Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.0 LAccepted-AOC E 73 FF GALI NO 17B SADH NAGAR PALAM COLONY NEW DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | ₹11.0 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹11.5 L+₹49,989.17 (4.54%)Rejected-Finance 13 218 MASJID EXTEN SADAR BAZAR | ₹11.5 L+₹49,989.17 (4.54%) | L2 | Rejected-Finance Rejected |
| 3 | L3₹12.9 L+₹1.9 L (17.1%)Rejected-Finance | ₹12.9 L+₹1.9 L (17.1%) | L3 | Rejected-Finance Rejected |
| 4 | L4₹13.5 L+₹2.5 L (22.4%)Rejected-Finance | ₹13.5 L+₹2.5 L (22.4%) | L4 | Rejected-Finance Rejected |
| 5 | L5₹13.7 L+₹2.7 L (24.7%)Rejected-Finance | ₹13.7 L+₹2.7 L (24.7%) | L5 | Rejected-Finance Rejected |
Tender Value
₹14.5 L
EMD Value
₹29,000
Closing Date
3 Aug 2020, 6:00 pmClosed
CWE New Delhi
HQ CWE New Delhi, Rao Tula Ram Marg, Delhi Cantt-10
Provn of 01 transformer 400 KVA for Dundahera Mil Stn Gurgaon under GE (South), Delhi Cantt-10
2020_MES_334611_1
CWE-ND/72/2019-20
Open Tender
Miscellaneous Works
Item Rate
180 days
Delhi Cantt
Please refer tender document
9 documents required · 9 mandatory
₹500
GE (South)
₹29,000
Yes
23 Sept 2020
1 Jun 2020
4 Aug 2020
1 Jun 2020
3 Aug 2020
27 Jul 2020
Amount
Supply, installing, testing and commissioning outdoor type, step down transformer, 11 KV/433 Volts (at no load) AC 3 phase 50 Hz, 400 KVA capacity, core type, double copper wound, oil immersed, naturally cooled, Oil Natural-Air Natural (ON AN), with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group Dyn-11 with Neutral brought out on secondary side (LV side) and having tapings at +5% to -10% on HV side to be changed by means of hand operated off load tap changer gear. The maximum temperature rise should not exceed 45 degree celsius in oil and 55 degree celsius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temp of 40 degree celsius. The transformer shall be conforming to IS-1180 Part-1 2014 and BEE certified (not below level-ll) with standard fitting including construction of suitable size of stone masonary platform with cement morter 1:4 with necessary finishes & painting. Platform size including fencing with chain link fixed with suitable size of Angle Iron and Openable door , fabrication works & finishes as per IS standard or as per manufacturer instructions complete all as specied directed . MAKE:- Voltamp transformers Ltd/ ITE transformers Gurgaon/ JAYBEE Industries/ Bharat Bijlee/Schneider/ Crompton Greaves/ Andrew Yule/ Alstom.
Supply and Installation of Ring main unit indoor type, manual operated with Rated voltage 12 KV,Rated frequecy 50 HZ,Rated short time curret 21 KA,Rated short time 3 Seconds and bus bars of 630 Amps SF6 insulated 3 way RMU (01 No incoming and 02 Nos outgoing ) (Right side Extensible/Indoor FBX-RE/12-21/CCC /-Manual) with standard fitting including Supply and replacement one set CT of ratio 100/1 or 5 A to existing RMU.all as specied directed . Makes:- Schneider/ Siemeans/ ABB
Supply and Laying XLPE insulated screened , Pvc Bedded, galvanised steel strip or wire armoured , electric power cables(heavy duty ) with aluminium conductor, 11000 volts grade cross sectional area 95 Sqmm 3 Core, laid in trenches, ducts along the walls, through pipes,or fixed on pole etc complete all as specified and directed.
Supply and laying XLPE insulated armoured heavy duty electric cable with aluminium conductor (Stranded) 1100V grade cross-sectional area 240 Sqmm 3.5 core laid in trenches or passing through pipe or fixed on pole etc complete all as specified and directed .
M & L cable Jointing Kit for 11 KV ( Earthed) grade cable for Indoor termination heat shrinkable end joint complete with jointing material and accessories suitable for 3 core XLPE Armoured aluminium cable of size 95 Sqmm complete all as specified and directed .
M & L cable Jointing Kit for 11 KV ( Earthed) grade cable for outdoor termination heat shrinkable end joint complete with jointing material and accessories suitable for 3 core XLPE Armoured aluminium cable of size 95 Sqmm complete all as specified and directed .
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the Galvanised iron strip 25x4 mm by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth wire protected by provision of GI light grade pipe 40 mm bore including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 5 of SSR 2009 Part-I and connecting to Transformer / RMU all as specified or indicated including testing on complete all as specified and as directed .
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing/connecting as required 25x4 mm galvanised iron strip complete all as specified and directed .
M & L test point terminal block made of gun metal or phosphorus bronze size gun metal or phosphorus bronze size 75 X 75 X 25 mm, drilled and screwed including 3 nos. 8mm dia 25 mm long hex. Head screw.
M &L tubes galvanised in repair with all fittings and fixed complete to walls and ceilings or laid in floors/with pole/trenches "Light grade" 80 mm dia for the protection of the U/G cable complete all as specified and as directed .
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m depth for laying of cable/ stay assy/LT poles and getting out in hard/dense soil complete all as specified and directed.
Returning filling incl spreading watering and well ramming in layers not exceeding 25cm in hard and dense soil.
Removing excavated material not exceeding 50 mtrs and depositing where directed at a level n. exc 1.5mtr above the starting point.
Sand cushioning to underground cable complete all as specified in clause 19.75 of SSR Part - I.
Supplying and laying reinforced precast concrete cable cover class LV, Type 1, flat, size 250mmx 150mm x 40mm for mechanical protection of cable with width equal to lenght of brick. complete all as specified & directed .
M&L for well burnt sub class 'B' bricks of nominal size 230X115X75 mm abutting each other for mechanical protection of cable with width equal to lenght of brick. complete all as specified & directed .
verma enterprises
aggarwal engineers contractors
Baliyan Electrical Works
AVON ELECTRICALS
M/s KUNDU CONSTRUCTION
M/s VINOD KUMAR SHARMA
Ridhi engineers and builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .