replacement for MCB SP 06 to 32 Amps 240 Volts, 10 KA, `C' curve, complete all as specified and directed by Engr-in-Charge.
S&F in replacement for MCB SPN 40 Amps, 240 Volts, 10 KA, `C' curve, complete all as specified and directed by Engr-in-Charge.
S&F in replacement for MCB SPN 63 Amps, 240 Volts, 10 KA, `C' curve, complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCB TPN 63 Amps 415 volts, 'C' Series 10 KA complete all as specified and directed by Engr-in-Charge.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc. complete all as specified and directed by Engr-in-Charge.
M&L for point wiring complete, standard copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable in and including suitable concealed PVC conduit medium grade and sunk in pressed steel terminal boxes of required size with top cover 3 mm thick plastic/laminated sheet of required color with screwed and cup washer complete with all accessories including 1.5 Sqmm standard copper conductor PVC unsheathed cable earth and connected to earth dolly complete all as specified and directed by Engr-in-Charge. Note :- In existing conduit wiring new conduit will be added where there is a burnt/blokage/damage to the existing conduit including bends/elbows/tees/Junction boxes. (a) One light / fan/bell point controlled by one switch SP, one way, 230 volts.
All as above Srl item No. 35 above but one 3 pin socket outlet 5/6 Amps on same board.
All as above Srl item No. 35 above but one socket outlet 5/6 Amps on independent board.
All as above Srl item No. 35 above but here-in-before one power socket 15/16 Amp with cable 2.5 Sqmm for phase & neutral and for earth 2.5 sqmm.
S&F in replacement MS fastner bolt 8mm dia and 100mm (Min.) long for fixing geyser/ Exhaust fan/Bldg security light etc with nut and washer complete all as specified and directed by Engr-in-Charge.
S&F in replacement of sub main wiring using single run PVC FRLS grade insulated unsheathed, multisrand copper conductor cable 2 runs of 4 Sqmm for Phase and neutral and 1 run of 4 Sqmm for earth wire drawn through existing PVC concealed conduit and including replacement of unsv pressed steel terminal boxes of in wall as per suitable/existing dia with fittings like tees, bends junction/terminal boxes etc as per site requirement and all as directed by Engr-in-Charge.
S&F in replacement of sub main wiring using single run PVC FRLS grade insulated unsheathed, multisrand copper conductor cable 2 runs of 6 Sqmm for Phase and neutral and 1 run of 6 Sqmm for earth wire drawn through existing PVC concealed conduit and including replacement of unsv pressed steel terminal boxes of in wall as per suitable/existing dia with fittings like tees, bends junction/terminal boxes etc as per site requirement and all as directed by Engr-in-Charge. Note for Srl item No 40 to 41 :- (a) Two runs of main cable and one run of earth cable all together shall be considered as one length. (b) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
M&L for Earthing complete with galvanized steel earth plate 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate n.less than 1.5 m below normal ground level, connected to galvanized iron wire 4 mm as earthing lead by means of bolts, nuts, check nuts & washers of galvanized iron or steel besides building at all joints as shown in drgs and including excavation and earth work, GI pipe light grade 25mm bore of protection of GI wire from earth electrode, supply and laying charcoal dust, common salt, PCC (1:2:4) type B-1 Chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type B-1using 20 mm graded stone aggregate Reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia , PGI funnel and wire mesh , 20 mm dia GI Pipe light grade for watering complete all as shown in drg and connected to earth test point including testing complete all as specified and directed by Engr-in-Charge.
Note:- The contract sum shall be after deducting the amount of Credit shown in Credit Schedule of this Tender.
verma enterprises
ramveer Singh
M/s Adhikari construction co.
NEERU ELECTRICALS
Microsys Controls India
Surjit and Sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .