Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC NAGAON ASSAM | NAGAON | ASSAM | ₹1.5 Cr | L1 | Accepted-AOC Successful bidder |
| 2 | L2₹1.5 Cr+₹51,029 (0.34%)Rejected-AOC | ₹1.5 Cr+₹51,029 (0.34%) | L2 | Rejected-AOC Unsuccessful bidder |
| 3 | Rejected-Technical | - | - | Rejected-Technical Technically not qualified |
Tender Value
₹1.5 Cr
EMD Value
₹3.0 L
Closing Date
27 Dec 2021, 2:00 pmClosed
SE Guwahati Building Circle-II Chandmari
SE office Guwahati Building Circle-II Chandmari
30 Bedded O2 supported bed, 8 bedded HDU 4 bedded ICU ICU beds in Public Healthcare facilities including 20 paediatric ICU beds Total 10 ICU beds at B.P. Civil Hospital, Nagaon District under ECRP-II
2021_PWBNH_23763_1
SE/BII/Tech/NHM_ICU_BP CH_ECRPII
Open Tender
Civil Works - Building
Item Wise
60 days
BP Civil Hospital, Nagaon
Please refer Tender documents.
6 documents required · 6 mandatory
₹4,600
Assam State Road Board Maintenance (Roads) Fund
₹3.0 L
Yes
SE office Guwahati Building Circle-II Chandmari
4 Jan 2022
20 Dec 2021
27 Dec 2021
20 Dec 2021
27 Dec 2021
20 Dec 2021
22 Dec 2021
Amount
Demolishing brickwork including stacking of serviceable materials and disposal of unserviceable materials as directed for all levels
Dismantling and removing the existing door and window frame (chowkath) both wooden and steel of different sizes without damaging the walls and removing the frame and necessary repairs to the edges of the walls as directed for all levels. (i) Area of door/window up to 3.00 m2
Demolishing CC floors of various thickness including top layer and base course and disposal of debris as directed for all levels.
Preparing the RCC surface in roof slab, chajjas, terraces, sunken slabs, septic tank, OH tank, raft slab, walls etc. by thoroughly cleaning with wire brush etc. followed by power washing for making the surface absolutely free from any foreign particles like dust, oil, grease etc. and allowing surface to dry complete as directed at all levels.
Supplying, providing, mixing and laying over waterproofing layers/ coatings with concrete screed of average 30mm thick or as per drawings/ requirements in proportion 1:2:4 (1cement : 2fine aggregate : 4coarse aggregate) (by volume) with 10mm and down well graded aggregates and admixed with a normal plasticizer like Master Plast PL-1 of Choksey Chemicals /Dr. Sealkit Normal Plast (Asian Chemicals)/Rheomac 707 of BASF @ 0.3% by weight of cement and thereafter scoring the top surface of the concrete screed @ 200mm c/c as specified and directed by the Department.
Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.
Plain Cement concrete Works with coarse aggregate of size 13 mm to 32mm in foundation of steps, footing of column and plinth beam as directed and specified including curing complete (shuttering where necessary shall be measured and paid separately) in prop. 1 cement:3 Sand :6 Coarse aggregate by volume. (c)100mm thick
Plain cement concrete floor base in prop1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete. (b) 50mm thick
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I)Using Mixer Machine (A)In substructure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. (ii)M20 grade concrete or Prop. 1:1.5:3
ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing.b) M20 grade concrete or Prop. 1:1.5:3
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc.(ii)Using 25mm thick plank
Sides of tie beams, grade beams etc. at or below ground level.(ii)Using 25mm thick plank
Columns, Pillars, Posts & Strut (a)Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face (ii)Using 25mm thick plank
Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like.(a) Floors etc. upto 200mm in thickness.(ii) Using 25mm thick plank
Providing brick soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a).Brick on flat soling.
112 mm thick 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (a). In cement mortar in proportion 1:4.(1 cement:4 sand)
Brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed in substructure upto plinth level ( in prop. 1:4 )
Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) a) Normal range Somany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make ii) Of size 600mmx600mm and above
18 mm thick Marble stone slab flooring of sizes 1200x1200 including treads and risers of steps, skirting, laid over 20 mm thick base of cement plaster 1:6 (1 cement : 6 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with marble slab of specified quality and shade at all levels. (III) Kumari Slab
Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls). a) Normal range Somany/ Orient/Nitco/Asian Make i) Of size 200mmx200mm and above
15 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. (b). In cement mortar 1:4
15 mm thick Cement plaster in single coat on rough side of single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. (b). In cement mortar 1:4
Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (a) 15 mm thick
Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) pre-coated G.I. angle size 24mmx24mmx80mm thick fixed to the brick wall/ partition at the perimeter of ceiling with nylon sleeves and screws, at 610mm c/c. Then suspending main 'T' section (bottom pre-coated) size 24mmx38mmx0.70mm and 3600mm long from the soffit in one direction with the help of metal Rawl Plug. Soffit cleat and G.I. Rod 4mm diameter with galvanised level clip 1220mm c/c G.I. cross (C) BPB Grid ceiling system with plain Gypboard Tiles 8.0 mm thick.
Providing, fitting and fixing 10mm thick Bison Panel(Cement Bonded Particle Board) door shutters fixed to 100mmx38mm wooden frames with necessary hinges, screws, bolts etc. including painting of door shutters (one coat primer and two coats painting) complete as specified and directed by the department for all floors (Door fittings to be measured and paid separately). (b)One side laminated
Providing, fitting and fixing powder coated pressed steel door frame made of 1.25mm/ 1.6mm thick sheet of various sizes with necessary hinge jamb, lock jamb, head and steel base ties at the bottom of the frame. The whole frame shall be welded or rigidly fixed together by mechanical means with base ties of pressed mild steel angle of size 20x20x1.25mm thick. Frame to be filled up with 1:4:8 P.C.C. after fitting the frame with brick/ concrete works etc.complete as directed by the department for all levels. (P.C.C. to be measured and paid for seperately). (a) 1.25mm thick sheet (iv) Size 125mm x 60mm (Double rebate)
Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ opening with M.S. flats at required spacing in frame all round, squre or roundM.S.bars with round headed bolts and nuts or screws. I. Plain grill, ((c) Fixed to Brickwork/P.C.C/R.C.C.
Providing fitting, hoisting and fixing of roof trusses including purlins fabricated out of M.S. black-tubes conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed.
Applying one coat of distemper primer of approved brand and manufacture on wall surface after throughly brushing the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
Distempering with dry distemper of approved brand and manufacture(two coats)and of required shade on new wall surface to give an even shade, over and including priming coat of whiting after throughly brushing the surface free from mortar dropings and other foreign matter and including preparing surface even and sand papered smooth.
a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface (two coats) to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials.
Applying priming coat over new wood based surfaces up to 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting.(a). With ready mixed paint , Wood primer (pink)
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping. (i).Surfaces over 100mm in width or girth. a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. a). With ready mixed "red-lead/ red oxide" primer.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (i).Surfaces over 100mm in width or girth. a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Providing corrugated galvd. Iron sheet roofing of TATA SHAKTEE / SAIL including fitting and fixing necessary galvd. J or L hooks, bolts and nuts 8 mm dia with bitumen washer 25 mm dia x 3 mm thick and 1.6 mm thick limpet washer complete excluding cost of roof truss, purlin etc.(roof trusses and purlin etc.to be measured and paid separately) (a) 0.45 mm thick
Providing galvd iron ridging of TATA SHAKTEE / SAIL including supplying and fixing necessary galvd screws/washers etc. complete as directed. (C) 0.63 mm thick,(ii) 230 mm lapping
Pre construction anti - termite treatment with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water. This provides emulsion containing 1% chloropirophose solution (by weight) applying in the entire levelled area after plinth filling and before laying floor, tricel solution @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.
Providing, fitting and fixing 24mm/ 29mm thick polymer reinforced moulded PVC door shutters fixed to the chowkath with necessary hinges, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid seperat(A) 24mm thick
Providing, fitting and fixing PVC door frame of Duroplast make DPF-5060 make suitable for DPS-3720 made from extruded PVC multichamber hollow section having dimensions of 50mmx60mm (Toletance + 1mm). Horizontal and vertical sections shall be joined by ste
Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels. (b)3 Track sliding window (i)6mm clear glass
Providing, fitting and fixing anodised aluminium windows and ventilators of standard sections without horizontal glazing bars joints mitred and welded (manufactured to relevant IS specifications) fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels. (Cement concrete to be measured and paid separately).a)Side hung and Top hung windows and ventilators ii)5mm frosted glass
Providing, fitting and fixing anodised aluminium partition walls of standard sections, joints mitred and welded (manufactured to relevant I.S. specification) and providing and fitting angle cleat, rubber gasket, bolting device screws etc. at all levels. (i)Partly 6mm thick glass panes and 12mm prelaminated ply board
Providing, fitting and fixing anodised aluminuim framed glazed doors with anodised aluminium frame made of 100mm x 45mm x 2.5mm section with door style of size 88mm x 45mm x 2.5mm, top rails 50mm x 45mm x 2mm lock rails 100mm x 45mm x 2mm and bottom rails 100mm x 45mm x 2.5mm fitted with glazing clip, special type rubber gasket complete including hydraulic floor spring, pivot, tower bolt in each leaf, aluminium door handle, lock, angles, cleat etc complete as specified and directed by the department at all levels. (iv) Prelaminated Board
Supplying, fitting, fixing anodised aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) a) Sliding door bolts (300mm x 16mm)
b) Tower bolt 250mm x 12mm
150mm x 10mm
c)Dooor/window handle 150mm
e)Door stopper with Rubber Stopper
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) b) Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX) (For Assam Type Bldg., drain works,,retaining wall&boundary wall etc. .
Supplying, fitting and fixing double leaf heavy duty iron gate, frame made from 40mm x 40mm x 6mm M.S. angle and with M.S. flat of 40mm x 6mm size as per approved design.Necessary locking arrangement for temporary closing the gate and 2nos.( minimum) strong iron hinges of M.S bars and flat of same sizes on each leaf to be embedded in C.C brick pillers as necessary including a red oxide painting to all iron works as directed and specified.(Separate payment will be made for posts).
Providing rails for plying of rollers of gate made made from 50mm x 6mm size M.S. flat and to be fitted with 3 nos of hinged hold fasts to be embedded in concrete prop. 1:2:4 of 10mm wide and 75 mm deep over brick flat soling 250mm wide including curing etc. complete.
Providing fitting and fixing vitreous water closet squatting pan (Indian type W.C Orissa pattern) of size 580 x 440 mm with 100 mm SCI 'P' or 'S' trap, 10 litre low level PVC flushing cistern with manually controlled device(handle lever) of Parryware/Hindware make with all fittings and fixtures complete including cutting and making good the walls and floors whereever required. (a) White
Providing fitting and fixing white vitreous china pedestal type water closet (European type W.C pan 400mm high ) of Parryware/Hindware make with seat and lead ,CP brass hinges and rubber buffers ,10 litre low level PVC flushing cistern with fittings, CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (a) White
Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) (i) Star Basin 550 x 400 (Cat. No.C0450)
Providing fitting and fixing Mirror of Agmeco make ( Cat. No. VN-9011) colour CP frame of complete as directed and specified.
Providing, fitting and fixing recessed soap tray of Hindware make complete as specified and directed.(A) White (ii) Size 150mm x 150mm (ii) Parryware make.
Providing, fitting and fixing chrome plated (CP) towel rail of Jaquar make complete as specified and directed.(a) Continental Accessories (600mm long)
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. (i) 160mm dia.
(ii) 110mm dia.
(iv) 75mm dia.
(v) 60 mm dia.
Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (ii) 110mm dia.
(iv) 75 mm dia.
Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (ii) 110mm dia.
(iv) 75mm dia.
Supplying fiting and fixing PVC coupler of (Supreme / Prince)or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. (a) In exposed surfaces or in trenches. (ii) 110mm dia.
(iv) 75mm dia.
Supplying fiting and fixing PVC reducer of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. (a) In exposed surfaces or in trenches. (iv) 110mm x 75 mm dia.
Supplying fiting and fixing PVC reducing Tee of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. (a) In exposed surfaces or in trenches. (iv) 110mm x 75 mm dia.
Providing fitting and fixing 75mm dia. PVC cowel of ISI make complete as directed and specified.
Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L. as directed and specified. (I) Exposed or in trenches 40 mm dia ii) Other ISI approved brand
(c) 32 mm dia ii) Other ISI approved brand
(d) 25 mm dia ii) Other ISI approved brand
(e) 20mm dia ii) Other ISI approved brand
(f) 15 mm dia ii) Other ISI approved brand
Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) (a) Essco make (Delux/ Sumthing spl./Tropical) (a) Bib cock short body
Supplying fitting and fixing chrome plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately) (I) Jaquar (i)15mm dia Male / Female (long thread)
Supplying fitting and fixing overhead adjustable Chrome Plated (C.P.) spray shower 15mm dia. of Sona make with wall flange as directed and specified.(pipes will be measured and paid separately) (a) Supreme shower with arm
Supplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed. (I) SONA make (a) Light type
Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes (III) 1000 litre capacity (b) Polycon make
Providing fitting & fixing laboratory sink of Parryware make with CI/MS brackets, C.P. brass chain with rubber plug, PVC waste pipe etc. complete including painting the fittings ,cutting &making good the walls wherever required. (Sink cock, stop cocks, waste coupling are to be paid separately.
Labour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department. iv) Bore hole of 150mm diameter
Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. (I) G.I. pipe a) TATA / SAIL (Medium) socket should be welded to the pipes. iv) 100mm diameter
Supplying fitting and fixing GI filter 2.00 metre long.
Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed. G.I. Pipe (a) TATA/ SAIL (medium) (sockets should be welded to the pipes) (iii) 40mm diameter
Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L. as directed and specified. (I) Exposed or in trenches b) 40 mm dia i) Using Tata (medium) From water tank to pump house(Inlet and at outlet
d) 25 mm dia i) Using Tata (medium)
f) 15 mm dia i) Using Tata (medium)
Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. b) 40 mm dia.
c) 25 mm dia.
Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table.
Construction of inspection pit inside measurement 450mm x450mm x450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm x450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed.
Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete Short point up to 3.00 metre. length.
Medium point up to 6.00 metre. Length.
Long point up to 10.00 metre. Length.
Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch ( Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) Long point up to 10.00 metre. Length.
Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt./ Havells make), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) Extra long point up to 15.00 metre. length.
Extra long point up to 20.00 metre. Length.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 2 x 10 sq. mm. + earth continuity with 1x 6 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. With 4 x 10 sq. mm. + earth continuity with 2x6 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for 5 pin 6 amp plug with 1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) including 5 pin 6 amp socket outlet (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) and 6 amp flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) earthing the 3rd pin of the socket as required on the switch board in surface/ recessed P.V.C. conduit wiring system. When fitted on same board of light and fan.
Supplying and fixing of Switch/Socket flush type (Anchor Penta PC CHERRY /Gold medal /Kolor kany.kom/Havells or equivalent make as approved by the Deptt.) on the existing PVC/ MS board including connection as approved by the Deptt.)complete as required
Supplying fitting and fixing of retrofit T-5 lamp in the existing luminaries. PHILIPS/ CROMPTON GREAVES/ WIPRO/ BAJAJ/ Havells/ HPL/ SOLAR make. T5 LAMP WITH BOTH END connection cable, as approved by the Deptt.TOR WITH BALLAST 28 W
Supplying and fixing of bulk head fitting suitable for CFL lamp complete with all accessories including 20 watts CFL lamp and connection as approved by the Deptt.)as required.
Supplying and fixing of Call bell ( Buzzer ) including 5/ 6 amp capacity button piano type bell push switch including connection as approved by the Deptt.)as required.
Supplying including fitting fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department [Without regulator]. Premium model 1400 mm Sweep. (ORIENT PSPO make) /Premium model 1400 mm Sweep SS-390 Deco. Havells make)
Supplying fitting and fixing of ceiling fan regulator including connections etc. complete as directed. Electronic Type
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. Domestic Ventil Air DB 300 mm sweep (Havells make)
Supplying with installation testing and commissioning of Hi -- wall 5 STAR rating non ducted split type air conditioner of the following capacity with cordless remote complete with copper pipe and electrical connection cable, as approved by the Deptt.)up to 5 m between the room unit and out door unit as directed by the department. 1.5 Ton Capacity Daikin make
VRF conditioner unit with protection and microfilter for 10 ton capacity
VRF conditioner unit with protection and microfilter for 5 ton capacity
Supplying with fitting and fixing Single Phase D.O.L Starter of the following specification complete including making necessary connection as approved, specified and directed by the deptt. Overload Relay Range 3.8 - 6.0 Amps for 2.2 KW
Supplying with fitting and fixing Voltage stabilizer of the following specification complete including making necessary connection as approved, specified and directed by the deptt. (SKYLAND / Vee-Dee / V GUARD / VERTEX/ INDO/ VENUS make) 4.0 KVA Automatic Input 90-280 V Out put 200-240 V
Supplying with fitting and fixing of Angle iron framing made 50 MMx50 MMx5 MM size angle iron for accommodation of 1.00 Ton to 2.00 Ton Window/split type A.C. Machine
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hager make) 12 way SPN double door
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof reversible Double door IP-43 double door surface mounting horizontal TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hager make) 4 way TPN (8+12) double door
6 way TPN (8+18) double door
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. B Series (Schneider MG, legrand, Hager make) 6 to 32A
Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. B Series (ABB, Schneider MG, legrand, Hager make) 40A
Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. B Series (Schneider MG, legrand, Hager make) 63A
Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 30mA sensitivity DP RCCB (ABB, Schneider MG, legrand, Hager make) 40A
Supplying with fitting and fixing panel mounting open execution 25KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 25 KA 415V 50 Hz 4P MCCB (Schneider, legrand, Siemens, Indo Asian make) 125A
Supplying with fitting and fixing Four Pole 415V Front handle operated On Load Change over switch (IP-20 protection powder painted sheet steel enclosure fitted on angle iron frame of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider, legrand, L&T make) 125A
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . 3 & 1/2 Core A2XFY 95.00 Sq. mm.3 & 1/2 Core armoured U.G. cable
Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) Core - 3 & 1/2 A2XWY A2XFY 25.00 Sq.mm 3&1/2 Core U.G. cable in 40mm dia medium duty G.I. pipe
95.00 Sq.mm 3&1/2 Core U.G. cable in 65mm dia medium duty hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.)
Supplying including installation, connection as approved by the Deptt., testing and commissioning of JET PUMP SET (HORIZONTAL) complete as directed and specified by the deptt. 1.5 HP Single Phase Motor jet pump set (Horizontal(Crompton Greaves/ Aquatic/ CRI/ V-Guard make) 2900 rpm with DOL Starter ( Crompton Greaves/ Control & Switch Gear/ BCH/ L& T / Siemens make) .
Supply, installation & testing of Copper Plate earth station with 600 mmx600 mmx3 mm copper earth plate with necessary 40 mm dia. G.I. medium duty watering pipe with G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mm C.I. hinged cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.
Supplying & laying of 8 SWG Copper. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
15 KVA On-Line UPS System (Orion or equivalent make as approved by the Deptt.) with PWM-IGBT technology 360V AC Input (300V – 470V A 3 Ph input- 1 Ph output With Isolation Transformer 12KW output with 0.8 output PF 60 min backup using SMF battery
Supplying including installation, testing and commissioning of Air/Water Cooled Diesel Generator set coupled to suitable alternator of 220/415 V, AC, 1/3-Phase 0.8 p.f.(la mounted on a 1) M.S. Fabricated base frame.,2) M.S. fuel tank of required capacity.,3) Residual Silencer.,4) Standard Control Panel.5) Suitable batteries with lead.,5) First fill of lube oil.,6) Acoustic Enclosure complete with all accessories as specified and directed by the department conforming to IS comprising the Technical Specification.. as per manufacturer. (RANGE FROM 5 KVA TO 625 KVA) Kirloskar green/bliss, Leyland, Volvo Penta, Perkinson, Mahindra, Greaves, Escort engine and Kirloskar, Stamford, Leroy somer alternator. 62.5 3 3980x1240x1680 1920 Kg A/C
Control Panel for Oxygen
Oxygen Manifold 4 + 4 cyl
Oxygen emergency system
Wall outlet for Oxygen
Copper pipe 12mm
Copper pipe 15mm
Isolation valve 15mm
BPC Flowmeter with pipeline adapter
Area alarm for O2
Oxygen pipe PVC 15mm
Vacuum pump 3 HP
Vacuum tank 500 ltr
Wall outlet for Vacuum
Copper pipe 22mm
Isolation valve 22mm
Ward vacuum unit
Supplying installation, testing, programming and commissioning of Audio equipment, 4 Channel Power Amplifier, 125 W per channel @ 8 ohms
Supplying installation, testing, programming and commissioning of Audio equipment, Rack‐mounted panel with four auto former to provide impedance matching between an amplifier output and constant voltage loud speakers
SITC of 2-Core 1.5 sq.mm Shielded FRLS Cable
Supplying installation, testing, programming and commissioning of Audio equipment, Gooseneck or equivalent as approved by the Depts. microphone - 30/ 50 cm hypercardiod/ Cardioids gooseneck (or equivalent as approved by the Deptt.) microphone without base
Supplying installation, testing, programming and commissioning of Audio equipment,4" Open‐Back Ceiling Speaker. 70V/100V taps at 6W, 3W, 1.5W (plus 0.75W at 70V), high 93 dB sense, 60 Hz to 18 kHz, for non‐plenum applications, 1.2 kg (2.5 l.
Supplying installation testing and commissioning of - 16 Chanel NVR (SAMSUNG or equivalent HONEYWELL/PANASONIC make)
Supplying installation testing and commissioning of Hard Disk For NVR 2 TB (SEAGATE / WD make)
Supplying installation testing and commissioning of 24 port L2 PoE Switch
Supplying installation testing and commissioning of IP Fixed mini Dome Camera: G5/X Series, video compression format: JPEG/MPEG- 4/H.264, codec streaming capability: Dual streaming (Any combination with JPEG/MPEG-4/H.264, including multiple streams of the same format), HD/Megapixel: Full HD, Maximum resolution: 2048X1536 (3 Meg, Vandal Resistant: IK10, Horizontal viewing angle: 86°, Optical zoom ratio: Fixed focal lens, Focal length: f=3.3, Imager: 1/2.8-type progressive scan Exmoor CMOS sensor, Minimum illumination: 2.3 lx (AGC 38 dB/50 IRE [IP]), Maximum frame rate: 30 fps H.264/MPEG-4/JPEG at 1280 x 720; 15 fps H.264/MPEG-4/JPEG at 1920 x 1080, Noise reduction: Yes, DEPA intelligence: Yes, Electrical D/N: day/Night, Power requirement: PoE (Class 1), Power consumption: 2.4 W max.
Supplying installation testing of UTP CAT6 Cable without PVC conduit
Supplying installation testing and commissioning of 1 KVA Numeric Digital 1000 HR Line Interactive UPS System along with battery Bank (2 Nos 100AH SMF for2 Hours backup )
APW Cyber Rack Server Rack 18U 600X1000mmD Server Rack with Front Glass Door and Rear Perforated Steel Door with Locks. "PDU 6*5/15A - 01 Nos. Fan 90 cfm 230V - 01 Nos. Mounting Hardware (Set of 10) - 1 Set 19"" 1U Cable Manager - 1 Nos. Support Stud - 4 Nos."
Supplying installation testing and commissioning of System for video management software: Microsoft Windows XP SP3/ Microsoft Windows Vista Enterprise/ Intel Core 2 Duo 2.0 GHz or higher, 4 GB RAM, 500 GB or higher SATA HDD, Gigabit LAN card, DVD Writer, 1024x768, 16/24 bit colour video card, 18.5” TFT monitor
Supply, Installation, Testing, Commission of Loop card for Addressable Panels make- MORLEY/FIRELITE/Apollo or equivalent as approved by the Deptt.)
Supply, Installation, Testing, Commission of Addressable Semi Flush Mounting Resettable (NonBreaking Glass) MCP, Supplied with Special Reset Tool BRAND : MORLEY/FIRELITE/Apollo or equivalent as approved by the Deptt.)
Supply, Installation, Testing, Commission of Intelligent Addressable Optical Detector with Remote Indicator Output With Base BRAND : MORLEY/FIRELITE/Apollo or equivalent as approved by the Deptt.)
Supply, Installation, Testing, Commission of Addressable Input / Ouput Module Brand : MORLEY/FIRELITE/Apollo or equivalent as approved by the Deptt.)
Supply, Installation, Testing, Commission of Addressable Loop Isolator Brand : MORLEY/FIRELITE/Apollo or equivalent as approved by the Deptt.)
Supply, installation, testing & commissioning of Addressable Hooter / SOUNDER; UL / LPCB approved, make - HONEYWELL, MORLEY IAS or equivalent as approved by the Deptt.)
Supply, installation, testing & commissioning of 1 Loop Intelligent / Analogue Addressable Fire Alarm Panel Microprocessor based character display Network option built in Alarm, Trouble & supervisory relays LPCB listed. make : HONEYWELL, MORLEY IAS or equivalent as approved by the Deptt.)
Supply, installation, testing & commissioning of Addressable Base Model - Detectors, LPCB approved, make - HONEYWELL, MORLEY IAS or equivalent as approved by the Deptt.)
Supply, installation, testing & commissioning of Control Module.UL / LPCB approved, make - Honeywell , MORLEY IAS or equivalent as approved by the Deptt.) with housing box Model:200e-SMD.
Supply & fixing of 2X1.5sq. mm. PVC insulated copper Armoured Cable on surface/ recess/ above false ceiling etc. as required. (ISI marked) )
Supplying, installation testing and commissioning of the following rating copper wound indoor / out door type transformer complete including the payment to be made to power supply authority for supervision charge, labour charge, cost of L.T/H.T metering etc. (excluding the cost of load security) and making necessary arrangement for charging approval of the sub-station from the competent authority as directed and specified by the department. Transformer should be as per CEA guidelines as ammended up to date upto 200 KVA star rating up to 5 star, above 200KVA as per CEA guidelines for losses along with LV enclosure. 160 KVA,50Hz.11/0.433 KV. Oil filled transformer with Off Circuit tap change.
Supplying and erection PSC pole 9.75 metre long, the pole is to be erection in 1:3:6 plain cement concrete foundation of size 1.50 m x 0.45 m x 0.45m having P.C.C base foundation 15 cm x 60 cm x 60cm including edge brick soiling and plastering above G.L. portion (0.30 metre complete with excavation of earth, handling of Surplus Soil, debris etc. to the proper place and refilling etc. as specified and as directed by the department
Supplying and erection of H.T. stay set complete (Galvanize with 19mm dia x1.8m long stay rod anchor plate of size 30cm x 30cm x6.4 mm thimble stay clamps tube buckle (19mmx 60c 7/3.15 mm dia G.I stay and strain insulation etc. in cement concrete 1:3:6:(1Cement:3Course sand:6graded stone aggregate 40mm nominal size foundation including excavation and refilling etc. as required and as directed by the department.
Supplying and erection of 11 KV Disc insulator (Poly) 45 KN with hard ware fittings etc. as required and as directed by the department.
Supplying and fitting fixing of galvanized channel of 75 mm x 40 mm x 65 x 2200 mm long complete with clamps ,blots, nuts etc. as required and as directed by the department
Supplying and fitting fixing of galvanized Angle of 50 mm x 50 mm x 60 x 5000 mm long complete with clamps ,blots, nuts etc. as required and as directed by the department.
Supplying and fitting fixing of 11 KV T Cross arm complete with clamps ,blots, nuts etc. as required and as directed by the department.
Supplying and erection of 11 KV Pin insulator (Poly) with G.I.pin, blots and nuts coach screw etc. as required and as directed by the department
Supplying and fixing of 11 KV 400 A Gang operated switch with all accessories complete as required and as directed by the department.
Supplying and fixing of 11 KV 150 A D.O. fuse set complete as required and as directed by the department
Supplying and fixing of 11 KV 5 KA Lighting arrestor (Poly) set complete as required and as directed by the department
Supplying including installation of 4' dia. C.I. earth pipe complete as required and as directed by the department.
Supplying and fitting fixing of H.T. danger plate complete as required and as directed by the department.
Supplying and string up AAAC Racoon conductor in the existing P.S.C./ M.S/ Galvanized pole with binding etc. as required and as directed by the department. Directed by the department.
Supplying with fitting and fixing panel mounting open execution 25 KA 415V 50Hz 3P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure) of the following capacity complete with making necessary connection as approved by the Deptt.),as specified and directed by the deptt. 25 KA 415V 50 Hz 3P MCCB (Havells, HPL, Indo Asian make) 125A
Modem
Metering cabinet
Fencing for sub station
Payment to be made to APDCL Authorithy as Load Security for
PRANJIT KUMAR NATH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .