| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.8 LAccepted-AOC 30 INDUSTRIAL AREA KOKAR RANCHI 834004 JHARKHAND | RANCHI | JHARKHAND | 834004 | L1 | Accepted-AOC MS Raj Construction is lowest and accepted | |
| 2 | L2₹29.8 L+₹25,278.95 (0.86%)Rejected-Finance 337 B ROAD NO 04 ASHOK NAGAR RANCHI 834002 JHARKHAND | RANCHI | JHARKHAND | 834002 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹30.1 L+₹60,340.52 (2.04%)Rejected-Finance 3B CHANDRALOK APARTMENT 3RD FLOOR KUTCHERY ROAD RANCHI JHARKHAND PIN 834001 | RANCHI | JHARKHAND | 834001 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹30.6 L+₹1.1 L (3.85%)Rejected-Finance B 1203 VRINDA RESIDENCY BARIATU ROAD RANCHI JHARKHAND 834009 | RANCHI | RANCHI | JHARKHAND | 834009 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹32.1 L+₹2.6 L (8.87%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹42.9 L
EMD Value
₹85,800
Closing Date
13 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Y K GOUR
HQ CWE RANCHI MES,DIPATOLI
ADDN/ALTN TO EXISTING HT NETWORK AT C POWER HOUSE AT DIPATOLI MIL STATAION UNDER GE DIPATOLI
2023_MES_632949_1
80599/1506/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
GE DIPATOLI
Please refer Tender documents
6 documents required · 6 mandatory
₹500
Yes
GE RANCHI
₹85,800
Yes
HQ CWE RANCHI MES,DIPATOLI
17 Feb 2024
15 Dec 2023
20 Jan 2024
15 Dec 2023
13 Jan 2024
30 Dec 2023
15 Dec 2023 - 22 Dec 2023
22 Dec 2023
Amount
Supply, laying testing and commissioning of UG HT cables, 11000 volts grade, 3 core 95 sqmm (Earthed), XPLE insulated and PVC sheathed, steel strip, armoured, with multi stranded aluminum conductor, heavy duty conforming to latest relevant IS, cables laid in trenches/ducts/under plinth floors passing through pipes etc, fixed on wall complete all as specified and directed.
Excavation in trenches in soft/loose soil n.exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting out for taking out / laying of cable complete all as specified and directed.
Supply and providing sand cushioning with dry clean sand 15 cm below cable and 8 cm above the cable complete all as specified and directed. Note : Punned thickness shall be measured for the purpose of payments.
Supplying and laying unreinforced precast cement concrete cable covers, Class HVP, Type-1, with peak, size 300 mm x 180 mm x 40 mm in trenches for cable protection, embossed with "HT 11 KV HT ELECTRIC" on the top surface complete all as specified and directed .
Removing surplus excavated material not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
M&L for trenchless boring under road crossings/foot paths by manual / Boring machine with dia 200 mm complete all as specified and directed at site.
Supply and fix in replacement of 100 mm bore GI pipe light grade fixed on pole /trenches/wall/road crossing etc complete with clamp nut bolt etc all as specified and directed at site.
M&L for PCC (1:4:8) type D2 using 40 mm graded stone aggregate in foundation mass concrete and filling including weathering slightly rounded or chamfered complete with necessary use and waste fo form work complete all as specified and directed at site.
M&L for mild steel as in cross arms bracing supports clamps and back planes fabricated from structural steel section including nut, bolts washers welding welding drilling holes for bolts in any shape and size as indicated or directed and inclusive of one primer coat one under coat one finishing coat of aluminium paint complete. paint complete to support the cables all as specified.
S&F Cable route indicator / Marker made up of PCC Block in 1:3:6 (20 mm graded stone aggregrate) of size 900mm x 300mm x 100 mm thick with "DANGER / 11 KV CABLE / MES or DANGER / 11 KV HT JOINT / MES" embossing on cable route Indicator / Marker including painting as per approved colour and buried in ground 45 Cms including necessary earth work (as required / ordered at site) complete all as specified and directed.
Supply and Fix Cable jointing kit 11 KV grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 95 sqmm indoor / outdoor type complete all as specified and directed.
Supply and Fix Cable jointing kit 11 KV grade cable for outdoor termination Heat shrinkble push on type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 3 core x 95 sqmm complete all as specified and directed.
M &L for GI Earthing complete with GI earth plate electrode 60cm x 60cm x6 mm buried directly in ground verticvally to size of depth not less than 0.90x 0.60 x 2.25 mtr below ground level with top edge of the plate at a depth not less than 1.5 mtr below ground level, earth plate connected to galvanised earth strip of size 25x3 mm, 7.5 mtr long by means of brazing nuts, bolts, check nuts, & washers ,testing of completion (drawn in earth lead protection pipe light gade GI of size 32/40 mm dia) by means brazing at both edges with vertical plane of electrode all as shown in plate No 3 of SSR Part - I connected to earthing lead with Main switch/main control board,filling with charcoal dust 200 Kg, and common salt 100 KG , including necessary excavation and earth work in any type of soil ,perforated watering pipe,funnel with wire mesh,earth lead protection pipe light grade PCC chamber 1:3:6 type C1 (for even finish on both the faces) and RCC cover 1:2:4 Type B1,450 x450 x50 mm thick with 6 mm dia CTD bars 150 mm c/c with 2 Nos of handles of 10 mm dia steel rod all as specified and directed and testing on completion and connected to equipment with lugs and screw nuts etc all as specified and directed by EIC Note : (i) 7.5 RM GI earth wire deemed to be included in quoted rates beyond 7.5 RM wire shall be measured and paid separately. (ii) Earth resistance of earth pit should be not more than 02 Ohms on testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. (iii) Rate quoted by the tenderer is deemed to included salt & Charcoal upto & above 450 mm top of GI Plate.
S&F GI strip of size 25x4 mm connected both ends with necessary bolts, nuts & washrs complete all as specified and directed.
Dismantling of ACSR conductor of any size from 11 kV HT pole complete all as specified and directed.
Dismantling insulators any type, any size from 11 kV HT pole complete all as specified and directed.
Dismantling concrete poles/ struts, any size complete all as specified and directed.
Dismantling steel poles of HT 11 KV Steel tubular Poles complete all as specified and directed.
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use with in 50m complete all as specified and directed.
Excel Enterprises
ASSOCIATED BUILDCON LLP
arics infrastructure
M/S Akash Enterprises
MONA GENERATOR SEVICES PVT. LTD.
RC GUPTA AND SONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .