Loading…
Loading…
Tender Value
₹55.5 L
EMD Value
₹1.1 L
Closing Date
18 Dec 2025, 1:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
TECHNICAL
15 conditions · 4 needing a document upload
Clause Regarding GST: (a) All the Bidders/tenderers should ensure that they are GST Compliant and their quoted tax Structure are as per GST LAW.(b) Tenderer Should Furnish their GSTIN numbers representing the States in Which they are registered GST, along with address of Registered Office.(c)The Contract is under GST Act and rules as applicable time to time.
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. Annual Contractual Turnover Data for the Previous 3/4 Years should be submitted as per Annexure-IX.(Annexure- VIB of Tender Documents).
40 conditions · 11 needing a document upload
Check List: The tenderer(s) would fill up the check list, as per Annexure-XXIII to ensure that they are submitting the complete tender offer.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Provision of PP Shed (DBRG,TSK,MJN,LLO,MRG,NTSK & DJG) ( Total -30 Bays)
LV-T-14-TSK-920~NFR
LV-T-14-TSK-920
Open
Works - General
12 Months
Tinsukia, Assam
₹0
₹1.1 L
18 Dec 2025
26 Nov 2025
4 Dec 2025
39 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 55,45,517 | ||
| — | 700.00 | — | — | ||
| Supply, connection , testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable size 70 mm.sq. 4 core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988. For laying of above by excavation of earth depth 0.75 Mtrs. into breadth 0.508 Mtrs. below the ground level and a layer of course sand of 7.5 CM thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of course sand of 7.5 CM thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. Above the Layer of Course Sand 3 inch Size Brick is to be provided for protection of cable. Cable route markers to be provided at an interval not less than 50 Mtrs. All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024. | — | — | — | 6,73,400 | |
| — | 1500.00 | — | — | ||
| Supply, laying, connection, testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable size 25 mm.sq. 4 core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988. For laying of above by excavation of earth depth 0.75 Mtrs. into breadth 0.508 Mtrs. below the ground level and a layer of course sand of 7.5 CM thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of course sand of 7.5 CM thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. Above the Layer of Course Sand 3 inch Size Brick is to be provided for protection of cable. Cable route markers to be provided at an interval not less than 50 Mtrs. All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024. | — | — | — | 7,27,500 | |
| — | 1500.00 | — | — | ||
| Supply, laying, connection, testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable size 16 mm.sq. 2 core having Glavanised Wire Solid Aluminum Conductor, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988. For laying of above by excavation of earth depth 0.75 Mtrs. into breadth 0.508 Mtrs. below the ground level and a layer of course sand of 7.5 CM thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of course sand of 7.5 CM thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. Above the Layer of Course Sand 3 inch Size Brick is to be provided for protection of cable. Cable route markers to be provided at an interval not less than 50 Mtrs. All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024. | — | — | — | 4,86,000 | |
| — | 500.00 | — | — | ||
| Supplying and laying of size 63 mm dia (OD-63 mm & ID-51 mm nominal) DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. | — | — | — | 1,23,500 | |
| — | 300.00 | — | — | ||
| Supply fitting fixing of Surface /Suspended and wall mounted IP 65 LED batten 40 Watt , CRCA housing provided for efficient heat dissipation with polycarbonate diffuser & built-In electronic driver with THD<10% & Lumen efficacy >=115 lm/W. LED Should be as per LM- 80/IS:16105, Driver: Integral electronic driver (SMPS based constant current supply) with Output Short-circuit protection, Surge protection & other safety tests as per IS:15885 Part 2/Sec 13. Operating Voltage: 140-270V AC.Length Of fixture: 1213x30x36 mm(LxWxH), | — | — | — | 7,72,500 | |
| — | 1500.00 | — | — | ||
| Supply, laying,connection, testing and commissioning of single core 1.5 Sq. mm PVC insulated & unsheathed multistrand FRLSH copper cable, 1100 Volts, conforming to IS: 694. | — | — | — | 33,345 | |
| — | 3900.00 | — | — | ||
| Supply, laying,connection, testing and commissioning of single core 2.5 Sq. mm PVC insulated & unsheathed multistrand FRLSH copper cable, 1100 Volts, conforming to IS: 694. | — | — | — | 1,51,320 | |
| — | 3600.00 | — | — | ||
| Supply, laying,connection, testing and commissioning of single core 4.0 Sq. mm PVC insulated & unsheathed multistrand copper FRLSH copper cable, 1100 Volts, conforming to IS: 694. | — | — | — | 2,04,120 | |
| — | 3000.00 | — | — | ||
| Supply, laying,connection, testing and commissioning of single core 6.0 Sq. mm PVC insulated & unsheathed multistrand copper FRLSH copper cable, 1100 Volts, conforming to IS: 694. | — | — | — | 2,55,000 | |
| — | 650.00 | — | — | ||
| Supplying and installing of perforated 150 mm width X 50 mm depth X 1.6 mm thickness,Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/PP shed with G.I. suspenders including G.I. bolts & nuts, etc. as required. Provision of Cable tray Bends, Tees, Cross member included in the scope of work. | — | — | — | 4,65,400 | |
| — | 500.00 | — | — | ||
| Supply, fitting, fixing of 25 mm dia Rigid MMS PVC heavy duty conduit pipe with accessories(Elbow,TEE,Bend etc) conforming to IS :9537 Part-III-1983 and IS: 3419-1988. | — | — | — | 29,500 | |
| — | 14.00 | — | — | ||
| Supply, fitting, fixing of 200 Amps outdoor type cable junction box, angle frame mounted, dust & vermin proof, complete with rain cap, aluminium basbar of suitable size for TPN, 200 Amps, 415 V made out of 16 SWG CRCA sheet duly painted, Cable Junction Box Size: (lxbxh=450x 450x600 mm). The base of the fedder pillar junction box to be provided with CC foundation of propotion 1:1.5:3( cement, sang,Chips) after connection of Ug cables. | — | — | — | 1,25,146 | |
| — | 240.00 | — | — | ||
| Supply, fitting & Fixing of thermoplastic cable junction boxes IP66/IP67 "weather proof" for outdoor installations with knockouts for cable entry suitable for cable size 2.5-6 Sq. mm with Terminals for cable connection. | — | — | — | 3,69,600 | |
| — | 26.00 | — | — | ||
| Dismantalling of Tubular Poles/Rail Poles including all accesories and deposition of the released material to concerned Railway Power house. | — | — | — | 69,212 | |
| — | 60.00 | — | — | ||
| Supply , fitting, fixing of Air circulator Fan 600 mm sweep on PP shed Column with necessary fixing arrangement and connection with 1.5 Sq. mm single core FRLS copper cable through PVC flexible pipe 20 mm dia and as per direction of Engineer Incharge at site. | — | — | — | 4,72,860 | |
| — | 21.00 | — | — | ||
| Earthing by 50 mm dia, 3.6 mm thickness 3 Mtrs long GI pipe and 6 SWG GI wire,GI nuts,bolts including masonary materials for earthing pit,salt,charcoal etc. and construction of earth pit covered with CI plate having locking arrangement and watering pipe as per Drawing No PCEE/ELG/DRG/2024/1 Dtd 30.09.2024 | — | — | — | 91,434 | |
| — | 60.00 | — | — | ||
| Supply, Fitting, fxing of Mobile Charging Points With 4 Nos of Modular Switch, Socket, 12M Plastic Surface Box, 12 M Cover plate, 1.5 Sq mm single core copper cable, PVC pipe as required and Suitable Size Tray(Stainless Steel). The Mobile Charging Board to be properly fixed on PP shed column with necessary arrangement as per direction of Engineer Incharge at Site. | — | — | — | 86,040 | |
| — | 3.00 | — | — | ||
| Supply, installation of pure sine wave inverter 2.5KVA/2 KW , 24V DC with inbuilt LCD display, Protection: Short circuit, Overload, Over Temperature, Low Battery Alarm , MCB protection for input mains,Adaptive Battery charging control system,reverse polarity protection along with Battery bank consisting of 2 Nos 150Ah, 12V Tall tubular lead acid battery. Warranty: Inverter: 24 Months, Battery: 36 Months.(18 Months Free of Cost+18 Months Pro-rata) for PP Shed Energency Lighting(MJN ,MRG & DJG ) | — | — | — | 1,88,370 | |
| — | 7.00 | — | — | ||
| Supply, fitting, fixing of wall mounted VTPN DB, Horizontal TP MCCB as incomer 4 way double door , IP: 43 Protection, Shrounded Neutral Bar and pan assembly with flexible connecting link., cement spill protector, door earthing with the following:(i) MCCB 100 Amps, TPN ,25KA BC= 1 No.(ii) MCB SP 63 Amps, C series, Icn =10KA BC= 6 Nos. | — | — | — | 2,21,270 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .