Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹64.1 LAdmitted-Finance | ₹64.1 L | L1 | Admitted-Finance |
| 2 | L2₹1.1 CrAdmitted-Finance A 274 6TH MAIN ROAD 2ND STAGE PEENYA INDUSTRIAL AREA BANGALORE KARNATAKA 560058 UDYAM KR 03 0008419 29AAICA6231C1ZX R M MII STATUS AS NOT VERIFIED | BENGALURU URBAN | KARNATAKA | 560058 | ₹1.1 Cr | L2 | Admitted-Finance |
| 3 | L3₹1.3 CrAdmitted-Finance G1 12 INDEXEL ENGINEERING ROAD NO 4 I P I A KOTA KOTA RAJASTHAN 324005 UDYAM RJ 24 0006878 08AADCI0760M1ZF R M MII STATUS AS VERIFIED | KOTA | RAJASTHAN | 324005 | ₹1.3 Cr | L3 | Admitted-Finance |
| 4 | Rejected-Technical | - | - | Rejected-Technical Technically Not Qualified |
| 5 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical EMD/Fee not received |
| Sl No | Description | Qty | Unit | Indexel Engineering Pvt. Ltd. L3 | Adarsha Control and Automation Pvt Ltd. L2 | CORONET ENGINEERS P LTD L1 |
|---|---|---|---|---|---|---|
| 1.00Supply of Item: | ||||||
| 1.01 | PLC (Hot standby model) for 700 I/Os with PLC prg.S/w and license -1no. (Refer Section-VII, spec-1) | 1 | set | 32,72,000 ₹32.7 L | 30,62,020 ₹30.6 L | 17,99,266 ₹18.0 L |
| 1.02 | SCADA:
a. Full Server SCADA-1no.with license.
b. Full Client SCADA-1no. with licence.
c. PCs of latest Windows OS -2nos.
d. A3 size printer-1no.
e. N/W switch-4no.
f. UPS -2nos.
g. Operator console to house above items.-1no.
(Refer Section-VII, spec-2 & spec-20) | 1 | set | 14,94,253 ₹14.9 L | 14,30,400 ₹14.3 L | 14,07,821 ₹14.1 L |
| 1.03 | Control panel (suitable to house the above mentioned PLC, I/O modules for 700 I/O, terminals to hook up i/o, 24VDC power supply unit, other required standard accessories)
(Refer Section-VII, spec-18) | 1 | no. | 3,33,176 ₹3.3 L | 1,75,130 ₹1.8 L | 3,28,048 ₹3.3 L |
| 1.04 | RTDs (Refer Section-VII, spec-3) | 40 | nos. | 3,471 ₹1.4 L | 1,690 ₹67,600 | 2,088 ₹83,520 |
| 1.05 | Skin RTDs (Refer Section-VII, spec-4) | 100 | nos. | 10,412 ₹10.4 L | 1,900 ₹1.9 L | 2,088 ₹2.1 L |
| 1.06 | K-type Thermocouple (Refer Section-VII, spec-5) | 20 | nos. | 8,052 ₹1.6 L | 1,690 ₹33,800 | 2,088 ₹41,760 |
| 1.07 | Signal converters for above probes (Din rail mounted) (Refer Section-VII, spec-6) | 130 | nos. | 20,824 ₹27.1 L | 15,790 ₹20.5 L | 1,740 ₹2.3 L |
| 1.08 | Pressure transmitters (Refer Section-VII, spec-7) | 27 | nos. | 44,168 ₹11.9 L | 53,050 ₹14.3 L | 25,520 ₹6.9 L |
| 1.09 | Thermal mass flow controllers in SS MOC (Refer Section-VII, spec-8) | 8 | nos. | 2,87,365 ₹23.0 L | 2,27,090 ₹18.2 L | 87,000 ₹7.0 L |
Tender Value
₹1.6 Cr
EMD Value
₹3.3 L
Closing Date
16 Aug 2022, 3:00 pmClosed
Chief Engineer, BARC, Mysore
BARC, Mysore
Supply, installation, cabling, testing and commissioning of PLC and SCADA based Control and Instrumentation Systems for a chemical plant at BARC, Mysore.
2022_BARC_688327_1
BARC/ MYS/ OMDCI/ GS/ WT-01/ 2021-22
Open Tender
Miscellaneous Works
365 days
BARC, Mysore
As mentioned in NIT Part-1, Section-V
2 documents required · 2 mandatory
₹0
₹3.3 L
BARC, Mysore
10 Jan 2023
23 May 2022
24 Aug 2022
30 May 2022
16 Aug 2022
18 Jul 2022
17 Jun 2022 - 8 Jul 2022
13 Jul 2022
Amount
Supply of Item:
PLC (Hot standby model) for 700 I/Os with PLC prg.S/w and license -1no. (Refer Section-VII, spec-1)
SCADA: a. Full Server SCADA-1no.with license. b. Full Client SCADA-1no. with licence. c. PCs of latest Windows OS -2nos. d. A3 size printer-1no. e. N/W switch-4no. f. UPS -2nos. g. Operator console to house above items.-1no. (Refer Section-VII, spec-2 & spec-20)
Control panel (suitable to house the above mentioned PLC, I/O modules for 700 I/O, terminals to hook up i/o, 24VDC power supply unit, other required standard accessories) (Refer Section-VII, spec-18)
RTDs (Refer Section-VII, spec-3)
Skin RTDs (Refer Section-VII, spec-4)
K-type Thermocouple (Refer Section-VII, spec-5)
Signal converters for above probes (Din rail mounted) (Refer Section-VII, spec-6)
Pressure transmitters (Refer Section-VII, spec-7)
Thermal mass flow controllers in SS MOC (Refer Section-VII, spec-8)
Metal tube rotameters (Refer Section-VII, spec-9)
Glass tube rotameters (Refer Section-VII, spec-10)
Orifice flow meters (Refer Section-VII, spec-11)
I to P Converters (Refer Section-VII, spec-12)
Electromagnetic flow meters (Refer Section-VII, spec-13)
HF Gas monitors (Refer Section-VII, spec-14)
H2 Gas monitors (Refer Section-VII, spec-15)
Control cables (FRLS) 3-core (Refer Section-VII, spec-16)
Control cables (FRLS) 4-core (Refer Section-VII, spec-16)
Instrument cables (FRLS) 12-pair (Refer Section-VII, spec-16)
Instrument cables (FRLS) 1-pair (Refer Section-VII, spec-16)
Instrument cables (FRLS) 2-pair (Refer Section-VII, spec-16)
T/C Compensating cables (FRLS) (Refer Section-VII, spec-16)
24 V DC Power supply (20A) (Refer Section-VII, spec-17)
JB for signal converters. (JB to house 130 temperature signal converters; Incoming signal cables from RTD /TC: 130 nos.; Outgoing cables: 11 nos. of 12-pair cables (Refer Section-VII, spec-19)
Cable glands for 3-core cables
Cable glands for 4-core cables
Cable glands for 12-pair cables
Cable glands for 1-pair cables
Cable glands for 2-pair cables
Cable glands for T/C comp cables
Lugs for cable termination
On-Site Job:
Cable laying- 3-core
Cable laying- 4-core
Cable laying- 12-pair
Cable laying- 1-pair
Cable laying- 2-pair
Cable laying- T/c comp cable
Cable glanding- 3-core
Cable glanding - 4-core
Cable glanding - 12-pair
Cable glanding - 1-pair
Cable glanding - 2-pair
Cable glanding - T/c comp cable
Cable terminations
Erection of Control panel
Erection of Junction Box
Activation of 1no. licence of PLC S/W and On-site development of PLC based interlocks (Refer Section-VII, spec-1)
Activation of licences of SCADA S/W - of server -1 no.& client -1 no. and development of screens on SACADA and Commissioning (Refer Section-VII, spec-2)
Adarsha Control and Automation Pvt Ltd.
Indexel Engineering Pvt. Ltd.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.35 MB
Tendernotice_2.pdf
PDF • 0.96 MB
Tendernotice_3.pdf
PDF • 20.71 MB
Tendernotice_4.pdf
PDF • 8.11 MB
Tendernotice_5.pdf
PDF • 0.45 MB
Tendernotice_6.pdf
PDF • 0.26 MB
Tendernotice_7.pdf
PDF • 1.07 MB
BOQ_726464.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid