Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹85.8 LAccepted-AOC 9 EZRA STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | ₹85.8 L Quoted ₹86.0 L | L1 | Accepted-AOC LOWEST AND RESONABLE |
| 2 | L2₹90.2 L+₹4.3 L (4.94%)Rejected-Finance | ₹90.2 L+₹4.3 L (4.94%) | L2 | Rejected-Finance NOT BEING LOWEST |
| 3 | L3₹1.0 Cr+₹15.7 L (18.2%)Rejected-Finance | ₹1.0 Cr+₹15.7 L (18.2%) | L3 | Rejected-Finance NOT BEING LOWEST |
| 4 | L4₹1.0 Cr+₹17.5 L (20.3%)Rejected-Finance 244 22 ONKAR NAGAR B TRI NAGAR TRI NAGAR NEW DELHI 110035 NORTH WEST DELHI DELHI 110035 INDIA | NORTH WEST DELHI | DELHI | 110035 | ₹1.0 Cr+₹17.5 L (20.3%) | L4 | Rejected-Finance NOT BEING LOWEST |
| 5 | L5₹1.1 Cr+₹19.4 L (22.5%)Rejected-Finance HARSHA KUTHI SIDDHESWARITALA ROAD MONIRAMPORE BARRACKPORE DIST 24 PARGANAS NORTH KOLKATA 700120 W B | KOLKATA | 24 PARGANAS NORTH | WEST BENGAL | 700120 | ₹1.1 Cr+₹19.4 L (22.5%) | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹1.4 Cr
EMD Value
₹2.1 L
Closing Date
11 Jun 2020, 6:00 pmClosed
CWE Kolkata
Headquarters commander Works Engineers Military Engineer Services No 1, National Library Avenue Alipore, Kolkata 700 027
PROVISION OF RING MAIN UNIT (RMU) AT FORT WILLIAM UNDER GE FORT WILLIAM KOLKATA
2020_MES_340862_1
8058/E8(E-03)/20-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE_FW Kolkata
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
Yes
GE FW KOLKATA
₹2.1 L
Yes
20 Jul 2020
25 Apr 2020
13 Jun 2020
25 Apr 2020
11 Jun 2020
18 May 2020
25 Apr 2020 - 15 May 2020
Amount
NOTES :(i)The bidders/contractors are advised to read tender document & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates. (ii) It is highlighted that the cretin condition of General Condition Of Contracts (IAFW-2249) has been modified as direction of MOD i.e inclusion of performance security, deletion of risk & cost provisions and increase in defects liability period all as specified in tender document. The tenderers should keep in mind while quoting their offer
Material and labour for straight through heat shrinkable type joints using jointing kit suitable for 6.6 KV PVC (UE)/ XLPE insulated aluminium conductor cable of cross sectional area 95 Sqmm 3 core including testing on completion complete all as specified and as directed by the Engineer-in-Charge .
Dismantling the existing four Pole/Six pole structure including tubular pole, cross arms , insulators etc all as specified and directed by the Engr-in-Charge.
Supply ,installation,testing and commissioning Ring Main Unit (RMU) outdoor type 6.6 KV 3 way outdoor type , 630 Amps 21 KA for 3 sec motorised Ring Main Unit type CCV +M comprising with 2 Nos SF6 insulated Load break switch for incomming and 1 No SF6 Vaccum Circuit breaker panel encapsulated inside a steel tank including necessary wiring for complete all as specified and directed by Engineer-in -charge. Note : The equipments shall must have the following technical data STANDARDS AND MECHANICAL DATA (a) Metal Enclosed switchgear : IEC 62271-200 (b) General Purpose switches : IEC 60265-1 (c) Disconnectors and Earthing switches : IEC 62271-102 (d) Switch Fuse Combination : IEC 62271-105 (e) Circuit Breakers : IEC 62271-100 (f) Common clauses : IEC 60694 (g) Pressure of SF6 gas : 1.4 bar at 20 °C (h) Cable bushings : DIN 47636 (j) Temperature class : -25 °C - +40 °C Outdoor (k) Degree of protection : SF6 tank: IP 67, Front cover: IP 2X, Cable cover: IP 3X , Enclosure IP 54 (l) Busbars : 240 mm2 Cu, (m) Earth bar (external): 120 mm2 Cu - Bolt dimension : M10 (n) Thickness of Stainless Steel Tank : 2.5 mm (o) Colours : Front cover: RAL 7035, Side and cable cover: RAL 7035, Enclosure : IS 632 ELECTRICAL DATA – 12 kV - 28kV-1min (a) Nominal voltage : 6.6 kVRated frequency: 50 Hz (b) Rated current busbars: 630 A (c) Rated current cable switch disconnector : 630 A (d) Short time withstand current: cable switch disconnector with interface C (400-bolt) (e) bushing: 21 kArms 3 sec. (f) vacuum circuit breaker with interface C (400-bolt) (g) bushing: 21 kArms 3 sec. (h) Internal Arc : 21kA for 1 sec, with gas exhaust form Top (j) Rated current for transformer T-off : 200 / 630 A (k) Impulse withstand voltage : To earth and between phases: 75 kV (l) Insulation level: Power frequency 1 min : 28 kV
All as per item No 3 above but outdoor type 6.6 KV 4 way outdoor, 630 Amps 21 KA for 3 sec motorised Ring Main Unit type CCVV+M comprising with two Nos SF6 insulated Load break switch and two Nos SF6 Vaccum Circuit breaker panel all as pecified and directed by Engineer-in -charge. Note : All as per Item No 3 above
Material & Labour for PCC (1:3:6) type C-2 using 40 mm graded aggregate as in foundation filling and mass concrete including providing necessary form work complete all as specified and as directed by the Engineer-in-charge
Material and labour for PCC (1:2:4) type B1 (using 20 mm graded crushed stone aggregate), as in coping of poles /pipes/strip alignment and RMU etc incl necessary formwork and finishing the exposed surfaces even and smooth without using extra cement, complete all as specified and as directed by the Engineer-in-charge.
Supply and fixing 100 mm bore galvanized iron pipe (light grade) with all fittings, fixed to wall /ceiling or laid in floor complete all as specified and as directed by the Engineer-in-charge.
Supply, laying and testing 6.6 KV (UE) XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor of size 3 core 95 Sqmm complete all as specified and as directed by the Engineer-in-charge. . Make- Havells or equivalent in Polycab/Gloster
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation, etc and getting out in soft/loose soil complete all as specified and directed.
Material and labour for sand cushioning /sand covering for underground cable protection and consolidated and compacted with clean dry sand complete all as specified and as directed. (Note: Thickness after punning down shall be measured for payment)
Supplying and laying un-reinforced precast concrete cable cover, class HVP, Type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and as directed.
Removal of excavated material to a disance n.exc 50 mtr and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed.
Returning , filling in including spreading levelling watering and well ramming in layers n.exc 25 thick for soft/loose soil complete all as specified and as directed.
Supply and fixing heat-shrinkable indoor type cable end jointing kit suitable for 6.6 KV PVC / XLPE insulated aluminium conductor cable of size 95 Sqmm 3 Core including testing on completion complete all as specified and as directed by the Engineer-in-Charge. Make- 3M or equivalant in RAYCHEM/M Seal /Denson
Material and labour for Earthing complete with Galvanised iron earth plate electrode 600mm x 600mm x 6mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below ground level connected with galvanised earthing strip of size 32mm x 6mm by means of nuts, bots, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (reinforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not esceeding 50 Mtr etc all as shown on electrical plate No.3 of MES Schedule Part-I complete including taking down and testing on completion complete all as specified and as directed by the Engineer-in-Charge.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including supply and laying of HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
Supply and fixing HT cable Route Indicactor manufactured from Cast Iron / Mild steel of minimum size i 600 x 300 x 50 mm complete all as specified and directed .
Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ.
JAZZCON ENGINEERS PVT LTD
M/s Debendra Prasad Gupta
NIRMAL SALES CORPORATION
MERCANTILE AGENCY
R K TYAGIS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .