Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.7 LAccepted-AOC NO 6 A ANNASANDRAPALYA NEAR BIG MASJID BUILDING HAL VIMANAPURA POST BANGALORE 560017 | BENGALURU URBAN | KARNATAKA | 560017 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹3.6 L−₹30.2 L (89.4%)Rejected-AOC 20 1ST A CROSS SAI NAGAR AREHLLI UTTARHALLI BANGALORE 560 061 | BENGALURU URBAN | KARNATAKA | 560061 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹38.5 L+₹4.8 L (14.2%)Rejected-AOC NO 49 MSN NILAYAM 3RD CROSS HILL VIEW GARDEN TUNAHALLI SUBRAMANYAPURA POST BANGALORE 560061 | BANGALORE | BANGALORE | KARNATAKA | 560061 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹45.4 L+₹11.7 L (34.6%)Rejected-AOC | L4 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
7 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
BANGALORE
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINES MEG AND CENTRE BANGALORE 560042
CERTAIN REPAIRS TO JOINERY STAIRCASE ROOF AND MISCELLANEOUS B R REPAIRS IN THE MD OTM ACCN BUILDINGS UNDER THE AOR OF AGE B R MEG UNDER GE NORTH BANGALORE
2020_MES_403110_1
8496
Open Tender
Civil Works
Item Rate
90 days
BANGALORE
Class D category a(i)
6 documents required · 6 mandatory
₹500
Yes
₹80,000
Yes
25 Jan 2021
12 Dec 2020
9 Jan 2021
12 Dec 2020
7 Jan 2021
26 Dec 2020
12 Dec 2020 - 24 Dec 2020
60 days
Amount
Demolition of cement concrete and paving not exc 15 cm thick (below or above ground level) complete all as specified and as directed.
Demolition of brick work or stone / PCC /boulder masonry built in cement mortar or lime mortar including all quions, arches, pillars but excluding ashlar facing, dressed stone work of any description all as specified and directed.
Taking down cement plaster on brick / stone / concrete surface and hacking out joints hacking for key scrubbing down with water etc complete all as specified and directed
Dismantling floor, hearth or wall tiling including including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the the premises complete all as specified and as directed.
Dismantling of AC Sheets of any description as in roof covering including ridge, wind tie etc., complete all as specified and directed.
Dismantling single layer Mangalore pattern or similar tiles as in roofing complete all as specified and directed.
Dismantling single layer Mangalore pattern or similar tiles portions bedded in cement mortar.as in roofing complete all as specified and directed.
Dismantling plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
Dismantling timber scantlings 40 sq.cm and over in section, in any position in unframed work all as specified and as directed.
Dismantling battens for tiles, shingles etc, of any size including tilting fillets spaced exc. 15 cm all as specified and as directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
Rolled mild steel as in main and cross beams, hip and jack rafters; purlins where connected to common rafters, running rails and guides for sliding doors; fixed with angle cleats or other connected plates conforming to Fe-410W (Gde E-250) quality-A complete all as specified and directed.
Rolled Mild steel work as in hand rails, half round or other stock section or core for wooden hand rail straight portion, drilled and counter shunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc., flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 all as specified and as directed.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws as specifed and as directed.
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tenisile strenth of 550 Mpa as in roof covering cladding to wall, pre fixed with self taping screwes as specified and as directed.
False ceiling with grid suspended system of size 600 x 600mm with standard sections consisting of main runner 29 x 24.7 x 0.8mm, cross tee 29 x 24.7 x 0.8mm and wall angle 22.2 x 22.2 x0.65mm, ceiling suspended with 3mm dia GI wire hanger fixed with steel dash fastner, butter fly clips, hold down clips etc (main runner, cross tee & wall angle of MS galvanised with PPPCGS) including 4mm thick HPSC self textured design pre primered non asbestos fibre cement building boards fixed to false ceiling including one coat of distemper complete including taking down old existing ceiling of any description complete all as specified and as directed.
GI frame work for seam less ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to sorrounding wall using nylon sleeves and screws at 450 mm centre to centre/ intermediate channel 0.90mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900 mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section(not exc. 1.2m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre,hangers 6 mm dia GI (Up to 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size 60 mm long, ceiling boards 8 mm seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous Contd/-- 1.18
Contd/-- 1.17 and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having philips head with under head cutter at 200mm centre to centre including finishing the joint of face board with specially formulated jointing compound and 48mm wide fibre tape to provide seam less finish, incl necessary preparation of new surface and apply two coats of oil bound distemper over a coat of alkali resistant primer on ceilings including removal of existing false ceiling complete all as specified and as directed.
Brick work with sub class 'B' bricks built in CM(1:6), straight or curved on plan exc 6 mtr mean radius, using old size bricks complete all as specified and as directed.
All as per Sl Item No. 1.19 above but except bricks. NOTE:- Serviceable bricks as obtained from Sl Item No. 1.02 above shall be reused.
Plain Cement Concrete type B0 (1:2:4) using 12.5mm graded stone aggregate as in roof kerbs or mud stops, rounded or chamfered on edges in chajjas etc complete all as specified and directed.
15mm thick rendering on brick or concrete surface in cement mortar (1:6) and finishing the surface with even and smooth without using extra cement complete all as specified and directed.
Rendering 15mm thick consisting of two coats of 5mm thick in CM(1:4) over a coat of 10 mm thick in CM(1:4) mixed with water proofing compound as per manufacturers instructions finishing the surfaces even and smooth without using extra cement including necessary scaffolding complete all as specified and directed. NOTE:- WPC will be measured and paid separately under reelvent items.
Rendering 5 mm thick on ceiling /concrete surfaces in CM (1:3) surfaces finished even and smooth without using extra cement on ceiling complete all as specified and directed.
Supply only integral liquide water proofing compound all as specified and as directed.
Plain Cement Concrete (1:2:4), type B-0 using 12.5 mm graded stone aggregate as in floors 25mm thick, as in sub base to floor complete all as specified and as directed.
Matt finished rectified digital ceramic floor tiles of size 600 x 600 x 9-10mm thick as in floors set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10mm thick screed bed in CM(1:6) complete all as specified and directed MAKE :- Satin series of kajaria or techno commercially equivalent of Somany/Navin/Jhonson
All as per Sl Item No 1.27 above but in skirting set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10mm thick rendering in CM (1:4) on brick or concrete surfaces finished rough to receive wall tiles complete all as specified and directed.
Vitrified ceramic tiles 8-10mm thick (square / rectangular) polished, area of each tiles not exc 0.36 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick screed bed in CM (1:4) for laying floor finishes complete all as specified.
Vitrified colured ceramic tiles 8-10 mm thick (square/rectangular) polished area of each tile n.exceeding 0.36 sqm as in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles over 10 mm thick backing coat in CM(1:4) complete all as specified and as directed.
Full bodied vitrified tiles 15mm thick with double nosing and tread lines suitable for steps fixed in steps and similar works set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10mm thick screed bed in CM(1:6) complete all as specified and directed. MAKE:- Endura series of HR Johnson or techno commercially equivalent of Kajaria/Somany
All as per Sl Item No. 1.31 above but in vertical surfaces such as skirting / dados / risers etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick rendering in CM (1:4) on brick or concrete surfaces finished rough to receive wall tiles complete all as specified and as directed.
Plain Cement concrete (1:4:8), type D2, using 40mm graded stone aggregate as in sub bases of floors, 100mm thick, complete all as specified and directed.
75 mm thick plain cement concrete 1:3:6 type C2 (using 40 mm graded stone aggregate) as in paving/ plinth protection laid in alternate bays (not exceeding 2 sqm each) finishing the concrete surface even and smooth at top without using extra cement and providing joints throughout the thickness of plinth protection, filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight all as specified and directed.
Chequerred cement concrete tiles 300x300x25mm thick set, jointed and pointed in neat cement slurry with grey cement and pigment to match the colour of tiles over 20mm thick screed bed in CM (1:4) complete all as specified and directed.
Machine pressed (rubber moulded) precast concrete interlocking paver blocks any shape and size conforming to IS 15658-2006 of 60mm thickness, of M-35 grade with grey cement and pigment fixed over and inculding 50mm sand cushioning complete all as specified and directed.
Preparation of new or previously untreated steel and iron surfaces of any description not other wise described over 10cm width or girth and applying two coats of synthetic enamel over a coat of red oxide primer, complete all as specified and directed.
Preparation of newly plastered wall surfaces of any description and applying two coats of oil bound distemper over a coat of alkali resistent primer over two coats of wall care putty complete all as specified and directed.
Complete removal of existing treatment and applying two coats of oil bound distemper over a coat of alkali resistent primer over two coats of wall care putty complete all as specified and directed.
Preparation of newly plastered ceiling surfaces of any description and applying three coats of white wash complete all as specified and directed.
Preparation of newly plastered surface of wall and applying two coats of cement base paint over one coat of alkali resistant primer complete all as specified and as directed.
Taking up or down steel tubing 20 mm dia and connections including cleaning for refixing or removal to store all as directed.
Taking up or down steel tubing 25 mm dia and connections including cleaning for refixing or removal to store all as directed.
20mm dia medium grade Galvanised iron tubing with all fittings and fixed to wall, ceiling or laid in floors etc complete all as directed.
25mm dia medium grade Galvanised iron tubing with all fittings and fixed to wall, ceiling or laid in floors etc complete all as directed.
Dismantling water tanks and removing to store (exc. 250 and not exc. 500 ltr capacity) complete all as specified and as directed.
Dismantling water tanks and removing to store (exc. 500 and not exc. 1000 ltr capacity) complete all as specified and as directed.
Rotational moulded polythene water storage tank (cylindrical vertical with closed top) with ISI mark embosed on it, hoisted and fixed in position complete all as specified in SSR part I capacity of tank 500 ltrs capacity complete complete all as specified and as directed.
All as per Sl Item No. 1.48 above but except tanks.
Rotational moulded polythene water storage tank (cylindrical vertical with closed top) with ISI mark embosed on it, hoisted and fixed in position complete all as specified in SSR part I capacity of tank 1000 ltrs capacity complete complete all as specified and as directed.
All as per Sl Item No. 1.50 above but except tanks.
20mm dia Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed in repairs (Min weight 20mm-210 gms) all as specified and as directed.
Gun metal gate or globe valves 20 mm dia, with iron wheel head screwed both ends for iron pipe and including taking down old gate valve all as specified and as directed.
Gun metal gate or globe valves 25 mm dia, with iron wheel head screwed both ends for iron pipe and including taking down old gate valve all as specified and as directed.
Demolition of existing roof treatment of any type including cement plaster 10 mm thick and PCC 25mm thick and providing screed bed/rendering 10mm thick in CM (1:4) mixed with and including supply of approved water proofing compound as per manufacturers instructions over and including 25mm thick (average) PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) by removing all loose gravel, dirt, oil, grease and foreign materials by jet or dry air, cleaning the surfaces mechanically or by grinding to make it smooth and providing 50mm x 50mm coving at the corners with PMC mortar as above, and applying APP modified water proofing membrane as per IS 1654-2017/IS 16352-2017 mineral finish, 3mm thick and weighing not less than 3.60kg/Sqm reinforced with non woven polyster/HMHDPE matt black finished over compatible primer/bonding bitumen @ 0.40 Litr/Sqm and torch applications of membrane with 75mm side overlap and 100mm end lap after necessary preparation of surface complete as per manufacturer's instructions and applying a coat of solar reflective bituminous aluminum paint on top @ 0.10 litre/sqm complete all as specified and directed.
Taking down chowkat (without taking of shutter from the frame) not exc 1.5 sqm each including making good the disturbed surface in PCC 1:2:4 type B0 or CM 1:3 all as specified and directed
Anodised aluminum powder coated (of any shade/colour as approved by GE ) ventilators of size 600 x 900 mm with adjustable 4mm thick figured glass louvers, fixed in qtr portion, without sash bars, aluminum section weighing 0.55 kg/m including necessary jointing cleats, glazing clips, rubber packing, anodised aluminum snap beading, screws, including stainless steel wire cloth 0.36 nominal dia of wire and average width of aperture 1.18mm including complete etc all as specified and directed.
K. VENKATESH NAIDU
PRAGATHI BUILDERS
Atom Engineers and Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .