Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹49.6 L
EMD Value
₹49,600
Closing Date
30 Jan 2026, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Divisional Officer
ROADS AND BUILDINGS DIVISION, GANJAM - II
Construction of R.O.B in lieu of L.C No-274 at Railway K.M55/5-7 in Between Station Rambha-Humma on Khurda- Palasa Main Line in the District of Ganjam under State Plan
2026_EICCL_125031_1
SC RandB GM-II-28/2025-26
Open Tender
Electrical Works
Percentage
60 days
Ganjam
2 documents required · 2 mandatory
₹6,000
₹49,600
Yes
7 Feb 2026
24 Jan 2026
31 Jan 2026
24 Jan 2026
30 Jan 2026
24 Jan 2026
24 Jan 2026 - 27 Jan 2026
PART-I :- SABULIA RAILWAY GATE - DP Mounted 11/0.4 KV 25KVA S/S with Boundry - Pole WPB GI160x160 11 Mtr
Pressure Channel 100x50x6mm, 2.8 Mtr 2 Nos with Galvanisation charges
DP Bracing Channel (100x50x6)mm (9.2 Kg/Mtr) Rs.10.00 added for Galvanistaion
AB Switch & HG Fuse mounting channel 75x40x6mm 2.8 Mts Long 4 Nos (6.8Kg/Mtr) with Galvanisation charges
Cantilever channel for supporting HG fuse 75X40X6mm MS Angle 1 mtr. Long 2 Nos. (6.8Kg/mtr) with Galvanisation charges
Cantilever channel for supporting HG fuse 50X50X6mm MS Angle 1 mtr. Long 2 Nos. (4.5Kg/mtr) with Galvanisation charges
Angle for cantilever arrengement for AB Switch & HG Fuse 50x50x6mm 2 Mts Long each, 2 Nos (4.5Kg/Mtr) with Galvanisation charges
DP Bracing Channel (50x50x6)mm 7Mtrs.(4.5 Kg/Mtr) Rs.10.00 added for Galvanistaion
Angle for mounting of LT distribution box 50X50X6mm 3mtr long each (4.5Kg/Mtr) with Galvanisation charges
Disc Insulator(T&C) 45 KN Polymer
H.W fitting(T&C) 45KN
11KV AB Switch 3 Pole, 200A
11KV HG Fuse 3 Pole, 200A
11KV Lighting arrester 9kva,10KA
LT Distribution Box with MCCB, Alluminium Busbar for single Bay with Kit kat fuse for 25KVA S/S
H.T Stay set (Complete) REC Contructed standard
HT Stay Insulator Type-C
HT Stay Clamp (1.9 Kg/Pair)
7/10 G.I Stay wire
55mm2AAA for Jumpering
PG Clamp for 55mm2AAA
Fish plate 50X8 mm, 0.28mtr long (0.97Kg/Mtr.)
G.I Pipe Earthing 40mm Dia medium gauge 03mtr long for Earthing device
Earthing Of Support Coil Type
G.I Flat(25x6mm) for Neutral & body Eathing of DTR
GI Nut, Bolt & washer
LT 3.5 Core, 50 sqmm PVC Cable (Unarmored)
Anticlimbing Device (G.I Barbed Wire 3 Kg per support)
Back Clamp for anticlimbing device 25x3mm.flat, 0.59Kg/Mtr, Flat of 0.510mtr length 4 Nos= (8x0.59x0.510)
Danger Board
Back Clamp for danger plate 25x3mm.flat, 0.59Kg/Mtr, Flat of 0.510mtr length 2 Nos= (2x0.59x0.510)
Sundries
Material for masonary ork for earth pit, Charcoal, Salt etc
Concreting of support CC 1:1.5:3,0.45 CUM@6400/- (L)
Couping with CC 1:1.5:3,0.1125 CUM @6400 (M)
Cement concreting for stay anchor plate with CC 1:2:4,0.2 [email protected] (N)
Construction of brick wall boundary wall with civil &MS metal & sand spreading and metal spreading to the new DSS (P)
Survey & Digitization of new DSS & its internals including its attributes (Q)
Survey & Digitization of MCCB/LTDB & its internals including its attributes (Q)
Plinth Mounted 11/0.4 KV 100KVA S/S with Boundry - Pole WPB GI160x160 11 Mtr
Pressure Channel 100x50x6mm, 2.8 Mtr 2 Nos with Galvanisation charges
DP Bracing Channel (100x50x6)mm (9.2 Kg/Mtr) Rs.10.00 added for Galvanistaion
AB Switch & HG Fuse mounting channel 75x40x6mm 2.8 Mts Long 4 Nos (6.8Kg/Mtr) with Galvanisation charges
Cantilever channel for supporting HG fuse 75X40X6mm MS Angle 1 mtr. Long 2 Nos. (6.8Kg/mtr) with Galvanisation charges
Cantilever channel for supporting HG fuse 50X50X6mm MS Angle 1 mtr. Long 2 Nos. (4.5Kg/mtr) with Galvanisation charges
Angle for cantilever arrengement for AB Switch & HG Fuse 50x50x6mm 2 Mts Long each, 2 Nos (4.5Kg/Mtr) with Galvanisation charges
DP Bracing Channel (50x50x6)mm 7Mtrs.(4.5 Kg/Mtr) Rs.10.00 added for Galvanistaion
Angle for mounting of LT distribution box 50X50X6mm 3mtr long each (4.5Kg/Mtr) with Galvanisation charges
Disc Insulator(T&C) 45 KN Polymer
H.W fitting(T&C) 45KN
11KV AB Switch 3 Pole, 200A
11KV HG Fuse 3 Pole, 200A
11KV Lighting arrester 9kva,10KA
LT Distribution Box with MCCB, Alluminium Busbar for single Bay with Kit kat fuse for 100KVA S/S
H.T Stay set (Complete) REC Contructed standard
HT Stay Insulator Type-C
HT Stay Clamp (1.9 Kg/Pair)
7/10 G.I Stay wire
55mm2AAA for Jumpering
PG Clamp for 55mm2AAA
Fish plate 50X8 mm, 0.28mtr long (0.97Kg/Mtr.)
G.I Pipe Earthing 40mm Dia medium gauge 03mtr long for Earthing device
Earthing Of Support Coil Type
G.I Flat(25x6mm) for Neutral & body Eathing of DTR
GI Nut, Bolt & washer
LT 3.5 Core, 50 sqmm PVC Cable (Unarmored)
Anticlimbing Device (G.I Barbed Wire 3 Kg per support)
Back Clamp for anticlimbing device 25x3mm.flat, 0.59Kg/Mtr, Flat of 0.510mtr length 4 Nos= (8x0.59x0.510)
Danger Board
Back Clamp for danger plate 25x3mm.flat, 0.59Kg/Mtr, Flat of 0.510mtr length 2 Nos= (2x0.59x0.510)
Sundries
Material for masonary ork for earth pit, Charcoal, Salt etc
Concreting of support CC 1:1.5:3,0.45 CUM@6400/- (L)
Couping with CC 1:1.5:3,0.1125 CUM @6400 (M)
Cement concreting for stay anchor plate with CC 1:2:4,0.2 [email protected] (N)
Construction of Plinth for new Plinth mounted DSS(O)
Construction of brick wall boundary wall with civil &MS metal & sand spreading and metal spreading to the new DSS (P)
Survey & Digitization of new DSS & its internals including its attributes (Q)
Survey & Digitization of MCCB/LTDB & its internals including its attributes (Q)
11KV Electrical Infra shifting - WPB 160x152 (34.6 KG/Mtr) 13Mtr-with base plate 300x300x12
11Kv V Cross arm (10.2Kg/each)
G.I Back Clamp for V cross arm (0.85Kg each)
11KV F Clamp 2.9 Kg
Top Bracket 100x50mm MS Channel (0.2Kg Each)
Disc Insulator (T&C) 45KN
H.W fitting(T&C) 45KN
11KV Pin Inulator Polymer
100mm2 AAAC
PG Clamp for 100mm2AAAC
11KV Lighting arrester (for 11KV XLPE Cable)
(75x40x6)MM MS Channel with Galavanistaion 1.2 Mtr long, 02Nos (@6.8Kg/Mtr) for road support of Las
Heat shrinkable Joiniting Kit for 3Cx35MM2 11KV XLPE Cable (Out door type)
3Cx35MM2 11KV XLPE Cable (Armoured) A2XFY
7/10 G.I Stay wire for support of XLPE Cable
11KV XLPE Cable clamp to hold support wire
Pole clamp for Eye hook for XLPE Cable
Eye hook for XLPE Cable
Suspension clamp with eye hook for XLPE Cable
Conductor dead end Clamp suitable for bare massenger XLPE areial bunched cable (25-70mm)
(25x4) mm GI Flat for earthing of XLPE Cable
GI pipe earthing 40 mm dia medium gauge (3.25mm thick ness) 3 mtr long for XLPE Cable & Las
Earthing Of Support Coil Type
H.T Stay set (Complete)
HT Stay Insulator Type-C
HT Stay Clamp (1.9 Kg/Pair)
7/10 G.I Stay wire
GI Nut, Bolt & washer
100X50X6mm,MS Channel for straight cross arm (1.2mx10pcs) (9.2Kg/Mtr) + + (0.2mx0 pcs) (9.2Kg/Mtr) for tapping & cut point pole+ Galvanisation charges
100X50X6mm,MS Channel for straight cross arm (1.8mx4pcs) for Guarding
No-6 G.I Wire (Dia 4.8mm)
EYE Hook for Guarding
GI pipe earthing 40 mm dia medium gauge 3 mtr long at both end of guarding
Anticlimbing Device (G.I Barbed Wire 3 Kg per support)
Back Clamp for danger plate 25x3mm.flat, 0.59Kg/Mtr, Flat of 0.510mtr length 4 Nos= (8x0.59x0.510)
Danger Board
Back Clamp for danger plate 25x3mm.flat, 0.59Kg/Mtr, Flat of 0.510mtr length 2 Nos= (2x0.59x0.510)
Sundries
Material for masonary ork for earth pit, Charcoal, Salt etc
Concreting of support CC 1:1.5:3,0.55 CUM@6400/- for 13Mtrs WPB Pole
Couping with CC 1:1.5:3,0.1125 CUM @6400 (M)
Cement concreting for stay anchor plate with CC 1:2:4,0.2 [email protected] (N)
Road Crossing of 11KV Underground cable 3Cx35 MMSQ 11kv XLPE Cable (armoured) A2XFY
Heat shrinkable Jointing Kit for 3CX35 MM2 11 KV XLPE cable (out door type)
Clamp for HDPE Pipe (cable raising)
Supply & Laying of PIPE HDPE 160 MM DIA PN4, PE 80 through HDD method. Scope of work also includes making Trenchless ducts with 160 mm Dia HDPE pipe casing using HDD machine including supply of HDPE pipe as per IS 4984, (Providing parabolic graph included in the scope)
Supply and installation of cable route marker including transportation from site/tent, excavation, refilling, disposing of malba, flooding with water, ramming/compacting of foundation as per standard specification and drawing.
Erection of 11KV DP with 2 Nos 13 Mtrs WPB Pole for cable raising=02 Nos - WPB 160x152 (34.6 KG/Mtr) 13Mtr-with base plate 300x300x12
Earthing Of Support Coil Type
100x50x6mm GI Channel (9.2Kg/Mtr) (2 Nos)
75x40x6mm GI Channel DP belting (6.8Kg/Mtr)
50x50x6mm GI Angle Cross Bracing (4.45Kg/Mtr)
GI pipe earthing 40 mm dia medium gauge 3 mtr long
Lighting arrester(12KV,10KA) Station Class
25x6 mm G.I Flat
H.T Stay set (Complete)
HT Stay Insulator Type-C
HT Stay Clamp (1.9 Kg/Pair)
7/10 G.I Stay wire
GI Nut, Bolt & washer
Anticlimbing Device (G.I Barbed Wire 3 Kg per support)
Back Clamp for danger plate 25x3mm.flat, 0.59Kg/Mtr, Flat of 0.510mtr length 4 Nos= (8x0.59x0.510)
Danger Board
Back Clamp for danger plate 25x3mm.flat, 0.59Kg/Mtr, Flat of 0.510mtr length 2 Nos= (2x0.59x0.510)
11KV H.W fitting(B&S) 70KN, 3bolt
11KV Disc Inulator Polymer(B&S) 70KN Polymer
CONDUCTOR 100SQmm2 AAAC
PG Clamp for 100mm2AAAC
No-8 G.I Wire (Dia 4.8mm) 0.131Kg/mtr.
Pin Inulator 11KV 5KN
Black paint
Yellow ColourPaint for Back ground
Sundries for survey tree cutting, small size nut bolt, Allm. Binding wire/ tape & danger board etc.
Material for masonary ork for earth pit, Charcoal, Salt etc
Concreting of support CC 1:1.5:3,0.45 CUM@6400/-
Couping with CC 1:1.5:3,0.1125 CUM @6400
Cement concreting for stay anchor plate with CC 1:2:4,0.2 [email protected] (N)
Shifting of LT Lines with 4x95+1x95+1x16mm2 XLPE AB Cable=0.39Km,3x50+1x35mm2 XLPE AB cable=0.33KM - WPB 160x152 (34.6 KG/Mtr) 9Mtr-with base plate 300x300x12
XLPE AB Cable (4x95+1x95+1x16) mm2
XLPE AB Cable (1x50+1x35)mm2
Suspension clamp with eye hook
Eye hook for (XLPE Cable Areial bunched Cable)
Pole clamp for EYE Hook for (XLPE Cable Areial bunched Cable)
Conductor dead end Clamp suitable for bare messenger XLPE Cable Areial bunched Cable (25-70 sq.mm)
LT Stay set (Complete)
Stay Insulator
Stay Clamp
7/10 G.I Stay wire
Piercing Connector
Neutral Connector
GI Nut, Bolt & washer
Earthing Of Support Coil Type
Anticlimbing Device (G.I Barbed Wire 3 Kg per support)
Back Clamp for anticlimbing device 25x3mm.flat, 0.59Kg/Mtr, Flat of 0.510mtr length 4 Nos= (8x0.59x0.510)
Danger Board
Back Clamp for danger plate 25x3mm.flat, 0.59Kg/Mtr, Flat of 0.510mtr length 2 Nos= (2x0.59x0.510)
Sundries
Cement concreting for stay anchor plate with CC 1:2:4,0.2 [email protected] (N)
Couping with CC 1:1.5:3,0.1125 CUM @6400
Concreting of support CC 1:1.5:3,0.375 CUM@6400/-
Dismantling Charges for Old Materials - Dismantling Charges for HT Pole
Dismantling Charges for LT Pole
Dismantling Charges for LT Cable
Dismantling Charges for AAAC
Dismantling Charges for 25KVA DTR
Dismantling Charges for 100KVA DTR
PART-II :- NH-16 TO SABULIA RAILWAY GATE - 11KV Electrical Infra Shifting (M+6) M+6 Tower
WPB 160x152 (34.6 KG/Mtr) 13Mtr-with base plate 300x300x12
Pole WPB GI160x160 11 Mtr
11KV Pin Inulator Polymer for M+6 Tower
GI Nut, Bolt & washer of different sizes for M+6 Tower
Supply of Anticlimbing Device for M+6 Tower
Back Clamp for Barbed wire anticlimbing Devicee 25x3mm.flat length of 0.510mtr for M+6 Tower
Danger Plate, 1 No for M+6 Tower
Back Clamp for danger plate 25x3mm.flat length of 0.510mtr 1 no for M+6 Tower
GI earth plate for earthing 25x6mm for M+6 Tower
Supply of Phase plate for M+6 Tower
Supply of G.I Pipe Earthing 40mm Dia for M+6 Tower
100X50X6mm,GI Channel for Guarding arrengements for M+6 Tower
Eye hook for M+6 Tower
No-10 GI Wire cross lacing(0.8Kg/mtr) for M+6 Tower
No-8 GI Wire (Dia 4.6) 0.131Kg/mtr 2mtr each pole connecting pole with Coil earthing
Top Bracket 100x50mm MS Channel (0.2 Kg each)
Disc insulator(T&C) 45 KN Polymer
H.W fitting(T&C) 45KN
11KV Pin Insulator polymer
100MM2 AAAC
11KV XLPE COVERED CONDUCTOR 100 SQMM, AAA
Tension Assembly Wedge Type with anchoring Clamp for 11KV Covered Conductor
IPC for covered Conductor 11 KV 100 Sqmm
Non metalic ties for 11KV Covered Conductor
Mechanical conductor with Heat shrink sleeve for 11 KV 100 Sqmm AAA Covered Conductor
PG Clamp for 100 Mm2 AAAC
MID SPAN JT FOR 100 SQMM INSL.AAAC-11KV
JT KIT END TERM for 11KV 100sqmm covered Conductor
TIE insulated helical f/11kv insl.. Cond.
Earthing Coil
H.T Stay set (Complete)
Stay Insulator
Stay Clamp or stud Clamp
7/10 G.I Stay wire
GI Nut, Bolt & washer
100X50X6mm,MS Channel for straight cross arm (1.2mx10pcs) (9.2Kg/Mtr) + + (0.2mx0 pcs) (9.2Kg/Mtr) for tapping & cut point pole+ Galvanisation charges
Anticlimbing Device (G.I Barbed Wire 3 Kg per support)
Back Clamp for danger plate 25x3mm.flat, 0.59Kg/Mtr, Flat of 0.510mtr length 4 Nos= (8x0.59x0.510)
Danger Board
Back Clamp for danger plate 25x3mm.flat, 0.59Kg/Mtr, Flat of 0.510mtr length 2 Nos= (2x0.59x0.510)
Sundries
Concreting of support CC 1:1.5:3,0.0.375 CUM@6400/- for 11 Mtrs WPB Pole (L)
Concreting of support CC 1:1.5:3,0.55 CUM@6400/-for 13 Mtrs WPB Pole (M)
Couping with CC 1:1.5:3,0.1125 CUM @6400.00 (N)
Earth work in excavation in all kinds of soil by mechanical means (Hydraulic excavator) / manual means including removing vegetation, dressing of sides and ramming of bottoms including dewatering (both forsub-soil water & rain water) wherever required by means of suiatable capacity of pump & pipe lines during excavation, concreting & also keeping the earth dry till the construction is overincluding backfilling with available earth etc. complete and disposal of surplus excavated Earth to the designated place by Local statutory Body as per direction of Engineer-in-charge and lift upto 1.5m, disposed earth to belevelled and neatly dressed. Disposal lead up to 100 meter. (O)
Earth work in excavation in all kinds of soil by mechanical means (Hydraulic excavator) / manual means including removing vegetation, dressing of sides and ramming of bottoms including dewatering (both forsub-soil water & rain water) wherever required by means of suiatable capacity of pump & pipe lines during excavation, concreting & also keeping the earth dry till the construction is overincluding backfilling with available earth etc. complete and disposal of surplus excavated Earth to the designated place by Local statutory Body as per direction of Engineer-in-charge and lift from 1.5m to 3.0M, disposed earth to belevelled and neatly dressed. Disposal lead up to 100 meter. (O)
Excavation above 3m (Q)
Providing and laying 225 or 300 mm thick dry rubble soiling with approved quality stones including filling gaps with small chips ramming with hand rammer etc. complete ®
Providing and laying in position cement concrete of grade M-10 including the cost of centring and shuttering- all level :1:3:6 (1 cement:3 coarse sand (Zone-III) :6 graded stone aggregate 20mm normalsize).(S)
Foundation and plinth in:rafts,footing,column,pedestals,beams,walls,slabs,machine and equipment foundation,pile caps,pipe support foundation. (T)
Providing and placing to correct line and level, in position, machine mixed reinforced cment concrete RCC of grade M20 with required slump for Raft/footings/column/beam/slab etc at all levels up to ground floorslab including vibrating,curing,providing construction joints, leaving cut-outs/ pockets,placing of inserts/ embedments, dewatreing wherever necessary etc., complete all as per drawing, but excludingcost of providing from work for all shapes and the cost of providing reinforcement, inserts/ embedments, as directed by the Engineer (U)
Providing all the materials including binding wires, cleaning, bending, cuttin, hoisting, placing in position, lapping and binding with 16 SWG annealed soft iron or tack welding reinforcement steel for all types of RCC/ Precast work irrespective of location & levels all as per drawings including steel scaffolding, handling and transporting from site stores, complete as directed by using High yield strenthdeformed bars conforming to IS 1786-HYSD Bars (V)
Material for masonary Work for earth pit, Charcoal, Salt etc including construction of earthing chamber and RCC slab cover of M+6 Tower (W)
Shifting of LT Lines with 4x95+1x95+1x16mm2 XLPE AB Cable=0.22Km,4x50+1x50+1x16mm2 XLPE AB cable=0.43KM - Pole WPB GI160x160 11 Mtr
WPB 160x152 (30.44 KG/Mtr) 9 Mtr-with base plate 300x300x12
XLPE AB Cable (4x95+1x95+1x16) mm2
XLPE AB Cable (4x50+1x50+1x16) mm2
Suspension clamp with eye hook
Eye hook for (XLPE Cable Areial bunched Cable)
Pole clamp for EYE Hook for (XLPE Cable Areial bunched Cable)
Conductor dead end Clamp suitable for bare messenger XLPE Cable Areial bunched Cable (25-70 sq.mm)
LT Stay set (Complete)
Stay Insulator
Stay Clamp
7/10 G.I Stay wire
Piercing Connector
Neutral Connector
GI Nut, Bolt & washer
Earthing Of Support Coil Type
Anticlimbing Device (G.I Barbed Wire 3 Kg per support)
Back Clamp for anticlimbing device 25x3mm.flat, 0.59Kg/Mtr, Flat of 0.510mtr length 4 Nos= (8x0.59x0.510)
Danger Board
Back Clamp for danger plate 25x3mm.flat, 0.59Kg/Mtr, Flat of 0.510mtr length 2 Nos= (2x0.59x0.510)
Sundries
Cement concreting for stay anchor plate with CC 1:2:4,0.2 [email protected] (K)
Concreting of support CC 1:1.5:3,0.45 CUM@6400/- (L)
Concreting of support CC 1:1.5:3,0.375 CUM@6400/- for 09 Mtrs WPB Pole (M)
Concreting of support CC 1:1.5:3,0.375 CUM@6400/- for 11KV WPB Pole (N)
Dismantling Charges for Old Materials - Dismantling Charges for PSC Pole
Dismantling Charges for LT Cable
Dismantling Charges for AAAC
Dismantling Charges for M+6 tower
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.05 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_2.pdf
PDF • 1.17 MB
Tendernotice_1.pdf
PDF • 0.14 MB
BOQ_577605.xls
BOQ • 0.96 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .