Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.5 LAccepted-AOC | L1 | Accepted-AOC tenderaccepted | |
| 2 | L2₹18.5 L+₹3.5 L (23.6%)Rejected-Finance | L2 | Rejected-Finance not being L1 | |
| 3 | L3₹20.4 L+₹5.4 L (36.0%)Rejected-Finance | L3 | Rejected-Finance not being L1 | |
| 4 | L4₹20.7 L+₹5.8 L (38.7%)Rejected-Finance | L4 | Rejected-Finance not being L1 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
13 Oct 2020, 6:00 pmClosed
GE Faizabad
GE MES Faizabad
REPAIR MAINT OF DG SETS PUMPS MOTORS TREATMENT PLANTS AND SUPPLY OF CHLORINE AND ALLIED WORKS UNDER AGE EM AT GE FAIZABAD
2020_MES_376364_1
8112/E8
Open Tender
Civil Works
Works
270 days
Faizabad
As per render documents
7 documents required · 7 mandatory
₹500
Yes
GE Faizabad
₹50,000
Yes
23 Nov 2020
10 Sept 2020
14 Oct 2020
10 Sept 2020
13 Oct 2020
23 Sept 2020
Amount
S & F MCCB 4 pole 100 Amp, 415 volt, 25 kA in existing panel including taking out of old one all as specified and as directed. Make:- L&T / C&S/ Schneider / ABB / Seimens.
S & F On load Changeover 4 pole 100 Amp, 415 volt, open execution type in existing panel including taking out of old one all as specified and as directed. Make:- L&T / C&S/ Schneider / ABB / Seimens.
S & F digital type Voltmeter with LED display suitable for 3 phase with accuracy class 1 in existing panel including taking out of old one all as specified and as directed. Make:- L&T / C&S/ Schneider / ABB / Seimens.
M & L for 3 pole power contactor 415 volts with 70 Amp AC3 duty rating 2 NO + 2 NC in existing panel including taking out of old one all as specified and as directed. Make:- L&T / C&S/ Schneider / ABB / Seimens.
M & L for electronic timer for automatic star delta starter 415 volt 50 Hz 3 - 30 sec in existing panel including taking out of old one all as specified and as directed. Make:- L&T / C&S/ Schneider / ABB / Seimens.
S & F digital type Ammeter with LED display suitable for 3 phase with accuracy class 1 in existing panel including taking out of old one all as specified and as directed. Make:- L&T / C&S/ Schneider / ABB / Seimens.
S & F tape wound ring type Current Transformer suitable for Bar primary of rating 100/5 Amp, burden 5 VA of make: Kappa/ Matrix in existing panel including taking out of old one all as specified and as directed
S & F Single phase Preventer Relay with adjustable time delay 30 sec to 5 min suitable for 415 volt AC, SPPR type, including internal wiring from switchgear to relay in existing panel all as specified and as directed. Make:- L&T / C&S/ Schneider / ABB / Seimens.
S & F Three phase submersible pump controller with single phase preventer of rating 3 phase,415V,50 HZ, 40 HP ,Type MU-G40 FAS including taking out of old one all as specified and as directed. Make:- L&T / C&S/ Schneider / ABB / Seimens.
Supply only bleaching powder in 25 Kg bag (ISI marked) grade II all as specified and directed by Engr-In-Charge (Make : Punjab Alkalies/Modi Alkalies/Sriram as approved).
Supply only sodium hypochloride liquid (chlorine content 10%) duly packed in sealed drum of make: M/s Declibac/ M/s Rayalshima Enterprise/ Bajaj Chemicals all as specified and as directed and approved.
Collection of water samples of bore wells located in deferent pockets of cantonment area in decontaminated sterilised bottles and testing of water samples for following essential parameters for drinking water as per IS:10500- 2012 from Govt Lab or NABL accredited laboratory: - (i) Colour (ii) odour (iii) taste (iv) pH value, (v) Turbidity (vi) TDS (vii) Total arsenic (viii) Silica (ix) Fluoride (x) Iron (xi) Magnesium (xii) Sulphate (xiii) Total Hardness (xiv) Total alkalinity (xv) Calcium (xvi) Conductivity (xvii) Chloride (xviii) Total Coliform and (xix) E Coli all as specified and as directed
Collection of water samples of STP located in different pockets of cantonment area in decontaminated sterilised bottles and testing of water samples for following essential parameters as per IS:10500- 2012 from Govt Lab or NABL accredited laboratory: - (i) Colour (ii) odour (iii) pH value ,(iv) Oil & Grease (mg / lit), (v) Nitrate (as NO3) mg/lit (vi)Total suspended solids (mg/lit) , (vii) Chemical Oxygen Demand (COD) mg/lit , Biological or Biochemical oxygen demand (BOD) mg/lit all as specified and as directed .
M&L for Periodical Repair/ Maint of Bleaching Powder doser including replacement of unserviceable parts and thorough cleaning. (Note: All spares required for repair will be measured and paid under separate item of this schedule as 'Supply only')
Supply only Rubber bladder suitable for 145 ltrs bleaching doser for Bleaching Powder Doser complete all as specified.
All as per item no. 17 but P.P. Funnel suitable for 145 ltrs bleaching doser.
All as per item no. 17 but Orifice Plate suitable for 145 ltrs bleaching doser
All as per item no. 17 but Drain Valve suitable for 145 ltrs bleaching doser
All as per item no. 17 but PVC pipe for Solution Dosing Line upto 3.0 mtr suitable for 145 ltrs bleaching doser
All as per item no. 17 but PVC Dose Control Valve suitable for 145 ltrs bleaching doser
All as per item no. 17 but Water Inlet Valve suitable for 145 ltrs bleaching doser
All as per item no. 17 but Solution Outlet Valve suitable for 145 ltrs bleaching doser
All as per item no. 17 but Air release Valve suitable for 145 ltrs bleaching doser
All as per item no. 17 but Solution Feed Valve suitable for 145 ltrs bleaching doser
Supply only Liquid O-Tolidine solution in sealed bottle of 50 ml of Make:- M/s Rankem/ M/s Qualigens
Supply of glass test tube of capacity 10 ml for chlorine check .
Supply fixing testing and commissioning of Microprocessor based circuit type water level device consist of seven segment 2 " LED display fitted in the control panel made of CRCA 16 SWG sheet with chemical grade powder coating to display water level in tank , SS304 grade level sensor pipe fitted in the tank by clamping at the bottom and the top of the tank consist of magnetic float and electronic switch for long life , the pump automatically switch OFF when the wate level in OH tank reaches the maximum level . Visual display with audio alarm on low water level in tank , Audio alarm on full tank with ON-OFF control , Toggle switch for manual run of pump when tank is full , heavy duty rubber coated wire (approx 100 mtrs ) for connecting the censor to the tank complete all as directed Make : Sathya Sai / SM Instrumentation/ Declibac
Lifting of defective submersible pumping set up to 35 HP capacity from deep well 300mm housing along with connected accessories such as column pipe of 150mm dia appx 30 m submersible cable, steel pipe, spider, sleeve, line shaft, nut, bolts etc complete all as specified and directed by Engr-In-Charge. [Note:- (i) All type of T & P, chain pulley & tripod etc required at site will be arranged by the contractor and rates for the same deemed to be included in the quoted rate (ii) The Contractor will start the lifting work with in minimum time after getting message verbally/telephonically by JE E/M/AGE E/M. (iii) A penalty of Rs. 500/- per day will be imposed on the Contractor for wilful delay by the Contractor will be imposed as per opinion of Engineer-in-Charge and amount will be deducted from the due payment of the Contractor]
Transportation including loading & unloading of defective submersible pumping sets 3 phase any make and capacity 25 to 35 HP from pump house to work shop for necessary repair and transporting back to the pump house including carefully loading & unloading of pump set after repair complete all as specified and directed by Engr-In-Charge.
Dismantling of defective submersible pumping set any make & model of capacity 25 HP to 35 HP, repairing the same including replacing old unserviceable parts and re-assembling and testing after repair complete all as specified and directed by Engr-In-Charge. [Note: (i) All the spares required for repair will be measured and paid seperately as supply only. (ii) Greasing of moving parts deemed to be included in the quoted rate]
Supply only CI/MS bowl (as per existing size) for submersible pump capacity 25 HP to 35 HP any make & model complete all as specified .
All as per item no. 33 but Stainless steel shaft with key
All as per item no. 33 but Gun Metal Bush
All as per item no. 33 but Stainless steel sleeve.
All as per item no. 33 but Sand Guard
All as per item no. 33 but Impeller lock with key
All as per item no. 33 but Neck ring (as per existing size and type)
All as per item no. 33 but Turning & polishing of Pump shaft (lathe work)
Supply only Stainless Steel thrust bearing for submersible motor of capacity 25 HP to 35 HP any make & model complete all as specified .
All as per item no. 41 but Carbon plate.
All as per item no. 41 but Gun Metal bush
All as per item no. 41 but Rubber bush
All as per item no. 41 but Upper housing
All as per item no. 41 but Lower Housing
All as per item no. 41 but Turning, polishing of Rotor & shaft (Lathe work)
M&L Rewinding of submersible motor capacity 30 HP to 35 HP any make & model with super enamelled copper wire of existing size including removal of existing burnt winding, cleaning of slots including packing material, connection and testing complete.
M&L for painting to pump set with two coat of synthetic enamel paint (grey colour) over a coat of red oxide primer after preparation of surface complete all as specified and directed by Engr-In-Charge.
Lowering, connecting, commissioning testing of repaired submersible set any make and capacity 25 HP to 35 HP 3 phase 415V into bore well 300/200mm with connected items such as column pipe approx 40 RM, properly connecting submersible cable etc complete all as specified and directed by Engr-In-Charge by Engineer-in-Charge. [Note:- (i) All type of T & P, chain pulley & tripod etc required at site will be arranged by the contractor and rates for the same deemed to be included in the quoted rate (ii) The Contractor will start the lifting work with in minimum time after getting message verbally/ telephonically by JE E/M/ AGE E/M. (iii) A penalty of Rs. 500/- per day will be imposed on the Contractor for wilful delay by the Contractor will be imposed as per opinion of Engineer-in-Charge and amount will be deducted from the due payment of the Contractor]
Complete servicing of Fire fighting pump set any make & model of capacity 60 HP including replacement of minor spares and testing after servicing complete all as specified and directed by Engr-In-Charge. [Note: (i) Greasing of moving parts deemed to be included in the quoted rate (ii) All type of T&P main switch ,electric multi meter/ tong tester for fault detecting , etc required at site will be arranged by the contractor and rates for the same deemed to be included in the quoted rate.
Supply only rubber packing 6mm thick consisting of 8/6" holes for 100mm to 150 mm dia column pipe complete all as specified and directed by Engr-In-Charge.
M&L Rewinding of 2-2.5 HP motor 3 phase 415 volt 50 Hz AC any make & model with super enamelled copper wire of existing size including removal of existing burnt winding, cleaning of slots including packing material, connection and testing complete.
Dismantling of defective Monoblock motor pump any make & model of capacity 2 -2.5 HP, repairing the same including replacing old unserviceable parts and re-assembling and testing after repair complete all as specified and directed by Engr-In-Charge. [Note: (i) All the spares required for repair will be measured and paid seperately as supply only. (ii) Greasing of moving parts deemed to be included in the quoted rate]
Supply only Motor Bearing for submersible pump capacity 2-2.5 HP any make & model complete all as specified.
All as per item no. 55 but gland packing
All as per item no. 55 but Packing paper
All as per item no. 55 but Water seal
All as per item no. 55 but Starting Coil
All as per item no. 55 but Motor housing & sleeve repairing on Lathe
All as per item no. 55 but Impeller Brass
M&L Rewinding of 5 HP motor 3 phase 415 volt 50 Hz AC any make & model with super enamelled copper wire of existing size including removal of existing burnt winding, cleaning of slots including packing material, connection and testing complete.
Dismantling of defective Monoblock motor pump any make & model of capacity 5 HP, repairing the same including replacing old unserviceable parts and re-assembling and testing after repair complete all as specified and directed by Engr-In-Charge. [Note: (i) All the spares required for repair will be measured and paid seperately as supply only. (ii) Greasing of moving parts deemed to be included in the quoted rate]
Supply only motor bearing for submersible pump capacity 5 HP any make & model complete all as specified
All as per item no. 64 but Gland packing
All as per item no. 64 but Packing paper
All as per item no. 64 but Water seal
All as per item no. 64 but Starting Coil
All as per item no. 64 but Motor housing & sleeve repairing on Lathe
All as per item no. 64 but Impeller Brass
M&L Rewinding of 10 HP motor 3 phase 415 volt 50 Hz AC any make & model with super enamelled copper wire of existing size including removal of existing burnt winding, cleaning of slots including packing material, connection and testing complete.
Dismantling of defective Monoblock motor pump any make & model of capacity 10 HP, repairing the same including replacing old unserviceable parts and re-assembling and testing after repair complete all as specified and directed by Engr-In-Charge. [Note: (i) All the spares required for repair will be measured and paid seperately as supply only. (ii) Greasing of moving parts deemed to be included in the quoted rate]
Supply only motor bearing for submersible pump capacity 10 HP any make & model complete all as specified
All as per item no. 73 nut Gland packing.
All as per item no. 73 nut Packing paper
All as per item no. 73 nut Water seal
All as per item no. 73 nut Starting Coil
All as per item no. 73 nut Motor housing & sleeve repairing on Lathe
All as per item no. 73 nut Impeller Brass
Periodical maintenance including complete servicing of Diesel Engine Generator set of 160 KVA capacity at Military Hospital of make: Kirloskar or any other make and connected accessories including replacement of oil /lubricant filter to keep the plant in running condition including routine maintenance complete all as specified and as directed. [Note: (i) The Contractor need to get the job done through authorised service centre/ agency of Kirloskar Oil Engine Ltd or any other OEM (Original Equipment Manufacturer) located near Faizabad. The cost thereof deemed to be included in the quoted rate. (ii) All Spare parts for routine maintenence will be measured and paid seperately under relevent items of this schedule as 'Supply Only' (iii) Labour charges for routine maintenance including properly dismantling of old parts deemed to be included in the quoted rate]
All as per item Ser No 80 here-in-before but of Diesel Engine Generator Set of 62.5/ 63 kVA capacity at Pump House No 1, 2, 3, 4, 5, 7, 8, 9, 10, 11, 12, STP Himachal Niwas, STP Kandahar Line, Signal Centre, Amn Dump, Trolly Mounted
All as per item Ser No 80 here-in-before but of Diesel Engine Generator Set of 40 kVA capacity at Records
All as per item Ser No 80 here-in-before but of Diesel Engine Generator Set of 15 kVA capacity at Stn HQ
Supply only cut out for routine maintenance of Alternator of DG Set 160 KVA
All as per item Ser No 84 but Rectifier Assembly
All as per item Ser No 84 but Brush Box Assembly
All as per item Ser No 84 but Bearing
All as per item Ser No 84 but Oil seal
All as per item Ser No 84 but Field Coil
All as per item Ser No 84 but Lubricant oil filter for DG set 160 KVA
All as per item Ser No 84 but Fuel filter (Pre) for DG set 160 KVA
All as per item Ser No 84 but Fuel filter (Micro) for DG set 160 KVA
All as per item Ser No 84 but Air filter for DG set 160 KVA
All as per item Ser No 84 Hose : Water Pump inlet to Radiator outlet for DG set 160 KVA
All as per item Ser No 84 Hose :Pipe to Water Pump for DG set 160 KVA
All as per item Ser No 84 Hose : Pipe to Diesal tank for DG set 160 KVA
All as per item Ser No 84 Hose pipe clip with nut
All as per item Ser No 84 Terminal block for DG set 160 KVA
Supply only Cut out for routine maintenance of Alternator of DG Set 15-62.5 KVA
All as per item no. 99 but rectifier assembly
All as per item no. 99 but Brush Box Assembly
All as per item no. 99 Bearing
All as per item no. 99 Oil seal
All as per item no. 99 Field Coil
All as per item no. 99 Lubricant oil filter
All as per item no. 99 Fuel filter (Pre)
All as per item no. 99 Fuel filter (Micro)
All as per item no. 99 Air filter
All as per item no. 99 Hose : Water Pump inlet to Radiator outlet
All as per item no. 99 Hose :Pipe to Water Pump
All as per item no. 99 Hose : Pipe to Diesal tank
All as per item no. 99 Hose pipe clip with nut
All as per item no. 99 Terminal block
Supply only Coolant for DG Set
Supply only Lube Oil for DG Set of make Koel Care Premium Genuine
Supply only lead acid battery 12 volt 160 Ah including initial charge complete all as directed by Engr-In-Charge .
M&L for Automatic Voltage Regulator for DG Set of capacity 15 to 62.5/ 63 kVA including taking out of old one complete all as directed by Engr-In-Charge.
M&L for Calibration of Fuel Injection Pump including properly dismantling and transporting to service center/workshop for over hauling/ calibration and refixing on DG Set after calibration for DG Sets of capacity 160 kVA including taking out of old one and with replacement of following items all as directed by Engr -in charge : a) Element - 06 Nos b) D.V - 06 Nos c) T.R.B - 06 Nos d) Bearing - 02 Nos e) C.R - 01 Nos f) C.R Bush - 02 Nos g) Ball Bearing - 01 Nos h) F.P.P - 01 Nos i) F.P Kit - 01 Nos j) Pressure Bolt - 06 Nos k)Nozzle seal - 02 Nos l) Nozzle setting - 06 Nos & with all other neessary items .
All as per item Ser No 118 above but for DG Sets of capacity 62.5/ 63 kVA
All as per item Ser No 118 above but for DG Sets of capacity 40 kVA
All as per item Ser No 118 above but for DG Sets of capacity 15 kVA
M&L for Banjo Bolt M 14 x 1.5 including taking out of old one.
M&L for Flexible fuel pipe type 7.5 14 x 14 B 700 PB of make: Kirloskar or equivalent make as approved by GE including taking out of old one.
M&L for Expansion bellow suitable for 62.5 kVA DG Set of make:Kirloskar or equivalent make as approved by GE including taking out of old one.
M&L for Starter Ring suitable for 40 kVA DG Set of Kirloskar or equivalent make as approved by GE taking out of old one.
M&L for Starter Ring suitable for 62.5 kVA DG Set of make:Kirloskar or equivalent make as approved by GE including taking out of old one.
M&L for Fuel Pump mounted STOP solenoid switch suitable for 62.5-63 kVA DG set of make: Kirloskar or equivalent make as approved by GE including taking out of old one.
M&L for Fan Belt suitable for 62.5 kVA DG set ofKirloskar or equivalent make as approved by GE including taking out of old one.
M&L for servicing of radiator including cleaning and testing of leakages for DG set of capacity 15-62.5 KVA complete all as specified and as directed . [Note: - In case of leakages found during servicing, the same should be measured and paid separately ]
Dismantling the radiator and transporting to workshop, repair of all leakage and transporting back and refitting in original position and testing for DG set of capacity 15-62.5 KVA all as specified and as directedand
M&L for Carefully dismantling the fuel tank and transporting to workshop, repair of all leakage, cleaning and transporting back and refitting in original position and testing after completion for DG set of capacity 62.5/ 63 kVA all as specified and as directed including taking out of old one.
M&L for Carefully cleaning of fuel tank for DG set of capacity 62.5/ 63 kVA all as specified and as directed including taking out of old one.
M&L for Carefully dismantling the self starter of DG set capacity 15-62.5 KVA and transporting to workshop and reffiting back after repair with replacement / repair .
Supply only carbon bush with spring for repair of self starter
All as per item Ser No 134 above but GM Bush set
All as per item Ser No 134 above but Bendex Pinion
All as per item Ser No 134 above but Solenoid switch
All as per item Ser No 134 above but Armature Rewinding
All as per item Ser No 134 above but Field Coil Set
M&L for rectification of leakage from GI Pipe line of size 80mm bore joints including excavation, returning and filling etc incl fittings like unions, sockets, bends, elbows, tees, nipples etc as required complete all as specified
All as per item Ser No 140 above but 50mm bore
All as per item Ser No 140 above but 40mm bore
All as per item Ser No 140 above but 25mm bore
All as per item Ser No 140 above but 20mm bore
S&F gun metal globe or gate valve 'ISI marked' of size 20mm bore with iron wheel head screwed both end for iron pipe all as per latest IS specifications.
All as per item Ser No 145 above but 25mm bore
All as per item Ser No 145 above but 40mm bore
All as per item Ser No 145 above but 50mm bore
S&F connection & testing sluice valve of size 80mm bore 'ISI marked' both ends flanged and drilled cast iron body class PN-1.6 conforming to IS-14846/2000 complete with gun metal spindle including necessary nut bolts and gasket etc for fixing, including taking out unserviceable sluice valve/ butterfly valve from water mains complete all as specified and directed [Note: For sluice valves fixed with pillars of over head tank, breaking of RCC/lead/ flange joints and repairing the same after fixing of valve deemed to be included in the quoted rates]
All as per item Ser No 149 above but 100mm bore
All as per item Ser No 149 above but 150mm bore
M&L for rectification of leakage from CI Pipe line of joints including excavation in mud/soil and coucking with pig lead , returning filling of size 150mm bore complete all as directed
All as per item Ser No 152 above but 100mm bore
All as per item Ser No 152 above but 80mm bore
M&L Earthing complete with galvanised steel earth plate electrode 600 X 600 X 6mm thick buried directly in ground vertically to a depth not less than 2.25 meters deep below ground level with top edge of the earth plate not less than 1.5 meters deep below normal ground level, connected with and including galvanised iron strip of size 25 x 4mm connected to main test point as directed as earthing lead by means of nuts, bolts and washers of galvanised iron protected by 40mm dia (medium grade) GI tubing, funnel, wire mesh, 20mm bore GI tubing (light grade) watering pipe, including concrete pit in PCC (1:3:6) type C-1, precast RCC (1:2:4) type B-1 cover slab of size 350 x 350 x 50mm reinforced with 8mm dia TMT bars @ 15cm c/c in both ways and 10mm dia MS handle (01 No) of suitable size for lifting of cover slab, charcoal and salt in alternate layers including necessary excavation and earth work in soft/loose soil all as shown in Electric plate No 3 of SSR Part-I and testing on completion complete all as specified and directed by Engr-in-Charge.
M&L for replacing of gland packing,nut-bolts and washer of sluice valve of 80mm bore
All as per item Ser No 156 above but 100mm bore
All as per item Ser No 156 above but 150mm bore
M&L for replacing of gun metal check nut of sluice valve of 80mm bore
All as per item Ser No 159 above but 100mm bore
All as per item Ser No 159 above but 150mm bore
M&L for replacing of existing size brass spindle of sluice valve of 80mm bore
All as per item Ser No 162 above but 100mm bore
All as per item Ser No 162 above but 150mm bore
S&F Socket 'ISI marked' for iron pipe all as per latest IS specifications of size 15mm bore
All as per item Ser No 165 above but 20mm bore
All as per item Ser No 165 above but 25mm bore
S&F Nipple of length 6'' 'ISI marked' for iron pipe all as per latest IS specifications of size 15mm bore
All as per item Ser No 168 above but 20mm bore
All as per item Ser No 168 above but 25mm bore
All as per item Ser No 168 above but 40mm bore
All as per item Ser No 168 above but 50mm bore
S&F Nipple of length 4'' 'ISI marked' for iron pipe all as per latest IS specifications of size 15mm bore
All as per item Ser No 173 above but 20mm bore
All as per item Ser No 173 above but 25mm bore
All as per item Ser No 173 above but 40mm bore
All as per item Ser No 173 above but 50mm bore
S&F Union 'ISI marked' for iron pipe all as per latest IS specifications of size 20mm bore
All as per item Ser No 178 above but 25mm bore
All as per item Ser No 178 above but 40mm bore
All as per item Ser No 178 above but 50mm bore
S&F Long 'ISI marked' for iron pipe all as per latest IS specifications of size 15mm bore
All as per item Ser No 182 above but 20mm bore
All as per item Ser No 182 above but 40mm bore
All as per item Ser No 182 above but 50mm bore
S&F Pluck 'ISI marked' for iron pipe all as per latest IS specifications of size 15mm bore
All as per item Ser No 186 above but 20mm bore
All as per item Ser No 186 above but 25mm bore
All as per item Ser No 186 above but 40mm bore
All as per item Ser No 186 above but 50mm bore
All as per item Ser No 186 above but 80mm bore
S&F Elbow 'ISI marked' for iron pipe all as per latest IS specifications of 15mm bore
All as per item Ser No 192 above but 20mm bore
S&F 'Tee' of size 20mm 'ISI marked' for iron pipe all as per latest IS specifications
S&F Reducer of size 15x20 mm 'ISI marked' for iron pipe all as per latest IS specifications
S&F CPVC pipe schedule-40 with all fittings and fixed complete to wall/Ceiling or laid in floor/trenches and connection taken from GI/CI/DI fitting material including metal clamp with screw etc. complete all as specified and directed for 80mm bore sizes make: ISI Marked best quality inclusing Taking out steel water tubing including fittings complete all as specified and directed for 80mm bore size ( Note- Excavation & earth work shall be measured and paid separately)
Excavation in trenches n.exc. 1.5 mtr wide and n.exc. 1.5 mtr in depth for laying / taking out water supply pipe line in soft/loose soil, taking out excavated material,forming bottom etc complete all as specified.
Returning filling in including,spreading ,levelling watering and well ramming in layer in n.exc 25 cm in soft/lose soil complete all as specified.
Removing excavated material to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above starting point as in soft/loose soil complete all as specified.
S&F Unplasticised PVC pipes Sch 40 of fixed complete to walls, ceilings or in floors etc., any type of pipe for 15mm bore sizes make: ISI Marked best quality including taking out steel water tubing for 15mm bore size including fittings complete all as specified.
Super Automobiles
His And Her Enterprises
M/s A.KUMAR ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .