Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.8 LAccepted-AOC 00 KIWADI SAFEDABAD BARABANKI BARABANKI UTTAR PRADESH 225001 | BARABANKI | UTTAR PRADESH | 225001 | L1 | Accepted-AOC L1 bidder is techno commercially qualified. | |
| 2 | Rejected-Technical AT DHORI STAFF QTR PO DHORI DIST BOKARO JHARKHAND | BOKARO | JHARKHAND | 825102 | - | Rejected-Technical Submitted annexure-II is not as per NIT | |
| 3 | Rejected-Technical AT KARGALI BAZAR BERMO DIST BOKARO PIN NO 829104 JHARKHAND | BOKARO | JHARKHAND | 829104 | - | Rejected-Technical Submitted annexure-II is not as per NIT |
Tender Value
₹18.3 L
EMD Value
₹23,000
Closing Date
7 Apr 2025, 10:00 amClosed
S.O.(EnM)
Office of the General Manager, dhori, Po- Dhori , pin-825102
(A) Maintenance of 440 volt near G.M. office substation to C-32 under G.M. unit, Dhori Area (B) Repair and maintenance of 440V OH line DAV ground and CISF ground and Durga Mandap Ground at Central colony under CCD, G.M. unit, Dhori Area.
2025_CCL_333307_1
GM(D)/SO(EnM)/DA/24-25/80
Open Tender
Electrical and Maintenance Works
Item Wise
10 days
GM unit, dhori
please refer tender documents
2 documents required · 2 mandatory
₹23,000
21 Jun 2025
26 Mar 2025
8 Apr 2025
27 Mar 2025
7 Apr 2025
27 Mar 2025
27 Mar 2025 - 3 Apr 2025
Amount
Part A: Maintenance of 440 volt near G.M. office substation to C-32
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and re-filling etc. as required : Above 6.50 Mtrs. & upto 8.00 mtrs.
Erection of ACSR conductor of 7/2.11mm to 7/3.00mm diameter including binding etc as required.
Supplying and erection of 75 mm x 90 mm shackle insulator with G.I. bolts, nuts and straps etc. as required.
Supplying and erection of 100 mm x 65 mm pin insulator with G.I. spindle and nuts etc. as required.
Supplying and erection of stay set complete (galvanised) with 19/20 mm dia x 1.8 metres long stay rod, anchor plate of size 45 cm x 45 cm x 7.5 mm, thimble, stay clamps, bow tightener, 7/3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
Supplying of channel iron 75 mm x 40 mm x 6 mm (7.14 kg per metre) cross arm for 2 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with and finished paint as required.
Supplying of channel iron 75 mm x 40 mm x 6 mm (7.14 kg per metre) cross arm for 4 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required.
Erection of angle iron/ channel iron cross arm on wood/RCC/PCC/ steel tubular/ rail pole etc. as required.
G.I. wire 8 SWG
Erection of G.I. wire no. 8 SWG including binding etc. as required.
Erection of cradle guard as required.
Dismantling of pole/street light standard/strut embedded in cement concrete foundation etc. as required.
Dismantling of overhead lines comprising of copper/aluminium overhead conductor, G.I. wire cross arms, insulators etc. as required.
Applying priming coat : With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanized iron/steel works (+) With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat)
Painting with aluminium paint of approved brand and manufacture to give an even shade : Two or more coats on new work.
Transporting of pole.
Part B: DAV ground and CISF ground and Durga Mandap Ground
Supply of cement pole.
Erection of RCC/PCC pole of following length in brick ballast and ramming the foundation, finishing with 150 mm thick cement concrete (1:3:6) layer on top with including excavation and re-filling etc. as required. : Above 8.0 metre and upto 11.0 metre
Erection of steel tubular pole in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling and secured with holding clamps, bolts, nuts etc as required
Transportation of pole
Erection of all aluminium conductor of 7/1.96 mm to 7/3.10 mm diameter including binding etc. as required.
Supplying and erection of 100 mm X 110 mm shackle insulator with G. I. Bolt, nuts and straps etc. as required.
Supplying and erection of 100 mm X 80 mm pin insulator complete with G. I. Spindle and nuts etc. as required
Supplying of channel iron 75 mm x 40 mm x 6 mm (7.14 kg per metre) cross arm for 4 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required.
Supplying of channel iron 75 mm x 40 mm x 6 mm (7.14 kg per metre) cross arm for 2 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with and finished paint as required.
Erection of angle iron/ channel iron cross arm on RCC and steel tubular pole as required.
Supplying and erection of stay set complete (galvanised) with 19/20 mm dia x 1.8 metres long stay rod, anchor plate of size 45 cm x 45 cm x 7.5 mm, thimble, stay clamps, turn buckle (20 mm x 60 cm), 7/4.00 mm dia G.I. stay wire and strain wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
Providing of 8 SWG G.I. wire
Erection of G.I. wire including binding etc. as required.
Erection of cradle guard as required.
providing and making steel pole collar with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) of specified size and shape including form work, plastering if specified size and shape including form work, plastering if required, curing etc as required. (volume of pole/pipe not to be deducted) as required at different places.
Dismantling of overhead lines comprising of aluminium overhead conductor, G.I. wire, cross arms, insulators etc. as required
Dismantling of pole in cement concrete foundation etc. as required.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared
Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long with charcoal/ coke and salt as required.
Total impact of GST for the purpose of CTC
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .