Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
25 Feb 2025, 6:00 pmClosed
GE(I R AND D RCI, HYDERABAD
GE(I) RND RCI, MILITARY ENGINEER SERVICES, VIGNYANAKANCHA, RCI, HYDERABAD
MAINT OF DUCTABLE PACKAGE ACS SPLIT TYPE ACS AND COOLING APPLIANCES AT RCI ELSEC CPDC UNDER GE I RD RCI HYDERABAD
2025_MES_695232_1
8238
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
GE(I) R AND D RCI
MES enlisted Class D category c i Un enlisted Meeting enlistment criteria of D class in MES and having no recovery pending. For further details ref NIT
8 documents required · 8 mandatory
₹500
Yes
GE(I) R AND D RCI, HYDERABAD
₹80,000
Yes
4 Mar 2025
28 Jan 2025
27 Feb 2025
28 Jan 2025
25 Feb 2025
11 Feb 2025
Amount
Supply and fix as in replacement FR PVC insulated, round sheathed 3 core 2.5 Sqmm, multistranded copper conductor industrial cable, 1100V grade, ISI marked drawn through and including PVC Conduit or PVC casing & capping, medium grade, of suitable size (ISI marked) along with accessories fixed on walls/roofs/floors etc, Make: Havells/Gloster/Finolex
Supply and fix as in replacement FR PVC insulated, round sheathed 4 core 2.5 Sqmm, multistranded copper conductor industrial cable, 1100V grade, ISI marked drawn through and including PVC Conduit or PVC casing & capping, medium grade, of suitable size (ISI marked) along with accessories fixed on walls/roofs/floors etc, Make: Havells/Gloster/Finolex
Supply and fix Sub main wiring with 4 core 4.0 Sqmm 1100 Volts grade, FRLSH PVC insulated, unsheathed cable, copper conductor, multistranded drawn through and including PVC Conduit or PVC casing & capping, medium grade, of suitable size (ISI marked) along with accessories fixed on walls/roofs/floors etc, including provision of FRLSH PVC insulated 4.0 sqmm copper conductor as earth continuity conductor and connecting to common earth dolly complete all as specified and directed. NOTE: Two runs of cable, one run of earth continuity conductor and one run of PVC Conduit/PVC casing and capping shall be measured as one unit length.
Supply only as in replacement MCB, SP, 20 Amps, 10KA, 240 Volts, ISI marked. MAKE: Legrand / Havells / Siemens / L&T / IndoAsian / C&S OR equivalent as approved by GE.
Supply only as in replacement MCB, SP, 25 Amps, 10KA, 240 Volts, ISI marked. MAKE: Legrand / Havells / Siemens / L&T / IndoAsian / C&S OR equivalent as approved by GE.
Supply only as in replacement MCB, SP, 32Amps, 10KA, 240 Volts, ISI marked. MAKE: Legrand / Havells / Siemens / L&T / IndoAsian / C&S OR equivalent as approved by GE.
Supply only as in replacement single pole and neutral sheet metal enclosure with a two pin and earth plug & socket complete with and including one single pole MCB SP 20 Amps 10KA, 240 Volts complete all as spefied. MAKE: Legrand / Havells / Siemens / L&T / IndoAsian / C&S
Supply only as in replacement remote hand set suitable for split/casette/tower/window type AC with02 nos. batteries. MAKE: LG/Hitachi/Bluestar/Voltas/OEM
Disconnecting and removing unserviceable micro processor based remote, any type with printed panel circuit board (PCB) for 3.0 to 7.0 Ton ductable Split AC from position and replacing the same with new hand set remote, cord type with printed circuit board (PCB) including connecting complete all as specified. Make: Carrier or equivalent as approved by GE
All as per item No. 9 above but for 7.5 TR to 11 TR ductable split AC.
Supply only as in replacement outdoor unit stand(floor mounted or wall mounted) made out of 19SWG mild steel powder coated sheet including provision of 06 Nos. Anchor bolts & nuts. Complete all as specified
S&F New hermetically sealed Rotary / Reciprocating compressors suitable for Split/window type air conditioner of 1.5 TR capacity, after taking down the old unserviceable compressor, with mounting assembly such as rubber springs etc., after disconnecting all electric connections, including alteration of refrigerant piping suction and discharge, pressure testing the complete system with nitrogen after carrying out repairs, flushing out the complete system, vaccumising and gas charging with R-22 refrigerant gas to obtain designed cooling closing of suction and discharge valves complete all as specified and directed. Notes: 1. The unit rate quoted shall be deemed to include for Copper Brazing rods, Nitrogen Gas, LPG Gas Tins, copper filter and capillary, pin type valves as required at site 2. Refrigerant Gas will be measured & paid separately under relevant items of this BOQ.
All as per item No. 12 above but of 2 TR capacity for split/window/casette type air conditioner.
All as per item No. 12 above but of capacity 2.5 TR for cassette type air conditioner.
All as per item No. 12 above but of capacity 3.4/4/4.5 TR for cassette type / vertical type air conditioner. Make for item No 12 to 15 : LG / Hitachi / Bluestar / Emerson / OEM
S&F new hermetically sealed scroll compressors suitable for package type air conditioner of 11 TR capacity, after taking down the old unserviceable compressor, with mounting assembly such as rubber springs etc., after disconnecting all electric connections, including alteration of refrigerant piping suction and discharge, pressure testing the complete system with nitrogen after carrying out repairs, flushing out the complete system, vaccumising and gas charging with R-22 refrigerant gas to obtain designed cooling closing of suction and discharge valves complete all as specified and directed. Notes: 1. 1. The unit rate quoted shall be deemed to include for Copper Brazing rods, Nitrogen Gas, LPG Gas Tins, copper filter and capillary, pin type valves as required at site 2. Refrigerant Gas will be measured & paid separately under relevant items of this BOQ.
All as per item No. 16 above but for 8/8.5 TR capacity package type air conditioner.
All as per item No. 16 above but for 7/7.5 TR capacity package type air conditioner.
All as per item No. 16 above but for 5/5.5 TR capacity package type air conditioner.
Supply only Refrigerant gas R-22/R- 410 A/ R-32/R- 134 A. ( split/window/casette/tower/ductable/packaged)
Supply only Refrigerant gas R- 404 (cold storage)
Supply only as in replacement Starting Capacitor 80/100 or100/120 MFD for split/window /water cooler compressor type of any capacity complete all as specified and directed.
Supply only as in replacement Running Capacitor 36 to 60 MFD for for compressor of split type/window air conditioners of any capacity.
Supply only as in replacement Running Capacitor of (50 + 2) & (50+4) MFD for compressor plus fan motor split type air conditioners of of any capacity complete all as specified and directed.
Supply only as in replacement Capacitor 2.5 to 10 MFD capacitor for blower motor/fan motor of split ac/window ac/water cooler/desert cooler complete all as specified and directed. Make for item Nos. 23 to 25 : Tibcon / L&T / Concap / Keltron
Supply only as in replacement PVC flexible drain pipe of 3/4'' dia.(2/3 meter length)
Supply only as in replacement balanced Centrifugal blower fan motor for split ac/window type air conditioners of any capacity
Supply only as in replacement balanced Centrifugal blower fan motor for Cassette/tower type air conditioners of any capacity
Supply only as in replacement balanced Centrifugal blower fan motor for ductable type air conditioners of any capacity
Supply only as in replacement outdoor unit brass valve of size (1/2,3/4,3/8,1/4,5/8) for any type of ac any capacity
Cleaning of water cooler of any capacity by disconnecting all electric connections, cleaning the components i.e., condenser coil, evaporating coil including inner tank with caustic soda and connecting up with electrical connections complete all as specified and directed.Notes: 1. The unit rate quoted shall be deemed to include for bleaching powder,sponz all connected items related to cleaning as required at site
S&F in repairs hermetically sealed compressors for water cooler of any capacity capacity after taking down the old unserviceable compressor, with mounting assembly such as rubber springs etc., after disconnecting all electric connections, including alteration of refrigerant piping suction and discharge, flushing out the complete system, pressure testing the complete system with nitrogen after carrying out repairs, vaccumising and gas charging with refrigerant gas to obtain designed cooling closing of suction and discharge valves complete all as specified and directed. Notes: 1. The unit rate quoted shall be deemed to include for Copper Brazing rods, Nitrogen Gas, LPG Gas Tins, copper filter and capillary, pin type valves as required at site 2. Refrigerant Gas will be measured & paid separately under relevant items of this BOQ.
Servicing of split type / cassette/window /tower type Air conditioner unit of any capacity by disconnecting all electrical connections, cleaning components i.e. condenser coil and evaporating coil by air blower to remove the dust and dirt and cleaning with caustic soda / Coil cleaner for cleaning the Outdoor unit / Indoor unit & air filters complete all as specified and directed. Note: 1. The unit rate quoted shall be deemed to include for necessary caustic soda / coil cleaner etc.
Servicing of Ductable/packaged type Air conditioner unit of any capacity by disconnecting all electrical connections, cleaning components i.e. condenser coil and evaporating coil by air blower to remove the dust and dirt and cleaning with caustic soda / Coil cleaner for cleaning the Outdoor unit / Indoor unit & air filters complete all as specified and directed. Note: 1. The unit rate quoted shall be deemed to include for necessary caustic soda / coil cleaner etc.
Supply only as in replacement PVC / Fiber fan blade for condensor motor of Air conditioners of capacity 1.5 TR to 4.5 TR complete all as specified.
Supply only as in replacement Metallic fan blade for condensor motor of Air conditioners of capacity 1.5 TR to 4.5 TR complete all as specified.
Supply only as in replacement Over Load Protector suitable for water coolers of any capacities. complete all as specified. Make: Annnapurna/ Arvind/Ranutral (As per OEM)
Supply only as in replacement Fan Motor Blade metallic for Ductable type AC Units of any make, capacity 5 to 7.5 TR complete all as specified.
Supply only as in replacement Fan Motor Blade metallic for Ductable type AC Units of any make, capacity 8.5 to 11 TR complete all as specified.
Supply only as in replacement Fan Motor for the water cooler of any make/capacity complete all as specified. (As per OEM) Make: Truemax/AUE/OR Equivalent approved by GE.
Supply only as in replacement brass chromium plated Push/Lifting Cock inner/outer thread for water cooler complete all as specified. Make: Jayson/HMP/Viking
Flushing out complete refrigerant system, charging refrigerant gas including replacement of capillary tube and ‘U’ foam with new ones, cutting, brazing, leak detection and rectification in the entire system and commissioning the water cooler of any capacity complete all as specified and directed. Notes: 1. The unit rate quoted shall be deemed to include for Copper Brazing rods, LPG Gas Tins , Nitrogen Gas with cylinder shall be arranged by contractor. 2. Refrigerant Gas will be measured & paid separately under relevant items of this BOQ.
Leak testing of complete gas circulating system with dry nitrogen for a period of 24 hours, flushing out complete system, vacuumising, and charging refrigerant gas including replacement of unserviceable copper filter, capillary tube, ‘U’ foam etc., with new ones, cutting, brazing, leak detection and rectification etc., for any type Air Conditioner of capacity 1.5 to 4.5 TR complete all as specified and directed. Notes: 1. The unit rate quoted shall be deemed to include for Copper Brazing rods, Nitrogen Gas, LPG Gas Tins and all connected items required as per site requirement. 2. Refrigerant Gas will be measured & paid separately under relevant items of this BOQ. 3. Labour work required to complete the job shall be done through outsourcing employees.
All as per item No.43 above but for 5 to 11 Ton capacity air conditioner.
Cleaning of evaporator coil of 1.5 to 4.5 TR capacity any type of Air Conditioner with approved cleaning acid recommended by manufacturer by forced feed method to remove all the dust particles deposited on the coil and fins, cleaning of the filters, greasing to AHU bearings of liquid lines, strainer, expansion valves etc., and testing complete all as specified and directed. Note: The unit rate quoted shall be deemed to include for necessary cleaning Acid / coil cleaner etc.
All as per item No. 45 above but for 5.5 to 11 TR capacity.
Supply only as in replacement new catch all filter (Dry filter) suitable for 5 TR to 7.5 TR capacity any type of Air Conditioner. Make: Carrier/Danfoss/as per OEM
Supply only as in replacement new catch all filter (Dry filter) suitable for 8 TR 11 TR capacity any type of Air Conditioner. . Make: Carrier/Danfoss/as per OEM
Disconnecting electrical connections, pumping down complete system, and removing split type AC of 1.5/2 ton capacity including copper pipe from the existing position and shifting the same to the new location, re-connecting the AC after making suitable hole in the wall, flushing out complete system, pressure testing complete system with nitrogen after fixing, vacuumising topping up refrigerant gas to obtain designed cooling closing of suction and discharge valves, providing necessary connections, including closing the hole with cement mortar and finishing surfaces to match with the existing complete all as specified and directed. Notes: 1. The unit rate quoted shall deemed to include for screws, wooden gutties, brazing rods, cement mortar, Nitrogen gas, nurt bolts. 2. Copper pipe line, Electrical cable, Refrigerant Gas will be measured & paid separately under relevant items of this BOQ.
Supply only as in replacement Air Filter indigenous washable type suitable for any type air conditioners of 1.5 to 4.5Ton capacity. Make: As per OEM
Supply only as in replacement Air Filter indigenous washable type suitable for any type air conditioners of 5 to 11 Ton capacity. Make: As per OEM
Supply only 22 OIL
Supply only as in replacement Indoor Unit with all accessories suitable for 1.5 ton capacity any type AC including cutting, brazing, leak testing, reconnecting and testing. Make: Crompton Greaves/Voltas/Blue Star/Carrier /OEM
Supply only as in replacement Indoor Unit with all accessories suitable for 2 ton capacity any type AC including cutting, brazing, leak testing, reconnecting and testing. Make: Crompton Greaves/Voltas/Blue Star/Carrier /OEM
Supply only as in replacement Copper pipe of size 1/4" including tubular heat/cold resistant rubber / foam type insulation.
All as per Sl Item No. 55 above, but of size 3/8''.
All as per Sl Item No. 55 above, but of size 1/2''.
All as per Sl Item No. 55 above, but of size 5/8''.
All as per Sl Item No. 55 above, but of size 3/4''.
Taking down unserviceable printed circuit board (PCB) of 1.5 to 4.5 Ton capacity of any type AC by disconnecting all electrical connections, repairing the same and connecting up, testing and commissioning complete all as specified and directed.
Taking down unserviceable printed circuit board (PCB) of 5 to 11 Ton capacity of any type AC by disconnecting all electrical connections, repairing the same and connecting up, testing and commissioning complete all as specified and directed.
Supply only as in replacement Printed Circuit Board (PCB) with remote set suitable for 1.5 to 4.5 Ton capacity of any type AC Make: Voltas/Carrier/Blue Star/LG/Hitachi
Supply only as in replacement Printed Circuit Board (PCB) with remote set suitable for 5 to 11 Ton capacity of any type AC Make: Voltas/Carrier/Blue Star/LG/Hitachi
Supply only as in replacement Potential relay for split type ac/window ac/water cooler
Supply only as in replacement 'V' belts of any size required for ductable /packaged type ac aa per site requirement Make : Dunlop/Fenner/PIX/ Continental
Supply only as in replacement Voltage Stabilizer 4 KVA for Split type AC's of 1.5 TR capacity. Make: Softline/Havells
Supply only as in replacement Voltage Stabilizer 5 KVA for Split type AC's of 2.0 TR capacity. Make: Softline/Havells
Supply only as in replacement room sensor suitable for cassette type AC.
Supply only as in replacement Drain Pump Motor suitable for cassette ac/water cooler of any capacity
Supply only 3 phase voltage scanners. Make: Carrier / minilec
Supply only as in replacement over load relay range from 6 to 10 Amps, 415 Volts.
Supply only as in replacement Single phase preventor, VSP 2, 415V complete all as specified. Make: Minilec/Powertek/GIC.
Supply only as in replacement over load relay range from 9 to 15/14 to 26 Amps, 415 Volts. Make: Havells/L&T/IndoAsian/ Siemens/C&S
Supply only 134 OIL
Disconnecting electrically and dismounting fan motors of any capacity of ductable ac from existing position, re-winding with super enamelled copper wire of existing gauge and turns duly insulated, varnishing, replacing the worn-out bearings, greasing and fixing back in original position, connecting up and testing complete all as directed. Note: Labour work required to complete the job shall be done through outsourcing employees.
Disconnecting electrically and dismounting fan motors of any capacity of split/window/water cooler/casette/towwer ac from existing position, re-winding with super enamelled copper wire of existing gauge and turns duly insulated, varnishing, replacing the worn-out bearings, greasing and fixing back in original position, connecting up and testing complete all as directed. Note: Labour work required to complete the job shall be done through outsourcing employees.
Supply only as in replacement copper condenser coil of any size for split type AC of 1.5/2 Ton capacity. Make: As per OEM
Supply only as in replacement Thermostat switch including knob plate for water cooler of any capacity complete all as specified. Make: ANNAPURNA/ RANUTROL/ INDOFOSS as per OEM
Supply only as in replacement 15mm bore float valves, high pressure, with polythene float and fly nut for water cooler of any capacity complete all as specified.
Supply only as in replacement 15mm bore PVC connection heavy duty with brass nuts, 600mm length, for water coolers complete all as specified. Make: KOHINOOR/MAHAVIRA/HB
Supply only as in replacement 3 pole contactor AC3, MNX type rating of 415 volts, 25 Amps for complete all as specified
Supply only as in replacement 3 pole contactor AC3, MNX type rating of 415 volts, 18/12 Amps.
Supply only as in replacement single ploe/2 pole contactor for split type AC. Make: L&T CAT No CS90234 or equivalent in Legrand / Siemens / ABB / Schneider
Supply only as in replacement brass dummy nuts of existing size for any type AC.
Supply only as in replacement brass Flare Nuts of existing size for any type AC.
Supply only as in replacement suction discharge brass valve of any size for any type AC.
Supply only as in replacement Insulation felt / foam insulation any size for sany type AC, copper piping tube inlet / outlet to out door unit approx 2.5 metre length.
Supply only pvc pipe 1 or 1/2 inch size for drain pipe connection including all type fitting,clamps.
S&F 63 Amp HRC fuse complete all as directed.
All as per item No 89 above but 32 Amp capacity. Make for item no 89,90: Standard / L&T/ Havells / C&S / Schneider.
Supply only coil shine cleaner.
Supply only as in replacement Printed Circuit Board (PCB) with remote set suitable for 1.5 /2 Ton capacity of any invertesr type AC Make: Voltas/Carrier/Blue Star/LG/Hitachi
S.S.ENGINEERING CORPORATION (BID ID -3238307)
CHITRA ENGINEERING CORPORATION (BID ID -3238345)
Bismi Engineering (BID ID -3242735)
EXELLENT POWER CORPORATION (BID ID -3242797)
SANTHAM TRADERS (BID ID -3249329)
M/S J J ENTERPRISES (BID ID -3242579)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .