Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹70.3 LAccepted-AOC | L-1 | Accepted-AOC Lowest bidder for the subject work. | |
| 2 | L-2₹77.5 L+₹7.2 L (10.2%)Rejected-Finance | L-2 | Rejected-Finance other than the lowest bidder | |
| 3 | L-3₹79.9 L+₹9.6 L (13.7%)Rejected-Finance | L-3 | Rejected-Finance other than the lowest bidder | |
| 4 | L-4₹81.5 L+₹11.2 L (15.9%)Rejected-Finance 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | L-4 | Rejected-Finance other than the lowest bidder | |
| 5 | L-5₹96.0 L+₹25.7 L (36.6%)Rejected-Finance 84 A VIJAY NAGAR COLONY LALGHATI PO NAYAPURA BHOPAL 462032 | 462032 | L-5 | Rejected-Finance other than the lowest bidder |
| Sl No | Description | Qty | Unit | RAJPATI CONSTRUCTION L1 | M/S RAKESH TRADERS L3 | Bharat Sales Corporation L4 | POONAM ELECTRIC INDUSTRY L5 | RUHI ASSOCIATES L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply,fixing,testing and commissioning of Digital Power Meters
A). All the electrical Parameters with Harmonic Measurement ( (THD-V%,THD-I%, up to 31th harmonic for current and voltage separately) 3 Phase 4 wire Digital Power Analyzer with following Features complete all as specified and directed.
B). Meter Display Parameters: V, A, F, kW, KVA, kVAr, kWh, kVAh, kVArh, PF, Runhr, Onhr, Interupts,
Phase angle, THD, Neutral current, Max Demand (with RTC) K Factor
C). Meter Communication Enable: RS 485 Communication.
D). Alarm Contact Output & 4-20mA Analog output for PLC's.
E). Displays Maximum & Minimum Demand Values.
F). Meter can be site selected for parameters and values - A THD, V THD, VA, W, under PF, under/over (VLL, A, F) with programmable trip time (1 to 180 sec) to protect the equipments from electrical abnormalities.
G). Confirming IEC- 62053-24 | 22 | Each | 9,800 ₹2,15,600 Lowest | 13,000 ₹2,86,000 | 59,400 ₹13,06,800 | 36,000 ₹7,92,000 | 34,056 ₹7,49,232 |
| 2.00 | Supply,fixing,testing and commissioning of ACB, 4Pole of Microprocessor Based with breaking capacity of 50kA, Ics=100% Icu, Inbuilt or External Instantaneous Protection and Inbuilt Ground Fault Protection Individual Fault Indication LEDs incl Suitable size of CTs asper site requirement Suitable Size of ACB it must be minimum of 1.3 times of Tx. including Shunt Release system with suitable size of panel cabinet made of CRCA sheet of 2 mm thickness Loading Current where PTR 1.6 MVA (33/11KV) complete all as specified and directed. ACB Has Energy Metering and inbuilt RS485 Communication | 2 | Each | 3,39,500 ₹6,79,000 Lowest | 4,50,000 ₹9,00,000 | 3,82,800 ₹7,65,600 | 8,10,000 ₹16,20,000 | 4,62,132 ₹9,24,264 |
| 3.00Supply,fixing,testing and commissioning of MCCB, 4Pole of Microprocessor Based with breaking capacity of 50kA, Ics=100% Icu, Inbuilt or External Instantaneous Protection and Inbuilt Ground Fault Protection Individual Fault Indication LEDs incl Suitable size of CTs asper site requirement & Suitable Size of MCCB it must be minimum of 1.3 times of Tx. including Shunt Release system complete all as specified and directed. MCCB Has inbult RS485 Communication enabled. and inbuilt current metering display › Ics=100% Icu › Adjustable Overload Settings from 0.25 to 1 In (in steps of 0.01) › Adjustable Short Circuit Settings from 1.5 to 12 Ir (in steps of 0.1) › Adjustable Instantaneous Settings from 1.5 to 12 Ir (in steps of 0.1) › In-built Ground Fault Protection from 0.1 to 1 In (in steps of 0.05) › Adjustable Neutral Overload Protection from 50% to 160% of Ir › Local LCD Display Menu Navigation using Keypad › Modbus RTU Communication Capable › Switchable Thermal Memory › Provision for Release Testing › Variable trip class › Transparent sealable release cover › Compact size › Wide range of accessories Note :- Provn of suitable size of panel cabinet made of CRCA sheet of 3.15 mm thickness in case of non availibilty space for mounting arrangement of MCCB on existing Panel is deemed to be included in the quoted unit rate. | ||||||||
| 4.00 | All as per item No. 03 here-in-before but, 100 A ( Suitable for DTR 63 KVA (33/0.415 KV) | 1 | Each | 27,500 ₹27,500 | 23,000 ₹23,000 Lowest | 46,200 ₹46,200 | 45,000 ₹45,000 | 59,268 ₹59,268 |
| 5.00 | All as per item No. 03 here-in-before but, 200 A (Suitable for DTR 100 KVA (11/0.415KV) | 3 | Each | 32,500 ₹97,500 Lowest | 45,000 ₹1,35,000 | 46,200 ₹1,38,600 | 45,000 ₹1,35,000 | 69,960 ₹2,09,880 |
| 6.00 | All as per item No. 03 here-in-before but, 250 A ( Suitable for DTR 160 KVA (11/0.415KV) | 2 | Each | 35,500 ₹71,000 Lowest | 45,000 ₹90,000 | 46,200 ₹92,400 | 63,000 ₹1,26,000 | 69,960 ₹1,39,920 |
| 7.00 | All as per item No. 03 here-in-before but , 315 A (Suitable for DTR 200 KVA (11/0.415KV) | 3 | Each | 39,500 ₹1,18,500 Lowest | 46,000 ₹1,38,000 | 73,920 ₹2,21,760 | 63,000 ₹1,89,000 | 82,632 ₹2,47,896 |
| 8.00 | All as per item No. 03 here-in-before but , 500 A (Suitable for DTR 250 KVA (11/0.415 KV) | 10 | Each | 41,500 ₹4,15,000 Lowest | 56,000 ₹5,60,000 | 1,16,160 ₹11,61,600 | 72,000 ₹7,20,000 | 99,924 ₹9,99,240 |
| 9.00 | All as per item No. 03 here-in-before but , 630 A (Suitable for DTR 400 KVA (11/0.415 KV) | 1 | Each | 55,800 ₹55,800 Lowest | 58,000 ₹58,000 | 1,16,160 ₹1,16,160 | 72,000 ₹72,000 | 99,924 ₹99,924 |
| 10.00 | Supply,fixing,testing and commissioning of Energy Management System Software (SCADA) with Following Features:-
Data base Integration Software,Monitoring of all connected meters, Daily/ weekly / Monthly Report generation for analysis Graphical Analysis of all electrical parameters of each meter & also main Meter,Alarms -User Define alarms for Low PF/ Maximum Demand overshoot etc complete all as specified and directed.
Note :- OEM auth System Integretor shall ensure that the SCADA/EMS and RTU/Master Controll Unit should be same make asper mentioned in Tender documents. | 1 | Set | 6,00,000 ₹6,00,000 | 12,50,000 ₹12,50,000 | 6,13,800 ₹6,13,800 | 7,20,000 ₹7,20,000 | 5,21,400 ₹5,21,400 Lowest |
Tender Value
₹73.4 L
EMD Value
₹1.4 L
Closing Date
26 Mar 2026, 6:00 pmClosed
Col Pawan Kumar, CWE
Headquarters, Commander Works Engineer, Bhopal, Military Engineer Services, SI Line, Bhopal, Pin Code - 462001 (Madhya Pradesh)
AUGMENTATION OF EXTERNAL ELECT SUP INCL UPGRADATION OF EXISTING TRANSFORMER AT SI LINES UNDER GE BHOPAL
2025_MES_740870_3
84114/E8
Open Tender
Civil Works
Item Rate
180 days
Bhopal
AS PER NIT CONDITION
7 documents required · 7 mandatory
₹1,000
Yes
GE Bhopal
₹1.4 L
Yes
6 Jul 2026
16 Mar 2026
28 Mar 2026
16 Mar 2026
26 Mar 2026
21 Mar 2026
16 Mar 2026 - 21 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply,fixing,testing and commissioning of Digital Power Meters
A). All the electrical Parameters with Harmonic Measurement ( (THD-V%,THD-I%, up to 31th harmonic for current and voltage separately) 3 Phase 4 wire Digital Power Analyzer with following Features complete all as specified and directed.
B). Meter Display Parameters: V, A, F, kW, KVA, kVAr, kWh, kVAh, kVArh, PF, Runhr, Onhr, Interupts,
Phase angle, THD, Neutral current, Max Demand (with RTC) K Factor
C). Meter Communication Enable: RS 485 Communication.
D). Alarm Contact Output & 4-20mA Analog output for PLC's.
E). Displays Maximum & Minimum Demand Values.
F). Meter can be site selected for parameters and values - A THD, V THD, VA, W, under PF, under/over (VLL, A, F) with programmable trip time (1 to 180 sec) to protect the equipments from electrical abnormalities.
G). Confirming IEC- 62053-24 | 22 | Each | - | - |
| 2 | Supply,fixing,testing and commissioning of ACB, 4Pole of Microprocessor Based with breaking capacity of 50kA, Ics=100% Icu, Inbuilt or External Instantaneous Protection and Inbuilt Ground Fault Protection Individual Fault Indication LEDs incl Suitable size of CTs asper site requirement Suitable Size of ACB it must be minimum of 1.3 times of Tx. including Shunt Release system with suitable size of panel cabinet made of CRCA sheet of 2 mm thickness Loading Current where PTR 1.6 MVA (33/11KV) complete all as specified and directed. ACB Has Energy Metering and inbuilt RS485 Communication | 2 | Each | - | - |
| 3 | Supply,fixing,testing and commissioning of MCCB, 4Pole of Microprocessor Based with breaking capacity of 50kA, Ics=100% Icu, Inbuilt or External Instantaneous Protection and Inbuilt Ground Fault Protection Individual Fault Indication LEDs incl Suitable size of CTs asper site requirement & Suitable Size of MCCB it must be minimum of 1.3 times of Tx. including Shunt Release system complete all as specified and directed. MCCB Has inbult RS485 Communication enabled. and inbuilt current metering display › Ics=100% Icu
› Adjustable Overload Settings from 0.25 to 1 In (in steps of 0.01)
› Adjustable Short Circuit Settings from 1.5 to 12 Ir (in steps of 0.1)
› Adjustable Instantaneous Settings from 1.5 to 12 Ir (in steps of 0.1)
› In-built Ground Fault Protection from 0.1 to 1 In (in steps of 0.05)
› Adjustable Neutral Overload Protection from 50% to 160% of Ir
› Local LCD Display Menu Navigation using Keypad
› Modbus RTU Communication Capable
› Switchable Thermal Memory
› Provision for Release Testing
› Variable trip class
› Transparent sealable release cover
› Compact size
› Wide range of accessories
Note :- Provn of suitable size of panel cabinet made of CRCA sheet of 3.15 mm thickness in case of non availibilty space for mounting arrangement of MCCB on existing Panel is deemed to be included in the quoted unit rate. | - | - | - | - |
| 4 | All as per item No. 03 here-in-before but, 100 A ( Suitable for DTR 63 KVA (33/0.415 KV) | 1 | Each | - | - |
| 5 | All as per item No. 03 here-in-before but, 200 A (Suitable for DTR 100 KVA (11/0.415KV) | 3 | Each | - | - |
| 6 | All as per item No. 03 here-in-before but, 250 A ( Suitable for DTR 160 KVA (11/0.415KV) | 2 | Each | - | - |
| 7 | All as per item No. 03 here-in-before but , 315 A (Suitable for DTR 200 KVA (11/0.415KV) | 3 | Each | - | - |
| 8 | All as per item No. 03 here-in-before but , 500 A (Suitable for DTR 250 KVA (11/0.415 KV) | 10 | Each | - | - |
| 9 | All as per item No. 03 here-in-before but , 630 A (Suitable for DTR 400 KVA (11/0.415 KV) | 1 | Each | - | - |
| 10 | Supply,fixing,testing and commissioning of Energy Management System Software (SCADA) with Following Features:-
Data base Integration Software,Monitoring of all connected meters, Daily/ weekly / Monthly Report generation for analysis Graphical Analysis of all electrical parameters of each meter & also main Meter,Alarms -User Define alarms for Low PF/ Maximum Demand overshoot etc complete all as specified and directed.
Note :- OEM auth System Integretor shall ensure that the SCADA/EMS and RTU/Master Controll Unit should be same make asper mentioned in Tender documents. | 1 | Set | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
84114TenderDocuments.pdf
Tender Documents • 1.28 MB
BOQ_847313.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .