Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.7 LAccepted-AOC SHOP NO 12 KHOPKAR APARTMENT KUMBHARAWADA URAN DISTT RAIGAD 400 702 | URAN | RAIGAD | MAHARASHTRA | 400702 | L1 | Accepted-AOC L1 | |
| 2 | L2₹11.7 L+₹30,215 (2.66%)Rejected-Finance | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹14.5 L+₹3.1 L (27.7%)Rejected-Finance SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L3 | Rejected-Finance BEING L3 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
15 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF THANE
Kolshet Road, Sandoz Baugh Post, Thane 400607
REPAIR OR MAINT OF SUMMER APPLIANCES WITH PLANT AND ACCESSORIES AT STN SITE P UNDER GE AF THANE
2020_MES_389534_1
8967/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
THANE
AS PER NOTICE OF TENDER
8 documents required · 8 mandatory
₹500
GE AF THANE
₹30,000
Yes
18 Feb 2021
24 Oct 2020
17 Dec 2020
24 Oct 2020
15 Dec 2020
27 Nov 2020
24 Oct 2020 - 27 Nov 2020
60 days
Amount
Taking down carefully existing storage type geyser 25/50 ltr capacity and disconnection of inlet and outlet water connection taking out all accessories inside the body removing nut bolt from base plate assembly cleaning of inside of stainless steel/copper tank with the help of brush, checking any leakage testing of each unserviceable parts/spairs for its functioning and replacement of unserviceable parts, re fixing the same after cleaning and making proper functioning to maintain proper water temperature, complete all as specified and directed by Engineer-in-Charge. Note: (i) The accessories/spare parts which are required to be replaced shall be measured and paid for separately as "Supply only" under respective items.
Taking out leakage storage type water heater 25/50 ltr capcity dismantling and taking out the inner tank, find out the leakage point brazing the leakage point and replacement of glass wool insulations using glass wool and refixing the same after testing all as directed by Engr-in-Charge.
Supply only heating element of capacity 2 KW including rubber washer, bolts, clamps etc for geysers of 50 ltr capacity of any type & make complete all as specified and as directed by Engineer-in-charge. Make : Dasspass/Theta/Elcon
Supply only heating element of capacity 1.5 KW including rubber washer, bolts, clamps etc for geysers of 25 ltr capacity of any type & make complete all as specified and as directed by Engineer-in-charge. Make : Dasspass/Theta/Elcon
Supply only non return valve brass chromium plated 15mm bore horizontal/vertical type suitable for 25/50 ltr capacity geysers complete all as specified and as directed by Engineer-in-charge. Note : The quoted rate shall deemed to include opening of existing GI fitting and cutting & threading of existing pipe line, if required for fixing new NRV.
Supply only pressure release valve (spring controlled) brass chromium plated for geysers of 25/50 ltr capacity of make and type complete all as specified and as directed by Engineer-in-charge.
Supply only Hot water outlet brass chromium plated connection 12mm bore 45cm long with chromium plated adopter and washer at both ends of required size complete all as specified and as directed by Engineer-in-charge.
Supply only heavy duty inlet PVC connection 450 mm long suitable for 15 mm bore GI pipe including PTMT nuts on both sides complete all as specified and as directed by Engineer-in-charge. Make : Prayag, Polytuf, Jindal
Supply only base plate assembly consisting of inlet and outlet CP brass pipe, thermostatic, CP brass pipe, drain plug, pressure release valve spring controlled and rubber gasket, bolts, washers etc as per existing pattern suitable for 25/50 ltr capacity geyser complete all as specified and as directed by Engineer-in-charge.
Supply only indicator lamp round/rectangular type as per site requirement, suitable for 25/50 ltr capacity geysers working on 230 volt AC supply complete all as specified and as directed by Engineer-in-charge. Make:- Siemens / L&T / C & S / AE
Supply only thermostatic switch (ISI marked) of range 0˚C to 80˚C suitable for 25/50 ltr capacity geyser complete all as specified and as directed by Engineer-in-charge. Make : Dasspass/Theta/Elcon
Supply only outer shell duly spray painted as per site requirement,made of 20 gauge MS sheet suitable for 25/50 ltr capacity geyser including rubber ring and screws and suitable make,size and shape complete all as specified and as directed by Engineer-in-charge.
M&L for preparing surfaces of geyser of capacity of 25/50 Ltrs, making dust free, scratching rust and old paint wherever required with sand paper and wire brush and spray painting with one coat of red oxide & one coat of synthetic enamelled paint of approved shade to complete all as specified and directed by Engr-in-charge. Make of Paint :- ASIAN / NEROLAC / SHALIMAR / BERGER
Supply only copper tank of 25/50 ltr capacity geysers as per site requirement, and suitable size and shape complete all as specified and as directed by Engineer-in-charge. Make :- Jindal / Bir / Leader
Supply only fusible safety brass plug of size and shape per site requirement, suitable for 25/50 ltr capacity geysers complete all as specified and as directed by Engineer-in-charge.
S&F in repair 15mm bore stop valve fancy type, chromium plated, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and as directed by Engineer-in-charge. Make : Zoloto / Prayag / SEIKO / NETA/ GEM
Equipment & labour for servicing of Split type AC 1.5 Ton / 2 ton, Window type AC 1.5, water cooler, refrigerator, and deep freezer of any size & capacity by taking out from its original location installed at any height,cleaning dirt, dust checking all the electrical connections and re fixing in its original position, cleaning cooling coil and condenser with chemical(Safe Foam Coil Cleaner) /soda water complete all as specified and directed by Engr-in-charge . Note-Servicing of machine of as and when on required basis.
Dismantling or taking out old defective compressor unit from existing window type AC OF CAPACITY 1.5 TR OF MAKE CARRIER / VIDEOCON / VOLTAS / LG and S&F same model with new sealed compressor reciprocating type of 1.5 TR capacity obtained from the factory outlet / authorised dealer under their replacement scheme alongwith test certificate and with one year guarantee card complete with connecting fitting and fixtures making brazing work and leak test and recharging refrigerant including soldering of copper pipes, replacement of capillary tube and dryer filter, replacement of foundation rubber bushes, nuts, bolts etc complete all as specified and directed by Engr-in-charge Make :- KIRLOSKAR /CARRIER/TECUMESH Note :- This item shall not include the capillary tube, cost of gas and gas charging which shall be measured and paid for separately under respective items.
S&F in replacement of air filter made out of Jute/PVC complete all as specified and directed by Engr-in-charge
S&F in replacement of overload protector including terminal cover and clips suitable for 1.5 TR capacity AC complete all as specified and directed by Engr-in-charge Make :- INDFOS/SHRIRAM/ RANUTRAL.
S&F in replacement of starting relay assembly including clips and terminal cover suitable for 1.5 TR capacity AC complete all as specified and directed by Engr-in-charge Make :- INDFOS/SHRIRAM/RANUTRAL.
S&F in replacement of starting capacitor 100/120 MFD including thimble for connection complete all as specified and directed by Engr-in-charge Make : HAVELLS / HPL / DUCATI / EPCOS/ NEPTUNE
S&F in replacement of running capacitor 36/45 MFD including thimble for connection complete all as specified and directed by Engr-in-charge. Make : HAVELLS / HPL / DUCATI / EPCOS/ NEPTUNE
S&F in replacement of thermostat switch including knob plate and screws etc complete all as specified and directed by Engr-in-charge MAKE-RANUTRAL/INDOFOSS/HONEYWELL.
S&F in replacement of motor Double shaft 1HP to 1.5HP Single phase, 3 speed, 230 volts including necessary fittings, capacitor, testing and commissioning complete all as specified and directed by Engr-in-charge. Make :- CROMPTON / AUE
S&F in replacement of wiring kit comprising of copper conductor cables for connections of assembly complete all as specified and directed by Engr-in-charge
S&F in replacement of cooling coil comprising of copper pipes of heavy grade of adequate size including necessary mild steel CP screws, brazing and connecting with existing system complete all as specified and directed by Engr-in-charge
S&F in replacement of condenser as per sample made out of copper tubes of heavy grade of adequate size including material and labour for replacement of mild steel CP screws, nuts/bolts, brazing and connecting with existing system complete all as specified and directed by Engr-in-charge
S&F in replacement of air flow control front grill made out of PVC heavy duty including fixing screws for existing window AC and other fixtures and fastening complete all as specified and directed by Engr-in-charge. Make :- CARRIER/VOLTAS/ NEPOLIAN / VIDEOCON
S&F in replacement of air flow and exhaust blower including tightening screws made out of PVC aluminum complete all as specified and directed by Engr-in-charge
S&F in repair base frame with body cover having all fitting / fixtures to accommodate all accessories made out of 1.25 mm thick mild steel plain sheet duly spray painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-charge Make of AC :- CARRIER / VOLTAS / VIDEOCON / WHIRLPOOL Make of Paint :- NEROLAC / ASIAN / SHALIMAR / BERGER
Dismantling and taking out of fan motor and refixing after rewinding with supper enamelled copper winding wire as per existing pattern including insulation, repair of shaft, including replacement of bushes, nuts, bolts, testing and commissioning complete all as specified and directed by Engr-in-charge
S&F in replacement of capillary tube for window type 1.5 ton AC including brazing and connecting with existing system complete all as specified and directed by Engr-in-charge.
Opening up and disconnecting the defective unserviceable sealed compressor unit of existing old WATER COOLER OF 40/80 LITRES, 120 Ltrs & 150 Ltrs CAPACITY OF MAKE VOLTAS / USHA/ BLUE STAR and replace with new compressor of water cooler storage type 40 ltr/hrs and supply and fixing new compressor obtained from the factory outlet / authorised dealer under their replacement scheme alongwith test certificate and with one year guarantee card complete all as specified and directed by Engr-in-charge Make :-LG /KIRLOSKAR /WHIRLPOOL Note :- This item shall not include the cost of gas and gas charging which shall be measured and paid for separately under respective items.
All as per srl item no -35 above but for water cooler of 120/150 Ltrs capacity.
S&F in replacement of relay suitable for compressor of water cooler with clips, relay cover and screws complete all as specified and directed by Engr-in-charge. Make- RANUTRAL / SHRIRAM / INDFOS / USHA.
S&F in replacement of starting capacitor 40/60/80 MFD complete all as specified and directed by Engr-in-charge. Make : HAVELLS / HPL / DUCATI / EPCOS/ NEPTUNE
S&F in replacement of running capacitor 6/10 MFD complete all as specified and directed by Engr-in-charge Make : HAVELLS / HPL / DUCATI / EPCOS/ NEPTUNE
Taking down and dismantling blower motor of water cooler and material and labour for rewinding with supper enamelled copper winding wire as per existing pattern including replacement of gun metal bushes, shaft, clamps including testing and commissioning complete all as specified and directed by Engr-in-charge.
S&F in replacement of fan blade of blower motor made out of aluminum alloy fixed with mild steel chromium plated screw etc complete all as specified and directed by Engr-in-charge.
S&F in replacement of 15 mm bore push type water tap brass chromium plated complete all as specified and directed by Engr-in-charge. Make :- JONSON / PARKO / KINGSTON / GEM SANITATION APPLIANCES
S&F in replacement of PVC flexible hose pipe, 32mm dia as in connections fixed at one end of waste water trap with clamp and other end left free to open at appropriate distance complete all as specified and directed by Engr-in-charge.
S&F in replacement of blower motor of capacity (1/32HP) including material and labour for replacement of mild steel clamps, rubber rings & capacitor of complete all as specified and directed by Engr-in-charge. Make- CROMPTON/ AUE/GE
S&F in replacement of condenser made out of copper tubes of heavy grade of adequate size including necessary screws, brazing to existing gas pipes & testing complete all as specified and directed by Engr-in-charge. Make -CROMPTON/ USHA/ AUE/GE
M&L for preparing surfaces of water cooler, making dust free, scratching rust and old paint wherever required with sand paper and wire brush and spray painting with one coat of red oxide & one coat of synthetic enamelled paint of approved shade to water cooler of capacity 40/80 litre of size 150 cm x 65 cm x 50 cm (approximate) complete all as specified and directed by Engr-in-charge. Make of Paint :- ASIAN / NEROLAC / SHALIMAR / BERGER
All as per srl item No 46 above but for water cooler of capacity 120 ltrs.
S&F in replacement of thermostat switch suitable for water cooler of any capacity including knob, plate and screws complete all as specified and directed by Engr-in-charge. Make- SHRI RAM/ INDFOS/WHIRLPOOL/VOLTAS.
S&F in replacement of capillary tube for water cooler of any capacity including brazing and connecting with existing system complete all as specified and directed by Engr-in-charge.
S&F in replacement of waste water drain tray for water cooler of any capacity including pvc clamp necessary screw and connecting with existing system complete all as specified and directed by Engr-in-charge.
Opening and disconnecting the defective unserviceable sealed compressor unit of old existing REFRIGERATOR OF CAPACITY 165/180/190/310/320 LTR of MAKE :– HAIR / VIDEOCON / KELVINATOR / LG of any make and type AC 230 volts single phase of for capacity of 165 ltr/180/190 ltr and supply and fixing new compressor obtained from the factory outlet/ authorised dealer under their replacement scheme alongwith test certificate and with one year guarantee card complete all as specified and directed by Engr-in-charge. Make :- KIRLOSKAR /CARRIER / WHIRLPOOL/LG Note:- This item shall not include the cost of gas and gas charging which shall be measured and paid for separately under respective items.
Opening and disconnecting the defective unserviceable sealed compressor unit of refrigerator of any make and type AC 230 volts single phase of capacity 310/320 ltr and supply and fixing new compressor obtained from the factory outlet/ authorised dealer under their replacement scheme alongwith test certificate and with one year guarantee card complete all as specified and directed by Engr-in-charge. Make :- KIRLOSKAR /CARRIER / WHIRLPOOL/LG Note:- This item shall not include the cost of gas and gas charging which shall be measured and paid for separately under respective items .
S&F in replacement of relay assembly suitable for 165/180/190/310/320 litre capacity refrigerator including relay cover, clips and screws complete all as specified and directed by Engr-in-charge. Make- RANUTRAL/INDFOS/WHIRLPOOL/VOLTAS
S&F in replacement of thermostat switch suitable for refrigerator capacity 165/180/190/310/320 litre including knob, plate and screws complete all as specified and directed by Engr-in-charge. Make- SHRI RAM/ INDFOS/WHIRLPOOL/VOLTAS.
S&F in replacement of condenser suitable for 165/180 litre capacity refrigerator made out of mild steel powder coated tubes of heavy grade of adequate size including necessary mild steel clamps and mild steel CP screws, brazing and connecting to existing gas system complete all as specified and directed by Engr-in-charge.
All as item No 55 above but of capacity 310/320 litre Refrigerator.
S&F in replacement of door gasket magnetic type suitable for refrigerator of capacity 165/180/190/310/320 litre including strip cover and mild steel CP screws complete all as specified and directed by Engr-in-charge.
S&F in replacement OLP 43/33 suitable for refrigerator capacity 165/180/190/310/320 ltr complete all as specified and directed by Engr-in-charge.
S&F in replacement of chiller tray of PVC suitable for refrigerator 165/180/190/310/320 litre capacity as per existing pattern complete all as specified and directed by Engr-in-charge.
S&F in replacement of PVC vegetable tray suitable for Refrigerator of capacity 165/180/190/310/320 litre as per existing pattern complete all as specified and directed by Engr-in-charge.
S&F in replacement of evaporator / freezer cabinet complete with freezer door made out of aluminum tubes of adequate size for refrigerator of capacity 165/180 litre including making connection with old system complete all as specified and directed by Engr-in-charge.
All as per srl item No 61 above but refrigerator of capacity 310/320 litre.
S&F Screw type bulb AC 230 Volt suitable for refrigerator of capacity 165/180/190/310/320 Lrs complete all as specified and directed by Engr-in-charge.
S&F in replacement of capillary tube for refrigerator of capacity 165/180/190/310/320 Litre including brazing and connecting with existing system complete all as specified and directed by Engr-in-charge.
S&F in replacement of door push button for refrigerator of capacity 165/180/190/310/320 Litre complete all as specified and directed by Engr-in-charge.
S&F in replacement of filter dyer for refrigerator of capacity 165/180/190/310/320 Litre, complete all as specified and directed by Engr-in-charge.
Opening and Disconnecting the defective unserviceable sealed compressor unit of DEEP FREEZER MAKE VOLTAS/BLUE STAR/ARCI of any make and type, AC 230 volts single phase of any capacity and supply and fixing new compressor obtained from the factory outlet / authorised dealer under their replacement scheme alongwith test certificate and with one year guarantee card complete all as specified and directed by Engr-in-charge. Make : Volts / Kirloskar / Tecumesh Note :- This item shall not include cost of gas and gas charging which shall be measured and paid for separately under respective item.
S&F in replacement of relay assembly suitable for deep freeze including relay cover, clips and screws complete all as specified and directed by Engr-in-charge. MAKE: INDFOS / VOLTAS.
S&F in replacement of thermostat switch suitable for deep freeze including knob, plate and screws complete all as specified and directed by Engr-in-charge. MAKE : WHIRLPOOL / VOLTAS / INDFOS.
S&F in replacement of door gasket magnetic type suitable for deep freeze including strip cover and mild steel CP screws complete all as specified and directed by Engr-in-charge.
S&F in replacement of OLP suitable for deep freeze complete all as specified and directed by Engr-in-charge.
S&F bulb AC 230 volt suitable for deep freezer all as specified and directed by Engr-in-Charge.
S&F in replacement of blower motor for deep frezeer of existing type and capacity including material and labour for replacement of mild steel clamps, rubber rings & capacitor of complete all as specified and directed by Engr-in-charge. Make- CROMPTON/ AUE/GE
Dismantling/taking out defective compressor unit from existing SPLIT TYPE AC CAPACITY 2/1.5 TR MAKE :- CARRIER / VOLTAS / VIDEOCON / LG / HITACHI / DAIKAIN / WHIRLPOOL and supply and fixing new company sealed compressor rotary type of 1.5 TR capacity obtained from the factory outlet / authorised dealer under their replacement scheme alongwith test certificate and with one year guarantee card complete including connecting fitting and fixtures making brazing work and leak test and recharging refrigerant including solering of copper pipes, replacement of foundation rubber bushes, nuts, bolts etc complete all as specified and directed by Engr-in-charge. Make TECUMSEH / KIRLOSKAR / CARRIER Note :- This item shall not include cost of gas and gas charging which shall be measured and paid for separately under respective items .
Dismantling/taking out defective compressor unit from existing SPLIT TYPE AC CAPACITY 2/1.5 TR MAKE :- CARRIER / VOLTAS / VIDEOCON / LG / HITACHI / DAIKAIN / WHIRLPOOL and supply and fixing new company sealed compressor reciprocating type of 2 TR capacity obtained from the factory outlet / authorised dealer under their replacement scheme alongwith test certificate and with one year guarantee card complete including connecting fitting and fixtures making brazing work and leak test and recharging refrigerant including solering of copper pipes, replacement of foundation rubber bushes, nuts, bolts etc complete all as specified and directed by Engr-in-charge. Make TECUMSEH / KIRLOSKAR / CARRIER Note :- This item shall not include cost of gas and gas charging which shall be measured and paid for separately under respective items .
All as per srl item No.75 above but of capacity 1.5 Ton Spilt type AC .
S&F in replacement of air filter made out of Jute/PVC suitable for split type AC complete all as specified and directed by Engr-in-charge.
S&F in replacement of combination capacitor of capacity 36+4, 36+6, 45+4, 45+6, 55+4, 55+6 MFD complete all as specified and directed by Engr-in-charge. Make : HAVELLS / HPL / DUCATI / EPCOS / NEPTUNE
S&F in replacement of capacitor 4 MFD complete all as specified and directed by Engr-in-charge. Make : HAVELLS / HPL / DUCATI / EPCOS / NEPTUNE
S&F in replacement of starting relay complete all as specified and directed by Engr-in-charge. Make RANUTRAL / INDFOS / SRIRAM
M&L for rewinding of blower motor (Evaporator motor) of split type AC with suitable size of copper winding wire as per existing pattern complete all as specified and directed by Engr-in-charge.
S&F of PCB plate for Split type AC of any make and type, of capacity 2TR/1.5 TR complete all as specified and directed by Engr-in-charge.
S&F in replacement of swing assembly motor as per existing model/make for split type AC 1.5/2TR unit, including rubber bush complete all as specified and directed by Engr-in-charge.
S&F in replacement of blower motor (Evaporator motor) for Split type AC including material and labour for replacement of mild steel clamps, rubber rings & capacitor of complete all as specified and directed by Engr-in-charge. Make- CROMPTON/ AUE/GE
S&F of condenser coil for 2/1.5 TR capacity Spilt type AC including welding/ brazing of pipe line, charging of refrigerant gas and testing of leakage as required including taking out existing condeser coil ,complete all as specified and directed by Engr-in-charge.
S&F,in replacement, of cooling coil for 2/1.5 TR capacity split type AC including welding/ brazing of pipe line, charging of refrigerant gas and testing of leakage as required including taking out existing one complete all as specified and directed by Engr-in-charge.
S&F,in replacement, of insulation (closed cell elastomeric insulation in tubing) over copper tubing wherever required using approved material as per manufacturers recommendation complete all as specified and directed by Engr-in-charge.
S&F,in replacement,of thermostat for 2/1.5 TR capacity split type AC including knob, plate and screws complete all as specified and directed by Engr-in-charge. MAKE : WHIRLPOOL / VOLTAS / INDFOS.
S&F in replacement of Indoor blower motor for Split type AC including material and labour for replacement of mild steel clamps, rubber rings complete all as specified and directed by Engr-in-charge.
S&F in replacement Remote control for Split AC of any make and any capacity or as per sample complete all as specified and directed by Engr-in-charge.
S&F in replacement of capillary tube for Spilt type AC including brazing and connecting with existing system complete all as specified and directed by Engr-in-charge.
S&F in replacement copper suction pipe line of suitable size (outer dia not less than 3/8'' (9.52 mm)) and gauge as per manufacturers recommendation complete with cutting, brazing work and insulation including fittings required at site complete all as specified and directed by Engineer-in-Charge.
S&F in replacement copper discharge pipe line of suitable size (outer dia not less than 1/4'' (6.35 mm)) and gauge as per manufacturers recommendation complete with cutting, brazing work and insulation including fittings required at site ,complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of housing (outer cover) for Split type AC as per sample ,complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Indoor cabinet for split type AC of any make and any capacity or as per sample.
S&F in replacement of Outdoor cabinet for split type AC ,complete all as specified and directed by Engineer-in-Charge.
M&L for PVC stickers of 20 mm of MES no made with computerized cutting to be pasted on equipment in proper shape as directed by Engineer in charge.Stickers for full MES No will be counted as one unit.For example"MES NO R-12345-S"
M&L for PVC stickers of 25 mm of MES no made with computerized cutting to be pasted on equipment in proper shape as directed by Engineer in charge.Stickers for full MES No will be counted as one unit.For example"MES NO R-12345-S"
S&F 8 mm dia post anchorage bolts for fixing of equipment on wall ,complete all as specified and directed by Engineer-in-Charge.
Flushing out the nitrogen gas from condensing coil AC 1.5 Ton capacity, repairs of leaking place by gas welding and recharging of referigent (R-12 & R-22).(Refregent will measured and paid in respective items) ,complete all as specified and directed by Engineer-in-Charge.
Flushing out the nitrogen gas from condensing coil AC 2 Ton capacity ,repairs of leaking place by gas welding and recharging of referigent (R-12 & R-22 ) .(Refregent will measured and paid in respective items) ,complete all as specified and directed by Engineer-in-Charge.
Flushing out the nitrogen gas from condensing coil Water cooler of capacity 150/150, 120/60 and 80/40 ltrs complete and repairs of leaking place by gas welding and recharging of referigent (R-12 & R-22 ) (Refregent will measured and paid in respective items) ,complete all as specified and directed by Engineer-in-Charge.
Flushing out the nitrogen gas from condensing coil Refrigerator of any any capacity and repairs of leaking place by gas welding complete and recharging of referigent (R-12 & R-22 ) (Refregent will measured and paid in respective items) ,complete all as specified and directed by Engineer-in-Charge.
Flushing out the nitrogen gas from condensing coil Deep freezer upto 400 ltr capacity ,repairs of leaking place by gas welding and recharging of referigent (R-12 & R-22 ) (Refregent will measured and paid in respective items) ,complete all as specified and directed by Engineer-in-Charge.
Supply only refrigerant gas R-134a of company sealed cylinder of capacity 61 Kg for charging water coolers/refrigerators complete all as specified and directed by Engr-in-charge. Make :- FREON / MEFRON ( Note :- Empty cylinder shall be contractor’s property and shall be returned back).
Supply only refrigerant gas R-22 of company sealed cylinder of capacity 61 Kg for charging in AC complete all as specified and directed by Engr-in-charge. Make :- FREON / MEFRON (Note :- Empty cylinder shall be contractor’s property and shall be returned back).
M&L for charging of Refrigerents R-410a for 1.5 TR Spilt type Air Conditioner to maintain required temperature as per site condition, complete all as specified and directed by Engr-in-charge.
M&L charging of Refrigerents R-32 for 1.5 TR Spilt type Air Conditioner to maintain required temperature as per site condition , complete all as specified and directed by Engr-in-charge.
S&F in replacement of indoor portable type condenser and evaprator unit having compressor of capacity not less than 1 TR , complete all as specified and directed by Engr-in-charge. Make- Bluestar Cat Part No-PC12DB
Removing the worn out old painted from surface of split unit external, scraping cleaning the old paint and repainting with proper colour as approved on external surface over a coat of red oxide primer by spraying painting , complete all as specified and directed by Engr-in-charge.
M&L for cutting and taking out the rusted/damaged portion of the sheet metal of AC/WATER COOLER /DEEP FREEZER /REFRIGERATOR of any capacity and providing new sheet of exiting gauge including welding/brazing as required and painting with two coat of red oxide primer , complete all as specified and directed by Engr-in-charge.
Supply in replacement of glass wool for any type of Water cooler /Deep freezer /Refrigerator/ Gyeser with rubber gasket packing with nut bolts etc , complete all as specified and directed by Engr-in-charge.
S&F in replacement of wall mounting type AC timer having Delay Time Facility, Auto & manual switch ,Suitable for window ,splits type AC of capacity 1.5/2 TR.Operating on AC input Supply: 230VAC +/- 15 %, 50Hz. Output: 230V, 25 Amp. Separate for 2 A/Cs having Protections for Over voltage (OV): Cutoff 270 V & Cut in 260 V Under voltage (UV): Cutoff 160 V & Cut in 170 V working for 24 Hours timer in 4 to 8 hours time intervals, complete all as specified and directed by Engr-in-charge.
S&F in replacement of 3 way backlite connector of capacity 20Amps,complete all as specified and directed by Engr-in-charge.
M&L for dismantling the indoor and outdoor units of Air conditioner Window/Split type completely,transporting to Workshop for carrying out repairs, transporting back to the site,reinstalling the same on the new /existing location complete all for satisfactory functioning of the equipment all as directed by Engineer-in-charge. Note 1.Spare replaced during the process of repair shall be measured and paid seperately under relevant item of Sch A. 2.Rates included in the cost of dismantling and transporting the AC to workshop and labour element for carrying out repairs. 3.The decision the Engineer -in -charge shall be final and binding on whether machine is required to be sent to workshop for repair or not.
All as per item no -115 above but for water cooler of any capacity.
All as per item no-115 above but for refrigerator/deep freezer of any capacity.
S&F in replacement MCB 6-32 Amps, Single Pole 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand / L&T / Havells / Schneider
S&F in replacement of sheet metal plug & socket DB, SP, with a two pin and earth plug with socket, 230 Volts with & including one MCB SP ‘C’ Curve 10 kA, 20 Amps complete all as specified and directed by Engineer-in-charge. Make of DB :- Legrand / Havells / L&T / Schneider Make of MCB :- Legrand / Havells / L&T / Schneider
S&F in replacement of PVC sheathed cable 3 core copper conductor of size 70/.0076mm, flexible for making connection of window/ Spilt type AC complete all as specified and directed by Engr-in-charge. Make :- Havells / RR Cable / NICCO / L & T / Finolex
S&F in replacement of PVC sheathed, cable 3 core with copper conductor of size 40/0.0076 flexible complete all as specified and directed by Engr-in-charge. Make- Havells / RR Cable / NICCO / L & T / Finolex
S&F in replacement of plug top 3 pin 5 Amps heavy duty for refrigerator/water cooler complete all as specified and directed by Engr-in-charge. Make :- LEADER / HAVELLS / LEGRAND
S&F in replacement of plug top 3 pin 15 amps heavy duty for Geyser & Air Conditioner, complete all as specified and directed by Engr-in-charge. Make :- LEADER / HAVELLS / LEGRAND
S&F raceways PVC duct cover 100mmx38 mm with 2 compartment ,2mtr length,all as specified and directed by Engineer-in-Charge.
Taking down submain wiring cable any number of runs alongwith earth wire from the existing concealed or surface conduit as directed
M&L for point wiring complete with 6 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed multistranded copper conductor cable 1100 volts drawn in and including concealed non metalic PVC rigid conduit (ISI Marked) medium grade 20mm dia, pipe hooks, elbows, junction covers and junction boxes terminated in existing sunken boxes including cutting chases in walls for conduits and making good disturbed surfaces of wall in CM 1:3 for mounting switches, sockets, fan regulator, covered with including 3mm thick bakelite plastic laminated sheet top cover fixed flush with wall using brass screws & cup washers including 2.5 Sqmm PVC insulated solid copper conductor wire as earth continuity to common earth and connecting to earth dolly for power point on independent board complete all as specified and directed by Engineer-in-Charge. Make of cable :- Havells, Finolex, Gloster & L&T Make of conduit :- Supreme, Prince, Kalinga
Supply and fixing in replacement of PCB circit for intelligent cooling ambient sensor suitable for 5.5 AC plant all as specified and directed by Engineer-in-Charge.Make Blue star.
Supply, installing, testing and commissioning in replacement of air ducting with GI sheet of suitable gauge as per IS:277 & IS: 655, including cutting and bending in shape and size as per site requirement and proper hanging/fixing arrangement, ducting where passes through non- air conditioned area, will be insulated with thermal insulation of 9 mm thick closed cell chemically cross linked, fire retardant polyethylene foam insulation of density 30 kg/cum,the thermal conductivity of the material should not exceed 0.035 W/mK at an average temp of 40 deg C., but where exposed to sky will be insulated with thermal insulation of 25 mm thick closed cell chemically cross linked, fire retardant polyethylene foam insulation of density 30 kg/cum, the thermal conductivity of the material should not exceed 0.035 W/mK at an average temp of 40 deg C & covered with glass cloth complete all as specified and as directed by Engineer-in-Charge. (Make of Insulating material : Paramount/a-flex /k-flex )
S&F in replacement of Acoustic insulation suitable for 5.5 AC plantall as specified and directed by Engineer-in-Charge.Make Blue star.
S&F in replacement of thermostate suitable for 5.5 AC plant all as specified and directed by Engineer-in-Charge.Make Blue star.
S&F in replacement of Propeller type PVC blade for condenser blower suitable for 5.5 AC plantall as specified and directed by Engineer-in-Charge.Make Blue star.
S&F in replacement of Non Woven Polyster Midea Enclosed by HDPE mesh Filter suitable for 5.5 AC plant all as specified and directed by Engineer-in-Charge. Make Blue star.
M&L for dismantling the indoor and outdoor units of Air conditioner Window/Split type completely, reinstalled in new location ,including connection commissioning complete all as directed as specified by Engineer-in-Charge.
NANGIA AND CO
cooltech engineering services
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .