Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹15.4 LAccepted-AOC THIS INFORMATION IS NOT AVAILABLE IN THE PROVIDED DOCUMENT | KAMRUP METRO | ASSAM | 781005 | L-1 | Accepted-AOC RATES ARE FOUND REASONABLE AND THE FIRM BEING L1 BIDDER | |
| 2 | L-2₹16.4 L+₹70,605.88 (4.50%)Rejected-Finance | L-2 | Rejected-Finance BEING L2 BIDDER | |
| 3 | L-3₹16.5 L+₹78,933.75 (5.03%)Rejected-Finance RANGIYA STATION ROAD WARD NO 2 PO RANGIYA DIST KAMRUP ASSAM PIN 781365 | BAKSA | ASSAM | 781365 | L-3 | Rejected-Finance BEING L-3 BIDDER | |
| 4 | L-4₹16.7 L+₹99,547.75 (6.34%)Rejected-Finance OLD MISSAMARI PO PS MISSAMARI DISTT SONITPUR ASSAM PIN 784506 | SONITPUR | ASSAM | 784506 | L-4 | Rejected-Finance BEING L-4 BIDDER | |
| 5 | L-5₹17.3 L+₹1.6 L (10.0%)Rejected-Finance C O DR UMASHANKAR SHARMA RANGIYA TINIALI NEAR RAIL GATE POST RANGIYA DIST KAMRUP ASSAM PIN 781354 | KAMRUP | ASSAM | 781354 | L-5 | Rejected-Finance BEING L-5 BIDDER |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
5 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Rangia
GE Rangia C/O 99 APO Rangia
REPAIR TO CERTAIN B/R WORKS IN MES INSTALLATIONS AT HATTIGOR MIL STN UNDER GE RANGIA
2023_MES_617438_1
8712/E8
Open Tender
Civil Works
Item Rate
180 days
Hattigor
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE Rangia
₹40,000
Yes
26 Oct 2023
6 Sept 2023
7 Oct 2023
6 Sept 2023
5 Oct 2023
23 Sept 2023
6 Sept 2023 - 13 Sept 2023
Amount
S&F of mild steel posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165, complete all as specified and as directed by Engineer-in-charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and as directed by Engineer-in-charge.
Dismantling posts or struts (wood, steel or R.C.C.) of any section, embedded in concrete including taking out embedded portion and making good disturbed ground, complete all as specified and as directed by Engineer-in-charge.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc., complete all as specified and as directed by Engineer-in-charge.
M&L for PCC 1:3:6 type C-2 (40mm graded stone aggregate) as in foundations, fillings and mass concrete complete all as per specified and as directed by Engineer-in-charge.
M&L for Providing Cement Concrete 1:2:4, type B-1 (20mm graded aggregate) as in Coping, edging, benching, etc. and finishing the Concrete surfaces even and smooth without using extra cement, including necessary Formwork required at Site(s), demolition of existing old unserviceable concrete, complete all as specified and as directed by Engineer-in-charge.
M&L for Providing cement concrete 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) in levelling course, roof kerbs or mud stops, rounded or chamfered on edges including necessary formwork, complete all as specified and as directed by Engineer-in-charge.
M&L for Reinforced Cement Concrete, (Nominal Mix) 1:2:4, type B-1 (20mm graded stone aggregate) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, including demolition of existing old unserviceable RCC of any type, complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement & Formwork will be measured and paid separately under relevant Item.
M&L for Reinforced Cement Concrete, (Nominal Mix) 1:2:4, type B-1 (20mm graded stone aggregate) in Columns, pillars, piers, posts and struts, including demolition of existing old unserviceable RCC of any type, complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement & Formwork will be measured and paid separately under relevant Item.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, rough finished flat surfaces of concrete, complete all as specified and as directed by Engineer-in-charge.
M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions, rough finished flat surfaces of concrete, complete all as specified and as directed by Engineer-in-charge.
S&F of TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed by Engineer-in-charge.
S&F of TMT bars 6-8mm dia, cut to length, bent to shape required, in stirrups, spacers and binders and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed by Engineer-in-charge.
S&F of mild steel Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing, confirming to Fe 410-W (Gde- E- 250) quality-A, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of 0.63 mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required, complete all as specified and as directed by Engineer-in-charge.
M&L for Brickwork with Fly ash bricks, straight or curved on plan to any radius built and set in cement mortar 1:6, incl demolition of existing B/W,complete all as per specified and as directed by Engineer-in-charge.
M&L for Brick work in lining in drains laid flat, with sub class 'B' bricks, Bedded and jointed in CM 1:6 and pointed in CM 1:3, incl demolition of existing B/W, complete all as specified and directed by Engineer-in-charge.
S&F of 11-15 mm dia Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 5cm but n exc 10cm long, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and including provision of galvanised mild steel wire, staples or steel pins, etc.(each line wire to be measured), complete all as specified and as directed by Engineer-in-charge. NOTE: Cost of GI Binding Wire shall deem to be included in the quoted Unit Rate.
Restraining, resecuring of Galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings fixing to any type of standard rails straining bolts, tying at crossings with and including provision of galvanised mild steel wire, staples or steel pins, etc.(each line wire to be measured), complete all as specified and as directed by Engineer-in-charge. NOTE: Cost of GI Binding Wire shall deem to be included in the quoted Unit Rate.
S&F in-repair of PVC coated Chain Link Fencing of 4mm dia GI wire of 100x100mm Mesh to any type of standards, rails, straining bolts, etc. including provission of binding wire, PVC Coated Final Diameter shall not be less than 5.0mm, complete all as specified and as directed by Engineer-in-charge. NOTE: Cost of GI Binding Wire shall deem to be included in the quoted Unit Rate.
S&F in-repair of mild steel Tie bars cut to length, bent to shape required, including cranking, bending as in stiffner to chain link fencing, conforming to Fe- 290 Gde-E-165, complete all as specified and as directed by Engineer-in-charge.
M&L for providing glossy finished PU coated Chequered cement concrete coloured tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors., laid over 20mm thick cement screed 1:6 with grey cement and pigments to match, including dismantling the existing old unserviceable tiles of any type and of any description, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing 40 mm thick Cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) as in floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces even and smooth with using extra cement and demolition of existing old unserviceable concrete, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing 38mm wide glass dividing strips, 3mm thick, inserted in position, conform to design, complete all as specified and as directed by Engineer-in-charge.
M&L for providing 75 mm thick Cement concrete type C-2, 1:3:6 (40mm graded stone aggregate) as in floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces even and smooth with using extra cement and demolition of existing old unserviceable concrete, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing matt-finished/ stone finished ceramic coloured tiles in vertical surface (like skirting, dado, etc.) 450x 300x 7-8 mm thick, over 10mm thick cement screed 1:3 set and jointed in neat cement slurry and pointed in white or colour cement to match, including dismantling the existing old unserviceable tiles of any type and of any description, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing Non-skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc., laid over 20mm thick cement screed 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match, including dismantling the existing old unserviceable tiles of any type and of any description, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing 100 mm thick Cement concrete type D-2, 1:4:8 (40mm graded stone aggregate) as in sub-base of floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces even and fair, including demolition of the exisiting old PCC, complete all as per specified and as directed by Engineer-in-charge.
M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; including dismantling of old disturbed unserviceable paver blocks, complete all as per specified and as directed by Engineer-in-charge.
M&L for preparing newly plastered surfaces of ceiling and applying three coats of white wash, complete all as specified and as directed by Engineer-in-charge.
M&L for preparing newly plastered surfaces of wall and applying two coats of cement base paint of any shade over a coat of alkali-resistant priming paint, complete all as specified and as directed by Engineer-in-charge.
M&L for preparing newly plastered surfaces of wall and applying two coats of distemper oil emulsion of any shade over a coat of chalk whitening, complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of new or previously un-treated steel/iron surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of Synthetic enamel paint (1st quality) of any tint over a coat of red oxide primer, complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of new or previously un-treated steel/iron surfaces of any description, n.exc 10cm in width or girth when unconnected with other painting or when painted in a different tint and applying two coats of Synthetic enamel paint (1st quality) of any tint over a coat of red oxide primer, complete all as specified and as directed by Engineer-in-charge.
M&L for Rendering 10mm thick in cement morter 1:6 on the ‘other’ side of lathing or other than fair faces of brick work/ concrete surfaces, finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-in-charge.
M&L for Rendering 15mm thick in cement morter 1:4 on fair faces of brick work or concrete surfaces or one side of lathing, finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-in-charge.
M&L for Rendering 10mm thick in cement morter 1:3 on ceiling surface, finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of concrete roof surfaces by removing old layer of membrane and morter bed, scrapping and cleaning the surfaces to carry out the roof treatment works by the following process:- (a) Rendering 15mm thick in cement morter 1:4 on fair faces of concrete surfaces, mixed with WPC as per Manufactures instruction, finished even and fair. (b) Applying a coat of bitumen 85/25 @ 1.20 Kg per Sq. m. over a coat of bitumen primer @ 0.30 kg per sq. m. (c) Applying APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application, complete all as specified and as directed by Engineer-in-charge.
Supply only Liquid Integral waterproofing compound, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of powder coated (minimum thickness of powder coating 50 micron) Anodised aluminium window and ventilator shutters, side hung type without sash bars, with and including aluminium sections 65x38x1.48mm for frame, 44x38x1.98mm for shutter including necessary joining cleats, 5mm thick tined glass fixed with glazing clips, rubber packing, powder coated anodised aluminium snap beading, screws, powder coated anodised aluminium fittings such as peg stays 150mm long (1 no.) hinges type B-21 100mm long (2 no.) suitable handle (1 no.), complete all as specified and as directed by Engineer-in-charge.
M&L for PCC 1:4:8 type D-2 (40mm graded stone aggregate) as in foundations, fillings and mass concrete complete all as per specified and as directed by Engineer-in-charge.
MS Gautam Construction and CO
M/s SHARMA BUILDERS & ENGINEERS
M/S TANISHQ CONSTRUCTIONS
M/S S.S. Construction
Shiva Builders
SWASTIKA TELESERVICES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .