| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.8 CrAccepted-AOC | ₹36.8 Cr | L1 | Accepted-AOC As per Tender |
| 2 | L2₹38.2 CrRejected-AOC P AND C TOWERS 2ND FLOOR 140 PERUNDURAI ROAD ERODE 638 011 | ERODE | TAMIL NADU | 638011 | ₹38.2 Cr | L2 | Rejected-AOC As per Tender |
| 3 | L3₹38.9 CrRejected-AOC 5 217 D1 TEACHERS COLONY MOHANUR ROAD NAMAKKAL 637001 | NAMAKKAL | TAMIL NADU | 637001 | ₹38.9 Cr | L3 | Rejected-AOC As per Tender |
| 4 | L4₹39.4 CrRejected-AOC | ₹39.4 Cr | L4 | Rejected-AOC As per Tender |
| 5 | Rejected-Technical 10 243 THURAIYUR MAIN ROAD PONNERI POST NAMAKKAL 637013 | NAMAKKAL | TAMIL NADU | 637013 | - | - | Rejected-Technical As per PQ |
| Sl No | Description | Qty | Unit | P AND C PROJECTS PRIVATE LIMITED L2 | ABIRAMI ENGINEERING CONSTRUCTION AND CO L3 | PSK ENGINEERING CONSTRUCTION AND CO L1 | SSS HI TECH CONSTRUCTIONS PRIVATE LIMITED L4 |
|---|---|---|---|---|---|---|---|
| 1.00CIVIL WORK | |||||||
| 1.01EXCAVATION | |||||||
| 1.02Earth work excavation for foundation (for narrow excavation)in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2.00mts. and clearing and levelling the site, etc., complete complying with standard specification and as directed by the departmental officers. Note: The cost of earth work excavation shall be calculated based on the classifications of soils furnished in the trial pit details appended with the estimates | |||||||
| 1.03 | All Kind of Soil - (Upto 2.00m depth from NGL) | 2,903 | Cum | 211 ₹7.2 L | 200 ₹6.9 L | 225 ₹7.7 L | 350 ₹12.0 L |
| 1.04 | All Kind of Soil - (Upto 2.00m to 3m depth) | 640 | Cum | 222 ₹1.7 L | 200 ₹1.5 L | 260 ₹2.0 L | 550 ₹4.2 L |
| 1.05 | All Kind of Soil - (Upto 3.00m to 4m depth) | 140 | Cum | 233 ₹38,491.60 | 220 ₹36,344 | 280 ₹46,256 | 650 ₹1.1 L |
| 1.06 | All Kind of Soil - (Upto 4.00m to 5m depth) | 100 | Cum | 244 ₹28,792 | 230 ₹27,140 | 300 ₹35,400 | 800 ₹94,400 |
| 2.00FILLING | |||||||
| 2.01 | Refilling with excavated earth other than sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification | 1,916.06 | Cum | 105 ₹2.4 L | 100 ₹2.3 L | 130 ₹2.9 L | 150 ₹3.4 L |
| 2.02 | Supplying and filling in foundation, basement, etc with filling crushed stone sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. | 115 | Cum | 1,451 ₹2.0 L | 2,100 ₹2.8 L | 1,850 ₹2.5 L | 2,300 ₹3.1 L |
Tender Value
Refer Docs
EMD Value
₹17.5 L
Closing Date
25 Jul 2025, 3:00 pmClosed
Managing Director
No.4 Rajiv Gandhi Salai, Taramani, Chennai
Construction of IT Office Building, Ground floor plus 3 Floors plus Terrace, including Civil Construction, HVAC, Electrical HTLT, Elevator, IBMS, Fire Protection, Plumbing, Structural Facade, Landscaping, STP,WTP at Rasipuram in Namakkal
2025_TIDEC_574206_1
TIDEL/2025-26/09
Open Tender
Civil Works
Rasipuram in Namakkal Disrict
As per PQ
7 documents required · 7 mandatory
₹0
₹17.5 L
23 Sept 2025
26 Jun 2025
28 Jul 2025
26 Jun 2025
25 Jul 2025
20 Jul 2025
26 Jun 2025 - 9 Jul 2025
Amount
CIVIL WORK
EXCAVATION
Earth work excavation for foundation (for narrow excavation)in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2.00mts. and clearing and levelling the site, etc., complete complying with standard specification and as directed by the departmental officers. Note: The cost of earth work excavation shall be calculated based on the classifications of soils furnished in the trial pit details appended with the estimates
All Kind of Soil - (Upto 2.00m depth from NGL)
All Kind of Soil - (Upto 2.00m to 3m depth)
All Kind of Soil - (Upto 3.00m to 4m depth)
All Kind of Soil - (Upto 4.00m to 5m depth)
FILLING
Refilling with excavated earth other than sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification
Supplying and filling in foundation, basement, etc with filling crushed stone sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
Supplying and filling in foundation and basement with Excavated earth in layers of not more than 15 cm thick well rammed watered and consolidated complying with std spec.
Supplying and filling in foundation and basement with filling Quarry dust in layers of not more than 15 cm thick well rammed watered and consolidated complying with std spec.
Supplying and filling conveyed gravel other than sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying
Cement Concrete 1:4:8 (One Cement, four Crushed stone sand and eight hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete (The crushed stone sand to be used on concrete work shall confirm to gradation as per IS 383-1970)
Below plinth level.
floor level
Cement Concrete 1:5:10 (One Cement, Five Crushed stone sand and ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete (The crushed stone sand to be used on concrete work shall confirm to gradation as per IS 383-1970)
Below plinth level
Cement Concrete 1:5:10 (One Cement, Five Crushed stone sand and ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete (The crushed stone sand to be used on concrete work shall confirm to gradation as per IS 383-1970)
Flooring
FORM WORK
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)
Footing
Grade Beam
Coping beam
Column upto Plinth Level
Shear Wall upto Plinth Level
Lintel at all Levels
Sill Concrete at all Levels
Sunshade at all Levels
Staircase at all Levels
Column above Plinth Levels
Shear Wall above Plinth Levels
Roof Beam at all Levels
Roof Slab at all Levels
REINFORCED CEMENT CONCRETE
M35 Grade Concrete
Providing and laying in position, Standardised Concrete Mix M-35 Grade using In-situ Concrete batching plant/ Ready Mix Concrete (RMC) adopting weigh batch method in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 425 kg/m3 and maximum water cement ratio of 0.45, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m’) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges,
centering and shuttering and also including Conveyance of concrete from batching plant to Work site, Electricity charges and other works & labour cost involved for concrete production, laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).
Footing Concrete
Grade Beam
Floor Slab Concrete
Shear Walls
Foundations below the Plinth level
Column
Foundation column (Below the Plinth Level)
Column
Ground Floor
Terrace Floor
Roof Beam
Ground Floor
Terrace Floor
Coping Beam
Roof Slab
Ground Floor
Terrace Floor
M40 Grade Concrete
Providing and laying in position, Standardised Concrete Mix M-40 Grade in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cementcontent of 440 kg/m3 and maximum water cement ratio of 0.40, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m') 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges,
centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).
RCC Walll.
Foundation below the plinth level - Lift Wall
Column
Foundation column below the plinth level
RCC Wall
Ground Floor
First Floor
Second Floor
Third Floor
Headroom
Column
Ground Floor
First Floor
Second Floor
Third Floor
Terrace & Headroom
M - 25 Grade of concrete
Providing and laying in position, Standardised Concrete Mix M-25 Grade using In-situ Concrete batching plant/ Ready Mix Concrete (RMC) adopting weigh batch method in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kglm3 and maximum water cement ratio of 0.50, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m’) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges,
centering and shuttering and also including Conveyance of concrete from batching plant to Work site, Electricity charges and other works & labour cost involved for concrete production, laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials)
Lintel
Ground Floor
First Floor
Second Floor
Third Floor
Headroom
Sill Concrete
Ground Floor
First Floor
Second Floor
Third Floor
Headroom
Sunshade
Headroom
Staircase Waist Slab
Ground to First Floor
First to Second Floor
Second to Third Floor
Third to Headroom
Roof Beam - Regular
Ground Floor
First Floor
Second Floor
Third Floor
Headroom
Roof Slab - Regular
Ground Floor
First Floor
Second Floor
Third Floor
Headroom + OHT
STEEL REINFORCEMENT
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification, Grade of Steel ( Fy )- Fe - 550 Confirm to IS : 1786: 1985.
MASONARY WORK
Masonry work FlyAsh Bricks of size 230 x 110 x 70 mm in cement mortar 1:6 (one of cement six of sand) for sub structure & super structure in all floors including fixing frames of door and windows, proper setting, curing etc., complete complying with standard specification as directed by the departmental officers.The rates including curing, providing and removal of scaffolding, cost of materials, labour, equipments and machinery, all leads and lifts, loading and unloading, transportation and all other incidential charges etc, all as complete and directed by Engineer in charge at all levels.
For Foundation and Basement.
For Superstructure in Ground Floor
For Superstructure in First Floor
For Superstructure in Second Floor
For Superstructure in Third Floor
For Superstructure in Terrace Floor
Providing and fixing 100mm thick Double skinned gypsum board partition, using 2 nos of 12.5mm thick tapered edge gypsum board fixed on either side of 48mm metal studs,floor & ceiling,channels spread at 610mm c/c on either side. Joints between boards shall be fixed with jointing compound and special paper tapes.The partition should have 100% acoustic insulation using high density glass wool insulation with double packing using polythene cover .Actual measurement of partition will be paid after deducting the glazed portion and door opening (If any) .The connecting timber work cost should include in the cost of gyp board partition
For Superstructure in Ground Floor
For Superstructure in First Floor
For Superstructure in Second Floor
For Superstructure in Third Floor
Brick partition walls of 11.50cm thickness using best quality Fly Ash Bricks of size 23 x 11 x 7 cm in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers.The rates including curing, providing and removal of scaffolding, cost of materials, labour, equipments and machinery, all leads and lifts, loading and unloading, transportation and all other incidential charges etc, all as complete and directed by Engineer in charge at all levels.
For Superstructure in Ground Floor
For Superstructure in First Floor
For Superstructure in Second Floor
For Superstructure in Third Floor
For Superstructure in Parapet & Headroom
Damp proof course with Cement Mortar 1:4 (One Cement and Four crushed stone sand) 12mm thick mixed with best approved quality water proofing compound conforming to Indian Standard specification as specified by the departmental officers at 2% by weight of cement used, finishing and curing etc. complete complying with standard specification.
For Main Building
JOINERIES
Supply and erection of Double Leaves Fire Rated Door with Frame having the dimension of 1800mm x 1400mm with following specification: a. Door Frame 1.6mm: Galvanized 120 GSM branded make JSW b. Door Leaf 1mm: Galvanized 120 GSM branded make JSW c. Shutter Thickness: 46mm d. Honeycomb: In-fill e. Glue Macroplast UR-7221 f. Door Hinges: 4" x 3" x 3mm, Double Ball: Make Assa Abloy Yale Ball bearing Butt Hinges Grade SS 304 - Finish SS
g. Door Closer with Standard Arm Finish: Silver
h. Lock Set: Dead Lock with both side key
i. Door Orientation: To be confirmed by client
j. Mounting of door: Brick wall mounted
k. Powder Coating: Powder coated in standard RAL paint
colour of PO Red (60 to 90) Microns
l. Single Point Panic Bar (2 Horizontal): Make Assa Abloy Yale or Equivalent
m. Dead Lock with both side key: Make Assa Abloy Yale or Equivalent
n. Vision Panel 200 x 300mm 2 Hrs. Fire Glass Schott Pyran with Frame
o. Rated Glass Schott Pyran with Frame
p. Anchor Bolt with Endcaps
The above assembly mounted on concrete or brick wall
including the cost of cutting, chipping, concrete packing,
pastering, scaffolding all other conveyence as per standard methods and as directed by the Departmental Officers.
Staircase
AHU and Electrical Room
Providing and fixing 12mm thick frameless toughened glass door shutter of approved brand and manufature including providing and fixing top and bottom pivot and double acting hydraulic floor spring type fixing arrangement and making necessary holes etc for fixing required door fittings , all complete as per direction of Engineer in charge ( door handle, lock and stopper etc to be paid separately)
Single Leaf Door - (1200 x 2400mm)- MSD - Terrace
Double Leaf Door - (1500 x 2400mm)
Providing and fixing Sliding door operator, compliant with future European standards and produced according to the guidelines for power-operated windows, doors and gates, BGR 232, the UVV and the VDE regulations. TÜV design tested for Durability of 1,000,000 Cycles, Manufactured according ISO 9001, tested according to the low voltage guidelines, CE Compliant, fulfils DIN 18650 standards for Padestrian Safety, for framed glass door application with DORMA ST-Flex Profiles Systems, modular design including internal cover and with 12.52 mm Laminated glass for 1 Nos sliding door panels and 1 Nos fixed panels,
both sliding & fixed panels with ST-Flex framed profile system with Interlocking Seals.Operator & Frame Finish should be Silver Anodised, with operator dimensions (H x D) : 100 x 180 mm and of length as required to suit the opening sizes as given below ES200 Operators are of very sturdy design with Self balancing Panel suspension system and with Anti-Jump fitting.The track profile should be separate from the main profile for enabling reduction in vibration insulation. Microprocessor-controlled control unit, Self-learning, with adjustable parameters for opening and closing speed, hold-open time and opening and closing force, reversing when obstruction is encountered, Class of protection IP 20 with SMPS for Power regulation. Activators- Nemo Motion + Nemo Dual ( Safety & Motion ) Pack, EM Lock - Fail Safe with CableProgram Switch with Key. Max Panel Weight Carrying Capacity of 1 X 200 Kgs. The system shall have constant power supply 230V+ 5%, 50Hz, AC . The requirement in total is as mentioned below:
Supplying and fixing of Teak wood door frame of size 100x75mm with solid core flush shutter of following type with thickness and necessary T.W. internal lipping alround conforming to IS 2202-1(1999) including cost of wind appliances and furniture fittings such as 3 Nos of SS 304 Grade Parliament Hinges of Size (125mm x 150mm) , 2 Nos 300x12mm aluminium tower bolt 1 No. 200x12mm aluminium tower bolts 1no. 250x16mm aluminium aldrops, 2 nos. 200mm ‘D’ type aluminium door handle and door stopper with bush etc., complete complying with standard specification and as directed by the departmental officers - Single leaf. Door Shutter Type : Flush shutter Thickness:35mm
UPVC Ventilator : Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
UPVC Glazed Windows in Elevation : Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
Rolling Shutter - RS 78GI Curtain made of single skinned galvalume steel laths with Natural finish . Pressed galvalume steel hood & motor cover with natural finsh . CE Certified CRS Compact Gear P.R.C Make Indirect Drive Operator. Three station push button with deadman control.
M.S GRILLS
Supplying and fixing mild steel grills for windows, ventilators, etc., including priming coat etc., complete.
SS HANDRAIL
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia. Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete
Providing and fixing of 3 Nos of stainless steel grab bars for special need including all fixtures and complete finish.
PLASTERING
Plastering Internal with Cement Mortar 1:5 (One cement and M.sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the Engineer-incharge.
Ground Floor
First Floor
Second Floor
Third Floor
Headroom
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three M.Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the Engineer-in charge.
Prepare surfaces and plaster with CM 1:5 (1 cement: 5 fine sand) 20mm thick(12mm+8mm) to all exterior faces of walls including hacking as required on RCC surfaces continuous to masonry in super structure and 12mm will be rough plastering includes water proofing chemical compound and 5mm will be sand paper finishing & double layer chicken mesh .The rates including curing, providing and removal of scaffolding, cost of materials, labour, equipments and machinery, all leads and lifts, loading and unloading, transportation and all other incidential charges etc, all as complete and directed by Engineer in charge at all levels.
Prepare surfaces and plaster with CM 1:5 (1 cement: 5 fine sand) 18mm thick(12mm+6mm) to all exterior faces of walls including hacking as required on RCC surfaces continuous to masonry in super structure and 12mm will be rough plastering includes water proofing chemical compound and 5mm will be sand paper finishing & double layer chicken mesh .The rates including curing, providing and removal of scaffolding, cost of materials, labour, equipments and machinery, all leads and lifts, loading and unloading, transportation and all other incidential charges etc, all as complete and directed by Engineer in charge at all levels.- BASEMENT HEIGHT
Plastering with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 12mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including mortar plasticizer at 200ml per 50Kg of cement used, finsihing, curing, etc., complete in all floors complying with standard specification and as directed by the departmental officers.
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
PAINTING
White washing two coats with best shell lime in all floors complete complying with standard specification and as directed , including gum, conjee, water, etc., complete.
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
Painting two coats of newly plastered wall surface with Weather Proof Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
Providing and applying Texture Finish Paint (for External painting) and approved shade including preparation of surface for painting, applying primer and two or more coats of paint as per manufacturer’s specifications, scaffolding curing etc. complete as directed at all levels.
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Painting new wood/iron work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
White washing ONE COAT with best shell lime in all floors complete complying with standard specification and as directed , including gum, conjee, water, etc., complete.
Emulsion painting to ceiling of Cafeteria complete complying with standard specification and as directed ,complete.
FLOORING
Supplying and fixing superfine polished Ruby red or equivalent colour Granite slab 20 mm thick for Lift facia Cladding with bullnose edges are set in CM 1:3 10mm thick for base and pointed with the same colour cement etc complete. The rate inclusive of labour charges for laying & pointing curing etc. complete
Supplying and fixing pre polished Ruby red or equivalent colour Granite slab 20 mm thick for Pantry and wash basin counter with bullnose edges are set in CM 1:3 10mm thick for base and pointed with the same colour cement etc complete. The rate inclusive of labour charges for laying & pointing curing etc. complete
Supplying and fixing pre polished Ruby red or equivalent colour FLAMED Granite slab 18mm thick for stair case Tread & riser set in CM 1:3 20mm thick for base and pointed with the same colour cement etc complete. The rate inclusive of labour charges for laying
Providing the floor with 20 mm thick Granite slabs- 1200x600 mm of approved colour and size in all floors over a base layer of 20 mm thick CM 1:3, the granite slab be laid over the cement mortor by applying white cement slurry in between base mortor and granite slab. The granite slabs are to be so laid that there should not be any gap inbetween the adjacent slabs and the joints shall be in line with another joint and uniform by using cutting machine without any damage to the sides of corners of the granite slab. The entire area of the flooring so laid shall be neatly pointed with coloured cement of 1.80 kg/m2. The granite slabs proposed for the work shall be shown to the departmental officers and got approved by them before use in the work etc., complete.
Dadoing walls with following best approved quality, white / colour Glazed tiles of approved sizes set in Cement Mortar 1:2 (One Cement and Two M.sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers.
Paving the floor with best quality Virtified Tiles of size 300 x 300 x 8mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three M.sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Paving the floor with best quality Virtified Tiles of size 600 x 600 x 8mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three M.sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Providing Granolithic floor finish 40mm thick with Plain Cement Concrete 1:2:4 using 3 to 10mm ISS HBG metal, river sand and including rubbing the top surface smoothly thread lining if found necessary and curing etc. complete complying with standard specification and as directed by SIPCOT Officers including cost and conveyance of all material and labour, incidental charges, etc. complete.
40mm thick
Supplying & laying of Solar reflective index tiles 305 x 305 x 7 mm of 30 mm thick in cement mortar 1:3, 30 mm thick using white cement and hard crate mixed same colour pigments etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) - IN OPEN TERRACE AREA.
WATERPROOFING
TERRACE WATER PROOFING
Surface Treatment: Providing and laying water proofing treatment of podium including cleaning the surface with wire brush, treating all surface cracks, construction joints and honeycombs by grouting with specialised non shrink grout and preparation of surface in all aspects to receive the waterproofing.
Bore Packing / Core Cut Treatment: Providing and sealing the gaps in the core cuts around PVC pipes treated with ReArm Bond SBR 45 bonding agent & sprinkled sand; using a non shrink grout ArmGrout M 50 or equivalent of followed by sealing of the same joint by using Joint Tape SealArm Joint Tape 2000 or equivalent with Epoxy adhesive.
Coving: Providing and Applying at the junction of slab and vertical offsets with Cement Mortar 1:4 and admixed with ReArm Bond SBR 45 at dosage of 1Ltr per 50kg cement.
Application of Primer: Apply Water based Epoxy based primer FloArm Primer EPW 44 of MYK Arment or equivalent over well prepared surface at 200-400 gm per Sq.Mtr.
Application of Polyurethane waterproof coating: Providing and applying Two coats of liquid applied single component polyurethane based waterproofing system AquaArm WPU-1KE of MYK Arment or equivalent . It has to be applied 2.6 @kg/sqmtr to achieve a thickness of 1.2 mm in two coats.The membrane will have the following technical parameters: Tensile Strength : 1.4 N/mm2 ,. Elongation at break : 450% , Adhesion To concrete: >1.5 N/mm2,
Providing and laying 150 Gsm Geo fabric membrane as separation layer
Protection Screed: Horizontal Areas: Providing and Laying M25 grade screed concrete in 1:100 to a average thickness of 100 mm mixed with Integral Waterproofing admixture AquaArm Proof WP 10 at the dosage of 125 ml/bag of cement over waterproofing layer to a minimum thickness of 75 mm as per site requirement(Civil Contractor Scope) including control joints of 4M X 4M size and filling the panels with polyurethane sealant.
Water Stops for Joints : Supply and apply of WPM SW a swellable waterbar based on polymer technology and designed for use in construction joints.
LIFT & OHT W.P
Surface Preparation: Providing and laying water proofing treatment to horizontal and vertical surfaces of podium slabs, including cleaning the surface with wire brush, treating all surface cracks, construction joints and honeycombs by grouting with specialised non shrink grout,coving preparation at wall - slab joint and preparation of surface in all aspects to receive the waterproofing.
Bore Packing / Core Cut Treatment: Providing and sealing the gaps in the core cuts around PVC pipes treatedwith SBR bonding agent & sprinkled sand; using a non shrink grout ArmGrout M 50 or equivalent of followed by sealing of the same joint by using Joint Tape SealArm Joint Tape 2000 or equivalent with Epoxy adhesive.
Coving: Providing and Applying at the junction of slab and vertical offsets with Cement Mortar 1:4 and admixed with SBR at dosage of 5 litre per 50kg cement. (cement and sand shall be supplied by the main contractor)
Waterproofing Coating-Providing and applying two compoent acrylic cementitious coating AquaArm TG of MYK Arment or equivalent with a coverage of 2.0 kg /m2 .The coating shall be taken upto 300mm from finished floor level on the vertical walls.The coating shall have an elonagtion of 40%,Shore A hardness of 90,Tensile strength of 0.86 N/mm2.
TOILET- SUNKEN PORTIONS
Surface Preparation: Providing and laying water proofing treatment to horizontal and vertical surfaces of podium slabs, including cleaning the surface with wire brush, treating all surface cracks, construction joints and honeycombs by grouting with specialised non shrink grout,coving preparation at wall - slab joint and preparation of surface in all aspects to receive the waterproofing.
Bore Packing / Core Cut Treatment: Providing and sealing the gaps in the core cuts around PVC pipes treatedwith SBR bonding agent & sprinkled sand; using a non shrink grout ArmGrout M 50 or equivalent of followed by sealing of the same joint by using Joint Tape SealArm Joint Tape 2000 or equivalent with Epoxy adhesive.
Coving: Providing and Applying at the junction of slab and vertical offsets with Cement Mortar 1:4 and admixed with SBR at dosage of 5 litre per 50kg cement. (cement and sand shall be supplied by the main contractor)
Waterproofing Coating-Providing and applying two compoent acrylic cementitious coating AquaArm TG of MYK Arment or equivalent with a coverage of 2.0 kg /m2 .The coating shall be taken upto 300mm from finished floor level on the vertical walls.The coating shall have an elonagtion of 40%,Shore A hardness of 90,Tensile strength of 0.86 N/mm2.
FALSE CEILING
GYBOARD FALSE CEILING
Providing and fixing in position M / F suspended false ceiling to detail as per drawing with GI frame work and 12.5mm tapered type gyp board panels to form grids of 457 x 1220mm as per manufacturers specification including provision for stepped shaped ceiling for light trough comprising.
Frame work of intermediate channels (M.F.T.) at 1220mm centres along one direction M/F ceiling section MF5 at 457mm centres along other direction. Perimeter channels (MF 6A) along walls alround perimeter side of the ceiling, all to detail as per drawing.
The intermediate channels suspended from ceiling, through strap hangers 25 x 0.5mm (MF 8) at 1220mm centres connected to soffit cleats P534 (27 x 37 x 25 x 1.6mm) the cleats connected to ceiling through metal expansion rawl plugs 12mm dia and 17/16" long with necessary bolts and nuts etc. all connected with additional perimeter channels (MF 6A) for openings for light fixtures, AC ducts, vertical drops, offsets etc. wherever necessary all to detail and as per direction.
12.5mm thick gyp board with tapered edges fixed to underside of suspended grid with 25 mm screws to form grids of 457mm x 1220mm varied along wall ends etc. including Architectural boxing,design and painting the underside of gyp board with 2 coats of plastic emulsion paint of approved colour over a priming coat etc., complete.
ARMSTRONG GRID FALSE CEILING
Providing & Fixing of Armstrong Mineral Fibre Acoustical Suspended Ceiling System with Classic Max Beveled Tegular Edge Tiles with Armstrong Suprafine 15mm Exposed grid. The tiles should have Humidity Resistance (RH) of 99%, NRC 0.7, Light Reflectance ≥85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) with pin-hole visual in module size of 600x600x17mm, suitable for Green Building application, with Recycled content of 65%. The tile shall be laid on Armstrong Suprafine 32 with 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 32 mm and a load carrying capacity of 8.8 Kgs/M (as per standard installation layout mentioned below) & pull out strength of minimum 100 Kgs. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system of Armstrong make.The Tile & Grid system used together should carry a 30 year warranty.
INSTALLATION: To comprise main runner spaced at 1200mm securely fixed to the structural soffit using Armstrong suspension system (specifications below) at 1200mm maximum. The First/Last Armstrong suspension system at the end of each main runner should not be greater than 450mm from the adjacent wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be Armstrong wall angles of size 3000x19x19mm, secured to walls at 450 mm maximum. Installation to be carried out by Armstrong Trained Installation team & Installation should be carried out as per Armstrong recommended procedure.
ARMSTRONG SUSPENSION SYSTEM accessories manufactured and supplied by Armstrong World Industries consisting of M6 Anchor Fasteners with hanger hole, pre Straightened Hanger wire of dia – 2.5 mm of 1.80 m length having a tensile strength of 344-413 MPa and a minimum pull strength of 110 kgs. (Adjustable hook clips of 0.7mm thick, galvanized spring steel can also be used for installation purpose as an additional accessory. The adjustable clip also consists of a 4 mm aquiline wire to be used with the main runner).Tentative Pricing for Supply and Installation of Classic Max Microlook Tile with 15mm Suprafine 32H Grid
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm andecondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle ofsize 24x24x0.3 mm and
laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mmcenter to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
Supply and installation of of FAMELINE GI Plain Lay-in ceiling system using FAMELINE GI grid work with Main Runners of size 15mm X 32mm X 3600mm X0.3mm and Cross Runners of Size 15mm X 32mm X 1200mm X0.3mm and 15mm X 32mm X 600mm X0.3mm which snap locked in with each other forming a 600 X 600mm grid work. The suspension system comprises a Rawl plug fixed to the true ceiling and mend to 3mm GI rod knit to a ‘J’ bolt which holds the Main runners at every 1.2m intervals. Finally FAMELINE GI Plain Lay-in Tiles of Size 595mm X 595mm X 0.5mm (T) are laid upon the formed grid. The price should include the cost of making any cuts and openings for lights and other fittings. The hold down clips should be fixed with wall angles to hold down the end tiles -
Toilet cubicle : Providing and fixing toilet cubicle of following standard dimension which includes 600mm door size width made of heat, bacteria, water, chemical, scaratch, impact and bacterial ressitant 12mm thick solid compact laminate panels finish of the compact laminate sholud be raw silk which include doors, piasters and intermediate panels finished with approved texture/ shade as per the detail drawing and asper IS 2046 ( INDIAN STANDARD )ans as per fire retardant BS -476/97 standard. This also includes providing and fixing in necessary hardware made out of Stainless steel ( Grade 304) as per Manufaturer;s specification and EIC instruction like (1)door Knob, (2), gravity hinges, (3),thum turn lockset indicators ,(4) coat hooks,(5) U- Channels, (6) SS Shoe box plate (7) MS- Base plate, (8)Rubber noise deafening tape (9) Screws ans wall plugs.
All Screws will be of 304Grade in Stanless steel with satin finish. All piasters are supported by series stainless steel shoe box with MS base plate The base of stainless steel shoe box will be anchored to the floor with a clearance height up to 110mm. Fixing of intermediate panels to the wall shall be stainless steel L- Bracket of stainless U - Channel section are fixed in to wall with screw inserts.All screws will be 304 Grade in Stainless steel with satin finish. All piasters are supported by stainless steel bottom cladding.The base of the stainless steel bottom cladding will be anchored to the floor with a clearnce height of 110mm.All intermediate panels shall be 12mm thick, piasters and door shall be 18mm thick with edges chamferred complete as per Drawing and directions of Engineer-in - Charge.
Toilet cubicle with standard Dimension of 1840mm height x1000mm width x1550mm depth, Which includes 600mm door size width . Toilet cubicle I- Shape ( Front portion ) with standard dimension of 1840mm height x1000mm width Which includes 600mm door size width)
URINAL PARTITIONS : Providing & fixing Greenlam Sturdo Urinal Privacy Dividers self-supporting 12mm thick compact laminates made out of, urea free, thermosetting phenolic resins treated Kraft papers as core material and Amino plastic resin treated decor papers on the finish surface, conforming to latest and applicable IS: 2046-1995, EN 438:2016 and NEMA LD3-2005 quality standards with Antivirus, Antibacterial and Antifungal properties (conforming to ISO 21702:2019, JIS Z2801:2010 and ASTM G21-2015 standards respectively) to fulfil the applicable requirements of indoor air quality certifications for Greenguard-Gold standards.
12mm thick compact laminate size 400mm(D) x 1190mm(H), joined by using H profile ,Aluminium grade 6063-T6 in natural anodised finish. Fixed on wall with the help of SS grade 316 brackets.
MISCELLANEOUS
Providing Anti-termite treatment to soil adjecent and under building foundation, plinth periphery of the building by application of chemicals of IS 63613 part I to IV in stages to suit the progress of work consist as per the detailed specification as below. Including breaking of termite mounds, making holes with crow bar, closing the holes after the treatment and including cost of chemicals, labour charges, transport and storing etc., complete and as directed by the departmental officers.
Sunken filling in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.
Supplying and fixing in position CI manhole covers with CI frames (Heavy duty) of size 60cm x 60cm of best approved quality as per standard specification etc., complete compying with standard specifications
Providing and fixing PVC coated PVC rungs as per drawing and instruction of Engineer in-charge complete.
Providing V groove making for lift wall Granite and staircase tread slab including cleaning etc complete , Rate only for labour charges including necessary tools .
Full nosing making for lift wall Granite and staircase etc complete including cleaning , The rate only for labour charges including necessary tools etc.
Providing, fabricating and fixing in position M.S. Structure made out of M.S. rolled/hollow (rounds/rectangular/ square etc.) sections as per architect’s details including shearing /cutting, riveting, welding, grinding to smooth surface of all works.
Providing and fixing of Gypsum board border of required height up to 150mm at the joints of grid false ceiling areas
Providing and fixing of bison board of specified thickenss as per standard specification and as directed by the deparmental officers, in Glazing and roof area.
Providing and fixing of Calcium silicate board with Aluminium frame work of specified thickenss as per standard specification and as directed by the deparmental officers, in ring main area.
Providing Plaster band on columns sides of 100mm wide with neat finish
ELEVATION
STRUCTURAL GLAZING - SEMI UNITIZED SPLIT MULLION SYSTEM
Providing and fixing Semi Unitized Structural Glazing using aluminium framework system having separate main framework of split mullion and special transom with separate glass panel frame all made out of extruded aluminium sections colour anodized / powder coated of approved shade (as per details below) to withstand wind pressure up to 200 kgs/sqm for span of 4.2mts and vertical spacing up to 1.10mts. Extruded section shall be 6063 - T6 alloy temper confirming to ASTM B221 or approved equivalent. Main frames are designed to be assembled for each individual panel and one floor height in ladder form suiting the grid required. The System of Split Mullions with male and female verticals allows the panels to be assembled at angle to suit the segment of Curved / Straight shape of façade wherever required. MS brackets (hot dipped galvanized 80microns) designed for maximum plumb line deviation up to 30mm to be fixed to building structure with 10mm dia anchor fasteners. The main aluminium frame to be fixed to bracket with suitable SS bolt/nut washer. The complete framework to be aligned and leveled as required.
SYSTEM – The system to be designed to take horizontal and vertical movement up to 10mm for every floor and capable of withstanding wind pressure of 2 kpa for floor height of 4.2 mts and spacing of 1 mts. The system design should be gasket based to accommodate double or single glass as maybe required. The rate includes detailed design calculations taking into consideration the wind load, dead load etc. as per relevant I.S code / international code and approved by qualified Structural Consultant. The system should include for if required open able panels Top Hung with S.S heavy duty self balancing friction hinges and multi point handle cum lock. Main frame to be assembled as per design required and fixed to prefixed clamps with SS bolt/nut & washer. The framework thus fixed to be properly aligned and leveled to required grid work. The glass frames suitably glazed as described above with glass fixed to main frame with suitable S.S Toggle plates and glass support clamps. The gaps between panels are properly sealed with weather sealant (DC789) to ensure no leakage and work completed as per design and specification. SYSTEM COST
Double Glass
DGU GLASS 6mm thick Reflective HS glass - Dark Blue SKN 744 / 733 + 12mm airgap + 6mm thick clear toughned glass
Single Glass
SGU GLASS 6mm thick Reflective HS glass - Light blue ST 767
SPANDREL INSULLATION
Providing and fixing of Spandrel panel made up of 1.2mm thick G.I Sheet Tray insulation with rock wool slab of 48Kg/ cu.m.Density for 50mm Thk. Providing a face covering of rock wool fiber cloth ( Black Colour).. This wool should be provided with suitable fixing arrangements with aluminium angles and the slab shall be tied with G.I holding pin into already fixed aluminum angle to the structure. Rock wool slab should be provided in the gap between the Structural glazing framework .Rate to include the cost of necessary sealant between tray and aluminium frame work including all necessary accessories etc complete.
EXTRA FOR TOP HUNG OPENABLE
Providing and fixing top hung openable panels 1.20 X1.20 M at desired location in the structural glazing system , including providing and fixing of one pair of required size of stainless steel friction stay with minimum 4 point locking system, restrictor arm with release key , handle including all necessary accessories , additional framing work etc all complete.
ALUMINIUM COMPOSITE PANEL CLADDING
Supplying and fixing aluminum composite panels to detail as per drawing and job for external cladding in combination of approved color of Eurobond FR Grade or Equivalent including all necessary framework and using aluminum frame L angle section , HDGI MS brackets , GI bolt /nut washeres , SS screws & aluminium pop rivets . Wherever shown in the drawing and wherever it is necessary as wind bracing fixed at the rear side of the cladding panel using tray type method fixing or approved equivalent frames fixed to the RC columns / walls using necessary aluminum cleat with required size of GI anchor fasteners and complete weather sealing. The composite panel of weather resistant 4mm thick consist of 3mm LDPE resin core, sand witched between 2 skins of 0.5mm thick, Aluminum sheet (alloy designation 3000 series ) making a total panel thickness of 4mm approved make and color for the cladding bent to shape at grooves width of grooves angles firmly and grooves to be closed with weather sealant of approval make for 12 to 16mm
The surface will be finished with fluorocarbon -, coating in topsides and service coating on reverse side coating confirms to the mechanical properties of panel as per detailed technical specification , shall include all fixing accessories, wind breaching, screws, washers, bolts, nuts, cleats, other required fasteners, sealant brackets, etc.,complete.
ALUMINIUM LOUVER
Providing and fixing of 50 Microns colour Powder coated aluminium louvers 63 x 38 x 2mm thick outer frame and intermediate mullions with , 100 mm Z blade with aluminium plate including angle at top & bottom with and other necessary hardwares etc. all complete
GLASS CANOPY
Providing and fixing of Glass Canopy work as per drawing. The glass canopy will be designed with M.S section as main rafter / cross members , MS Base plate of required size, adequate numbers of anchor fasteners , aluminium framing work to support the glass panels . Canopy will be provided with glass covering of 13.52mm laminated glass ( 6mm thick clear toughened glass + 1.52 PVB + 6mm thick clear toughened glass ) glass panels with clear sealant etc all complete. Exposed MS members shall be painted with required one coat of primer and two Enamel painting etc. complete.
AUTOMATIC SLIDING DOOR
Providing and fixing of 12MM THICK CLEAR TOUGHENED GLASS WITH FROSTED FLIM - DOOR SIZE 2.4 x 4.0
ALUMINIUM COMPOSITE PANEL CLADDING (Wooden Finish)
Supplying and fixing aluminum composite panels cladding The system to detail as per drawing and job for external cladding in combination of approved color of Eurobond wooden finish ACP / Equivalent including all necessary framework and using aluminum frame L angle section , HDGI MS brackets , GI bolt /nut washeres , SS screws & aluminium pop rivets . Wherever shown in the drawing and wherever it is necessary as wind bracing fixed at the rear side of the cladding panel using tray type method fixing or approved equivalent frames fixed to the RC columns / walls using necessary aluminum cleat with required size of GI anchor fasteners and complete weather sealing. The composite panel of weather resistant 4mm thick consist of 3mm LDPE resin core, sand witched between 2 skins of 0.5mm thick, Aluminum sheet (alloy designation 3000 series ) making a total panel thickness of 4mm approved make and color for the cladding bent to shape at grooves width of grooves angles firmly and grooves to be closed with weather sealant of approval make for 12 to 16mm.
The surface will be finished with fluorocarbon -, coating in topsides and service coating on reverse side coating confirms to the mechanical properties of panel as per detailed drawing shall include all fixing accessories, screws, washers, bolts, nuts, cleats, other required fasteners, sealant brackets, etc., complete.
Providing and fixing of Aluminium box sections of size 100x50x3mm for pergoa at terrace floor including all accessories etc complete as per manufaturer specifications
INTERIOR WORKS
Wall Panelling:-Providing Wall Panelling using one side teak wood sheet with melamine polishing with following specification. The frame using aluminium tubular section of size 50mm x 25mm x 2mm thick fixing horizontally and vertically in position with wall at interval of 0.60m in both diretions, fixing water proof plywood of 12mm thick over the aluminium frame work with necessary screws. One side teak wood sheet of 3.5mm thick will be fixed over the plywood using fevical and finishing with melamine polishing and the rate inclusive of conveyance to site and labour charges and as directed by the Departmental Officers. The design pattern, water proof plywood, OST sheet and other materials to be used shall be got approved by the Executive Engineer concerned before use on work etc., complete.
Providing & fixing concept Vertical Blinds etc. as per direction of engineer-in charge.
Providing & fixing concept wallpapers with wording & arts etc. as per direction of engineer-in charge.
SIGNAGES
Reception Table
10''x36'' , Titanium Gold Letter - TIDEL NEO
Reception Back Drop
15''x48'' - TIDEL
Building Elevation Arch Design
Tidel Neo - LED Trim cap letters
English - 36''x180''
tamil - 36''x150''
Compound wall - Arch
Tidel Neo - LED Trim cap letters
English - 36''x180''
RASIPURAM
NAMAKKAL
Lift Lobby
Tidel Neo - LED Trim cap letters
English - 24''x90''
Reception mural art wall below
Neon Light signage
Main entrance ISLAND TITEM Pillar double sided
with Civil works scaffolding etc
Location
one No behind entry gate
One no behind exit gate
Reception back drop way finding
Parking signages - Car parking
Carparking
Bike parking
Combined total signages
Building facility identifications
Service signages
STP, TANK YARD
Single sided wall mounted
Tidel office- wall mounted without lighting
24''x48'', 3d letters
Conference room - wall mounted above door frame
Titanium single sided
Individual room - 8''x36''
Office signages- 1 to 36 nos
24''x24'' square, titanium letter acrylic titanium top
ELECTRICAL WORKS
HT PANEL
22KV HT RINGMAIN GEAR UNIT (OUTDOOR)
Supply, Installation, Testing and Commissioning of 22 kV Outdoor type Ring Main Gear Panel, Metal Clad totally enclosed, dust and vermin proof, floor mounting, free standing type made up of 2 mm thick CRCA sheet with powder coated of approved shade, IP 55 with 1 No of load break switch of 800 Amps capacity, mechanically interlocked earth switch 2 NO + 2 NC auxiliary switch with mechanical ON/OFF indication and 1 No Vacuum circuit breaker of vertical / horizontal isolation, horizontal drawout type, rated for 800 A with 31.5 kA/3sec fault withstand generally conforming to IS : 13118, mounted on suitable channel iron including grouting the channels etc as required
22 kV Outdoor type RMG panel comprising of the following:
1) 22 KV, 800 A, 31.5 KA/3Sec Horizontal Draw out, vertical / horizontal Isolation 1 No. VCB fitted with manual / Motor operated spring charging Mechanism with 230 V AC, shunt trip coil of 110 V DC, closing coil of 110 V DC, Auxiliary Contact 6NO + 6NC, Mechanical ON / OFF indicator, mechanical operation counter, Automatic safety shutters, Push button and breaker position indicator including epoxy insulator - 1 set
2) 22 KV, 800 A, 31.5 KA Load Break Switch with Earth switch, with 2 NO + 2 NC Aux. Contacts - 1 Set
3) 22KV Single Phase, Resin Cast, Dry type, Fixed type PT with 1Amps, HT fuses of ratio (22KV/1.732)/(110V/1.732)/(110V/1.732) Core1: Cl: 0.2,Burden : 50VA for Metering, Core 2: Cl:3P, Burden: 50VA for Protection - 3 Nos
4) 22KV Resin Cast, Dry Type Current Transformer of Ratio (75-30)A/1-1A, Core1: Cl:0.2s, Burden : 15VA for Metering, Core 2: Cl:5P10 Burden:15VA for Protection STC 31.5KA/1Sec- 3 Nos
5) Digital Multifunction Meter with RS485 Port, Cl:0.2s 110V AC
6) Secondary self aligned plug in contacts -1Set
7) Antipumping Relay, 110V DC,(94)- 3Nos
8) Numerical Over Current & Earth Fault Relay -110V DC, (50/51/50N/51N/95) With RS485 Port -1 set
9) Master trip Relay, 110V DC,(86)(3 NO + 1 NC) -1 set
10) Under Voltage/Over Voltage Relay, 110V DC,(27/59) - 1 No
11) R/Y/B Indication Lamps – 110V AC- 1Set
12) VCB On/Off/Auto Trip/Spring Charge/Trip Circuit Healthy/Breaker in Service/Breaker in Test Indication Lamps – 110V DC .
13) LBS On/Off Indication Lamps – 110V AC
14) Trip Circuit Healthy Push Button with NO Element
15) Breaker Control Switch (Close-Neutral-Trip)-Non Lockable -1 Set
16) Heater ON/OFF switch with filament type space heater and thermostat, Single phase switch with socket, Cubicle illumination lamp-1 Set
17) Suitable Battery Packed Power Pack 230V AC /110V DC, with 7AH Battery as required. - 1 No
18) Test terminal block - 1 No
19) Space for TOD Meter
20) Suitable capacity 2P/4P AC MCB/ DC MCBs- 1Set
21) Control fuses, ferrules & copper Control wiring with 2.5 Sq mm for CT & VT Circuit and with 1.5 Sq mm for other AC & DC control Circuit etc.
22) 8 Window Annunciator with Test/Mute/Reset/Acknowledge Push Button inbuilt Hooter with RS485 Port ,110V DC - 1 No
23) 18KV 10KA Indoor Panel Mounted Surge Arrestor, Class 1 - 3 nos.
24) Power terminals suitable to receive incoming & outgoing XLPE cable without termination kit & copper earth bus (50 mm X 6 mm)
25) The makes and accuracy of meters, CTs & PTs shall be as per TNEB / TANGEDCO requirement.
26) MS sheet steel enclosure suitable for Outdoor Installation, Powder Coated of approved shade after 7 tank treatment process, with seimens grey paint finish RAL 7032 etc. complete as required.
22KV 4 VCB PANEL ( OUTDOOR)
22 KV, 31.5 KA/3sec, 800 A, HT 4 VCB Panel complete as per specification Draw out type 22 KV 31.5kA/3sec 800 A. Horizontal Draw-out/Horizontal Isolation VACUUM CIRCUIT BREAKER , with Motor (230 V. AC – AC source of supply will be provided) operated Spring charged Mechanism Anti Pumping Device, 110 V DC Shunt Trip and Closing Coils. DC source of supply derived from power pack with battery back up suitable for 3 Tripping and Two Closing operations. Power pack shall be provided with alarm and LED indication Contact for customer use, Automatic safety shutter, Mechanical Close/Trip knob, Mechanical in case of failure of DC output. Mechanical Operation Counter, 4 NO + 4 NC Spare Aux. ON/OFF Indication etc. for a single incomer at receiving point.
Current Transformers:
3Nos Current Transformers of 100/5 Amps – 15 VA 5 P 10 for Protection at incoming side.
3Nos dual ratio Current Transformers of 75-30/5A at outgoing side – 15 VA Class 0.5 for Metering
METERING:
Digital Multifunction Meter –SPZ or Eqv make.
PROTECTION
Numerical relay with following features
2.Three phase time over current protection
3.Three phase instantaneous over current protection
4.Earth time over current and earth instantaneous over current protection
5.Event counter, fault recorder, trip counter , digital programmable etcc..
6.Rs 485/USB Communication(Local/remote)
7.Potencial free contacts for breaker on, off and trip status monitoring through BMS.
Master trip relay, Auxiliary relay, DC fail relay
trip circuit supervision relay, 3 phase over current overload,
under voltage, earth fault, 3 No's of 18KV, 10KA surge arrestors.
Breaker ON/OFF/Auto Trip Indication
Spring charged indication Lamps
Healthy Trip Indication
Phase Indicating Led Lamps for R Y B
TNC Breaker Control Switch
Push Button for Healthy Trip
Control Wiring
800 Amps Copper Bus Bar PVC Sleeved & required Panel Earthing
Common for Switchgear: MCBs for AC/DC Control, Heater with
Thermostat – ON/OFF Switch, Single Phase Switch Socket, Cubicle
Illu. TL Lamp, Door Switch , Fully covered Test Terminal Block etc.
M S Sheet Steel Enclosure for Outdoor Installation Powder coated
and with Siemens Grey Paint Finish
Provision for incoming and Outgoing cable entry provision excluding
cable glands and cable termination kit. Suitable provision for adding feeders
on either side of the breaker shall be provided.
Installation of breaker including unloading, storing, shifting, positioning and
assembly of any loosely supplied accessories such as cable boxes etc.
and touch-up painting if required. The work of installation shall be
complete with body earthing, cable terminations, control cabling, marshalling
box etc. as required. However all these items would be measured and paid
separately under various other items in this BOQ.
Provision for monitoring ON/OFF and trip status of breaker shall be provided for BMS
630 KVA TRANSFORMERS
Supply, Installation, Testing and Commissioning of out door type 22 / 0.433 KV, 630 KVA low loss (level 1) oil cooled transformer complete with first fill of oil, all accessories and components as per specifications. (to comply as per the latest IS1180.)
The transformer shall be provided with ON-load tap changing gear, free standing floor mounted RTCC panel with front door & all required accessories. Rate shall be inclusive of transportation, bottom mounting channels, foundation bolts with the following:
Paiint shall be suitable for coastal environment
Continuous rating : 630 KVA ONAN copper wound.
Service: Outdoor.
Mounting: Pad.
Wound: Double.
Type: Core.
Cooling: ONAN at 630KVA complete with natural air cooling system with radiators of adequate size.
Temperature rise in oil 40deg C.
Temperature rise in winding (by resistance method): + 45deg C.
Maximum ambient temperature: + 50 deg C.
Minimum ambient temperature: + 12 deg C.
Vector group : Dyn 11
Primary side connection: Delta
Primary side voltage: 22000 Volts
Primary side frequency: 50 Hz.
Primary Bushing: Porcelain / Epoxy or as per Client
Primary side Phases: 3
Primary side wires: 3
Secondary side connection: Star
Secondary side voltage: 433Volts
Secondary side wires: 4
Secondary side phases: 3
Secondary Bushing: Porcelain / Epoxy or as per Client
Primary voltage variation through ON-load tap changing gear with variation +5% and -15% in equal steps of 16 (Appx. 1.25%).
Type of loading: MIXED
Terminal on HV side: Cast Resin or Porcelain 22KV grade bushing suitable for 3C 240 Sqmm. 22KV XLPE (E) aluminium cable.
Terminal on LV side: Cast Resin 1100V grade bushing suitable for LV cables 4Rx3.5C 400SQ.mm aluminium armoured cable with 100%neutral.
Painting: Epoxy & Shade-632
Separate additional adaptor Box made up of 2mm CRCA sheet suitable to fix LT side and terminate LT cables as specified.
Standards:
As per IS 1180 and other authorities like local CEA /CEIG fire regulation, etc.
As per the technical specification but with the following accessories like LED lit annunciator with alarm & trip as shown in the SLD with Bucholz relay, Surge relay,MOG,Oil & Winding Temperature indicator with Alarm & Trip contacts, LV digital voltmeter in RTCC panel, Double Diaphragm Explosion Vent, etc. Including 3mm thick. stainless steel rating plate & terminal marking plate, lifting lugs, two earthing terminals with lugs, Thermometer pocket with suitable thermometer, jacking pads,
indicating type Silicagel Breather at 1350 mm from finished ground level, conservator tank with oil indicator, earthing (25x3mm) tinned copper or equivalent copper tinned type foils clips for main tank, top cover, OLTC tank & OLTC control mechanism box and marshalling box etc. independent pipe support for OLTC tank from ground level, under carriage fitted with flat bi-directional rollers, required transformer oil.
Regulation: Not more than 1.10% at OFF condition &
Not more than 2% at 0.8 P.F. at Full load.
Efficiency: Not less than 99.50% at 65% load.
Supplying, erecting and connecting Mush Room Type lockable push buttons
station with weather and water proof mounting box, interconnections etc. This unit has to be installed on the nearby wall near respective transformers.
HT CABLES
Supply, laying of 240 sq.mm. 3 core HT XLPE 22KV (E) Aluminium armoured cable in already excavted trench/ cable tray as per site condition.
Supply and termination of 240 sq.mm. 3 core HT XLPE 22KV (E) Aluminium armoured cable Outdoor Terminations kit.
Supply and termination of 240 sq.mm. 3 core HT XLPE 22KV (E) Aluminium armoured cable Indoor Terminations kit.
HT YARD FENCING & GATE
Supply and fixing of GI 75x75 mm 10 swg chain link mesh to the height of 1.8 meters above ground level and 330mm retaining wall with brickwork all around yard above ground level with vertical members of 50 x50 x 6 mm M.S angles at 1.5 meters intervel and tie angel at top with 25 x 25 x 6mm M.S angle.
Supply and fixing of 1.8mtr and 1.5 meters width gate made out of 50 X 50X 6 mm M.S angle cross supports fixed on 2mm thick 50mm dia GI pipe and covers with 50 x 50 mm weld mesh with pad locking arrangements.
Levelling of transformer yard with sand cussain of 75mm depth and 40mm blue metal and all required materials as per the standard and site condition.
LT PANEL ( Common Specification for all panels)
Supply, Installation,Testing, commissioning of LT panel suitable for 415V, 3 Phase, 50Hz, 4 wire system. Panel shall be Indoor type, floor mounted. Panels to be made up of 14SWG CRCA sheets painted RAL-7032 colour after seven tank pre-treatment process carried. Cable entry shall be provided as bottom entry. All incomers shall have segregation from outgoing cable chambers. 75mm height base channel to be provided at the bottom of all floor panels. Each door shall be casketed using rubber and hinged on each cubicle with insulated door knob. All feeders shall be identified by engraving names on GI sheet and screwed.
Bus bar shall be copper as specified and sized considering 1.2A/Sqmm(copper). Cross section of neutral bus shall be same as that of phase bus bar unless specified. Bus bar shall be suitably insulated with PVC heat shrinkable sleeves of suitable colour coding. Earth bus shall be provided as per standard. Interconnections shall be made with FRLS copper wire upto 63A and above rated shall be with busbar.
All MCCBs shall be provided with Rotary handles, spreades as required and shall be of thermal magnetic type protection upto 200A and above shall be of microprocessor type protection and Ics shal be of 100% Icu with faultcurrent capacity of 25kA upto 250 and above rated shall be of 36kA.
MAIN LT PANEL (OEM PANEL) ( Legrand)
EB Incomer-1&2 - 2 sets
1000A 50KA 4P EDO ACB with microprocessor based LSIg Protection.
shunt, UV & E/F release.
1000/5A CT for metering with MFM.
1000/5A CT for protection
1000/5A for APFC sensing.
Instrument cabin
RYBT, ON, OFF Indications. MFM with Demand controller
with 2 relay output to alarm hooter with reset.
Type (1+2) SPD with50kA 4P MPCB
Numerical Relay for OC/SC/E/F Protection.
TNC switch, Auxillary PFC contacts to receive external trip signals & Status
switch. Control MCBs.
DG Incomer - 1&2 -2 sets.
800A 50KA 4P EDO ACB with microprocessor based LSIg Protection.
shunt, UV & E/F release.
800/5A CT for metering with MFM.
Instrument cabin
RYBT, ON, OFF Indications. MFM
TNC switch, Auxillary PFC contacts to receive external trip signals & Status
switch.
BUS Coupler - 1 set
1250A 50KA 4P EDO ACB with microprocessor based LSIg Protection.
with ON, OFF, TRIP Indication. TNC, A/M & L/R switch.
Interlock & Changeover control
Complete with PLC with HMI based Interlocking system for automatic load balancing and load sharing options during power failure / changeover time
Outgoing
1000A 50kA EDO microprocessor based ACB with LSIg, shunt & UV - 4 nos. Auxillary PFC contact for BMS monitoring.
400A 36KA TP+N MCCB - 4Nos
200A 25KA TP+N MCCB - 2No
250A 25KA TP+N MCCB - 2No
All outgoing feeders shall be provided with Shunt coil CT, MFM With ON,OFF Trip indications. 2 Sets of PFC contact for BMS monitoring.
Busbar shall be tinned copper rate for 1250A TPN, 50kA for 1 sec. RFER SLD for Detail.
APFC PANEL with 7% Detuned Harmonic Filters (200 KVAR)
Supply, Installation,Testing, commissioning of LT panel suitable for 415V, 3 Phase, 50Hz, 4 wire system. Panel shall be Indoor type, floor mounted. Panels to be made up of 14SWG CRCA sheets painted RAL-7032 colour after seven tank pre-treatment process carried. Cable entry shall be provided as bottom entry. All incomers shall have segregation from outgoing cable chambers. 75mm height base channel to be provided at the bottom of all floor panels. Each door shall be casketed using rubber and hinged on each cubicle with insulated door knob. All feeders shall be identified by engraving names on GI sheet and screwed.
Incomer
630A, 36KA, FP MCCB with all connected accessories - 1No. as incomer.
Instrumental compartment
Outgoing: Total 200KVAR
Each capacitor bank (with 7% series reactor) in a separate compartment with necessary ventilation arrangements with wire mesh arrangements as required by the Electrical Authorities .
Ventilation fans shall be provided for all capacitor cabinsm
630Amps TPN 36kA Tinned Copper bus bars.
UTILITY PANEL
Supply, Installation,Testing, commissioning of LT panel suitable for 415V, 3 Phase, 50Hz, 4 wire system. Panel shall be Indoor type, floor mounted. Panels to be made up of 14SWG CRCA sheets painted RAL-7032 colour after seven tank pre-treatment process carried. Cable entry shall be provided as bottom entry. All incomers shall have segregation from outgoing cable chambers. 75mm height base channel to be provided at the bottom of all floor panels. Each door shall be casketed using rubber and hinged on each cubicle with insulated door knob. All feeders shall be identified by engraving names on GI sheet and screwed.
Incomer
200A 25kA TPN MCCB - 1 No with MFM, Shunt coil, RYBT indications.
Outgoing
63A 25kA TP+N MCCB - 6 Nos with ON,OFF indications.
FLOOR POWER PANEL ( GF-1,FF-1,SF-1,SF-1 = 4 Nos)
Supply, Installation,Testing, commissioning of LT panel suitable for 415V, 3 Phase, 50Hz, 4 wire system. Panel shall be Indoor type, floorl mounted. Panels to be made up of 14SWG CRCA sheets painted RAL-7032 colour after seven tank pre-treatment process carried. Cable entry shall be provided as bottom/top entry. All incomers shall have segregation from outgoing cable chambers. 75mm height base channel to be provided at the bottom of all floor panels. Each door shall be casketed using nitrile rubber and hinged on each cubicle with insulated door knob.
Bus bar shall be copper as specified and sized considering 1.2A/Sqmm(Copper). Cross section of neutral bus shall be same as that of phase bus bar unless specified. Bus bar shall be suitably insulated with PVC heat shrinkable sleeves of suitable colour coding. Earth bus shall be provided as required.
Incomer
400A 4P 25kA Motorized MCCB with controller - 2 No with RYBT indications.
Outgoing
250A 25kA TP+N MCCB - 4 Nos with ON,OFF indication
400A 3Ph 4W copper Bus bar with 100% Neutral.
SUB SWITCH BOARDS ( North & South) ( GF=1, FF-2,SF-2,TF-2 = 7 Nos)
Supply, Installation,Testing, commissioning of LT panel suitable for 415V, 3 Phase, 50Hz, 4 wire system. Panel shall be Indoor type, floor mounted. Panels to be made up of 14SWG CRCA sheets painted RAL-7032 colour after seven tank pre-treatment process carried. Cable entry shall be provided as bottom/top entry. All incomers shall have segregation from outgoing cable chambers. 75mm height base channel to be provided at the bottom of all floor panels. Each door shall be casketed using nitrile rubber and hinged on each cubicle with insulated door knob.
Bus bar shall be copper as specified and sized considering 1.2A/Sqmm(Copper). Cross section of neutral bus shall be same as that of phase bus bar unless specified. Bus bar shall be suitably insulated with PVC heat shrinkable sleeves of suitable colour coding. Earth bus shall be provided as required.
Incomer
250A 25kA TPN MCCB - 1 No with MFM & RYBT indications.
Outgoing
250A 3Ph 4W copper Bus bar with 100% Neutral.
SUB SWITCH BOARDS (South) ( GF=1 Nos)
Supply, Installation,Testing, commissioning of LT panel suitable for 415V, 3 Phase, 50Hz, 4 wire system. Panel shall be Indoor type, floor mounted. Panels to be made up of 14SWG CRCA sheets painted RAL-7032 colour after seven tank pre-treatment process carried. Cable entry shall be provided as bottom/top entry. All incomers shall have segregation from outgoing cable chambers. 75mm height base channel to be provided at the bottom of all floor panels. Each door shall be casketed using nitrile rubber and hinged on each cubicle with insulated door knob.
Bus bar shall be copper as specified and sized considering 1.2A/Sqmm(Copper). Cross section of neutral bus shall be same as that of phase bus bar unless specified. Bus bar shall be suitably insulated with PVC heat shrinkable sleeves of suitable colour coding. Earth bus shall be provided as required.
Incomer
250A 25kA TPN MCCB - 1 No with MFM & RYBT indications.
Outgoing
100A 25kA MCCB - 1 No
40A 25kA MCCB - 1 No
250A 3Ph 4W copper Bus bar with 100% Neutral.
LIFT PANEL
Supply, Installation,Testing, commissioning of LT panel suitable for 415V, 3 Phase, 50Hz, 4 wire system. Panel shall be Indoor type, floor mounted. Panels to be made up of 14SWG CRCA sheets painted RAL-7032 colour after seven tank pre-treatment process carried. Cable entry shall be provided as bottom/top entry. All incomers shall have segregation from outgoing cable chambers. 75mm height base channel to be provided at the bottom of all floor panels. Each door shall be casketed using nitrile rubber and hinged on each cubicle with insulated door knob.
Bus bar shall be copper as specified and sized considering 1.2A/Sqmm(Copper). Cross section of neutral bus shall be same as that of phase bus bar unless specified. Bus bar shall be suitably insulated with PVC heat shrinkable sleeves of suitable colour coding. Earth bus shall be provided as required.
Incomer
100A 4P 25kA Motorized MCCB with controller - 2 No with RYBT indications.
Outgoing
100A 3Ph 4W copper Bus bar with 100% Neutral.
HVAC PANEL-1&2
Supply, Installation,Testing, commissioning of LT panel suitable for 415V, 3 Phase, 50Hz, 4 wire system. Panel shall be Indoor type, floor mounted. Panels to be made up of 14SWG CRCA sheets painted RAL-7032 colour after seven tank pre-treatment process carried. Cable entry shall be provided as bottom/top entry. All incomers shall have segregation from outgoing cable chambers. 75mm height base channel to be provided at the bottom of all floor panels. Each door shall be casketed using nitrile rubber and hinged on each cubicle with insulated door knob.
Bus bar shall be copper as specified and sized considering 1.2A/Sqmm(Copper). Cross section of neutral bus shall be same as that of phase bus bar unless specified. Bus bar shall be suitably insulated with PVC heat shrinkable sleeves of suitable colour coding. Earth bus shall be provided as required.
Incomer
400A 4P 25kA Motorized MCCB with controller - 2 No with RYBT indications.
Outgoing
100A 25kA TP+N MCCB - 1 No
63A 25kA TP+N MCCB - 6 No
40A 25kA TP+N MCCB - 9 No
32A 25kA TP+N MCCB - 2 No
ON,OFF, TRIP indication
400A 3Ph 4W copper Bus bar with 100% Neutral.
STREET LIGHT PANEL
Supply, Installation,Testing, commissioning of LT panel suitable for 415V, 3 Phase, 50Hz, 4 wire system. Panel shall be Indoor type, floor/wall mounted. Panels to be made up of 14SWG CRCA sheets painted RAL-7032 colour after seven tank pre-treatment process carried. Cable entry shall be provided as bottom/top entry. All incomers shall have segregation from outgoing cable chambers. 75mm height base channel to be provided at the bottom of all floor panels. Each door shall be casketed using nitrile rubber and hinged on each cubicle with insulated door knob.
Bus bar shall be copper as specified and sized considering 1.2A/Sqmm(Copper). Cross section of neutral bus shall be same as that of phase bus bar unless specified. Bus bar shall be suitably insulated with PVC heat shrinkable sleeves of suitable colour coding. Earth bus shall be provided as required.
Incomer:
63A 25kA FP MCCB with Thermal Magnetic Release - 1 No.
Digital type ELR with suitable Wound CBCT 1 No.
MFM with 63/5A class 1.0 Resin CT - 1 No and RYB indications - 1Set
Street light controller for automatic ON & OFF operations.
Outgoing:
32A TP MCCB - 4 Nos
ON,OFF indication
63A 3Phase 4 wire Copper Bus with 100% Neutral Bus.
DG SYNCHRONIZATION PANEL
Supply, Installation,Testing, commissioning of LT panel suitable for 415V, 3 Phase, 50Hz, 4 wire system. Panel shall be Indoor type, floorl mounted. Panels to be made up of 14SWG CRCA sheets painted RAL-7032 colour after seven tank pre-treatment process carried. Cable entry shall be provided as bottom/top entry. All incomers shall have segregation from outgoing cable chambers. 75mm height base channel to be provided at the bottom of all floor panels. Each door shall be casketed using nitrile rubber and hinged on each cubicle with insulated door knob.
Incomer
800A 50KA 3P EDO microprocesor based LSIg ACB - 2 Nos + 400 A capacitor duty contactor - 2 Nos
Instrument cabin
DG Synchronizing relay - 1 set.
Revers Power Relay, SC,OC,E/F Relay
RYBT, ON, OFF Indications. MFM
TNC switch, Auxillary PFC contacts to receive external trip signals & Status
switch.
Outgoing
800A 50KA 4P EDO microprocesor based LSIg ACB - 2 Nos.
Instrument cabin
RYBT, ON, OFF Indications. MFM
TNC switch, Auxillary PFC contacts to receive external trip signals & Status
switch.
1600A 3Phase 4 wire Copper Bus with 100% Neutral Bus.
SUB STATION PANEL
Supply, Installation,Testing, commissioning of LT panel suitable for 415V, 3 Phase, 50Hz, 4 wire system. Panel shall be Indoor type, floor/wall mounted. Panels to be made up of 14SWG CRCA sheets painted RAL-7032 colour after seven tank pre-treatment process carried. Cable entry shall be provided as bottom/top entry. All incomers shall have segregation from outgoing cable chambers. 75mm height base channel to be provided at the bottom of all floor panels. Each door shall be casketed using nitrile rubber and hinged on each cubicle with insulated door knob.
Bus bar shall be copper as specified and sized considering 1.2A/Sqmm(Copper). Cross section of neutral bus shall be same as that of phase bus bar unless specified. Bus bar shall be suitably insulated with PVC heat shrinkable sleeves of suitable colour coding. Earth bus shall be provided as required.
Incomer
63A 25kA FP MCCB with Thermal Magnetic Release - 1 No.
Digital type ELR with suitable Wound CBCT 1 No.
MFM with 63/5A class 1.0 Resin CT - 1 No and RYB indications - 1Set
Outgoing
32A 25kA TP MCCB - 4 Nos
63A 3Ph 4W copper Bus bar with 100% Neutral.
PUMP PANEL
Supply, Installation,Testing, commissioning of LT panel suitable for 415V, 3 Phase, 50Hz, 4 wire system. Panel shall be Indoor type, floor/wall mounted. Panels to be made up of 14SWG CRCA sheets painted RAL-7032 colour after seven tank pre-treatment process carried. Cable entry shall be provided as bottom/top entry. All incomers shall have segregation from outgoing cable chambers. 75mm height base channel to be provided at the bottom of all floor panels. Each door shall be casketed using nitrile rubber and hinged on each cubicle with insulated door knob.
Bus bar shall be copper as specified and sized considering 1.2A/Sqmm(Copper). Cross section of neutral bus shall be same as that of phase bus bar unless specified. Bus bar shall be suitably insulated with PVC heat shrinkable sleeves of suitable colour coding. Earth bus shall be provided as required.
Incomer
250A TP+NL 25kA MCCB with MFM & CBCT ELR - 1 No
Outgoing
6A, TP MPCB , Contactor, OLR, ON,OFF push button indication - 6 Nos.
16A, TP MPCB , Contactor, OLR, ON,OFF push button indication - 4 Nos.
125A 25kA TP MCCB - 2 Nos
STP PANEL
Supply, Installation,Testing, commissioning of LT panel suitable for 415V, 3 Phase, 50Hz, 4 wire system. Panel shall be Indoor type, floor/wall mounted. Panels to be made up of 14SWG CRCA sheets painted RAL-7032 colour after seven tank pre-treatment process carried. Cable entry shall be provided as bottom/top entry. All incomers shall have segregation from outgoing cable chambers. 75mm height base channel to be provided at the bottom of all floor panels. Each door shall be casketed using nitrile rubber and hinged on each cubicle with insulated door knob.
Bus bar shall be copper as specified and sized considering 1.2A/Sqmm(Copper). Cross section of neutral bus shall be same as that of phase bus bar unless specified. Bus bar shall be suitably insulated with PVC heat shrinkable sleeves of suitable colour coding. Earth bus shall be provided as required.
Incomer
125A TP+NL 25kA MCCB with MFM & CBCT ELR - 1 No
Outgoing
6A, TP MPCB , Contactor, OLR, ON,OFF push button indication - 6 Nos.
16A, TP MPCB , Contactor, OLR, ON,OFF push button indication - 4 Nos.
LT CABLE
Supply of 1.1kV grade LT PVC insulated, cores laid up, PVC tape inner sheathed, GI wire/strip armoured, extruded PVC Tape type ST2 outer sheathed aluminium/copper (multistranded) conductor cables of following sizes. Rate shall be same for laying on trays, clamping on wall and laying in trench.
4Cx 6sq.mm Aluminium
4Cx10sq.mm Aluminium
4Cx16sq.mm Aluminium
4Cx25sq.mm Aluminium
3.5Cx50sq.mm Aluminium
3.5Cx185sq.mm Aluminium
3.5Cx300sq.mm Aluminium
3.5Cx400sq.mm Aluminium
12Cx2.5 Copper cotrol cable
4Cx2.5 Copper cotrol cable
CABLE END TERMINATION
Supply & terminating the ends of cables of following sizes using Siemens type single compression cable glands, crimping type Aluminium / Copper lugs of required size, crimping paste, tapes, bolt & nuts, double washers, spring washers, gland earthing clips and 22SWG bar copper wire, etc. complete.
Each cable shall be identified with cable tags above the panel / DB. Cable shall be properly dressed before termination and bent at an angle of 15 times the radius of the cable. No extra holes shall be made on top of the panel and if any made, shall be sealed properly. The final tightness at every terminal shall be done with a torque wrench and tightened up to the recommended level.
4Cx 6sq.mm Aluminium
4Cx10sq.mm Aluminium
4Cx16sq.mm Aluminium
4Cx25sq.mm Aluminium
3.5Cx50sq.mm Aluminium
3.5Cx185sq.mm Aluminium
3.5Cx300sq.mm Aluminium
3.5Cx400sq.mm Aluminium
12Cx2.5 Copper cotrol cable
4Cx2.5 Copper cotrol cable
RISING MAINS & BUS DUCT
Supply of 3P+100% Neutral 4W 1000A Copper Conductor Sandwich Design Rising Mains with External Aluminium earthing of 25/3.2mm 2runs. Enclosure is 1.6mm Galvanised Iron. Busduct is designed based on Temp Rise only not as per Current density. (Ambient 40 Deg C + rise 55 Deg C)
Supply & Fixing of Terminal flange
Supply & Fixing of End cover
Supply & Fixing of Copper Flexible
End Feed Unit with 4P 50kA 1000A EDO Based ACB (Inclusive of End Cover & Cable adaptor Box)
Plug in Box with TP 25kA 100A TM Based MCCB
Plug in Box with TP 36kA 400A TM Based MCCB
Supply & Fixing of support Brackets
Supply & Fixing of Spring support Brackets
Supply & Fixing of Wall support Brackets
25x3mm Aluminium flat for body earth
Supply & fabrication of MS support materials
DISTRIBUTION BOARDS
Supply, installtion testing and commissioning of VERTICAL THREE PHASE DISTRIBUTION BOARD WITH MCBS 8 way vertical TPMCB sheet steel distribution boards flush type / surface type fitted with bus bars and neutral links with single / three phase MCB outgoings and separate 4 way provision for accommodating One No. 4 pole incoming MCB and another separate 4 way provision for accommodating One No. 4 pole ELCB / RCD with label holder and provisions for taking up cable for size not less than 35 sq.mm. Wth Metal Door Cover with IP42 Protection
HIGHER END
63A Triple Pole MCCB - 1 No
63A 100 mA RCCB - 1 No
Triple Pole 6A to 32A,10KA - 6Nos
Single Pole 6A to 32A, 10KA -6 Nos
Supply, installtion testing and commissioning of VERTICAL THREE PHASE DISTRIBUTION BOARD WITH MCBS 6 way vertical TPMCB sheet steel distribution boards flush type / surface type fitted with bus bars and neutral links with single / three phase MCB outgoings and separate 4 way provision for accommodating One No. 4 pole incoming MCB and another separate 4 way provision for accommodating One No. 4 pole ELCB / RCD with label holder and provisions for taking up cable for size not less than 35 sq.mm. Wth Metal Door Cover with IP42 Protection
HIGHER END
63A Triple Pole MCCB - 1 No
63A 100 mA RCCB - 1 No
Triple Pole 6A to 32A,10KA - 6Nos
Single Pole 6A to 32A, 10KA -6 Nos
Supply, installation, testing and commissioning of SINGLE PHASE DISTRIBUTION BOARD WITH MCBs 12 way vertical SPMCB sheet steel distribution boards flush type / surface type fitted with bus bars and neutral links with single phase MCB outgoings and separate 2 way provision for accommodating One No. 2 pole incoming MCB / Isolator and another separate 2 way provision for accommodating One No. 2 pole ELCB / RCD with label holder and provisions for taking up cable for size not less than 35 sq.mm.
SPMCB DB with Metal Door Cover with IP42 Protection HIGHER END
Double Pole 40A, 10KA
Single Pole 6A to 32A, 10KA -10 Nos
2 pole sheet steel enclosure with Double Pole 6A to 32A, 10KA
4 pole sheet steel enclosure with Four Pole 6A to 32A, 10KA
4 pole sheet steel enclosure with Four Pole 32A to 100A, 10KA
Supply, installation, testing and commissioning of HORIZONTAL THREE PHASE DISTRIBUTION BOARD WITH MCBS
6 way TPMCB sheet steel distribution
boards flush type / surface type fitted with bus bars and neutral
links with single / three phase MCB outgoings and separate 4
way provision for accommodating One No. 4 pole incoming MCB
/ Isolator and another separate 4 way provision for
accommodating One No. 4 pole ELCB / RCD with label holder
and provisions for taking up cable for size not less than 35
TPMCB DB with Metal Door Cover with IP 42 Protection
HIGHER END
Triple Pole & Neutral 63A, 10KA
63A 100 mA RCCB - 1 No
Triple Pole 6A to 32A,10KA- 3 Nos
SP 6A-32A, 10kA - 6 Nos
POINTS WIRING
Supply, installation, testing of 3R x 1.5 sqmm multi stranded copper FRLSH insulated flexible wires including 25mm dia MS conduit and accessories for same. All fixing accessories are inclusive such as clamps, screws, slotted channel, thread rod, junction boxes, pull through box, flexible hose, cast ironhose glan, connector etc.. as required. Point wiring Rate shall include 6A switch, faceplate and back box, etc, complete. for primary point from switch board to first light point.
Supply, installation, testing of 3R x 1.5 sqmm multi stranded copper FRLSH insulated flexible wires including 25mm dia MS conduit and accessories for same. All fixing accessories are inclusive such as clamps, screws, slotted channel, thread rod, junction boxes, pull through box, flexible hose, cast ironhose glan, connector etc.. as required for Secondary point from first light to second light point and so on.
Wiring with 3 x 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor cable of 1100V grade on suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with MS switch box and 5A FT switch (two way) with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for open staircase light point
Supply, installation, testing of 3R x 1.5 sqmm multi stranded copper FRLSH insulated flexible wires including 25mm dia MS conduit and accessories for same. All fixing accessories are inclusive such as clamps, screws, slotted channel, thread rod, junction boxes, pull through box, flexible hose, cast ironhose glan, connector etc.. as required from MCB to first light point.
Lift Shaft Wiring : Wiring, Connecting, Testing & Commissioning for lift well light point and 6Amps power socket outlet for all 4 floors with 2 x 1.5 sqmm FRLS PVC insulated stranded copper conductor of 1100V grade along with 1 x 1.5 sqmm FRLS PVC insulated standed copper conductor cable as earth wire in MS conduit including providing and fixing switch box, 2 Nos. of 5A single way flush type switch (for controlling light point and socket Outlet ) for each floor of the lift well , 1 No. 5A 5 Pin shuttered socket outlet with flush type switch for each floor of the lift well and making necessary connections complete etc
SOCKETS
Supply and fixing of 1 no.6A two module 5 pin socket , 1 no. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections.
Supply and fixing of 3nos.6A two module 5 pin socket , 3nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End
Supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections.
Supply and fixing of 20A DP Switch With indicator(2M) 20Amps 3 Pin Socket With Shutter Type , combined flush type wall socket FOR Split AC unit UNIT in switch along with moulded front plate in G.I anodised manufaturer's mounting box fixed flush with the wall complete with all accessories as required as per the site condition.
Supply and fixing of 32A 3P+N+E surface mount industrical socket and suitable 32A plug with accessories. Similar to tempra model
MAINS WIRING
Supply and Run of 2 of 1.5 sq.mm. (36/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable MS pipe Concealed/open in wall and ceiling with continuous earth wire connection by 1.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour.
Supply and Run of 2 of 2.5 sq.mm. (36/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable MS pipe Concealed/open in wall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour.
Supply and Run of 2 of 4 sq.mm. (36/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable MS pipe Concealed/open in wall and ceiling with continuous earth wire connection by 4 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour.
Supply and Run of 4 of 6 sq.mm. (84/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable MS pipe on wall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire with painting of suitable colour.
Supply and Run of 4 of 10 sq.mm. (140/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable MS pipe on wall and ceiling with continuous earth wire connection by 4 sq.mm. PVC insulated SC unsheathed copper wire with painting of suitable colour
Supply and Run of 2 of 2.5 sq.mm. (36/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour.
EMPTY CONDUIT
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
25mmdia
Supplying and fixing of following sizes of medium class Electrical grade black enamel MS conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
25mmdia
LIGHT FITTINGS
Supply and fixing 4 feet 18W Crystal Glass LED Tube Light with TW round Blocks on wall or ceilling with flu tube with PVC unsheathed copper leads from terminal to the fitting.
Supply and Fixing of WT bulk Head Fitting With Guard with suitable for 9W CFL / LED lamp and giving connection
Supply and fixing of LED 15W Recess mount down light fitting with all accessories
Supply and fixing of LED 15W Surface mount down light fitting with all accessories
Supply and fixing of LED 36W Recess mount 2'x2' light fitting with all accessories
supply and fixing of 60W LED street light fitting with LED (Higher end) with 25 mm dia. GI pipe (class B) with 1 no. 25 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting
Supply and fixing of 80W focus light fitting with LED and support accessories as required. For Entrance arch
supply and fixing of 65 mm dia. (2 -1/2") GI pipe (class B) of 6 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting with construction of masonary pedestal with suitable SMC box with door arrangement to house 6A SP MCB switch, 2/4 way connector on suitable hylem sheet and supply and fixing of 60W LED street light fitting with LED (Lower end) with 1 metre 32mm dia. GI pipe (class B) Complete with suitable MS clamps for LED steet light fitting and SMC box with PVC unsheathed copper leads from SMC box to fitting and with painting of suitable colour .
Supply and fixing of 1200 mm (48") AC ceiling fan complete with out regulator and 1000mm down rod on the including fan clamp with side plates and cross arm of size 450mm (18")
Supply of high quality integrated LED posttop/gatelight Luminaire with a system lumen of 4500Lm and system wattage between 45W with an efficiency 100lumen/watt.
7W, 200lumen, P65/IK10 LED bollard with base plate.
14W/mtr LED Strip light with suitable driver.
EARTHING
Supply & Fixing of ASHLOK’S Pipe - In - Pipe Technology | Designed & Manufactured using M.S Pipes | Outer Dia is 76 mm with a wall thickness of 1.6 mm | Inner Dia is 42 mm with a wall thickness of 2.6 mm | Over all Length is 3000 mm | External Corrosion Protection : Carbon Coated (100+ microns) | Internal Corrosion Protection : A groundbreaking corrosion resistant Crystalline Conductive Compound is filled and compacted in the cavity within the pipes to enhance the electrodes performance. Rate shall include mixture of back fill Compounds Conductolite|25, Terraion|10 and heavy duty cover EPCC BIG, 450x450mm chamber with 230mm wall brick work, platering etc. complete as required at site. for Body earthing & LA earthing).
Supply, installation of Copper Plate earth electrode station using 600 x 600 x 3.15mm Copper plate with 50mm dia. 3mtr long GI pipe with watering funnel, 2Rx25x6mm Copper strip as vertical run, connecting top clamp, etc., complying to IS 3043 in all respects with excavation in all types of soil, filling with earth enhancing compound material. The rate shall inlcude of chamber constructed with 450mmx450mm with depth of 600mm using125mm brick work finished with plastering and 450mm x 450mm x 10mm cast iron cover with frame. The Cover shall be heavy duty to suit heavy vehicle movements. (Transformer & DG neutral earthing)
Supply and fixing 8 SWG copper wire for for earthing.
Supply and run of 25mm x 3mm copper flat with necessary clamps / Supports on wall / floor / ground for equipment body earth connection.
Supply and run of 50mm x 6mm copper flat with necessary clamps / Supports on wall / floor / ground for Neutral earth connection for Transformer & DGs
Single core 6 Sqrmm FRLS copper flexible cable in PVC conduit.
i) Air terminals
II) Support System for ar terminals.
III) Copper Conductor from Air terminal to earth pit with support accessories complete.
DG SETS
Supply, Erection, Testing, Commissioning and Handing over of 1 No 500KVA Diesel Generator set of 0.8P.f, Three Phase, 415/420Volts, 50c/s, 1500RPM as detailed below 1.ENGINE: Water cooled Diesel engine suitable for generator application with a shaft Output of 1200 BHP at 1500 RPM under NTP Condition as per BSS 5514/IS 10000. The engine shall comprise the following standard scope of supply: (Make Kirloskar/ Cummins/ Ashok Leyland/ Greaves/Equivalent)
1. Dry type Air cleaner 2. Expansion bellow 3. Radiator, Radiator fan and mounting 4. Air to air charge cooler 5. Exhaust Gas turbo charger 6. Lube oil cooler and Lube oil filter 7. Fuel filter(pre and micro) 8. In-line Mono-block fuel injection pump with governor and fuel feed pump 9. Electronic governor 10. 24V Battery charging alternator 11. 24V Volt electric starter motor 12. Engine test Certificate 13. Residential Mufler 14. Fly wheel with starter ring.
ENGINE INSTRUMENTPANEL MOUNTED. Engine control panel consisting of ON/OFF/START Key Lube oil pressure guage , oil temperature gauge, high water temperature guage and electronic hour meter and RPM indicator. SAFETY SYSTEM OF ENGINE :-The Engine shall trip for the following conditions with visual alarm device 1. Low lubricating oil pressure 2. High Water temperature 3. Vee-belt failure and over speed 4. The visual indicator should be provide for Low battery indication. The engine should be capable of providing 10% over load for one hour for every 11 hours continuous running at full load.
2. ALTERNATOR : Alternator capacity of 500 KVA/ 400 KW,AC 3 phase, 50HZ, 415/420V, 0.8P.F.4 wire self excited, self regulated designed to run at 1500 RPM under NTP conditions confirming to BS 5000/ IS 13364 (part-II) 1992 to be coupled directly to the Diesel engine and test certificate (Make: Kirloskar/ Crompton/ Greaves/ CAT/Equivlent.) 3.ACOUSTIC ENCLOSURE:- Acoustic enclosure shall be powder coated and fabricated of 16 SWG CRCA MS sheet.The silent canopy shall be of nut bolt type construction. Critical processes of punching are done on CNC Machine to maintain dimensional accuracy of hole
within 0.1mm Powder coating done after seven – tank surface preparation process of sheet metal. Canopy panel and doors shall have inside lining of FIRE RETARDANT 64 Kg/m density mineral wool of 100mm thickness as Acoustic material. Four hinged doors shall be provided to canopy. The average sound level at 1 Mt distance shall be less than 75 DBA average or as per CPCB norms. Surface treatment – Painting: The enclosure surface shall be suitably treated for degreasing de-rusting and posphating. The canopies are passed through seven – tank treatment thoroughly. Additional features of canopies: Canopy fabricated on CNC machines with dimensional accuracy of 0.1 mm so as to increase its durability. Special designed supporting rips/structures are used in canopies so as to give sturdiness and to reduce the vibrations of the DG sets if any World class Cooling package:
Canopies shall have cooling package for which it can also perform at 45 degree C/ambient temperature.No grouting required on the ground, only a level surface capable of with standing the DG weight.Lifting hooks shall be provided for the acoustic enclosure, which should be unloaded independently of the DG set. 1150.00 30250.00 The Gen set frame shall also be provided with hooks for unloading Temperature rise inside the canopy: Canopies shall be designed so as to maintain the temperature difference between ambient and air inlet at cleaner within the enclosure well within 5-7 deg centigrade.
BASE FRAME : The base frame should be fabricated in sheet metal. The base frame is rugged in construction and designed for mounting engine and brush less alternator closely coupled, with cross members mounted on AVM. The base frame shall be have provision for mounting of acoustic enclosure on it. The supply of generator set includes loading. Unloading and transportation charges. 6. Battery: 2 Nos 12V 180AHR Battery.
DG EXHAUST STACK
Dia 10" / 250mm, MS ERW B Class Pipe. Shall be duly cleaned with Wire Brush and Coated with 1 coat of Primer & 2 coats of Heat Resistant Paint -2 x 500 kva
Exhaust pipe Thermal Insulation and cladding for 10"dia pipe, using Rockwool Insulation of density 64Kg/m3 with 50mm thick bound with GI chicken wire mesh & Cladding using 24 SWG Aluminium sheet - 2 x 500 kva
Installation of Silencer - 2 x 500 kva
Thermal Insulation and cladding of Silencers, using Rockwool Insulation of density 64Kg/m3 with 50mm thick bound with GI chicken wire mesh & Cladding using 24 SWG Aluminium sheet - 2 x 500 kva
10" SS Flexible Bellows with Table D Flanges, Gaskets and Hardwares - 2 x 500 kva
M.S Structural Supports using ISA / ISMC. Supports shall be Duly Cleaned with Brush follwed by One Coat of Primer and Two Coats of Synthetic Enamel Paint / Aluminium Paint- Whever MS supports required for the BOQ items to be considered from this line item at actualsm
Lightning Arrestor - Convetional - Spike and Sphere Type - Hex make
25 x 3 CU Strip for LA earthing with insulators
Aviation Lamp - LED Type- Bajaj Make
3C x 2.5 sq.mm 1.1 KV XLPE, Cu.Ar.Multistrand Cable
End Termination for the above Cable
CABLE TRAY & MISCELLANEOUS
Perforated type GI cable tray made up of 2.0mm Thick GI sheet with 1.6mm GI tray cover on top with fixing accessories like fasteners, threaded down rods, slotted c channel etc.. Colour shall be as per approval.
450 mm Width x 75 mm Height x 1.5mm thickness
300 mm Width x 50 mm Height x 1.5mm thickness
200 mm Width x 50 mm Height x 1.5mm thickness
100 mm Width x 50 mm Height x 1.5mm thickness
Supply,Testing and Commissioning of 5 KVA three phase in & three phase output, Double conversion Online UPS system with SMF Batteries back up for 2 hours and suitable MS Rack to accommodate the batteries externally,Open Rack,Dc cable 5mts, Interlinks and breaker etc as required
Liaison with the Electrical Inspector to Govt., / CEA for preparation of Working drawings etc., obtaining approval for drawing. Preparation of completion Report. Arranging for inspection and attending to defects report and preparation of as fitted drawings and obtaining safety certificate from CEIG / CEA.
Hand Gloves 11KV Grade
2m x 1m Rubber Mat suitable for 11 KV installation confirming to IS
Shock Treatment Chart fixed in glass frame
First Aid Box complete with all First Aid Medicines
AC Chargeable Emergency Lamp 2 x 11W PL Lamp with all connected accessories
Earth Discharge Rod
Danger Board as required by the Electrical Authorities
Labour charges for fixing of above safety appliances
Supplying & contruction of Electrical cable chambers comprising burnt brick/solid block masonry walls of 100 mm thk., built in CM 1:4 over M-15 CC bed of thickness 100 mm, Heavy duty RCC precast cover (SFRC), benching in CC M-15, internal faces plastered smooth in CM 1:4, 15mm thick and outside Rough Plastered with CM 1:6, 15mm thick including necessary earth work excavation returning and refilling and disposing surplus soil as directed by the Engineer in charge.
a) 600mm(W) x 600mm(L) with 1000mm depth
a) 1000mm(W) x 1000mm(L) with 1000mm depth
Supply and laying of 300mm Dia HDPE pipe for road crossing. Rate shall include earth excavation and refilling of soil as required at site.
LT Cable trench - Excavation and backfilling of the sand trench along the side of the road. The trench shall be 1000mm deep 450mm wide. The bottom shall be filled one layer of 75mm fine river sand and cables shall be laid on top of it. On the laid cables one more layer of 75mm thick river sand , underground utility marking tape (ESB marker red color PVC tape shall be laid on top of it without any gap. The trench shall be backfilled, watered and rammed to suit original level.
SOLAR PV PLANT
On Grid Solar PV Plant comprising of:
i) Solar panels of type Mono Crystline, PERC, etc.
ii) Power Conditioning Unit (PCU)with MPPT, Inverter, Controls, Protection Devices, Interconnecting D.C. cables, Connectors, Junction Boxes and accessories.
iii) D.C. D.B
iv) A.C. D.B
v) A.C. cables and accessories
vi) Lightning arrestor, earthing, etc.
vii) Module Metallic Mounting Structures
viii) Installation, Testing and Commissioning corresponds to BIS and IEC requirements
LIFT / ELEVATORS
Supply, erection , testing and Commissioning of Machine Room Less Lift of 20 Person capacity having 4 Stops for G + 3 Floor of 4 M travel distance between floors in LIFT Well size of 2400 X 2500 mm including Floor level indicators in each floor, False ceiling with Light, Mirror and wall finish of SS Grade 304 Hairline finish, Brushed SS Handrail for rear wall , Door having SS Brush finish , Car Floor , call indicators in each floorsetc ;.
Supply, erection , testing and Commissioning of Machine Room Less Lift of 16 Person capacity having 4 Stops for G + 3 Floor of 4 M travel distance between floors in LIFT Well size of 2250 X 2400 mm including Floor level indicators in each floor, False ceiling with Light, Mirror and wall finish of SS Grade 304Brushed finish, Brushed SS Handrail for rear wall , Door having SS Hairline finish etc ;.
HEAT, VENTILATION & AIR CONDITIONING
Supplying, installation, testing and commissioning of VRF Outdoor units consists of 100% inverter scroll compressor / Twin Rotary compressors, DC fan motor with aero-spiral fan blade, e-pass heat exchanger, safety valves, solenoid valves, receiver, capillary tube, check valve, electronic expansion valve, high pressure switch, low pressure sensor, pressure regulating valve, refrigerant filter, stop valve, accumulator and refnet kits.The Rate shall be inclusive of R-410A refrigerant & oil pre charging, vibration isolators, supports, necessary foundation / pedestal works, elbow duct/cowl piece, suitable power cable from isolator to VRF ODU each module (7.5 RMT) etc.. The VRF ODU shall be compatible for BMS integration. All units shall be provided with necessary accessories to mutually communicate with the BMS System to be integrated with the BMS for the necessary monitoring and control.
The below mentioned ODU capacities are the minimum Cooling Capacity required at the following conditions a. 100% load condition b. 42 degC ambient condition c. All IDUs are in operating condition d. Design indoor temperature - Office area : 23 degC. RH shall not exceed 60%. The vendor to propose the suitable ODU considering the ambient deration. The VRF data sheet & ISEER data sheet shall be filled and submitted by the Vendor with the proposed VRF ODU capacity. The proposed VRF ODU capacity shall be approved by Client & Consultant before procurement.
Below Mentioned more than 18 HP ODU Models should be able to make module combination
(Approved Makes : Daikin,Hitachi,Toshiba)
6HP VRF ODU ( SIDE DISCHARGE )
8HP VRF ODU
10HP VRF ODU
12 HP VRF ODU
14 HP VRF ODU
20 HP VRF ODU
28 HP VRF ODU (14HP + 14 HP)
36 HP VRF ODU (18HP + 18 HP)
Supplying, installation, testing and commissioning of Ceiling Suspended Duct Type Metallic body BMS Compatible VRF Indoor air conditioning units with direct driven fan, Evaporator coil, high efficient filter, inbuilt microprocessor thermostat, electronic expansion valve, remote, provision of fresh air duct connection, drain pumps for casette, necessary ceiling supports & vibration isolators, R410A refrigerant charging, Refnet joints (Refrigerant branch kit) for both liquid and gas line branch kits, oil charging, power cabling from nearest socket(7.5 RMT), control wiring and drain connection, etc. All units shall be cpable of mutually communicating with the BMS so that all can be integrared with the BMS System for monitoring and control.The below capacity units are OEM units and the capacity are as mentioned below:- Approved Makes : Daikin,Hitachi,Toshiba
3.2 TR - ESP 20mm
4.8 TR - ESP 20mm
6.4 TR - ESP 20mm
8.0 TR - ESP 20mm
SITC of Double Skin Floor mounted Air Handling Units as per the specifications. The AHU shall be 45±5mm thick panel with PUF insulation, thermal break profile, filter section with MERV 8, min 4 row deep DX Cooling coil of copper tube & aluminium fins, copper header, DIDW fan with motor& suitably rated VFD, limit switch, light, inspection glass, spring vibration isolator for fan and motor, factory assembled volume control damper, internal power and control wiring, required length of power cable from the panel to the equipment, GI base frame complete as per specification required. AHU noise level shall be less than 65dBA at 1.5m distance. Fan motor shall be suitable for 415±10% volts, 50 cycles, 3 phase AC supply.
The AHU shall be provided with suitable rating starter panel and components. The electrical panel shall have incoming breaker, single / Multiple outgoing breakers, speed controler, indication lamp, contactor, auto / manual switch, necessary relays, potential free contacts to be interlocked with fire alarm control module to trip the AHU incase of fire. The electrical starter panel shall have necessary relay, and potential free contacts for the following BMS provisions : (1) Auto / Manual command, (2) Auto/ Manual / OFF status, (3) Run status, (4) Trip Status. (Make : VTS / Flaktwood / Edgetech /System Air / luftec)
Capacity: 22 TR, Dehumidified Air: 12000 CFM, ESP: 40mmWC,
Capacity: 16 TR, Dehumidified Air: 9000 CFM, ESP: 40mmWC,
Capacity: 11 TR, Dehumidified Air: 4400 CFM, ESP: 40mmWC,
Supply, installation, testing and commissioning of Valve Kit for AHU & CSU
Supply, installation, testing, and commissioning of Imported fittings Y-joints, distributor and headers for all Indoor units as per layout drawings.
SITC Main controller BMS interface Modbus /bacnet IP for thrid party system integration,software and licence key,communication cables, basic functions like ON/OFF, mode settings, temperature setting, fan speed setting, louver setting, timer, scheduling, holiday mode setting, error code, alarm, emergency trip, sensors etc.
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable size cable tray/adjustable ring type hanger supports, jointing/brazing including accessories, insulated with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines & cladded with 26G aluminium sheet. all accessories as per specifications etc. as required
All connections of Refrigerant piping shall be in high grade Copper of Refrigeration quality with Eddy Current Testing and material test Certificates.
For individual Piping 50 / 100 mm wide Aluminium Tape shall be used at joints of Piping with Bands for identification.
25.4 mm O.D. (insulation : 19 mm)
22.2 mm O.D. (insulation : 13 mm)
19.1 mm O.D. (insulation : 13 mm)
15.9 mm O.D. (insulation : 13 mm)
12.7 mm O.D. (insulation : 13 mm)
9.5 mm O.D. (insulation : 13 mm)
6.4 mm O.D. (insulation : 13 mm)
Supply,installation,testing and commissioning of UPVC drain piping complete with fittings, supports as per specifications and duly insulated with 9 mm thick closed cell elastomeric nitrile rubber or XLPE cladded with 26G aluminium sheet.
Supplying, installing, testing and commissioning of Shielded control cum transmission wiring of 2 core x 1.5 sqmm copper FRLSH, XLPE insulated cable in suitable GI conduits accessories between indoor and outdoor units. Necessary securing of conduit shall be made by contractor. After completion of work wall and floor shall be repaired and brought to its original finish. The rate will also include cost of laying of GI conduit between indoor and outdoor units.
2C x 1.5 Sq mm (Unarmoured)
Providing additional R410A gas charging for the ODU units
Supply and Installation of Hot dipped galvanized / Powder coated type perforated type Cable trays of following sizes, suspended from ceiling or fixed vertically on wall / column as per including necessary supports like anchor bolts, etc., and accessories like Elbows, Bends, Tee, required support / suspenders, hardware etc. as per site requirements. All the supporting structure & hardware including nuts & bolts and shall be of galvanized iron as approved. Height of cable tray will be 50mm and all the elbows, Bends, Reducers, Tees should be factory made. 'Ladder Tray is 2mm Thickness and Perforated Tray is 1.6mm Thickness
100mm wide 50mm height -Perforated acble tray
150mm wide 50mm height -Perforated acble tray
300mm wide 50mm height -Perforated acble tray
450mm wide 50mm height -Perforated acble tray
Supply, installion, testing and commissioning of Inverter type DX coil Hi Wall Split Type Air-conditioning Unit (indoor). Indoor unit shall be complete with evaporator cooling coil, Pre-filter, DIDW Fan with Direct driven motor. The unit shall be suitable for 230 ± 10% volts, 50 cycles/ second, single Phase AC supply. along The quoted price shall also include refrigerant charge, 5.0 KVA Voltage stabilizer of reputed make, Power Cabling, corded remote & Drain Pump, The unit shall be equipped with interface control module for controlling the unit. Chennai Ambient Condition with 5Star Rating units .
Supply, installion, testing and commissioning of Inverter type DX coil Hi Wall Split Type Air-conditioning Unit (indoor). Indoor unit shall be complete with evaporator cooling coil, Pre-filter, DIDW Fan with Direct driven motor. The unit shall be suitable for 230 ± 10% volts, 50 cycles/ second, single Phase AC supply. along The quoted price shall also include refrigerant charge, 5.0 KVA Voltage stabilizer of reputed make, Power Cabling, corded remote & Drain Pump, The unit shall be equipped with interface control module for controlling the unit. Chennai Ambient Condition with 5Star Rating units .
Supply, Installation, Testing and Commissioning of Timer and temperature based auto sequential control panel to sequence the operation of various indoor units. The sequential panel for unit with minimum 2.4 inch digital disply controller . The Controller should automatically start & stop the airconditioning unit as per the required schedule.In case of failure of any unit and the standby unit should take over the load with alarm. In case the operating unit is unable to maintain / achive set temparature the standby pump should also operate till the set temparature is achieved . In case of power failure as soon as the power is reinstatated , both the units should operate till the set temparature is achived and thereafter operate as per normal logic. The panel shall be suitable for third party integration like BMS compactible.
Supply, installation, testing and commissioning of condensate drain pump should be manufactured from rigid PVC suitable to hi wall unit. The quote price shall include 25mm dia. PVC pipe insulated with 9mm thick closed cell nitrile rubber (Class-O) interconnecting piping from unit to the nearest drain line, the vendor should include the necessary mounting arrangement for the pumps. ASPEN Pump
Axial fan Impeller dia to be as per manufacturing standards.
Fans Shouild be AMCA Certified for both air flow & noise.
Spring isolator to be provided for fan.
Scope of Supply: Axial Fans with Bird Screen (1 No.) with all necessary supporting arranagement.
Along with pressurization Fans , its starter panel with inclusive of cable from Panel to exhaust unit, with all other accesories required.
Note: Only incoming feeder to be provided by Electrical contractor. Starter panel are in HVAC contractor scope.
(Make : Kruger / Maico / Greenheck)
7000 CFM with 25 mm External static Pressure - Pressurization fan
Supply, installation, testing and commissioning of 18" propeller type direct drive fan, heavy duty wall mounted type complete with gravity louvers, motors, mounting brackets,, 5A plug top and required cables from nearby power socket, 600x600x20mm thick marine plywood with hole to suit impeller dia, mounting supports and other standard accessories as per specifications and suitable for operation 230 +/- 10%V, 50Hz, 1 Phase AC supply. (Make : Kruger / Maico / Greenheck)
Supply, installation, testing and commissioning of Ventilation fan circular/ cabinet type units. The unit shall be 0.6mm GIS construction, direct / belt driven centrifugal fan, High efficiency motor with IP21 protection, spring vibration isolator for fan and motor, Fire retardant canvass connections, with acoustic enclosure for fan & noise level not exceed 65 dBA at 1.5m distance, internal power and control wiring, GI base frame complete as per specifications as required. Fan motor shall be suitable for 230V, 1 phase, 50Hz AC supply. Rate shall be inclusive of Suitable power cable from isolator to equipments (7.5 RMT approximately). (Make : Kruger / Maico / Greenheck)
Air Qty: 400 CFM, ESP: 10mmWC for Toilet ventilation
Air Qty: 1000 CFM, ESP: 10mmWC Toilet Ventilation
Air Qty: 1500 CFM, ESP: 10mmWC for Fire pump room Ventilation
Air Qty: 1000 CFM, ESP: 10mmWC for STP Ventilation
Air Qty: 2500 CFM, ESP: 10mmWC for WTP Ventilation
Air Qty: 2500 CFM, ESP: 10mmWC for Electrical substation Ventilation
Supply, installation, testing and balancing of Air Distribution System consists of factory fabricated sheet metal ducting complete with supports (anchor fasteners and tie-rods, cradles, angle iron supports, GI bolts and nuts, 4mm thick self-adhesive neoprene rubber gasket, stiffeners, zinc chromate painted angle iron flanges, chipping and plastering of openings made for duct supports etc., complete as per specification. The rates quoted shall include turning vanes, straightening vanes, splitters, inspection doors probe, inlets with test openings enclosures complete with locking caps, chain, gaskets, etc.
1.2 mm thick GSS ducting (18G) – factory fabricated
1.0 mm thick GSS ducting (20G) – factory fabricated
0.8mm thick GSS ducting (22G) – factory fabricated
0.63mm thick GSS ducting (24G) – factory fabricated
Supply, Installation, Testing & Commissioning of air distribution system consists of factory fabricated GI sheet Flat Oval (elliptical) duct with pre insulated 13 mm thickness nitrile rubber FM approval factory made fittings like bends, tees, wire hanging support with crimp arrangement supports, spacing and fixing as per SMACNA standards. The rate shall be inclusive of powder coating (Mat finish) for the ducts as per the approved colour shade by Client / Architect.
1.0 mm thick GSS ducting (20G) – factory fabricated
1.0 mm thick GSS ducting (20G) – factory fabricated
0.8mm thick GSS ducting (22G) – factory fabricated
Supply and installing of Acoustic insulation, Material shall be FM approved Nitrile Rubber foam. The material should be fibre free. The density of the same shall be within 140-180 Kg/m3.The material should have a thermal conductivity Not exceeding 0.038 W/mK. The maximum surface temperature the material should withstand is 105º C and minimum temperature should be -20ºC. The Thickness of the material shall be 15mm. The material should conform to Class 1 rating for surface spread of Flame as per BS 476 Part 7.As per specification.
Supply and installation Thermal insulation on ducts with Class 'O' Closed Cell Elastomeric 9mm thick Nitrile Rubber/XLPE with density of 40 - 60 kg/cum as per the thickness mentioned below, with fire retardant adhesive and joints sealed with 3mm thick, 50mm wide nitrile rubber self adhesive tape in accordance with the approved shop drawings and technical specifications. Quoted price shall be inclusive of adhesive, tapes, etc.
Supply and fixing of Under deck insulation with make it as XLPE insulation - 25 mm thick with density of 40 - 60 kg/cum as per the thickness mentioned fixed to the soffit with the help of plastic expansion fasteners. The plastic expansion fasteners is coupled with plastic wheel to support Polyurethane slabs. The fasteners are fixed at an interval of 500 C/C
Supply and erection of pre fabricated wall acoustic Insulation for AHU Room with 50mm thick & 48kg/cm2 density glass wool with GI frame grid and covered with22 G perforated GI sheet with all accessories and supports. Etc
Supply and installation of GI volume control damper low leakage( handle type ) made out of 1.6mm thick galvanised sheet steel frame and opposed blades of 1.6mm galvanised steel with suitable links, handles, levers and quadrants for manual control of volume of air flow and for proper balancing of air distribution system.as per specification
Rectangular
Supply,installation, Testing and Commisioning of GI Motorised smoke and Fire Dampers Tested and Certified by CBRI Roorkee for 120 minutes fire rating as per UL 555/1995 Standards 16G Outer Frame 16G 3V Grooved Blades With Extended 450 mm Sleeve without Actuator. The Motorised Fire Smoke Dmaper shall have provisions for and monitoring through BMS
MOTORISED SMOKE AND FIRE DAMPER ACTUATOR CONTROL PANEL : Design, Manufacture, Supply, Installation, Testing, and Commissioning of Fire damper control panel, the control panel shall be capable of operating dampers based on fire input from FAS panel for auto operation and fire damper shall have the provision for monitoring actuator status through BMS. The multiple fire damper actuator shall be connected and controlled through single control panel. The vendor shall provide the local display with reset option. Vendor shall ensure that the control panel shall be compatible for output voltage of 220V. During fire mode fire damper will get signal from Fire panel to close the damper. Provision for fire input shall be considered in the fire damper control panel and AHU starter panel. Vendor shall consider Power cable of minimum 1.5 meter with plug top.Vendor shall consider minimum 6 actuators. Note : UPS power shall be provided to fire damper control panel.
Supply, installation, testing and commissioning of fire-retardant canvas, with GI matching flanges, with a provision of operable zip. The entire assembly shall be fabricated at factory.
Supply, installation testing & balancing of Higher grade Aluminium Extruded powder coated grilles with necessary flanges for Supply & Return air. As per specification
Supply, installation testing & balancing of Higher grade Aluminium Extruded powder coated grilles with necessary flanges for Exhaust air. As per specification
Supply, installation testing & balancing of Higher grade Aluminium Extruded powder coated Door Transfer Grille with necessary flanges for Fresh air. As per specification
Supply, installation testing & balancing of collar damper shall be constructed out of extruded aluminium alloy with multiple blade of oppose blade type. The damper to be powder coated with mat finish black colour. The damper shall be used for the Supply air diffuser & grilles as per the drawings & specifications.
Design, Manufacture, Supply, Installation, Testing, and balancing of aluminium powder coated ex.disc valve dia 150mm
Providing the third party agency for testing and balancing of HVAC system completely as per NEBB guidelines. The agency's technical credentials shall be submitted to the Client / Consultant and work can be commenced after getting approval from the Client / Consultant.
Supply, installation testing & commissioning of Higher grade Extruded Aluminium powder coated Supply Air Diffusers shall be of removable core type (without collar damper) With Outer size: 595x595mm.& 375 x 375mm neck size
Supply, installation testing & commissioning of Higher grade Extruded Aluminium powder coated Supply Air Diffusers shall be of removable core type (without collar damper) With Outer size: 595x595mm.& 450 x 450m neck size
Supply, installation testing & commissioning of Higher grade Extruded Aluminium powder coated Return Air Diffusers shall be of removable core type (without collar damper) With Outer size: 595x595mm.
Supply, installation and testing of round flexible duct inner core should be made of triple lamination of Aluminium Foil, Polyester & Metalized polyester film permanently bonded to a coated spring steel wire helix. Fiberglass insulation shall be of 25mm thick with minimum density of 16 kg/m³. The outer insulation jacket vapor barrier shall be made of fiber glass reinforced metalized polyester film laminated with aluminium foil as per the technical specifications. The rate shall be inclusive of hose clamps, supports,bolt,nut etc. AS per specification.(1.2 Mtr)
300mm Dia
250mm Dia
200mm Dia
Supply, installation testing & commissioning of Butterfly damper should constructed with Not less than 0.8mm thick galvanized steel sheet, with single flap, necessary stopper, flanges, grooves 150-mm length, neoprene gasket at the edge of blade to reduce leakage and with required hardware and accessories as per specification. Include locking device to hold single-blade dampers in a fixed position without vibration & engraved marking on position of damper, as per specifications.
300mm Dia
250mm Dia
200mm Dia
ELECTRICAL WORKS FOR VRV ODU's:
The isolator unit for single module ODU comprising 4P MCB / ELCB 300 mA in a weather proof moulded IP 55 enclosure. The unit shall be suitable for single module VRV ODU. RCBO's rating shall be suitable for the load of ODU unit. The item shall also include 4c x 6 sqmm armoured copper conductor XLPE cable and double copper earth of required length between the isolator box and the ODU unit. (Normally upto 24 HP, ODU, its single module ODU).
Single module ODU
The isolator unit for two or more ODU modules comprising 4P MCCB as incomer, tinned bus bar link work, outgoings as 4P ELCB / 300mA per module of ODU. The unit shall be complete with internal wiring and enclosed in a weather proof moulded IP 55 enclosure. The outgoings shall be one 4P RCBO / 30 0mA for each module and shall be of adequate capacity as per the load of each module of VRV ODU. The MCCB shall be sized for the load of sum of all VRV ODU modules. The item shall include 4c armoured copper conductor XLPE cable and copper wire double earth of required length from isolator box to respective VRV ODU module.
Supply and laying of 4 Core 4 sq.mm copper armoured Cable
Supply and laying of 4 Core 6 sq.mm copper armoured Cable
Supply and laying of 4 Core 10 sq.mm copper armoured Cable
MISCELLANEOUS
Supply & erection of Aluminium louvers with M.S. frame work on all AC ledges covering the entire height ( 18 Meter) from ground floor to third floor
FIRE FIGHTING
PUMPS & CONTROL PANELS
Supply, erection, testing and commissioning of Fire Fighting Application Horizontal Centrifugal Type Pump Rated for 2820 LPM at 70 metres head with Electrical Motor of 60 HP of 415 volt 3 phase connection complete with base plate and accessories. (Make: Kirloskar or Equivalent). The rate inclusive of necessary vibration, bad mounting etc., as per standard method as directed by the Deparmental Officers.
Supply, installation, testing and commissioning of Diesel Engine Driven Main Fire Pump suitable for automatic operation and consisting of following and complete in all respects as required. a. End suction, top discharge centrifugal pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg. / sq. cm at highest and farthest outlet at specified flow of 2280 LPM at 70m head conforming to IS 1520. b. 68 BHP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant BS & IS standard complete. Auto starting mechanism, 12 volts / 24 volts electric starting equipment like self motor, dyanamo, solenoid switches etc.c. 110 litres capacity diesel tank mounted over stand fabricated using 25mm x 25mm x 6mm size MS angle, providing with level indicator, inlet port, outlet port, drain port and diesel return line port and fuel pre-filter, after filter etc. (Make: Kirloskar / Equivalent).
d. Exhaust system having flexible metallic mufler, 100mm dia MS heavy pipe extended upto 1m, outside pump house duly insulated with 50mm thick glass wool with 1mm thick aluminium sheet cladding, residential silencer with necessory MS support arrangements from wall or ceiling as per site condition. e. Dash board consisting the instruments like temperature gauge, galvano type DC Ammeter, lubricant oil pressure gauge, ignition switch, emergency stop and all other protection equipment as per specification, stop seleneid for auto stop in the event of fault with audio indications, painted with post office red colour etc., as required. f. 12 V / 24 V storage battery, maintenance free tape, 180 AH rating, MS fabricated common base plate, coupling guard, foundation bolts etc., as required. g. Positioning the diesel engine driven fire pump over cement concrete foundation using suitable size anti-vibration mounting arrangement. All works carried out as per standard methods and as nstructed by the manufacturer and as directed by the Departmental Officers. (Make: Kirloskar / Equivalent)
Supply, erection, testing and commissioning Mono Block type Fire Fighting Pressurisation Pump of 180 LPM 110 metres head at 10 HP with suitable base frame including necessary vibration bad mounting etc., including conveying, fixing and incidental charges., etc., complete as per standard specification and as directed by the Departmental Officers. (Make: Kirloskar / Equivalent)
Supply, erection, testing and commissioning of fire fighting application monoblock motor pumpset of 900 LPM at 40 metres head to develop 3.5 kg/sq.cm at the heightest and farthest hydrant point to make 30 m water jet at the time of fire fighting emergency cicumstances, coupled with 11 KW / 15 HP rated three phase 414 volts, 50 Hz, 2880 rpm electrical motor the pump with cast ron body, bronze impeller, rope gland packaging, suction size of 80 mm dia. delivery size of 65 mm dia., including the cost of foundaton concrete anti vibration mounting, rain safety hood and etc. complete as directed by the Departmental Officers (Kirloskar make KDS 1555+ or Equivalent)
Supplying, erection, testing and commissioning of Diesel Engine Pump Main Control Panel & Jockey Pump including necessary auto cut-in, cut-off and manual operations, battery charger switch arrangements, voltmeter, ammeter and running indication siren provision, wall mounting type, etc., as per the standard method and as directed by the Departmental Officers.
Supply and laying of following sizes of Armoured Aluminium / Copper Cables for electrical motor, control panel, pressure switch, jockey motor etc., all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: POLYCAB / PARACON / FINOLEX / EQUIVALENT.
3.5 core 185 sq.mm. armoured aluminium cable
4core 10 sq.mm. armoured copper cable
10 core 2.5 sq.mm. armoured copper cable
2 core 2.5 sq.mm. armoured copper cable
Earthing arrangements with GI Earth Plate including charcoal and salt with necessary excavation in all soils and to full depth as may be required and masonry work, re-filling the sides of foundation with excavated earth as per the standard specification and as directed by the Departmental Officers.
VALVES & GUAGES
Supply, erection, testing and commissioning of following sizes of Heavy Duty Foot Valve including all accesories, such as, MS flange of table ‘E’, gaskets, bolts & nuts, etc., installed at end of 150 / 200mm dia suction pipe line at sump including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete and as per standard specification and as directed by the Departmental Officers. Make: NORMEX / KARTAR / EQUIVALENT
200mm Dia
Supply, erection, testing and commissioning of cast iron body and bronze internal non-rising spindle sluice valve of sizes at required places to control the flow of water including necessary MS flange of table ‘E’, gaskets, bolts & nuts including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: NORMEX / KARTAR / EQUIVALENT
200mm Dia
150mm Dia
80mm Dia
65mm Dia
Supply, erection, testing and commissioning of Cast iron body and Gun metal or stainless steel internal Non-return valve of following sizes to control one way flow of water to be installed pump room at delivery line and near overhead tank at terrace level near to jockey pump and motor including necessary MS flange of table ‘E’, gaskets, bolts & nuts, etc. as per IS 5312 including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers.
200mm Dia
Supply, erection, testing and commissioning of cast iron body and gun metal or stainless steel Internal Non-Return Valve of size of 80mm dia to control one way flow of water to be installed pump room at delivery line and near overhead tank at terrace level near to jockey pump and motor including necessary MS flange of table ‘E’, gaskets, bolts & nuts, etc. as per IS 5312 including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers.
Supply, erection, testing and commissioning of Gun Metal Gate Valve of size 50mm dia size including necessary MS flange of table ‘E’, gaskets, bolts & nuts etc., installed at pump house delivery line for the purpose of priming water to suction line including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: LEADER / EQUIVALENT
Supply, erection, testing and commissioning of Pressure Gauge with 0 to 14 kg. range of reputed make with necessary valve, milling thread MS coupling fixed at delivery pipe line in pump house to read the developing pressure including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: H-GURU / ISI MAKE / EQUIVALENT.
Supply, erection, testing and commissioning of suitable Pressure Switch of reputed make line Indfoss or Donfoss including necessary valves, couplings, etc., connected with electrical main control panel and setup at proper differential so as to auto start and auto stop the electrical motor, jockey motor including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., completed as per standard specification and as directed by the Departmental Officers. Make: DONFOSS / INDFOSS / ISI MAKE / EQUIVALENT.
Supply, erection, testing and commissioning of Air Release Valve of 20mm dia, so as to release airlock in 100mm dia MS pipe at top most wet riser, including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: KARTAR / EQUIVALENT.
Supply, erection, testing and commissioning of Fire Fighting 4 Way Fire Brigade Inlet with necessary gun metal 63mm dia non return spring shutter arrangements, so that to control one way flow at the time of emergency water supply by fire and rescue service fire engine entry including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: KIARTAR / OMEX / EQUIVALENT.
Supply and fixing of Fire fighting application oblique type stainless steel Hydrant Valve of size 63mm dia with oblique type instantaneous coupling with rotating wheel to open and close the valve including MS flange of table “E”, bolts & nuts with washer as per IS 5290 at ring main around the building and wet riser inside the building including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT.
Supply, installation of Fire Fighting Application 180 degree swinging type, hose reel drum with 20mm dia braided thermoplastic hose of 30 metres long, so as to extend to necessary distance by self rolling spindle wheel including necessary 20mm dia ball valve and open and close spray nozzle, warm clip, etc., as per the standard pattern of any
reputed make at every floor nearer to hydrant valve, including
conveyance, all incidental charges, neccessary scaffolding
and re-doing the dismantled portions to its original condition
wherever found neccessary., etc., complete as per standard
specification and as directed by the Departmental Officers.
Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD /
EQUIVALENT.
Supply, and fixing in position of Fire Fighting Application Hose of 63mm dia of 15 metres length binded by copper wire with 63mm dia stainless steel male and female instantaneous fire fighting special coupling as per IS 901 as directed by the Departmental Officers. Near every hydrant points including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR/ LIFE GUARD / SAFE GUARD / EQUIVALENT.
Supply, and fixing in position of Fire Fighting Application 63mm dia stainless steel short length Branch Pipe with hexagonal type spray nozzle of 15mm (or) 20mm jet bore. Near every hydrant points including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT.
Supply of Fire Fighting Application MS Hose Box to keep two number of hoses and 1 No. of branch pipe with nozzle having proper glass window type double door with universe open key, painted inside white and outside Post Office Red. Near every hydrant point including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT.
Supply and fixing nominal bore quartized bulb type sprinkler bulb 68 Deg C fast response pendent type including GI collar for each sprinkler bulb, mounted in MS pipe line using suitable size MS threaded coupling, thread, shellac etc., as per standard methods and including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT.
Supply, Installing, testing and commissioning of Stainless Steel Corrugated Flexible Braided Pipe (Hose) for dropping sprinklers below false ceiling. Pipe shall be 16 bar pressure rating and 1500mm long, 25mm dia with union / reducer, collar, clamps, etc. It shall have UL listed and FM approved.
Supplying and installing of approved type Rosette Plates (Recessed Type in Two Pieces) for sprinklers below false ceiling area. The Rosette shall be fabricated by MS plate of 2mm thick and the finish shall be powder coated and colour, as directed by the Departmental Officers.
Supply and kept in position of 9 litres capacity Fire Buckets of 4 Nos. with Bucket Stand as per standard specifications and as directed by the Departmental Officers
FIRE EXTINGUISHER
Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT
Supply and fixing of Carbon-di-Oxide Gas Type 2 kg. capacity Fire Extinguisher as per New IS15683, complete with control valve, discharge hose with horn, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc., complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT
MS PIPES & SUPPORTS
Supply, erection, testing and commissioning of following MS ‘C’ Class Heavy Duty Pipe as per IS 1239 to withstand a developing pressure of 10 kg. / sq.cm including necessary fittings like MS flange of table ‘E’, elbows, reducers, gaskets, bolt, nuts with washers & joints as per standard method of arc welding, including one coat metal primer and two coat Post Office Red painting including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: JINDAL / EQUIVALENT
200mm Dia
150mm Dia
100mm Dia
80mm Dia
65mm Dia
50mm Dia
40mm Dia
25mm Dia
Wrapping and coating anti-corrosive treatment for the following under ground MS pipe having one coat of anticorrosive metal primer, one layer of asphalt tar tape wound over the MS Pipe as per standard methods as per standard specifications and as directed by the Departmental Officers.
200mm Dia
150mm Dia
Providing, fixing pipe supports from columns / wall or suspenders from roof slab to suit various dia of pipes made out of GI / MS adjustable rods threaded for a sufficient length to adjust the height of support along with clamping arrangement for holding pipes of anchor fastening, arrangement design of hanger and should confirm with specification.
150mm Dia
100mm Dia
80mm Dia
65mm Dia
50mm Dia
40mm Dia
32mm Dia
40mm Dia
SIGNAGES (FOR EMERGENCY)
Providing and installing in position the following type of sign boards made out of 3mm thick "Opaque" PVC foam board with computer cut, PVC non-reflective self adhesive vinyle painted foam board, complete with mirror fasteners. Make : Prolite / Ravel
Signage with printed "IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE" of 1.5cm height letters in red with white back ground.The size of the board shall be 25cm x 30 cm and shall be fixed at the height of 2 mts. from finished floor near Manual call points. Make : Prolite / Ravel
Floor indentification signage ( ie, GROUND FLOOR …etc.) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 7.5 cm with contrasting colour from back ground.Size shall be 15cm x 60cm.Make : Prolite / Ravel
Providing and fixing in position the signages " FIRE ORDER" it should contain the following matter on 3mm thick "Opaque" PVC foam board of computerised cut, PVC non-reflective self adhesive vinyle painted foam board of 3' x 4'. ALERT THE SECURITY AT SECURITY ROOM BY ACTUATING MANUAL CALL POINT LOCATED AT STRATEGIC LOCATION . EVACUATE THE OCCUPANTS BY USING THE FIRE EXITS & EMERGENCY EXITS ONLY. ASSEMBLE AT VARIOUS ASSEMBLY POINTS. IF POSSIBLE TRY TO EXTINGUISH THE FIRE BY USING THE NEAREST/SUITABLE PORTABLE EXTINGUISHER OR WATER FROM NEAREST WET RISER BE CALM, DO NOT GIVE ANY ROOM FOR PANIC, WALK, DO NOT RUN IF YOU ENCOUNTER SERIOUS DIFFICULTY IN EVACUATION, STAY IN YOUR PLAN AND TRY TO ATTRACT ATTENTION OF RESCUE TEAM . Make : Prolite / Ravel
Providing and installing in position the following type of sign boards made out of 3mm thick "Opaque" PVC foam board with computer cut, PVC non-reflective self adhesive vinyle painted foam board, complete with mirror fasteners ACTION BY SECURITY/RECEPTION UPON RECEIPT OF INFORMATION THROUGH FIRE ALARM OR FIRE DETECTORS OR BY USING PUBLIC ADDRESS SYSTEM. A) ALERT THE OCCUPANTS BY USING PUBLIC ADDRESS SYSTEM. B) INFORM FIRE CONTROL THROUGH ANY ONE OF THE FOLLOWING PHONE NUMBERS: C) IN CASE OF THE CASUALTIES, CALL AMBULANCE BY DIALLING NUMBER…….. FIRE FIGHTING AGNECY ------------------------------- PHONE : ----------------------- FAX : ----------------------------
Fire and emergency signage Boards( Fire escape directions, First aid charts, First aid box indications, safe material handling procedures, Fire assembly area indications etc,)
Providing and installing of Fire Evacuation Plan with route in rectangular Acrylic sheet with ss bolt of size 600 x 450mm & 2 to 3mm thick
PLUMBING
PART - A SANITARY FITTINGS
Supplying and fixing of wall mounted white colour European water closet Parryware or equivalent, with seat cover and dual flush (3/6 lit) cistern having P trap with seat cover, supplying non corrosive hinges, CP bolts, nuts, washers, providing and fixing dash anchor fastners with bolts / L - brackets with anticorrosive paint cutting grooves in masonry or concrete surfaces, grouting with cement concrete 1:2:4 mix, using 20mm size stone jelly, restoring the damaged portion to their original condition using required materials, fixing the water closet to perfect level, alignment, testing etc. complete.
Supply & Fixing of CP Health Faucet of the wall mounting type with hook & hose connected to Angle valve complete fittings.
Supplying and fixing of floor mounted white colour European water closet Parryware or equivalent, with seat cover and dual flush (3/6 lit) cistern having P trap with seat cover, supplying non corrosive hinges, CP bolts, nuts, washers, providing and fixing dash anchor fastners with bolts / L - brackets with anticorrosive paint cutting grooves in masonry or concrete surfaces, grouting with cement concrete 1:2:4 mix, using 20mm size stone jelly, restoring the damaged portion to their original condition using required materials, fixing the water closet to perfect level, alignment, testing etc. complete.
Providing and keeping in stores, shifting to the place of installation, fixing, testing and commissioning of WHITE coloured vitreous china Table top Regular/Circular wash basin with brackets / G.I. rag bolts and nuts painted, 32mm dia brass C.P. waste coupling, (heavy), 15mm dia brass C.P. cold water connecting pipe, etc., The work shall include,required extension nipples, cutting / chasing and making good the walls and floors - toilets. Size 550mm x400mm
Supplying & fixing of Long body Bibcock with brackets including fixing over Wall tile dado complete.
Supplying & fixing of Angle valve stopcock with connecting hose and wall flange.
Tissue holder :Supplying and fixing approved best quality brass CP paper holder and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc.,complete complying with standard specifications. .
Providing & fixing Mirror panelling fixed on base panelling with 12mm thk ply with 6mm thk Mirror with 1" bevelling,Complete with 25mm" Dia SS finish stud & sides finish in T.W Beading patti finished in polish/paint.
Supplying and fixing best approved best quality CP stop cock 15mm dia including cost of brass screws, etc., complete complying with standard specifications.
Supply and fixing of urinal sensor similar to parryware make :C829599 including accessories as required.
Flat Back Urinal :Providing and keeping in stores, shifting to the place of installation, fixing, testing and commissioning of white viterous china white color large flat back urinal with spreader flushing supported by CI/MS bracket including built in waste grating with extension piece, wall flanges,flush piping, Size 400mmx400mmx600mm
Supply and fixing of approved make HDL urinal partition dividers
Supplying & fixing of Coat hook with brackets including fixing over Wall tile dado / door shutter using suitable size non-corrosive screw nails etc.
Providing and keeping in stores, shifting to the place of installation, fixing of stainless steel sink with brackets / G.I. rag bolts and nuts painted, 32mm dia brass C.P. waste coupling, (heavy) 32mm dia brass C.P. bottle trap, 15mm dia brass C.P. Piller cock with flange, 15mm dia brass C.P. cold water connecting pipe, etc., The work shall include,required extension nipples, cutting / chasing and making good the walls and floors - toilets. 600mmx600mmx200mm size
Supply & fixing of 300ml Soap dispenser made up of plastic material, wall mountable type.
Supply and fixing of solid state, no touch operting, fully hygienic ABS body hand drier of approved shade with single blower, with time delay, summer & winter control, music while drying, volume ON/OFF controls. (Location - For All toilets) (Make: Urban Desire/Equivalent)
Supply & fixing of ss304 stainless steel 32mm dia 450mm length straight grab bar in PHC toilet.
Supply & fixing of SS304 stainless steel 32mm dia swing grab bar in PHC toilet
Supply & Fixing of ABS body open type Tissue dispenser.
PART - B SOIL, WASTE AND VENT PIPE LINES
Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with PVC specials, PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages,etc., complete complying with standard specifications.
40mm dia. 6kg class PVC pipes.
50mm dia. 6kg class PVC pipes.
75mm dia. 6kg class pipes.
110mm dia. 6kg class pipes.
Supplying and fixing in position PVC nahini /Floor Trap with SS Grating type of size 100x75/75x50 mm with best quality gratings of approved brand fixed over a bed of brick jelly lime concrete 1:2:5(One lime two sand and five aggregate) brick jelly 40mm and finishing with CM 1:3(One cement and three sand)wherever found necessary and making good to the original condition and giving connections to the PVC pipes etc.,
Supplying and fixing in position PVC Floor Clean out with SS Grating type of size 100x75/75x50 mm with best quality gratings of approved brand fixed over a bed of brick jelly lime concrete 1:2:5(One lime two sand and five aggregate) brick jelly 40mm and finishing with CM 1:3(One cement and three sand)wherever found necessary and making good to the original condition and giving connections to the PVC pipes etc.,
Supply and fixing in position best quality PVC IS 4985 - CLASS-II - 4 Kg/Sqcm -Rain water pipes of various size having ISI mark and providing leak proof joints with such as Bend, Tee Junction, door etc.,of approved qualityincluding fixing to the wall with special PVC /MS clamps, etc., and making connection to all sanitary fittings, wherever necessary and making chipping good to the original condition, complying with standard specification etc., complete.
160mm dia. 4kg class pipes.
Supplying and fixing in position of the following dia PVC roof drain dome with 160mm out let for rain water pipes ,of approved quality and variety of various size confirming to ISS and including necessary cutting and fixing and giving connection to PVC pipes etc.,
Supplying and fixing in position of the following dia PVC specials such as PVC vent Cowl etc.,of approved quality and variety of various size confirming to ISS amend providing leak proof joint etc., including necessary cutting and fixing and giving connection to PVC pipes etc.,
50mm Dia
75mm dia
110mm dia
PART-C - EXTERNAL DRAINAGE
Supply and fixing in position best quality PVC IS 4985 - CLASS- III - 6 Kg/Sqcm -Soil/ waste pipes of various size with approved quality and variety of various size confirming having ISI mark and providing leak proof joints including erection of below ground with excavation and refilling etc., and making connection to Manholes / Gully trap, wherever necessary and making chipping good portion to the original condition, complying with standard specification etc.,complete.
75mm dia. 6kg class III-pipes.
110mm dia. 6kg class III-pipes.
160mm dia. 6kg class III-pipes.
Supply and fixing in position best quality PVC IS 4985 - CLASS- III - 4 Kg/Sqcm -Soil/ waste pipes of various size with approved quality and variety of various size confirming having ISI mark and providing leak proof joints including erection of below ground with excavation and refilling etc., and making connection to Manholes / Gully trap, wherever necessary and making chipping good portion to the original condition, complying with standard specification etc.,complete.
160mm dia. 4kg class III-pipes.
Supply, laying and erction of glazed stone ware gully trap (100 x 75 mm) with 100 mm dia, outlet including embedding trap in cement concrete 1:3:6 and constructing chamber of size 300 x 300 mm inside clear in brick masonry 230 mm thick, plaster with water proof cement mortar (1:3) 15 mm thick on both internal and external surfaces inside finished with floating coat of neat cement. The work including excavation to required depth of gully trap and refilling and making good in the surface with Providing and fixing SFRC frame and cover 400 x 400 mm (clear opening) complete complying with std. specification.
Supplying and Erection and construction of sewer chambers of required internal dimensions 450x450 upto 0.6 mtr.depth with 230mm brick masonry in C.M.1:5 thk of masonry over bed of 1:2:4 R.C.C. 200 mm thk bove 100 mm thk P.C.C.1;3:6 Cement concrete foundations over sand bed of 100mm thk channelling in 1;2:4 cement concrete, plastering in 1:3 cement mortar for internal and external surface finished with floating coat of neat cement, the work including excavation for required depth of gully trap and refilling and making good in the surface with SFRC cover and frame 450x450mm (clear opening)complete complying with standard specifications etc.,
Construction of rain water recharge well of 1200mm dia and depth upto 1500mm, in addition 110 dia special blue slotted pipe for bore well.pipe should be laid from bottom of ring well centre to below 1500mm as shown in the drawings, including all types of excavation,occur for pipe, filling of rain water harvesting materials with construction of R.C.C. ring and top 100mm RCC SLAB WITH 450X450mm perforated SFRC manhole and 230mm brick wall in 2'height with below 300mm lengthx100mm thk P.C.C. as per the structural filling the filter media as per drawing.
D. WATER SUPPLY SYSTEM
Internal Concealed Works
Providing, supplying & laying of Chlorinated Poly Vinyl Chloride (CPVC-SDR-13.5) Pipes conforming to IS 15778 having thermal stability cold water with brass and CPVC fittings like Elbow, Brass Tee, Brass Elbow, Offsets, Tee with clamps @1.00 meters spacing, with jointing of pipes with one step CPVC solvent cement with including cutting of chase including testing of the joints complete and making good the walls etc. Rate is inclusive of all material labour, transportation, tools & tackles taxes, etc all complete as per as per specifications, Exposed work including chase cutting, bracket fixing)
20 mm nominal (OD) pipes
32 mm nominal (OD) pipes
E.EXPOSED PLUMBING WORKS
Providing, supplying & laying of Chlorinated Poly Vinyl Chloride (CPVC-SDR-13.5) Pipes conforming to IS 15778 having thermal stability cold water with brass and CPVC fittings like Elbow, Brass Tee, Brass Elbow, Offsets, Tee with clamps @1.00 meters spacing, with jointing of pipes with one step CPVC solvent cement with including cutting of chase including testing of the joints complete and making good the walls etc. Rate is inclusive of all material labour, transportation, tools & tackles taxes, etc all complete as per as per specifications, Exposed work including chase cutting, bracket fixing)
25mm nominal(OD) pipes
32mm nominal(OD) pipes
40mm nominal(OD) pipes
50mm nominal(OD) pipes
65mm nominal(OD) pipes
F. EXTERNAL PLUMBING WORKS
Providing, supplying & laying of Chlorinated Poly Vinyl Chloride (CPVC) Pipes conforming to IS 15778 having thermal stability cold Metro water with brass and CPVC fittings like Elbow, Brass Tee, Brass Elbow, Offsets, with jointing of pipes with one step CPVC solvent cement with including Earth excavation & refilling complete.Rate is inclusive of all material labour,transportation, tools & tackles taxes, etc all complete as per as per specifications,Concealed work including chase cutting) Pipe laid below ground level
32mm UPVC pipes
40mm UPVC pipes
50mm UPVC pipes
Providing, supplying & laying of Gunmetal type ball valve pressure rating not less than 16 Kg/Sqcm and IS778 with 2 Nos of MTA with jointing material like shellac, thread including testing of the joints complete and making good the walls etc. Rate is inclusive of all material labour, transportation, tools & tackles all complete as per as per specifications,
Supply and laying of 300mm Dia HDPE pipe for road crossing. Rate shall include earth excavation and refilling of soil as required at site.
Supplying, fixing, jointing, testing and commissioning of bronze Ball Float Valve with stainless steel stem, nuts & springs, rubber diaphragm & disc, cable with all necessary fittings & accessaries.
a) 50 mm dia
Supplying, installing, fixing, jointing, testing and commissioning of Puddle flange consisting of 6mm thick welded GI / MS plate, flanges of sutible size hot dip galvanised to 100 micron properly fixed in walls of water tanks as per specifications and approved drawings and shall be of following diameters.
a) 40 mm dia
b) 50 mm dia
c) 75 mm dia
d) 100 mm dia
e) 150mm dia
Supplying, installing, fixing, jointing, testing and commissioning of Brass Automatic Air release valves including ball valve, unions etc., Complete
a) 20 mm dia (Screwed ends)
WATER PUMPS
DOMESTIC WATER BOOSTER PUMP
Supply , fixing and commissioning of Hydropneumatic pumps (1 working and 1 standby) Vertical in line type for pumping the water from underground sump to distribution header running buried underground level through hydropneumatic pressure vessel for domestic purposes. The pump shall be coupled to adequate H.P. electrical motor, mounted on a common base frame made out of 'GI' with necessary bolts and nuts.IE5
The pump shall be suitable for the following requirements:
Flow rate of each pump - 6.0 Cu.m/hr
Pump design head -45 m
Pump to be fitted with one VFD
The pumps shall be provided with:
Rate shall include Pessure switch, pressure gauge, valves, NRV, Manifold, Automatic booster card and micro processor based control panel, etc. Complete.
PUMPROOM DEWATERING PUMP
Supply , fixing and commissioning of Transfer pumps (1 working ) Submersible type for pumping the water from pumproom to storm water trench. The pump shall be coupled to adequate H.P. electrical motor, mounted on a common base frame made out of 'GI' with necessary bolts and nuts.
Paint shall be suitable for coastal environment
The pump shall be suitable for the following requirements:
Flow rate of each pump - 6.0 Cu.m/hr
Pump design head - 20 m
Rate shall include Pessure switch, pressure gauge, valves, NRV, Manifold, Automatic booster card and micro processor based control panel, etc. Complete.
Supply, installation and commissioning of 2500 LPH WTP plants with equipment's/electrical panel /piping for WTP plant as description given in below:
a. Filter Feed Pumps - Horizontal, centrifugal Pumps Self priming type complete with motor, base plate, coupling etc with wetted parts, in CI - 2 Nos. (1W+1S) complete with panel and accessories and shall have dry run protection and weather proof enclosure :
b. Hypo Dosing system of electromechanical type pf capacity 0-3 Lph, dosing pump, storage tank of
c. Pressure Sand Filter with a filtration with Filter media, Multiport valve and with necessary accessories
d. Activated Carbon Filter with a filtration with Filter media, Multiport valve and with necessary accessories
e.Softner with a filtration with Filter media, Multiport valve and with necessary accessories
SEWAGE TREATMENT PLANT
Design, Engineering, and providing all equipment / machinary at site, installation and commisioning of equipments/ electricals/ piping for 25KLD MBBR type STP plant.
Parameters : Quality of Raw Sewage in Mg/l COD ≤ 600 SS ≤ 300 BOD ≤ 400 pH - 6 to 8, Treated Water standard achieved by the STP process in Mg/l COD ≤ 150 SS ≤ 20 BOD ≤ 20 pH - 6.5 to 8, Raw Sewage Source - STP Supplying, installing, testing and commissioning of Bar screen - 1 no. Type: Manual type MOC: SS 304, Raw Sewage Transfer Pumps - 2nos. ( 1 working + 1 stand by) Type: Submersible pump MOC: CI Make: Kirloskar/CG/EQ Power: 2.0 HP Raw Sewage Transfer Pumps - 2nos. ( 1 working + 1 stand by) Type: Submersible pump MOC: CI Make:
Kirloskar/CG/EQ Power: 2.0 HP Aeration tank - 1 no. Volume: 6000 Liters MOC: FRP. Settling cum Intermediate Tank - 1 no. Volume: 3400 Liters MOC: FRP Settling cum Intermediate Tank - 1no. Volume: 3400 Liters MOC: FRP Sludge Recirculation Pumps - 1 no. Type: Self Priming pump Power: 0.5 HP Make: Kirloskar/EQ Air Blower with motor - 2nos. ( 1 working + 1 stand by) Air flow: 30 m3/hr Make: Airvak/EQ Diffuser - Coarse 1 Lot Type: Disc Air flow: 6 m3/hr (80mm dia) MOC: EPDM Diffuser – Fine for Aeration tank – 1 Lot Type: Fine Bubbl, Air flow: 6 m3/hr (63mmx610mm), MOC: EPDM, Make: Proflex/EQ
Chlorine Dosing Pumps - 2nos. ( 1 working + 1 stand by) Capacity : 0-4 LPH @4 Kg/cm2, MOC: PP, Make: Edose/EQ
Dosing Tank - 1 no. Capacity:50Ltrs,MOC:LDPE
Filter Feed Pumps - 2nos. ( 1 working + 1 standby)
Providing and fixing 5000Ltrs FRP Anaerobic Septic tank with Each,inlet, outlet, vent and necessary FRP Straps, Eye bolt,wire rope, turn buckle for anchoring and factory madeconcrete blocks to counter buoyancy etc all complete.. Rate shall also include earth exacation and refilling as required for completion of work.For security guard room
EXCAVATION
Earth work excavating and depositing on bank with initial lead of 10 m & initial lift of 2m in Hard stiff clay, stiff black cotton, hard red earth, shales, murram, gravel, stoney earth and earth mixed with small size boulders.
All Kind of Soil - (Upto 2.00m depth from NGL)
All Kind of Soil - (Upto 2.00m to 3m depth)
Supplying and filling in foundation and basement with filling Conveyed earth in layers of not more than 15 cm thick well rammed watered and consolidated complying with std spec.
Cement Concrete 1:4:8 (One Cement, Four Crushed stone sand and eight hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete (The crushed stone sand to be used on concrete work shall confirm to gradation as per IS 383-1970)
FORM WORK
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)
Raft Slab
Shear Walls
Cover & Roof slab
Pump room - roof beam
Pump room - Column
CONCRETE
Providing of placing RMC Reinforced Cement concrete of the following grades using Slag Cement, machine crushed coarse agrregates 20 mm and 12.5 mm, M sand, Water and admixture etc complete all for casting concrete elements of all shape and size and at all heights. (M35 Grade - 425 Kg/Cum)
M35 Grade Concrete
Substructure
Raft Foundation
Cover & Roof Slab
Shear Walls
Foundations below the Plinth level
M30 Grade Concrete
Pump room - roof beam
Pump room - Column
STEEL REINFORCEMENT
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification, Grade of Steel ( Fy )- Fe - 550 Confirm to IS : 1786: 1985.
MASONARY WORK
Masonry work FlyAsh Bricks of size 230 x 110 x 70 mm in cement mortar 1:6 (one of cement six of sand) for super structure in all floors including fixing frames of door and windows, proper setting curing etc., complete complying with standard specification as directed by the departmental officers.
For Superstructure in Ground Floor
For Superstructure in Terrace Floor
JOINERY
Providing and fixing of 25 mm thick Flush shutter, with 6 mm ply finished with 1 mm thk laminate on both sides of the shutter and finishing with 3 horizontal grooves of 6 mm x 6 mm and beech wood door frames of size 90mm x 50mm. using hinges, locks and door closure. Cost is inclusive of providing beech wood door frame duco painted / polished to desired color.
UPVC Ventilator : Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
MS WORK
Supplying and fixing mild steel grills for windows, ventilators, etc., including priming coat etc., complete.
PLASTERING
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three M.Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the Engineer-in charge.
In Basement Floor
In Ground Floor
Plastering with Cement Mortar 1:5 (One cement and M.sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the Engineer-incharge.
Prepare surfaces and plaster with CM 1:5 (1 cement: 5 fine sand) 17mm thick(12mm+5mm) to all exterior faces of walls including hacking as required on RCC surfaces continuous to masonry in super structure and 12mm will be rough plastering includes water proofing chemical compound and 5mm will be sand paper finishing & double layer chicken mesh .The rates including curing, providing and removal of scaffolding, cost of materials, labour, equipments and machinery, all leads and lifts, loading and unloading, transportation and all other incidential charges etc, all as complete and directed by Engineer in charge at all levels.
In Ground floor
In Terrace floor
Plastering with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 12mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including mortar plasticizer at 200ml per 50Kg of cement used, finsihing, curing, etc., complete in all floors complying with standard specification and as directed by the departmental officers.
PAINTING
White washing three coats with best shell lime in all floors complete complying with standard specification and as directed , including gum, conjee, water, etc., complete.
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
Painting two coats of newly plastered wall surface with Weather Proof Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
FLOORING
Providing Granolithic floor finish 40mm thick with Plain Cement Concrete 1:2:4 using 3 to 10mm ISS HBG metal, river sand and including rubbing the top surface smoothly thread lining if found necessary and curing etc. complete complying with standard specification and as directed by SIPCOT Officers including cost and conveyance of all material and labour, incidental charges, etc. complete.
Supplying & laying of sun reflective index tiles 305 x 305 x 7 mm of 30 mm thick in cement mortar 1:3, 30 mm thick using white cement and hard crate mixed same colour pigments etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) - IN TERRACE AREA
WATER PROOFING
TERRACE
Surface Treatment: Providing and laying water proofing treatment of podium including cleaning the surface with wire brush, treating all surface cracks, construction joints and honeycombs by grouting with specialised non shrink grout and preparation of surface in all aspects to receive the waterproofing.
Bore Packing / Core Cut Treatment: Providing and sealing the gaps in the core cuts around PVC pipes treated with ReArm Bond SBR 45 bonding agent & sprinkled sand; using a non shrink grout ArmGrout M 50 or equivalent of followed by sealing of the same joint by using Joint Tape SealArm Joint Tape 2000 or equivalent with Epoxy adhesive.
Coving: Providing and Applying at the junction of slab and vertical offsets with Cement Mortar 1:4 and admixed with ReArm Bond SBR 45 at dosage of 1Ltr per 50kg cement.
Application of Primer: Apply Water based Epoxy based primer FloArm Primer EPW 44 of MYK Arment or equivalent over well prepared surface at 200-400 gm per Sq.Mtr.
Application of Polyurethane waterproof coating: Providing and applying Two coats of liquid applied single component polyurethane based waterproofing system AquaArm WPU-1KE of MYK Arment or equivalent . It has to be applied 2.6 @kg/sqmtr to achieve a thickness of 1.2 mm in two coats.The membrane will have the following technical parameters: Tensile Strength : 1.4 N/mm2 ,. Elongation at break : 450% , Adhesion To concrete: >1.5 N/mm2,
Providing and laying 150 Gsm Geo fabric membrane as separation layer
Protection Screed: Horizontal Areas: Providing and Laying M25 grade screed concrete in 1:100 to a average thickness of 100 mm mixed with Integral Waterproofing admixture AquaArm Proof WP 10 at the dosage of 125 ml/bag of cement over waterproofing layer to a minimum thickness of 75 mm as per site requirement(Civil Contractor Scope) including control joints of 4M X 4M size and filling the panels with polyurethane sealant.
STP- WATER PROOFING
Surface Preparation: Providing and laying water proofing treatment to horizontal and vertical surfaces of podium slabs, including cleaning the surface with wire brush, treating all surface cracks, construction joints and honeycombs by grouting with specialised non shrink grout,coving preparation at wall - slab joint and preparation of surface in all aspects to receive the waterproofing.
Bore Packing / Core Cut Treatment: Providing and sealing the gaps in the core cuts around PVC pipes treatedwith SBR bonding agent & sprinkled sand; using a non shrink grout ArmGrout M 50 or equivalent of followed by sealing of the same joint by using Joint Tape SealArm Joint Tape 2000 or equivalent with Epoxy adhesive.
Coving: Providing and Applying at the junction of slab and vertical offsets with Cement Mortar 1:4 and admixed with SBR at dosage of 5 litre per 50kg cement. (cement and sand shall be supplied by the main contractor)
Waterproofing Coating-Providing and applying two compoent acrylic cementitious coating AquaArm TG of MYK Arment or equivalent with a coverage of 2.0 kg /m2 .The coating shall be taken upto 300mm from finished floor level on the vertical walls.The coating shall have an elonagtion of 40%,Shore A hardness of 90,Tensile strength of 0.86 N/mm2.
Protection Screed: Horizontal Areas: Providing and Laying M25 grade screed concrete in 1:100 to a average thickness of 100 mm mixed with Integral Waterproofing admixture AquaArm Proof WP 10 at the dosage of 125 ml/bag of cement over waterproofing layer to a minimum thickness of 75 mm as per site requirement(Civil Contractor Scope) including control joints of 4M X 4M size and filling the panels with polyurethane sealant.
Water Stops for Joints : Supply and apply of WPM SW a swellable waterbar based on polymer technology and designed for use in construction joints.
MISCELLANEOUS
Providing and fixing PVC coated MS rungs as per drawing and instruction of Engineer in-charge complete.
Providing and fixing in position Heavy duty precast SFRC. manhole cover and frame.Square shape 600mm internal dimensions
INSTRUMENTATION AND CONTROL WORKS ( ELEV,IBMS FAS PAS )
Supply, installtion, testing and commissionign of IP based 4MP IP Dome Camera with 2688 × 1520 resolution , 1/3" Progressive Scan CMOS , Color: 0.003 Lux @ (F1.4, AGC ON), B/W: 0 Lux with IR , 4 mm Fixed Lens , Support 40 Meter IR Range , Support Four Stream , H.265+ Video Compression , 120 db WDR , BLC, HLC, 3D DNR, Defog , 1 RJ45 10 M/100 M self-adaptive Ethernet port , support microSD/microSDHC/microSDXC card, up to 512 GB. operating temperature -10 to +55 deg C, Day Night cameras, Tamper & Motion Detection feature, Vandal Proof & Motion detection, POE, ONVIF compliant complete with IP 54 Housing, Connectors, Lens, Camera Mounts, Power Supply, I/O and all Ancillary Equipment & all accessories
Supply, installation, testing and commissioning of Outdoor 4 MP Varifocal Lens Bullet Camera 2688 × 1520 resolution , 1/3" Progressive Scan CMOS , Color: 0.003 Lux @ (F1.4, AGC ON), B/W: 0 Lux with IR , 2.7-13.5 mm Varifocal Lens , Support 60 Meter IR Range , Support Four Stream , H.265+ Video Compression , 120 db WDR , BLC, HLC, 3D DNR, Defog , 1 RJ45 10 M/100 M self-adaptive Ethernet port , support microSD /microSDHC/microSDXC card, up to 512 GB. IK10 Protection level. operating temperature -10 to +55 deg C, Day Night cameras, Tamper & Motion Detection feature, Vandal Proof & Motion detection,with IP 66, Connectors, Lens, Camera Mounts, Power Supply, I/O and all Ancillary Equipment & all accessories.
Supply, Installation, Testing and Commissioning of Outdoor Application Low Light IP Hi speed Dome type PTZ camera with 2 MP Resolution, mim 32X optical zoom, Low Light ,Day/Night, Wide dynamic range > 100 dB, Dual H.264 streaming, 0.05 lux, vandal resistant, 360° continuous pan, -0° to +90° tilt, 256 preset, IP66 rated with built in heater and blower, Mounted on Wall/Pole as per site requirement (including required accessories), UL listed as per detailed specifications. IEEE802.1X Security Protocol is must in all models IP cameras. Camera Shall also have Listing of (UL60960-1,IEC 600068-2-1,EN 55022 Class B , EN 61000-6-1, EN 61000-6-2 ).
Joy Stick to Control PTZ Cameras
Supply, installation,testing and commissioning of 80ch Network video recorder support 8HDD interface each support 10TB, RAID 0,1,5,10, support ANPR,Heat Map,People counting,smart Analytics. This should including with HDD and all necessary accessories for completeness of the systems.
Supply & Installing of 5M high above ground, 50mm / 65mm dia hot dip GI Galvanized heavy duty Pole with 70*130mm with base plate 220*220*12*3mm,suitable for outdoor applications & as per IS Standards with required accessories , civil work incuding but not limited to foundation works etc as required and approved.
Supply & Installing of Metal Telescopic bracket of hot dip galvanized iron material type for vertical drop of cameras.
Supply, laying, connecting , testing and commissioning of CAT 6A UTP LSZH armoured cable including terminations, connections & all labour and material etc. Complete as required & shall be as per relevant standards
CAT 6A UTP 2 mtr Patch Cord
Supply, laying, connecting , testing and commissioning of armored 12C Single Mode Optic Fibre LSZH Communication Cable including required termination & accessories required for completeness of the systyems.
43" LED monitor with HDMI capable of 24 x 7 operation, including software, hardware, mounting bracket and fitting and accessories to stream live video to Monitor with 16 / 32 camera display per screen.
Video Monitoring Station - Shall have the following configurations and features 1) Processor - Intel® Core i7® Processor 2) Memory: 16 GB DDR4 ECC RAM or better. 3) OS - Windows 10 Professional; 4) Networking - 2x 1GbE RJ45 Ports 5) HDD - 1 TB SATA 6) Graphics Card-4 GB or more 7) Supporting Two Monitors If vendor Server requirement is more than what is specified here, then required server configuration to be considered for Costing
ACCESS CONTROL SYSTEM
Swing Barrier (3 Standard lane + 2 wider lane) 12 pairs of infrared sensors, 20 – 60 passage frequency, 550 mm – 1100mm lane width, SUS304 stainless steel,thickness:1.2mm, Unauthorized personnel intrusion alarm Anti-trailing control ,anti-pinch function Anti-collision function, Fail safe for emergency situation Use for indoor and outdoor(water proof)
Boom Barrier Motor: DC brushless motor Barrier Boom: Length Mentioned below telescopic pole, right direction Rising Speed: 3 S Falling Speed: 3 S MCBF: 2,500,000 Power Supply: 220 VAC Protect Level: IP54 Barrier Housing Material: Cold-rolled sheet .
4.5 meters
Access Control Software: Supply, installation, testing and commissioning of Client Version Application Software for Access Control and attendance software for office area :- (Location :IBMS Room). Shall be Capable of Generating Multiple Reports in Excel format , such as Department wise / Door Wise / Card Wise / Day wise / Weekly, monthly reports etc.
Door Frame Metal Detector with 6 overlapped detection zones with 255 levels of zonewise sensitivity settings and in-built control panel with high detection sensitivity. DFMD detects both ferromagnetic and non-ferromagnetic metals, and is equipped with both audio and visual alarms,metal alarm count.
Hand held Metal Detector with adjustable detection sensitivity for different requirements. Also capable of detecting precious metals like gold, silver, rare metals, etc. Equipped with 2 modes - Audio alarm and vibration, Drop tested for 1m, low battery indicator and Standard 9V rechargable battery with power adaptor.
Supply, installation, testing and commissioning of Networked master access controller suitable to control and monitor support upto 64 Doors. Conroller shall be capable to connect to host/devices through TCP/IP netwrok and housed in polycorbonate box etc.complete as per requirement. Make - HID .
Supply, installation, testing and commissioning of Networked 2 reader access controller suitable to control and monitor support for 2 Doors. Conroller shall be capable to connect to host/devices through TCP/IP netwrok and housed in polycorbonate box etc.complete as per requirement. Make - HID.
Supply, Installation, testing and commissioning of 125 kHz proxymity card reader. Make - HID
Proxymity Card
Supply, installation, testing and commissioning of Electro magnetic lock with mounting accessories, door contact, buzzer etc.. Complete.
Supply, installation, testing and commissioning of Emergency release switch.
Supply, installation, testing and commissioning of Power Suppy units suitable for above controller, Emlock, buzzer, readers with battery backup as per requirement.
Supply, laying, testing and commissioning of 8C x 0.75 Sqrmm multistrand, ATC, FRLS PVC insulated shielded cable.
Supply, laying, testing and commissioning of 4C x 0.75 Sqrmm multistrand, ATC, FRLS PVC insulated shielded cable.
Supply, laying of 25mm FRLS PVC conduit
Supply & fixing of 100x40mm Aluminium floor raceway. Rate shall include floor cutting, fininishin as required at site.
FIRE ALARM SYSTEM
Addressable Fire Alarm Control Panel consists of display board which will have 160 Character Display with Touch key pad, Mother board 32 Bit Processor, In-built RS-485 Networking Circuit for peer to peer networking, In-built USB 2.0 Port, Loop Card having 254 devices of both detectors and modules in a single line circuit, SLC supports both Class A and Class B wiring Approval: UL Listed.
4 Loop Panel
Addressable Active Repeater Panel consists of display board having 160 Character Display with Touch key pad, Mother board which will have 64 Bit Processor, Inbuilt RS-485 Networking Circuit for peer to peer networking
Addressable Detectors with base with Binary coded address setting. Dual LED’s for 360° visibility Multi Sensor - Heat Cum Smoke detector
Addressable Detectors with base with Binary coded address setting. Dual LED’s for 360° visibility - Heat detector
Addressable Manual Call Point - Resettable type - with back box with Binary coded address setting with Status LED for 360° visibility.
Horn / Strobe wall / ceiling mounted type rated at 90 dBA @ 1m for Audible annunciation and 15cd minimum flashing at 1 Hz for visual indication.
Fault Isolator Module capable of monitoring shorted loop circuit and automatically restore communications
Response indicator for all detectors located above false ceiling.
POWER SUPPLY : 24VDC Power Supply with 5 amp rating, having LED indications for Power supply ON,battery Fail,Battery Charging,battery back up etc.
Supply and laying of FRLS PVC insulated 2 core 1.5 sq.mm. Armoured Copper Cable on ceiling / wall using fixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the Departmental Officers.
Supply of Addressable control relay module suitable to integrate with Access control and public address system with accessories as required at site.
Supply of Addressable Monitor module suitable to integrate with Access control and public address system with accessories as required at site.
Supply & Fixing of Metal junction box powder coated with fire red paint suitable to fix true ceiling detectors.
PUBLIC ADDRESS SYSTEM
Supply, installation, commissioning of Microprocessor based System Controller for connecting min 6 zones, with in built 6 zone router cum control with complete rack mounting accessories.Integration facility with Fire Alarm System, fire trigger alarm module, message manager, Speech Processor with relays for activating pre-recorded fire alarm messages with the required interface card to connect to the additional call zone stations and required interface units to connect amplifier and routers.it will vary as per client requirement.
Supplym installtion, testing and commissioning of 240W, Power Amplifiers. The amplifier shall adapt the maximum output power of each amplifier channel to its connected loudspeaker load, with free assignable output power per channel for a total maximum of 240 watt per amplifier, supporting 70 V or 100 V operation with direct drive capability. SNR >70dBA, THD > 0.1%, Frequency response 60 to 15kHz.
Supply & fixing of 27U network rack with enclosure
Supply, Installation, Testing & Commissioning of 6W RMS False Ceiling Mount Speakers with inbuilt 100V Line Matching Transformer, wide opening angle, optimized for music & speech applications with mounting clamps as per specifications
Box type 6W speaker shall be fixed rigid wooden enclosure designed for surface mounting with sound absorption lining at the inner rear section. Rate shall also inclusive of line matching transformer as required. Rate shall be same for fixing in ceiling / wall as required at site.
Microprocessor based Call Station With Stem Type Microphone
2 core x 1.5 sq.mm black colour twisted pair shielded multi strand ATC armoured FRLS cable in PVC conduit
NETWORKING
PASSIVE DATA
Supply, Laying, testing and commissioning of Unshielded Twisted pair CAT6A UTP Cable - Un Armoured (As per EIA /TIA Standards) 23 AWG Cable - Indoor through partly Tray / PVC Conduits- Only UTP Cable to be considered. Include Fluke Testing & Terminations.
Supply installation, testing and commissioning of 1U, 24 Port Fully loaded Jack / patch panel - Cat6A Cable Termination for Data, Voice & ELV.
Supply, installation, testing and commissioning of Cat6A RJ45 I/O Information Outlet with a separator to eliminate cross talk. Color to be confirmed with client before ordering - For IP Data & IP Voice, IP TV outlets. Include Fluke Testing & Terminations. Also inclusive of supply and Fixing of 1Set of 4 Module cover plate with frame only of White Colour shall only be considered under this item, but including with suitable size back box . Meant for Work stations. Suitable for Data & Voice information outlets like RJ 11 , RJ 45 & TV Socket Outlets. Since the mentioned items will be mounted on the table or wall based on site conditions, if mounted on the table, the necessary provisions shall be made by the furniture vendor. i.e. set up will be mounted on the on the table top itself .
Supply, Installation, Testing & Commissioning of Cat6a patch cord (With Moulded boots) - 1.5 Mtr Length.
Supply, Laying, testing and commissioning of 6 Core OM4 Multi Mode optical fiber cable (Corrugated Steel Tape Outdoor Armoured, Loose tube, Gel Filled, 9/125 Micron OS2). Include Fiber Splicing & Fluke Testing.
Supply, Laying, testing and commissioning of 12-fibre 1-U rack mount optical fibre panel, loaded with 6 Duplex LC-MM adapters, 12 MM OM4 pigtail, 1m each, and 12-core Fusion Splice Tray: Consisting of panel. Include Fiber Splicing & Fluke Testing.
6 Port Fully loaded LIU with all required accessories for complete functioning such as adapter plates, pigtails, adapter sleeves etc., for fibre cable connectivity at the network switch end
NETWORK RACKS
Supply, installation, Testing and Commissioning of 12U/15U IT Industry standard Rack with Black Powder Coated, Secured Lock with Key, with standard trays, Fans, Castors, Front Glazed Door & Rear MS Door.
Supply, installation, Testing and Commissioning of 42U (800mm x 1000 mm) Closed Rack with Perforated lockable front and back doors( 2 Nos), Fan at the top of the rack (Min. 90 CFM), AC Main Channels( Min 10 Points of 5.15A Sockets) vertical x 2, AC Distribtion Box, PDUs, Side Panels, Vertical Cable management high density rack at right and left, Horizontal Cable Manager, Cantilever Tray, Earthing Kit, Front Mounting Cable guides x 4, Front Cover at both sides, Adjustable Levellers with castor wheels, Mounting Hardware & all Acessories as required - Server Room
FRLS PVC CONDUITS
Supply and laying of heavy gauge rigid PVC conduit of 2mm thick with all conduit accessories PVC junction/pull boxes, G.I fish wire, fixing accessories etc, as required complete for earth cables mechanical protection ( Including wall chipping and covering with cement morter by providing chicken wire mesh wherever necessary and also GI Fish Wire. ) Note : For Earthing cables
32 mm dia Conduit
25 mm dia Conduit
PIPES
Supplying, laying, installation, testing and commissioning of Double Wall Corrugated (DWC) pipes complete with all fittings and accessories; Pipes shall be installed in Group Saddles; group saddles is in vendor scope and the same shall be supplied by the vendor - 50mm DWC Pipe for cables with couplers excavation, back filling, etc as per standard, complete with fittings and clamps including cutting and making good etc.
ACTIVE DATA
Layer2 Switches & Components
Supply, Installation, testing and Commissioning of Layer 2 Managed Switch- 24 ports of 10/100/1000 MBPS or more with 4 SFP Ports & Stacking Kit. Include all Accessories as required as per site specific requirement for complete functioning. All Accessories shall be of same Make as the OEM.
Supply, Installation, testing and Commissioning of Layer 2 Managed POE Switch- 24 ports of 10/100/1000 MBPS or more with 4 SFP Ports & Stacking Kit. Include all Accessories as required as per site specific requirement for complete functioning. All Accessories shall be of same Make as the OEM.
Supply, Installation, testing and Commissioning of SFP Modules - 1G
Layer3 Switches & Components
Supply, Installation, testing and Commissioning of Layer 3 Managed Switch- 24 ports of 10/100/1000 MBPS or more with 4 SFP Ports . Include all Accessories as required as per site specific requirement for complete functioning. All Accessories shall be of same Make as the OEM.
Supply, Installation, testing and Commissioning of SFP Modules - 1G
Wireless Access Points
Supply, Installation, testing and Commissioning of Access Point and All required Accessories,etc Support Wifi 6 Technology,Transfer speed Min 1400 Mbps. POE powered and Enhanced Security
ACTIVE VOICE
Supply ,installation ,Testing and commissioning of IPPBX System with 100 IP Ports
IP / SIP Licenses for IP Phones - 100 Users
IP Telephones(Receiption-2, Tidel office-2,IBMS Room-1, Substation and Security Room-4)
OFC to UTP Media Convertor - Media converter to convert 100/1000 MBPS BASE-TX ethernet twisted-pair signals to100/1000 MBPS BASE FX fast ethernet fiber signals, support full duplex ethernet mode, with two connectors one for transmission and other for reception, with RJ-45 port, two LED's for detecting the fiber link and ethernet link,fiber distance for multi mode upto 2 Km and single mode upto 15 Km, power input: 9V 1A Adapter and complete with other accessories. Unit shall be mounted in IP-66 housing.
3 Core x 1.5 sq mm unshielded, tinned copper , Twisted cable for power supply
INTEGRATED BUILDING MANAGEMENT SYSTEM
BMS WORKSTATION Intel core i7, 3 GHz processor, 16GB DDR3 RAM, 1TB SATA Hard Disk, DVD Writer, Lan Card 10/100/1000 base-T, Optical Mouse, 104 Keys Keyboard, Windows 7 / Windows 10 operating system. The workstation shall have Inbuilt graphics card and capable of connecting to dual monitor. The workstation to be supplied with latest Antivirus software._HP
Supply, Installation, Testing and Commissioning of 42" LED Monitor
Supply, Installation, Testing and Commissioning of 42" LED Monitor
Supply, Installation, Testing and Commissioning of A4 size Laser Printer suitable for the application, with driver software.
Supply, Installation, Testing and Commissioning of BMS SOFTWARE: Web enabled Graphical interface software based on MS Windows 10 / Latest. The system should be accessible from anywhere on LAN or WAN or Ethernet without additional licenses. The Communication protocol shall be Industry Standard BACNET Open Protocol. System should be scalable. The software shall be open system architecture type which facilitates interoperability with other system over BACNET IP with complete control and monitoring functions. Software shall be certified and complying to BACnet Advanced Operator Workstation. The software shall have facility to define alarms for certain consumption values. Software should be BACnet standard ISO 16484-5 protocol 1.13 or latest. Required gateway/open protocol software compatible to Modbus RTU/BACNet.
Supply, Installation, Testing and Commissioning of Client version BMS software for "Monitor & Control" application, complete with Advance Graphics for Realtime Graphical Depiction of the Statuses and Controls as per the Detailed IO Summary.
Client Desktop: Intel Core i5, 3 GHz Processor, 8 GB DDR3 RAM, 1 TB SATA Hard Disk, Lan Card 10/100/1000 base-T, Optical mouse, 104 keys keyboard, Windows 7 / Windows 10 Operating System. The Desktop to be supplied with latest anti virus software.
Supply, Installation, Testing and Commissioning of SMS & E-mail alarm notification module with unlimited user capacbility, SMS Paging, and Email Facility for transmitting specified alarms to designated personnel.
Supply,Installation,Testing & commissioning of Serial interface Modules (as a part of IO Module train) for High Level integration with following 3rd Party Equipment's as mentioned in the data point summary. Integration of the following equipment's and generating software for monitoring the parameters. Integration cost shall include charges towards development of graphic screens for all the equipment's listed below. The system will warrant an Exclusive, Dedicated Serial Interface Card / Controller for every single individual 3rd party system ( No other 3rd Party Integration shall be clubbed with any one integration ) The Interface controller shall be Capable to Integrate Open protocol systems on BACnet / Modbus / M-Bus Protocol Made available on serial RS 485 interface. Such Interface controller shall be Installed in a deticated enclosure and the same has to be connected with the BMS system through BACNET / IP protocol with following accessories
Integration of Fire Alarm System - 500 points
Integration of Digital Load Managers for metering.- 65 Nos - 12 points each (total 780 points)
Integration of AHU VFD - 4 Nos 10 points each
Integration of UPS - 2 Nos - 20 points each
Integration of VRF System - 43 ODU's -
Integration of VRF System - 67 IDU's
Integration of Diesel Generator - 2 nos
Integration of Lift - 3 nos
Integration of Solar System- 1 nos
Integration of STP
Integration of WTP
Integration of Access control system
Integration of Public Address
Integration of HT Panel
Bacnet / Modbus Communication Card for VRF by the OEM to integrate the VRF System with IBMS
Supply, Installation, Testing and Commissioning of DDC CONTROLLERS as per Data point summary. The Enclosures shall be MS Powder Coated , IP 55 Rating for indoor; and IP 65 rating for outdoor Installations. The Enclosure shall be provided with mounting accessories for DDCs / and or IO Modules and Serial Modules- such as DIN Rails, Elmex Terminals for Cable Terminations, Cable Managers, Dressings for internal cabling, ferruling, tagging etc. PSU shall also cater to power requirment of the Instrumentation, Actuators and other connected equipment. Enclosure Shall be Complete with pilot relays, fuses, overload protection relays, auxiliary power output socket etc. as required to complete the installation and intended usage. Shall have Bottom Knockouts for Cable entry, and side vents for ventilation DDCs, I O Modules and Serial Modules shall confirm to Tender specs and design intent.In a DDC Enclosure, there shall not be more than 6 controllers / expansion modules.
The Enclousere shall be provided with UPS as per enclousere power Requiremnet.
DDC CONTROLLERS : Automation stations / DDC Controller with I/O module etc., The controllers shall be NATIVE BACNET IP based. The controller shall be with 32 bit microprocessor, working in standalone or networkable mode, with real time clock and historical database & Peer to Peer Communication. The DDC's shall store programs and program parameters in non volatile memory. The DDCs shall be housed within a suitable powder coated MS enclosure complete with all protection, terminals, wiring and accessories as mentioned.
AHUs - 4 nos
Lift pressurisation fans - 1set
Toilet Exhaust Fans - 1 set
PHE Pumps - 1 set
Water Tanks - 1 set
Electrical Substation - 1 set
Electrical Panel Monitoring - 1 set
Supply, installation, testing & commissioning of Differential Pressure Switches to monitor AHU Fan Status with necessary coolectiong tube for suitable length and NO NC for the status of range of 500 pascal
Supply, installation, testing & commissioning of Differential Pressure Switches to monitor AHU Pre Filter Status with necessary coolectiong tube for suitable length and NO NC for the status of range of 300 pascal
Supply, installation, testing & commissioning of Return air temperature sensor - Duct mount type Air Temperature (Range: 0-50⁰C ) having pt1000 / Ni1000 output for Temperature and temperature accuracy +/- 0.5 ˚C & with accessories & all complete,
Supply, installation, testing & commissioning of Ambient Temperature and RH Sensor with Radiation shield - Outside Air Temperature & RH Sensor (Range: Temp 0-50⁰C & Humidity 0-100% ) having 0-10V DC output for Temperature & RH , Temperature accuracy +/- 0.5 ˚C, RH accuracy +/- 3% for 10-90% RH , to be installed in common return duct at AHU side with accessories & all complete.
Supply, installation, testing & commissioning of Level Switch For Water Tank
Supply and Run of 2 Core 1.0 SQ. MM, unarmored ATC conductor multi strand, Unscreened cable. Laid on Surface / On Cable Trays. All Cables shall be ferruled and tagged, and shall use lugs for termination at both ends.
Supply and Run of 2 Core 1.0 SQ. MM, unarmored ATC conductor multi strand, screened cable. Laid on Surface / On Cable Trays. All Cables shall be ferruled and tagged, and shall use lugs for termination at both ends.
Supply and Run of 2 Core 1.5 SQ. MM, Gunarmored ATC conductor multi strand, screened cable. Laid on Surface / On Cable Trays. All Cables shall be ferruled and tagged, and shall use lugs for termination at both ends.
Supply and Run of 3 core x 1.5 sqmm screened unarmored cable for Power. Laid on Surface / On Cable Trays. All Cables shall be ferruled and tagged, and shall use lugs for termination at both ends.
Supply and Run of 4 Core 1.0 SQ. MM, GI unarmored ATC conductor multi strand, screened cable.. Laid on Surface / On Cable Trays. All Cables shall be ferruled and tagged, and shall use lugs for termination at both ends.
Supply and Run of CAT 6 Communicatiuon cable.. Laid on Surface / On Cable Trays. All Cables shall be ferruled and tagged, and shall use lugs for termination at both ends.
Supply & laying PVC- FRLS conduits complete with all fittings and accessories-1 " PVC Conduit on wall
Supply & laying PVC- FRLS conduits complete with all fittings and accessories-19MM PVC Conduit on wall
Supply, installation, testing & commissioning of of Network Switch : 24 port layer Network switch with 10/100/1000 Mpbs
Supply, installation, testing & commissioning of 24U Rack - 19" type Equipment racks for mounting the Servers/ Switches in the BMS Equipment Room, & for mounting field mounted Switches at every Floor. Racks shall be complete with Modular Patch Panels for Patching the Field Cables ( Cu and FO) with the Edge Switches on floor as required. Racks shall be provided with Dual Power A&B, and should have 2 PDU Strips, Redundant Fans and Door to have Tamper Switch.
Any other accessories required to complete the system configuration as per vendor specific requirements i.e. Power supplies, Specific System cables etc. to complete the installation. Contractor to mention the quantity of the below items with cost apart from the below item if any other accessories are required , contractor to add the samePatch Panels,1mtrs Cat6 Patch Cords , LIUs, Pigtail Cables, 1 mtr LC to LC Single Mode Patch Cords, Labels, any other component to complete the design intent
EXTERNAL INFRASTRUCTURE WORKS
EXTERNAL INFRA - LAND DEVELOPMENT- PAVER , PLINTH PROTECTION, DRAINS
Providing and laying of 83mm thick factory made cement concrete interlocking paver block of M-40 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 75mm thick compacted bed of coarse sand / M-Sand, filling with machine compaction, joints filling with fine sand / M- Sand etc., all complete as per the direction of Engineer-in-charge. PARKING
Earth work excavating and depositing on bank with initial lead of 10 m & initial lift of 2m in Hard stiff clay, stiff black cotton, hard red earth, shales, murram, gravel, stoney earth and earth mixed with small size boulders.
Refilling with excavated earth other than sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification
Supplying and filling in foundation and basement with filling GRAVEL in layers of not more than 15 cm thick well rammed watered and consolidated complying with std spec.- Below paver block
Supplying and filling in foundation and basement with filling Stone metal 20 - 40m Sizes in layers of not more than 50mm thick well rammed watered and consolidated complying with std spec.- Below paver block
Cement Concrete 1:4:8 (One Cement, Four Crushed stone sand and eight hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete (The crushed stone sand to be used on concrete work shall confirm to gradation as per IS 383-1970)
Manufacturing, supply & fixing of precast kerb stone of size 400mmx259mmx200mm thick made of M 20 grade of concrete rectangular in shape with one corner chamfered by 100 mm x 100 mm as per approved design i/c cost of all material, labour and curing etc., complete. as per IRC 5758 - 1984.
Providing of placing RMC Reinforced Cement concrete of the following grades using Slag Cement, machine crushed coarse agrregates 20 mm and 12.5 mm, M sand, Water and admixture etc complete all for casting concrete elements of all shape and size and at all heights. (M25 Grade - 63mm tk )
Providing of placing RMC Reinforced Cement concrete of the following grades using Slag Cement, machine crushed coarse agrregates 20 mm and 12.5 mm, M sand, Water and admixture etc complete all for casting concrete elements of all shape and size and at all heights. (M35 Grade )
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification, Grade of Steel ( Fy )- Fe - 550 Confirm to IS : 1786: 1985.
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three M.Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the Engineer-in charge.
Providing Granolithic floor finish 40mm thick with Plain Cement Concrete 1:2:4 using 3 to 10mm ISS HBG metal, river sand and including rubbing the top surface smoothly thread lining if found necessary and curing etc. complete complying with standard specification and as directed by SIPCOT Officers including cost and conveyance of all material and labour, incidental charges, etc. complete.
Supplying and fixing mild steel grills for Drain Cover slab man hole cover grills etc., including priming coat etc., complete.
LANDSCAPE WORKS
(A) Soil Work :
Supplying, spreading and mixing red earth, and farm yard manure mixer with required base of chemical for control of pest and disease like Neem cake and carbo fureden and fertilizers for root regulator like DAP, Urea and superphosphate and for mind the mix cost of red earth sand, fertilizers and labour charges etc.,
(B) Lawn Work :
Making the lawn Mexican grass Turfing grass including forking the ground top dressing with sludge manure of fertilizers mixing with the same width forked soil, watering, weeding and maintenance for a period of 90 days or more from the actual date of completion of planting work till the grass forms a thick lawn free from weeds and fit for mowing including supplying good earth if need etc complete.
(C) PALMS VARIETY
Palm Tree Variety 10 to 12 feet ht. supplying and Planting, Labour including 3 Months Maintenance work.
(E) SPECIMEN PLANT
Specimen Plant Variety 3 to 4 feet ht. supplying and Planting, Labour including 3 Months Maintenance work.
(F) HEDGE PLANT
Hedge Plant Variety 1 feet ht. supplying and Planting, Labour including 3 Months Maintenance work.
(G) GROUND COVERS
Ground cover variety 2 to 3 feet ht. supplying and Planting, Labour including 3 Months Maintenance work
(H) Irrigation System
Earth work, PVC pipe, 360 degree Adjustable POP –Up Springler, Motor and Accessories Value
P AND C PROJECTS PRIVATE LIMITED (BID ID -1408526)
ABIRAMI ENGINEERING CONSTRUCTION AND CO (BID ID -1408668)
SSS HI TECH CONSTRUCTIONS PRIVATE LIMITED (BID ID -1410502)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid