| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.7 LAccepted-AOC 1 6 620 CHAITANYAPURI INDRA NAGAR DILSUKHNAGAR HYDERABAD TELANGANA 500060 UDYAM TS 09 0007870 37AAEPO0535A1Z8 B 36AAEPO0535A1ZA R MSME STATUS AS VERIFIED | RANGA REDDY | TELANGANA | 500060 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹48.5 L+₹4.1 L (9.25%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹49.1 L+₹4.8 L (10.8%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹49.4 L+₹5.0 L (11.3%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹49.5 L+₹5.2 L (11.6%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
3 Jul 2021, 6:00 pmClosed
Garrison Engineer M NAS Arakkonam
Garrison Engineer M NAS Arakkonam 631006
REPAIRS TO HARDSTANDING AND WALKING PATHWAYS AND MAINTENANCE WORK TO STREET LIGHTS AND SOLAR LIGHTS AT VARIOUS LOCATIONS AT ARAKKONAM
2021_MES_449389_1
8995E8
Open Tender
Civil Works
Item Rate
150 days
Arakkonam
As per NIT
7 documents required · 7 mandatory
₹500
Garrison Engineer M NAS Arakkonam
₹90,000
Yes
16 Jul 2021
8 Jun 2021
6 Jul 2021
8 Jun 2021
3 Jul 2021
21 Jun 2021
8 Jun 2021 - 14 Jun 2021
Amount
Taking down cement plaster or concrete etc., (external / internal wall surface etc) including racking out joints hacking for key scrubbing down with water etc., complete all as specified and as directed. Note : 1. The work shall be carried out upto six storey (G+5) buildings. 2. The rate quoted inclusive of necessary scafolding etc
Material and labour for 15mm thick rendering into two layers consisting 10mm thick in CM 1:4 followed by 5mm thick in CM 1:4 with WPC on fair faces of brick work or concrete surface including finished even and fair without using extra cement complete all as specified and as directed. Note: WPC shall be measured and paid separately.
Supply only integral water proofing compound.
Material and labour for preparation of new plastered surfaces of walls and applying two coats of cement based paint white or tinted over a coat primer complete all as specified and as directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for and removal and rubish off premises exc 500m but not exc 1.5 km complete all as specified and as directed. Note : 1. The work shall be carried out in shaft area of height upto six storey (G+5) buildings. 2. The rate quoted inclusive of necessary scafolding etc
Material and labour for providing precast cement concrete louvers and jallies, 25mm thick (measured solid) including all mouldings set in cement mortar 1:6 type B0 1:2:4 (Using 12.5 mm graded stone aggregate) complete all as specified and as directed. Note : 1. The work shall be carried out in shaft area of height upto six storey (G+5) buildings. 2. The rate quoted inclusive of necessary scafolding etc
Demolition of cement concrete ( unreinforced) in ground floors and paving n. exc 15 cm thick ( below & above ground level) and removal & rubish of Premises exc 250 m but n exc 500 m complete all as specified
Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc, laid dry
Material and labour for plain cement concrete type D-2, 1:4:8 (Using 40mm graded stone aggregates) as in sub base complete all as specified and as directed.
Material and labour for M- sand filling as a cushioning/ bedding complete all as specified and as directed.
Material and labour for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and no pigment complete all as specified and as directed.
All as per ser item No 11 above but except paver blocks complete all as specified and as directed.
Material and labour for chequred cement concrete tiles 300x300x20-22mm thick set, jointed and pointed in neat cement slurry over and including 20mm thick screed bed in CM 1:6 with coloured cement to match the shade of tiles complete all as specified and as directed.
Material and labour for cement concrete type B-0, 1:2:4 (Using 12.5 mm graded stone aggregates) for edging/coping complete all as specified and as directed.
Demolition of brickwork or stone/ boulder masonry, build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework complete all as specified and as directed.
Material and labour for walling random rubble, brought upto courses well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and as directed.
All as per item No.16 here-in-before but except stone.
Material and labour for plain cement concrete bond stones type B1, 1:2:4 (using 20 mm graded stone aggregate) complete all as specified and as directed.
Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints, with maximum depression on face from straight edge held against the dressed surface n exc 40 mm, as specified, of random rubble walling, uncoursed or brought upto courses; complete all as specified and as directed.
Material and labour for racking out joints/ pointing to random rubble or polygonal rubble uncoursed or brought up to courses built in cement mortar complete all as specified and as directed( Applicable for old work if any ).
Material and labour for flush pointing to random rubble mansonry, uncoursed or brought upto courses in CM 1:3 complete all as specified and as directed.
Material and labour for brick work with sub class 'B' bricks straight or curved on plan exc 6m mean redius built in CM 1:4 complete all as specified and as directed.
Material and labour for brick work with sub class 'B' bricks straight or curved on plan to any radius as in half brick thick walls built in CM 1:4 complete all as specified and as directed.
Material and labour for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 and finished even and smooth without using extra cement complete all as specified and as directed.
Material and labour for three coat white wash on newly plastered surfaces of wall including preparation of surface complete all as specified and as directed.
Supply and fix 75mm dia bore PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed.
Material and labour for hardcore of gauge not exc 63mm, deposited, spread and levelled in layers not exc 15cm thick, watered and rammed to a true surface complete all as specified and as directed.
Material and labour for 75mm thick PCC 1:3:6 type C-1 (Using 20mm graded stone aggregate) as in plinth protection, including finished even and smooth without using extra cement complete all as specified and as directed.
Material and labour for preparation of old decorated surfaces of walls by by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent walls and trading oil and greasy spots and applying one coat of cement based paint white or tinted complete all as specified and as directed.
Demolition of cement concrete (reinforced) in ground floors and pavings n.exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
Material and labour for precast reinforced cement concrete 1:2:4 type B1 (Using 20mm graded stone aggregate) as in cover slab for drain set in CM 1:6 complete all as specified and as directed.
Supply and fix for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Taking down unserviceable LED light fittings of any watt and type from existing position on pole/ wall/ tower/gate, complete for and including repair and refixing in existing position after repair all as specified and as directed Note: (i) New spare parts required for replacing old unserviceable parts shall be measured and paid separately as ‘ Supply only’ under relavent item here-in-after ii) Labour cost for replacing spare parts,removing unserviceable parts, dismantling light fitting and refixing are deemed to be included in the quoted rate.
Supply only outdoor drivers any type and of following wattage for flood lights/post top latern lights/street light/security lights including necessary connecting arrangements as per site requirement all as specified and directed. Make : Philips/Wipro/Surya/Crompton
Out door type drivers suitable for 25 watts LED lights
Out door type drivers suitable for 40 watts LED lights
Out door type drivers suitable for 45 watts LED lights.
Out door type drivers suitable for 75 watts LED lights
Out door type drivers suitable for 150 watts LED lights
Supply only surge protection devicess any type and KV for following capacity flood lights/post top latern lights/street light/security lights including necessary connecting arrangements as per site requirement all as specified and directed. Make : Philips/Wipro/Surya/Crompton
Surge protection devices not less than 5 KV suitable for LED light fittings up to 75 watts.
Surge protection devices not less than 5 KV suitable for LED light fittings 75 watts to 150 watts.
Taking down old unservicaeble security light junction box/bus bar box etc from existing security light poles / wall from existing positions including disconnecting existing cable connections carefully and MS clamps etc complete all as specified and directed.
Supply, Fixing and Testing Powder coated Outdoor street light control box of size not less than 300 x 200 x 80 mm CRCA 3 mm thick IP 65 fabricated by CPRI certified panel manufacturer including suitable terminal TPN 10 KA SMC Connector ( for 3 Phase Cable Line IN & OUT) and provision of dimrail for mounting 3 Nos MCB SP including S&F 01 No MCB 6 A SP C curve ( Make - Siemens / L & T / Schneider/Legrand/ABB), canopy weather proof, hinged door with Two hinges, pad side locking system - 02 Nos (top and bottom), for fixing on PCC / Steel Poles in and including necessary MS Clamps - 02 Nos of suitable shape and size with nut, bolts and washers as per site requirement complete all as specified and directed. Note - i) Drawing shall be approved by Deptt before placing a order to CPRI certified panel manufacturers. ii) The cost deemed to be included in the quoted rate for reconnecting Old existing cables to boxes carefully using a suitable glands and also taking up loop from the under ground and making good in all respect where ever required as per site requirement complete all as specified and directed.
Supply and fix MCB TPN 415 V, 40- 63 Amps 'C' curve Including taking down old unserviceable one all as specified and as directed. Make : Legrand/ L&T/ Siemens/Schneider/ABB
Supply and fix MCB SP 230 V, 6-32 Amps C curve Including taking down old unserviceable one all as specified and as directed. Make : Legrand/ L&T/ Siemens/Schneider/ABB
Supply and fix MCB SP 230 V, 40-63 Amps C curve Including taking down old unserviceable one all as specified and as directed.Make : Legrand/ L&T/ Siemens/Schneider/ABB
Supply,Fix and Testing LED street light luminaire fitting of not less than 45 Watt of not less than IP - 65 protection comprises of Pressure die cast Aluminium housing powder coated,with luminaire efficacy not less than 100 lm/w provided with Surge Suppressor 5 KV complete including taking down the old unserviceable/damaged light fittings and making good disturbed surfaces all as specified and directed. Make : Crompton Cat- LSTS-45-CDL-M / Surya Cat-SLE UL 45W IP66 LXN / Philips/Wipro/ Luker Note: (i) Quoted rate is deemed to be included the charges of necessary Ladder, tools and plants , necessary drilling,bolts / screws for fixing new one etc as per site requirement.and MS frame work if any complete as per site requirement. (ii) Quoted rate is deemed to be included the charges involved for the Contractor in submitting warrenty certificate for 5 years for the luminaries from manufacturer.
Supply,Fix and Testing LED flood light fitting of not less than 100 Watt, Luminaire fitting of not less than IP - 65 protection comprises of Pressure die cast Aluminium housing powder coated, toughened glass,luminaire efficacy not less than 100 lm/w provided with Surge Suppressor 10 KV including taking down the old unserviceable/damaged light fittings and making good disturbed surfaces all as specified and directed Make : Crompton Cat- (LFLN-120-CDL/60-M) / Surya Cat ref-SLE FL 100W IP66 LUMOS/ Philips/Wipro/ Luker Note: (i) Quoted rate is deemed to be included the charges of necessary Ladder, tools and plants , necessary drilling,bolts/screws for fixing new one etc as per site requirement.and MS frame work if any complete as per site requirement. (ii) Quoted rate is deemed to be included the charges involved for the Contractor in submitting warrenty certificate for 5 years for the luminaries from manufacturer.
Supply,Fixing and Testing LED flood light fitting of not less than 150 Watt, Luminaire fitting of not less than IP - 65 protection comprises of Pressure die cast Aluminium housing powder coated, toughened glass, ,luminaire efficacy not less than 110 lm/w provided with Surge Suppressor 10 KV including taking down the old unserviceable/damaged light fittings and making good disturbed surfaces all as specified and directed. Make : Crompton Cat- (LFLN-150-CDL/60-M) / Surya Cat-SLE FL 150W IP66 LUMOS / Philips/Wipro/ Luker Note: (i) Quoted rate is deemed to be included the charges of necessary Ladder, tools and plants , necessary drilling,bolts/screws for fixing new one etc as per site requirement.and MS frame work if any complete as per site requirement. (ii) Quoted rate is deemed to be included the charges involved for the Contractor in submitting warrenty certificate for 5 years for the luminaries from manufacturer.
Taking down old unservicaeble cable any make /type/size and supply and draw the PVC insulated round copper flexible cable multistranded of 3 core 1.5 sqmm with necessary arrangments all as directed by Engineer-in-charge. Make : Plaza/Finolex/Gloster/Nicco/Polycab/KEI.
Supply and fixing GI bracket for street light made out of 40mm dia GI pipe medium grade 1.5 mtr length bend in shape as required complete with MS flat iron clamp,nuts and bolts etc all as directed and specified including dismantling old damaged one all as specified and as directed
Surface excavation not exceeding 30 cm deep and average 15 cm deep and getting out in soft / loose soil including removing green vegetation,roots,bushes etc from surroundings near electric poles/panels or sub stations area Complete all as specified and directed.
Cutting and Trimming of tree branches touching street / security poles or light fittings etc, to clear the tree branches around the pole and maintain a clearance of 1.50 M radius of the pole top or light fitting complete all as specified and as directed. Note: (i) An area of 1.5 M surrounding the pole to be cleared off trees branches. (ii) Measurement and payment will be made for all cutting / trimming near top of the each pole as one job only.
Supply and lay pipe galvanised iron tubing light grade of 40 mm dia in trenches/under road or floor/on wall / near pole/panel etc all as per site requirement complete all as specified and directed.
Supply,laying for 16 sqmm 4 core XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor for replacement of un serviceable portion of cable,connecting with proper size Aluminium lugs, glands whereever necessary near LT Panels / Bus bar chamber panel/joints/poles including taking down the old unsevicaeble cable all as per site requirement , testing complete all as specified and directed. Make -: UNIVERSAL / POLYCAB / NICCO / PLAZA / INCAB / KEI.
M & L for black stove enamelled rigid ERW steel conduit 20 mm dia fixing with suitable size MS clamp / saddles as per site requirement complete all as specified and directed. Make :- BEC/EMCO/ GARWARE /JINDAL/ WAVIN/FINOLEX. Note - (i) Quoted rate for conduit is deemed to be included for the taking down existing unserviceable conduit as per site requirement complete (ii) New wiring portions for replacement of unserviceable wiring as required as per site requirement shall be measured and paid separately under relevant schedule item.
Material and labour for PCC 1:3:6 type C1 using 20 mm grade stone aggregate as in copping of electric pole at site including providing necessary form work etc including demolition complete all as specified and as directed.
Material and labour for cross arms, bracings, supports clamps and back plates fabricated from structural steel sections incl. nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coat of aluminium paint over a coat of red oxide primer including preparing the surface and old corroded item all as specified and as directed.
Material and labour for sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 1.5 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 1.5 sqmm as in continuous earth wiredrawn in existing conduit complete all as specified and as directed. Make:- Polycab / Havells / Gloster / Nicco
Supply,Fix and Testing LED street light luminaire fitting of not less than 60 Watt, Luminaire fitting of not less than IP - 65 protection comprises of Pressure die cast Aluminium housing powder coated,with luminaire efficacy not less than 100 lm/w provided with Surge Suppressor 5 KV complete including taking down the old unserviceable/damaged light fittings and making good disturbed surfaces all as specified and directed. Make : Crompton Cat- LST-60-CDL / Surya Cat-SLE UL 60W IP66 LXN / Philips/Wipro/LUKER
Excavation in trenches, n. exc 1.5 m wide and n. exc 1.5 m in depth for taking up / laying cable etc and getting out for soft/loose soil complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm for soft/loose soil complete all as directed.
Removing excavated material to a distance n.exc 50m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as directed.
Supply and lay standard size common burnt clay building bricks sub class 'B' for cable protection, laid dry complete all as specified and directed.
Relaying of reusable bricks as obtained from item ser No 55 here-in-before complete all as specified and directed.
Spreading riddled earth as obtained from item No. 55 here-in-before in cable trenches all as specified and directed.
Taking down old/ unserviceable lead acid battery from existing standalone solar CFL street light system located at various locations carefully etc., all as per site complete all as specified and as directed.
Supply and fixing sealed maintenance free lead acid battery 12 V, 100 AH in and including new terminals/ lugs, wiring as per site requirement complete all as specified and as directed.
Material and labour for removing of existing loop cable from under ground, after rectificattion of fault /damaged cable portion and rearrange the cable to same existing location with proper connections including lugs, nuts, bolts including PCC works etc., complete all as specified and as directed.
Supply,Fixing and Testing LED solar all-in-one-system street light luminaire fitting of not less than 30 Watt including fixing arrangement etc,complete including taking down the old unserviceable/damaged light fittings and making good disturbed surfaces all as specified and directed. Make : Luker Cat- LSTSOL30N or euqivalent model of Crompton/Surya /Philips/Wipro. Note: (i) Quoted rate is deemed to be included the charges of necessary Ladder, tools and plants , necessary drilling,bolts/screws for fixing new one etc as per site requirement.and MS frame work if any complete as per site requirement. (ii)Quoted rate is deemed to be included the charges involved for the Contractor in submitting warrenty certificate for 2 years for the luminaries from manufacturer.
D.KUMAR
RK CONSTRUCTION
SUSII CONSTRUCTIONS
N SRINIVASAN
SIVA ENTERPRISES
RD ENTERPRISES
SRI VIGNESH BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .