Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹119.5 CrAccepted-AOC | ₹119.5 Cr | 1 | Accepted-AOC Accept |
| 2 | 2₹120.0 CrRejected-Finance OFFICE NO 201 DECENT HOMES OPP URBO HOTEL NEAR GANRAJ CHOWK BANER PUNE 411045 | PUNE | PUNE | MAHARASHTRA | 411045 | ₹120.0 Cr | 2 | Rejected-Finance Reject |
Tender Value
₹113.9 Cr
EMD Value
₹57.0 L
Closing Date
29 Aug 2024, 3:00 pmClosed
Executive Engineer
Office of the Executive Engineer, Presidency Division, P.W.D., 2nd floor, Bandhakam Bhavan, 25, Marzban Road, Fort, Mumbai- 400 001
Construction of Maharashtra Bhavan (Bhakt Niwas) at U.P. Government Awas Evam Vikash Parishad (Greenfield Township) at Plot No. 8A/MISB-02 at Sahanewajpur Maza, Ayodhya, Uttar Pradesh, India. (Including Civil and Electrical works)
2024_PWR_1066993_1
EE/PD/TC/Notice No-6_B-2_Tender
Open Tender
Civil Works
1080 days
Mumbai
Please refer Tender documents
3 documents required · 3 mandatory
₹5,900
₹57.0 L
Yes
Chief Engineer Mumbai
28 Oct 2024
8 Aug 2024
30 Aug 2024
8 Aug 2024
29 Aug 2024
8 Aug 2024
16 Aug 2024
Amount
Providing and Casting RCC bored cast in-situ Vertical as per IS 2911 (Part 1, Section 2) by boring through all kinds of soils/ Sand /Rock by rotary hydraulic rigs using temporary casing up to stable strata / bentonite mud circulation as specified, from tip to cut-off elevation of piles. Reinforced Cement Concrete work of filling the bore (after placement of reinforcement cage as per drawing) with M35 grade Ready Mix Concrete using 43 Grade Ordinary Portland Cement confirming to IS : 8112, of approved make and brand with minimum cement content of 400 kg/m3 and with water -cement ratio, including the water contained in aggregates (10mm to max 20mm size), not exceeding 0.45, with approved plasticizer as specified, including placing of concrete from tip to minimum of 600mm above the specified cutoff level, breaking pile head to cutoff level and exposing pile reinforcement for embedment in pile cap, Disposing & levelling of bored/excavated material suitably at locations approved by the local authorities including all lead and lifts, all complete for piles having diameter of (Pile will be measured for payment for length between pile tip to cut-off level along the pile axis. Reinforcement shall be paid separately)Note : Cost of temporary casing shall be incurred by the Contractor. Providing and maintaining Barricading on the site 5 m high by using MS Pipes or angle iron frame work of verticals at 3 m c/c and horizontals at 0.90 m c/c, Galvalume sheets, Struts, MS Clamps, etc. The verticals shall be embedded/ fixed to concrete pedestals below ground. The rate to include fabricating, cutting and fixing in position MS frame work, painting the same with two coats of approved antirust paint, etc complete. Contractor to get structural design approvedby the Engineer. Contractor shall remove and take away thebarricading at his own cost on completion of the works for 800 mm
For 600 mm
Providing and Casting RCC bored cast in-situ Vertical as per IS 2911 (Part 1, Section 2) by boring through all kinds of soils/ Sand /Rock by rotary hydraulic rigs using temporary casing up to stable strata / bentonite mud circulation as specified, from tip to cut-off elevation of piles. Reinforced Cement Concrete work of filling the bore (after placement of reinforcement cage as per drawing) with M30 grade Ready Mix Concrete using 43 Grade Ordinary Portland Cement confirming to IS : 8112, of approved make and brand with minimum cement content of 400 kg/m3 and with water -cement ratio, including the water contained in aggregates (10mm to max 20mm size), not exceeding 0.45, with approved plasticizer as specified, including placing of concrete from tip to minimum of 600mm above the specified cutoff level, breaking pile head to cutoff level and exposing pile reinforcement for embedment in pile cap, Disposing & levelling of bored/excavated material suitably at locations approved by the local authorities including all lead and lifts, all complete for piles having diameter of (Pile will be measured for payment for length between pile tip to cut-off level along the pile axis. Reinforcement shall be paid separately)Note : Cost of temporary casing shall be incurred by the Contractor. for 600 mm
Carrying out load test for 1.5 times the proposed safe working load on the pile in driven position above 750 mm and upto 825 mm diameter including construction of test cap, use of accessories and instruments including providing graphs as per I.S. code or Std.Specifications and dismantling the test cap after testing and cleaning the site complete
Integrity testing of Pile using Low Strain/ Sonic Integrity Test/ Sonic Echo Test method in accordance with IS 14893 including surface preparation of pile top by removing soil, mud, dust & chipping lean concrete lumps etc. and use of computerised equipment and high skill trained personal for conducting the test & submission of results, all complete as per direction of Engineer-in-charge.
Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. (Bd.C.2 Page Number 275)
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete with all lead and lift uppto 1.50 metre.
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete with all lead and lift beyond 1.5 mtr and upt 3.00 mtr.
Excavtion In soil (Lift beyond 3.0 mtr.)
Providing preconstructional antitermite treatment as per S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyri fos per square meter surface area covering 10 years guarantee on bond paper. Spec. As directed by Engineer in charge.
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-I) to the soil along the external face of building by punching holes of 1.2 of 1.5 C.M. diametre about 30 -60 cm deep at 15 cm c/c as close to the wall as possible and to inject 0.5 percent of aldrin or clorophyrifos at the rate of 7.5 litres per hole and sealing the same with proper filling and covering 10 years guarantee on bond paper. As directed by Engineer in charge.
Providing and laying Cast in situ/Ready Mix cement concrete in M20 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) (Bd.E.4 Page Number 289 and B- 7, Page Number38) Upto 1st Floor
Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. Upto 1st Floor
Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimeter thick Cement mortar 1:3 with conceal, secrete (RMW), Algae proof or other alike waterproofing liquids, raking of joints upto 35 mm depth, filling the joints with 6 mm size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete ) [Bd.J.2 Page No. 355]
Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Upto 1st
Above 1st to 12th floor and terrace
Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 mm between rough shahabad and R.C.C. walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 mm and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete) [Bd.J.2 Page No. 355]
Providing and fixing in position HCRM/CRS (Corrosion Resistant Steel) bar reinforcement of various diameters for R.C.C. pilecaps, footings, foundations, slabs, beams, columns, canopies, staircase, newels,chajjas, lintels pardis, copings, fins,arches etc. as per detailed designs,drawings and schedules including cutting, bending, hooking the bars,binding with wires or tack welding and supporting as required complete. Upto 1st Floor
Above 1st to 12th floor and terrace
Providing and laying Cast in situ/Ready Mix cement concrete M-35 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) [Bd.F.11 Page No. 304 and B.7, Page No. 38]
Above 1st non structural wall
Providing and laying Cast in situ/Ready Mix cement concrete M-35 of trap / granite/quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Upto 1st Floor
Above 1st to 12th floor and terrace
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite/quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Upto 1st Floor
Above 1st to 12th floor and terrace
Providing and laying Cast in situ/Ready Mix cement concrete M-35 of trap / granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Upto 1st Floor
Above 1st to 12th floor and terrace
Providing and laying Cast in situ/Ready Mix cement concrete M-35 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Upto 1st Floor
Above 1st to 12th floor and terrace
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Upto 1st Floor
Above 1st to 12th floor and terrace
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Upto 1st Floor
Above 1st to 12th floor and terrace
Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap / quartzite /granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement, including precast concrete cover blocks of same or Higher Grade. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) [Bd. F. 13 Page No. 305 /I.S. 456 (2000)] Upto 1st Floor
Above 1st to 12th floor and terrace
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C.coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Upto 1st Floor
Terrace
Providing & Laying Plum concrete consisting of 80% P.C.C. mix (1:3:6) and 20% Rubble stone of maximum size of 150 mm laid in layers with ramming consolidating,watering including dewatering cost,seigniorage & conveyance of all materials,labour charges,machine mixing,finishing the surface etc. complete. Upto 1st Floor
Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) Upto 1st Floor
Above 1st to 12th floor and terrace
Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. As directed by Engineer in Charge Upto 1st Floor
Above 1st to 12th floor and terrace
Providing internal / external 12 mm thick Ready Mix plaster confirming to IS:4031 (Part-4) 1988 and IS383 -1970 in a single coat using Cement mortar of proportion 1:4 containing special type of polymer additives about 0.4%, to all type of surfaces in all positions including scaffolding and curing complete. As directed by Engineer Incharge Upto 1st Floor
Above 1st to 12th floor and terrace
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc. complete. Upto 1st Floor
Above 1st to 12th floor and terrace
Providing and fixing double scaffolding system (cuplocktype) on the exterior side of building/structure, including additional rows of scaffolding in stepped manner as per requirement of site,mad with 40mm dia M.S.tube,placed 1.5 metre centre to centre,horizontal&vertical tube sjoint with cup& lock system with M.S.Tubes,M.S.tube challis,M.S.clamps and staircase system in the scaffolding for working platform etc.and maintaining it in a serviceable condition for execution of work of cleaning and/or pointing and/ or applying chemical and removing it thereafter.The scaffolding system shall be stiffened with bracings, runners,connecting with the building etc,wherever required,if feasible,for inspection of work at required locations with essential safety features for the work men etc.,complete as per directions and approval of Engineer-in-charge.Note:-(1)The elevational area of the scaffolding shall be measured for payment purpose.(2)The payment will be made once only for execution of all items for such works. Upto 1st Floor
Above 1st to 12th floor and terrace
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. Upto 1st Floor
Above 1st to 12th floor and terrace
Providing and applying three coats of water proof cement paint of approved manufacture and of approved colour to new plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc. complete. (Bd.O.8/Page Number406) Upto 1st Floor
Above 1st to 12th floor and terrace
Providing and fixing false ceiling with eco-friendly light weight calcium silicate tiles of Spintone/cosmos surface textured "Aerolite " make or equivalent of size 595 x 595mm having 15 mm thick densified microlook edge and 100% humidity resistence, incombustible as per BS 476 Part IV and thermal conductivity 0.043 w/m° and NRC 0.50 placed in true horizontal level suspended grid of size 600x600 mm made from hot dipped GI steel sections on Sillhoutte profile, rotary stitched double webbed white with 6mm reveal profile (white/black), where in main T runner of size 24 mm x 38mm and 0.33 mm thick @ 1200mm center to center and cross T of size 24mm X 28 mm and 0.33 mm thick, 1200 mm long spaced between main tee at 600 mm centre to centre and secondary cross T of Size 24mm X 28 mm x 0.33 thick of length 600 mm to be inter locked at middle of the first cross T in each panel to form grids of 600 mm x 600 mm and resting on periphery wall profile wall section 24 mm x 24mm x 0.40 thickness and laying false ceiling for services like diffusers grills including cutting, making opening for light fitting, fixtures, smoke detectors etc. wherever required, main tee runner to be suspended form ceiling using G.I. soffit cleats of size 25 x 35 x 1.6 mm of required length fixed to the ceiling with12.5mm dia and 50 mm long dash fastener, 4 mm dia G.l adjustable rods with good quality G.I level adjustment clips of 85 X 30 X 0.8mm spaced at 1200 mm center to center along main tee all complete at all heights as per specifications, drawings and as per direction of Engineer - in - Charge. Above 1st to 12th floor and terrace
Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vIrgin concrete slab with waterproofing compound @ 1kg/per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 kg/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 kg/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete. As directed by Engineer in charge Upto 1st Floor
Above 1st to 12th floor and terrace
Providing and applying two coats of protective membrane over the cured concrete surface like R.C.C. footings, columns, plinth beams etc. which will be submerged under soil so as to protect the same. Apply two pack coal tar epoxy system of Sunepoxy Coaltar of approved make & approved by Engineer in charge, having solid content ranges from 80-100%, Tack free time 4-6 hrs. Recoat after 16-24 hrs. Mix Part A and Part B of Sunepoxy Coaltar of approved make & approved by Engineer in charge in 1:1 ratio with slow speed stirrer and apply the same on a clean R.C.C. surface by brush. Allow to set for 8-10 hours and apply the second coat. The rate to include for application at all levels to various RCC elements to the satisfaction of the EIC etc. complete. Upto 1st Floor
Providing waterproof plaster in W.C. and bath 12 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 Kilogram. per bag of cement of approved make and manufacturer and curing etc. complete. (Excluding Tiles) (As directed by Engineer in Charge) Upto 1st Floor
Above 1st to 12th floor and terrace
Providing and laying waterproofing tratment of 112 mm average thickness consisting of 12 mm thick layer in cement mortar 1 : 4 with water proofing compound at the rate of 1 kg per bag of cement as base, constructing and laying brick bat coba in cement mortar 1:5 with waterproofing compound at the rate of 1 kg per bag of cement and having average thickness of 80 mm and finishing with 2 mm thick cement plaster layer in cement mortar 1:4, aterproofing compound at the rate of 1 kg per bag of cement bag, laying in required position flooring of broken China mosaic (broken pieces of China chips) of approved colour and pattern including neat cement float, giving proper slopes, compaction, curing, finishing preparing bell mouth etc. including all lead , lifts and laid to proper slope to drain off water entirely including watta, Bell head or Champhered portion at the junction of parapet and work upto a height of 300 mm or as directed and covering the whole treatmnet with yten years guarantee, on requisite stamp paper etc. complete (Spec : As directed by Engineer in charge) Entrance canopy
Terrace Water Proofing
Providing and applying a base coat comprising of 1 KilogramPolydee-MC and 1Kilogram fresh cement after wetting the surface followed by drying the surface for 2 days, apply primer coat of TP-40 and after drying, applying Polydee-11 two component (mixing ratio 2A :1 B) ) Antibacterial food grade coating inside drinking water tank in two coats with time interval of minimum 8 hrs. covering 7 years guarantee on Court Fee Stamp Paper of Rs. 100/- etc. complete. Above 1st to 12th floor and terrace
Providing and laying machine cut and mirror polished approved coloured ITALIAN MARBLE SLAB approved size, 20 mm +/- 2 mm thick of approved quality with approved qality, Italian marble inlays for flooring in required pattern on a bed of 1:4 cement mortar 25- 30 mm average thickness including neat cement float, filling joints with neat coloured cement slurry, curing, polishing and cleaning complete. ( Basic rate of ITALIAN marble Rs. 10,000/- per Sq.M) of Beige Botticino, Crema Marfil, Grey Fiasco, Spanish Grey, Light Emperador, Armani Grey Upto 1st Floor
Above 1st to 12th floor and terrace
Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. Upto 1st Floor
Above 1st to 12th floor and terrace
Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS.15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, fillingjoints, curing and clearing etc. complete. Upto 1st Floor
Above 1st to 12th floor and terrace
Providing and laying vitrified rustic matt stone finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. [Bd.M.12 Page No. 385] Upto 1st Floor
Above 1st to 12th floor and terrace
Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. [Bd.M.22 Page No. 390] Upto 1st Floor
Above 1st to 12th floor and terrace
Providing 25 mm to 30 mm thick partition of polished black kadappa stone slab ofapproved quality including giving required size and shape etc. Fixing in cement mortar1:3 curing and cement etc. complete. b) Both side polish Upto 1st Floor
Above 1st to 12th floor and terrace
Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete Upto 1st Floor
Above 1st to 12th floor and terrace
Providing and laying telephone black / Amba White / Cadbury brown / Rubyred / Ocean Brown granite stone of 18 to 20 mm thick for door frame / dado / window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing / moulding the sharp edges where ever necessary, curing, etc. complete. As directed by Engineer-In- Charge Upto 1st Floor
Above 1st to 12th floor and terrace
Providing and fixing machine cut and mirror polished approved coloured ITALIAN MARBLE CLADDING with inlays of approved size,20mm +2mm thk. Of approved quality for required patternon a bed of 1:4 CM 25mm average thickness including neat cement float,filling joints with neat coloured pigment, curing, polishing and cleaning etc.complete. (Basic rate of ITALIAN marble Rs.10,000/-per Sq.M) of Beige Botticino, Crema Marfil, Grey Fiasco, Spanish Grey, Light Emperador, Armani Grey Upto 1st Floor
Providing and fixing oval type under counter wash hand basin of 16 inch x 22 inch size and of special colour shade having telephonic black / coloured granite of 180 mm thick stone black kadappa framework including chromium plated coupling bottle - Trap using CERA company or equivalent oval typa wash basin model no 3448 as per detailed drawing or as directed by engg incharge etc complete. (Counter size 1.20 m x 0.60 m ) Upto 1st Floor
Above 1st to 12th floor and terrace
Fire Door 55 mm 2HR FRL (120/120) 3 Criteria-INTEGRITY/ INSULATION/ STABILITY WOODEN DOOR - Fire Door Tested in accordance to IS: 3614 Part 2. Providing of 120 min Fire rated doors system duly tested for 3 criteria - Integrity, Insulation and Stability Criteria as per the IS: 3614 Part 2 and BS: 476 part 22 at National Test House, Govt of India laborator and/or with Central Building Research Institute, Govt of India undertaking with standard heating conditions as specified in IS:3614 Part II 1992 and BS: 476 part 20 & 22 1987 to achieve the required integrity, insulation and stability (i.e. to restrict the heat radiation, temperature rise on the non fire side to the maximum of 140° C above the ambient temperature on the exposed surface of the shutter. The fire doors are tested with NCBN technology ("Non Combustible by Nature"). a) Door Frame: Supplying & Fixing frames for Fire resistant door shutters 1st class Malaysian Hardwood Frame densified (810 Kilogram/cum) and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 psi pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 of section 120 X 70 mm spray quoted with 2 coats of intumescent paint of minimum 200 micron, with single row of Brush- Type ASTROFLAME intumescent strip of size 10mm x 4mm affixed in the slit of the Frame for fire and smoke sealing, etc. complete. Upto 1st Floor
Above 1st Floor to 5th Floor and Terrace Floor
b)Shutter : Supplying & Fixing of 55mm thick asbestos free criteria checked - fire, heat and smoke resistant composite Fire check Door Shutter complying with with fire performance - FD 120 as per IS:3614 (part - II) comprising of 2x8mm Calcium Silicate boards over Chemically treated (with Fire retardant chemicals in vaccum pressure impregnation vessels under 160 psi pressure as per IS:401 and kiln seasoned to moisture below 15% as per IS:1141) internal timber (Malaysian Hard Wood, densified to 810 Kilogram/cum) frame work of 100x32 mm with 32mm thick infill of ceramic fiber (density 128 Kilogram/cum), vermaculite mix faced with 3mm Fire retardant High Density fibre board, internally lipped with hardwood beading and pasted in Hydraulic Press under 25 MPa, spray quoted with 2 coats of in-tumescent paint of minimum 300 micron, and with single row of Brush- Type intumescent strip of size 10mmx4mm affixed on periphery for fire and smoke sealing in the slit on all edges of shutter except bottom, without any external lipping. Upto 1st Floor
Above 1st to 12th floor and terrace
c) Vision Panel:2 HR rated E Class clear high stress fire rated glass is pre fabricated strategically inside the shutter structure with 10 mm inside the shutter on all sides with U- glazing. An additional insulated powdercoated 'Z' channel of 16 swg MS sheet to be fixed for reinforcement of the joints.
Above 1st to 12th floor and terrace
Panic Bar: (For 2 Hr fire Rated single Panic bar)Supplying, fitting & fixing Surface mounted Crash Bar/ panic Bar of touch pad style ,made of heavy duty cast iron/ steel body & latches with SS ,BHMA certified & conforming to ANSI A 156.3 for grade-1 ( 3 hours fire rated ) and suitable for surface mounting to wooden/hollow metal/ Al framed door,with maximum operating force 8Kilogram for unlocking easily & outwardly during emergency,complete in all respect as per direction & satisfaction of Engineer-in charge including all taxes & incidental charges. (Note: To be installed at "FIRE EXIT"only under location specific instruction of Eingineer-in -Charge.) Upto 1st Floor
Above 1st to 12th floor and terrace
Door Closure: (For 2 Hr fire Rated EN-3 Door Closure)Supplying, fitting & fixing Surface mounted overhead Door Closer for 2 hour fire rated doors of different size (e.g size -EN-3 for leaf width upto 900mm) CE certified, marked & conforming to EN - 1154 of approved quality (Internationally reputed brand like Dorma, Geze, Hafele, Assabloy & Magnum etc.) fitted and fixed Complete as per direction & satisfaction of Engineer -in Charge including all taxes & incidental charges. Upto 1st Floor
Above 1st to 12th floor and terrace
12"SS Handle: (For 2 Hr fire Rated 12"SS Handle)Supplying, fitting & fixing Stainless Steel 'D' or 'H' type of size 300 mm x 19 mm tubular Handle with Grade 304, CE certified, marked & conforming to EN - 1154 of approved quality (Internationally reputed brand like Dorma, Geze, Hafele, Assabloy & Magnum etc.)as per direction of Eingineer -in Charge fitted and fixed complete including all taxes & incidental charges. Upto 1st Floor
Above 1st to 12th floor and terrace
Solid Core Flush door Single leafProviding and fixing factory made solid core flush door in single leaf 35 mm thick, decorative types, of exterior grade, as per detailed drawings, conforming to I.S.:2202 - 1962 (Revised) with approved face veneers on both faces with/without glazing and venetians in the positions shown on the drawings or as directed, all necessary beads, moulding and lipping, holdfasts, mat finish stainless steel fixtures fastenings , finishing with french-polish/ waxing complete. (without door frame).(Sample to be got approved from Ex.Engineer before use) Commercial Hard Wood shutter Upto 1st Floor
Above 1st to 12th floor and terrace
Providing and fixing collapsible steel gate in one / two leaves with hot rolled vertical channels of 18 x 9 x 3 mm minimum size, crossings of M.S. flats of size 18 x 5 mm T or E section for runner of minimum 40 x 6 mm size for flange, M.S. flat for top runner of minimum size 40 x 12 mm with roller wheels confirming to grade F.G. 150 fitted with snap headed rivets of minimum size 6 mm max. spacing of vertical channels be 100 mm enclosed gate position and clear space of 150 mm between two sets of crossings with hold fasts, stoppers, spaces, handles, locking arrangement and one coat of red lead primer and oil painting etc. complete. (I.S. 105211983). Upto 1st Floor
Above 1st to 12th floor and terrace
Providing and fixing fiber glass reinforced polyster door shutter 30 mm thick as per IS14856 (2000) (Reaffirmed 2006) without ventilator including chromium platedfixtures and fastening with chromium plated handles on both sides, etccomplete Upto 1st Floor
Above 1st to 12th floor and terrace
Providing and fixing in position powder coated aluminium louvered windows / ventilatorof various sizes with powder coating as per detailed drawing and specificationsincluding aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheetglass louvers, of approved quality etc. complete. Upto 1st Floor
Above 1st to 12th floor and terrace
Invisible Grills - Providing & Fixing invisible grills with alluminium track uses 316 marine grade stainless steel for the cables manufactured with 7 x 7 nano technology with 0.3 mm nylon coating. SpecsLoad Capacity - 250 Kgs / Plus Space - 1.5 inch No hot work/ No Welding Upto 1st Floor
Above 1st to 12th floor and terrace
Providing and fixing of factory made uPVC Sliding window & door (White Colour) complete, comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (+-0.2 mm), duly reinforced with G.I. section 1.5 mm, wherever required. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter 1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C 3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m2 4 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm2 5 Mean Breaking Stress for welded corner (a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2 (b) For the compression bending test Shall not be < 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 % 7 Surface Spread of flame BS : 476 - Part 7 Classification 1 8 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be < 35 MPa 10 Shear Modulus ASTM D 732 Shall not be < 220 MPa 11 Tensile Strength EN ISO 527 Shall not be < 30 MPa All corners of frame and sash will be fusion welded. After placing 5 mm Float Annealed glass in the sash, uPVC glazing bead, interlock, EPDM / TPE gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window / Door will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use. Upto 1st Floor ( 2 Track 2 / 4 Sash (Big Series) window frame of size 67 x 54 mm & Sash of size 64 x 47mm)
Above 1st Floor to 15th Floor and Terrace Floor ( 2 Track 2 / 4 Sash (Big Series) window frame of size 67 x 54 mm & Sash of size 64 x 47mm)
Providing & fixing S.S. pipe hand rail along the wall in staircase orramps or passages consisting of 50 mm dia. 18 gauge 304 grade stainless steel pipe. Supported with 25 mm 18 gauge S.S. pipe(304grade) brackets & 5mm thick tapered edge coller base plate fixedto wall with SS screws at approx. 600 mm center to center fixedhorizontally or in inclined position at required height including grindingthe welded joints, buffing,protecting the railing members by means of wrappers during construction etc. complete as per detailed drawing as directed by the Engineer in charge. Upto 1st Floor
Above 1st to 12th floor and terrace
Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter and 1.5mm thick at top,40mm diameter and 1.5mm thick vertical supports spaced at 1.5m center to center and 8mm thick toughened glass including fabricating ,fixtures, errecting , necessary welding , grinding , finishing, buffing to stainless steel pipe etc. complete Upto 1st Floor
Above 1st to 12th floor and terrace
Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. Upto 1st Floor
Above 1st to 12th floor and terrace
Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface. (excluding the primer coat)etc. complete. Upto 1st Floor
Above 1st to 12th floor and terrace
Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat, scaffolding if necessary , and watering the surface for two days etc complete. Upto 1st Floor
Above 1st to 12th floor and terrace
Supply and Installation of translucent roof with DPI Flux standing seam multicell polycarbonate panel system. The system with complete assembly of co extruded UV protected multicell panels incorporated into a complete system. Co-extruded UV protected polycarbonate panel system of min 12 mm thick of 900 mm (min.) width with angular daylighting concept. Panels shall have minimum six layers with truss bridge design for higher flexibility & strength. Panels with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with double tooth grip lock locking mechanism and will be secured on MS structure (will be paid Separately) with 3 One Numbers self-drilling screws & trapezoid SS fasteners holding the base of the standing seam offering best stability having a pull-out load of min. 7000N (7KN) tested as per ISO 6892:1998 and IS 1608: 2005, as per design requirement. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall not be more than 1.6 W/m2K as per EN ISO 10077-2:2018. Panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends as required. Panel shall be fixed over MS structural steel/MS purlin (paid separately) conforming to the detail technical specifications as per approved architectural drawings. Trained and factory authorized labour with supervision to complete the entire panel installation as per drawing & direction of the engineering in charge. Colour: As per Approval. Approved Make: FLUX by DPI Daylighting or approved equivalent The 12mm thick panels shall be used for a roofing height of upto 15 mtrs. Upto 1st Floor
Above 1st to 12th floor and terrace
Providing and fixing 12mm thk toughened etched glass as per the design, as per the design. Glass to be fixed at top & bottom in heavy guage aluminium 'c ' channel concealed in floor & boxing. Cost to be inclusive of silicon sealant to the periphery of the glass as directed. Upto 1st Floor
Fire exit and floor identification signage as per manufacturer's specifications, ADA compliant and modular system, As directed by Engineer-in-charge
Providing and fixing on walls/ ceiling/ floors, 50 mm dia heavy grade having embossed asISI Mark galvanised iron pipes weight of 6.33 Kilogram/meter with necessary fittings.and remaking good the demolished portion and primer of anti corrossive oilpaint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. For Municipality Inlet connection
Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. For Shaft Water supply
Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Upto gr floor
Above 1st floor
Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. For Toilet Water supply Upto gr floor
Above 1st floor
Providing and fixing 8 cm rigid PVC Nahani trap including PVC grating ,bend, connecting piece of UPVC pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) For Toilets Upto gr floor
Above 1st floor
Providing & Fixing 100mm diameter Nahani trap Jali in steel finish with necessary fixing required to make the item well functional. For Terrace,Toilet
Providing and laying chequered tiles of approved quality of size 30 cm x 30 cm, confirming to corresponding I.S. for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete
Providing and fixing European type white glazed earthen ware water closet pan with UPVC seat and lid with chromium plated brass hinges and rubber buffers including UPVC and vent pipe up to the out side face of wall 10 litre enameled low level flushing cistern with fittings pipe stop tap brackets for fixing cistern 32 mm dia. UPVC flush pipe with fittings and clamps, 20 mm dia. UPVC over flow pipe, mosquito proof couplings G.I. chain and pulley, with water Jet and fitting including cutting and making good to the walls and floors testing etc. complete. (prior approval of sample and brand by Ex. Engineer is necessary before use)
Providing and fixing white glazed earthenware lipped flat back/corner type Urinal with PVC 5 liters flushing cistern with fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32 mm diameter P.V.C. flush pipe with fitting including lead soil pipe, lead trap and soil pipe connection up to the outside face of wall. GF Toilets
Providing and fixing Oval Type Under Counter Wash Hand Basin of 420 x 590 x 195mm size with pillar cock, C.P.Angular stop cock, long thread of approved make continental including SS bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 mm thick fixed on Black Kadappa Framework, etc. Complete as directed by Engineer in charge. For Internal toilets
Providing and fixing C.P. 2 Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge
Providing & fixing 2-way Bib cock JAQUAR MAKE, ORNAMIX Model No. 10041etc. complete.
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 100 mm diameter
150 mm diameter
Providing and fixing heavy ISI marked single lever concealed diverter for bath & shower system Rain shower & its accessories. (Mixer Cat. No. CON- 421 Jaquar make OR consider equivalent make)
Providing and fixing Health Faucet with one metre long easy flex tube in chrome finish and wall flange For Internal Toilets
Providing and fixing toilet paper holder : C.P. Brass For Toilets
Providing and fixing ISI marked make CP brass liquid soap dispensers with CP brass bracket capacity 250 ml. For Bath area
Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. UPTO 1st
Above 1st to 12th floor and terrace
Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete
Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.
Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.
Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap
Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and C.I. lid cover of 75Kilogramwith lid and frame fixed in cement concrete.
RWH - Shallow Percolation Pit providing, constructing 2.0m deep shallow depth percolation pit comprising of 1.0m dia pre-cast RCC rings, 300mm thick side filling around outside of RCC rings (annular space) with 40mm size boulders including filling of percolation pit up to 0.5m depth (from bottom up) with 25-75mm clean washed gravels followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs etc. including arrangement for inlet & outlet pipe, excavation & backfilling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge
Providing and fixing in position factory made precast Glass fiber reinforced concrete (GRC) as per approved manufacture's specification and as per approved drawings. The thickness of GRC panel should not be less than 20 mm with minimum 20 mm thick GRC pads acting as stifners. Colour and tecture should be approved by Engineer incharge. Fixing of GRC panel on primary structure shall be doen by dry claddign method with the help of SS screw/ nut bolts fixtures, MS angle cleats, fissurs plug and Dowel pin etc. in porper alignment, line and level as per the approved drawing, Finishng with GRC powder fillign the joints with paintable silicon sealant neatly between GRC panel and primary strcutre to provide one piece look including moulding and cornice at junction of column and beams as per approved drawing, includign necesary MS fabrication work to support GRC strcuture, necessary scaffolding at all levels and staging etc. Complete includign cost of necessary machineries for installation, all necessary accesories, adhesives, hardware, cost of material, labour, transportation, scaffolding, loading, unloading all leads and lifts and all applicable levies, taxes, maintainance upto one year from the certifed date of completion etc. complete as per apporved drawign and as directed by engineer. Upto 1st Floor
Above 1st Floor
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. +AC subwork qty -610 Mtr
Concealing of provided G.I. pipe/H.G. screwed conduit/PVC pipe inwall/floor/false ceiling complete as per specification No:WG PW/CW
Supplying and erecting 20mm dia. corrugated flexible polypropylene conduit
Supplying and erecting 25 mm dia. corrugated flexible polypropylene conduit
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with PVC accessories on wall /ceiling as per specification No: WG-MA/CON.
Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with PVC accessories on wall / ceiling as per specification No: WG-MA/CON.
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
Supplying and erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying and erecting mains with 3x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type bell-push 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type Two way switch 6A / 10A (2 Module), duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 32A, DP key tag switch with key tag, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 3 pin 6A multi socket with safetyshutter, duly erected on provided plate and box with wiring connectionscomplete
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type USB Charger socket of 1 Module with nominal output voltage of 5V DC ±5% and nominal output current of 5 V - 750 mA , duly erected on provided plate and box with wiring connections complete.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module duly erected.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 1 module complete duly erected.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 2 module duly erected.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 module duly erected.
Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting 16 to 32 A, 10kA, DPMCB suitable to fix in 2 module of modular switch in provided box complete & duly concealed with necessary material and connected.
Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/ HW
Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW
Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
Point wiring for independent plug in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW + smart DB IP qty - 52 Nos.
Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WGPW/CW
Concealing of provided M.S./ PVC switch box in wall with finishing as per specification No: WG-PW/CW
Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/ conduit as per specification No. WG-TW
Supplying & erecting 20 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW
Supplying & erecting 100 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping /conduit as per specification No. WG-TW
Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG- 11 as per specification No. WG-TW
Supplying, erecting & commissioning MDF Box 50x50 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW
Supplying, erecting & commissioning MDF Box 100x100 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW
Supplying, erecting & commissioning 20 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW
Supplying, erecting & commissioning 100 pairs M.S. junction box made from min. 1.5mm thick MS sheet as per specification no. WG-TW
Supplying & erecting over voltage protection magazine suitable for 10 pair as per specification no. WG-TW
Supplying and installing, testing & commissioning of digital (hybrid) type EPABX of 6 x 32 extensions suitable upto 96 extensions complete.
Supplying, installing, testing & commissioning push button telephone instrument desk top/wall mount with caller ID & Speaker unit as per specification complete.
Supplying, installing, testing & commissioning push button telephone instrument desk top unit as per specification complete
Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC + CCTV subwork qty 15660 mtr
Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC.
Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO
Supplying and fixing 3 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC
Supplying, fixing, and configuring 24 ports, POE switch in provided rack as per specification No. WG-NWC/ENS
Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK
Supplying & erecting decorative pre-wired box type fitting/batten suitable for 4 feet, T8 LED tube light with ready to use Retrofit T8 LED 18 / 20 tube light with polycarbonate body, heat sink, integrated HF electronic driver complete & compatible to T8 / T12 LED luminaire.
Supplying, fixing, and configuring broadband ADSL router with all accessories, on provided rack as per specification No. WG-NWC/ADSL
Supplying and fixing 42 U floor mount server rack (Dimension-DxWxH – 800x1000x2070 mm) as per specification No. WG-NAS/RAK
Supplying and fixing dual-band manageable wireless 3x3 Mesh Router, high performance, 802.11 n/ac unified, concurrent access point with POE in networking as per specification no. WG-NAS/LAP2
Supplying and fixing Power Distribution Unit for networking rack comprises of 6/16A (6 Nos. sockets), 25 A modular MCB, appropriate rating fuse and indicator lamp, enclosed in black powder coated metal with necessary arrangement for fixing as per specification No. WG-NAS/RAK
Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting LED square / circular Max. 11 W downlighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1200 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mountingarrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting LED Strip light 5m Length Max. 45 W IP20 class having minimum lumens output of 800 Lumens/m, min. efficacy of 90 lumen/W, CRI>80, CCT upto 5000K, Beam Angle of 110 deg., THD<10%, p.f. >0.95, operating range of 230-270V, Life class of 30,000 Hrs. at L70B50, including driver with 1 year warranty.
Supplying LED concealed type foot / step light with aluminium body for indoor/outdoor application suitable for 4W-6W LED including driver and erecting by making necessary arrangement / recess in wall to make it flush with surface with 1 year warranty.
Making suitable size recess in any type of false ceiling for erection of flush type down lighter and finishing the background to match the original surface upto 20W.
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty.
Supplying & erecting inverter LED batten 20W tube light fitting withpolycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI>80, CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty.
Supplying & erecting UV Fly killer/ bug catcher Light Fitting having 2 x20W UV Tube Lights to cover min. area of 500 sq.ft with powdered coatedM.S./ steel body suitable to work on 230V, AC Supply having top mountingarrangement with SS chain complete and 3 core 1 mtr. flexible wire with 1 year warranty.
Supplying & erecting Aviation obstruction light consisting of yellow painted diecast aluminium alloy housing with Integral LED aviation light comprising of aluminium housing with polycarbonate enclosure complete.
Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab.
Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly paintedfor fan complete erected with PVC three core flexible cable 1 sq. mm copperPVC wire.
Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200mm complete erected in position as per specification no. FG-FN/CF
Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected,complete.
Supplying & erecting 22 SWG G.I sheet metal cawl sector shaped with 25 x 25 x 3 (mm) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 300 mm as per specification no FG-FAS/MSC
Supplying and erecting storage type water heater 35 litres capacity havingstanding loss <0.584 kWh / 24 hour / 45°C, high impact resistance engineering plastic body with anti corrosive high grade steel inner tank heating element having hard water & corrosion protection, with minimum 3 safety protections (i.e. thermostat & thermal cut-out, function valve) with total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete. specification no. AP-WH/STWH
Supplying and erecting midget type 3.0 litres instant type water heater of rustproof & shockproof ABS plastic body, high grade SS inner tank & 3kW heating element with corrosion & hard water protection, with minimum 3 safety protections (i.e. thermostat & thermal cut-out, function valve) complete with 6.5 bar pressure withstanding capacity 230/250V, 50Hz, A.C. supply with inlet and outlet, with 3 core PVC flexible copper wire leads duly tested and marking sr. no. and date of erection complete.
Providing fiber reinforced PVC flexible pipe upto 1m length with brass locking nuts and washers and clips at both ends suitable for hot water and cold water both (1 set of 2 nos.) complete.
Supplying, erecting, testing and commissioning self contained watercooler 230/250V 50Hz nominal cooling capacity of 80 litres per hour andstorage capacity 120 litres with partially stainless steel body as per specificationno. AP-WCR/WC
Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200)
Supplying, erecting, testing and commissioning of single phase input & 1 phase output 1 kVA capacity online pure sine wave UPS, with backup time of ....... hrs. PWM & IGBT based, with 0.8 to unity output pf complete with all protections as per specification no. AP-UPS + CCTV qty 1 no.
Supplying and erecting 12 V/65Ah SMF battery with battery terminal wire, dulycharged complete with 24 months warranty complete
Providing & erecting 6 m high (clear height) galvanised steel type pole with FRP coating (design having heritage type) foundation bolts having bottom of 200 mm A/F, top 100 mm A/F on provided foundation as per specification no. OH-PL/OPL
Providing & erecting 9 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 200 mm A/F, top 100 mm A/F on providedfoundation as per specification no. OH-PL/OPL
Supplying and erecting Street light bracket for erection of Double fitting made from 40 mm. dia ‘B’ class G.I. pipe 1.0 m. in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. FGBKT/ BPC
Supplying and erecting Street light bracket for erection of Single fitting on tubular welded pole with 40 mm. dia 1.0 m. length “B” class G.I .pipe along with pole cap of 125mm dia 600 mm long duly welded as per specification no. FG-BKT/BPC
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU + AC subwork qty 2700 mtr
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
Supplying, erecting & marking SPMCB 0.5A to 5A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as perspecification no. SW-SWR/MCB
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
Supplying, erecting & commissioning 4 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specificationno. SW-SWR/MCB
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.+AC subwork qty 24 nos + solar subwork qty 20 nos.
Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. copperconductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copperconductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU + solar subwork qty 255 mtr
Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copperconductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 3 core 4 sq. mm. copperconductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 3 core 6 sq. mm. copperconductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU + fire fighting subwork qty 130 mtr
Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 3 core 10 sq. mm. copperconductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying & erecting G.I. pipe ‘A’ class 50 mm dia. erected for enclosingXLPE armoured cable on wall/pole as per specification no. CB-CE
Supplying & erecting G.I. pipe ‘A’ class 75 mm dia. erected for enclosingXLPE armoured cable on wall/pole as per specification no. CB-CE
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 120 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete.
Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete.
Excavating soft murum / soft soil road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good complete. + fire fighting subwork qty 90 qmtr
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 9m & 10m high octagonal /conical GI pole).
Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (above 6 m to 9 m poles)
Supplying & erecting minimum three & above star rated Centrifugal water pump (Monoblock), 415 V, three phase 50 cycles A.C. supply of 11.25 KW/ 15 HP with discharge 1480/540 Litres per Minute (LPM) for head of 24/74 m and 80 mm suction/ 65 mm delivery pipe, on provided C.C. foundation as per specification No. WP-CGP
Supplying and erecting pump protection relay comprising current sensing phase failure and UV+OV relay with dry run and overload protection suitable for 3 phase pumps
Supplying & erecting flat flexible 3 core 6 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete + solar subwork qty 550 mtr
Supplying & erecting Water level controller 230/415 V, A.C. , Four way under ground & Over head tank operation only.
Supplying & erecting automatic control panel for 3 Ph, 415 volt, /centrifugal pump set up to 10 - 15 HP consisting of Star Delta starter having relay range 13-22 Amp, S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc.
Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps).
Supplying and erecting ISI mark GI pipe 65 mm. dia. ‘B’ class at position with accessories complete as per specification no. CW-PLB/GP
Supplying and erecting ISI mark GI pipe 75/80 mm dia. ‘B’ class at position with accessories complete. Specification no. CW-PLB/GP.
Supplying and erecting non return valve 65 mm dia in position made of gun metal complete.
Supplying and erecting CI flange 65 mm. dia with necessary nuts bolts and washers with rubber seal in position complete.
Supplying and erecting CI flange 75/80 mm. dia with necessary nuts bolts and washers with rubber seal in position complete.
Supplying and erecting 75/80 mm dia. gun metal sluice valve at position with necessary materials complete.
Supplying and erecting 0-100 lb/sq. inch pressure gauge having 4" dia complete with socket for 1/2" GI pipe complete.
Providing & erecting Hot dipped galvanized ladder type cabletray manufactured from 16 swg (1.6 mm thick) GI sheet of 500 mm width & 100 mm height comprising all required standard accessories.As directed by Engineer in charge.
Providing & erecting hot dipped galvanised ladder type cable traymanufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 100mm height comprising all required standard accessories
Providing & erecting hot dipped galvanised ladder type cable traymanufactured from 16 SWG (1.6 mm thick) GI sheet of 200 mm width & 100mm height comprising all required standard accessories.
Providing & erecting hot dipped galvanised ladder type cable traymanufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 100mm height comprising all required standard accessories.
Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 400 mm width & 20 mm height complete with necessary hardware.
Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 500 mm width & 20 mm height complete with necessary hardware.
Supplying and erecting 250 kVAr, 3 phase, 50 Hz., Power contactors Derated for microprocessor APFC controller with MPP / APP type capacitor with 525 V and having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours with , consisting of suitable steps of MPP / APP type capacitor units with detuned aluminium filter 7% reactors with circuit breaker as main incomer and MCCB for each branch protection, as perspecification no CP-ED/APFC
Supplying and erecting 125 kVAr, 3 phase, 50 Hz., Power contactors Derated for microprocessor APFC controller with MPP / APP type capacitor with 525 V and having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours with , consisting of suitable steps of MPP /APP type capacitor units with detuned aluminium filter 7% reactors with circuit breaker as main incomer and MCCB for each branch protection, as perspecification no CP-ED/APFC
Supply, Installation, Testing and Commissioning of Chandelier's (brass and glass crystal material) similar/equivalent approved by the Architect/Engineer-in-charge of three tier height (upto 6ft high and width upto 5') as per appropriate lux levels & fixing Incandescent light fittings (upto 25 watts each) to be achieved for the specific use of the space. Item to inlcude proper packing of the chandelier and transporation to site in one piece good condition. Any breakage of glass crystal would have to be replaced by the contractor with no extra cost to the client. Item to include provision of hook in the ceiling to take the weight of the chandelier and covering the brass pipe or rod exposed after suspending the chandelier with a velvet cloth to hide the chain. Item to also include provision of all Incandescent lamps in the fixture. Item to be paid once the light fitting is fitted on site and is in perfect condition. Item to be also providing necessary pulley mechanism for repairs & maintenance.
Supply, Installation, Testing and Commissioning of Wall Lights of 300-450mm height with 10 W LED lamp as per similar/equivalent approved by the Architect/Engineer-in-charge/ consultant. Item to inlcude proper packing of the chandelier and transporation to site in one piece good condition. Any breakage of glass would have to be replaced by the contractor with no extra cost to the client. Item to include provision of fising mechanism at the location given in the drawing. Item to also include provision of all lamps in the fixture. Item to be paid once the light fitting is fitted on site and is in perfect condition.
Supply & instllation of Wall-mounted 5-7W compact updown light emission designed to use monochromatic Warm white (3000K) & Neutral white (4000K). Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Extruded aluminium section with inner grooves to fix the top and bottom rings (grade 6063) Ø100 x 2.5mm thickness, die-cast aluminium glass fixing top and bottom ring (ADC12) Ø100mm with clear toughened glass diffuser of 4mm thickness with ceramic black coated on outer corner siliconed to ring. Die-cast aluminium heat sink for excellent thermal management. Single cable entrance via black PG7 cable gland, Die cast aluminium base for surface mounting on wall (ADC12). All external screws are made of stainless steel. Clear silicone gasket. Protection class IP65. Mechanical resistance IK07. Acid treatment & pure polyester powder coated graphite grey / anthracite grey / jet black. The luminaire's built-in LED module are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21). Operating ambient temperature range is from -15°C to +50°C. Beam angle 15° / 25° / 40°, colour rendering index (CRI)>80. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >80%, Power factor >0.90, THD <10%, Surge protection 2.5KV. Luminaire dimension : 145mm length x 100mm width x 210mm height. CE & BIS Certified. Warranty 5 years (Gazebo Lights - L1)
Supply & instalaltion of spike mounted compact 5-7W spot light designed to provide directional light. Beam angle 15° / 25° / 40°. Luminaire made of pressure die cast aluminium alloy of high corrosion resistance and non corrosive A2 stainless steel fasteners. Clear toughened glass of 4mm thickness. Surface mounting spike made of polypropylene black. Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Swivel range of 0° - 90°. Single cable entrance M10 cable gland. Protection class IP66.Mechanical resistance IK06. Pure polyester powder coated graphite grey / anthracite grey / jet black. Available colour temperature 3000K / 4000K / 5700K, Colour rendering index (CRI)>80. SDCM-3 MacAdam. Supply & instalaltion of LED module with expected service life of at least 60,000 operating hours.Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Luminaire dimension : 101mm length x 90mm width x 330mm height. CE & BIS Certified. Warranty 5Years (Tree Uplighter- L2)
Supply & instalaltion of spike mounted 3-4W compact spot light designed to provide directional light. Beam angle 8° / 12° / 24° / 40° / 60° / 40°x11°. Luminaire made of pressure die cast aluminium alloy of high corrosion resistance and non corrosive stainless steel fasteners. Clear toughened glass of 4mm thickness. Surface mounting spike made of polypropylene black. Hybrid optical lens for higher efficiency, lower optical losses with optimum glare suppression. Swivel range of 0° - 90°. Single cable entrance M10 cable gland. Protection class IP66. Mechanical resistance IK06. Pure polyester powder coated graphite grey / anthracite grey / jet black. Available colour temperature 3000K / 4000K, Colour rendering index (CRI)>80. SDCM-3 MacAdam. Supply & instalaltion of LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Luminaire dimension : 93mm length x 90mm width x 320mm height. CE & BIS Certified. Warranty 5years (Blush Uplighter - L3)
Supply & instalaltion of surface mounted 16-20W compact spot light designed to provide directional light. Beam angle 15° / 25° / 40°. Luminaire made of pressure die cast aluminium alloy of high corrosion resistance and non corrosive A2 stainless steel fasteners. Clear toughened glass of 4mm thickness. Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Swivel range of 0° - 90°. Single cable entrance M10 cable gland. Protection class IP66. Mechanical resistance IK06. Pure polyester powder coated graphite grey / anthracite grey / jet black. Available colour temperature 3000K / 4000K, Colour rendering index (CRI)>80. SDCM-3 MacAdam. K- Lite LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Luminaire dimension : 113mm length x 84mm width x 117mm height. CE & BIS Certified. Warranty 5Years (Object Light for Sculpture - L4)
Supplying & erecting integral post top lantern fixtures (globe type) suitable for LED lamp upto 12 W consisting of aesthetic round clear acrylic top cover, cast aluminium pole cap on provided pole /bracket as per specification no. FGODF/PTL (Pearl Lighting - L7)
Supply & instalaltion of Strix 3w LED Garden Light 450lm LED Lumens, Dimension 90x1506mm, Made up of Extruded Al Tube, Pure Polyster Powder Coated finish, Non Yellowing UV Stabilized Clear Acrylic Rod, Mounting Spike Arrangement, Non Integral Constant Current Power Supply 24v, IP67 1.25Amps 30w, Operating Voltage Range 100-270v AC., Operating Temp. - 15degree C. to +50 Degree C., CRI>80, CCT 2700K/ 3000K, Life L70 60000hrs., SDCM<3, Power Factor> 0.9, THD <15%, Surge Protection 1kV, Efficiency >75%, Syymetrical Light Distribution, IP65, CE and BIS Marked, Warranty 5Years (Stix Light - L9A)
Supply & instalaltion of Strix 3w LED Garden Light 450lm LED Lumens, Dimension 90x1306mm, Made up of Extruded Al Tube, Pure Polyster Powder Coated finish, Non Yellowing UV Stabilized Clear Acrylic Rod, Mounting Spike Arrangement, Non Integral Constant Current Power Supply 24v, IP67 1.25Amps 30w, Operating Voltage Range 100-270v AC., Operating Temp. - 15degree C. to +50 Degree C., CRI>80, CCT 2700K/ 3000K, Life L70 60000hrs., SDCM<3, Power Factor> 0.9, THD <15%, Surge Protection 1kV, Efficiency >75%, Syymetrical Light Distribution, IP65, CE and BIS Marked, Warranty 5Years (Stix Light - L9B)
Supply & instalaltion of Strix 3-4W LED Garden Light 450lm LED Lumens, Dimension 90x1106mm, Made up of Extruded Al Tube, Pure Polyster Powder Coated finish, Non Yellowing UV Stabilized Clear Acrylic Rod, Mounting Spike Arrangement, Non Integral Constant Current Power Supply 24v, IP67 1.25Amps 30w, Operating Voltage Range 100-270v AC., Operating Temp. - 15degree C. to +50 Degree C., CRI>80, CCT 2700K/ 3000K, Life L70 60000hrs., SDCM<3, Power Factor> 0.9, THD <15%, Surge Protection 1kV, Efficiency >75%, Syymetrical Light Distribution, IP65, CE and BIS Marked, Warranty 5Years (Stix Light - L9C)
Supplying and erecting integrated LED Bollard Cylindrical /Cubical shaped 800mm 8W IP65 & IK10 class having extrusion aluminium housing with polycarbonate diffuser, having system lumens output of Min. 800 Lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-240V, inbuilt surge protection of 2 kV, Life class of 25,000 Hrs. at L50B50, including driver complete with 2 Year warranty as per specification No FG-ODF/FLS2.
Supply & instalaltion of Decorative poles 5 meter with 20W Decorative Susspended Fixting, Pole shall be Made of Shockproof composite Material ( Steel -Expanse-resin) UV-Rays Stablized, rust and corrosion free, Moulded colors in paste, no maintainance or painting required. Insulation class II, desired colour as per instructed by Enginneering Incharge. Pole shall have Built-in control box with service door and safety rope. The control gear tray is prewired with MCB, terminal connectors for loop-in / loop-out arrangement , The foundation bolt holes in the base plate are designed to be elongated for fine adjustments / alignment of the pole during installation. Base plate made of steel grade E250 & foundation bolt M16 X300 of grade 4.6. Inclusive of supply and installation of bakelite sheet with 6A SP C curve MCB & stud type terminal block suitable for terminating the respective cable. The fitting should be connected with Copper Flexible wire of 3CX2.5 Sq.mm. The PU colour of the pole as well as bracket to mount minimum 2 suspended Decorative Light fixtures shall be guaranteed for at least 5 years from date of handing over the installation. (Pole for Light & CCTV)
Supplying, erecting ,Testing & commissioning Ceiling or wall Mounting type 630A Capacity at 40oC ambient temperature Sandwich type Aluminium Conductor tin plated at joints /Aluminium conductor Silver flashed copper bimetal contact having purity not less than 99.6% with suitable for (3L+ N) 415V, 50 Hz A.C Supply with 100% Neutral+ enclosure as integral earth (PE) with IP 54/55 Protection,36/40KA short circuit rating for 1sec, Insulation Class F (155 C) , casing made of minimum 1.5mm hot dipped / electro Galvanized /Epoxy powder coated steel sheet enclosure having Mechanical strength certification up to IK10 with required shade of paint having overall cross sectional area not more than 0.0170 sq. Mtr., complete assembly must comply to seismic zone 4, with necessary accessories Like suspension bracket, wall bracket holder/ fixing accessories with Horizontal / Vertical G.I. Support at required interval with External Double run 50x5mm Aluminium earthing strip or Internal Integral Earth complete confirming to IEC 61439-6 as per specification
Supplying, installing, testing and commissioning of Flange end with Adaptor box, as per site requirement suitable for Aluminium 630A 3 phase 4 wire 415V, 50 Hz A.C ,36/40kA short circuit rating for 1 sec Sandwich type Aluminium BBT. with necessary accessories complete
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 185 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, installing, testing & commissioning of Tap off box with interlock arrangement on existing Air Insulated / Sandwich type bus trunking/ rising mains for 32A to 125A 3 phase 4 wire 415V, 50Hz AC Supply made with High Grade Plastic enclosure with provision of MCB/ MCCB without (MCB/MCCB) complete as required confirming to IEC 61439-6 as per specification
Supplying, installing, testing & commissioning of Tap off box with interlock arrangement on existing Air Insulated / Sandwich type bus trunking/ rising mains for 125A to 200A 3 phase 4 wire 415V, 50Hz AC Supply made with 1.5 mm thick sheet metal enclosure (IP54/55) duly powder coated with provision of MCCB( without MCCB) complete as required confirming to IEC 61439-6 as per specification
Supplying, installing & Commissioning Vertical or Horizontal 90 Degree Elbow for Sandwich type Aluminium Compact bus trunking/ rising mains Suitable for 630A, 3 Phase 4 Wire 415 V, 50 Hz AC Supply, 36/40kA short circuit rating for 1 sec Made of minimum 1.5mm Thick Galvanised sheet metal enclosure (IP54/55) duly powder coated with all necessary accessories complete confirming to IEC 61439-6 as per specification
Supplying, installing & Commissioning Vertical or Horizontal Tee Elbow for Sandwich type Aluminium Compact bus trunking/ rising mains Suitable for 630A, 3 Phase 4 Wire 415 V, 50 Hz AC Supply Made of minimum 1.5mm Thick Galvanised sheet metal enclosure (IP54/55) duly powder coated with all necessary accessories complete
Supplying, installing & Commissioning of Plug in Points on provided Sandwich type Aluminium Compact bus trunking/ rising mains Suitable for 630A, 3 Phase 4 Wire 415 V, 50 Hz AC Supply,,36/40KA short circuit rating for 1sec Made of minimum 1.5mm Thick Galvanised sheet metal enclosure (IP54/55) duly powder coated with all necessary accessories complete.
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (36 poles) or TP MCB of 12 ways (36 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1
Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 35 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
SITC of Electric Traction Passenger cum Stretcher Lift with· Rated capacity :- 16 Passenger/1088Kg · Floors :- G+12 upper floor (13Stops/13Landings) · Travel :- 21 to 54.6 mtrs· Location of Lift Machine:- MR/MRL· Rated speed :- 1.5 mps VS· Car/Landing door clear opening of 1000 mm wide x 2000 mmhigh· Clear Car size of 2000 mm wide x 1500 mm deep x 2250mm high · Lift shaft available having clear size of 2400 mm wide x 2400 mm deep, 1500 mm Pit depth, 4800 mm Overhead. for rear side · Lift shaft available having clear size of 2300 mm wide x 2300 mm deep, 1500 mm Pit depth, 4800 mm Overhead. for atrium side lift· Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory).· Lift car enclosure made from 304 grade solid(non-claded) sheet of 1.5mm, thick with hairline finish for side walls with rear side plane glass panels per drawing attached, for full height with 304 grade solid(non-claded) framing complete with car frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails(3sides), mirror(side wall), emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. · COP with SS face plate having metallic push buttons with Braille Code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor· LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille Code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings· Lift controller of simplex full collective based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port, The Controller shall have necessary Protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. ,various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self leveling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with Real-time clock management and Handheld keypad with LCD screen for view and setting of parameters, The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class · ARD complete with necessary SMF VRLA batteries· Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for 90 days with 20” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. · Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid Test Certificate issued by NABL accredited or Independent Test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength· Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work· Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT.· General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning2783302(17.1.18)+152654x6(A1-5 for above 7 upto 12 th floor)+13460x2Nos.(Add On C)
SITC of Duplex Lift control system for two nos. microprocessor/PLC based simplex lift controllers along with necessary software with programming and hardware e.g. logic board, necessary communication/control/data cabling laying in rigid PVC conduits/trunking etc. complete
SITC of Triplex Lift control system for three nos. microprocessor/PLC based simplex lift controllers along with necessary software with programming and hardware e.g. logic board, necessary communication/control/data cabling laying in rigid PVC conduits/trunking etc. complete.
Supplying installing testing and commissioining of glass(laminated safety glass) Lift car enclosure for left & right side with rear panels of 16 passenger lift car in leu of 1.5mm thick SS 304 grade solid(non-cladded) with all accessories etc. necessary for the normal safe functioning of lift installation complete as per specifications (this job includes cost credit for lift car side enclosure SS panels not required to install as glass to be installed)
Supplying, erecting, testing and commissioning of 28HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete.
Supplying, erecting, testing and commissioning of 18HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longerpiping range upto 1000 metre operation in cooling mode with inverter/ digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete
Supplying, erecting, testing and commissioning of 16HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longerpiping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete.
Supplying, erecting, testing and commissioning of 14HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete.
Supplying, erecting, testing and commissioning of 12HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 2.6TR (918 cfm) to 2.8TR ( 1100 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oilcharge as per requirement during installation.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 3.0TR (1100 cfm) to 3.2TR (1165 cfm) having EER as per BEE standards and specifications, suitable as per siterequirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coatingsuitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oilcharge as per requirement during installation
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 3.3TR (1165 cfm) to 4.0TR (1218 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation.
Supply, installation, testing and commissioning of VRV / VRF based ductable type, high static room/indoor unit (IDU) having nominal cooling capacity of 4.1TR (1640 cfm) to 5.0TR (2000 cfm) having EER as per BEE standards and specifications with evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, in built drain pump, expansion device, cordless remote control with necessary controls and electrical terminal to receive power supply, etc. having anti-corrosive coatingsuitable for coastal area and decorative slim dimension suitable for ceiling suspended arrangement with an electronic control console and any additional refrigerant and oil charge as per requirement during installation complete.
Supply, installation, testing and commissioning of VRV / VRF based ductable type, high static room/indoor unit (IDU) having nominal cooling capacity of 2.5TR (980 cfm ) to 3.0TR (1200 cfm) having EER as per BEE standards and specifications with evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, in built drain pump, expansion device, cordless remote control with necessary controls and electrical terminal to receive power supply, etc. having anti-corrosive coating suitable for coastal area and decorative slim dimension suitable for ceiling suspended arrangement with an electronic control console and any additional refrigerant and oil charge as per requirement during installation complete.
Supplying and installation of high pressure grade required size copper connection Y or T- Joints/refnet complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testingfor leakages confirming the normal operation of the VRV/VRF air conditioning system
supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 6.4mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete.
supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 9.5 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete
supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 12.7mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete
supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 15.9 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete.
supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 19.1mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers withinsulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages,fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete.
supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 22.2mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiation with OEM standards of VRV/VRF air conditioning system complete
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 28.6 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV /VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 34.9 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV /VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 41.3 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Providing vaccumising the airconditioner system to 200 micron and charging with refrigerant R32 for AC unit.
Supplying and erecting rigid UPVC conduit 50 mm in dia. conforming to I.S. with required number of couplings, PVC bushes, check nuts etc. complete dia. with PVC accessories on wall /ceiling as per specification No: WG-MA/CON, para no. 1.1.1 for Drain Pipe complete with Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having 9 mm thickness and inner diameter / sizes 25 mm as per specification no ESD-ENR
Supplying, installing, testing & commissioning split type room air conditioning unit 2.8TR to 3.2TR capacity with refrigerant R32 415V, 50 Hz, A.C. supply having 1 no of air handling unit (Mega split) mounting type complete with temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC
Supplying, erecting ,Testing & commissioning Ceiling or wall Mounting type 400A Capacity at 40C ambient temperature Air Insulated type Bus Trunking Aluminium Conductor having purity not less than 99.6% with Tin plated at joints suitable for (3L+N) 415V, 50 Hz A.C Supply with 100% Neutral+ enclosures as integral earth (PE) BBT Shall type tested as per IEC 61439-6 with IP 54 Protection, 25KA short circuit rating for 1sec, Insulation Class F (155 C), casing made of Galvanized / powder coated steel sheet enclosure havingMechanical strength certification up to IK10, with required shade of paint & having cross sectional area not more than 0.0270 Sq m, complete assembly must comply to seismic zone 4, with necessary accessories Like suspension bracket, wall bracket holder/ fixing accessories with , outlet cover , plug in hole as per site requirement with Horizontal / Vertical G.I. Support at required interval, with External Single Run 25x10mm Aluminium earthing strip or InternalIntegral Earth complete confirming to IEC 61439-6 as per specification
Supplying, installing & Commissioning Vertical or Horizontal 90 Degree/Tee Elbow for Air Insulated type bus trunking/ rising mains of capacity 400A, 3 Phase 4 Wire 415 V, 50 Hz AC Supply,25kA short circuit rating for 1 sec Made Galvanised sheet metal enclosure (IP54) duly powder coated with all necessary accessories complete confirming to IEC 61439-6 as per specification.
Supplying, installation, testing and commissioning of Flange end as per design requirement & site condition suitable for Aluminium 400A, 3 phase 4 wire 415V, 50 Hz A.C ,25kA short circuit rating for 1 sec for Air Insulated type BBT. With necessary accessories complete confirming to IEC 61439-6 as per specification
Termination arrangement at Panel (Inclusive of Adopter Box, connecting links, Hardware, copper flexible if required; in line with OEM's requirement)
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. + solar subwork qty 2060 Kg
Supplying and erecting GI sheet 0.6 mm (24 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.
Supplying and erecting GI sheet 0.8 mm (22 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.
Supplying and erecting GI sheet 1 mm (20 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint
Supply, fabrication, installation and testing of flexible canvas connections constructed between ductable unit/dampers/ducting of suitable size with fire resist flexible double canvas sleeve complete.
Supplying and installing of collar damper of galvanised iron material of upto 120 microns for anti corrosive resistance for supply air grill of suitable size.
Supply, installation, testing and commissioning of manually operated, opposed blade, duct mounted, flanged volume control dampers of required sizes in GI construction with operating mechanism, mounting arrangement, rubber refrigerant kits etc. complete
Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC
Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.7TR to 2.0TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC
Supply & Installation of closed cell structure Elastomeric foam based on synthetic nitrile rubber with outer side covered with Black glass cloth.(BGC). The insulation material shall have fire performance of Class O acc. to building regulations. Fire propogation shall be tested acc. to BS476 Part 6:1989. It shall be FM approved & UL94 tested. a) 13 mm thick for internal lining of duct - for Supply Air Ducting
Supply & Installation of closed cell structure Elastomeric foam based on synthetic nitrile rubber with outer side covered with Black glass cloth.(BGC). The insulation material shall have fire performance of Class O acc. to building regulations. Fire propogation shall be tested acc. to BS476 Part 6:1989. It shall be FM approved & UL94 tested. b) 19 mm thick for internal lining of duct - for Fresh Air Ducting.
Supplying and erecting 40 mm Chlorinated polyvinyl chloridepipe (CPVC), thickness 3.8 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement as perspecification No. ESD-HWP/CPVC
Supplying and erecting 50 mm Chlorinated polyvinyl chloridepipe (CPVC), thickness 3.8 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement as perspecification No. ESD-HWP/CPVC
Supplying and erecting 75/80 mm Chlorinated polyvinyl chloridepipe (CPVC), thickness 3.8 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement as perspecification No. ESD-HWP/CPVC
Supplying and erecting 110 mm Chlorinated polyvinyl chloridepipe (CPVC), thickness 3.8 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement as perspecification No. ESD-HWP/CPVC
Supply & Installation of 20 mm thick Open Cell Nitrile Insulation. It shall be FM approved & UL94 tested. Thermal conductivity of Insulation should be 0.034W/mk at 25deg c.
Supply, fabrication & erection of insulated flexible duct of 100mm. dia with necessary clamping arrangements and supports. insulation density 16kg/m^3, insulation R value of 0.64 sq.mk/w.
Supply, installation, testing and commissioning of Timer based sequential controller for Inverter cassette Units. It should give command to Units to operate on alternate basis.
Supply, installation, testing and commissioning of extruded aluminum powder coated 4 way Square diffuser with volume control dampers as per the approved drawings and specifications. Square diffuser should be flush with the ceiling. Color should be match with the color code of ceiling. Outer Size as per following: air. 600 x 600 mm Supply -(Neck Size 375 x 375 )
Supply, installation, testing and commissioning of extruded aluminum powder coated 4 way Return diffuser without volume control dampers as per the approved drawings and specifications. Color should be match with the color code of ceiling Outer Size as per following:600 x 600 mm Supply - ( Neck Size 375 x 375 )
Fresh air louvers with Bird Screen:Supply, installation, testing and commissioning of alumininum powder coated fresh air louver for TFA units with bird screen as per the approved drawings and specifications.
Supplying & fixing of underdeck insulation of Nitral insulation with one side Aluminimum foil conforming to IS 8183 & thickness 25 mm so that the minimum Thermal resistance should be R-1.65sq.m.K/W at mean temp 25 Deg C. The insulation should conform to Non combustibility, Class P (not easily ignitable), Class 1 and Class’O’ as per fire standards BS 476 part 4, 5, 6, and 7. The one side of the insulation should have factory laminated Aluminum foil vapour barrier. The insulation should be applied with suitable adhesive and anchored with rawl plug or dash fasteners (600mm c/c), G.I/ Aluminum channel runners system and GI. Lacing wire (placed diagonally to hold insulation).contractor as per site requirement.
Supply & Installation of starter panel: Supply of Starter panel with IP55 protection & VFD with bypass arrangement. Panel should be include with necessary control system for Marine light, door limit switch interlocking, NO/NC contact in case of fire to turn off the AHU, On/Off/Trip/Auto-mannual switch indicator & Status, Including necessary terminal, Relay & control cabling for limit switch, Marin light.)Note :- 1. Electrical Cabling from Starter Panel to Fan will be in scope of Electrical Contractor.
Supplying, installing, testing and commissioning of Cabinet type Pressurization / Make up Air Supply fan for lobby / Auditorium as per specifications.Fan shall be thermally rated for 250°C for 2 hours as per [BS-7346 Part-2 : 1090] Class-B. Motors shall be suitable for 415 +10% volts, 50 cycles , electrical starter panels with power / control cabling for 3 phase fans and logic controller with necessary control cabling will form a part of the same, static pressure shall be as indicated . Fans shall be activated from fire signal from fire alarm system .Fan shall be with flexible fire proof flexibel connection at inlet and outlet.Note :- 1. Electrical Cabling from Starter Panel to Fan will be in scope of Electrical Contractor. 5000 CFM - 65mmwg - Basement Lift lobby Pressurization.
Supply, installation, testing and commissioning of Computational Fluid Dynamics CFD Analysis and simulation to ensure proper placement of fans to comply with the air movement, ACPH, exposure levels/time of CO to persons and applicable building regulations. CFD analysis to include complete preparation and simulation study of 3D modellling, intake and extract openings available for ventilation. The scope shall cover complete basement and the contractor shall submit a complete CFD report with data sheets, graphs for review and approval of Client and Consultant. The Agency scope is to work on the coordination drawings and produce the results, any comments to be incorporated and revisions made to getthe final CFD approved by Client / Consultant. Minimum 3 runs shall be included. CD containing visual output shall be submitted.
Supply and installation of CO Sensor & Detector UL 2034 /NFPA CO detector to be installed flushmounted hard wired to Panels and with battery back up. Each Sensor shall have Output Terminals: (Screw Type)1. 24 V AC/DC2. Power grounding3. O/P 1 Linear signal CO transmitter4. O/P 2 Linear signal CO2 transmitter (Built in option)5. O/P 3 – Gas alarm (NC)6. Jumpers to choose between open or 10V signal; voltage or current outputs7. Jumper for configuring the linear output 0% or 20 % start point.8. UART port Sensor Electrical/Mechanical/Dimensions:Power Input 24 VAC/VDC±20%, 50 Hz (half-wave rectifier input);Power Consumption < 3 Watts average; Wiring Connections max 1.5 mm2 wires for screw terminal (main terminal) and spring loaded terminal; UART connector 5-pin, 2.54 mm pitch & slide connectorCO Measurement : Operating Principle Gas sensitive thick film material (MMOS) internally compensated for temperature and humidity variations, with active carbon filter with Automatic Baseline Correction (ABC) 3 Accuracy 4± 10 ppm:Measurement ranges 0 to 200 ppmGeneral Performance : Compliance with EMC directive 89/336/EEC; Operating Temperature Range 78oC to +50°C;Storage Temperature Range -20 to +70 °C; Operating Humidity Range 0 to 95% RH (non-condensing); Warm-up Time ≤ 15 minutes (more when un-powered for a long time); Step response (T1/e) 8 minutes 2; Expected Life Time - 7 to 10 years Self Diagnostics complete function check of the sensor.
Supply, Installation, Testing and Commissioning of Programmable Logic controller as per the below description and the Tender technical specs:Supply, Installation, Testing and Commissioning of PLC with main componentslike power, processor, input & output cards, an open protocol for interface with the BMS systems. PLC to be complete as per specs installed inside the Main Switchgear MCC panel,Starters for axial Fans& all accessorries. The PLC shall have a FULL MODBus / BACnet / Eithernet interface facility with the Central BMS system. Scope to include the Gateway or converter, Communication module, HVAC software in addition to the standard features.Minimum Specifications of a Controller are as follows :a) 10 x analogue inputs for CO or other pollutant sensors. (0-20mA, 0-5V and 0-10V input available).b) 16 x digital inputs for fan run/fault status.c) 1 x emergency alarm (i.e. fire) digital signal inputs.d) MODBUS, BACnet and other protocols for supervisory connection with BMS system. Built-in communication - Modbus slave serial link by means of connection on integrated RJ45 port (Modbus master/slave serial link on integrated RJ45 port).e) 3 x analogue outputs available to speed control groups of JetVent Fans, central car park exhaust fan or supply fan.f) 3 x digital outputs to drive speed control relays (for 2 speed fans) or other systems according to pollutant concentration Other Standard Details which the Basic Controller shall have are as follows:a) Programmable Logic Controller with HVAC softwareb) Dedicated PWM programmable output.c) Programmable Anagol Outputs/Inputs 0 - 10 V, 0 - 20 mA, 4 - 20 Mad) Display block for displaying the controller status: 4 LEDs (PWR, RUN, ERR and EXP) and 1 LED that can be used in the application.e) Connector for a removable terminal block (1) (2 terminals) for connecting the 24 V c/a supply.f) Rj11 Connector marked prog. Port for connecting a programming port.g) Connector for a removable terminal block for connecting analog inputs. h) Connector for a removable terminal block for connecting discrete inputs.i) Connector for a removable terminal block for connecting discrete inputsj) Rj45 connector for connection to the modbus busk) Rj45 connector for connection to the modbus busl) Five Modbus bus and expansion bus polarization and line terminato adjustment switches.m) connector for a removable terminal block for connecting the expansion bus.n) Connector for a removable terminal block to connect the power supply for a remote display unit.o) Connector for a removable terminal block, for connecting 4 discrete relay N/C outputs.p) Connector for a removable terminal block for connecting the discrete relay C/O output.g) Display with 6 command for setting the controller parameters.r) logic controller are mounted as standard on a 35mm DIN rail.Supply, laying testing and commissioning of 600/1000V copper conductor FRLS insulated PVC sheathed armoured IEC 60502 with max short circuit temperature 300C.
Supplying and erecting 160 mm(OD) PVC ducting having 6kgf/sq.cm class-3 double/selfit socket to be used for fresh air ducting complete sealing with adhesive solution with necessary accessories like reducer/enlarger , couplings & pressure/air flow monitoring PVC Valves and necessary GI hanger with clamps etc as directedd by engineer incharge.
Supplying and erecting 125 mm(OD) PVC ducting having 6kgf/sq.cm class-3 double/selfit socket to be used for fresh air ducting complete sealing with adhesive solution with necessary accessories like reducer/enlarger , couplings & pressure/air flow monitoring PVC Valves and necessary GI hanger with clamps etc as directedd by engineer incharge.
Supplying and erecting 110 mm(OD) PVC ducting having 6kgf/sq.cm class-3 double/selfit socket to be used for fresh air ducting complete sealing with adhesive solution with necessary accessories like reducer/enlarger , couplings & pressure/air flow monitoring PVC Valves and necessary GI hanger with clamps etc as directedd by engineer incharge.
Supplying and erecting 90 mm(OD) PVC ducting having 6kgf/sq.cm class-3 double/selfit socket to be used for fresh air ducting complete sealing with adhesive solution with necessary accessories like reducer/enlarger , couplings & pressure/air flow monitoring PVC Valves and necessary GI hanger with clamps etc as directedd by engineer incharge.
Supplying and erecting 75/80 mm(OD) PVC ducting having 6kgf/sq.cm class-3 double/selfit socket to be used for fresh air ducting complete sealing with adhesive solution with necessary accessories like reducer/enlarger , couplings & pressure/air flow monitoring PVC Valves and necessary GI hanger with clamps etc as directedd by engineer incharge.
Supplying and erecting 50 mm(OD) PVC ducting having 6kgf/sq.cm class-3 double/selfit socket to be used for fresh air ducting complete sealing with adhesive solution with necessary accessories like reducer/enlarger , couplings & pressure/air flow monitoring PVC Valves and necessary GI hanger with clamps etc as directedd by engineer incharge.
Supplying and erecting 32/40 mm(OD) PVC ducting having 6kgf/sq.cm class-3 double/selfit socket to be used for fresh air ducting complete sealing with adhesive solution with necessary accessories like reducer/enlarger , couplings & pressure/air flow monitoring PVC Valves and necessary GI hanger with clamps etc as directedd by engineer incharge.
Supply, installation, testing and commissioning of Recessed False Ceiling Cassette Fan with cordless remote control along with Timer and Revolving feature, suitable for insertion in 2’X2’(600 X 600mm) False Ceiling Tile Slots / Gypsum Board. Fan Should have Provision for fixing directly on plain ceilings or walls.Weight of the fan should not be more than 5.1 kg.Dimensions of the fan not more than 603(L) X 603(W) X 190(H) & CFM should be as mentioned below.Fan motor shall be operate on 1-phase, 230V, 50Hz, AC input supply.LED power should be 20W Minimum. SITC of Fan with necessary accessaries & Frame work including cabling with termination from socket to Fan.Fan CFM : 1400
Supplying, erecting, testing and commissioning of diesel generating set with alternator of 500 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 81.90 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 690 Ltr etc. on provided M20 Grade CC Foundation and obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG
Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 400 kVA up to 500 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF. Note 1) 10% reduced for new AMF panel)
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 185 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU (2Run)
Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for DG). Standard DG size is (L6000mm x W2000mm x H2250mm), so considered foundation require as 400 mm extra from all side which comes L - 6.400 mtr, W - 2.4 mtr and depth - 1 mtr.=(7.4 + 7.4) x (3.4 + 3.4) x 1 mtr = 100.64cumtr.
Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete = 5.6*2.6*0.33
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 200 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete.
Supplying and erecting GI sheet 1.6mm (16 SWG) caution board of size 250 x 200 mm duly painted with red oxide and enamel paint in Marathi and Hindi erected at position for HV/EHV installation.
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.
Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all mate
Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no. EA-EP. Cu
Supplying, installation, testing and commissioning of main fire pump(MFP / EP) suitable for water discharge of 2280 to 2850 LPM at 120 to 90 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 75kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/EP
(MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 120 to 90 m head driven by 110 HP or suitable HP capacity diesel engine at required working speed suitable for automatic operation and consisting of following :(a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520.(b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine , exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932of 2003) complete, as per specification no. FF-MFP/SSC/DP
Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 90 to 70 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 9.3 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, as per specification no. FF-MFP/JP
Supplying, installation, testing and commissioning of booster fire pump [BP] suitable for water discharge of 900 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 7.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation on with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d)Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 150 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG + FF subwork qty 38 nos
Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS
Supplying and erecting G.I. pipe ‘C’ class ERW 200 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 65 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittings complete as per specification no. FF-PP+ solar subwork qty 60 Mtr
Supplying and erecting ISI mark GI pipe 40 mm. dia ‘C” class at position with accessories complete. Specification no. CW-PLB/GP.
Supplying and erecting ISI mark GI pipe 32 mm. dia ‘C” class at position with accessories complete. Specification no. CW-PLB/GP.
Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings complete as per specification no. FF-PP
Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system.
Supplying and erecting 200 mm dia cast iron double flange ball type NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
Supplying and erecting 150 mm dia cast iron double flange ball type NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
Supplying and erecting 100 mm dia cast iron double flange ball type NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
Supplying and erecting 75/80 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV + solar subwork qty 8 Nos
Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 65 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and installing cast iron double flange Butterfly Valve of size 50 mm dia as per specification no. FF-VL/BFV + solar subwork qty 8 nos.
Supplying and erecting 75/80 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting 100 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting 150 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT
Supplying and erecting 200 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF-VL/SV
Supplying and erecting 150 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF-VL/SV
Supplying and erecting 75/80 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF-VL/SV
Supplying and erecting stainless steel double outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FFFFA/NZ
Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
Supplying and erecting M.S./CRCA cabinet for housing double hose pipe with nozzle (size 750 x 600x 250 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8"x6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)
Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV
Supplying and erecting brass orifice plate having 6 mm. thickness, 140 mm outer dia with required diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP
Supplying and erecting brass orifice plate having 6 mm. thickness, 160 mm outer dia with required diameter of inner hole at every double outlet hydrant valve as per specification no. FF-FFA/OP
Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC
Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete as per specification no. FFFA/FMC
Supplying and erecting 25 mm Ball Valve complete with PN16 pressure rating, as per specification no. FF-VL/BV
Supplying, erecting, testing and commissioning of Upright/ Pendent quartzoid bulb sprinkler, 15 mm (½") dia. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR./UP
Supplying, erecting, testing and commissioning of horizontal sidewallquartzoid bulb sprinkler, 15 mm (½") dia quartzoid bulb. NBCM Bodychrome finished, 68º C fixed temperature rating with deflector disc ofconventional construction complete as per specification no. FF-SPR/SS
Supplying, erecting, testing and commissioning of concealed quartzoid bulbsprinkler, 15 mm (½") dia quartzoid bulb. NBCM Body chrome finished, 68º Cfixed temperature rating with deflector disc of conventional constructioncomplete as per specification no. FF-SPR/CON
Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV
Supplying and erecting fire resistant mortar (20 kg) with fire resistance class S90 as per National Electrical Code (NEC) SP30-2011 suitable to seal the openings of all kinds of cables, pipes and cable support system in steel, aluminium and plastic profiles ( except hollow core conductors). The residual openings shall be closed with filler, as per specification no FF-FRM.
Supplying and fixing of self expanding, ready to use polyurethane(PU) foamsealant of minimum 750ml bottle, suitable to seal the openings of all kinds ofcables, pipes and cable support system in steel, aluminium and plastic profiles (except hollow core conductors). Sealant shall have minimum 2 hour fire rating ,conforming to EN 1366-4:2021 as per specification no FF-FRS.
Supplying, erecting, testing and commissioning vane type water flow detector 100 mm dia. with 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes.
Supplying erecting, testing and commissioning of sprinkler flexible pipe of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of 1200 mm size (UL Listed) complete as required as per specification no. FF-SPR/FHP
Supply & Installation of Stainless steel finish rossette plate of dia 75 mm for below false ceiling application as per specification
Supplying and erecting, testing and commissioning of 150 mm dia. installation control valve(Alarm Valve) of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch,cock valve complete with drain valve and bypass, test control box, ball valves, MS pipes of required size, flanges, orifice plate, gasket etc. complete as per specification no. FF-VL/ICV
Supply, Installation, testing & commissioning of Deluge valve complete with accessories, water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continuous alarm when system activates, pressure gauges, emergency releases, strainer, MS pipe of reqd. size, flanges, orifice plate, gasket etc., Wet pilot Trim (electrically operated) of size 150 mm dia.
Supply, Installation, testing & commissioning of curtain open type sprinkler having K-53 (15 mm dia) complete with socket / Tee & accessories as required . (UL listed / FM approved )
S u p p l y i n g & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.
Supplying erecting, testing and commissioning of Direct Low Pressure (DLP), automatic electrical cabinet fire suppression system kit comprises of the mild steel cylinder, hydraulic tested to 30kg/cm2 to check for leakages & burst pressure above 110kg/cm2. duly hot phosphate & epoxy powder coated internally and externally more than 65 microns or painted with 1 coat of primer and 2 coats of red enamel paint all complete. The Cylinder assembly is filled with 6 kg of clean agent gas (FK-5-1-12 UL listed) and pre-pressurized to 15/16 Bar having storage & operating temperature range of (-)17.8deg.C to 54.4deg.C with all important accessories e.g. brass assembly valve with pressure gauge, end of line plug with pressure gauge suitable to connect with provided Linear heat detection tube, complete with mounting bracket assembly, required size rubber grommets, plastic loop clamps, pressure switch and caution & cylinder Labels etc.
Supplying and erecting of linear heat detection tube (UL Listed) made from special flexible polymer material having 6 mm outside & 4 mm inside diameter suitable for working pressure of 20 bar having Red RAL 3000 colour with operating rupture temperature between 110 deg C to 120 deg C or 125 deg C to 145 deg C or 170 deg C to 180 deg C. The tube shall be flexible and shall be kink resistant having minimum bending radius of 100 mm complete erected with necessary drilling at panel wall entries duly connecting with provided end line plug fittings, with rubber grommets, plastic loop clips/clamps etc. complete with all accessories
Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300µA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FF
Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors, in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area's etc. with 3 years equipment replacement warranty IS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD.
Supplying, installing, testing and commissioning of Addressable Multisensor/Multicriteria Photo Thermal (Smoke + Heat) Detector. The detector shall have twin bi-colour LED for 360 deg viewing. The intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. It shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. This item is referred for Non-conditioning Area conforming to EN 54/VdS / UL & FM approved with 3 years equipment replacement warranty, Designed to meet UL268, 7th Edition
Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with "Break Glass" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP.
Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH.
Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 8 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP
Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM
Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/ISM
Supplying, installing, testing and commissioning of addressable fire monitor module complete as required. EN 54 or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/MM
Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU + PA system qty 14360 mtr
Supplying, installing, testing and commissioning remote response indicators suitable to operate on 5 - 28 V dc supply having FR Polymer ABS Housing complete as per specification no. FF-FAAS/RRI
Supplying, installing, testing and commissioning of repeater panel with suitable battery backup of a minimum of 24 hours in normal condition and 30 min in alarm condition, 80 backlit alphanumeric LCD display with inbuilt buzzer to indicate fault/fire alarm, manual control keys for silence/mute and to reset the FACP from the repeater station. Panel size shall not more than 175 x 275 x 65 mm conforming to EN 54 or UL approved with 3 years equipment replacement warranty FF-AFAS/RP
Supplying, erecting testing and commissioning beam smoke detector four wire single ended reflected type with 8 " receiver having digital display for easy alignment, adjustable sensitivity & heater kit for transmitter/receiver and reflector with necessary connections on suitable back box. The protection range of beam detector is 70 to 100 m.
Supplying and erecting 12V/100Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete.
Supplying, installing, testing and commissioning of 19" rack mountable 240W Dual channel Mixer Amplifier complete with LMT, control wires and other accessories.
Supplying, installing, testing and commissioning of 19" rack mountable 480W Dual channel Power Amplifier complete with LMT, control wires and other accessories.
Supplying, installing, testing and commissioning of 6W Ceiling mounted speakers with plastic / metalic grill with built in 100/70v LMT, variable wattage tapping with required mounting accessories & hardware to mount in false /true ceiling.
Supplying, erecting, testing and commissioning 15 to 30 Watts sound column or ceiling mounted complete as per specification no. FF-PA/SOC
Supplying, installing, testing and commissioning 30W Horn type speaker with built in 100/70v LMT, variable wattage tapping of 10/6/3/1.5 watts with required mounting accessories & hardware to mount on wall/ceiling / pole
Supply of Micropricessor based Voice Alarm System Controller & Router suitable for 32 zones having built in 240 W amplifier , Freq response 60 to 18000 Hz, distortion <1%, S/N Ratio >75 having memory capacity 16MB flash ROM, Max messages 255. Controller shall be EVAC Compliant, and as per EN-54-16, EN608-49 ( and recording the Massages given by user department in required format in minimum three langauges and store in ROM as per software required format.)
Supply,fixing,testing and commissioning of the announcement console/call station with microphone suitable for 36 zones. The unit shall be suitable for expansion of atleast 6 additional zones
Supply,fixing,testing and commissioning 19" Rack mountable music source with FM/CD/USB player complete with interconnective cables & accessories.
Supplying, erecting, testing and commissioning of 2 core shielded cable complete as per specification no. FF-PA/MCC
Supplying and fixing 42U floor mount server rack (Dimension-DxWxH – 800x600x1866 mm) as per specification No. WG-NAS/RAK
Supplying erecting, testing and commissioning of Direct Low Pressure (DLP),automatic electrical cabinet fire suppression system kit comprises of themild steel cylinder, hydraulic tested to 30kg /cm2 to check for leakages & burstpressure above 110kg/cm2. duly hot phosphate & epoxy powder coatedinternally and externally more than 65 microns or painted with 1 coat of primerand 2 coats of red enamel paint all complete. The Cylinder assembly is filled with1kg to 1.13kgs of clean agent gas (FK-5-1-12 UL listed) and pre-pressurized to15/16 Bar having storage & operating temperature range of (-) 17.8 deg.C to54.4deg.C with all important accessories e.g. brass assembly valve with pressuregauge, end of line plug with pressure gauge suitable to connect with providedLinear heat detection tube complete with mounting bracket assembly, requiredsize rubber grommets, plastic loop clamps, pressure switch and caution &cylinder Labels etc.
Supplying erecting, testing and commissioning of Direct Low Pressure (DLP),automatic electrical cabinet fire suppression system kit comprises of themild steel cylinder, hydraulic tested to 30kg/cm2 to check for leakages & burstpressure above 110kg/cm2. duly hot phosphate & epoxy powder coatedinternally and externally more than 65 microns or painted with 1 coat of primerand 2 coats of red enamel paint all complete. The Cylinder assembly is filled with4 kg to 4.54 kgs of clean agent gas (FK-5-1-12 UL listed) and pre-pressurizedto 15/16 Bar having storage & operating temperature range of (-)17.8deg.C to54.4deg.C with all important accessories e.g. brass assembly valve with pressuregauge, end of line plug with pressure gauge suitable to connect with providedLinear heat detection tube, complete with mounting bracket assembly, requiredsize rubber grommets, plastic loop clamps, pressure switch and caution &cylinder Labels etc.
Supplying erecting, testing and commissioning of Direct Low Pressure (DLP),automatic electrical cabinet fire suppression system kit comprises of themild steel cylinder, hydraulic tested to 30kg/cm2 to check for leakages & burstpressure above 110kg/cm2. duly hot phosphate & epoxy powder coatedinternally and externally more than 65 microns or painted with 1 coat of primerand 2 coats of red enamel paint all complete. The Cylinder assembly is filled with2kg to 2.27kgs of clean agent gas (FK-5-1-12 UL listed) and pre-pressurized to15/16 Bar having storage & operating temperature range of (-)17.8deg.C to54.4deg.C with all important accessories e.g. brass assembly valve with pressuregauge, end of line plug with pressure gauge suitable to connect with providedLinear heat detection tube, complete with mounting bracket assembly, requiredsize rubber grommets, plastic loop clamps, pressure switch and caution &cylinder Labels etc.
Supplying and erecting of linear heat detection tube (UL Listed) made fromspecial flexible polymer material having 6 mm outside & 4 mm inside diametersuitable for working pressure of 20 bar having Red RAL 3000 colour withoperating rupture temperature between 110 deg C to 120 deg C or 125 deg C to145 deg C or 170 deg C to 180 deg C. The tube shall be flexible and shall be kinkresistant having minimum bending radius of 100 mm complete erected withnecessary drilling at panel wall entries duly connecting with provided end lineplug fittings, with rubber grommets, plastic loop clips/clamps etc. complete withall accessories
Supplying erecting, testing and commissioning of Master Control Unit (MCU)with 12/24Vdc Audio Visual Alarm with wiring to alert discharge of the DLPsystem suitable to work at 230V AC 50Hz supply with battery backup forminimum 30 minutes in alarm condition, equipped with green LED indicator forhealthy system & red LED indicator for discharged system the MCU suitableprovide outputs for activation of sounders or to third party devices which may beused for notification.
Supplying, installing, testing and commissioning of digital linear heat detectioncable along installation accessories e.g. clips, nails & end cap etc. dulyaddressable through monitor module with temperature ratings such as, 58°-105°C, conforming to IS 2189: 2008, EN 54 or UL listed, as per specification no.FF-AFAS/LHDC.
Providing & erecting of 8 mm Aluminum Round Conductor complete as specified in drawing & Meets the requirements of DIN EN 50164-2 (VDE 0185 part 202) & VDE 0185-305 (IS/IEC 62305) ,
Providing & erecting holder: With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance.
Providing & erecting Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance.
Providing & erecting of cross universal connector: For T and cross connection,to route vertical down conductor /mesh formation made of hot dipped galvanised iron with necessary screws etc as required. Installed with 4 hexagonal bolts M8*25 with M8 hexagonal nuts .
Providing & erecting of expansion piece with connector: For equalisingtemperature related length changes. Necessary on conductorslength over 20 meters. For round conductor Rd 8/ALU.
Providing & erecting of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Conforms to the requirements according to DIN VDE 0185-305 (IS-IEC 62305)(2nos/expansion piece ).
Providing & erecting of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 10 mm aluminium rod :Meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IS/IEC 62305) 4 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load.
Providing & erecting of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and tested upto 100KA lightning current .
Providing & erecting of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and tested upto 100KA lightning current .
Providing & erecting of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 10 mm aluminium rod :Meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IS/IEC 62305)2 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. OBO Type No. 101 VL2000 ( 5401 98 3)
Providing & erecting of 8 mm Aluminum Round Conductor complete as specified in drawing & Meets the requirements of DIN EN 50164-2 (VDE 0185 part 202) & VDE 0185-305 (IS/IEC 62305) ,
Providing & erecting of Galvanised Steel Flat 30X3 mm thickness from earthelectrode directly in ground as required. Flat conductor shall be of Hot Dipped & Cross sectional area of 90mm squareAccording to DIN EN 50164-2 (VDE 0185 part 202) Meets therequirement of VDE0185/305(IS-IEC 62305) Zinc coating: 500 g/m square (Approx :70 micron coating) Should be tested and used exclusively for lightning protection earthing system and ring equipotential bonding.
Providing & erecting of diagonal clamp suitable for FL 30. Installed with 2hexagonal bolts.
Providing & erecting Cross connector for earth fixing point suitable for FL 30. Installed with 2 hexagonal bolts.
Providing & erecting of earth fixing point for connecting Air terminal with earth fixing point
Supply Installation Testing & Commissioning of IP 67 Rated 2 MP Motorised Varifocal lenses Vandal proof Bullet Network camera having 2.8 ~ 12mm (4.3x) motorized varifocal lens, , Min. Illumination: Color : 0.015Lux (F1.4, 1/30sec), B/W : 0Lux (IR LED on), r Field of View: H : 119.5˚ ~ 27.9˚ / V : 62.8˚ ~ 15.7˚ / D : 142.1˚ ~ 32.0˚ , Max. 60fps@all resolutions (H.265),Backlight Compensation: BLC / HLC (Masking / Dimming, Day & Night (ICR), WDR(150dB), Defog, Built in Intelligent Video analytics : Tampering, Loitering, Directional detection, Defocus detection, Fog detection, Virtual line, Enter / Exit, (Dis)Appear, Audio detection, Face detection, Motion detection, Digital auto tracking, Sound classification Loitering, Directional detection, Fog detection , Digital auto tracking, Sound classification, Tampering, Handover, Dual SD slots (Max. 512GB), Hallway view, IR viewable length 50m, IP67/IP66, NEMA 4X, IK10
Supply Installation Testing & Commissioning of IP 67 Rated 5 MP Motorised Varifocal Vandal proof Dome/bullet Network camera having 5megapixel (2560 x 1920) resolution, 3.9 ~ 9.4mm (2.4x) motorized varifocal lens, Max. 30fps@ all resolutions (H.265/H.264), 120 db WDR, 2D+3D DNR, Motion detection, Privacy masking, BLC/HLC, Min. Illumination: Color : 0.07Lux (F1.3, 1/30sec), B/W : 0Lux (IR LED on), H.265, H.264, MJPEG codec supported, Multiple streaming ( 10 profiles ), Day & Night (ICR), WDR (120dB), Defog, Built in Intelligent Video analytics like Loitering, Directional detection, Fog detection, Audio detection, Digital auto tracking, Sound classification, Tampering, Motion detection, Handover between cameras, SDXC memory slot (Max. 512GB), Coridoor view, Smart Stream II support, IR viewable length 50m, IP67, NEMA 4X, IK10, PoE / 24V AC, 12V DC. The camera should have model specific UL,CE,FCC, IP-67, IK-10 & NEMA 4X certifications
SITC of Outdoor Application Low Light IP Hi speed Dome type PTZ camera with 2 MP Resolution, min 6 ~ 222mm lens, Low Light Min. Illumination: Color : 0.05Lux (1/30sec, F1.5) B/W : 0Lux (IR LED on),Day/Night, Wide dynamic range 120 dB,DIS with built-in Gyro sensor, Min. IR viewable length : 350m, H.265 streaming, Auto tracking, Intelligent video analytics , vandal resistant, 360° continuous pan, -0° to +90° tilt, 256 preset, IP66 & IK10 rated Mounted on Wall/Pole as per site requirement & including all required accessories.
Supply Installation Testing & commissioning of 3.5 inch Enterprise 8TB Hard Disks of 7200 RPM with a Sata 6 GBps Interface, 256Mb Cache,600000 load/ Unload cycles,2500000(MTBF), with 5 Year Manufacturers warranty,and with the following poweer management capacities7.1 Sequential read, 6.7- Sequential write, 6.8 -Random read/write, 5.0- Idle
Supply, Installation, Testing and commissioning (SITC) of 65" 4K Ultra Hd Digital professional Displayhaving 500 nits based on a IPS Panel / D-LED panel, having 1783 / 178° Viewing Angle (Horizontal/Vertical), 20W Builtin Speaker, The display shoulld have the following ports HDMI Type A Connector × 1, DisplayPort × 1, DVI-D 24-Pin × 1, Mini D Sub 15-pin × 1, M3 × 1, USB 2.0 × 1, USB 3.0 × 2, Component (YPbPr) x1, AV In x 1, RJ-45 x 1,RS232Cx1 & Video Out x1
Supply, Installation, Testing and commissioning of Custom Mount Fix Stand with tilt vertical -/+ 10 & Horizontal - /+ 15 Mechanisam for 65 LCD/LED TV
Supplying, fixing, and configuring 20 SFP ports + 4 Combo SFP 10/100/1000 Base-T erected in provided rack completee
Syppying installation testing and comissioning of 32 Ch. 4K Network Video Recorder Up to 12MP resolution preview and playback,Max 320Mbps incoming band width, Instastream /H.265 /Smart H.264+/H.264/MJPEG, Support 8 SATA HDDs up to 16TB Each, 4 USB Ports (2 USB3.0), 1 eSATA port, 2 HDMI / 2 VGA simultaneous video output , Support Multi-brand network camera, Support RAID 0/1/5/10, ONVIF Version 2.4 conformance, Mobile Software: iCMOB, gCMOB, CMS Software: KVMS Pro
Supply Installation Testing & commissioning of Network Video Management Software license for 1 camera, shall be comply Virtual Matrix capablity; Maps and alarm management etc. Open Protocol ONVIF Compliant system architecture complete with all necessary licenses etc, minimum as per below : Unlimited Storage License for Site, Minimum 2 Admin and 15 Concurrect User Licences
Supplying, fixing, and configuring Managed L2 Power over Ethernet Switch of 20 Ports + 4G Combo Port as per specification complete. with 5 year onsite warranty
Supplying & installing HDMI cable low voltage grade as per specification as per specifications having 5 mtr cord length with male/female 19pin HDMI connectors as per requirements complete. ft with 5 year onsite warranty
Supplying and fixing 11AC dual-band PoE standalone/software based access point as per specification complete.
Supplying and fixing 42U floor mount rack (DimensionDxWxH – 800x600x1866 mm) as per specification No. WGNAS/RAK
Supplying, installing, testing and commissioning of ETC solar water heating system without heat exchanger type of 500 LPD capacity with SS water tank of 0.5 mm thickness conforming to IS1239 Part-I :2004 complete as per specification no. ESD-SHWS-ETC
Supplying and erecting 32/40 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC), thickness 3.8 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC
Supplying and erecting 25/32 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC), thickness 3.2 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC
Supplying and erecting 20/25 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC), thickness 2.6 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 42 mm for solar water heater/AC system.
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 32 mm for solar water heater/AC system
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 28 mm for solar water heater/AC system.
Providing replacement of existing unserviceable SS water tap of for solar wate heater system by new one of same capacity, testing to the satisfaction of site engineer for cooling and along with guarantee for one year with suitable refrigerant.
Supplying, installing, testing and commissioning of 10 kWp ON-GRID Solar PV System / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 30 Nos.) and Solar ON-GRID Inverter of similar capacity (THD<3%) with interconnecting wires / cables up to solar ON GRID inverter, proper base plate,canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB ,MCB etc. wiring up to solar Inverter in casing and capping, display board, sign board, two distinct earthing, lightning arrester, liaisoning charges, remote monitoring system with maintaining card/chip for 5 years including net charges for RMS System, complete up to net meter installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract as per Specification no. ESD-RT-ONG
Supplying and erecting minimum Three & above star rated 3 phase, 415 V, 50 Hz, submersible pump set of 7.5 KW/10HP suitable for erection on open well, pump having delivery head from 72 to 28 m and discharge from 120 to 840 litres. per minute & pipe of Suction 65 mm/Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP
Supplying & erecting automatic control panel for 3 Ph, 415 volt, A.C. submersible/centrifugal pump set up to 7.5 HP - 10 H.P. consisting of DOL starter having relay range 13-21 AMP,S.P.P., Combined ammeter/voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc.
Supplying & erecting Water level controller 230/415 V, A.C. , Two way under ground tank operation only.
Supplying & erecting directly operated Single phasing preventer complete erected and connected to supply to operate in case of single phasing with guarantee for minimum one year.
Supplying, erecting & marking FPMCB 6A to 32A, with rated short - circuitbreaking capacity (Icn) 10kA in provided distribution board as per specificationno. SW-SWR/MCB
Supplying, fixing and commissioning MCB type change over switch 4 pole, 25A with 3 positions (I-O-II) with centre off position as per specification no. SW-SWR / MCBCOS
Supplying and erecting marine (Waterproof) plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners, supports, nut bolts etc. complete with compliance to IS 720:2010
Load Survey, Site preparation, design, supply, installation and testing commissioning of air cooled 3 Phase 15 KVA 20 A/phase IOT based Smart Optimizer devices with in-built solid state stabilizer & SPD, wall mounting system not extending more than 180mm from the wall, length not extending more than 550 mm & height not extending more than 600 mm, with supply of reliable wifi network near the system for pre diagnosis of critical electrical events with automated notifications and automating the critical tasks of electrical safety monitoring and management, automatic voltage optimization, cloud based storage and retrieval of 20 types of electrical issues viz. risk of arcing, short circuit, over current, earth leakage, earth to neutral voltage, over voltage, under voltage, surge, phase loss, phase reversal, loss of supply to neutral, voltage harmonics, voltage variation, voltage unbalance, current harmonics, loads with low power factor, loads with high harmonics, loads with high inrush, unbalanced or asymmetric loads, short term interruptions of supply, reverse current, meeting the mandate of IOT based automated real-time smart audits, in addition over the air configurable optional automatic isolation for 12 types of electrical events, with backlit LCD display, measuring parameters in electrical safety, power quality, energy efficiency audits and display voltage, current, kW, kVA, PF, earth voltage, earth leakage current for 3 phase 4 wire system complete with internal wiring connections and mounting hardware for provided Smart Optimizer devices along with Remote monitoring and Proactive command centre support for one year that will call electrician to guide them on correction of Faults and Warnings based on a root cause analysis and criticality level and Comprehensive Maitenance Contract (CMC) of Smart Optimizer devices for first year. (NCSR approved by SE, MREC vide letter no.1154, Dt.28.12.2021, Sr.no.284/2021-22)
Supplying, erecting & terminating FRLS-XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU. (Base Note6 - For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rate by 2 %)
Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW ( Note 3- Rates of earth wire shall be calculated as one half rate of mains of bunch of two wire)
Load Survey, Site preparation, design, supply, installation testing and commissioning of air cooled 3 Phase 30KVA: 40 A/phase 1OT based Smart Optimizer devices with in-built solid state stabilizer & SPD, wall mounting system not extending more than 180mm from the wall, length not extending more than 650 mm & height not extending more than 700 mm, with supply of reliable wifi network near the system for pre diagnosis of critical electrical events with automated notifications and automating the critical tasks of electrical safety monitoring and management, automatic voltage optimization, cloud based storage and retrieval of 20 types of electrical issues viz. risk of arcing, short circuit, over current, earth leakage, earth to neutral voltage, over voltage, under voltage, surge phase loss, phase reversal, loss of supply to neutral, voltage harmonics, voltage variation, voltage unbalance, current harmonics, loads with low power factor, loads with high harmonics, loads with high inrush, unbalanced or asymmetric loads, short term interruptions ofsupply, reverse current, meeting the mandate of IOT based automated realtime smart audits, in addition over the air configurable optional automatic isolation for 12 types of electrical events, with backlit LCD display, measuring parameters in electrical safety, power quality, energy efficiency audits and display voltage, current, kW, kVA, PF, earth voltage, earth leakage current for 3 phase 4 wire system complete with internal wiring connections and mounting hardware for provided Smart Optimizer devices along with Remote monitoring and Proactive command centre support for one year that will call electrician to guide them on correction of Faults and Warnings based on a root cause analysis and criticality level and Comprehensive Maintenance Contract (CMC) of Smart Optimizer devices for first year. (NCSR approved by SE, MREC vide letter no.1154, Dt.28.12.2021, Sr.no.284/2021-22)
Supplying, erecting & terminating FRLS-XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU. (Base Note6 - For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rate by 2 %)
Supplying, Erecting & Configuring 4G wireless Dongle datacard for Wifi Hotspot with Min. 4 Hrs. battery backup with Sim-Card and Sim-card slot supporting all networks duly connected with electric supply flexible cord of min. 1 m length and in-built power adapter to provided plug point duly erected in suitable PVC box complete. (NCSR)
Basic Test of Cement : Standard Consistancy, Fineness, Specific Gravity, Setting Time ( Initial & Final ), Compressive Strength, Soundness.
Basic Test of Agreegate : Water Absorption, Specific Gravity,Impact Value, Crushing Value.
Basic Test of Agreegate : Sieve Analysis.
Basic Test of Agreegate : Flakiness Index & Elongation Index.
Basic Test of Fine Agreegate :Fineness Modulus ( Sieve Analysis ),Silt & Clay Content
Basic Test of Fine Agreegate :Chloride & Sulphate Content.
Basic Test of Fine Agreegate :Silt Factor.
Basic Test of AAC BLOCKS : Density Test . (Set of 3 Blocks ),Compressive Strength. (Set of 3 Blocks ),Water Absorption Test ( Set of 3 Blocks )
Basic Test of Concrete : Compressive Strength of C.C. Cube (Set of 3 cubes).
Basic Test of Concrete : Concrete Mix Design (With all Tests on basic materials)
Basic Test of Concrete : Flexural strength of Beam.
Basic Test of Concrete : Permeability Test.
Basic Test of Concrete : Concrete mix design by Accelerated curing method. (By Accelerated curing method)
Basic Test of Mortar :Compressive Strength.( Set of 3 Cubes)
Basic Test of Stone/ Rubble : Crushing Value/Compressive Strength, Water Absorption & Specific Gravity,
Basic Test of Murrum : Sieve Analysis.
Basic Test of Murrum : Liquid limit & plastic Limit.
Basic Test of Murrum : Compaction Test ( Proctor Density ).
Basic Test of Water : PH Value, Sulphate & Chloride Content.
Basic Test of Wood : Density, Moisture Content.
Basic Test of Flush Door : Knife Test, Adhesion Test, End Immersion Test.
Basic Test of PVC pipes :Weight per running meter,Diameter of pipe & wall thickness of pipe
Basic Test of Steel Bar : (Tensile strength, %, Elongation, Yield Stress,Weight-Per Meter, Bend / Rebend Test, Proof Stress.) Upto 16 mm (Set of 3 Bars)
Basic Test of Steel Bar : (Tensile strength, %, Elongation, Yield Stress,Weight-Per Meter, Bend / Rebend Test, Proof Stress.) Above 16 mm (Set of 3 Bars)
Royalty Charges for Other Minerals (Murum & Rubble) are to be paid to the contractor after producing receipt of royalty paid to the Govt. for the material used for this work.
Royalty Charges for Sand are to be paid to the contractor after producing receipt of royalty paid to the Govt. for the material used for this work.
NIRMITI BUILDCOM
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid