Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.7 CrAccepted-AOC FLAT NO 2450 KRISHNA COLONY JIND 126102 | JIND | HARYANA | 126102 | ₹2.7 Cr | 1 | Accepted-AOC LOWEST RATES |
| 2 | 2₹2.8 Cr+₹5.5 L (2.01%)Rejected-AOC 858 SECTOR 23 127021 2021R109 | BHIWANI | HARYANA | 127021 | ₹2.8 Cr+₹5.5 L (2.01%) | 2 | Rejected-AOC HIGHER RATES |
| 3 | 3₹2.8 Cr+₹7.3 L (2.66%)Rejected-AOC 81 ARYA NAGAR ASSANDH ROAD PANIPAT HARYANA 132103 | PANIPAT | HARYANA | 132103 | ₹2.8 Cr+₹7.3 L (2.66%) | 3 | Rejected-AOC HIGHER RATES |
| 4 | 4₹3.1 Cr+₹34.7 L (12.7%)Rejected-AOC HSVP PANCHKULA | PANCHKULA | HARYANA | 133301 | ₹3.1 Cr+₹34.7 L (12.7%) | 4 | Rejected-AOC HIGHER RATES |
Tender Value
₹2.9 Cr
EMD Value
₹5.8 L
Closing Date
20 Dec 2021, 3:00 pmClosed
EE
PHED NO.1 JIND
Const. of 400 mm id RCC NP2 pipe inlet channel 2 No. Brick Lining SS Tank RCC SS Well for Raw and Clear Water 2 No. RCC HLT 2 No. RCC FB 2 No. RCC CWT Pump Chamber Boundary Wall 1 No. RCC UGCWT at BStn. 1 No. Pump chamber Boundary wall at BStn. lay
2021_HRY_199582_1
EIC9199623112021
Open Tender
Civil Works
Works
365 days
JIND
Please refer Tender documents.
2 documents required · 2 mandatory
₹15,000
₹5.8 L
Yes
20 Jan 2022
11 Dec 2021
20 Dec 2021
11 Dec 2021
20 Dec 2021
11 Dec 2021
Amount
Supply and erection of Horizontal spindle spilit casing type pumping sets of minimum (4) star rating duties directly coupled to AC squirrel cage induction type motor with 1440 RPM, 3 phase, 50 Hz and accessories as described in Schedule No. II with priming arrangement and complete base frame as per IS marked complete in all respects. Raw Water Pump Set 1300 LPM with 12 mtr. head
Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powdered coated of approximate size 500 X 1200mm and 400mm deep having following accessories complete in all respects as per approved NIT. (a) Incomer switch 200 Amp. b) Aluminum bus bar chamber of 300 Amp. capacity c) Volt meter 100X100 mm ranged 0 to 500 V (AE/KAPPA/L&T) ((i) Indicating Lamp-One Set
Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powdered coated of approximate size 1200X900mm and 400mm deep having following items:-A) For Raw water pump sets for 1300 LPM x 12 M head = 2 Nos. (a) Main switch 63 Amp.- 2 Nos. (L & T Siemens, ABB).(b) Volt meter 100X100 mm range 0 to 500 volt 1 No. (AE/KAPPA/L&T)(c) Amp. meter 100X100 mm range 0 to 100 Amp. 2 Nos. (AE/KAPPA/ L&T)(d) CT 100/3 Nos. (AE/KAPPA/ L&T)(e) VSS 1 No. & ASS 2 No. each approved make (f) SPP 1 No. of approved make(g) Motor starter, star delta 2 Nos. for 1300 LPM x 12 M Head Motor (L&T Simens, AAB)(h) Capacitor of suitable capacity - 2 Nos. (i) Indicating Lamp-One Set( j) Change over switch 63 Amp. = 1 No.
B) For Clear water pump sets for 1300 LPM x 40 M head = 2 Nos. each (a) Main switch 63 Amp.- 2 Nos. (L & T Siemens, ABB). (b) Volt meter 100X100 mm range 0 to 500 volt 1 No. (AE/KAPPA/L&T) (c) Amp. meter 100X100 mm range 0 to 100 Amp. 2 Nos. (AE/KAPPA/ L&T) (d) CT 100/3 Nos. (AE/KAPPA/ L&T) (e) VSS 1 No. & ASS 2 No. each approved make (f) SPP 1 No. of approved make (g) Motor starter, star delta 2 Nos. for 1300 LPM x 40 M Head Motor (L&T Simens, AAB) (h) Capacitor of suitable capacity - 2 Nos. (i) Indicating Lamp-One Set ( j) Change over switch 63 Amp. = 1 No.
Supply, erection, testing of ISI marked copper wire for 8 No. motors with under ground system in PVC and flexible pipes copper wire size 6 Sq mm complete in all respects with accessories like thimble etc. complete in respects. A) 6 sq mm 3 core
B) 10 sq mm 3 core
Providing, erection, testing of reputed make LED light 100 watts with fitting and accessories complete in respects.
Supply, erection, testing of light fittings including wire in the Pump Chamber with material up to 10 points including switch, button, plug, PVC conduct pipe and Copper wire etc. as per approved specifications complete in respects.
Operation and maintenance for the complete scope of work mentioned in the DNIT (Disinfection material supplied by the PHED) as per schedule- IV for a period of 5 years after 12 months during defect liability period and 3 months trial run period. (will be charged to the A/mtc. estiamte). complete in all respects. a) Operation and maintenance during defected liability period (Operation only) after 3 months trial run period.
For 1st year Operation and maintenance after defect liability period.
For 2nd year Operation and maintenance
For 3rd year Operation and maintenance
For 4th year Operation and maintenance
For 5th year Operation and maintenance
Bidder Name
Amount
M/S AAR PEE CONSTRUCTION COMPANY JIND(GSTN-NA)
Rajesh Kadiyan Contractor(GSTN-NA)
Himmat Singh Contractor(GSTN-NA)
M/S SHREE BALAJI BUILDERS(GSTN-NA)
Rajesh Kadiyan Contractor
Himmat Singh Contractor
M/S AAR PEE CONSTRUCTION COMPANY JIND
M/S SHREE BALAJI BUILDERS
Rajesh Kadiyan Contractor
Himmat Singh Contractor
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .