Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.7 LAccepted-AOC AT BONGA ITKHORI CHATRA | CHATRA | JHARKHAND | 825103 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹3.4 L+₹29,837.14 (9.57%)Rejected-Finance PLOT NO 06 GODHANI ROAD WELCOME HOUSING SOCIETY RASHTRASANT NAGAR NAGPUR 440030 | NAGPUR | NAGPUR | MAHARASHTRA | 440030 | L2 | Rejected-Finance Not Being L1 |
Tender Value
₹4.4 L
EMD Value
₹5,500
Closing Date
7 Nov 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Staff Officer (C)
Staff Officer (C) G.M. Office Bishrampur Area
Construction of First Aid Centre at Amera OCP of Bishrampur Area.
2022_SECL_259522_1
GM/BSPR/Civil/e-tender/ 2022-23/28 Dt.17.10.2022
Open Tender
Civil Works - Buildings
Item Rate
90 days
Amera Sub Area
As Per NIT
3 documents required · 3 mandatory
₹5,500
17 Dec 2022
18 Oct 2022
9 Nov 2022
18 Oct 2022
7 Nov 2022
19 Oct 2022
18 Oct 2022 - 26 Oct 2022
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Supplying and filling in plinth with local sand under floors, including watering, ramming, consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size).
Brick work with Fly Ash bricks of class designation-35 in foundation and plinth in : cement mortar 1:6 (1 cement : 6 coarse Sand).
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form for : Weather shade, chajjas, corbels etc., including edges.
Centering and shuttering including strutting, propping etc. and removal of form for : Edges of slab and breaks in floors and walls..Under 20cm wide
Brick work with Fly ash bricks of class designation-35 in superstructure above plinth level upto floor five level in all shapes and sizes in : cement mortar 1:6 ( 1 cement : 6 coarse sand)
Half brick masonry with Fly ashClass designation 35 in infoundation and plinth. Cement mortar in 1:4 (1 cement : 4 coarse sand).
Providing, hoisting and fixing upto floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like including the cost of required centering, shuttering, finished smooth with 6 mm thick cement plaster 1:3 ( 1 cement: 3 fine sand), on exposed surfaces but excluding the cost of reinforcement with 1:2:4 ( 1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. Mild steel and Medium Tensile steel bars.
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make , in all coloursand shade, laid on 20mm thick cement mortar1:4 including grouting the joints with white cement and matching pigments etc. complete : Size of tiles 600 x 600mm
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (Make Kajariya / Johnson or Equivalent)
12 mm cement plaster finished with a floating coat of neat cementof mix : 1:4 (1 cement: 4 fine sand)
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces
Providing and fixing ISI marked M.S. Pressed butt hinges bright finished with necessary screws etc. Complete: 125 x 65 x 2.12mm
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
Finishing with deluxe multi surface paint system for interiors and exteriors using primer as per manufacturer specification : Two or more coat applied on walls @ 1.25 ltr /10sqm over and including one coat of special primr applied @ 0.75ltr /10sqm
Finishing walls with premium acrylic exterior paint with silicone additives of equired shade : New work (Two or more coats applied @1.43 ltr /10sqm over and including priming coat of exterior primer applied @ 2.20 kg/10sqm)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new workDoor & Window
Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
Providing and fixing white vitreous lavoratory sink..450x300x150..
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe - 32 mm dia.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. : Internal work – Exposed on wall.20 mm dia. nominal bore
Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 25mm nominal bore, weighing not less than 62 gms
Providing and fixing C.P. brass BIB cock of standard design and of approved make conforming to IS:8931. 15 mm nominal bore.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes. 110 mm diameter.
Providing and fixing on wall face unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes confirming to IS: 13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10 mm gap for thermal expansion. Bend 87.5°. 110 mm bend.
Constructing soak pit 1.20x1.20x1.20 filled with brick bats includingS.W drainpipe and 1.20m long complete as per standard design
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. SHORT POINT OR Type A
POINT WIRING WITH PVC INSULATED CABLE WITH COPPERCONDUCTOR 1.5 SQMM ISI MARKED IN SURFACE RIGID PVC NON METALLIC CONDUIT OF SUITABLE SIZE ISI MARKED AS REQUIRED AS PER SPECIFICATION FOR SHORT POINT, 3 PIN 5 AMPERE SOCKET OUT LET POINT ON SEPARATE BOARD.
POINT WIRING FOR 3 PIN-15 AMPERE SOCKET OUT LET POINT WITH PVC INSULATED CABLE WITH COPPER CONDUCTOR 4 SQMM ISI MARKED15 AMPERE FT SWITCH ETC IN SUITABLE SIZE OF THE RIGID PVCINSULATED NON METALLIC CONDUIT ISI MARKED INCLUDING4 SQ MM COPPER EARTH CONTINUITY CONDUCTOR IN SURFACE CONDUIT WIRING SYSTEMAS PERSPECIFICATION ( on seperate board ) SHORT POINT,
Wiring for sub main with pvc insulated cable with copper conductor 2 x2.5 sq mm in 20 mm pvc conduit casing caping i/c connection painting etc.
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 32 Amp TP&N
Total impact of GST for the purpose of CTC
ADITYA CONSTRUCTION
stage.html
html • 0.04 MB
techsummary_268424.pdf
PDF • 2.52 MB
finsummary_268424.pdf
PDF • 2.52 MB
AOC28.pdf
PDF • 4.85 MB
finance_268424.pdf
PDF • 0.02 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .