| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.7 LAccepted-AOC INDEX NO D 1478 CE SC PUNE PLOT NO 44 11 KACHNAYAKANHALLI VILLAGE JIGANI HOBLI ANEKAL TALUK BANGALORE PIN 560 106 KARNATAKA STATE | 560106 | L1 | Accepted-AOC L1 | |
| 2 | L2₹52.9 L+₹10.3 L (24.2%)Rejected-AOC | L2 | Rejected-AOC NOT L1 | |
| 3 | L3₹52.9 L+₹10.4 L (24.3%)Rejected-AOC NH 17 MAIN ROAD BINAGA BAZAR KARWAR 581307 | KARWAR | UTTARA KANNADA | KARNATAKA | 581307 | L3 | Rejected-AOC NOT L1 | |
| 4 | L4₹54.7 L+₹12.2 L (28.5%)Rejected-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L4 | Rejected-AOC NOT L1 | |
| 5 | L5₹56.5 L+₹13.9 L (32.6%)Rejected-AOC 702 A1 SHREE PRASAD TAWADEWADI SHREE DATTAGURU PARK KUMBHARWADA URAN DIST RAIGAD MAHARASHTRA 400 702 | URAN | RAIGAD | MAHARASHTRA | 400702 | L5 | Rejected-AOC NOT L1 |
Tender Value
₹66.6 L
EMD Value
₹1.3 L
Closing Date
17 Jun 2025, 6:00 pmClosed
COL SAIKAT DE CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
SPECIAL REPAIRS TO ELECTRIC METER PANEL OF BLDG NO. P-01 TO P-07 AT KADAMBA VAMAM AND P-30 TO P-38 AT LITTLE BINAGA AND SPECIAL REPAIRS TO LT CABLES OF TECH BLDG AT NAD UNDER GE (SEABIRD) KARWAR
2025_MES_707868_1
85946
Open Tender
Civil Works
Item Rate
KARWAR
As per tender
9 documents required · 9 mandatory
₹1,000
GE(SB) KARWAR
₹1.3 L
Yes
1 Aug 2025
13 May 2025
19 Jun 2025
13 May 2025
17 Jun 2025
3 Jun 2025
Amount
Supply ,fix and complete installation in repair of wall mounted, powder coated, Indoor LT panel of 63 Amps capacity with provision of six single phase energy meter,IP 44 standard including aluminium bus bar ,01 No 63 Amps incomer TPN complete all as specified and directed. Outer shell shall be made of 2.00 mm CRCA sheet.
Incoming 1-63 Amps TPN,1 Nos. 2 Red Indicating Lamp with integrated LED Voltage: 230V AC-1 Nos. 3 Yellow Indicating Lamp with integrated LED Voltage: 230V AC-1 Nos. 4 Blue Indicating Lamp with integrated LED Voltage: 230V AC-1 Nos. 6-Multifunction Meter (LCD display), 3Ph, Parameters: V, A, F, meter 7- 32A Neutral Link, Channel Mounting, Outgoing 32 Amps SPN-06 Nos 10 Amps SP- 01 No Busbar 1-A Set of 200A 25kA Electrolyte Grade Aluminum Busbar 2-Aluminum Earth Busbar - 25x6mm
Supply ,fix and complete installation in repair of wall mounted powder coated, indoor LT panel of 125 Amp capacity with provision of four three single phase energy meter, IP 44 standard including aluminium bus bar, 01 Nos of 125 Amp incomer MCCB complete all as specified and directed. Outer shell shall be made of 2.00mm CRCA sheet Incoming 125 Amp MCCB-01 Nos Red indicating Lamp with integrated LED volt 230V AC-01 Nos Yellow indicating Lamp with integrated LED volt 230V AC-01 Nos Blue indicating Lamp with integrated LED volt 230V AC-01 Nos Multifunction meter (LED Display ), 3 Phase, Parameters : V,A,F, Meter 32A Neutral link, channel mounting
Outgoing SP 40 Amp -04 Nos SP 10 Amp-06 Nos Bus bar A set of 200A 25K Electrolyte grade Aluminium Busbar Aluminium Earth bus bar-25X6mm
Excavation in trenches not exceeding 1.5 m deep and not exceeding 1.5 m wide and getting out in soft/ loose soil for all as specified and directed.
Returning filling in leveling, watering and well ramming in layers not exceeding 25 cm thick all as specified and directed.
Removal of surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and directed.
Supply of flexible DWC- HDPE pipe (suitable for laying XLPE cables) of nominal diameter 63 mm conforming to IS 16205 part 24, laying the pipe under the ground and drawing the XLPE cable through the DWC pipe including joints, bends etc for proper fixing of the pipe complete all as specified and as directed.
Taking down carefully old unserviceable UG cable (LT/HT) of any size from the trenches/wall/pole and remove the unserviceable cable from site after affording credit depending on its serviceability state including removal of brick/PCC cable cover complete all as specified and as directed. Note : Excavation and earthwork shall be measured and paid for Separately
Supply and fix in repairs GI tubing 'Light' grade with all fittings for cable protection fixed on poles/walls/laid under roads crossing etc and made good the disturbed surfaces/ area all as specified and directed for size of pipe 50 mm bore
Supply, laying, jointing and testing of LT underground XLPE insulated screened PVC bedded, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade of cross-sectional area 16 Sqmm 4 core, conforming to IS-7098 (Part-I) of 1988 laid in trenches/wall/floors/ducts etc fixed with saddle and clamps or passing through pipes complete with cable and connection with proper thimbles, nuts, bolts and washers all as specified and directed. (Excavation & earth work, sand cushioning and PCC cover for cable protection will be measured & paid for separately)
Supply, laying, jointing and testing of LT underground XLPE insulated screened PVC bedded, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade of cross-sectional area 25 Sqmm 4 core, conforming to IS-7098 (Part-I) of 1988 laid in trenches/wall/floors/ducts etc fixed with saddle and clamps or passing through pipes complete with cable and connection with proper thimbles, nuts, bolts and washers all as specified and directed. (Excavation & earth work, DWC-HDPE pipe work for cable protection will be measured & paid for separately)
Supply, laying, jointing and testing of LT underground XLPE insulated screened PVC bedded, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade of cross-sectional area 35 Sqmm 3.5 core, conforming to IS-7098 (Part-I) of 1988 laid in trenches/wall/floors/ducts etc fixed with saddle and clamps or passing through pipes complete with cable and connection with proper thimbles, nuts, bolts and washers all as specified and directed. (Excavation & earth work, DWC-HDPE pipe work for cable protection will be measured & paid for separately)
Supply, laying, jointing and testing of LT underground XLPE insulated screened PVC bedded, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade of cross-sectional area 50 Sqmm 3.5 core, conforming to IS-7098 (Part-I) of 1988 laid in trenches/wall/floors/ducts etc fixed with saddle and clamps or passing through pipes complete with cable and connection with proper thimbles, nuts, bolts and washers all as specified and directed. (Excavation & earth work, DWC-HDPE pipe work for cable protection will be measured & paid for separately)
Supply, laying, jointing and testing of LT underground XLPE insulated screened PVC bedded, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade of cross-sectional area 70 Sqmm 3.5 core, conforming to IS-7098 (Part-I) of 1988 laid in trenches/wall/floors/ducts etc fixed with saddle and clamps or passing through pipes complete with cable and connection with proper thimbles, nuts, bolts and washers all as specified and directed. (Excavation & earth work, DWC-HDPE pipe work for cable protection will be measured & paid for separately)
Supply, laying, jointing and testing of LT underground XLPE insulated screened PVC bedded, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade of cross-sectional area 95 Sqmm 3.5 core, conforming to IS-7098 (Part-I) of 1988 laid in trenches/wall/floors/ducts etc fixed with saddle and clamps or passing through pipes complete with cable and connection with proper thimbles, nuts, bolts and washers all as specified and directed. (Excavation & earth work, DWC-HDPE pipe work for cable protection will be measured & paid for separately)
Material and labour for heat shrinkable straight through joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5/ 4 core 16 to 25 sq.mm. Note: Earth work, excavation, GI pipe etc shall be measured separately under relevant items of this schedule
All as per Item No.15 herein before but for cable of size 3.5 core 35 to 50 sq.mm.
All as per Item No. 15 herein before but for cable of size 3.5 core 70 sq.mm.
All as per Item No.15 above but for 3.50 core cable 95 Sq mm
Material and labour for heat shrinkable end termination joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5/ 4 core 16 to 25 sq.mm. Note: Earth work, excavation, GI pipe etc shall be measured separately under relevant items of this schedule
All as per Item No.19 herein before but for cable of size 3.5 core 35 to 50 sq.mm.
All as per Item No.19 herein before but for cable of size 3.5 core 70 to 95 sq.mm.
M & L for replacement of the old deteriorated existing bottom, external and internal steel surfaces of feeder pillar boxes/ panels/ boards of any description and in any position including removal of disintegrated & deteriorated paint either by hand scrapping or by blow lamps, applying necessary filler coat and stopping as required and applying two coats of synthetic enamel paint (grey in color) with using spray machine over a coat of red oxide primer on old prepared surfaces complete all as specified and directed by Engineer-in-Charge. NOTE: Rates quoted by the contractor are deemed to include fixing of cable glands, cable lugs and for writing/marking the MES /SM No and other relevant details with paint in the pattern and style as approved by the Engineer-in-Charge.
Material and labour for Preparation of old painted steel surfaces and applying two coats of synthetic enamel paint of approved shade on exposed surfaces of LT panel boards including writing / marking feeders all as specified and as directed.
Supply & Fixing in repairs flame proof material enclosed MCB distribution board Triple pole and neutral (TPN), AC, 440 volts, 8 way with aluminium busbar of rated capacity 100 amps and flameproof material door flush to the wall along with necessary cutting, plastering etc. and making good the disturbed surfaces in line to match with the existing wall surfaces complete all as specified and directed by Engr-in-Charge. Color -Smoke Gray, Material LM6 20 kg, IP 54 protection.
Disconnecting, dismantling of existing LT distribution panel and supply, fabricate, install, testing and commissioning of LT feeder panel board of suitable size, out door type double door, totally enclosed, duly compartmentalized with extended canopy at the top, dust and vermin proof made out CRCA sheet of 3.15 mm thick MS sheet mounting on MS angle iron 50x50x6 MM size , legs not less than 750 mm height, suitable foundation of 150 mm thick PCC (1:3:6) type C 2 with 100 mm offsets and panel board with front and back opening and locking arrangement compete two coats of finishing powder coated paint of approved shade over one coat of red oxide primer including one danger notice plate, Main aluminium strip bus bar of rated capacity 600 amps Triple Pole and Neutral (TPN), all busbar strips shall be covered with colour coded heat shrinkable sleeves including the following accessories and fitted in : - (a) Incoming: (i) MCCB high breaking capacity 4 pole 415 volt 25 KA breaking cap adjustable thermal & fixed magnetic release range 400 amp – 01 No (ii) Digital type Volt meter & amps meter with suitable capacity of CTs,LED indicator lamp RYB and other connecting accessories (b) Outgoing: (i) MCCB AC high breaking capacity 3 pole 415 volt 16 KA breaking cap adjustable thermal & fixed magnetic release range 125 amp – 4 Nos (ii) MCCB AC high breaking capacity 3 pole 415 volt 16 KA breaking cap adjustable thermal release range 100 amp of Make: Schneider/L&T/ GE/Siemens – 3 Nos (iii) MCB SPN 40 Amps - 3 Nos all as directed by the Engr In Charge.
M & L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm buried directly in ground vertically to a depth not less than 4.50 meter below normal ground level (with top edge of earth plate not less than 3.25 meter below ground level) connected to GI strip 32 mm x 6 mm main earthing lead by means of galvanized bolts, nuts and washers all as shown in electrical plate no 5 of MES Schedule Part-I (1991) with connected to earth test point & to main switch board /panel etc. all as specified and testing on completion with and including necessary excavation and earth work in any type of soil, earth electrode, earthing lead from electrode to equipment/substation/panel etc, adequate quantity of charcoal dust and common salt, PCC (1:3:6) type C-1 (using 20 mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6 mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20 mm graded black trap/granite/Basalt stone aggregate) 40 mm thick cover reinforced with 8 mm dia TMT bars 3 Nos both way with 12 mm dia round MS bar handle, GI light grade watering pipe 15 mm dia with funnel and wire mesh, and 40 mm dia GI light grade earth lead protection pipe, complete all as specified and directed. NOTE : Earth strip and its protection pipe up to and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth strip/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’.
SRI GURUPRASAD INFRATECH (BID ID -3318231)
ANKIT SHIP REPAIRERS AND SUPPLIERS (BID ID -3317855)
Shree Ayyappa Engineering (BID ID -3318750)
Sagar Electricals (BID ID -3326783)
K.G.SHANKER (BID ID -3315635)
NATIONAL ENGINEERING CORPORATION (BID ID -3318502)
Roy and Sons Infrastructures (BID ID -3319050)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .