| 3 | L3₹42.6 L+₹5.8 L (15.7%)Rejected-AOC 39 40 DASHMESH MARKET CIVIL GURUDWARA LINE PORT BLAIR 744 101 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L3 | Rejected-AOC Not Lowest | |
| 4 | L4₹43.5 L+₹6.7 L (18.2%)Rejected-AOC HOUSE NO 2 4 136 LINGREDDY MANSION BLOCK NO IV OPP HANUMAN TEMPLE TADBUND SECUNDERABAD 500009 | SECUNDERABAD | HYDERABAD | TELANGANA | 500009 | L4 | Rejected-AOC Not Lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
27 Jul 2020, 6:00 pmClosed
GE UTILITY SECUNDERABAD
GE UTILITY, MUDFORT, SECUNDERABAD-500003
REPAIR RENEWAL OF WATER SUPPLY DISTRBUTION SYSTEM, REPLACEMENT OF CONTROL VALVE, VALVE POINTS WITH CONNECTED ITEMS AND LT OH Line, LTCable, LT Panel, Street Lights and allied works AT CDA DAD. PAO OR AOC, PAO OR EME RUDRAMMA GUEST HOUSE AND CERTAI
2020_MES_357107_1
GE(U)/SEC/TOKEN/22 OF 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
SECUNDERABAD
As per NIT
6 documents required · 6 mandatory
₹500
GE UTILITY SECUNDERABAD
₹90,000
Yes
5 Aug 2020
30 Jun 2020
29 Jul 2020
30 Jun 2020
27 Jul 2020
15 Jul 2020
Amount
Attending repair/rectification of leakages to water supply distribution lines 20 mm bore to 25 mm bore GI/PPR tubing with provision of necessary excavation, returning and filling in as required, tightening of loose joints of union, elbow, sockets etc, threading if required including replacement of GI unions/sockets/nipples as required at site complete all as specified and directed.
All as per item No 1 above but for GI tubing 40 mm bore to 50 mm bore
All as per item No 1 here-in-before but for GI tubing 80 mm bore to 100 mm bore.
Attending routine compaints of external water supply including rectification of minor defects by taking down of existing GI/PPR tubing up to 25 mm bore, cutting/threading and making joints and cleaning for any blockages, opening of float valve of service tanks, cleaning and fixing the same in its position, replacement of jumper valve/ packing sheet of gate valve and including replacement of GI unions/sockets/nipples etc as required at site complete all as specified and directed.
All as per item No 4 above but for GI tubing 40 mm bore to 50 mm bore.
M&L for attending break down of water supply pipe line and repair to CI/DI/PPR water mains of size 80 mm to 300 mm bore at a given notice including necessary excavation in mud, in any type of soil by manual or using special T&P such as JCB etc. De-watering from the trenches by using pump sets, rectification of leakages, fixing of CI specials such as collars, bends/tail peaces etc and making joints complete all as specified and as directed. Note:- CI specials, lead Joints, D-Joints, Clamp joints, DI/CI Pipe etc shall be measured and paid under respective items of sch 'A'.
Notes for Sl item No 1 to 6 :- (a) The contractor will be alloted complaints at MES complaint cell on requirement basis on all working days including Sundays and holidays and sufficient tradesman / resources will be deployed by him/her for completion of day to day comaplaints within 12 hours from the time of reporting. Any delay beyond above mentioned time limit without intimation of genuine cause, penalties will be recovered twice of the quoted rate for each un-attended complaint. (b) A detailed log book of complaints with completion/non-completion remarks from users/MES will be maintained by the contractor and the same will be updated on daily basis in consulatation with JE E&M/Engr-in-Charge. (c) The contractor will make suitable arrangment for emergency complaints and will notify authorised representive/Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond stated time limit set for disposal of complaint. In case of any dispute the decision of accepting officer will be final and binding in this regard.
(d) The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints. (e) The quoted rate is deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Military station at Secunderabad. (f) The contractor will maintain location wise record of each spare/fittings utilized as per inventry format given by AGE E/M, Secunderabd and the same shall be submitted to E/M No II store yard on requirement basis. (g) The stationery required for the job work such as complaint slip books, gate pass book, job card and T&P shall be arranged and maintained by the contractor. (h) The cost of excavation / earth work and repairs to damaged roads, LT UG/HT cables, existing structure etc shall be deemed to be included in the quoted unit rate and no extra payment shall be allowed on this account. (j) Spares/GI fittings required to be replaced and shall be measured and paid separately under respective items.
S&F Insulator Pin type of size 100 mm height, 65 mm dia for 1100 Volt grade, porcelain, vitreous, white, brown or green including one galvanized MS Spindle, two GI washers and one GI washers including disconnecting/taking out old existing unsv insulators complete all as specified and directed.
S&F Insulator Shackle type of size 100 mm height, 115 mm dia for 1100 Volt grade, porcelain viterous, white, brown or green including galvanised mild steel straps of size 31x5 mm, washers, insulator bolts of size 14 mm and nuts including disconnecting/taking out old existing unsv insulators complete all as specified and directed.
S&F loop type insulator type of size 100 mm height, 115 mm dia for 1100 Volt grade, porcelain viterous, white, brown or green including galvanised mild steel straps of size 31x5 mm, washers, insulator bolts of size 14 mm and nuts including disconnecting/taking out old existing unsv insulators complete all as specified and directed.
Taking up or down steel tubing and connections, including cleaning the pipes free from scaling for for re-fixing or removal complete with all fittings and connections of the following sizes :-
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
100 mm dia
Refixing of old steel tubing and connection in new or old position including fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in trenches and testing for leakages complete all as specified and directed for the following sizes:-
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
100 mm dia
Notes for item No 11.01 to 11.07 :- (a) Excavation and Earth work shall be measured and paid separately.
Refixing of old steel tubing and connection in new or old position including fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in floors, walls and ceilings and testing for leakages complete all as specified and directed for the following sizes:-
15 mm dia
20 mm dia
25 mm dia
Supply and laying steel water tubing medium grade, galvanised with all fitting, laid in trenches and testing for leakages complete all as specified and directed for the following sizes:-
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
100 mm dia
Notes for item No 13.01 to 13.07 :- (a) Excavation and Earth work shall be measured and paid separately.
Supply and laying steel water tubing medium grade, galvanised with all fitting, fixed to wall and ceilings or laid in floor and testing for leakages complete all as specified and directed for the following sizes:-
15 mm dia
20 mm dia
25 mm dia
Taking up or down PPR pipe and connections, including cleaning the pipes free from scaling for for re-fixing or removal complete with all fittings and connections of the following sizes :-
32 mm dia
50 mm dia
110 mm dia
Refixing of old PPR Pipe and connection in new or old position including fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in trenches and testing for leakages complete all as specified and directed for the following sizes:-
32 mm dia
63 mm dia
110 mm dia
Notes for item No 16.01 to 16.03 :- (a) Excavation and Earth work shall be measured and paid separately.
Refixing of old PPR Pipe and connection in new or old position including fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in floors, walls and ceilings and testing for leakages complete all as specified and directed for the following sizes:-
32 mm dia
63 mm dia
Supply, laying and testing of polypropylene random copolymer (PP-R) (PN-10-SDR-11) 3 layer pipes ISI marked as per IS-15801, UV stabilized and anti microbial fusion welded having thermal stability for hot and cold water supply all PPR plain and brass thread polypropylene random fittings laid in trenches of following sizes including all fittings. Make : SFMC/KPT/WETFLOW/SAFE.
32 mm dia
63 mm dia
110 mm dia
Notes for item No 18.01 to 18.03 :- (a) Excavation and Earth work shall be measured and paid separately.
Supply, laying and testing of polypropylene random copolymer (PP-R) (PN-10-SDR-11) 3 layer pipes ISI marked as per IS-15801, UV stabilized and anti microbial fusion welded having thermal stability for hot and cold water supply all PPR plain and brass thread polypropylene random fittings fixed complete to walls, ceilings or in floors etc of following sizes including all fittings. Make : SFMC/ KPT/ WETFLOW/ SAFE.
32 mm dia
63 mm dia
Taking up unserviceable/ defective CI/DI/MS water mains (including all fitting ) with spigot/ socketed / flanged ends including disconnecting pipes and fittings in any position complete all as specified and directed for the following sizes:-
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
Refixing of old CI/DI/MS Pipe and connection in new or old position including fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in trenches and testing for leakages complete all as specified and directed for the following sizes:-
80 mm dia
100 mm dia
150 mm dia
200 mm dia
Notes for item No 21.01 to 21.05 :- (a) Excavation and Earth work shall be measured and paid separately.
S&F ductile iron pressure pipes, class K9, centrifugally cast with spigot and socket ends as per following conforming to IS 8329/2000 with cement mortar lining inside the pipes with outside zinc coating suitable for push-on-joint (rubber gasket D jointing) in any length including DI specials as required at site confirming to IS 8329/2000 and all jointing materials and making good for disturbed surfaces of roads, path ways etc while laying the pipe line at site, site clearance for the route of pipe line, welding, cutting the existing CI/DI/MS pipe line of any size up to 400 mm dia for inserting branch connections etc complete all as specified and directed for the following sizes:- Notes:- (a) Lead Joints / D-Joints will be measured and paid separately. (b) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the MES deparatment if required. (c) Contractor is responsible for repair/replacement of any damages to the existing structures, Under Ground HT/LT/OFC Cables etc during the course of execution.
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
Notes for item No 22.01 to 22.05 :- (a) Excavation and Earth work shall be measured and paid separately.
Cutting existing CI pipe line for insertion of new tees, collars for branch connections complete all as specified and directed for the following sizes:- Note: CI /DI specials, Joints and Earth work shall be measured and paid sperately under relevant items of this schedule.
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
Supply only GI fittings 15 mm bore, medium grade, ISI marked, smooth finished and make embossed on fittings complete all as specified and directed for the following fittings:-
Union
All equal Tee
Socket
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Elbow
Hex Nipple
All as per item No 24 above but for 20 mm bore.
Union
All equal Tee
Reducer Tee 20 x 20 x 15 mm
Socket
Reducer Socket 20 x 15 mm
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Reducer Elbow 20 x 15 mm
Elbow
Hex Nipple
All as per item No 24 above but for 25 mm bore.
Union
All equal Tee
Socket
Reducer Socket 25 x 20 mm
Reducer Socket 25 x 15 mm
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Elbow
Reducer Elbow 25 x 20 mm
Reducer Elbow 25 x 15 mm
Reducer tee 25mm x 25 mm x 20mm
Reducer tee 25mm x 25 mm x 15mm
Hex Nipple
All as per item No 24 above but for 40 mm bore.
Union
All equal Tee
Socket
Reducer Socket 40 x 25 mm
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Elbow
Reducer elbow 40mm x 25mm
Reducer tee 40mm x 40mm x 25mm
Reducer tee 40mm x 40mm x 20mm
Hex Nipple
All as per item No 24 above but for 50 mm bore.
Union
All equal Tee
Socket
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Reducer 50mm x 40mm.
Reducer 50mm x 25mm.
Elbow
Reducer elbow 50mm x 40mm
Reducer elbow 50mm x 25mm
Reducer tee 50mm x 50 mm x 40mm
Reducer tee 50mm x 50 mm x 25mm
Reducer tee 50mm x 50 mm x 20mm
Hex Nipple
All as per item No 24 above but for 80 mm bore.
Union
All equal Tee
Socket
Reducer 80mm x 50mm.
Reducer 80mm x 40mm.
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Elbow
Reducer elbow 80mm x 50mm
Reducer elbow 80mm x 40mm
Reducer tee 80mm x 80mm x 50mm
Reducer tee 80mm x 80mm x 40mm
Hex Nipple
All as per item No 24 above but for 100 mm bore.
Union
All equal Tee
Socket
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Reducer 100mm x 80mm.
Reducer 100mm x 50mm.
Reducer 100mm x 40mm.
Elbow
Reducer elbow 100mm x 80mm
Reducer elbow 100mm x 50mm
Reducer elbow 100mm x 40mm
Reducer tee 100mm x 100mm x 80mm
Reducer tee 100mm x 100mm x 50mm
Reducer tee 100mm x 100mm x 40mm
Supply and fix in replacement of unserviceable Gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes and fixed complete all as specified and directed for the following sizes:-
15mm dia bore
20mm dia bore
25mm dia bore
40mm dia bore
50mm dia bore
Note for Sl item No 31.01 to 31.05, Make : Zoloto
Supply and fix in replacement of unserviceable ball brass valves, high pressure with polythene float and fly nut alongwith socket/reducer of suitable size, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed for the following sizes:-
20mm dia bore
25mm dia bore
M&L for dismantling of defective sluice valve for repairs, such as repacking stuffing box of sluice valve spindle, refacing, grinding, stuffing and threading of spindle, replacement of worn out check nut, repairs to gate assembly etc, replacement of jointing materials such as rubber sheets, nuts, bolts, washers and gland rope etc and refixing in its original position, testing on completion complete all as specified and directed for the following sizes:-
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
S&F CI specials such as bends (any type, radius or angle) tapers any type (Straight, bend, increase, decrease or double socket etc) tee pieces, single 'Y' branch, double branch cross (all sockets, socket and spigots, collars, cap plugs etc up to 150 mm bore complete all as specified and directed.
All as per item No 34 above but for 200 mm bore to 300 mm bore.
Burning out lead joint in position for following sizes of CI/DI pipe, removing old lead complete all as specified and directed :-
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
M&L for run lead joint for CI pipe/DI pipe including spun yarn etc for spigot and socket pipes and fittiings complete all as specified and directed for the following bore of pipes:-
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
S&F in repairs cast iron detachable (D-Joints) heavy duty, ISI marked, split type with long collar, suitable rubber rings, bolts, nuts and washers etc suitable for MS/CI/DI/GI /PVC pipes of following sizes all as specified and as directed:- Notes:- (a) Excavation and Earth work shall be measured and paid separately. (b) CI/GI/MS pipe for insertion will be measured and paid separately under relevant item of this schedule. (c) Quoted rate is deemed to be inclusive of necessary T&P for cutting the pipe line, Pump sets for De-watering, JCB for Excavation (if required) etc and no extra payment shall be admissible on this account.
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
S&F in replacement of Cast Iron sluice valves flanged ends stem of SS (AISI410) & Bronze (Gun Metal) working parts IS : 14846 both ends flanged with clamps and check nuts, operating wheel etc, non rising type K504, class PN 1.6 including jointing materials connecting and testing complete all as specified and directed.
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
S&F in replacement of Cast Iron sluice valves flanged ends stem of SS (AISI410) & Bronze (Gun Metal) working parts IS : 14846 both ends flanged with clamps and check nuts, operating wheel etc, rising type K506, class PN 1.6 including jointing materials connecting and testing complete all as specified and directed.
200 mm Dia
Cutting the existing road straight by manual, depth and width not less than 30 cm for pipes up to 100 mm dia and 60 cm for pipes from 150 mm to 150 mm dia and 75 cm for pipes above 250 mm dia and filling back with excavated soil up to 75 % road portion and 25 % shall be made with cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate complete all as specified and directed.
Construction of valve chamber of size 900 x 900 mm (Internal size) 900 mm deep with 200mm thick PCC block masonary walls built in CM 1:6 over 100 mm thick foundation concrete in PCC 1:4:8 type D2, (Using 40 mm graded coarse aggregate) with 100 mm off set, 15mm thick complete internal plaster and external plaster up to a depth of 15 cm below GL in CM (1:6), 3 mm thick MS sheet cover, double door welded to 50 mm x 50 mm x 6mm MS angle frame fixed with hold fasts in PCC 1:2:4 type B1 coping 50 mm thick in PCC (1:2:4) type B-1, 20mm x 6mm flat iron hinges with locking arrangement including lock sixty five mm, brassd and keys(Godrej/Shell), MS handles and applying two coats of synthetic eanmel paint over a coat of red oxide zinc chrome primer to all steel surfaces including excavation & earth work in any type of soil /soft disintegrated rock and disposal of surplus soil to a distance not exceeding 50 Mtr complete all as specified and directed
Supply and fixing PP-R Pipe fittings and accessories 32 mm bore, smooth finished and make embossed on fittings complete all as specified and directed for the following fittings:-
Reducer Socket 32 x 25 mm
Socket
All equal Tee
Union
Gate Valve
All as item No 52 above but 63 mm bore :-
Reducer Socket 63 x 32 mm
Socket
All equal Tee
Reducer Tee 63 x 63 x 32 mm
Union
Gate Valve
All as item No 52 above but 110 mm bore :-
Socket
All equal Tee
M&L for replacement of cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including welding, bending cold or hot, drilling holes for hinged, in any shape or size as indicated for valve chamber top cover, 4 mm thick MS sheet cover fixed on 40 mm X 40 mm X 6 mm thick angle iron frame with locking arrangement, mild steel handle, and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.
Supply and lay Pipes MS black ERW Steel including specials having nominal dia 80 mm of thickness 9.0 mm as per IS 3589 - 2001, Grade - 330 with plain ends and specials by welding, leak testing of line laid in trenches / floors/ walls /ducts including taking down of old unserviceable MS pipe all as specified and directed. Note: Quoted rate is inclusive of welding and cutting.
All as per Item No. 48 above but for 100 mm dia
All as per Item No. 48 above but for 150 mm dia
All as per Item No. 48 above but for 200 mm dia
Cleaning throroughly existing DI/CI/MS pipe line at raising / delivery line of OHT / supply line by removing any material struck inside the pipe line and make the line free from constraints to flow for the size of 150/200mm dia including taking down and removing of existing pipe line from current location including joints / valves / specials etc and refixing in the same position all as specified and directed. Note : (i)Rate quoted by the contractor inclusive of all arrangement as required includind scaffolding for disconnecting of pipe and rejointing the same (ii)All required safety equipments (Gumboot, helmets,safety belts,Safety googles, torch light etc) and necessary insurance for safety of working staff to execute the work is responsibility of the contractor. quoted for that is deemed to be inclusive in the unit rate.
Renewal of single phase preventor cum low level water guard suitable for 4 to 7.5HP submersible pump set complete all as directed by Engineer-in-Charge.
Renewal of DOL starter suitable for 5/ 7.5 HP submersible pump set of 3 phase including necessary internal wiring with suitable copper wire including testing and commissioning complete all as directed by Engineer-in-Charge.
Taking out unserviceable GI socket from 50 mm column pipe and S&F new GI socket 50mm (ISI marked) long type, heavy duty suitable for the column pipe complete all as directed by Engineer-in-Charge.
Cutting the existing damaged threading of GI column pipe 50 mm dia and re-threading on lathe machine complete all as directed by Engineer-in-Charge.
Removing old unserviceable column pipe as obtained from lowering of submersible pump set and S&F new GI column pipe 50mm dia, heavy duty, ISI marked, 3 metre length each, both ends machine threaded with long threaded socket complete all as directed by Engr-in-Charger.
Removing unserviceable PVC water proof cable of any size as obtained from lowering of submersible pump set and S&F new PVC water proof copper cable of size 3 core 2.5 sqmm suitable for submersible pump set complete all as directed by Engr-in-Charge.
M&L for cable joint for water proof cable of 3 core 2.5 /4.0 sqmm flat copper cable including testing and commissioning complete all as directed by Engineer-in-Charge.
Removing unserviceable PVC water proof cable of any size as obtained from lowering of submersible pump set and S&F new PVC water proof copper cable of size 3 core 4.0sqmm suitable for submersible pump set complete all as directed by Engr-in-Charge.
M&L for cable joint for water proof cable of 3 core 4.0 sqmm flat copper cable including testing and commissioning complete all as directed by Engineer-in-Charge.
Renewal of water guard cathode including copper cable of 1.5 Sqmm upto the depth of 70 mtrs complete all as directed by Engr-in-Charge.
S&F Borewell casing cover 200 to 300 mm
M&L for flushing of the existing borewells of size 150 mm dia upto 350 feet depth by drilling machine by mechanically method into the above well connected to a pneumatic compressor after taking out the submersible pumpset with necessary hoisting equipment and flushing the bore well complete with compressor air and flushing bore well till discharge of fresh water is obtained subject to the entire satisfaction of Engr-in-charge and lowering down the submersible pump set in position complete all as directed by Engineer-in-charge.
M&L for flushing of the existing borewells of size 150 mm dia above 350 feet and upto 650 feet depth by drilling machine by mechanically method into the above well connected to a pneumatic compressor after taking out the submersible pumpset with necessary hoisting equipment and flushing the bore well complete with compressor air and flushing bore well till discharge of fresh water is obtained subject to the entire satisfaction of Engr-in-charge and lowering down the submersible pump set in position complete all as directed by Engineer-in-charge.
Taking out submersible pumpset of any capacity and type from the borewell of depth not exc 200 metres for carrying out repairs including cleaning and applying one coats of anti corrosive paint and lowering the same in position and commissioning after carrying out the repairs as required complete all as directed by Engineer-in-Charge. Note:- i) Rewinding of burnout winding of motor,supply of parts repairs to pumpset will be measured under relevant item of this schedule
Repairs to submersible motor electric driven up to 5 HP capacity of any make and type by rewinding of the motor with same gauge and weight of PVC insulated copper wire and other required insulating materials and renewal of thrust plate, bearing , reassembling, including testing and commissioning complete all as directed by Engineer-in-Charge.
Repairs to submersible motor of electric driver, above 7.5 HP up to 10 HP capacity of any make and any type by rewinding the motor with same gauge and weight of PVC insulated copper wire and other required insulating materials and renewal of thrust plate, bearing ,reassembling, including testing and commissioning complete all as directed by Engineer-in-Charge.
Repairs to submersible pumpset upto 18 stage, replacing the worn out spare parts with new spare parts overhauling and greasing including testing complete all as directed by Engr-in-Charge. Note:- spare parts as required for functioning of of PUMP set shall be included in the quoted rate
Disconnecting and removing the water and electric connections care fully from the existing Burnt centrifugal pump sets of capacity 5 / 7.5 HP and shifted to workshup for rewinding with same guage of copper wire , replacement of bearing , thrust plate etc as required for proper functioning of the centrifugal motor anf refix the same on its own position along with all electric and water connection complete all as directed. Note : The spares required for repair the pump sets and rewinding of motors deemed to be included in the quoted rate.
Supply and installation CPRI approved pump starter electric control panel board, for INdoor use, DOUBLE door ( BOTH DOOR HAVING LOCKING ARRANGEMENT INCLUDING 2 NOS GODREJ 7 LIVER LOCK) dust & vermin proof floor mounted made out of CRCA steel sheet of 2 mm thick angle iron legs of size50x50x5mm, having electrolytic high conductivity insulated bus bar made out of aluminium strips of rating 100 Amps for 3 phase, 415 Volts, 50 C/S 4 wire system, with cable enty jprovision, with suitable lugs gland, voltmeter, Ammeter and phase indicator complete, duly painted with two coats of stove enameled power coated paint over a coat of red oxide primer complete all as including necessary PCC work of height 300 cm from the ground level including disconnecting/taking out old existing unsv pump panel complete all as specified and directed of the following( Leg of the panel should not be less than 0.75 M and size of the panel should not be less than 70CmX70CMX30CM)) :-
INCOMMING :- (a) MCCB, 4 pole, 415 Volt, 40 Amps, 16 KA - 01 No (b) 3 Phase LED Voltmeter, class - 0.5 - 01 No (c) 3 Phase LED Ammeter, class -0.5 - 01 No (d) LED Indicator lamp in three colour RYB - 01 Set OUTGOING :- (a) MCCB, 3 pole, 10 KA c Curve 415 volts, 25Amps -02 No (b) DOL starter in sheet enclosure type MK-1, Motar rating AC-3 duty, 415 volts, 50 Hz suitable FOR 7.5 HP relay max rang 15-25 Amps-02 No. (c) Single hase preventor realy type Sz% (6wire), 415 volts -01 No
Supply and installation CPRI approved pump starter electric control panel board, for out door use, DOUBLE door ( BOTH DOOR HAVING LOCKING ARRANGEMENT INCLUDING 2 NOS GODREJ 7 LIVER LOCK) dust & vermin proof floor mounted made out of CRCA steel sheet of 3.15 mm thick angle iron legs of size50x50x5mm, having electrolytic high conductivity insulated bus bar made out of aluminium strips of rating 100 Amps for 3 phase, 415 Volts, 50 C/S 4 wire system, with cable enty jprovision, with suitable lugs gland, voltmeter, Ammeter and phase indicator complete, duly painted with two coats of stove enameled power coated paint over a coat of red oxide primer complete all as including necessary PCC work of height 300 cm from the ground level including disconnecting/taking out old existing unsv pump panel complete all as specified and directed of the following( Leg of the panel should not be less than 0.75 M and size of the panel should not be less than 70CmX60CMX30CM)) :-
INCOMMING :- (a) MCCB, 4 pole, 415 Volt, 40 Amps, 16 KA - 01 No (b) 3 Phase LED Voltmeter, class - 0.5 - 01 No (c) 3 Phase LED Ammeter, class -0.5 - 01 No (d) LED Indicator lamp in three colour RYB - 01 Set OUTGOING :- (a) MCCB, 3 pole, 10 KA c Curve 415 volts, 32 Amps -01 No (b) DOL starter in sheet enclosure type MK-1, Motar rating AC-3 duty, 415 volts, 50 Hz suitable FOR 7.5 HP relay max rang 15-25 Amps-01 No. (c) Single hase preventor realy type Sz% (6wire), 415 volts -01 No
Material labour for removing submersible pump motor set of capacity up to 10 HP stuck in side the borewell of depth up to 200 meter including necessary Compressoe ,machinaries , removing and replacement of casing as required and reinstall the same inside the borewell after repair complete all including flushing of bore well complete all as directed and specified. Note; rate quoted by the contractor inclusive of all arrangement required to remove the submersible pump set stuck inside the borewell and reinstall the same after repair including removing and refixing of coloumn pipe , casing pipe, electrical connections ets as required . Repairing of submerceable motor and PVC casing pipe will be measured and paid separately under relivent items
M&L for heavy dyty PVC casing pipe of size 150 mm for bore well complete all specified and directed.
Notes for Sl no 1 to 4 : Note:- (a) All existing incoming and out going cables are to be connected to the above panel with proper lugs, glands nuts, bolts etc the cost of work is deemed to be included in the above item.. (b) The cost shall also be include the breaking of floors/walls IF ANY including digging of trenches for removing of cables of loops and connecting to the new panel boards and making good the disturbed surfaces to match with the existing surfaces (c) The panel shall be Fabricated from a reputed firm(CPRI Approved) . Make of MCCB's: L&T or equivalent in Havells, lEGRAND etc. (d) All Internal connection between MCCB and Changeover and Bus bar shall be connected by aluminium strip of suitable size and capacity. (e) All MCCB to be connected with both side Spreader Link .(f) Sufficient space to be provided for cable connection between MCCB and Bottom of the panel board. (g) Base of the panel should not be less than 600 cmm above the ground level. Necessar PCC for base /foundation required deemed to be included in the quoted rate. (j) The rate shall deemed to be include in the item rate. (k) All serviceable MCCB in existing panel board are the property of the department
Supply,lay, test and commissioning XLPE insulated and PVC sheathed heavy duty LT 1100 Volts grade armoured under ground cable with aluminium conductor of 2 Core 10 Sqmm in trenches/fixed to walls/poles etc connecting buy using lugs and commissioning ncl taking out of existing cable all as directed. Note :- Earth work excavation, sand cushioning and brick protection shall be measured and paid separately.
All as per item no:05 above but 4 Core 10 Sqmm
All as per item no:05 above but 4 Core 16 Sqmm
All as per item no:05 above but 3.5 Core 25 Sqmm
All as per item no:04 above but 3.5 Core 50 Sqmm
All as per item no:04 above but 3.5 Core 95 Sqmm
All as per item no:04 above but 3.5 Core 120 Sqmm
All as per item no:04 above but 3.5 Core 185 Sqmm
All as per item no:04 above but 3.5 Core 240 Sqmm
Taking out and Relaying of LT cable of size10sq mm to240Sqmm 2/3.5 core after carrying out necessary Repair such as joining with Epoxy joint and laid with sand Cushioning and brick protection and making connection By using Lugs all as specified and directed by ingr in charge. Note: ( Earth work , sand Cushioning, brick protection, Lt Joints shall be measured and paid separately under Relevent Item) (b) Retrived serviceable bricks/ PCC cover shall be reused under relevent item)
Supply and lay GI tubing , 100 mm bore light grade for cable protection at road crossing / on poles/ fixing of post top lantren and tubing sealed at both ends after laying the cables complete all as directed by Engineer-in-Charge. Make :- ISI
All as per item no:15 above but 80 mm bore
All as per item no:15 above but 50 mm bore
All as per item no:15 above but 40 mm bore
Supply and Fixing of cable jointing kit for 1.1 KV grade cable for outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 35 sqmm to 150 sqmm complete including taking out old unserviceable one all as specifide and directed.
Supply and Fixing of cable jointing kit for 1.1 KV grade cable for outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 sqmm to 300 sqmm complete including taking out old unserviceable one all as specifide and directed.
Cutting & trimming of tree branches any girth and size touching to overhead lines and cleaning the distance 1.5 mtr both sides of overhead line with in a gap of span 35 mtrs each depositing the same for cleaning the site all as directed by the Engr-in-Charge.
Excavation in trenches not exc 1.5 mtr wide and n.exc 1.5 mtr in deep and getting out in Hard/Dense soil laying of cables etc.
Returning filling in including spreading, leveling watering and well ramming in layers n.exc 25cm thick using excavated soil
Removing excavated surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5mtr above from the starting point
Supplying and laying un reinforced precast concrete cable cover class LV , Type 1 flat with size 250mm x150 mm x 40mm all as specified and directed by Engr-in-Charge.
M & L for brick protection cover of old size bricks common burnt clay building bricks sub class ’B’ of size 230 X 113 X 75mm laid dry and flat abutting each other with width equal to length of brick and gap between adjacent bricks not exceeding 10 mm complete all as specified.
M&L filling approved river sand in trenches for sand cushioning of laying of cables to the full width of excavated trench 8 cm thick before laying the cable and 15 cm above the cable, gently punned down etc complete all as specified and directed. Note :- Sand cushion after punning down thickness 18 cm shall be measured for payment purpose.
M & L cutting of road, hard standing made of concrete or premix carpet, WBM, soiling and morrum filling including excavation for laying of cable pipe all as directed and making good the road/hard standing by using all old/new materials and top 200 mm with PCC (1:2:4) etc, required to match with the existing surface complete all as specified and directed.
M&L for cleaning thoroughly the street light poles/LT distribution poles of any height and any description (Maximum 11 Mtr long ) with necessary cleaning agent including scrapping of old corroded paint dirt/ rust carefully and applying two coat of synthetic aluminium paint over existing coat of paint including marking of pole numbers and colour washing of pole coping complete all as specified and directed by Engineer-in-Charge. Make:- ASIAN (APCOLITE)/ SHALIMAR (SUPERLAC)/ BERGER (LUXOL)
All As per item No: 29 but for Two pole structure
All As per item No: 29 but for Four pole structure
S&F galvasised steel strip 32X6 mm with saddles and fixing screws on poreceling insulator/ spacer fixed at every 1 mtr length as lightening conductor on roof/wall of explosive building and joining the same with existing earth test point all as directed by Engr-in-Charge.
Advance Maintenance Free G.I. SAFE EARTHING Electrode with PIPE of not less than 50 mm outer dia( THICKNESS NOT LESS THAN -2.5MM) and two meter length, The electrode should be of galvinised (80 -100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm 7.5 m . The GI Electrode shall be pre-filled with Cristaline Conductive Material (CCM) . The GI electrode shall be surrounded with 25 kg BackFill compound to provide maximum contact between the electrode and Back Fill Compound. Backfill compound should be eco-frendly and having RoHs certification . GI Electrode Shall be tested from CPRI.The earting pit should be cover with pcc(1:2:4 , B1) cover ,of 300 x 300 mm complete all as specified and directed make ASHLOK / INDELEC/JMV /TERCEL.
M&L preparing Steel and Iron Surfaces of any description, over 100mm width or girth and applying One Coats of Synthetic Enamel Paint over a Coat of Red Oxide Zinc Chrome Primer, complete all as specified and as directed.
M&L for stright Through Joint heat shriankable type suitable for 1100 volt 185 to 300 Sqmm 3.5 core complete all as specified and directed
M&L for stright Through Joint heat shriankable type suitable for 1100 volt 70 to 150 Sqmm 3.5 core complete all as specified and directed
M&L for stright Through Joint heat shriankable type suitable for 1100 volt 25 - 50 Sqmm 3.5 core complete all as specified and directed
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, out door type,LT FEEDER PILLAR BOX made out of 3.15 mm thick CRCA Sheet of size 1MX.75mX.35M with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System ,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeded with 50X50X6mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level comp -lete with internal connection with suitable size of cable ,cable lugs,and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Test-ing after Installation complete all as specified and comprising of the following :– (a) Aluminium bas bar 200amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. b) MCCB 100 amps ,415 volt,16 KA Breaking capacity 4 pole Electromagnetic release duly connected to Bus Bar As INCOMING - 01 NosMake Legrand model no: 420015/ Equivalent from Schinder/L&T/Hagar
M&L for road crossing/drain crossing by adopting trench less tunneling work through specified pipe jacking method by erecting the equipment to true to the allignment and gradient by hydrolic pipe jacking technique complete including tunneling, excavation in any type of soils including hard rock, MS casing pipe havy duty of size 80 mm dia with 6 mm thick in any length including jointing materials to carry LT UG cables of size upto 150 Sqmm and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorites complete all as specified and as directed.
Supply and replace contactor ML 3 with coil operating voltage 230 Volt complete all as directed
Timer Analog Type Suitable for 24 hours operation of street light of 16 amps capacity (LEGRAND/AVV/CG)
Supply and fix MCB TPN 32 Amps 10 KA, C Curve complete all as directed
S&F new generation energy saving and environmental friendly long life varsatile pressure die cast aluminium IP66 road way light fitting with high power LED as light source of capacity 90 watts with suitable drivers etc and connecting with 4.0 Sqmm aluminium conductor PVC insulated twin core weather proof cable etc, fixing to wall/poll with and including bracket made out of GI pipe of suitable dia light grade not less than 1.5 mtr long, bent to shape, fixed to Pole/Wall in any position with flat iron clamps of size 30 x 4mm including taking down old unserviceable street light fitting of any type and capacity complete all as specified and directed. Make : Havells cat No : ENDURAPEARLPLUSSL90WLED757SASYTOPC or techno commercial equivalent model in Philips /Bajaj /Luker /Wipro/ Halonix.
Restreching/Restringing, tightening and repair to overhead line ACSR conductor of any size on LT poles including necessary Aluminium binding wire connectors PVC sleeves for jumper, fixing of insulators and prunning of tree complete all as specified and directed.
M&L for ACSR conductor, steel reinforced for LT over head lines on poles including streching tightining of poles insulator with binding wire of suitable size with insulator/streching of ACSR conductor including disconnecting/taking out old existing unsv ACSR conductors complete all as specified and directed.
Supply ,fixing, connecting and testing LED Post top lantern indirect type of 35 watt capacity with anti glare and uniform distribution including nut, bolts, washers, clamps etc complete all as specified and directed by Engr -in-charge Make : Havells Cat Pat No. RUBYPT35WLED830PSYMTOPC or equivalent in Philips, CG, Wipro, Halonix etc.
Supply, fixing, connecting and testing green line road way LED street lights of 60 watts capacity lighting with high power LED and unique peanut lens to ensure uniform distribution, complete all as specified and directed by the Engr-in-charge. Make : Crompton, Havell, Surya,Halonix or equivalent
Supply, fixing, connecting and testing LED Flood lights of 200 watts capacity lighting with high power LED and unique peanut lens to ensure uniform distribution, including nut, botls, washer, clamps etccomplete all as specified and directed by the Engr-in-charge. Make : Cromptron, Philips , Surya,Halonix or equivalent
Supply, fixing, connecting and testing LED Flood lights of 100 watts capacity lighting with high power LED and unique peanut lens to ensure uniform distribution, including nut, botls, washer, bracket &clamps (made out of MS angle of size 0.5 meter) etc complete all as specified and directed by the Engr-in-charge. Make : Cromptron, Philips , Surya,Halonix or equivalent
Fabrication and installation of GI pipe bracket made of midium Grade tubing of size 40 mm dia, duly bended by hot forgoing after filling of sand, length 1.20 mtr including providing two pair of MS flat strip clamps 40 mm x 4 mm with GI bolts nuts and washer complete all as specified and directed
Material and Labour for drawing two runs of PVC insulated unsheathed single core multi stranded copper conductor FRLS cable of size 2.50 sq mm with one run of PVC insulated unsheathed single core multi stranded copper conductor FRLS cable of size 1.50 sq mm including 20mm dia PVC conduit of dia 20 mm medium gradeexclusive of boxes but inclusive of all tees, bends, elbow, reducers etc and fixing accessories such as couples, lock nuts, saddles, pipe hooks, clamps etc complete all as specified
S & F hot press moulded SMC junction / terminal box of size with internal diamensions of 200 x 140 x 95 mm with hinged door, incl provision of 2 way connector 415 Volts made out of polycarbonate or bakelite and 1 No MCB of 6 Amps with DIN bar, drilling holes for cable connections, connecting incoming and or out going cables by providing suitable of size of cable lugs/glands, fixied on pole by means of clamps made out of MS flat iron of size 25 mm x 3 mm including dismantling of old unserviceable all as specified and as directed.Make: Hensel/Syntex/C&S/neptune
M&L for Supply, test, erection & commissioning of Steel tubalar swaged poles staying in a truely vertical position till the foundations are properly set with the help of crane complete with cast iron base plate, finial taper plug, bolts, nuts & screws including drilling of holes to poles for clamps & hooks for running of earth wire/Strip complete all as specified type 410 SP-31,09 mtrs LT poles and inluding and applying two coats of aluminum paint over a coat of red oxide primer and marking of zebra crossings up to a height of 1.0m above the coping with black and yellow strips of synthetic enamel paint including white wash to the coping and marking of pole numbers complete all as directed by Engr-in-Charge. Note:- (i) Crane charges for erection shall be deemed to be including in quoted rate. (ii) Earth work, PCC, coping shall be deemed to invluding in quoted rate. (iii) The rates include staying the poles in truely vertical position till the foundations are properly set. (iv)The rates include cast iron base plate, nuts, bolts, screws, painting of steel tubular poles, drilling of holes in steel tubular poles for fixing of clamps, hooks for continuous earth wire/strip. (v) The rate quoted shall be inclusive of pole painting.
Excavating in trenches, not exc. 1.50 Meter wide and exc. 1.50 Meter but not exc. 3.00 Meter in depth, for Foundation of Poles, etc. and getting out in Hard/dense Soil, complete all as specified and as directed.
Cement Concrete 1:3:6 Type C2 (20mm Graded Stone Aggregate) as Lean Concrete in Foundation of Poles, Stay Assembly, etc., including Formwork AND FOR FOUNDATION OF GI PIPE , BOLLARD LIGHT (as/if required), complete all as specified and as directed.
Cement Concrete 1:3:6 Type C1 (20mm Graded Stone Aggregate) as in Coping of Poles, etc. including Formwork (as/if required), complete all as specified and as directed.
Supply and fixing bracket/clamps made of MS flat strips, angle iron suitable size and shape duly fabricated and painted to be fixed with GI bolts/nuts and washer for fixing of GI bracket, PVC conduit, pole junction box or flood lights all as directed and specified
Supply and replace GI pipe fixed on the top of gate piller by 50 mm dia medium grade GI pipe of length 30 cm( 20 CM inside the piller and 10cm above the piller ncluding necessary cement work and making hole on GI pipe if required complete all as directed. Note: Quoted rate inclusive of making good of dosturbed suface including necessary painting to match with the adjoining surface.
M&L for twin core 1100 volt grade aluminium service wire cross sectional area 4.0 Sqmm for connection of light complete all as specified and directed
Cutting anxious green growth / vegitation growth for cleaning out the area around transformer installations and four pole structure yards at ground level by cutting out roots, un wanted plants bushes and removel of the same by surface excavation not exceeding 30 cm deep average 15 cm complete
M&L for stay assembly with all accessories as shown in Electrical Plate No 1 of SSR Part I (2009) with 16 mm dia stay rod and including 7/2.24 mm size stay strand and stay clamps including dismantling old unserviceable stay assembly complete all as specified and directed. Note : Loop type insulator, excavation, earth work and concrete shall be measured and paid separately under relevant items of this schedule.
Cross-arms, Bracings, Supports, Clamps and Back Plates fabricated from Structural Steel Sections including Nuts, Bolts, Washer, welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated or directed and inclusive of One Coat of Aluminium Primer, One Under Coat and One Finishing Coat of Aluminium Paint, complete all as specified and as directed.
S&F galvasised steel strip 32X6 mm with saddles and fixing screws on poreceling insulator/ spacer fixed at every 1 mtr length as lightening conductor on roof/wall of explosive building and joining the same with existing earth test point all as directed by Engr-in-Charge.
Supply and fix stay wire galvnised stay strand of size 7/3.15mm
Srinivasa Consructions
STANDARD AGENCIES
omsai thermax engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .