Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 LAccepted-AOC | L1 | Accepted-AOC Work Order Issued | |
| 2 | L2₹9.3 L+₹51,853 (5.89%)Rejected-Finance | L2 | Rejected-Finance Reject | |
| 3 | L3₹9.4 L+₹55,945 (6.35%)Rejected-Finance P W D YANAM | L3 | Rejected-Finance Reject | |
| 4 | L4₹9.6 L+₹76,194 (8.65%)Rejected-Finance YANAM 533464 | YANAM | YANAM | PUDUCHERRY | 533464 | L4 | Rejected-Finance Reject |
Tender Value
₹10.0 L
EMD Value
₹19,961
Closing Date
18 Jan 2020, 3:30 pmClosed
EE PWD Yanam
Chinta Street, Yanam
Renovation of Old Veterinary Sub-Centre to Temporary Kitchen at Dariyalathippa, Yanam.
2020_PWDC2_5598_1
116/EEY/2019-20
Open Tender
Civil Works
Works
60 days
Yanam
Please refer Tender documents.
2 documents required · 2 mandatory
₹525
EE PWD Yanam
₹19,961
18 Feb 2020
10 Jan 2020
20 Jan 2020
10 Jan 2020
18 Jan 2020
10 Jan 2020
Amount
12.20 Providing and laying pressed clay tiles (as per approved pattern 18mm nominal thickness and of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% intergral water proofing compound laid over a bed of 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete.
15.3 Demolishing R.C.C. work, including stacking of steel bars and disposal of unserviceable material within 50 metres lead.
15.23.1 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50m lead - For thickness of tiles above 10mm and upto 25mm.
15.7.4 Demolishing brick work, manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead - In cement mortar.
2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms , lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed , within a lead of 50m -All kinds of soil.
5.22.6 Reinforcement for R.C.C work including straightening , cutting , bending , placing in position and binding all complete - Thermo - Mechanically treated bars (TISCON / VIZAG / IISCO /SAIL / JSW) including placing the M30 grade Athees make cover block @ 60cm centre to centre.
6.1.2 Brick work with FPS bricks of class designation 35 in foundation and plinth in cement mortar 1:6 (1 cement: 6 coarse sand).
6.4.2 Brick work with FPS bricks of class designation 35 in superstructure above plinth level upto floor V level in all shapes and sizes in cement mortar 1:6 (1 cement : 6 coarse sand).
4.1.3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering.- All work upto plinth level -1:2:4 (1 cement:2coarse sand : 4 graded stone aggregate 20mm nominal size)
5.1.2 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of entering,shuttering, finishing and reinforcement -All work upto plinth level : 1:1.5:3 (1 cement : 1 .5 coarse sand : 3 graded stone aggregate 20mm nominal size).
5.2.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters , buttresses, plinth and string courses , fillets, columns , pillars, piers, abutments, posts and struts etc.upto floor five level excluding cost of centering, shuttering, finishing and reinforcement:1:1.5:3 (1 cement : 1.5coarse sand : 3 graded stone aggregate 20mm nominal size).
5.3.1 Reinforced cement concrete work in beams , suspended floors, roofs having slope upto 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement :1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).
5.9.2 Centring and shuttering including strutting, propping etc. and removal of form for: Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.- Using steel sheet with M.S.frames.
5.9.3 Centring and shuttering including strutting, propping etc. and removal of form for: suspended floors, roofs, landings, balconies and access platform - Using steel sheet with M.S. frames.
5.9.5 Centring and shuttering including strutting, propping etc. and removal of form for: lintels, beams, plinth beams, girders, bressumers and cantilevers.- Using steel sheet with M.S. frames.
5.9.6 Centring and shuttering including strutting, propping etc. and removal of form for columns, pillars, piers,abutments,posts and struts.- Using steel sheet with M.S.frames.
2.27 Supplying and filling in plinth with sand under floors including, watering, ramming consolidating and dressing complete.
4.1.10 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering.- All work upto plinth level -1:5:10 (1 cement:5coarse sand : 10 graded stone aggregate 40mm nominal size).
11.3.1 Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mm nominal size stone aggregate.
11.26.1 Kota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand 25mm thick.
13.1.2 12mm cement plaster of mix: Cement 1:6 (1 cement : 6 fine sand) mortar.
13.16.1 6mm cement plaster of mix 1:3 (1 cement : 3 fine sand).
10.27 Supplying and fixing of steel grill work of m.s. angles, flats, squares and pipes including cost of welding charges, fixing in position in masonry walls with cement concrete 1:2:4 (1 cement : 2 course sand : 4 graded stone aggregate 12.5mm nominal size) including one coat of priming coat etc. complete.
12.70 Providing and fixing colour coated galvalume sheet of 550 M.P.A yield of AZ 150 strength formed as per patterned steel rib profile with the depth of 31mm pitch of 250mm and overall width of 1060mm and thickness 0.5mm with required J or C hook bolts and nets 8mm dia G.S paint and working etc., complete excluding the cost of purlin , rafter and truss etc.,
10.2 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI: 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet outlet and overflow pipes but with out fittings and the base support for tank.
13.48.1 Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using primer as permanufacturers specifications-Two or more coats applied @ 1.25 ltr /10 sqm over and including one coat of special primer applied @ 0.75 ltr / 10 sqm.
14.66.1 Finishing walls with Acrylic Smooth exterior paint of required shade - Old work (Two or more coats applied @ 1.67 lts/10 sqm.) on existing cement paint surface.
18.7.2 Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fitting with one step CPVC solvent cement and testing of joints complete (Internal work exposed on wall) - 20mm nominal outer dia pipes.
18.51.1 Providing and fixing CP brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms - 15mm nominal bore.
13.61.1 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade - Two or more coats on new work.
14.54.1 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade - One or more coats on old work.
20.2.1 Boring, providing and installing bored cast-in-situ reinforced cement concrete pile of specified diameter and length below the pile cap M35 in cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with, bentonite solutions and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc., all complete, including removal of excavated earth with all lifts and leads (length of pile for payment shall be measured upto bottom of pile cap). 300mm dia piles.
Basic Code No.3130 Supply and fixing 375mm 1400 rpm heavy duty exhaust fan. Make: Almonard/ Orient/Usha as directed by the Engineer in-charge.
Basic Code No.3052 Supply and fixing 3052 2x 40W box type twin tube light fitting with copper choke & starter without tube. Make: Philips/Bajaj as directed by the Engineer in-charge.
Basic Code No.3115 Supply and fixing 15W / 20W CFL lamp for pendent holder. Make: Philips as directed by the Engineer in-charge.
Basic Code No.3112 Supply and fixing 40W tube light. Make: Philips as directed by the Engineer in-charge.
Basic Code No.1401 Supply and fixing Ceiling rose, 3 plate,5 amps bakelite. Make: Kundan/ Anchor / Vinayas as directed by the Engineer in-charge.
1.7.2.2 Supplying and fixing jumbo type Batten/Angle Holder including connections etc. as required .Make: Kundan/ Anchor/Vinay:-
1.7.3.15 Supplying and fixing of Stepped type modular Fan Regulator on the existing modular plate and switch box including connections but excluding modular plate as required.Make: Legrand- Mosaic/ ABB:-
1.7.3.1 Supplying and fixing of S.P. 5/6 amps, one way modular switch on the existing modular plate and switch box including connections but excluding modular plate etc.as required. Make: Legrand -Mosaic/ ABB:-
1.7.3.6 Supplying and fixing of 3 pin 15/16 amps modular socket outlet, on the existing modular plate and switch box including connections but excluding modular plate etc.as required. Make: Legrand-Mosaic/ABB:-
1.7.3.4 Supplying and fixing of S.P.15/16 amps, one way modular switch on the existing modular plate and switch box including connections but excluding modular plate etc.as required. Make: Legrand - Mosaic/ ABB:-
1.4.7A Supplying and fixing of modular GI box for 12 module including cutting the wall and making good the same as required - Make: Crabtree /ABB.
1.7.4.7 Supplying and fixing of modular base and cover plate for 12 module on the existing modular metal boxes etc. as required.Make:Legrand- Mosaic/ MK/ Siemens/Crabtree/ABB.
1.4.6A Supplying and fixing of modular GI box for 8 module including cutting the wall and making good the same as required - Make: Crabtree/ ABB.
1.7.4.6 Supplying and fixing of modular base and cover plate for 8 module on the existing modular metal boxes etc. as required. Make:Legrand/ Mosaic/ MK/ Siemens/Crabtree/ ABB.
1.7.3.3 Supplying and fixing of 3 pin 5/6 amps modular socket outlet, on the existing modular plate and switch box including connections but excluding modular plate etc.as required. Make: Legrand-Mosaic/ABB:-
1.4.5 Supplying and fixing of modular GI box for 6 module including cutting the wall and making good the same as required - Make: Legrand- Mosaic / Siemens.
1.7.4.5 Supplying and fixing of modular base and cover plate for 6 module on the existing modular metal boxes etc. as required. Make: Legrand- Mosaic/MK/ Siemens/ Crabtree/ ABB.
1.4.2 Supplying and fixing of modular GI box for 2 module including cutting the wall and making good the same as required - Make:Legrand-Mosaic/ MK/ Siemens/ Crabtree /ABB.
1.7.4.2 Supplying and fixing of modular base and cover plate for 2 module on the existing modular metal boxes etc. as required. Make:Legrand-Mosaic/ MK/ Siemens/Crabtree/ ABB.
1.1.1.2 Supplying and fixing of following size of PVC conduit along with the accessories in surface/recess Conduit including cutting the wall and making good the same in case of recessed conduit as required. Make: Avonplast /Vijaya:- 25mm dia.
1.1.3.2.3 Supplying and fixing of following size of PVC junction box in required position along the line of PVC conduit as required. Make: Avonplast /Vijaya:-25mm Junction Box three way.
1.5.1 Supplying and drawing of 1.5 sqmm. FR PVC insulated, copper conductor, single core cable in the existing surface/ recessed, PVC/ steel conduit/ PVC casing and capping as required. Make: Finolex/Polycab:-
1.5.2 Supplying and drawing of 2.5 sqmm. FR PVC insulated, copper conductor, single core cable in the existing surface/ recessed, PVC/steel conduit/PVC casing and capping as required.Make: Finolex/Polycab:-
KSS RAMACHANDRUDU
Kondamuri Sathibabu
P Venkata Ramana Murthy
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .