Executive Engineer Pundri W/S Division Kaithal
Construction of permanent pump house at Habri Sub Branch at RD. 69500-L and 69500-R in village Sanch
2022_HRY_224982_1
5073-96 /14-A dated 08.06.2022
Open Tender
Civil Works
Item-rate/Agreement basic
120 days
Kaithal
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,500
₹64,900
Yes
14 Sept 2022
10 Jun 2022
17 Jun 2022
10 Jun 2022
17 Jun 2022
10 Jun 2022
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means infoundation trenches or drains (not exceeding 1.5 min width or 10 sqm on plan), including dressing of side sand ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of lus excavated soil as directed, within a lead of 50 m. (HSR 4.14)
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. All kinds of soil (HSR 4.12.1).
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1:2:4 (1 cement : 2 coarse sand (zone-Ill) : 4 graded stone aggregate 20 mm nominal size) (HSR No. 6.1.2.)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1:3:6 (1 Cement : 3 coarse sand (zone-Ill) : 6 graded stone aggregate 20 mm nominal size) (HSR No. 6.1.4)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to 1 : 1 ½: 3 ( 1 Cement: 1 ½ coarse sand (zone-Ill) : 3 graded stone aggregate 20 mm nominal size) (HSR No. 6.1.1)
Brick work with common burnt clay non modular bricks of class designation 10 in foundation and plinth in: Cement mortar 1:4 (1 cement: 4 coarse sand), Cement mortar 1 :4 (1 cement : 4 coarse sand).cement mortar 1 :4 (1 cement : 4 coarse sand) (HSR 7.21.1)
Brick work with common burnt clay non-modular bricks of class designation 10 in superstructure above plinth level up to floor IV level in all shapes and sizes in : mortar 1:4 (1 cement : 4 coarse sand) : (HSR 7.22.1)
10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1: 1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1 :3 (1 cement: 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: With common burnt clay non-modular brick tile of class designation 10. (HSR 9.11.1)
Providing and laying of Conglomerate floor 25 mm thick cement concrete 1:2:4 on 100 mm cement concrete 1:8:16 and 100 mm sand or stone filling. (HSR 10.9)
Supply & fixing Windows frames (Chowkhats) including mullions consisting frame fabricated from sheet roll formed out of 1.2mm thick galvanized sheet as per IS:277 (Base steel as per IS 513) with zinc of 120 gm/sqm & Powder coated with pure Polyester powder up to 50 microns (as per approved colour), 3 Nos. 100mm butt - hinges 2mm thick, 6 Nos. 1.2mm thick CRCA electroplated stiffner, 6 Nos. M.S hold fast with split and tail welded to stiffner plate 200mm long, receiver for aldrop, weld less corner assembly with brackets & screws, M.S tie rod 50mm x 25mm to be fixed at bottom finished with powder coated total thickness of coating 0.6mm of approved shade, fixed in position including the cost of cement concrete for 1:2:4 for fixing lugs complete in all respects as per drawing, design, specification & entire satisfaction of Engineer-in-charge. Door Frame of size wide double rebate for 35mm door shutter .(HSR13.21.1)
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, including ISi marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately} Kiln seasoned and chemically treated Hollock wood : 35 mm thick shutter (HSR 12.7.2.1)
Providing and laying damp-proof course with cement concrete 1 :2:4 (1 cement : 2 coarse sand (zone-Ill): 4 graded stone aggregate 12.5mm nominal size) 40mm thick (HSR 6.8.2)
12 mm cement plaster of mix, 1 :3 (1 cement: 3 fine sand) (HSR 11.5.2)
Pointing on brick work or brick flooring with cement mortar 1 :3 (1 cement : 3 fine sand): Raised and cut pointing (HSR 11.25.2)
PVC insulated copper conductor wiring 1.6mm thick conduct pipe. Wiring for Light/Fan/call bell point with modular type switch/socket and box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated conductor cable in 1.6 mm thick PVC conduit pipe (4 No. Fan Point & 16 No. Light Point) (HSR 23.4.1.2 Group B)
PVC insulated copper conductor wiring 1.6mm thick conduct pipe. Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required (HSR 23.4.4.2 Group B)
PVC insulated copper conductor wiring 1.6mm thick conduct pipe. Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required (HSR 23.4.5.2 Group B)
Distempering with dry distemper of approved brand and manufacture (one or more coats) and of required shade on old work to give an even shade. (HSR 30.24)
Structural steel such as tees, angles channels and R.S. joists. Hoisting R.S.Joists and placing in position up to floor IV level (HSR B0942 & HSR No. 9.8)
Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc. (HSR 11.77)
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (HSR 11.78)
Planking of commercial hard wood, such as Hollock, champ, chikrassy and chaplash etc., (Non-coniferous timber other than teak conforming to I.S. specification no.1003 kiln-seasoned) planed on both sides, rebated and fixed in position, including nails and screws, etc: 50 mm thick (HSR 12.24.1)
Finishing walls with water proofing cement paint of required shade. New work (Two or more coats applied (HSR11.93)
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , xcluding overlaps. Wastage, overlaps, couplings, welded joints,acer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. Thermo-Mechanically Treated bars of grade Fe-500D or more. (HSR 6.33.6)
Providing lowering cutting jointing and testing RCC pipe class NP 3 as per 18-458-2003 with spigot & socketed joints manufactured with ISi marked sulphate resistance cement as per ISi 12330 with rubber rings ISi marked antiternmite as required at site in to trenches for all depths and laying out the same to correct alignment gradients and levels including dressing and trimming and cutting of concrete beds and side of trenches, if required jointing with rubber rings in trenches and jointing with 1 :3/2 cement sand mortar and with end dowels filled with 1 :3/2. cement sand mortar and finishing the joints at an angle of 45 degree with faces of spigot of socket joints cutting and finishing the cut surface to a uniform finish etc. as fully described in item No . 21.38, item 21.44, item 21.45, & item 21.46 including cartage loading and unloading complete in all respects. the internal diametric of the sewer being: (600 mm dia) HSR (21.95.5)
Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 1 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.. HSR (4.33)
Providing and laying dry brick on edge flooring in equired pattern with bricks 104 426 531of class designation 10 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. HSR (10.34)
Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes : 110 mm diameter (HSR 9.57.2)
Supply and erection of suitable compression type brass cable glands for underground Cable. 1O sqmm to 16s qmm Cable 2 to 4 Core. HSR (24.2.7.2)
Providing and fixing aluminium sliding door bolts, ISi marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete HSR (12.98)
Centering and shuttering including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. (HSR 6.30.2)
Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases for columns (HSR 6.29.1)
Center and shuttering including strutting, propping etc and removal of form for roofs/slab (any thickness) including attached plasteres butteresses, plinth and string corses etc. HSR No. (6.30.3)
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilever. (HSR 6.30.5)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .