| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹16.1 L+₹97,643.60 (6.45%)Rejected-Finance MAHALAXMI ENCLAVE OPPOSITE SLP COLLEGE MORAR GWALIOR MP | GWALIOR | GWALIOR | MADHYA PRADESH | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹16.2 L+₹1.0 L (6.80%)Rejected-Finance NARMADA COLONY BARADARI CHOURAHA MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹16.9 L+₹1.8 L (11.8%)Rejected-Finance C O PRAMOD KUMAR SHAH BUS STAND NANDPRAYAG NANDPRAYAG CHAMOLI UTTARAKHAND 246429 | NANDPRAYAG | CHAMOLI | UTTARAKHAND | 246429 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹17.0 L+₹1.9 L (12.3%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹24.8 L
EMD Value
₹50,000
Closing Date
28 Mar 2024, 6:00 pmClosed
Garrison Engineer Gwalior
Garrison Engineer Gwalior Morar Cantt
8948/GWL/E8 SPECIAL REPAIRS TO BLDG NO P-2 AND PROVISION OF SECURITY LIGHTS IN WKSP AREA AT MORAR CANTT UNDER GE GWALIOR
2024_MES_645531_1
8948/GWL/E8
Open Tender
Civil Works
Works
180 days
Garrison Engineer Gwalior
Please refer tender documents
9 documents required · 9 mandatory
₹500
Garrison Engineer Gwalior
₹50,000
Yes
25 Jul 2024
7 Mar 2024
30 Mar 2024
7 Mar 2024
28 Mar 2024
22 Mar 2024
Amount
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for Screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement plaster 1:6 complete all as specified and directed.
M&L for 25mm thick PCC (1:2:4) Type B0 (using 12.5mm graded stone aggregate) as levelling course etc complete all as specified and directed.
M&L for Non-skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but n.exc 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15mm thick in cement mortar (1:6) complete all as specified and as directed.
Same as Item No 4 but on vertical surfaces of wall set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick backing coat of CM (1:4) complete all as specified and as directed.
Dismantiling of stone slabs and tiles of any discription or any thickness in floors, aprons, skirting, dado etc laid bedded and pointed in any mortar complete all as specified and directed.
M&L for machine cut Kota stone slab 20 mm to 25 mm thick, as in flooring, laid over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing over and including 15 mm thick screed bed in cement mortar (1:6 ) complete all as specified and directed.
M&L for machine cut Kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar laid over & including 10mm thick backing coat of CM 1:4 and jointed complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for 15mm thick rendering on brick or stone/concrete any surfaces in cement mortar (1: 4) on mixed with WPC @ 3% by weight of cement, surface finished even and smooth without using extra cement complete all as specified and directed. Note : WPC shall be measured & paid seperately.
Supply only liquid water proofing compound (ISI marked) complete all as specified and directed.
M&L for 10 mm thick rendering in cement mortar on fair faces of brick work or concrete surfaces in cement mortar (1:6) and surface finished even and smooth, complete all as specified and directed.
Preparation of new plaster surfaces of wall, and applying two coats of distemper oil emulsion over a coat of 1mm thick wall putty & over a coat of chalk whiting, on plastered surfaces complete all as specified and directed.
M&L for Preparation of new plaster surfaces of wall, and applying two coats of cement base paint over priming coat of alkali resistant primer complete all as specified and directed.
Preparation old surfaces of wall including, complete removal of existing treatment by scraping through iron strips & as directed in SSR complete all as specified and directed.
M&L for applying 2-3 mm wall care putty on walls and applying two coats oil emulsion distemper over a coat of primer complete all as specified and directed.
M&L for applying one coat of cement base paint complete all as specified and directed.
Taking down Chowkats or frames size not exceeding 1.5 sqm each (Without taking off shutters from the frames) complete all as specified and directed.
Taking down Chowkats or frames size exceeding 1.5 Sqm but not exceeding 4 Sqm each (Without taking off shutters from the frame) complete all as specified and directed.
S&F for pressed steel frame of size 125mm x 60 mm for door with one or more rebates makaing necessary fixing lugs, higes, lock strike plate, etc complete all as specified and directed.
S&F for 35 mm thick factory made shutter, Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F for 35 mm thick skeleton shutters of 2nd class Hard Wood, open rebated and prepare to reveive glass, guage etc (without sash bars ) edges of framing plain chamfered or rounded, fitted with for securing glass etc, size of members of shutters as specified in SSR Pt-I, section 8, clause 8.24(a) complete all as specified and directed.
M&L for providing cement concrete (1:3:6) type C1 (using 20 mm graded stone aggregate) as filling inside pressed steel frame complete all as specified and directed.
S&F for Box type steel windows with side hung shutters (double shutters for glass and guaze) jointed together with an including grills using 10mm square bars @10 cm C/C as per TD No CEBZ/TD/14/2011 including box type hinges with steel handle and steel peg stay complete with glazing bars devetailed and welded making a good complete all as specified and as directed. Note : Glass/guage shall be measured and paid separately under respective item.
S&F in renewal for 3mm thick, sheet glass, ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane including hacking out old broken glass of any thickness and any description from wooden/ steel frame/ stone, concrete or brick surrounds complete all as specified and directed.
S&F in renewal of galvanised wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanised staples complete all as specified and directed.
S&F in renewal Curtain rail anodised aluminium alloy, chroium plated orative type 20-25 mm dia including fixing brackets and decorative end knobs complete all as specified and directed.
S&F for Butt hinges, 100 mm size extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed complete all as specified and directed.
S&F for 200mm size aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F for Aluminium handles, cast type anodised of Size 150mm complete all as specified and directed.
S&F 300 mm size aluminium alloy anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections or cast aluminium alloy complete all as specified and directed.
S&F in renewal of 140mm size Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring complete all as specified and directed.
Taking down eaves gutters and rain water pipes (any size 75mm to 110mm of any pattern), of any description and in any position, including all fittings, heads, shoes, bends, swan necks, etc (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed.
S&F in renewal of 110 mm dia PVC (SWR ) pipes single socketed in any length with rubber ring joints laid in floor or fixed on wall with necessary clamp complete all as specified and directed.
M&L for 75 mm thick PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in plinth protection/path and the like including finsihing even & fair complete all as specified and directed.
M&L for 100 mm thick PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate), as in sub base for floor, finished even and rough complete all as specified and directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for 60 mm thickness rubber moulded machine pressed precast concrete interlocking paver block with pigment M-35 any shape and size, confirming to IS 15658-2006 in grey cement glossy finish rubber moulded casted laid dry over sand cushioning complete all as specified and directed.
Taking down carefully existing aluminum/copper point wiring (light, fan, socket or power point) complete of any description including fitting such as switches, ceiling roses, pendants, tube light fitting, ceiling fan with regulators, sockets, wooden boards, laminated sheets from sunken boxes, boards, shades light fitting etc and making good the disturbed surfaces of walls, floors, ceiling etc to match with existing surfaces complete all as specified and directed.
Taking down ceiling fan of any sweep, removing blades, cleaning the fan completely of dust and dirt and Re-hanging the same back to its original positions including connecting with three core flexible copper wire to ceiling rose etc after the completion of the point wiring including renewal of old unserviceable fan hook rubber pad, nut bolts and washers etc complete all as specified and as directed.
Taking down submain wiring of any size any type and in any position metalic/non metallic PVC conduit or of wooden batten complete all as specified and directed.
Taking down unserviceable Sheet metal box & MCB DB SPN with MCB's of any make/capacity complete all as specified and directed.
Taking down unserviceable TPN DB with MCB's of any make/capacity, complete all as specified and directed.
M&L for concealed point wiring with PVC insulated and unsheathed electric cable 1100 volts grade single core FRLSH confirming to IS 694:2010 having multi stranded copper conductor of 1.5 Sqmm nominal cross sectional area (ISI marked with valid CML No) drawn in and including concealed non metallic rigid PVC conduit medium grade( ISI marked with valid CML No) not less than 20 mm dia with all fitting and fixing accessories and 1.5 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor, connected to common earth dolly by providing suitable lugs with & including pressed steel Metal flash boxes factory made for mounting modular switch, regulators, socket etc with and including 2.8 mm thick plastic laminated sheet cover (white) ISI marked, fixed with brass screws and cup washers duly painted with two coats of anti corrosive paint/black bituminous paint outside and two coats of aluminium paint inside for mounting modular switches sockets etc complete for the following:-
One light point controlled by one switch.
One Ceiling fan point controlled by one switch.
One Exhaust fan point controlled by one switch.
One 5 pin multipurpose socket out let 5/6 Amps on the same board with other switch.
One 3 pin/5 pin switch socket outlet, 5 Amps on independent board.
Description all as per item No 44 here in before but point wiring with 2.5 sqmm FRLSH H confirming to IS 694:2010, multistrand copper conductor cable for one six pin socket outlet 15 Amps controlled by one switch on independent board and 2.5 sqmm FRLSH PVC insulated multi strand copper conductor cable as continous earth wire complete all as specified and directed.
S&F Modular switch 1 way 6A,1 module complete all as specified and directed.
S&F Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed.
S&F Modular switch 1 way 16A, 1 module 15 Amp complete all as specified and directed.
S&F Socket 6A/16A-2/3 pin combined 2 module complete all as specified and directed.
S&F ceiling rose surface bakelite 63.5 mm dia three terminal complete all as specified and directed.
S&F Fan step regulator, 120W - 2 module 240 volts, AC 50Hz complete all as specified and directed.
S&F Lamp holder with metal ring, PVC/Polycarbonate type with back plate suitable for batten fittings ISI Marked complete all as specified and directed.
S&F LED Lamp 09/10, efficiency > 130 lumen/watt complete with 5 star rating complete all as specified and directed.
M&L for sub main wiring with two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 6 sqmm size drawn in and including non metallic rigid PVC concealed conduit medium grade confirming to IS 14930 (Part-I) 2001, (ISI marked with valid CML No) not less than 25 mm dia with all fitting & fixing accessories including one run single core PVC insulated unsheathed 4 Sqmm FRLSH copper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upto DB complete all as specified and directed. (NOTE: (i) Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit and the quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface with putty to match with the existing surface.
M&L for sub main wiring with two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No) cable 1100 Volt grade, 4 sqmm size drawn in and including non metallic rigid PVC concealed conduit medium grade (ISI marked with valid CML No) not less than 25 mm dia with all fitting & fixing accessories including one run single core PVC insulated unsheathed 4 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, copper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upto DB complete all as specified and directed. (NOTE: (i) Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit and the quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface with putty to match with the existing surface.
S&F for Decorative ultra slim LED Tubelight fitting of LED with extruded polycarbonate, enviormental friendly energy efficient ready to use, 20 watt, 6500K fitting, Efficiency >100 lumen /watt incluing reqd length of not less than 1.0 Sqmm PVC multistranded BIS marked 03/02 core copper conductor for electrical connection from ceiling rose to connector of LED fitting including testing on completion all as specified and directed.
S&F BLDG LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including reqd length of 1.5 Sqmm PVC multistranded BIS marked, 03 core copper conductor for connection from ceiling rose to light fittings including testing on completion complete all as specified and directed.
M&L for bending & shaping of 40 mm dia galvanised iron pipe light grade over all length 0.60 mtr including necessary clamps, brackets and bolts mtr etc to fixed on wall/pole as per site requirement including fixing on pole with light fittings complete all as specified and directed.
S&F in renewal sheet metal enclosure double door for distribution board factory made for MCB DB load link VTPN 4 way suitable for MCCB as incomer, 100 Amp, 4 pole & Including MCCB 100 amps 4 pole 16 KA complete (when MCB's are to be used) with suitable size of busbar complete, fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification complete all as specified and directed.
S&F MCB DB, sheet metal enclosures double door SPN 8 way with 200 Amps rated bus bar 240 volts 2 in 1 shutter type (METAL DOOR) type with blanking plates where required and IP 43 degree protection complete all as specified and directed.
S&F, MCB SPN 63 Amps, 240 volts 'C' series 16 KA, including connection with suitable size copper lugs complete all as specified and directed.
S&F MCB SP 240 volts, 6 to 32 Amps, 'C' series 10 KA including connection with suitable size copper lugs complete all as specified and directed.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amp complete all as specified and directed.
Supplying, laying, testing and commissioning of XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (Heavy duty) with aluminium conductor 1100 volts grade, cross sectional area of size 35 Sqmm 3.5 Core complete all as specified and directed.
Excavation in trenches n exc 1.5 m wide and n.exc. 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
Returning, filling of excavated soil, including spreading leveling, watering and well ramming in layers, not exceeding 25cm thick each layer complete all as specified and directed.
Removing of surplus soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
Sand filling in trenches with clean dry unwashed sand free from sharp particles, gently punning around the cables complete all as specified and directed.
Supplying and laying un reinforced precast concrete cable cover Class LV, Type I, flat of size 250mm x 150mm x 40mm complete all as specified and directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for INDOOR joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Aluminium conductor cable of size 25 to 50 sqmm Indoor/Outdoor type complete all as specified and directed.
S&F tube 'Light' grade galvanised with all fitting laid in trenches, fixed to wall and floor of 50 mm dia for cable protection complete all as specified and directed.
S&F for modular plate of different size including fixing, the modular switchs, modular socket, modulare regulator complete all as specified and directed.
White cover plate with frame but 2/3/4 module
White cover plate with frame but 6 module
White cover plate with frame but 8/12 module
M&L for Steel tublar swaged poles, complete with cast iron base plate, finials taper plug , bolts, nuts & screws as specified type 410 SP-31 (9.00 mtr long) complete all as specified and directed. Note : Earth work and PCC shall be measured & paid separately under respective items .
Supply and fixing LED flood light of 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Supply and fix ACSR Aluminium conductor (Squirrel) complete all as specified and directed.
S&F Stay assembly complete with accessories as shown in electrical plate No. 1 (loop type insulator, stay clamps, excavation and concrete measured separately) with stay rod of size 16 mm complete all as specified and directed.
M&L for Galvanised steel wire 3.15 or 4mm dia stranded 7/1.6mm complete all as specified and directed.
M&L for Loop type insulator, vitreous porcelain, white, brown or green Small size with overall dimensions 65mm x 90mm, clearance of hole 16mm complete all as specified and directed.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4mm dia galvanised iron or steel wire complete all as specified and directed.
S&F Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 50mm height, 65mm dia for 550 volts grade complete all as specified and directed.
S&F Shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts of size dia 90mm and height 75mm of 1100 Volt complete all as specified and directed.
M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat & two coats of synthatice enamel paint complete all as specified and directed.
Supplying, laying, testing and commissioning of XLPE insulated screened PVC bedded galvanised steel strip or wire armured electric power cable (Heavy duty) with aluminium conductor 1100 volts grade of cross sectional area 16 Sqmm 2 Core complete all as specified and directed.
M&L in renewal for Cable joining kit for LT cable for outdoor termination heat shrink type joint complete with joining material and accessories suitable for 2 core XLPE armoured aluminium conductor cable of size 10 sqmm to 16 sqmm complete all as specified and directed.
S&F tube 'Light' grade galvanised Pipe of 40 mm dia with all fitting for cable protection, laid in trenches, fixed to wall and floor by MS shaddle & fixed with pole, 02 position by MS clamp made of MS flat iron of size 40x5 mm, complete all as specified and directed.
Boring of holes under road, pavement, hard standing by trenches technology up to size 80mm complete all as specified and directed.
Excavation in trenches exc 1.5 m wide and exc 1.5m deep and n.exc 3.0 m deep for foundation also for beyond the first 1.5 m etc or for shafts, wells cesspits, manholes, pier holes, etc n.exc 10 sqm on plan and getting out in soft/loose soil complete all as specified and directed.
M&L for PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete all as specified and directed.
M&L for PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M&L for PCC (1:2:4) type B-0 (using 12.5 mm graded BT stone aggregate) as in bed block for hold fast or coping including necessary form work complete all as specified and directed.
Supply and installation of Chemical earthing electrode 3.0 mtr length, galvanised outer dia 88mm and inner dia 48mm and the cavity between the rod pipes filled with ground resistance improment powder, sealed with both end the outer pipe of electrode should be Zink coated, the electrode should buried directly in ground by making boring of diameter 10" with boaring machine highly connected with GI strip of size 25mmx3mm of 2 to 3 mtr length to facilitet further connection to earth dolly and provision of earthing chamber in bricks wall of size 45x45x15 cm and having PCC cover made out PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) of required size complete all as specified and directed. and all as per IS 3034(1981).
S&F Photometric sensor outdoor type 220-240 volt ambient light <5-15 lux working temparature -20~+40C working humidity <93% RH along with PVC connection of 6 to 10 amp capacity complete all as specified and directed.
M.S. ENGINEERS
M/s Tirupati construction
M/S SANJAY AGARWAL
mahamaya constructions
lodhi builders
Jai Mahakaal Construction
Akarsha Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .