Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.3 LAccepted-AOC | ₹44.3 L Quoted ₹45.0 L | L1 | Accepted-AOC Being a lowest bidder |
| 2 | L2₹48.4 L+₹3.4 L (7.61%)Rejected-Finance NO 14 M C RAJA STREET MITTANAMALLI I A F AVADI CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | ₹48.4 L+₹3.4 L (7.61%) | L2 | Rejected-Finance Being L2 |
| 3 | L3₹57.4 L+₹12.4 L (27.5%)Rejected-Finance NO 42 SIVAN STREET SRI VENKATESAPERUMAL NAGAR VALASARAVAKKAM CHENNAI 600087 | CHENNAI | CHENNAI | TAMIL NADU | 600087 | ₹57.4 L+₹12.4 L (27.5%) | L3 | Rejected-Finance Being L3 |
| 4 | Rejected-Technical | - | - | Rejected-Technical Since not enlisted for appropriate class |
| 5 | Rejected-Technical 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400 708 | THANE | MAHARASHTRA | 400708 | - | - | Rejected-Technical Since not enlisted for appropriate class |
| Sl No | Description | Qty | Unit | SWIFTTECH ENGINEERS INDIA PVT LIMITED L3 | SAMYDOSS CONSTRUCTIONS L2 | M/s Omm Muruga Enterprises L1 |
|---|---|---|---|---|---|---|
| 1.00B/R PORTION: | ||||||
| 1.01 | M&L for cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling the cracks with a hot mixture of bitumen and clean dry sand 1:1 (by weight) complete all as specified. | 75 | Rm | 120 ₹9,000 | 100 ₹7,500 | 99 ₹7,425 Lowest |
| 2.00 | M&L for cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified. | 120 | Rm | 75 ₹9,000 | 100 ₹12,000 | 59 ₹7,080 Lowest |
| 3.00 | Taking out shrubs / vegetation / tree growth from building at any height & any location and applying a Glyphosate pesticide or any other equivalent pesticide in a 10ml of solution mixed with one litre of water and apply on roots using spray gun including taking down cement plaster not exc 0.50 sqm for each tree and making good surface by plastering the same area with 20mm thick plastering in cement mortar 1:4mixed with and including WPC and finishing the surface to match with existing surface including necessary scaffolding and T&P as required at site complete all as specified and directed by Engineer-in- Charge. | 50 | Each | 500 ₹25,000 | 200 ₹10,000 Lowest | 200 ₹10,000 Lowest |
| 4.00 | Demolition of cement conctrete (un-reinfoeced) of any description and in any position not otherwise specifically provided | 13.6 | Cum | 1,200 ₹16,320 | 500 ₹6,800 Lowest | 603 ₹8,200.8 |
| 5.00 | M&L for 40mm thick plain cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in padding concrete mixed with water proofing compound and finished even and fair complete all as specified and as directed.
Note : Water proofing compound shall be measured and paid separately under relevant item. | 240 | Sqm | 1,000 ₹2,40,000 | 300 ₹72,000 | 220 ₹52,800 Lowest |
| 6.00 | M&L for screed bed 15 mm thick in cement mortar 1:4 mixed with water proofing compound as per Manufacturer's instructions for laying APP membrane complete all as specified and directed.
Note : Water proofing compound shall be measured and paid separately under relevant item. | 240 | Sqm | 210 ₹50,400 | 100 ₹24,000 Lowest | 200 ₹48,000 |
| 7.00 | Supply only Liquid water proofing compound | 40 | Litre | 200 ₹8,000 | 80 ₹3,200 Lowest | 89 ₹3,560 |
| 8.00 | M&L for brushing neat cement slurry with 3.0 kg of cement per square metre complete all as specified and directed. | 300 | Sqm | 18 ₹5,400 Lowest | 50 ₹15,000 | 19 ₹5,700 |
| 9.00 | M&L for preparing RCC roof surfaces with wire brush drying and cleaning to remove all foreign materials and washing with water to remove loose particles and applying one coat of bituminous primer @ 200 gms per sqm and then laying 3 mm thick APP modified bituminous membrane weighing not less than 3.50 kg/sqm reinforced weighing not less than 160 gms/sqm laid by torch application method overlap while torching shall be 75 mm on length and 100 mm width side, all angles & bituminous should sealed with extra care to ensure full bondage all joints and changes covered with CM 1:3 mixed with water proofing chemical as per manufacturer's instructions and cured well before laying membrane etc and applying aluminium paint @ 100 gram / sqm on roof ,on vertical surfaces etc including removing the existing roof treatment of any description complete all as specified and directed. | 300 | Sqm | 550 ₹1,65,000 | 500 ₹1,50,000 | 402 ₹1,20,600 Lowest |
Tender Value
₹58.1 L
EMD Value
₹1.1 L
Closing Date
8 Aug 2025, 6:00 pmClosed
COMMANDER WORKS ENGINEER
COMMANDER WORKS ENGINEERS Pallavan Salai Chennai 600 002
SPECIAL REPAIRS TO BUILDING NO. P-46 CAPT MD ACCN UNDER GE AVADI
2025_MES_719905_1
87755/E8
Open Tender
Civil Works
Item Rate
180 days
GE Avadi
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE Avadi
₹1.1 L
12 Sept 2025
11 Jul 2025
11 Aug 2025
11 Jul 2025
8 Aug 2025
25 Jul 2025
Amount
B/R PORTION:
M&L for cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling the cracks with a hot mixture of bitumen and clean dry sand 1:1 (by weight) complete all as specified.
M&L for cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified.
Taking out shrubs / vegetation / tree growth from building at any height & any location and applying a Glyphosate pesticide or any other equivalent pesticide in a 10ml of solution mixed with one litre of water and apply on roots using spray gun including taking down cement plaster not exc 0.50 sqm for each tree and making good surface by plastering the same area with 20mm thick plastering in cement mortar 1:4mixed with and including WPC and finishing the surface to match with existing surface including necessary scaffolding and T&P as required at site complete all as specified and directed by Engineer-in- Charge.
Demolition of cement conctrete (un-reinfoeced) of any description and in any position not otherwise specifically provided
M&L for 40mm thick plain cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in padding concrete mixed with water proofing compound and finished even and fair complete all as specified and as directed. Note : Water proofing compound shall be measured and paid separately under relevant item.
M&L for screed bed 15 mm thick in cement mortar 1:4 mixed with water proofing compound as per Manufacturer's instructions for laying APP membrane complete all as specified and directed. Note : Water proofing compound shall be measured and paid separately under relevant item.
Supply only Liquid water proofing compound
M&L for brushing neat cement slurry with 3.0 kg of cement per square metre complete all as specified and directed.
M&L for preparing RCC roof surfaces with wire brush drying and cleaning to remove all foreign materials and washing with water to remove loose particles and applying one coat of bituminous primer @ 200 gms per sqm and then laying 3 mm thick APP modified bituminous membrane weighing not less than 3.50 kg/sqm reinforced weighing not less than 160 gms/sqm laid by torch application method overlap while torching shall be 75 mm on length and 100 mm width side, all angles & bituminous should sealed with extra care to ensure full bondage all joints and changes covered with CM 1:3 mixed with water proofing chemical as per manufacturer's instructions and cured well before laying membrane etc and applying aluminium paint @ 100 gram / sqm on roof ,on vertical surfaces etc including removing the existing roof treatment of any description complete all as specified and directed.
Dismantling of floor hearth or wall tiling including cement mortar bedding but not backing and removing rubbish off the primises complete all as specified and directed.
M&L for coloured glazed ceramic tiles of size 350x 250x 7mm/ 450X 350X 7mm/ 450 x 300 x 7mm thick as in vertical surface such as dado,skirting etc set and jointed in neat cement slurry and pointed in colour cement to match with the shade of tiles over and including backing coat / rendering 10mm thick in CM 1:4 complete all as specified
M&L for non-skid coloured ceramic tiles 7 to 8 mm thick (Square / Rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc. set and jointed in neat cement slurry and pointed in colour cement to match with the shade of tiles over and including over and including seceed bed / bedding layer of 15mm thick in cement mortar 1:6 complete all as specified .
M&L for joint free non-skid coloured ceramic tiles 7 to 8 mm thick (Square / Rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc. set and jointed in neat cement slurry and pointed in colour cement to match with the shade of tiles over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified
M&L for joint free non-skid coloured ceramic tiles 7 to 8 mm thick (Square / Rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in . set and jointed in neat cement slurry and pointed in coloured cement to match with shade of tile over and including backing coat / rendering 10 mm thick in CM 1:4 complete all as specified and directed.
M&L for light shade vitrified ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match with colour of tile over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified .
M&L for light shade vitrified ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm in vertical surfaces such as skirtings, dados and risers to steps etc set and jointed in neat cement slurry and pointed in coloured cement to match rwith the colour of tile over and including 10mm thick backing coat in CM 1:4 complete all as specified.
M&L for 40mm thick plain cement concrete 1:2:4 type B0 using 12.5mm graded stone aggregate as in sub base complete all as specified and as directed.
Demolition of precast concrete block walling and similar items i.e. ashlar facing dressing stone work, precast concrete articles etc of any description and in any position built in cement mortar including all quoins, arches and pillars etc. complete all as specified & as directed.
M&L for precast cement concrete solid block masonry made with PCC 1:3:6 type C1 using 20mm graded stone aggregate ,exceeding 10 cm in width and set and jointed in cement mortar 1:6 complete all as specified and directed.
Dismantling of structural steel work including doors, gates but excluding framed truss etc.complete all as specified and directed.
M&L for mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete confirming to Fe 410-W (Gde-E-250) quality-A complete all as specified and directed.
M&L for preparation of new or previously untreated steel surface of any description and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified .
Taking down of chowkhats / frames of any description not exceeding 1.50 sqm each without taking off shutter from the frame complete all as specified
Taking down of chowkhats / frames of any description exceeding 1.50 Sqm but not exceeding 4.0 sqm each without taking off shutter from the frame complete all as specified and directed.
S&F Powder coated aluminium (minimum 50 micron thickness of powder coating ) frame work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete all as per site requirement and as directed by Engineer-in-Charge.
S&F Powder coated aluminium (minimum 50 micron thickness of powder coating ) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass / stainless steel screws all complete all as per site requirement and as directed by Engineer-in-Charge.
S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per site requirement and direction of Engineer-in-charge.
S&F Anodised aluminium window powder coating of any colour (Thickness of powder coating not less than 50 micron). and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified.
S&F 5.5mm thick Sheet glass, ordinary quality and and glazing with oil putty in square not exceeding 0.5 sqm in each pane complete all as specified.
S&F in repairs 5.5mm thick Sheet glass, ordinary quality and and glazing with oil putty in square exceeding 0.5 sqm in each pane complete all as specified.
S&F 4mm thick figured glass, pin head type and glazing with oil putty in squares not exceeding 0.5 sqm in each pane complete all as specified.
S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F aluminium (extruded section) body door closer hydraulically regulated designation No 3, universal type,suitable for door shutters of 851 to 1000mm in width and weight between 61 to 80 kg complete all as specified .
Taking down cement plaster of any description from brick wall or concrete surfaces including racking out joints and hacking for key, scrubbing down with water etc complete all as specified
M&L for 15 mm thick plaster in cement mortar 1:6 on brick work / RCC concrete surfaces of wall and finish the surface even and smooth without using extra cement complete all as specified
M&L for 5 mm thick plaster in cement mortar 1:3 on brick work / RCC concrete surfaces of ceilings complete all as specified
M&L for rendering 15 mm thick in CM 1:4 on concrete / fair surfaces of block masonary mixed with water proofing compound as per manufactureres instructions and finished the surface even and smooth without using extra cement complete all as specified and directed. Note :- WPC shall be measured and paid for seperately under relevant item.
M&L for preparation of newly plastered ceiling surfaces and applied three coats of white wash complete all as specified
M&L for preparation of old plastered ceiling surfaces and applied one coat of white wash complete all as specified
M&L for preparation of newly plastered wall surfaces and applying 3mm thick wall care putty on wall to prepare the surface even and smooth, including priming plastered and other surfaces with alkali resistant priming paint and applying two coats of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification complete all as specified and directed
M&L for preparation of newly plastered wall surfaces and applying 3mm thick wall care putty on wall to prepare the surface even and smooth, including priming plastered and other surfaces with alkali resistant priming paint and applying distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete all as per Manufacturer's instruction / specification ,two or more coats on new work complete all as specified and directed by Engineer-in -Charge.
M&L for preparation of newly plastered wall surfaces and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali and fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed by Engineer-in -Charge.
M&L for complete removal of existing treatment on wall (any number of layers) by scarping with steel scrapers or any other mean and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified
M&L for complete removal of existing treatment from wall (any number of layers) by scarping with steel scrapers or any other mean including filling depressions of scrapped surface with putty and including priming plastered and other surfaces with alkali resistant priming paint and applying two coats of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification complete all as specified
M&L for complete removal of existing treatment from wall (any number of layers) by scarping with steel scrapers or any other mean including filling depressions of scrapped surface with putty and including priming plastered and other surfaces with alkali resistant priming paint and applying distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved Manufacturer, of required shade and colour complete all as per Manufacturer's instructions and specification ,two or more coats on new work complete all as specified and directed by Engineer-in -Charge.
Demoltion of cement concrete of any description in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified.
M&L for plain cement concrete 1:3:6 type C2 using 40mm graded stone aggregate , 75mm thick. as in plinth protection, finished even and smooth without using extra cement including providing expansion joints complete all as specified.
M&L for cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc from water tanks having capacity exceeding 1000 litres and not exceeding 2000 litres complete all as specified and directed.
Taking up or down steel tubing / CPVC Pipes with connection including cleaning for refixing or removed to store complete all as specified
16 mm bore dia
20 mm bore dia
25 mm bore dia
S&F CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed for the following sizes :-
16 mm outer dia
20 mm outer dia
25 mm outer dia
M&L for cutting chases not exceeding 10cm in girth for concealed water tubing and making good the disturbed surface in cement mortar 1:3 complete all as specified and directed.
S&F in repairs vitreous china wash down water closet pan (Pedestal pattern) white, including trap and connection to drain and flushing pipe (excluding flushing cistern) including seat cover with recessed bottom and mild steel chromium plated or aluminium hinging devices for pedstal pan and flush pipe of polyethylene of low or high density or PVC 32 mm dia, for low level cistern complete all as specified. Make : PARRYWARE / HINDWARE / CERA
S&F in repairs vitreous china premium / 1st quality wash down water closet wall hung EWC white/ ivory/off white (closed pattern)including all necessary accessories like rag bolts/ gel gasket etc. (excluding flushing cistern & flush pipe) including seat cover with flat bottom and mild steel chromium plated or aluminium hinging devices for pedstal pan and flush pipe of polyethylene of low or high density or PVC 32 mm dia, for low level cistern complete all as specified. Make : PARRYWARE / HINDWARE / CERA
S&F in repairs vitreous China squatting pan, 'Orissa patteren' of size 580 x 440 mm white, with integral foot rests including provision of lime concrete bedding (excluding flushing cisteren and flush pipe) and flush pipe of polyethylene of low or high density or PVC 32 mm dia, for low level cistern complete all as specified . Make : PARRYWARE / HINDWARE / CERA
S&F in repairs vitreous china wash basins, white, flat back, of size 630mm x450mm, including cutting for and pinning in ends of brackets or erecting stand but inclusive of waste couplings and waste pipe complete all as specified Make : PARRYWARE / HINDWARE / CERA
S&F in repairs PVC low level flushing cistern of 10 litres capacity with all accessories cobbected with WC including syphone pipe, PVC flushing pipe of required size complete all as specified .Make : PARRYWARE / HINDWARE / CERA
S&F in repairs PVC connection 15mm size PTMT nuts of length 450 mm. Make : JAQUAR /PRAYAG /CERA
S&F in repairs 15 mm bore fancy type angular valve cast copper alloy screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for unions complete all as specified. Make : JAQUAR /PRAYAG /CERA
S&F in repairs of two way bib cock chromium plated fancy type 15 mm bore with wall flange complete all as specified Make : JAQUAR /PRAYAG /CERA
S&F in repairs fancy type CP pillar tap with capstan heads, spindles and washer plates cofirm to IS 1795 having mark 'Cold' or 'Hot' and weight not less than 0.65 Kg complete all as specified Make : JAQUAR /PRAYAG /CERA
S&F in repairs CP wall mixer 3 in 1 system with provision for hand shower and over head shower and including 1.5m long tele shower screwed for iron pipe or CPVC Pipes or for brass ferrule of 15mm dia and fixed complete all as specified. Make : JAQUAR /PRAYAG /CERA
S&F in repairs 15 mm bore fancy type bib taps long body cast copper alloy chromium plated, screwed down, screwed for iron pipe or for brass ferrule. Make : JAQUAR /PRAYAG /CERA
S&F in repairs to health faucet of suitable size , 1200 mm long flexible outlet pipe and having 184.5mm length of handle with wall hook complete all as specified Make : JAQUAR /PRAYAG /CERA
S&F in repairs 15 mm bore overhead shower Brass chromium plated shower rose 125mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified Make : JAQUAR /PRAYAG /CERA
S&F in repair CP Soap dish of having size 160mm x 160 mm x 90mm fixed to plugs with brass screws complete all as specified Make : JAQUAR /PRAYAG /CERA
S&F in repairs tubular towel rail, 20mm dia, D type, 60cm long between flanges brass chromium plated complete all as specified Make : JAQUAR /PRAYAG /CERA
S&F in repairs CP Towel Ring round with round flange and not less than 280 gms complete all as specified Make : JAQUAR /PRAYAG /CERA
S&F in repairs CP Toilet paper holder with flat recessed type stainless steel fixed to walls with CP brass screws complete all as specified Make : JAQUAR /PRAYAG /CERA
S&F in repairs acrylic shelf having size of 56 cms x 13 cms with chromium plated bracket below WHB mirror complete all as specified Make : JAQUAR /PRAYAG /CERA
S&F in repairs SS cockroach trap / nahani trap of size 150mm x 150mm in sqaure shape SS 304 Grade glossy finish complete all as specified.
S&F in repairs SS floor drain trap in round shape of 125mm dia SS 304 Grade glossy finish with or without hole for waste pipe complete all as specified.
S&F in repairs PVC waste pipe / outlet connector pipe 32mm / 40mm dia of length 1150mm and corrugated profile for fixing in WHB / Sink complete all as specified.
S&F ball brass valves,high pressure,with polythene float and flunut complete, screwed for iron pipe or brass ferrule of 25mm bore and fixed complete all as specified.
S&F in repairs gun-metal,globe or gate valves,with iron wheel head, screwed both ends for iron pipe of 25mm dia and fixed complete all as specified .
M&L for dismantling water tanks of any description exceeding 500 litre but not exceeding 1000 litres capacity and removing to store ,suupply and fix Rotational moulded polyethylene water storage tanks 1000 litres capacity ,three layered (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed.
Taking down of chowkhats / frames not exceeding 1.50 sqm each without taking off shutter each complete all as specified and directed.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm single piece extruded PVC profiles reinforced with 19 x 19mm MS square tube provided with EPDM rubber gasket weather seal through out the frame and the profile mitre cut at two corners and joined by inserting 2 nos 150mm long brackets of 15 x 15mm MS square tube inside 19 x 19mm MS square tube suitably screwed complete all as specified.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes of size 15 x 15mm for top and bottom rails and 19 x 19mm for stiles, MS frame covered with 5mm thick single piece extruded PVC profile 'C' channel having a 5mm thick PVC sheet strip of 20mm width struck inside with solvent cement, forming stiles, and 5mm thick single piece extruded PVC profile for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail; panelling of 5mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with PVC sheet beading, and joined together with solvent cement adhesive etc all as per Manufacturer's instructions and drawings as shown in SSR Part-I 2009 complete all as specified.
S&F aluminium anodised barrel tower bolts of extruded section of 200 mm long
S&F Extruded aluminium alloy handles, fabricated type, anodised of size 150mm
S&F butt hinges extruded aluminium alloy with galvanized mild steel hinges pin anodised type `C'-22 of size 100mm
S&F in repair sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F in repair sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes including bedding in cement morter to dwarft wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F waste fittings of size 40mm brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed.
S&F stainless steel decorative curtain rod of 25 mm bore (weight not less 400 gms per Rm) with and including fancy finale caps (02 nos in each curtain rod) complete all as specified and as directed
S&F Brass chromium plated designer bracket for curtain rod of 25 mm dia made out of SS flat not less than 20 mm wide 1.50 mm thick and overall length not less than 160 mm fixed with screws (minimum 2 Nos) with rawl plug of size not less than 50 mm long etc complete all as specified and as directed .
Taking down door Shutters of any description area exc 2 sqm but not exceeding 4.0 sqm each complete all as specified and directed.
Taking down door Shutters of any description area exc 1.0 sqm but not exceeding 2.0 sqm each complete all as specified and directed.
S&F Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed.
S&F Mild steel small articles such as hold fast, etc of Gde Fe 410-0 or Fe-290 Gde E-165 complete all as specified and directed.
M & L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in hold fast etc completed all as specified and directed.
M&L for preparation of wood and wood based materials, new or old, of any description and girth, not otherwise described, and treating ends of posts,back of chowkhats,etc. area tarred exceeding 0.1 sqm but not exceeding 0.5 sqm each and treated with tar or coal tar black paint complete all as specified and directed.
M&L for preparation of wood and wood based materials, new or old, of any description and girth, not otherwise described, treating small articles such as holdfasts,end of posts,backs of chowkhats, etc area not exceeding 0.1 sqm each and treated with tar or coal tar black paint complete all as specified and directed.
S&F 35 mm thick second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers , etc.; sizes of members of shutters all as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed.
S&F 35mm thick factory made second class hardwood plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces the size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified
S&F 30 mm thick flush shutter, solid core construction, with block board core and plywood face panel, commercial type on both sides complete all as specified
S&F aluminium anodised 200 mm barrel tower bolts of extruded section
S&F 150mm Extruded aluminium alloy handles, fabricated type, anodised
S&F 100 mm butt hinges extruded aluminium alloy with galvanized mild steel hinges pin anodised type `C'-22
S&F 300mm long aluminium alloy, anodised sliding door bolt with haps, staple(bolt type) and fixing clip of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified
S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed.
M&L for providing water proofing treatment to sunken portion of WCs, bathroom etc by applying cement slurry mixed with two component Elastomeric Acrylic based polymer modified cementitious composite compound coating. including taking down existing treatment , demolition of PCC in sunken protion of Toilet, Bathroom etc and removing the debries beyond the premises off site and carry out the following : - (a) M&L for cleaning of the sunken / lowered portion of the RCC slab surface (including vertical total depth plus 300mm above FFL) of floors by wire brush, chiesel out any mortar sticking to the surface and brooming / washing completely. (b) Rendering of uneven surfaces with 5 mm thick CM 1:4 mixed with and including integral liquid WPC as per Manufacturer instruction. Testing dampness and seepage by filling the entire area with water ,if seepage noticed , nozzles shall be fixed and epoxy grouting to be carried out. (c) All junctions points of side walls where PVC pipes are passing through shall be sealed with epoxy putty and After drying of putty, washing the slab and sides of sunken portion with water and make it clean and clear.
(d) Applying first layer of slurry of cement @ 0.488 kg/sqm mixed with Acrylic based polymer modified cementitious composite compound @ 0.253 kg/sqm. The layer will be allowed to air cure for 4 hours. (e) Applying second layer of slurry of cement @ 0.242 kg/sqm mixed with with Acrylic based polymer modified cementitious composite compound @ 0.126 kg/sqm. The layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (f) Provide 40mm dia medium grade GI spout at the lowest point with 400mm long. (g) 50 mm average thick PCC 1:2:4 type B0 using 12.5 mm graded aggregate as in padding concrete to achieve proper slope mixed with WPC and All pipes laid in sunken portion shall be covered with 50 mm thick PCC 1:3:6. (h) Cement concrete PCC 1:5:10 type E2 using 20mm graded brick aggregates as in sunken portion. (j) 20mm thick screed bed in cement mortar 1:3 mixed with liquid water proofing compound.
Note : (i) For Payment purpose, plain area of Sunken portion shall be measured. (ii) Testing the water proofed area (ponding test) by filling water for atleast 72 hours and tested for leakage seepage and to the entire satisfaction of GE . (iii) Test shall be done in presence of Representative of user and photographical record for each sunken slab shall be maintained and produced during payment (iv) The treatment shall be carried out by the Authorised applicators of chemicals Manufactuer.
S&F factory made 18mm thick single extruded WPC (Wood Plastic composite) solid board of any colour, texture and pattern for cup board as in Kitchen cabinet and loft shutter and similar nature of work of required sizes comporising of virsin polymer of K Value 58-60 (Suspension grade), Calcium carbonate and natural fibres(wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density 650kg/cum and screw withdrawl strength of 1800N (Face) & 900 N (Edge) , minimum compressive strength 50 N/mm2, modulus of elasticity 850N/mm2 and resistance to spread of flame of Class A category with property of being termite / borer proof, water / moisture proof, and fire retardent complete all as per Manufacturer instruction.
S&F stainless steel Auto / Self closing concealed hinges 9.5 cranks for half overlay doors with opening angle 95* (14-32mm) with integrated overlay adjustment +_ 2.50mm & depth adjustment 4mm complete all as specified. Make : Godrej / Hettich.
S&F stainless steel handle of size 6" for basket all as specified and directed.
S&F round stainless steel cabinet knobs handlers of 27mm dia all as specified.
S&F stainless steel modular plate rack of size 50.80 x 53.3 x 20.30 cm with telescopic drawer channel having weighing capacity of 6 kg complete all as specified and directed.
S&F stainless steel modular cup & saucer holder basket of size 50.80 x 53.3 x 10.20 cm with telescopic drawer channel having weighing capacity of 4kg complete all as specified and directed.
S&F floor door stopper of aluminium alloy body and tongue, anodised , with hard drawn steel spring overall length of cover plate 140 mm, complete all as specified and directed.
M&L for preparation of new wooden surfaces of any description, not otherwise described,over 10 cm in width or girth and applying two coats of synthetic enamel paint (ordinary paint tint) over a coat of pink primer including scaffoldings of any hieght complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons,dados etc laid, bedded and pointed in any mortar and removal of rubbish off the site complete all as specified and directed.
M&L for granite (of any colour) 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixure of pigment to match the shade of granite stone including grinding and polishing as in kitchen platform, counter for wash basin, flooring and all other similar works over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 20-25mm thick in flooring ,laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing ,over and including 15mm thick screed bed mortar in CM 1:4 complete all as specified.
M&L for Machine cut kota stone slab flooring 20-25mm thick as in riser of steps, skirting, dado and pillar laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including backing coat / rendering 10 mm thick in CM (1:4) complete all as specified and directed.
Demolition and breaking up drain pipes of 100 mm /110 mm dia of Salt glazed ware / AC / PVC / reinforced concrete etc set in cement mortar complete all as specified and directed.
Demolition and breaking up drain pipes of 75 mm dia of Salt glazed ware / AC / PVC / reinforced concrete etc set in cement mortar complete all as specified and directed.
S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to wall with suitable clamp complete all as specified
S&F 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to wall with suitable clamp complete all as specified
S&F PVC (SWR) junction single, (single T) equal or unequal provided with access door suitable for 110mm bore PVC pipes complete all as specified
S&F PVC (SWR) bends any radius suitable for 110mm bore PVC pipes with access door complete all as specified
S&F PVC (SWR) bends any radius suitable for 75mm bore PVC pipes with access door complete all as specified
S&F PVC (SWR) vent cowl for 110mm bore PVC pipes complete all as specified
S&F PVC (SWR) WC connector bent type for 110mm bore PVC pipes complete all as specified
S&F PVC (SWR) for 75mm Diameter of outlet floor trap, plain with grating including jointing with solvent cement etc complete all as specified
S&F PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement complete all as specified
INTERNAL ELECTRIFICATION:
Taking down carefully unserviceable point wiring copper / aluminium (light, fan, socket or power) complete, including removal of batten / conduit / gutties / wooden board etc., including fittings and fixtures such as switches, ceiling roses, regulators, sockets, light fittings, fans etc.,removal from site under Sch of credit and removal of unserviceable items out of site and making good the disturbed surfaces of walls, ceilings etc.,complete all as specified and as directed.
M&L for point wiring on stone / brick masonry wall complete with two nos of 1.5 sqmm single core PVC insulated FRLSH ,1100 volts grade unsheathed cable confirming to IS-694, 1977 with multistranded copper conductor, drawn through and including non-metalic rigid PVC conduit, conduit fittings and conduit accessories not less than 20 mm dia concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc., and including provision of one 1.5 sqmm PVC insulated single core multistranded copper conductor FRLSH green in colour as earth continuity conductor and connected to common earth dolly, including Modular boxes, frames and cover plates all as specified complete for the following : Note : Quoted rate shall be inclusive of Modular box, frame, cover plates and cutting chases for concealing pipes etc for point wiring.
One light point controlled by one way switch.
One ceiling fan point controlled by one switch and regulator
One Exhaust fan point controlled by one switch.
One bell / buzzer point controlled by one bell push
One switch socket outlet 3 pin 5 Amps on same board along with other switches
One switch socket outlet 3 pin 5 Amps on independent board.
One light point controlled by two, two way switch.
All as per item No 128 here-in-before but for point wiring with two nos of 4.0 sqmm single core copper conductor multistranded FRLSH cable and one 4.0 sqmm PVC insulated single core multistranded cable as earth continuity conductor green in colour including steel box of required module for modular switches/sockets all as specified for one 3 pin switch socket outlet, 15 Amps, complete all as specified and as directed.
S&F Modular switch 1 way 6A, 1 module
S&F Modular switch 2 way 6A, 1 module
S&F Modular switch 1 way16A, 1 module
S&F Modular Bell push 6A, 1 module
S&F Modular Socket, 6A - 2/3 pin combined 2 module
S&F Modular Socket, 6A/16A - 2/3 pin combined 2 module
S&F Modular fan step regulator , 120w, 2 module
S&F ceiling rose 65 X 50 mm , three terminals ,bakelite , surface
S&F Bell ding-dong type , AC, 215 volts, 50 HZ
S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings
S&F LED Bulbs 9/10 Watts suitable for B-22 base holders
Taking down carefully the existing power / Sub main wirings of any description and in any position and removing materials from site, taken as credit , making good the disturbed surfaces complete all as specified and as directed.
S&F power / submain wiring with PVC insulated unsheathed, FRLSH ,1100 volts, grade multistranded copper conductor, two runs of single core 4 sqmm conforming to IS-694, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories alongwith one run 4 sqmm PVC insulated single core multistranded copper conductor cable (green) as earth continuity conductor concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc. and connecting to common earth dolly complete all as specified and as directed. Note : 2 runs of 6 sqmm single core multistandred copper conductor and one run of earth conduit conductor and one length of PVC conduit and its accessories shall be measured as one unit length.
S&F power / submain wiring with PVC insulated unsheathed, FRLSH ,1100 volts, grade multistranded copper conductor, two runs of single core 6 sqmm conforming to IS-694, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories alongwith one run 6 sqmm PVC insulated single core multistranded copper conductor cable (green) as earth continuity conductor concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc. and connecting to common earth dolly complete all as specified and as directed. Note : 2 runs of 6 sqmm single core multistandred copper conductor and one run of earth conduit conductor and one length of PVC conduit and its accessories shall be measured as one unit length.
S&F sinngle pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified.
Taking down existing unserviceable MCB's/MCCB's/DBs of any size and capacity complete all as specified
S&F Load line MCB DB TP&N 4 way, vertical, double door, powder coated, 415 volts, AC, 50Hz, IP 54 protected, fixed on wall semi flush with provision for FP MCCB 125 Amps as incomer and SP MCBs 32 amps as outgoing with tinned copper bus bar, neutral link, earth link and connecting up complete all as specified and as directed. Note : Incoming and Outgoing MCB shall be measured and paid separately under relevent items.
S&F TPN vertical DB 4 way double door made out of CRCA sheet housing duly powder coated with provision for MCB's and including supply of 4P 63A and SP MCB out goings completed all as specified and directed.
S&F MCB DB SPN 04 way, double door, powder coated, 240 volts, AC, 50Hz, IP 43 protected, with provision for MCB double pole as incomer and SP MCBs as outgoing with tinned copper bus bar, neutral link, earth link and connecting up complete all as specified and as directed. Note : Incoming and Outgoing MCB shall be measured and paid separately under relevent items.
S&F 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified.
S&F 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and Neutral current carrying capacity 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified.
S&F 415V, 10 KA 'B' curve miniature circuit breaker (MCB) of four pole current carrying capacity 40 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified.
S&F MCCB 125 Amps 415V,16KA, 4 Pole complete all as specified .
S&F LED lights fitting 1x 20 W / 22W, 220V,AC with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified.
S&F LED light fitting mirror type with high out put diffuser 2 feet, 9/10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified.
S&F LED light fitting 1x9W / 1X10W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified.
S&F LED building security light fitting 30watts made up of pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07, complete pre-wired and connecting up with suitable twin core flexble copper wire including provision of necessary GI tubing medium grade 25mm bore of pipe 1.5 bent to shape with necessary clamps made out of mild steel, nuts and bolts etc., including two coats of synthetic enamel paint over a coat of red oxide primer on exposed steel surface for fixing the fitting to Bldg etc complete all as specified and as directed.
S&F ceiling fan BLDC type complete with accessories 230 V,1400 mm sweep. BEE 5 star rated with and including provision of necesary hanging hook on ceiling and removing the existing old fan and deposit to MES store yard complete all as specified and directed.
S&F Exhaust fan, heavy duty, 300 mm sweep, 1370 RPM, with louvers, metal body conforming to IS, AC single phase, 240 Volts, 50 Hz and connecting including provision of two way PVC connectors, 1.50 sqmm flexible three core multistranded copper conductor cable from ceiling rose or connector to fan including earthing and making suitable hole in wall to fix the fan and finish the disturbed surfaces of wall to match with existing finishing including removing old fan of any description and deposit to MES store yard complete all as specified and directed.
S&F Ventilation fan 200mm sweep, power 22 watts, Operating voltage 230 Volts with louvers and shutters plastic body type including necessary civil work as required at site to fix the fan and alteration in exist ventilation window of iron/aluminium frame for fixing of fan as per site requirement complete and making good the wall/ventilation window to match with existing complete with all accessories and connecting up with suitable size 1 sqmm three core copper conductor flexible wire,screws,gutties complete all as specified and directed.
S&F water heater storage type, electric, BEE 5 star rated of 25 litres capacity including inlet and out let pipes as required , adjustable thermostat, Efficient long-life copper heating element, shock-resistant and rust-proof engineering, thermoplastic body, IPX4 waterproof technology, tank designed to withstand 8 bar pressure, tank marine grade glass line coated,PUF insulation, Magnesium anode complete with all fixing arrangements as required at site all as specified and directed.
M&L for earth continuity conductor or main earthing lead with 4mm dia galvanised steel wire fixed on wall / batten or recess or chases or burried in ground or drawing in conduit or any other situation for loop earthing etc complete all as specified and directed
M&L for earthing complete with galvanised iron earth plate electrode 600mm X 600mm X 6mm thick, with and including earthing of 4mm dia GI wire protected by 15mm dia GI pipe light grade upto a length of 7.5m. The plate shall be buried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of the earth plate at a depth not less than 1.5 metres below ground level, connected to earth lead as described here-in-before by means of bolts, nuts, washers and checknuts made out of galvanised iron or mild steel, earthing lead protected by as described here-in-before and connected to main switch board or main control board or electric pole all as shown on electrical plate No.3 of MES Sch Part-I including necessary earth work and excavation in any type of soil, plain cement concrete 1:3:6, type C1 chamber, reinforced cement concrete cover slab with locking arrangement and handle of 10mm dia MS round bars 450mm long, 1:2:4 type B1, 50mm thick with 8mm dia TMT bars at 140mm centre to centre both ways, GI pipe of bore 20mm medium grade for watering with funnel, wiremesh, salt, charcoal, lugs including testing complete all as specified and as directed.
EXTERNAL ELECTRIFICATION:
Supply, laying and testing XLPE Insulated,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables 1100 Volts grade with stranded aluminium conductor of size 50 sqmmx 3.5 core complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in any type of soil for laying cables / pipes / erection of poles etc all as specified and as directed.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
Returning filling in soil including spreading leveling watering well ramming in layers not exceeding 25 cm each all as specified and as directed.
Labour for filling the fine seived excavated dry soil laid to the required thickness in trench as a cushioning to cable complete all as specified . Note :- Thickness shall be measured after punning
Supply and laying of common burnt clay building bricks, sub class B for cable protection all as specified
M&L for GI tubing light grade 50 mm dia for cable protection laid in trenches / in road crossing or fixed to wall / Pole complete all as specified and as directed.
M&L for Cutting of road / path of suitable width and deprth as directed for laying of GI tubing and making the good the disturbed road / path with and including provision of plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregate all as specified and directed.
SAMYDOSS CONSTRUCTIONS (BID ID -3379694)
SWIFTTECH ENGINEERS INDIA PVT LIMITED (BID ID -3387166)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .