Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹19.4 LAccepted-AOC | ₹19.4 L Quoted ₹19.9 L | L-1 | Accepted-AOC L-1 |
| 2 | L-2₹21.0 L+₹1.1 L (5.47%)Rejected-Finance FLAT NO 93 POCKET 03 SECTOR 11 DWARKA NEW DELHI 110 075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | ₹21.0 L+₹1.1 L (5.47%) | L-2 | Rejected-Finance L-2 |
| 3 | L-3₹23.9 L+₹4.0 L (20.3%)Rejected-Finance N A | NEW DELHI | DELHI | 110001 | ₹23.9 L+₹4.0 L (20.3%) | L-3 | Rejected-Finance L-3 |
| 4 | L-4₹24.1 L+₹4.2 L (21.2%)Rejected-Finance | ₹24.1 L+₹4.2 L (21.2%) | L-4 | Rejected-Finance L-4 |
| 5 | L-5₹24.7 L+₹4.8 L (24.3%)Rejected-Finance | ₹24.7 L+₹4.8 L (24.3%) | L-5 | Rejected-Finance L-5 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
29 May 2025, 6:00 pmClosed
GE (AF) FARIDABAD
GE (AF) FARIDABAD
CERTAIN REPAIRS TO DRAIN, PATH, CULVERT, FENCING, LEAKAGE, SEEPAGE, OVERHEAD TANKS, ROOFING AND PERIODICAL SERVICES INCLUDING OTHER CONNECTED ITEMS AT AF STN NARIANA UNDER AOR OF GE (AF) FARIDABAD
2025_MES_707237_1
GE (FBD)/AF-13/2025-2026
Open Tender
Civil Works
Item Rate
180 days
Naraina
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) FARIDABAD
₹98,000
Yes
15 Jul 2025
8 May 2025
2 Jun 2025
8 May 2025
29 May 2025
15 May 2025
Amount
Demolition/Dismantling of Brickwork or stone/ boulder masonry, built in cement mortar incl all quoins, arches, pillars, etc,complete all as specified and directed .
M&L for Brickwork with subclass 'B' bricks (old size bricks), straight or curved on plan exc 6m mean radius, built in cement mortar (1:6) complete all as specified and directed.
All as per item No 02 above but except bricks.
M&L for brick work with sub class ‘B’ bricks (old size brick) straight or curved on plan to any radius in half bricks thick walls, built in cement mortar (1:4), complete all as specified and directed.
Taking down cement plaster of any description on concrete surfaces such as soffit of RCC slab, chajjas and brick walls, Ceiing etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed
M&L for 15mm thick ready mix plaster for external surfaces on brick/ concrete /stone wall surfaces including finishing the surfaces fair and even (without using extra cement) and smooth as per manufacture instructions, complete all as specified and directed.
M&L for 15mm thick ready mix plaster for internal surfaces on brick/ concrete/ stone wall surfaces including finishing the surfaces fair and even (without using extra cement) and smooth as per manufacture instructions, complete all as specified and directed.
M&L for 10 mm thick ready mix plaster for internal surfaces over concrete surface as on ceiling, chhajja, shelves etc to match with existing surfaces finish even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar (1:6) on brick Work or concrete surfaces including finished even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:4) on of brick work or concrete surface finish even and smooth (without using extra cement) incl WPC as per user manual, complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar (1:3) over concrete surface as on ceiling, chhajja, shelves etc to match with existing surfaces finish even and smooth without using extra cement, complete all as specified and directed. .
M&L for Removing loose concrete from chajjas, parapets, fascias, pillars, columns etc, not exc 2 sqm on plan and repairing the same with cement mortar (1:3)/Plain cement concrete type B-0 ,1:2:4 (12.5mm graded stone aggregate including required coat of white washing/ distempering/ weather proof paint / cement base paint to match the existing surface, complete all as specified and directed.
M&L for Removing vegetation growth/shrubs(girth up to 30 CM), cutting in brick wall/concrete surface upto triple storey building, carefully without damaging the existing soil, vent, water supply pipe and removing roots of plants completely and filling the gaps with PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate, finished surface with existing finshes including all scaffolding, ladder etc as required, surface shall n.exc. 0.36 Sqm each, complete all as specified and directed.
M&L for providing RCC nominal mix 1:2:4 incl necessary formwork and providing plaster in cement mortar (1:3) and two coats of finishes(as per existing finshes) over a coat of primer for RCC projected portion as in facias, fins upto a height of 50 cm facia etc incl demolition of existing and providing TMT bars if required, complete all as specified and directed. Note 1:- Length of fins, facias shall be measured irrespective of any thickness and height. Note 2:- Site for application is at various locations in patches and height varies up to 12 Meter, proper stable Scaffolding is must for working for the safety of resident of bldg and worker. Cost of all types of formwork, scaffolding and welded mesh shall deemed to be included in quoted rate.
M & L for preparation of new plastered surface and applying two coats of oil emulsion distemper on wall over one coat of primer including one layer of 3mm thick wall care putty on new plastered surface and obtain smooth finish using sand paper, complete all as specified and directed.
M&L for preparation of new plastered surfaces on wall/ceilling and applying two coats of weather proof exterior emulsion (water based) paint of dark colours/shade on walls (shade as approved by GE) over one coat of water based exterior primer to prepare the surface even and smooth on wall/ceiling surfaces, complete all as specified and directed.
M&L for one coat of Acrylic (exterior) emulsion paint over one coat of acrylic primer including one layer of 3mm thick wall care putty for exterior on old scraped wall/ceiling surfaces and obtain smooth finish using sand paper complete all as specified and directed. Note : Colour and make as approved by Engr-in-Charge.
M & L for preparation of old wall surfaces by removal of existing treatment and apply two coats of cement based paint over a coat alkali primer resistance including one layer of 3mm thick wall care putty on old scraped surfaces and obtain smooth finish using sand paper, complete all as specified and directed.
M&L for preparation of new plastered surface and apply two coats of cement based paint over a coat alkali primer resistance including one layer of 3mm thick wall care putty on new plastered surfaces and obtain smooth finish using sand paper, complete all as specifed and directed.
M&L for preparation of old surfaces by removal of existing treatment and apply one coat of cement based paint over a coat alkali primer resistance incl one layer of 3mm thick wall care putty on old scraped surfaces and obtain smooth finish using sand paper, complete all as specified and directed.
M&L for preparation of new plastered surface and applying two coats of oil emulsion distemper on ceiling over one coat of primer including one layer of 3mm thick wall care putty on new plastered surfaces and obtain smooth finish using sand paper, complete all as speicifed and directed.
M&L for two coats of Acrylic smooth exterior emulsion paint over one coat of acrylic primer including one layer of 3mm thick wall care putty for exterior on new plastered surfaces of wall/ceiling and obtain smooth finish using sand paper, complete all as specified and directed. Note : Colour and make as approved by Engr-in-Charge.
M&L for preparation of old surfaces by removal of existing treatment and applying two coats of oil emulsion distemper on wall/ceiling over a coat of primer including one layer of 3mm thick wall care putty on old scraped surfaces and obtain smooth finish using sand paper complete all as specified and directed.
M&L for preparation of old surfaces by removal of existing treatment and applying one coat of oil emulsion distemper on wall/ceiling over one coat of primer including one layer of 3mm thick wall care putty on old scraped surfaces and obtain smooth finish using sand paper, complete all as specifed and directed.
M&L for preparation of old surfaces by removal of existing treatment and apply one coat of cement based paint over a coat alkali primer resistance including one layer of 3mm thick wall care putty on old scraped surfaces and obtain smooth finish using sand paper, complete all as specified and directed.
M&L for complete removal of existing treatment on walls/ roof projections including facia, cornices etc by scrapping with mechanical sander/Paint remover machine (having mechanical vaccum mechanism) having RPM not less than 1500, sanding pad of 80 grit having dia of 7"/9" to make free from dust, loose paint etc by skilled labour, complete all as specified and directed.
M&L for applying two coats of oil bound distemper (OBD) over a coat of primer and including a layer of 2mm thick acrylic wall putty to achieve desired smoothness and eveness, complete all as specified and directed.
M&L for applying two coat of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company depot tinted) with silicon additives @ 1.43 litre / 10 sqm including a layer 2mm thick acrylic wall putty to achieve desired smoothness and eveness, complete all as specified and directed.
M&L for writing letters or figures (Block. Roman, Italic or Indian) not exceding 30 cm high complete all as specified and directed.
M&L for preparation of old/new treated plastered surfaces of wall by brooming down or steel wire brushing scrubbing down smoke soot, moulds, moss and efflorescence salts and treating oil and greasy spots removing dust, dirt and all loose scales of existing treatment using sand paper and applying two coats of weather proof exterior emulsion (water based) paint (in camouflage pattern) of dark colours/shade on walls (shade as approved by GE) over a coat of water based exterior primer incl one layer of 01 mm thick plaster of paris putty to prepare the surface even and smooth for exterior/interior on wall/ceiling surfaces complete all as specified and directed.
M&L for preparation of old surfaces of steel of any description , over 10 cm in width or girth not otherwise described applying one coat of synthetic enamel paint (ordinary tint), complete all as specified and directed.
M&L for preparation of old surfaces of steel of any description , n.exc 10 cm in width or girth not otherwise described applying one coat of synthetic enamel paint (ordinary tint), complete all as specified and directed.
M & L for preparation of old painted wooden surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint (first quality) complete all as specified and directed .
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, including dismantling of old sheets at an position complete all as specified and directed.
Dismantling of wall and ceiling boards (fiber, pulp, insulation etc.) or insulation boards / slabs / blankets, any thickness including cover fillet complete all as specified and directed.
S&F for 600x600mm plain board panel for ceiling 4.0 to 8.0 mm thick and including necessary Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having curled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre, complete all as specified and directed.
S&F PVC hollow panelling, 5 to 8 mm thick, on ceilling with necessary frame work in Design POPUP pattern and any colour & design approved by Engr-in-charge, inclusive of fixing on to ceiling including moulding end caps fixed with PVC sleeves and screws as required at site, complete all as specified and directed
S&F PVC hollow wall panelling, 7 to 8mm thick, any colour & design approved by Engr-in-charge, inclusive of fixing on to wall including moulding end caps fixed with PVC sleeves and screws as required at site, complete all as specified and directed
Taking down existing roof treatment of any description and any type, complete all as specified and directed.
M&L for Roughening surfaces of old concrete floor by picking, sweeping, cleaning and washing down with water to remove dust, including brushing with neat cement slurry @ 3.0kg of cement per sq.m etc, complete all as specified and directed.
M&L for screed bed of 15mm thick in cement mortar 1:4 on brick work or concrete surfaces, finish even and smooth (without using extra cement) including WPC as per user manual at any height etcm complete all as specified and directed.
M&L for preparation of roof surface and applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 Kg/Sqm including APP based polymeric membrane minimum weighing 3.6 kg/sqm and minimum 3 mm thick reinforced wih polyster non woven fabric (weight not less than 150 gms/sqm) laid on primed surface by forced application, joints to be tourched hot and width of overlaps shall not be less than 150 mm, complete all as specified and directed.
S&F Chicken wire mesh of size 12.5 mm and wire dia 0.51 mm (24 SWG) hexagonal construction, stretched firmly for roof treatment, complete all as specified and directed.
M&L for PCC (1:2:4) nominal mix, type B-0, using 12.5mm graded stone aggregate as in roof padding and surface finished even and smooth without using extra cement, complete all as specified and directed.
M&L for benching with PCC (1:2:4) type B-0 Using 12.5mm graded stone aggregate inclduing WPC, along side wall adjoining to roof in concave shape, including necessary formwork, complete all as specified and directed.
Removing plants / shrubs in duct wall, at junction with roots using herbicide chemical on existing brick work or concrete on multistoried building at any storeyed and any height, match the surface with existing surface using 1:3 cement mortar, complete all as specified and directed.
S&F for triple layered, rotational moulded polyetheylene water storage tanks (cylingrical verticlal with closed top) of 500 ltr capacity, hoisted and fixed in any position incl 20 mm dia ball float valve with aluminium fitting, GI nipple and any fitting, including dismantling existing water tank, complete all as specified and directed.
S&F for triple layered, rotational moulded polyetheylene water storage tanks (cylingrical verticlal with closed top) of 1000 ltr capacity, hoisted and fixed in any position incl 20 mm dia ball float valve with aluminium fitting,GI nipple and any fitting, including dismantling existing water tank complete all as specified and directed.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. for Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc and hoisting if required reconnecting and re-fixing in position. (incl writing in white paint of 150mm size " Tank cleaning on dt _______ " complete all as specifed and directed by Engineer in charge. (a) Tank Capacity exc 250 Ltr but n exc 500 Ltr.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. for Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc and hoisting if required reconnecting and re-fixing in position. (incl writing in white paint of 150mm size " Tank cleaning on dt _______ " complete all as specified and directed by Engineer in charge. (a) Tank Capacit exc 500 Ltr but n exc 1000 Ltr.
S&F 20mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed.
S&F for 20mm dia Nipple suitable for HDPE water tank.(Minimum weight 20mm 45gms) complete all as specified and directed.
S&F 20mm dia Unions. brass to connect iron to polyethylene and fixed, complete all as specified and directed.
S&F stainless steel pegset of six suitable size of length complete etc, complete all as specified and directed.
S&F for GI tubing 15mm bore medium grde with all fittings and fixed complete to wall and ceiling or laid in floors etc incl cutting chases in brick wall pinning in making good in CM 1:3 to facings where required, including taking down existing old U/S GI pipe, complete all as specified and directed.
S&F GI tubing 20 mm bore medium grade medium grde with all fittings and fixed complete to wall and ceiling or laid in floors , including taking down exisitng old U/S GI pipe, complete all as specified and directed.
M&L for Providing and laying factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar (1:3), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required, complete all as specified and directed.
M&L for preparation of stone, concrete surfaces of any description over 10 CM width or girth and applying one coat of plastic emulsion paint (Weather Coat) on footpath/colour tiles/ kerb stone etc (colour and pattren as per approved by EIC ) complete all as specified and directed.
Removing/cleaning of silt, mud,etc in culvert, drains etc of any width and length in soft/loose soil including depositing of removed material from site at a distance exc 500 m and n exc 1.5 KM deposited where directed by Engr-in-Charge, completed all as specified and directed.
M&L for PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in coping/benching and all other similar works including necessary formwork, complete all as specified and directed.
S&F in repair precast factory made polycrete (SFRC), medium duty, perforated drain cover, 75-100 mm thick, rectangle in shape upto 01 sqm area each with hole for drain, complete all as specified and directed.
Dismantling of fencing post or strut (wood, steel or RCC) any section, posts embeded in concrete, brick work, masonery etc, including taking out embeded portion in concrete, and making good disturbed ground complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for cement concrete (unreinforced) complete all as specified and directed.
S&F mild steel work as in posts and struts in fencing including cutting tops to shaps as directed, drilling holes, notching for wire, etc ; flat iron fillets (for securing wire mesh etc) embedded in concrete/mosnary complete duly tar painted and sanded the embedded portion of angle iron including all necessary drilling, bolting or riveting etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed
S&F rolled Mild steel plates plain square cut or notched (ordinary and counter sunk) forming holes, without any attachment.(Fe-410-W(Gde E-250)Quality-A) complete all as specified and directed.
M & L for preparation of new or previously untreated surfaces of steel of any description , over 10 cm in width or girth not otherwise described applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide primer, complete all as specified and directed.
S & F in repairs Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanized mild steel wire, staples or steel pins etc, including taking down old U/S exisiting barbed wire,complete all as specified and directed Note : Each line of wire shall be measured.
S&F in repair 900/600 mm dia concentrina spiral coil fencing with punched tape and 6 m max openable length, on wall with angle iron Y shaped with 9 horizontal RBT reinforced barbed wire studied with GI staples and GI clips to retain horizontal incl necessary bolts or GI barbed wire tied to angle iron, all complete as per direction of EIC, with reinforced barbed wire tape (RBT)/spring core (2.5 mm thick) wire of tensile strength of 165 kg/sqmm with tape (0.52mm thick) and weight 43.47 gm/m, including dismantling old U/S existing concertina coil, complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) including floor finishes/tiling work and disposal of debris, complete all as specified and directed.
M&L for 50 mm thick PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in plinth protection / path/ any paved area, complete all as specified and directed.
M&L for 75mm thick PCC type D-2, 1:4:8 (using 40mm graded aggregate) as in sub base, complete all as specified and directed.
M&L for coloured machine pressed precast concrete interlocking paver block, any shape and size confirming to IS 15658 -2006 of 60mm thickness (M-35 grade), with grey cement & pigment including 25mm thick sand filling, complete all as specified and directed.
All as per item No 72 above here in but except tiles. Note :- Interlocking tile shall be reused, retrieved from old serviceable tile
M&L for 80 mm thick machine cut precast concrete inter locking paver block with grey cement and pigment ,(M-40) grade any clours as approved by EIC /GE complete all as specified and directed
All as per item No 74 above here in but except tiles. Note :- Interlocking tile shall be reused, retrieved from old serviceable tile
M&L for sand filling under floors or in foundation including watering and consolidation, complete all as specified and directed.
M&L for chequered tiles of size 300 x 300 x 25 mm thick (colour and glazed approved by EIC) with grey cement and pigments laid over 15 mm thick screed bed in cement mortar (1:6) bedded and jointed in neat cement slurry, including dismantling, complete all as specified and directed.
Removing debris/excavated material to a distance exceeding 1.5KM but not exceeding 5 KM and depositing where directed at a level n. exc 1.50 m above the starting point complete all as specified and directed.
Note:- The work for periodical services shall include the following and the rates quoted by the bidders shall include the same :- (a) The work pertaining to periodical services shall be executed by the contractor as per MoU from authorized applicator through manufacturer of the materials like Exterior Emulsion paint, putty etc after approval by the GE. (b) The Contractor shall submit the documents “Memoradum of Understanding” (MoU) before starting the subject work with atleast one of the manufacturers mentioned in the contract documents. (c) Use of Scaffolding, trestles, ladders, cradles etc necessary for execution of work and protective measures as per site requirement. (d) Removing of nails, making good holes, cracks etc as per site requirement. (e) Work in patches and in narrow / widths, bands, cornices, plasters etc and cutting in edge of line where necessary. (f) Spreading and removing covering to doors, windows, floors, fittings etc to protect them from splashes. (g) Washing floors, cleaning glass, joinery, electric fittings, wirings etc. Drops and splashes of paint to be cleaned to the entire satisfaction of Engineer-in-Charge. (h) Removing and existing furniture for painting work and replacing the same post painting work, movable cupboard, chicks, blinds etc.
Note (Contd...): (j) Sample patch of 10 Sqm be prepared considering all the items of periodicals and shall be got approved from GE prior to carrying out further subject work. The work for periodical services shall include the following and the rates quoted by the bidders shall include the same :- (k) GUARANTEE OF PERIODICAL SERVICES: Periodical services against item No 22 & 28 of BOQ using mechanized equipment’s only executed under this contract are under the guarantee of contractor for 05 (Five) Years after the certified physical completion of work. Contractor is fully liable under this guarantee to rectify and redo all defective work intimated to him during this period including all type of materials and labour to the specifications catered for in the contract. In case contractor fails to rectify the defective work, Accepting officer shall get the rectification done as necessary at the risk and cost of contractor and recover the cost in full from the contractor. If the contractor consider that any additional treatment is required over and above that specified here in before in Schedule ‘A’, the same shall be carried out by the contractor without any extra cost to the Government.
M/S PRADEEP ENTERPRISES (BID ID -3308633)
M/S Rohit Enterprises (BID ID -3303024)
DEV CONSTRUCTION (BID ID -3303080)
M/S Yamin (BID ID -3300374)
S.R. Constructions (BID ID -3307806)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .