Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹64.1 LAdmitted-Finance 14 INDUSTRIAL AREA TILAK NAGAR NEW DELHI BEHIND SUBASH NAGAR METRO STATION WEST DELHI DELHI 110018 | WEST DELHI | DELHI | 110018 | ₹64.1 L | L1 | Admitted-Finance |
| 2 | L2₹1.1 Cr+₹50.3 L (78.5%)Admitted-Finance 2ND STAGE BANGALORE KARNATAKA 560058 | BENGALURU URBAN | KARNATAKA | 560058 | ₹1.1 Cr+₹50.3 L (78.5%) | L2 | Admitted-Finance |
| 3 | L3₹1.3 Cr+₹69.8 L (109.0%)Admitted-Finance G1 12 INDEXEL ENGINEERING ROAD NO 4 I P I A KOTA KOTA RAJASTHAN 324005 | KOTA | RAJASTHAN | 324005 | ₹1.3 Cr+₹69.8 L (109.0%) | L3 | Admitted-Finance |
| 4 | Rejected-Technical 73 BIZNES AVENUE EDAYAPPURAM RD ALUVA ALUVA ERNAKULAM KERALA 683101 | ERNAKULAM | KERALA | 683101 | - | - | Rejected-Technical Technically Not Qualified |
| 5 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical EMD/Fee not received |
| Sl No | Description | Qty | Unit | Indexel Engineering Pvt. Ltd. L3 | Adarsha Control and Automation Pvt Ltd. L2 | CORONET ENGINEERS P LTD L1 |
|---|---|---|---|---|---|---|
| 1.00Supply of Item: | ||||||
| 1.01 | PLC (Hot standby model) for 700 I/Os with PLC prg.S/w and license -1no. (Refer Section-VII, spec-1) | 1 | set | 32,72,000 ₹32,72,000 | 30,62,020 ₹30,62,020 | 17,99,266 ₹17,99,266 Lowest |
| 1.02 | SCADA:
a. Full Server SCADA-1no.with license.
b. Full Client SCADA-1no. with licence.
c. PCs of latest Windows OS -2nos.
d. A3 size printer-1no.
e. N/W switch-4no.
f. UPS -2nos.
g. Operator console to house above items.-1no.
(Refer Section-VII, spec-2 & spec-20) | 1 | set | 14,94,253 ₹14,94,253 | 14,30,400 ₹14,30,400 | 14,07,821 ₹14,07,821 Lowest |
| 1.03 | Control panel (suitable to house the above mentioned PLC, I/O modules for 700 I/O, terminals to hook up i/o, 24VDC power supply unit, other required standard accessories)
(Refer Section-VII, spec-18) | 1 | no. | 3,33,176 ₹3,33,176 | 1,75,130 ₹1,75,130 Lowest | 3,28,048 ₹3,28,048 |
| 1.04 | RTDs (Refer Section-VII, spec-3) | 40 | nos. | 3,471 ₹1,38,840 | 1,690 ₹67,600 Lowest | 2,088 ₹83,520 |
| 1.05 | Skin RTDs (Refer Section-VII, spec-4) | 100 | nos. | 10,412 ₹10,41,200 | 1,900 ₹1,90,000 Lowest | 2,088 ₹2,08,800 |
| 1.06 | K-type Thermocouple (Refer Section-VII, spec-5) | 20 | nos. | 8,052 ₹1,61,040 | 1,690 ₹33,800 Lowest | 2,088 ₹41,760 |
| 1.07 | Signal converters for above probes (Din rail mounted) (Refer Section-VII, spec-6) | 130 | nos. | 20,824 ₹27,07,120 | 15,790 ₹20,52,700 | 1,740 ₹2,26,200 Lowest |
| 1.08 | Pressure transmitters (Refer Section-VII, spec-7) | 27 | nos. | 44,168 ₹11,92,536 | 53,050 ₹14,32,350 | 25,520 ₹6,89,040 Lowest |
| 1.09 | Thermal mass flow controllers in SS MOC (Refer Section-VII, spec-8) | 8 | nos. | 2,87,365 ₹22,98,920 | 2,27,090 ₹18,16,720 | 87,000 ₹6,96,000 Lowest |
Tender Value
₹1.6 Cr
EMD Value
₹3.3 L
Closing Date
16 Aug 2022, 3:00 pmClosed
Chief Engineer, BARC, Mysore
BARC, Mysore
Supply, installation, cabling, testing and commissioning of PLC and SCADA based Control and Instrumentation Systems for a chemical plant at BARC, Mysore.
2022_BARC_688327_1
BARC/ MYS/ OMDCI/ GS/ WT-01/ 2021-22
Open Tender
Miscellaneous Works
Works
365 days
BARC, Mysore
As mentioned in NIT Part-1, Section-V
2 documents required · 2 mandatory
₹0
₹3.3 L
BARC, Mysore
10 Jan 2023
23 May 2022
24 Aug 2022
30 May 2022
16 Aug 2022
18 Jul 2022
17 Jun 2022 - 8 Jul 2022
13 Jul 2022
Amount
Supply of Item:
PLC (Hot standby model) for 700 I/Os with PLC prg.S/w and license -1no. (Refer Section-VII, spec-1)
SCADA: a. Full Server SCADA-1no.with license. b. Full Client SCADA-1no. with licence. c. PCs of latest Windows OS -2nos. d. A3 size printer-1no. e. N/W switch-4no. f. UPS -2nos. g. Operator console to house above items.-1no. (Refer Section-VII, spec-2 & spec-20)
Control panel (suitable to house the above mentioned PLC, I/O modules for 700 I/O, terminals to hook up i/o, 24VDC power supply unit, other required standard accessories) (Refer Section-VII, spec-18)
RTDs (Refer Section-VII, spec-3)
Skin RTDs (Refer Section-VII, spec-4)
K-type Thermocouple (Refer Section-VII, spec-5)
Signal converters for above probes (Din rail mounted) (Refer Section-VII, spec-6)
Pressure transmitters (Refer Section-VII, spec-7)
Thermal mass flow controllers in SS MOC (Refer Section-VII, spec-8)
Metal tube rotameters (Refer Section-VII, spec-9)
Glass tube rotameters (Refer Section-VII, spec-10)
Orifice flow meters (Refer Section-VII, spec-11)
I to P Converters (Refer Section-VII, spec-12)
Electromagnetic flow meters (Refer Section-VII, spec-13)
HF Gas monitors (Refer Section-VII, spec-14)
H2 Gas monitors (Refer Section-VII, spec-15)
Control cables (FRLS) 3-core (Refer Section-VII, spec-16)
Control cables (FRLS) 4-core (Refer Section-VII, spec-16)
Instrument cables (FRLS) 12-pair (Refer Section-VII, spec-16)
Instrument cables (FRLS) 1-pair (Refer Section-VII, spec-16)
Instrument cables (FRLS) 2-pair (Refer Section-VII, spec-16)
T/C Compensating cables (FRLS) (Refer Section-VII, spec-16)
24 V DC Power supply (20A) (Refer Section-VII, spec-17)
JB for signal converters. (JB to house 130 temperature signal converters; Incoming signal cables from RTD /TC: 130 nos.; Outgoing cables: 11 nos. of 12-pair cables (Refer Section-VII, spec-19)
Cable glands for 3-core cables
Cable glands for 4-core cables
Cable glands for 12-pair cables
Cable glands for 1-pair cables
Cable glands for 2-pair cables
Cable glands for T/C comp cables
Lugs for cable termination
On-Site Job:
Cable laying- 3-core
Cable laying- 4-core
Cable laying- 12-pair
Cable laying- 1-pair
Cable laying- 2-pair
Cable laying- T/c comp cable
Cable glanding- 3-core
Cable glanding - 4-core
Cable glanding - 12-pair
Cable glanding - 1-pair
Cable glanding - 2-pair
Cable glanding - T/c comp cable
Cable terminations
Erection of Control panel
Erection of Junction Box
Activation of 1no. licence of PLC S/W and On-site development of PLC based interlocks (Refer Section-VII, spec-1)
Activation of licences of SCADA S/W - of server -1 no.& client -1 no. and development of screens on SACADA and Commissioning (Refer Section-VII, spec-2)
Adarsha Control and Automation Pvt Ltd.
Indexel Engineering Pvt. Ltd.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.35 MB
Tendernotice_2.pdf
PDF • 0.96 MB
Tendernotice_3.pdf
PDF • 20.71 MB
Tendernotice_4.pdf
PDF • 8.11 MB
Tendernotice_5.pdf
PDF • 0.45 MB
Tendernotice_6.pdf
PDF • 0.26 MB
Tendernotice_7.pdf
PDF • 1.07 MB
BOQ_726464.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .