Tender Value
₹1.1 Cr
EMD Value
₹2.1 L
Closing Date
12 Nov 2026, 3:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
SIG/NORTH
14 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less ;where V= Advertised value of the tender in crores of Rupees N=Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, asper the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information asper format-6, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s)during last 07 (seven) years, ending last day of month previous to the one in which tender is invited:(i)Three similar works each costing not less than the amount equal to30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender.
Defination of Similar Work :- Any signaling work involving outdoor work and / or addition and /or alteration in existing Indoor signaling system. OR any CLS or RI or EI or TPWS or IBS or ABS or BPAC work involving indoor and/or outdoor. Similar work to include indoor if the tendered work involves addition and / or alteration in existing indoor signaling system and outdoor if the tendered work involves outdoor work. OR Any such work involving activities as given in the name of the tendered work.
14 conditions · 5 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The tenderer shall clearly specify whether the tender is submitted on his own or on behalf of a partnership concern. If the tender is submitted on behalf of a partnership concern, he should submit the certified copy of partnership deed (PD) along with the tender and authorization to sign the tender documents on behalf of partnership firm. If these documents are not enclosed along with the tender documents, the tender will be treated as having been submitted by individual signing the tender documents. The tenderer whether sole proprietor, a limited company or a partnership firm if they want to act through agent or individual partners should submit along with the tender or at a later stage, a power of attorney(POA) duly stamped and authenticated by a Notary public or by Magistrate in favour of the specific person whether he or they be partners of the firm or any other person specifically authorizing him or them to submit the tender, sign the agreement ,receive money, witness measurement, sign Measurement Books, compromise, settle, relinquish any claims preferred by the firm and signed No claim certificate and refer all or any dispute to arbitration.
Tenderer should clearly state the status of firm and submit the relevant document in support of authentication, in absence of following/relevant documents the offer of tenderer is summarily rejected: (A)Self-declaration /proprietorship certificate in case of proprietor firm along with POA if any. (B) Partnership deed and power of attorney in case of partnership firm. (C)Certified copy of an extract of resolution passed by the board of directors in case of limited firm or Private Limited Company
(a) Sole Proprietorship Firm: (i)All documents in terms of Para 10 of the Tender Form (Second Sheet)of Tender document
(b) HUF: (i)A copy of notarized affidavit on Stamp Paper declaring that he who is submitting the tender on behalf of HUF is in the position of 'Karta' of Hindu Undivided Family (HUF) and 1.1.2 he has the authority, power and consent given by other members to act on behalf of HUF. (ii)All other documents in terms of Para10 of the Tender Form (Second Sheet)of Tender document
(c) Partnership Firm: (i)All documents as mentioned in para18 of the Tender Form document
(d) Company registered under Companies Act2013: (i)The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company (ii)A copy of Certificate of Incorporation(iii)A copy of Authorization/Power of Attorney 1.1.4 issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. (iv)All other documents in terms Para 10 of the Tender Form (Second Sheet) of Tender document
(e) LLP (Limited Liability Partnership): (i)A copy of LLP Agreement (ii)A copy of Certificate of Incorporation (iii)A copy of Power of Attorney/Authorization issued by the LLP in favour of the individual to sign the tender on behalf of the LLP and create liability against the LLP. (iv)An undertaking by all partners of the LLP that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from 1.1.5 participation intenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm/ LLP or JV in which they were/ are partners/members. Concealment /wrong information in regard to above shall make the contract liable for determination under Clause 62 of the Standard General Conditions of Contract.(v)All other documents in terms of Para 10 of the Tender Form(Second Sheet).
(f) Registered Society & Registered Trust: (i)A copy of Certificate of Registration (ii)A copy of Memorandum of Association of Society/Trust Deed (iii)A copy of Power of Attorney in favour of 1.1.6 the individual to sign the tender documents and create liability against the Society/Trust. (iv)A copy of Rules & Regulations of the Society (v)All other documents in terms of Para 10 of the Tender Form (Second Sheet) of tender document
Information as per Para 16 of GCC Part (1)(Tender form second sheet Annex-I) related to Employment/Partnership Etc. of Retired Railway Employees and Clauses 59 (9) & 62 (1) (xv) to GCC regarding employment etc. Of retired government officers by railway contractors
Certificate of Information regarding EMPLOYMENT/PARTNERSHIP etc. of Retired Railway Employees with the tender as per the attached proforma, Format 11 of tender document
Certificate of NO RELATIVE being an employee of Western Railway as per attached Performa Format10 of Tender document
Signalling work in connection with (1)Extension of High level Passenger platform at Nardana Paldhi under the section of ADEN/Amalner (2)Ukaisonghad-Jalgaon sec- Extension of PF.1 AN & PF 2 DXG with shelter hut covershed on PF (3)Amalner- Upgradation Development of station entry, PF surfacing work and extension of COP (PHASE-II) of Udhana-Jalgaon Section of Mumbai Division, Western Railway
SG_216_2_173_WA_PH53~WR
SG_216_2_173_WA_PH53
Open
Works - General
6 Months
Mumbai, Maharashtra
₹0
₹2.1 L
12 Oct 2026
12 Oct 2026
29 Oct 2026
341 items across 3 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 65,21,765.24 | ||
| — | 4.00 | — | — | ||
| SS Location box made of Spl Grade SS 304 of sizeas per drg.No.DRM/SG/948 (Single app.Case).The manufacturer's certificatein regard tograde ofstainless steel and test report besubmitted atthe time of supply. Note:-(1)Enclosure should bemade of 1.6 mm & door made of 2 mm thick SS304 sheet. (2)SS 20mm(rod) X 100 mm (height)male female hingesformoving door smoothly.(3)SS 16 mm Rodfixhandle for both the door.(4)SS sheet stiffner(0.8to 1 mm thickness) tostrengthen the doorbothside. (5) SS hook (6 mmrod) to be providedonboth doors for keepingthe door openposition.Stoppers to be providedfor both doors.(6)E-typelocking arrangement(W11) for bothdoor andlifting hook (5X150 mm)02 Nos (7) SSsheet 450mm x 650 mm for fulllocation boxprovision ofany writing work at frontside dooretc. (8)Provision of switch boardfor location lightfittedwith one two pin holder,One three pinsocket(female) and two pianotype switches of 6Aforlocation boxes withinternal wiring 2.5 sq.mmflexible copper wires,Holders ,socket and switch should be of ISImark. (9)Indian Railway property tag is to be provided on two side with following details, Sr. No,Manufacturing firm name& year of Manufacturing.(10)White enamel paintshall beprovided insidelocation box. (11)SSangle frame30 mm x 30mm x 5 mm is providedalong withlocation box. (12)Earth GI clamp 5 mmx 50 mmflat is providingto location at two endstoconnection earth GI patti. (13)All hardwareused inlocation box for mountingarrangementsshall be ofSS (nuts, bolts, washersetc).(14)Suitable locationbox Hylam fabricationtoprovide the clear space ofwriting to 18 cm to20 cm(15) Packing eachlocation box tobeshipped using wrapping plastic sheet around location box. | — | — | — | 2,39,423.92 | |
| — | 4.00 | — | — | ||
| SS Location box is made of Spl Grade SS 304 of sizeas per drg. No.DRM/SG/945 (Half app.Case).Manufacturer'scertificate in regard tograde ofstainless steeland test report shall besubmittedat the time ofsupply. Note:-(1)Enclosedshould bemade of 1.6mm & door made of 2mm thick SS304 sheet.(2)SS 20 mm (rod) X 100mm (height)male femalehinges for moving doorsmoothly.(3)SS 16 mmRod fix handle for boththe door.(4)SS sheet stiffner (0.8 to 1 mm thickness) for strengthenthe door both side. (5) SShook (6 mmrod) to beprovided on both doorsfor keeping thedoor openposition. Stoppers to beprovided forboth doors.(6)E-type lockingarrangement (W11)forboth door and lifting hook(5X150 mm) 02 Nos(7)SS sheet 250 mm x 450mm for half locationboxprovision of any writingwork at front sidedooretc. (8) Provision ofswitch board forlocationlight fitted with one twopin holder, Onethree pinsocket (female) and twopiano typeswitches of 6Afor location boxes withinternalwiring 2.5 sq.mm flexible copper wires,Holders,socket andswitch should be of ISImark.(9)Indian Railwayproperty tag is providedon twoside with followingdetails, Sr. No, Manufacturingfirm name& year of Manufacturing. (10)Whiteenamel paintshall be provided insidelocation box.(11)SSangle frame 30 mm x 30mm x 5 mm isprovidedalong with location box.(12)Earth GIclamp 5 mmx 50 mm flat is providingto locationat two ends toconnection earth GI patti.(13)Allhardware used inlocation box formountingarrangements shall be ofSS (nuts,bolts, washersetc). (14)Suitable location box Hylam fabrication toprovide the clear space of writing to 18 cm to 20cm. (15) Packing each location box to beshipped usingwrappingplastic sheet around location box. | — | — | — | 2,07,992 | |
| — | 4.00 | — | — | ||
| Excavation and Casting of Apparatus Case foundation with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc. for Casting of foundation will have to be brought by the contractor at his own cost. Single Case as per Drg No SK 748 or CSTE/5074 or SSLocation | — | — | — | 28,650.52 | |
| — | 4.00 | — | — | ||
| Excavation and Casting of Apparatus Case foundation with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc. for Casting of foundation will have to be brought by the contractor at his own cost. Half Case as per Drg No SK 747or CSTE/5074 or SSLocation. | — | — | — | 21,951.44 | |
| — | 4.00 | — | — | ||
| Installation of Apparatus Cases with miniature 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand. 'E' Type lock will be provided by Railway. Single Case | — | — | — | 4,305.16 | |
| — | 4.00 | — | — | ||
| Installation of Apparatus Cases with miniature 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand. 'E' Type lock will be provided by Railway. Half Case | — | — | — | 2,628.6 | |
| — | 4.00 | — | — | ||
| IS 13410: Glass Reinforced Polyester Sheet Moulding Compounds (SMC) Size of Sheet : 1000x1000x8. | — | — | — | 21,554.68 | |
| — | 4.00 | — | — | ||
| Phenolic laminated Sheet,grade P3 in standard size of1220 X 1220 x 10 mm as perspec. No IS 2036 of 1995 orlatest. Test report ofmanufacture to be supplied. | — | — | — | 17,771.72 | |
| — | 4.00 | — | — | ||
| Fabrication and fixing of SMC sheet in location box by providing all fixtures as per Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per Drg and arrangement similar to SK 783- 1/2. With latest alterations & as per instructions of Rly engineer at site.Note: SMC sheet will be taken in place of phenolic laminated sheet. Single Case | — | — | — | 9,781.44 | |
| — | 4.00 | — | — | ||
| Fabrication and fixing of SMC sheet in location box by providing all fixtures as per Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per Drg and arrangement similar to SK 783- 1/2. With latest alterations & as per instructions of Rly engineer at site.Note: SMC sheet will be taken in place of phenolic laminated sheet. Half Case | — | — | — | 3,111.12 | |
| — | 8.00 | — | — | ||
| Preparation and fixing of location box board on 03 mm ACP sheet with size 12 x 18 size A3 for location box including pasting of printed/ painted vinyl sheet and lamination (printing/painting of location detail on vinyl sheet covered in schedule item separately). | — | — | — | 1,917.84 | |
| — | 4.00 | — | — | ||
| Lettering / Numbering Termination particulars, equipments names etc., legibly and neatly inside location boxes. This includes supply of paints of Asian Paints/ Nerolac / Dulux / Berger make. Full Case. | — | — | — | 517.04 | |
| — | 4.00 | — | — | ||
| Lettering / Numbering Termination particulars, equipments names etc., legibly and neatly inside location boxes. This includes supply of paints of Asian Paints/ Nerolac / Dulux / Berger make. Half Case. | — | — | — | 352.72 | |
| — | 75.00 | — | — | ||
| Transferring of Signaling/Telecom cables from existing Location box to New Location box . The work include breaking/ Dismantling of Existing foundation of locations, excavating and removing / segregating coils of 2C/6C/12C/19C/24C/30C/Quad cables which may be about 10 mtrs. in length. These cables are to be disconnected and removed from the existing location one by one as per the instruction and under the supervision of Railway staff present at site. The cable is then to be inserted and terminated in new location box. The item includes neatly dressing of cable, making wiring tree etc.The material required to dressing /lacing will be arrange by contactor. The work is required to be done systematically and with due precaution during the block or disconnection within the time that may be allowed. The excavation work to be done carefully without damaging the cable to avoid undue failure. (Termination charges will be given separately). Note: Proportionate payment will be made if cable of other length. One No unit = One cable of 10 m length) | — | — | — | 22,350 | |
| — | 4.00 | — | — | ||
| Shifting of existing full location boxes coming in the alignment of new line. The work includes losing & removal of soil around location boxes by excavating soil around foundation, making of pit for shifting of location box horizontally opposite to railway track up to 0.5 to 1.0 mtr. This includes loosing of existing cable coils without any damage. The excavated soil shall be back filled after shifting of Location Boxes. Location box shall be shifted by push method with the help of jacks or by crane by contractors own expenditure under instructions of engineer in-charge at site. The work may affect train working hence the work shall be done as per margin only or during traffic block only. | — | — | — | 17,479.72 | |
| — | 4.00 | — | — | ||
| Shifting of existing half location boxes coming in the alignment of new line. The work includes losing & removal of soil around location boxes by excavating soil around foundation, making of pit for shifting of location box horizontally opposite to railway This includes loosing of existing cable coils without any damage. The excavated soil shall be back filled after shifting of Location Boxes. Location box shall be shifted by push method with the help of jacks or by crane by contractors own expenditure under instructions of engineer in-charge at site. The work may affect train working hence the work shall be done as per margin only or during traffic block only. | — | — | — | 13,518.88 | |
| — | 2400.00 | — | — | ||
| ARA Terminal blocks with links made of PBT Spec No.s/75/2006 (Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4. | — | — | — | 1,80,000 | |
| — | 2400.00 | — | — | ||
| Fixing of ARA Terminals /Screw less connectors and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry. | — | — | — | 54,600 | |
| — | 2400.00 | — | — | ||
| Providing Ferrules of cabletermination as per latest policyissued by HQ. The work to be donewithout disturbing existingconnections. Contractors willprovide ferrules as per colour codeand nomen clature given byEngineer incharge. As far aspossible self locking type ferrulesto be provided. Type / design offerrules may be approved fromrailway before supply. | — | — | — | 10,392 | |
| — | 2400.00 | — | — | ||
| Termination of outdoor cables, main cables laid in location boxes, Cable termination rack etc. at both ends on ARA terminal or on 8 way terminals or on screw less connectors. Both ends of a cable core terminated shall be counted as one terminal. This includes all associated works of pulling out the cable from underground, peeling off insulation, dressing of cable core supported on sting rod with contractor's own material. The work shall be done as per instructions of Rly engineer at site. | — | — | — | 56,880 | |
| — | 8.00 | — | — | ||
| Pad locks Godrej make, Hardened NavTal 7 lever, 65mm Dia with common key or similar product having same feature & technical data. | — | — | — | 1,574.32 | |
| — | 8.00 | — | — | ||
| Miniature 'E' type lock complete with keys as per RDSO Drg. No. SA 3473, 3373 & spec. IRS(S) 30/64. Ward to be specified by Engineer - in - charge. | — | — | — | 16,652.16 | |
| — | 8.00 | — | — | ||
| Maintenance Free Earth Electrode of length3m, including supply of 3 bags of Earthenhancementmaterial for earthling(10KGs/bag) for each electrode & otheraccessories as per Drg. No. SDO / RDSO/E&B/001 andRDSO Spec No. RDSO /SPN/197/2008. This item includes thefollowing items: (a) Copper bonded steelearth electrodeof 3.0 meter long & 17.2 mmdia with Cu- bonding thickness of min 250micron - 1 no. (b) Earth-enhancingcompound(10 Kg/Bag) - 3 No. (c) Cu- strip 200 X 25 X 6 mm to terminate earth rod =1no. (d) Cu-strip 300 X 25 X 6 mm(MEEB)= 1 no. (e) Cu-strip 150 X 25 X 6mm (SEEB) = 1 no. | — | — | — | 83,224 | |
| — | 8.00 | — | — | ||
| Installation of Maintenance Free Earth Electrode for Maintenance Free Earth spec of RDSO/SPN/197/2008. | — | — | — | 11,654.32 | |
| — | 8.00 | — | — | ||
| Supply of Fiber/ SMC/FRP/RCCEarthChamber as perinstructions of EngineerIncharge as per siterequirementas perSTS/E/TAN/3006 ver 3.0 | — | — | — | 5,192 | |
| — | 40.00 | — | — | ||
| Providing brick masonry in ratio 1:6 cement and mortar including plastering with 1:4 cement and sand mixture both sides, 20 mm thick each with contractor's owned class II bricks, including excavation, curing, grouting, bolting etc. wherever required. Bricks sand and cement to be supplied by the contractor. | — | — | — | 82,454.4 | |
| — | 40.00 | — | — | ||
| Cement concrete work for miscellaneous items in the ratio 1: 3: 6. Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm.) (Aggregate cement & sand to be supplied by the contractor). | — | — | — | 2,50,360 | |
| — | 6.00 | — | — | ||
| Dismantling / Releasing of existing Signaling Gears. One Signalling gear will be all parts of one signal (consisting of CLS unit, Signal post along with base) or lever frame (5 levers set), or one point (consisting of all parts of a mechanical point, point machine, ground connections etc.) or one track circuits (consisting of battery box & other parts of DC Track circuit / AFTC /DAC) or one Block instruments or One Lifting Barrier or One Location Box etc. .This includes the cost of transportation of release materials to store depot or as decided by consignee in charge. This work to be done by contactors with his own vehicle and labour. (Per unit means Per Gear). | — | — | — | 6,376.92 | |
| — | 6.00 | — | — | ||
| Dismantling of Concrete foundation/ DemolishingRCC/CC/Stone work /CuttingTar/ carpentering/ CC Flooring/Precast concrete slab/ Brick work including leading the debrisinside Railway limit or outsideRailway limit as directed by site in charge. This work to be done by contactors with his own vehicle and labour. | — | — | — | 3,632.46 | |
| — | 1200.00 | — | — | ||
| Supply Polyolefin cable channel of size width 240/340 mm, height 155/230 internal/external, length 1meter produced of polyolefin with fire protection class K-1 in accordance with DIN 53438 Part-II for laying signaling/telecom cables, channel attachable to each other with male female swallow tail connectors and having a suitable detachable cover, as per RDSO STS/E/cable laying Practise Vol-IV and as per technical specifications. | — | — | — | 20,21,400 | |
| — | 600.00 | — | — | ||
| Half Round RCC pipes & collars of 150 mm internal dia (1 meter long) along with collars as per IS No. 458/2003 of NP type. Tenderer shall submit inspection/test report before supply for prior approval by Engineer in charge. | — | — | — | 94,800 | |
| — | 650.00 | — | — | ||
| Excavation of cable trench as per cable route plan, 1 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr wide advised by Engineer-in-charge alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc., covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on Western Railway and instructions of Railway Engineer at site. In case 1m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1m. | — | — | — | 5,45,350 | |
| — | 30.00 | — | — | ||
| Digging of trench 1.2 M deep from rail flange/ road level and, 0.3 Mtr to 0.6 Mtr wide and back filling after placing of DWC/ RCC/GI pipe. (Placing of DWC/RCC/GI pipe covered separately).The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. For track crossing, Drg. No.CSTE/3644 Pg.7 of 11 and for Road Crossing, Drg. No. CSTE/3644 Pg. 5 of 11 are to be followed. | — | — | — | 26,217.9 | |
| — | 20.00 | — | — | ||
| Digging of cable trench 0.3 Mtr. Deep and 0.3 Mtr. Wide on Asphalted Platform / Road / Hard rocky area. Refilling with earth leveling of trenches & restoring the original surface of trenches. | — | — | — | 10,255.2 | |
| — | 20.00 | — | — | ||
| Cutting of Hard rock in trenches /Preparation of cable way/Chase 150mm wide at the bottom and 300 mm deep in hard rock (Drg prepared by contactor & approved by Engineer In charge) for laying of S&T cables where minimum required depth not possible & which is verified and agreed by Engineer In charge of the work or his representative shall be made as per Drg. No RE/S&T/ALD/SK/301/85. Refilling of the same with concrete mixture of 1:3:6 from top of the cable way/ chase. Payment of concrete will be made separately through a separate item in the schedule of work. | — | — | — | 8,774.6 | |
| — | 200.00 | — | — | ||
| Horizontal direction drilling/boring without damage of surface road using Auger Machine. The bore shall be 150 mm Dia & shall be done at the depth of minimum 1200 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. The length of the bore shall be minimum 4 Mtr long. The HDD with or without HDPE pipe as per direction of Engineer In charge.Note: HDPE pipe supply is taken as separate item. This item also includes cable laying (HDD boring). | — | — | — | 2,37,570 | |
| — | 200.00 | — | — | ||
| High density polyethylene pipes (HDPE) of 110 mm/125 mm outer Dia, 10 mm wall thickness, along with one coupler for every 6 Mtr. As per spec. No. Is 4984:2016 with latest amendments and material grade: PE 80. | — | — | — | 1,40,200 | |
| — | 1.00 | — | — | ||
| Digging of cable pit (min2x2x1m) as per instruction of Site Engineer, supplying and filling of sand before and after coiling the cables, covering top of the cable pit with stones and providing brick masonry on all four sides of the cable pit and plastering there after. | — | — | — | 12,567.83 | |
| — | 10.00 | — | — | ||
| Double Walled Corrugated(DWC) HDPE Pipe with associated collars etc. as per RDSO Specification No.RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and non flame propagating type in 6 meters straight lengthand of size120 mm outer die,& 103.5mm innerdia. (Themanufacturers, suppliersmust producevalid IS licenseand should be certified underISO9000 and shall submitcopy of certificate). Oneofthe following couplingarrangements should alsobesupplied with each pipe asper the siterequirement. 1)Suitable snap fit couplerwithrubber 'O-Ring 2) Spacers 3)Tees 4) Bend,5) End-cap(The total quantity of aboveitems isequal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vender name and year of manufacture can be easily identified. | — | — | — | 19,122 | |
| — | 660.00 | — | — | ||
| Placing of DWC/RCC pipes along with collars in trenches at places of track and road crossings, platform cuttings etc. also for straight cable laying. (Cable laying is covered separately.) | — | — | — | 21,925.2 | |
| — | 20.00 | — | — | ||
| Medium Class G.I. Pipes to IS: 1239 (Pt.)-2004 or latest; 100mm dia. (int. Dia) 3.65 mm thick or above with coupling. G.I. pipes shall have ISI mark on it and contractor should submit manufacturer's test certificate of G.I. pipes. | — | — | — | 23,405.6 | |
| — | 20.00 | — | — | ||
| Laying and fixing of Medium class GI pipes 100 mm Dia (4.5 mm thickness) as per IS 1239 ( Part 1) 2004 or latest with coupling on culverts/bridges, perforated at a distance of 20 cm or less with 10 mm Dia hole, or at any other locations as decided by Site Engineer. The GI pipe is to be filled with chattered compound. It includes supply of all material required for fi Xing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends. The e laying and fi Xing to be done as per RDSO drawings No. SDO/cable laying/011 and SDO/cable laying/012, issued vide RDSO document No. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014, or latest. | — | — | — | 8,360 | |
| — | 26000.00 | — | — | ||
| Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trucking. This also includes laying of cables in track crossings & road crossings. Item includes provision of labels of colored plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each G.P.(Cables will be daggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes. | — | — | — | 2,43,620 | |
| — | 20.00 | — | — | ||
| Supply and installation of RCC cable route marker engraved and painted on both side along the route every 50mm and route diversion as per Drg. No 4014/00/CC4 or latest/ Stone marker. | — | — | — | 8,253.2 | |
| — | 4.00 | — | — | ||
| Supply of Signalling Rapid Joint UV resistance cable jointing system with two half separated enclosure tapered at both ends filled with cross linked polymer and highly robust insulating plastic case class -2 joint . The joint shall be as per RDSO draft specs no. RDSO/SPN/TC/101/2012, the jointing kit suitable for signalling cable Size 6 x 1.5, 12 x 1.5, 19 x 1.5 , 30 x 1.5 mm2.Note: The joint made by rapid jointing kit for signalling cable will be temporary. | — | — | — | 44,800 | |
| — | 60.00 | — | — | ||
| Maintenance of Track mounted equipments like S&T fitting on turn outs including different activities during BCM/TTM/TRR works as follows:- Specially opening and refixing of DC-TC jumpers/AFTC jumpers / Axle counter, transducers during different Engg. works Opening of DC-TC /AFTC jumpers /axle counter transducers digging work from rail to TLJB /TMU /0 bond /location is required to be done as per site requirement also after refixing of DC-TC /AFTC jumpers /Axle counter transducers needs to be buried in proper depth. It includes drilling hole in rail as per site requirement. The team to be provided for this work should comprise of : Fitter- 1 Nos., Blacksmith 1 Nos. Mason/Carpenter- 1 No. and Helpers-5 Nos. also it include any work of EOLB or sliding boom and earthing arrangement of Signalling gears. Any other work as per instruction of Railway Engineer. All T&P & Jigs required to execute the work will be supplied by the contractor.(Per Day means Job) | — | — | — | 4,06,546.8 | |
| — | 1.00 | — | — | ||
| Single core multi-strand wire 0.5 sq.mm. (16 conductor each dia. 0.2mm), as per IRS 76/89 (Amd3) or latest. | — | — | — | 5,548.54 | |
| — | 2000.00 | — | — | ||
| Disconnect Terminal Block, Screw less type, 4-wire front entry (Two in-put & Two out- put) The color will be decided by Engineer - in - Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3). as per RDSO Spec. No. RDSO/SPN/189/2004. With latest amendments.Note: Make to be approved by Railway before supply. | — | — | — | 1,17,060 | |
| — | 500.00 | — | — | ||
| Supply of End plate 2.5mm/0.091 in thick as per site requirement. | — | — | — | 5,535 | |
| — | 1000.00 | — | — | ||
| Supply of End Stopper 10mm/0.0394 in width as per site requirement. | — | — | — | 10,860 | |
| — | 32.00 | — | — | ||
| Supply of Carrier Rails for above 35mm x 7.5mm, 1mm/0.039 in thickness un-slotted type as per site requirement. | — | — | — | 3,644.16 | |
| — | 2000.00 | — | — | ||
| Fixing of ARA Terminals /Screw less connectors and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry. | — | — | — | 45,500 | |
| — | 2000.00 | — | — | ||
| Providing Ferrules of cabletermination as per latest policyissued by HQ. The work to be donewithout disturbing existingconnections. Contractors willprovide ferrules as per colour codeand nomen clature given byEngineer incharge. As far aspossible self locking type ferrulesto be provided. Type / design offerrules may be approved fromrailway before supply. | — | — | — | 8,660 | |
| — | 2000.00 | — | — | ||
| Termination of outdoor cables, main cables laid in location boxes, Cable termination rack etc. at both ends on ARA terminal or on 8 way terminals or on screw less connectors. Both ends of a cable core terminated shall be counted as one terminal. This includes all associated works of pulling out the cable from underground, peeling off insulation, dressing of cable core supported on sting rod with contractor's own material. The work shall be done as per instructions of Rly engineer at site. | — | — | — | 47,400 | |
| — | 2.00 | — | — | ||
| Supply of final Cable Route Plan as per laid cable duly measured at every 30m clearly indicating distance of laid cable from fixed point of reference & indicating all track crossings and tail cables in original tracing along with Auto CAD in Pen Drive and Six set copies after approval. | — | — | — | 3,160 | |
| — | 2.00 | — | — | ||
| Design and supply of cable courage plan, location particulars, Cable termination rack particulars, cable meggeringreport, earth resistance particulars, Traction bonding diagram, 1/2 wire count sheet and any other drawing in AutoCAD inA3/A4 size. The contractor shall initially supply 3 sets of circuits complete for approval of Railways. Railways will return one set to the contractor duly approved with alterations/corrections, if any. The contractor shall incorporate Railway's alterations/corrections in the tracings without any deviation and submit all tracings complete in all respects to the Railways along with PENDRIVE & 4 sets of final approved drawings. This includes designing of cable coreage plan based upon I.P in consultation with engineer-in-charge For small/medium yards.Station | — | — | — | 1,27,396 | |
| — | 2.00 | — | — | ||
| Design of Cable Route Plan submission of Three paper copies for approval. | — | — | — | 19,746 | |
| — | 2.00 | — | — | ||
| Lettering & Numbering of detailand description writing of on relayrack, relays, cable terminationrack, battery &power equipments,IPS,operating panel, axle counteretc.constituting entire system withcontractor's own paint and writingmaterial. The work shall be done asper extant practice on W.R Rly &instruction of Rlyengineer at site. | — | — | — | 7,902 | |
| — | 2.00 | — | — | ||
| Provision of 10" Data input system of reputed make as decided by Engineer incharge | — | — | — | 59,400 | |
| — | 1.00 | — | — | ||
| Diagnostic Terminal :Multisection Portable operator console for onsiteprogramming of AxleCounters as per technical requirement | — | — | — | 91,401 | |
| — | 9.00 | — | — | ||
| Track feed battery chargers, 110V AC input, 2 to 6/10 V DC Output; as per Specn.No.IRS.S 89/ 2013 with latest amendments. Charger shall be suitable for charging 80 AH battery. | — | — | — | 31,709.43 | |
| — | 9.00 | — | — | ||
| Choke Coil for Single Rail Track Circuit on 25 KV 50 Hz AC Electrified Section as per Spec No IRS S 65/1983 with latest amendments. | — | — | — | 19,165.77 | |
| — | 27.00 | — | — | ||
| Low maintenance Lead acid secondary cell 2V/80 AH (Track feed Battery), shelf mounting type conforming to IRS:S- 88/2004 or latest (uncharged). | — | — | — | 59,772.87 | |
| — | 9.00 | — | — | ||
| Adjustable Track Feed Resistance disc type 30 ohms as per RDSO Drg. No. SA 20166/M (Adv.) with latest amendments (with Phenolic molded base). | — | — | — | 8,806.14 | |
| — | 9.00 | — | — | ||
| Fixing and wiring of DC track circuit equipments i.e. track feed charger, resistance, track relay, battery, PPTC fuses etc., in the Apparatus Case and battery box as per standard practice. Termination of tail cable on M 6 / Screw less terminals WAGO or FINOLEX or similar approved make terminals/ fuse blocks / HRC fuse. Item includes testing / commissioning of track circuit. Complete wiring material (including PPTC fuses) which are not covered in Schedule will be supplied by contractor. (Supply of Track feed battery charger, track feed battery, resistances & 'B' type choke & Track relays will be supplied by Railways / covered in Schedule separately). | — | — | — | 60,003 | |
| — | 9.00 | — | — | ||
| Installation of DC track circuits covering points zones also. The item includes provision of continuity bonds of seven strand PVC jacketed wire/ GI wire 8 SWG on rail joints after drilling bond-hole of 7.0/7.1/7.2mm Dia (double bond with sleeves and rail clips are to be provided at each rail joint), insertion of insulated block joint, fixing of Track lead Junction box on MS angle two numbers of size 40X40X5 mm 1200 mm length for track feed/ jumper / track relay ends of track CCTs (as per double TLJB arrangements) and also for fixing jumper cables as per insulation diagram WR Drg No. CSTE/6055 and standard practice, making rail connections through suitable insulated sleeves from Track lead Junction box at TF, jumper & TR end with seven strand PVC jacketed wire /GI wire 8 SWG, rail clips for fixing bond wire on the TLJB as per standard practice, termination of tail cables on bootleg terminals etc. TF/TR wiring shall be fixed on the suitable arrangement on PRC sleepers with the help of hooks. Hooks shall be provided on PRC sleepers with the help of suitable steel bracket. This item also includes fixing & supply of channel pins etc. The item also includes supply of MS angles/ trestles, GI wire 8 SWG / seven strand PVC jacketed wire, hooks, rail clips etc | — | — | — | 65,958.48 | |
| — | 36.00 | — | — | ||
| Track Lead Junction Boxes as per C.Rly Drg. No.RST 11509 made from fiber glass/SMC/FRP along with terminal blocks. | — | — | — | 40,343.4 | |
| — | 100.00 | — | — | ||
| GI wire 8 SWG (4mm Dia) suitable for track circuit rail bonding. | — | — | — | 6,817 | |
| — | 6.04 | — | — | ||
| Channel Pins MS (Galvanized) single groove, 7 mm suitable for 4mm Dia bonding wire as per spec No IRS S 17 & RDSO Drg No. S-69/M. | — | — | — | 6,040 | |
| — | 27.00 | — | — | ||
| Charging of Lead Acid Batteries (2V 80AH) with contractors' own battery grade sulphuric acid and distilled water with a minimum of two charge-discharge cycles, installation of charged batteries in groups & their connection & wiring. The work shall be done as per the extant practice of W.Rly & instruction of the Engineer-in-charge. Detailed measurements of initial charging shall be recorded jointly by the contractor & Rly's site-in-charge. | — | — | — | 10,154.7 | |
| — | 100.00 | — | — | ||
| Provision of bonding with GI wire 4mm Dia (8 SWG) for track jumper & fish plate joints bonds. This will include drilling of 7.0/7.1/7.2 mm Dia holes in rails (4 Nos.) and provision of two jumpers for each bond, clipping of bonds etc. with contractors own tools as per instruction of Rly. Engineer at site. | — | — | — | 18,547 | |
| — | 36.00 | — | — | ||
| — | 2.00 | — | — | ||
| — | 9.00 | — | — | ||
| — | — | — | 48,792.6 | ||
| — | 9.00 | — | — | ||
| — | — | — | 43,910.1 | ||
| — | 24.00 | — | — | ||
| — | — | — | 1,29,448.32 | ||
| — | 81.00 | — | — | ||
| — | — | — | 10,482.21 | ||
| — | 54.00 | — | — | ||
| — | — | — | 562.68 | ||
| — | 9.00 | — | — | ||
| — | — | — | 635.04 | ||
| — | 81.00 | — | — | ||
| Round head type non deteriorating type low voltage cartridge fuse as per Spec No IRS/S/78/92 with latest amendments 2A/4A/6A capacity. | — | — | — | 4,634.01 | |
| — | 2.00 | — | — | ||
| Portable Handheld Electronic Labeller with 05 nos. of tape cassette having following or better specifications:1) Print Resolution: 180 dpi,64 dots2) Print Speed: 20mm/sec3) No. of Lines Printable: 2 Lines4) Tape Cassette: 12mm 5) AC Adapter with rechargeable alkaline batteries.6) Accepted make: Brother/Epson/Casio onlyTenderer should submit make and model of the item for which the offer is being quoted | — | — | — | 1,02,650 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .