Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.3 LAccepted-AOC NEAR PARDEEP MEDICAL HALL DEEP NAGAR JALANDHAR CANTT JALANDHAR PUNJAB 144005 | JALANDHAR | PUNJAB | 144005 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹34.3 L+₹1.5 L (4.62%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest Bidder | |
| 3 | L3₹36.3 L+₹3.6 L (11.0%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest Bidder | |
| 4 | L4₹36.9 L+₹4.1 L (12.6%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest Bidder | |
| 5 | L5₹37.3 L+₹4.6 L (14.0%)Rejected-Finance NO 354 2ND CROSS VARADARAJNAGAR VIDYARANYAPURA POST BANGALORE 5600 097 | 5600097 | L5 | Rejected-Finance Other than Lowest Bidder |
Tender Value
₹42.6 L
EMD Value
₹85,200
Closing Date
4 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Kapurthala
GE Kapurthala
Augmentation of electric supply network at Mil Stn Beas and Provn of security lights Near the perimeter wall from Small Arms Firing Range at New Mil Stn Kapurthala under GE Kapurthala
2022_MES_569070_1
GE KPT- /2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Kapurthala
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE Kapurthala
₹85,200
Yes
11 Apr 2023
14 Dec 2022
6 Jan 2023
14 Dec 2022
4 Jan 2023
28 Dec 2022
Amount
Excavation in trenches in hard/dense soil not exceeding 1.5m wide and not exceeding 1.5 metre in depth for laying of cable and not exceeding 10 Sqm on plan for poles, struts, stays etc. and not exceeding 1.5 m in depth and getting out complete all as specified.
All as per item No. 1 above but depth exceeding 1.5 metre & not exceeding 3.00 metre.
Returning, filling in, trenches including spreading leveling, watering and well ramming in layers not exc 25 cm.
Removing excavated material to a distance not exc 50 mtrs and depositing where directed at a level n.exc 1.5 mtr above the starting point.
Supplying, filling in trenches, spreading, leveling sand cushioning 8 cm below cable and 15 cm above the cable punned down to 10 cm for under ground cable complete all as specified & directed . Note : Punned down sand will be considered for measurement
M&L for Protection to cable with one layer of new bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class ‘B’ bricks.
Dismantling of existing old ACSR conductors, any size, from existing LT poles at area where UG cables are to be laid, by unwinding the binding wire from insulators including disconnecting from the existing system, keep in safe custody for reuse, all as directed. Note : (a) Payment for taking down of insulators shall be made for separately.
Dismantling of existing old cross arms etc made of mild steel channel, angle iron, flat iron, back plates, nuts, bolts, washers etc all as directed.
Dismantling/taking down of insulators of any type/size from LT poles complete all as directed.
Supply and laying in trenches/through pipes or bare in road crossings/paths/drains/ducts/floors/along poles/walls/ ceilings/ equipments etc. Cable Under ground, Heavy duty, armoured, XLPE insulated with stranded aluminium conductor, 1100 Volts grade of following cross sectional area all as specified and directed by the Engr-in-Charge :-
(a) 300 Sqmm 3.5 core
(b) 185 Sqmm 3.5 core
(c) 120 Sqmm 3.5 core
(d) 95 Sqmm 3.5 core
(e) 70 Sqmm 3.5 core
(f) 50 Sqmm 3.5 core
(g ) 35 Sqmm 3.5 core
(h) 25 Sqmm 4 core
(j) 16 Sqmm 4 core
(k) 16 Sqmm 2 core
M&L for making joint using out door cable straight through jointing kit (Epoxy/Heat Shrinkable type) suitable for PVC/XLPE under ground aluminium conductor cable, 1100 Volts grade including crimping aluminium socketes of suitable size complete of following cross ectional area :-
(a) 16 to 35 Sqmm 3.5/4 core
(b) 95 to 120 Sqmm 3.5 core
M& L for cutting the existing hard standing/PCC/WBM road at a depth not less than 30 cm and 25 cm in width for passing of cable through GI pipe, returning filling in, complete including finishing the surfaces by providing cement concrete type B-1 (1:2:4) with 20 mm graded aggregate upto 20 cm, finishing to a uniform smooth surface complete all as specified and directed.
Supply and lay in trenches/under roads/crossings are fixed to wall/pole, GI tubing light grade of following sizes for protection of UG cables :- Note : Payment for excavation and earth work shall be paid for separately under relevant items of Schedule.
(a) 80 mm dia
(b) 50 mm dia
Supply and fix PVC moulded junction box of Sintex or equivalent PVC looping box comprising of 04 Nos Aluminimum bus bar mounted on insulator and one No 6 Amps SP MCB and connecting terminals 4 way including necessary Clamps made out of MS flat iron, nuts and bolts suitable for fixing on PCC /Steel tubular Poles complete all as directed.
M & L for wiring for Circuit from MCB box to Street light including supply and fixing (with suitable clamp) of pvc conduit of size 20 mm dia on pole with FR PVC insulated copper conductor single core cable with 2 x 1.5 sqmm + 1 x 1 Sqmm earth wire in surfaces/recessed as required and as directed.
Supply and install hot dip galvanized steel Octagonal pole 9.0 mtr long, top dia 70 mm & bottom dia 130 mm having thickness 3 mm having door operating of size 500 mm above ground level with CI Base plate of size 200x200x16mm having PCD 200 mm, foundation bolts of size 20 mm dia(04 Nos)600 mm long and having hot dip galvanized double plain arm bracket 1000 mm long overhang on both side with 48.3 mm outer dia pipe of thickness 3.2 mm fixed on top with bolts complete all as specified. & directred. Make : BAJAJ/CROMPTON/HAVELLS Note: PCC and earth work shall be measured and paid seperately
Supply and fixing LED street light fitting 90 Watt 230 V AC Raptor NEO street lights are aerodynamically designed for weather conditions with excellent thermal management made with high pressure die cast housing with toughened glass and high power LEDs with secondery optical and IP 65 protection efficiency > 110LPW 10KV SPD included ,complete all as specified.Make-Crompton Cat part No TRP-409-70-57-SL-GL-NSG or equivalent in Havells/Bajaj/Philips.
Material and labour for PCC 1:4:8 type D2 (using 40 mm graded stone aggregates) as in foundation bed and around the pole as mass concrete including necessary form work and finishing the exposed surface even and smooth without using extra cement complete all as specified and directed.
All as per description of seiral item No 18 here-in-before but PCC (1:2:4) type B-1 using 20 mm graded stone aggregates as in coping of poles.
Supply Install , testing and commissioning LT Distribution Panel (CPRI Approved) cubicle type IP-56 , Outdoor type conforming to IS 61439, factory fabricated made out of 3mm thick CRCA sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories / fittings compartmentalized in construction to accommodate the incoming MCCB and TPN bus bars and outgoing feeders . The TPN bus bars shall be insulated with colour coated heat shringable sleeve and shall be mounted on DMC/ epoxy insulator . The incoming as well as outgoing MCCBs shall have extersion links of current carrying cap not less thatn 1.5 times the rated capacity of induvidual feeders. The extension links shall be supported on DMC/ Epoxy insulators having provision for termination of incoming and outgoing cables. All extension links/ interconnections hsall colour coated sleeves. The cubicle shall have frame work, bottom & 45 CM long 4 legs of size 50 x50 x 6mm angle iron , grouted in PCC 1:3:6 as directed by Engr-in-Charge . A detacheable gland plate of thickness not less than 3 mm thick should be used at the botom for entry of armoured cable of adequate size compression glands, the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seven tank phosphating treatment , front & back opening type, and fixing 2 Nos danger notice plate with leter , figures and conventional skull bones in signal red colour anf dixed front & back dor to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have lourvers and airvent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following .
(a) Busbar TPN , Aluminum 400 Amps -01 Set ( In Coming)
(b) MCCB 4 Pole, 415 V, Adjustable type,250 Amps with breaking capacity 36 KA- 01 No ( In Coming)
(c) MCCB 4 Pole, 415 V, Adjustable type, 100 Amps with breaking capacity 36 KA- 07 No (out Going)
(d) MCB TPN , 415 V, 63 Amps ,10 KA- 03Nos (out Going)
(e) MCB 2 Pole, 240 V, 63 Amps ,10 KA-03 Nos (out Going)
(f)Digtal Voltmeter 0-500volts
(g) Digital Ammetor 0-400amps with CTs
(h) Indicator lamps
Note:- LT Panel board should be as per IS/ IEC 61439 Part-I & II Type test certificates for 4000 Amps with Breaking capacity not less than 65KA. Panel builder should submit all certificate before the Drawings approval. (ii) Platform for the feeder pillar board with PCC 1:2:4 15 Cm thick in foundation, Brick (Sub Class B) work in CM 1:6 ,rendering 1:6 on exposed surfaces and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting legs of panel . The platform shall be of 600 mm height above ground level and minimum 400 mm below the ground level. Note Rate for the same included in the quoted rate.
Supply Install , testing and commissioning LT Distribution Panel (CPRI Approved) cubicle type IP-56 , Outdoor type conforming to IS 61439, factory fabricated made out of 3mm thick CRCA sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories / fittings compartmentalized in construction to accommodate the incoming MCCB and TPN bus bars and outgoing feeders . The TPN bus bars shall be insulated with colour coated heat shringable sleeve and shall be mounted on DMC/ epoxy insulator . The incoming as well as outgoing MCCBs shall have extersion links of current carrying cap not less thatn 1.5 times the rated capacity of induvidual feeders. The extension links shall be supported on DMC/ Epoxy insulators having provision for termination of incoming and outgoing cables. All extension links/ interconnections hsall colour coated sleeves. The cubicle shall have frame work, bottom & 45 CM long 4 legs of size 50 x50 x 6mm angle iron , grouted in PCC 1:3:6 as directed by Engr-in-Charge . A detacheable gland plate of thickness not less than 3 mm thick should be used at the botom for entry of armoured cable of adequate size compression glands, the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seven tank phosphating treatment , front & back opening type, and fixing 2 Nos danger notice plate with leter , figures and conventional skull bones in signal red colour anf dixed front & back dor to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have lourvers and airvent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following .
(a) Busbar TPN , Aluminum 250 Amps -01 Set ( In Coming)
(b) MCCB, 415 Volt, 4 pole, of capacity 160 Amps - 1 No ( In Coming)
(c) MCCB, 415 Volt, 4 pole, of capacity 63 Amps, 16 KA - 3 No
(d) MCB, SPN, 63 Amps, 10 KA - 3 Nos
(e) Digtal Voltmeter 0-500volts
(f) Digital Ammetor 0-400amps with CTs
(g) Indicator lamps
Note:- LT Panel board should be as per IS/ IEC 61439 Part-I & II Type test certificates for 4000 Amps with Breaking capacity not less than 65KA. Panel builder should submit all certificate before the Drawings approval. (ii) Platform for the feeder pillar board with PCC 1:2:4 15 Cm thick in foundation, Brick (Sub Class B) work in CM 1:6 ,rendering 1:6 on exposed surfaces and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting legs of panel . The platform shall be of 600 mm height above ground level and minimum 400 mm below the ground level. Note Rate for the same included in the quoted rate.
M & L in replacement earthing complete with GI or steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically in a pit not less than 2.25 meter below ground level with top edge of earth plate at a depth not less than 1.5 meter below level covered on all sides with alternative layers of charcol dust and common salt 15 cm thick connected to galvanised earth lead Galvanised Iron strip 32 x 6 cm by means of bolts, nuts, check nuts and washers of Galvanised Iron or steel with protection pipe earth wire protected by galvanized steel pipe light grade 40 mm bore from top of the earth plate electrode upto test point and watering pipe 20mm bore, GI light grade with funnel and wire mesh all as shawn in electrical plate No 3 of SSR Part-1 and connected to earthing test point all as specified or indiated and testing on completion, including PCC earth pit (1:3:6) type C-2 RCC covered with CI cover hinged with frame including excavation and earth work complete all as specified.
M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed.
Supply and fix in replacement of Time light distribution board analog Time switch 230 volt three phase of 40 Amps rating with contactor fixed inside steel enclosure box and fixed to pole/LT Panel including clamps, nuts, bolts and washers etc complete all as specified and directed.Make Indo-Asian cat part No TL016ABO or equivalent in Legrand/Scheneider
M/s Shri Krishna Enterprises
B.L. Chaudhri and Co.
M/s Surjit Singh and bros
S S BUILDERS
shivam builders
M/s Bansi Lal
SATIJA BUILDERS
Karan Engineers
SHSS ASSOCIATES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .