| 1 | L1₹312.27Accepted-AOC 331 TOWER A SPAZE I TECH PARK SECTOR 49 SOHNA ROAD GURGAON 122002 | GURGAON | GURGAON | HARYANA | 122002 | ₹312.27 Quoted ₹2.4 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹2.5 CrRejected-Finance | ₹2.5 Cr | L2 | Rejected-Finance L2 |
| 3 | L3₹2.7 CrRejected-Finance | ₹2.7 Cr | L3 | Rejected-Finance L3 |
| 4 | Not Admitted-Fee/PreQual/Technical PLOT NO F28 COMPLETE COOLING SOLUTIONS LLP PHASE 8 INDUSTRIAL AREA SAS NAGAR MOHALI PUNJAB 160055 UDYAM PB 20 0004625 | S A S NAGAR | PUNJAB | 160055 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | UTILITY SERVICES L1 | AIR WAVES ENGINEERS PVT. LTD. L3 | S G TECHNOFAB PVT LTD L2 |
|---|---|---|---|---|---|---|
| 1.00 | OUTDOOR UNIT Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The ODU shall have low noise condenser fans with extrenal static pressure of the outdoor unit shall be more then 75 Pa to avoid hot air recirculation, auto address setting, auto check function for connection error and complete with indoor and outdoor units with individual controller and with fittings etc. The compressor and VRV/VRF Outdoor make should be same. For enhanced energy savings the COP of each refrigerant circuit system mentioned below shall be 7.10 minimum at 50% load, at AHRI Condition in cooling mode.The unit shall also have feature to automatically modulate the evaporative temperature between 6 deg C to 11 deg C with respect to load for better comfort and energy efficiency. The Unit should have free phase technology so that unit can work in case of phase reversal also without tripping of units. (Heat Pump) 8 HP | 1 | Each | 2,24,961 ₹2,24,961 | 1,65,891 ₹1,65,891 Lowest | 2,45,092.75 ₹2,45,092.75 |
| 4.00 | 12 HP | 2 | Each | 2,50,676 ₹5,01,352 | 2,17,285 ₹4,34,570 Lowest | 2,73,250 ₹5,46,500 |
| 5.00 | 16 HP | 1 | Each | 4,01,020 ₹4,01,020 Lowest | 6,36,178 ₹6,36,178 | 4,10,163.15 ₹4,10,163.15 |
| 6.00 | 20 HP | 16 | Each | 4,01,020 ₹64,16,320 Lowest | 7,70,351 ₹1,23,25,616 | 4,10,163.15 ₹65,62,610.4 |
| 7.00 | Anti Corrosion Treatment | 20 | Each | 9,013 ₹1,80,260 | 2,600 ₹52,000 Lowest | 5,000 ₹1,00,000 |
| 8.00 | FLOOR MOUNTED AIR HANDLING UNITS Supply, Installation, Testing & Commissioning of factory fabricated Indoor Type Double Skinned air-handling unit horizontal type with fabricated out of extruded aluminium (1.6 mm thickness min.)section with Mixing Chamber included Fresh air damper with 0.8 mm thick precoated galvanised sheet outside & 0.8 mm thick 180 GSM Galvanised Steel sheet inside with Backward curved belt driven type Metallic construction in supply with fan section with fan motor with IE3 rating & suitable for 415+10%, 3 Phase, 50 Hz , 4RD/6RD cooling coil with coil section, prefilter (EU-4) section with non woven synthetic washable media of 10µ (micron) particle size with an efficiency of 90% and combined with fine filter ( EU-7 / F7 ) / MERV-13 section with Synthetic fibre media with frame material made out by Aluminium anodized with flange rigid media with efficiency 99 % at 3µ (micron) before cooling coil. The polished stainless steel drain pan of 1.25 mm thick duly insulated with 13 mm thick nitrile rubber under cooling coil shall be provided. Motor & belt drive package/ direct driven arrangement, belt guard etc for belt driven blower without face and bypass dampers. The AHU panel shall be insulated with 43mm thick injected fire retardent PUF of density 38+/-2 Kg/m³ . The motor & fan assembly shall be mounted on aluminium extruded section .Marine light with limit switch shall be provided . The complete AHU shall conform to standard spec.The face velocity across cooling / heating coil, filters should other specifications as per DNIT in PDF. 11000 CFM / 65 mmwg St. Pressure - For Audi seating area | 8 | Each | 5,04,233 ₹40,33,864 | 3,62,960 ₹29,03,680 Lowest | 6,74,250 ₹53,94,000 |
| 9.00 | Anti Corrosion Treatment | 8 | Each | 18,026 ₹1,44,208 | 2,600 ₹20,800 Lowest | 6,250 ₹50,000 |
| 10.00 | Corded Remote | 16 | Each | 3,009 ₹48,144 | 2,339 ₹37,424 Lowest | 3,046.25 ₹48,740 |
| 11.00 | Supply, installation, testing and commissioning of following minimum capacity ceiling mounted Round Flow Cassette type units for VRV / VRF Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, necessary supports, vibration isolation. suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 2.08 TR +- 5% | 5 | Each | 31,175 ₹1,55,875 | 29,880 ₹1,49,400 | 28,423 ₹1,42,115 Lowest |
| 12.00 | 2.64 TR TR +- 5% | 1 | Each | 33,355 ₹33,355 | 33,656 ₹33,656 | 29,609.31 ₹29,609.31 Lowest |
Tender Value
₹3.1 Cr
EMD Value
₹6.2 L
Closing Date
6 Feb 2026, 9:00 amClosed
NAVIN KUMAR
ED - Gurgaon
PDG. HVAC (VRV) AIR CONDITIONING SYSTEM IN MULTIPURPOSE HALL CUM INDOOR STADIUM AT PALWAL(RECALL)
2026_HRY_499996_1
20266E18C4F5 8DB8 46B6 9A60 A115B4AEE7E0664BAR
Open Tender
Civil Works
Works
60 days
Palwal
2 documents required · 2 mandatory
₹15,000
₹6.2 L
Yes
9 Mar 2026
31 Jan 2026
6 Feb 2026
31 Jan 2026
6 Feb 2026
31 Jan 2026
31 Jan 2026 - 1 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | OUTDOOR UNIT Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The ODU shall have low noise condenser fans with extrenal static pressure of the outdoor unit shall be more then 75 Pa to avoid hot air recirculation, auto address setting, auto check function for connection error and complete with indoor and outdoor units with individual controller and with fittings etc. The compressor and VRV/VRF Outdoor make should be same. For enhanced energy savings the COP of each refrigerant circuit system mentioned below shall be 7.10 minimum at 50% load, at AHRI Condition in cooling mode.The unit shall also have feature to automatically modulate the evaporative temperature between 6 deg C to 11 deg C with respect to load for better comfort and energy efficiency. The Unit should have free phase technology so that unit can work in case of phase reversal also without tripping of units. (Heat Pump) 8 HP | 1 | Each | 100 | ₹100 |
| 4 | 12 HP | 2 | Each | 100 | ₹200 |
| 5 | 16 HP | 1 | Each | 101 | ₹101 |
| 6 | 20 HP | 16 | Each | 100 | ₹1,600 |
| 7 | Anti Corrosion Treatment | 20 | Each | 101 | ₹2,020 |
| 8 | FLOOR MOUNTED AIR HANDLING UNITS Supply, Installation, Testing & Commissioning of factory fabricated Indoor Type Double Skinned air-handling unit horizontal type with fabricated out of extruded aluminium (1.6 mm thickness min.)section with Mixing Chamber included Fresh air damper with 0.8 mm thick precoated galvanised sheet outside & 0.8 mm thick 180 GSM Galvanised Steel sheet inside with Backward curved belt driven type Metallic construction in supply with fan section with fan motor with IE3 rating & suitable for 415+10%, 3 Phase, 50 Hz , 4RD/6RD cooling coil with coil section, prefilter (EU-4) section with non woven synthetic washable media of 10µ (micron) particle size with an efficiency of 90% and combined with fine filter ( EU-7 / F7 ) / MERV-13 section with Synthetic fibre media with frame material made out by Aluminium anodized with flange rigid media with efficiency 99 % at 3µ (micron) before cooling coil. The polished stainless steel drain pan of 1.25 mm thick duly insulated with 13 mm thick nitrile rubber under cooling coil shall be provided. Motor & belt drive package/ direct driven arrangement, belt guard etc for belt driven blower without face and bypass dampers. The AHU panel shall be insulated with 43mm thick injected fire retardent PUF of density 38+/-2 Kg/m³ . The motor & fan assembly shall be mounted on aluminium extruded section .Marine light with limit switch shall be provided . The complete AHU shall conform to standard spec.The face velocity across cooling / heating coil, filters should other specifications as per DNIT in PDF. 11000 CFM / 65 mmwg St. Pressure - For Audi seating area | 8 | Each | 104 | ₹832 |
| 9 | Anti Corrosion Treatment | 8 | Each | 105 | ₹840 |
| 10 | Corded Remote | 16 | Each | 107 | ₹1,712 |
| 11 | Supply, installation, testing and commissioning of following minimum capacity ceiling mounted Round Flow Cassette type units for VRV / VRF Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, necessary supports, vibration isolation. suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 2.08 TR +- 5% | 5 | Each | 108 | ₹540 |
| 12 | 2.64 TR TR +- 5% | 1 | Each | 107 | ₹107 |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.25 MB
BOQ_578596.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].