Loading…
Loading…
Tender Value
₹7.9 Cr
EMD Value
₹15.9 L
Closing Date
30 Sept 2026, 3:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
SRDSTEC
14 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' which ever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet
The Tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years,ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work costing not less than the amount equal to 60% of advertised value of the tender. Note: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificate issued by any Govt. Organization, work experience certificate issue by Public listed company having average annual turnover of Rs. 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange,incorporated /registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
Defination of Similar Work :- Similar Nature of work- Any Work in connection with Signalling Installation.The work shall include indoor wiring component also if tendered work involves Indoor wiring alteration in the existing system.Note 1: Tenderer may be required to submit the schedule of those works, Completion/Performance Certificates of which have been submitted by him/her in support of 30/40 or 60 % (as the case may be) criterion of similar nature of work.
21 conditions · 13 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Covering letter duly filled by the tenderer to be submitted on their letter head as per Annexure-I of Tender Document
A copy of Authorization/Power of Attorney issued by the sole proprietor/partnership firm/LLP/ Society/JV/Company in favour of the individual to sign the tender on behalf of the sole proprietor/partnership firm/LLP/Society/JV/company as per clause no. 14 part -l of Tender Document. In case of company power of attorney must be backed by the resolution of Board of Directors and create liability against the company
Details of Plant and Machinery already available with the firm must be uploaded.
List of engineers/personnel already available/ proposed to be employed for deployment on this work must be uploaded.
Details of Beneficiary for Electronic Transfer of Funds must be uploaded.
An undertaking by sole proprietor firm/all partners of the partnership firm/Power of attorney holder if company (as per Annexure-B/C uploaded with Tender Document )or LLP or Society/JV that he/they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of opening of bids, either in their individual capacity or in any firm in which they were / are partners. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 (Part-II) of the General Conditions of Contract (as per Annexure-B/C uploaded with Tender Document). (Detail instructions/condition may be seen on Tender Document)
Please submit the copy of the registration certificate of firm, PAN, GSTIN (if applicable) etc.
Tenderers are compulsorily required to upload undertaking (attached as Annexure-A uploaded with Tender Document) regarding Employment /Partnership of Retired Railway Employees attached as Annexure 'A'. Otherwise the tenderer will give full information as to the date of retirement of such Engineer or gazetted officer from the said service and as to whether permission for taking such contract, or if the Contractor be a partnership firm or an incorporated company, to become a partner or director as the case may be, has been obtained by the tenderer or the Engineer or officer, as the case may be from the President of India or any officer, duly authorized by him in this behalf, shall be clearly stated in writing at the time of submitting the tender. Note:- Tenders without undertaking or required information shall be summarily REJECTED.
The tenderer shall clearly specify whether the tender is submitted on his own or on behalf of a partnership firm/Company/Joint Venture (JV) /Registered Society/ Registered Trust/HUF etc. The Tenderer (s) who is/ are constituents of firm, company, Association or Society shall enclose self-attested copies of the constitution of their concern, Partnership Deed, copy of PAN Card and Power of Attorney along with their tender. Tender Documents in such cases shall to be signed by such persons as may be legally competent to sign them on behalf of the firm, Company, Association, Trust or Society, as the case may be. Following documents shall be submitted by the tenderer: (a)Sole proprietor Firm: (i) Affidavit of sole proprietorship firm. (ii) All documents in terms of explanatory notes in clause 14.0 PART-I of Tender Document (b) HUF: (i) A copy of notarized affidavit on Stamp Paper declaring that he who is submitting the tender on behalf of HUF is in the position of 'Karta' of Hindu Undivided Family (HUF) and he has the authority, power and consent given by other members to act on behalf of HUF. (ii) All other documents in terms of explanatory notes in clause 14.0 PART-I of Tender Document. (c) Partnership firm, as per Tender Form-2 (Annexure-I) Para 14.10 PART-I of Tender Document: (i) A notarized copy of the Partnership Deed or a copy of the Partnership deed registered with the Registrar. (ii) A notarized or registered copy of Power of Attorney in favour of the individual to tender for the work, sign the agreement etc. and create liability against the firm. (iii) All other documents in terms of TENDER FORM -2 of Tender Document (d) Company registered under Companies Act 2013: (i) The copies of MOA (Memorandum of Association)/AOA (Articles of Association) of the company. (ii) A copy of Certificate of Incorporation. (iii) A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. (iv) All other documents in terms of explanatory notes in clause 14 PART-I of Tender Document (e) Limited Liability Society: (i) A copy of LLP Agreement (ii) A copy of Certificate of Incorporation of LLP. (iii) A copy of Power of Attorney/Authorization issued by the LLP in favour of the individual to sign the tender/MoU/JV on behalf of the LLP and create liability against the LLP. (iv) All other documents in terms of explanatory notes in clause 14 PART-I of Tender Document (f) Registered Society & Registered Trust: (i) A copy of the Certificate of Registration (ii) A copy of Memorandum of Association of Society/Trust Deed (iii) A copy of Power of Attorney in favour of the individual to sign the tender documents and create liability against the Society/Trust. (iv) A copy of Rules & Regulations of the Society. (v) All other documents in terms of explanatory notes in clause 14 PART-I of Tender Document (g) Joint Venture: All documents as specified under Para 14 PART-I of Tender Document.
No post tender correspondence for submission of additional documents shall be entertained after opening of the Technical & Commercial offers. Even suomoto post tender letters of the tenders shall be treated as NULL & Void as per Para 4.6 of STD- 2022
This tender will govern under "Indian Railway Standard General Condition of contract - 2022 or latest. Tenderers are requested to read GCC and tender document very carefully before submitting their Bid.
Performance Guarantee- The successful bidder shall submit PG as per procedure Mentioned in clause 5.1A of Northern Railway standard Tender Document 2022, The successful bidder shall submit the performance Guarantee(PG) amounting to 5% of the contract value
The tenderer shall submit along with the tender document, documents in support of his/their claim to fulfill the eligibility criteria as mentioned in the tender document. Each page of the copy of documents/certificates in support of credentials, submitted by the tenderer, shall be self-attested/digitally signed by the tenderer or authorized representative of the tendering firm. Self attestation shall include signature, stamp and date (on each page). Only those documents which are declared explicitly by the tenderer as "documents supporting the claim of qualifying the laid down eligibility criteria", will be considered for evaluating his/their tender
The Railway reserves the right to verify all statements, information and documents submitted by the bidder in his tender offer, and the bidder shall, when so required by the Railway, make available all such information, evidence and documents as may be necessary for such verification. Any such verification or lack of such verification, by the railway shall not relieve the bidder of its obligations or liabilities hereunder nor will it affect any rights of the railway there under.
Undertakings by Partnership Firm- In case the Letter of Acceptance (LOA) is issued to a partnership firm, the undertakings as per clause 18.10 of Annexure -VIII of Northern Railway Standard Tender Document 2022 shall be furnished by all the partners through a notarized affidavit, before signing of contract agreement.
As per Railway board letter No. 2018/CE-1/CT/4 dt. 17.10.2018 contractor shall mandatorily update the labour data on Railway Sharmik kalyan portal on monthly basis. The detailed guidelines are given in Clause 5.4 of PART-I of Standard Tender Document- 2022.
Interlocking of L.C. gates TUV>20000 in the section of ADSTE/MB of Moradabad Division.
SNTR1-SigLC-Interlocking~NR
SNTR1-SigLC-Interlocking
Open
Works - General
12 Months
Moradabad, Uttar Pradesh
₹0
₹15.9 L
8 Sept 2026
8 Sept 2026
16 Sept 2026
148 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 7,94,93,467.37 | ||
| — | 72000.00 | — | — | ||
| Excavating and refilling of trench in Normal Soil to the level of ground with rammed earth as per drg. No. (NR/S&T/CON/1. 1/97-A) so as not to form a drain 0.3 Mtrs. Wide & 1 Mtr. Deep on both side of the station alongside the track. It shall conform to the safe distance as per signalling and cable route plan in all type of soil, It also includes clearance of routes of trees & bushes. Inspection: Site Engineer, Specification as per part-lll of tender document. | — | — | — | 59,45,760 | |
| — | 5500.00 | — | — | ||
| Boring & Trenchless cabling along with supply& insertion of HDPE Self Lubricated pipes as per spec IS 4984 : 1995 with latest amendt material grade PE 63 110 mm dia with minimum 6mm wall thickness in the bore for laying of Signaling /Telecom /Power cable under track/road/culvert etc. cable laying covered separately. Inspection: Supply: RITES Installation: Site Engineer, Specification as per part-lll of tender document. | — | — | — | 82,46,920 | |
| — | 350000.00 | — | — | ||
| Laying of signalling/Telecom/power cables of different sizes as per drg. No. (NR/S&T/CON/1.1/97) and as per cable route plan approved by Railways and meggering of cable before and after its laying of all type of outdoor cables. Meggering to be done for each drum separately. Meggering sheets to be supplied and filled up by contractor and submitted to railways. Inspection: Site Engineer , Specification as per part-lll of tender document. | — | — | — | 26,07,500 | |
| — | 564800.00 | — | — | ||
| Supply and laying of 2nd class bricks in the trench and laying as per Drg. No. (NR/S&T/CON/1.1/97) as per instructions of the site Engineer. Inspection: Supply: Consignee Installation: Site Engineer, Specification as per part-lll of tender document. | — | — | — | 42,36,000 | |
| — | 40.00 | — | — | ||
| Supply of single app.case steel RE with 'E' type lock and key ward no.42 and handle as per drg. No. sketch no.RE/S&T/ALD/SK/219/82 and 221/82 with Alt.B.. Inspection: RITES , Specification as per part-lll of tender document. | — | — | — | 8,57,140 | |
| — | 40.00 | — | — | ||
| Casting, concreting and curing of foundation and erection of App. Cases (Single) as per drg. No. (NR/S&T/D&D/02/2024). All materials such as cement, sand, aggregate and anchor bolts shall be supplied by the contractor. App. Case single will be supplied by railway. Contractor is required to execute all type of repair works of foundations if required during inserting the cable for termination. Inspection: Site Engineer , Specification as per part-lll of tender document. | — | — | — | 1,89,469.6 | |
| for details. | Breakup | — | — | ||
| Preparation & fixing of bakelite hylum sheet 910x800x6 mm and bakelite shelf 900x450x25 mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts & bolts. Fixing of fuses, ARA terminal, plug in type Q series relays and other type relays on square bars fixing and jamming of cables with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the wood plank & all cable entry point on location boxes, location huts. JB's relay room/battery room to be closed with suitable masonry works covered with sand and plastering. Description for terminal drawing of circuits, inside app. Case. painting from outside as will inside with red oxide and aluminium paint is covered separately. Size of lettering will be 100 mm or as per instructions of Engineer at site. All material including bakelite shilf, hylum board, wood plank, angle iron square bar, wire and wiring material as per the IRS specn. nuts and bolts and other items shall be supplied by the contractor . Relays. ARA terminals & fuse only shall be supplied by the railway. | — | — | — | 2,11,206.7 | |
| — | 70.00 | — | — | ||
| Supply of Half app.case steel RE with 'E' type lock and key ward no.42 and handle as per drg. No. sketch no. RE/S&T/ALD/SK/220/82 and 221/82 with Alt.B.. Inspection: RITES , Specification as per part-lll of tender document. | — | — | — | 10,30,890 | |
| — | 70.00 | — | — | ||
| Casting, concreting and curing of foundation and erection of app. cases (Half) as per drg. No.(NR/S&T/CON/2.8/97) All materials such as cement, sand, aggregate and anchor bolts shall be supplied by the contractor. App case Half will be supplied by railway. Contractor is required to execute all type of repair works of foundations if required during inserting the cable for termination. Inspection: Site Engineer , Specification as per part-lll of tender document. | — | — | — | 2,85,525.1 | |
| for details. | Breakup | — | — | ||
| Provision, preparation & fixing of Bakelite hylum sheet 450 x 600 x 6 mm. Hylum board shall be fixed on angle iron frame of 25 mm x 25 mm x 3 mm. Angle iron frame will be fixed in location box secured by nuts & bolts. This includes fixing of fuses, ARA terminals fixing & jamming of cable with 2 inches salwood plank provided at the bottom. i) This includes opening, passing & jamming armour of each cable in the hole drilled separately for each cable through salwood plank & all cable entering points on location boxes, location huts, JBs, relay room/battery room to be closed with suitable masonry works covered with sand and plastering, wiring description of terminals, drawing of circuits inside app. case. Painting from inside as well as outside with red oxide & Aluminum paint is covered separately. Size of lettering to be 100 mm & as per the engineer's instruction. All materials such as teakwood shelf, hylum board, salwood plank, angle iron, square bar, NDT/HRC fuse bases, nuts & bolts etc. shall be supplied by the contractor. ARA terminal will be supplied by the Railway. Inspection: Site Engineer , Specification as per part-lll of tender document. | — | — | — | 2,75,438.7 | |
| — | 45000.00 | — | — | ||
| Termination of all the cores of all type of outdoor cable after its laying on both end. This also includes preparation of test report for core to core & core to earth on prescribed Performa for each core of the cable separately. This also includes dressing & lacing of cables on both ends. Performa for testing & material for lacing to be supplied by the contractor. Inspection: Site Engineer , Specification as per part-lll of tender document. | — | — | — | 5,40,900 | |
| — | 360.00 | — | — | ||
| Supply burying of earth electrodes pipe of 3 metre length and 50 mm dia. pointed on lower end by tapering for a length of 150mm as per drg. No. NR / S&T /CON / 6.3 / 97 and connecting with lightening arrester or signalling gears as per std. practices. The item includes digging of pit in earth 3 Mtrs. deep and fixing earth electrode pipe in it. Earth pipe shall be buried in the ground to the length of 2.7 Mtr after welding 6 SWG wire at the lower end and fixing through nut and bolt at the top. This includes casting of cement concrete enclosures as per drg. No. NR/S&T/CON/6.4/97. The enclosure is to be plaster on all sides with cement & sand mixture of 1:4 ratio. The soil treatment shall be done as per standard practices. The item includes provision of earthing lead. Inspection: Supply: RITES, Installation: Site Engineer , Specification as per part-lll of tender document. | — | — | — | 9,35,816.4 | |
| — | 20.00 | — | — | ||
| Supply of Electrically Operated Lifting Barrier Assembly Complete with drive mechanism, motor etc. with push button type control panel, boom locking arrangement, crank handle complete as per RDSO specification No.RDSO/SPN/208/ 2012 Ver. 2.0 or Latest. Both the Booms Shall be as per RDSO Drg.No.RDSO/ S11600 of GI Boom in Octagonal shape with tempering cross section with telescope structure. The total length of the Boom shall be 9.76m (Maximum 4 sections joined by nut and bolts). Operating voltage of the gate should be 110 V AC. Tool kit consisting of standard size of wrench/spanner and Allen Keys should also be Supplied with each set (02nos) of ELB. Note: Drg.No, RDSO/S-11600 inclusive of 2 stop boards, boom light boxes, MS counter weights, 2 Nos. boom support for resting boom, boom locking assembly, control panel. Inspection: RDSO , Specification as per part-lll of tender document. | — | — | — | 63,81,336.2 | |
| — | 18.00 | — | — | ||
| Installation wiring & commissioning of electrically operated lifting barrier as per standard practice Inspection: Site Engineer, (Pre-commissioning Checklist by OEM), Specification as per part-lll of tender document. | — | — | — | 9,89,450.28 | |
| — | 36.00 | — | — | ||
| Supply of Lifting barrier booms of 32 fit suitable for electric lifting barrier gates from RDSO approved firm as per RDSO specifications RDSO/SPN/208/2012Ver.2 or latest Inspection: Consignee , Specification as per part-lll of tender document. | — | — | — | 3,70,006.92 | |
| — | 18.00 | — | — | ||
| "Supply, Installation & Commissioning of Emergency Sliding Boom complete with all accessories for L/B gate." Inspection: Supply: RITES, Installation: Site Engineer, Specification as per part-lll of tender document. | — | — | — | 52,46,568.72 | |
| — | 36.00 | — | — | ||
| Supply of Key lock relay (KLCR), type TMA 24V DC with 2F/2B contacts configuration with different wards combination, details of ward combination will be provided during execution of work. Inspection: RDSO , Specification as per part-lll of tender document. | — | — | — | 2,98,059.84 | |
| — | 36.00 | — | — | ||
| Fixing and wiring complete KLCR and its box in location boxes, supply, installation, wiring of heavy duty push button, LED indicator on MS sheet as per N.R. practice for crank handle locking. This work includes fixing & wiring of magneto telephones as per instructions of the site Engr. This includes all materials such as heavy duty push button, LED indicator (10mm), MS sheet of 4.5mm thick, nuts and bolts, fixing materials for the magneto telephone, and wiring materials to be supplied by contractor. Inspection: Site Engineer, Specification as per part-lll of tender document. | — | — | — | 3,79,619.28 | |
| — | 2700.00 | — | — | ||
| Reflective Tape Yellow:- Highlighter grade retro reflective tape is made of non- metalized polycarbonate micro prismatic visible from 1000 meters highly durable ASI 90 specified reflection value will not deteriorate as sure clean application and endures protection against seepage and dirt are to confirm compliance to ASI 90 size per four feet width in roll. Inspection: Consignee , Specification as per part-lll of tender document. | — | — | — | 3,55,482 | |
| — | 52.00 | — | — | ||
| Supply of 2 Aspect colour light signal unit complete without holders, lamps, lenses and signals transformers, as per RDSO Drg. No. SA-23003 A/M (Adv), Alt-9 or latest, spec.IRS-S- 26/64, Rev.1 or latest. Inspection: RDSO , Specification as per part-lll of tender document. | — | — | — | 9,50,558.44 | |
| — | 58.00 | — | — | ||
| Supply of 3/4 Aspect colour light signal unit complete without holders, lamps, lenses and signals transformers, as per RDSO Drg. No. SA-23002 A/M (Adv), Alt.-9 or atest,SA- 23001 A/M (Adv), Alt.-9 or latest respectively, spec. IRSS- 26/64 or latest. Inspection: RDSO , Specification as per part-lll of tender document. | — | — | — | 12,81,362.68 | |
| for details. | Breakup | — | — | ||
| Supply of colour light signal post with ladder & bases as per tech. spec. IRS-S-6-81 or latest of the following size :- Inspection: RITES , Specification as per part-lll of tender document. | — | — | — | 21,83,697.56 | |
| — | 110.00 | — | — | ||
| Casting, concreting & curing of foundation of main signal as per Drg. No. (NR/S&T/Con/2.1/97). All material such as cement, sand, aggregate & anchor bolts shall be supplied by the contractor. Inspection: Site Engineer, Specification as per part-lll of tender document. | — | — | — | 10,17,321.8 | |
| for details. | Breakup | — | — | ||
| "Fixing of CLS surface base, bolting on the foundation. Erection of CLS post with signal unit on the top or on an offset bracket and fitting ladder and guard to the post at the top Concreting ladder base and embedded into the ground with supporting bracket in the middle. Blanking of the ladder for a distance of 1 feet between the height 6'9""and 7'9""from the rail level by MS angle and MS sheet 0.6mm thick wherever required. (i) This includes provision of wooden ( sal ) cross arm 1Mx1M for CLS unit prior to the commissioning, fixing of AC / DC lit LED Signal unit and hood on CLS unit, wiring the CLS unit and fixing the signal. Elevation and distance of foundation from track shall be in accordance with schedule of dimension for Indian ailway published by Government of India & approved Drawings. All items for the above work except items mentioned in Annx B-2 shall be supplied by the contractor including following items (ii) U bolt for offset bracket. (iii) Wooden cross arm 1Mx1M (iv) MS sheet and MS angle for blanking of ladder (v) Wire mesh guard, U-lock for unit , nuts and bolts etc for the following." Inspection: Site Engineer, Specification as per part-lll of tender document. | — | — | — | 3,61,819.9 | |
| — | 30.00 | — | — | ||
| Supply of Electronic Timer relay, 24 V DC @ 40<47@ 120 sec ) as per RDSO Spec. IRS:S 61/2000 (Amend. No. 3) or latest. Inspection: RDSO , Specification as per part-lll of tender document. | — | — | — | 1,06,456.5 | |
| — | 18.00 | — | — | ||
| Dismantling of lifting barrier/gate leaves/ELB complete set along with winch, wire rope, boom locking arrangements. All dismantled material to be transported and stacked in the store of SSE/Sig of MB div. Inspection: Site Engineer, Specification as per part-lll of tender document. | — | — | — | 55,981.98 | |
| — | 40.00 | — | — | ||
| Painting of two coats of Enamel paint over one coat of Red Oxide primer after scrapping and cleaning of the surface. Paint to be of reputed make Asian/Dulux/Berger or similar. App. Cases inside and outside to be done by Silver colour. (Apparatus Case Full) Inspection: Supply: Consignee, Painting: Site Engineer, Specification as per part-lll of tender document. | — | — | — | 22,617.6 | |
| — | 70.00 | — | — | ||
| Painting of two coats of Enamel paint over one coat of Red Oxide primer after scrapping and cleaning of the surface. Paint to be of reputed make Asian/Dulux/Berger or similar. App. Cases inside and outside to be done by Silver colour. (Apparatus Case Half) Inspection: Supply: Consignee, Painting: Site Engineer, Specification as per part-lll of tender document. | — | — | — | 35,995.4 | |
| — | 110.00 | — | — | ||
| Painting of two coats of Enamel paint over one coat of Red Oxide primer after scrapping and cleaning of the surface. Paint to be of reputed make Asian/Dulux/Berger or similar. (Main Signal post, base, unit and complete fittings) Inspection: Supply: Consignee, Painting: Site Engineer, Specification as per part-lll of tender document. | — | — | — | 82,898.2 | |
| — | 1000.00 | — | — | ||
| Supply and Fixing of GI. Pipe 75 mm dia, 3mm thick perforated at a distance of 20 CM or lesser of required length at culverts/bridges/along the cutting suitably concreted at both ends as per drg. No(NR/S&T/CON/1.4/97) or at ASM office/other buildings suitably fixing it to the wall and at both ends G.I. Clamp of M.S. Flats bolts and nuts, to be supplied by the contractor. Inspection: Supply: RITES, Installation: Site Engineer, Specification as per part-lll of tender document. | — | — | — | 7,73,390 | |
| — | 1000.00 | — | — | ||
| Wiring of relays in relay room/relay huts as per approved wiring diagrams. All material required will be supplied by contractor including indoor cables and wires of 1x1, 1x0.6, 3/.029, 16/0.2, 40x0.6, 40x1, 60x0.6, 60x1 dia, of copper conductor as per NR practice conforming to latest IRS S-76/89 (Amd.3) or latest available specifications. This also includes soldering, dressing, bunching, lacing, fixing of relay bases etc. and provision of LED indication box of vital relays in relay room if required and provision of potential free contacts of all relays on tag block for data logger as per instruction of site Engineer. Indoor cable/wire shall be as per Spec. No. IRS-S 76/89 (Amd.3) or latest available. Inspection: Site Engineer, Specification as per part-lll of tender document. | — | — | — | 4,81,370 | |
| — | 36.00 | — | — | ||
| Supply of magneto telephone with all accessories as per IRS-TC-36/97 (Amd 2) or latest. Inspection: Consignee , Specification as per part-lll of tender document. | — | — | — | 1,75,248.36 | |
| — | 36.00 | — | — | ||
| "Fixing & wiring of magneto telephones with all accessories including Standard battery box and 3 nos. Of RR cells in the ASM office with crank handle locations/ K-points and interlocked L-xing gates as per instructions of the site Engr. All fixing materials including Standard battery box and 3 nos. Of RR cells to be supplied by the contractor. Inspection: Site Engineer, Specification as per part-lll of tender document. | — | — | — | 21,452.4 | |
| — | 15.00 | — | — | ||
| Supply & Installation of control cum Indication panel for L.C. gate. Inspection: Supply- Consignee, Installation: Site Engineer. Specification as per part-lll of tender document. | — | — | — | 10,91,148.75 | |
| — | 25.00 | — | — | ||
| "Fabrication, supply and fixing of relay racks of size 2200mmx690mm (as per Drg. No. NR/S&T/CON/4.3/97A made of angle iron size 45mmx45mmx6mm along with outer frame made of angle iron size 65mmx65mmx8mm, fitted with M.S. squares bars duly ionized, descriptions strips to accommodate Plug-in-type relays/groups/Point contractor units/ECRs/HMUs. All fixing material like antilting device, hylum sheets if required, bolts & nuts, washers, insulators, shoe, angle irons, flats, L-bolts, Catenary wires and cement concrete etc. will be supplied by the contractor. This includes cleaning, priming by red oxide, painting & description etc. with ISI mark paints. Inspection: Supply: Consignee, Painting: Site Engineer, Specification as per part-lll of tender document. | — | — | — | 4,86,135 | |
| — | 27.00 | — | — | ||
| Fabrication, supply and fixing of cable termination board of size 2200mmx900mm as per Drg. No. NR/S&T/CON/4.1/97A made of angel iron size 45mmx45mmx6mm along with outer frame made of angle iron size 65mmx65mmx8mm duly fitted with Bakelite sheet (HYLAM MAKE or similar) of size 6mm thick. This also includes fixing of ARA terminals/strips/Wago connectors & fuse bases etc. Supply and fixing of hard wood of size 70cmx25cmx4cm in the back at bottom for jamming of armour of cables, each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry works covered with sand and plastering. All the fixing materials like bolts, nuts, washers, Insulators, shoe, angle irons, flats, L- bolts, Catenary wires & cement concretes etc. will be supplied by the contractor. This includes cleaning, priming by red oxide, painting & description etc. with ISI mark paints. Inspection: Supply: Consignee, Painting: Site Engineer, Specification as per part-lll of tender document. | — | — | — | 5,70,775.68 | |
| — | 50000.00 | — | — | ||
| Loading, leading & unloading of released material from site to the AMV store at Lucknow or to any other store of Moradabad Division by contractor. Loading, leading & unloading of material, to be supplied by railway from a store located more than 100 Km from the concerned consignee of the work. Inspection: Consignee , Specification as per part-lll of tender document. | — | — | — | 3,75,500 | |
| — | 15.00 | — | — | ||
| Fabrication, supply, installation and wiring of power supply board in IPS room/ relay hut/ relay room as per drawing no. SSTE/PS/1237 dt. 26.02.92 and extension of the power supplies from IPS to power supply board and from power supply board upto the MDF board. This includes fixing of ARA terminals, fuse bases, switches etc. and termination of power wire/ cables. This includes supply of all wiring & termination materials except terminals & fuses, power & U/G cable/wires. Wherever outdoor U/G cables are to be laid that is covered separately. Inspection: Supply: Consignee, Installation: Site Engineer, Specification as per part-lll of tender document. | — | — | — | 2,48,444.1 | |
| for details. | Breakup | — | — | ||
| Supply of power wires IS2465/1984 & IS 694/1990 or latest & As per IRS Spec No. 76/89(Amd.3) or latest of the following sizes :- Inspection: RDSO , Specification as per part-lll of tender document. | — | — | — | 9,58,096.53 | |
| — | 1000.00 | — | — | ||
| Supply of electric fuse complete with fuse block(base) for Railway signalling non- deteriorating type low voltage fuse assembly 2Amp/4Amp/16Amp. (As per requirement) to suit RDSO Specn. No.IRS: S-78/92 and fuse block made of PBT/Polycarbonate as per IRS: S-75/2006 (Rev- 2) and drg no. 23748 (Alt.4) or latest. Fuse block shall be suitable for round head type fuses. Inspection: RDSO , Specification as per part-lll of tender document. | — | — | — | 2,06,060 | |
| — | 18.00 | — | — | ||
| Supply, Installation, wiring, testing & commissioning of Micro Processor based Remote Terminal Unit (RTU) with 128 digital input & 16 analog input as per RDSO Spec. No. IRS (S) 99/2006 or latest. Inspection: Supply: RDSO Installation: Site Engineer (OEM PCCL) Specification as per part-lll of tender document. | — | — | — | 37,90,572.12 | |
| — | 18.00 | — | — | ||
| Supply, installation, configuration and testing of Adaptor PCB for connecting GSM/GPRS Modem to RTU Mother Board GSM / GPRS Modem and suitable software for GSM/GPRS based RTU as per technical specification. Inspection: Supply: Consignee, Installation: Site Engineer, Specification as per part-lll of tender document. | — | — | — | 1,34,260.74 | |
| — | 15.00 | — | — | ||
| Supply fixing and wiring of Fuse Auto Changeover System (FACS main system) as per RDSO/SPN/209/2012 Rev. 2.0 with latest amendments. One automatic changeover unit comprise 32 nos of external Non Deteriorating Type or 'G' type fuses of various Ampere Rating, working voltage- 24 VDC which are in signalling circuits. System shall have 8 cards with monitoring arrangement of 4 fuses in one card. Installation, wiring, Testing and commissioning of Fuse Alarm System, it consists of fixing of modules of fuse alarm system on existing relay rack, wiring from existing fuses to modules, soldering, lacing etc. working to be executed without affecting the functioning of the existing Circuits/Gears and the work shall be supplied by the contractor. Inspection: Supply: RDSO, Installation: Site Engineer, Specification as per part-lll of tender document. | — | — | — | 5,91,326.4 | |
| — | 15.00 | — | — | ||
| Supply & installation of Earth leakage detector for monitoring different AC and DC, supplies including all accessories as per RDSO specifications no RDSO/SPN/256/2025 Version : 2.0 or latest. (Eight channels). Inspection: Supply: RDSO, Installation: Site Engineer, OEM PCCL, Specification as per part-lll of tender document. | — | — | — | 15,37,963.5 | |
| — | 90.00 | — | — | ||
| Supply Installation and commissioning of maintenance free earthing system which consists of supply of earthing kit-1 set consisting of (1) Earth Electrodes of copper clad steel alloy of 10 feet (3mts) long, 17mm dia and copper thickness of 250 microns- 1Nos. (II) RDSO approved Earth enhancing compound in 30 kg. Pack - 01 Nos. (III) Copper tape of 25mm x 6mm x 300mm with 99% purity - 02 Nos. and another of 25 mm x 6mm x 150mm to terminate on earth electrode. (iv). This include supply of 35 Sq.mm/16 Sq. mm/10Sq.mm multistrand single core PVC insulated copper cable as per IS 694 for connecting main earth electrode to the equipment. The earthing material shall be supplied as per RDSO specification RDSO/SPN/197/2008 or latest. Inspection: Supply: RDSO Installation: Site Engineer (Installation to be done by OEM), Specification as per part-lll of tender document. | — | — | — | 15,16,161.6 | |
| — | 108.00 | — | — | ||
| Supply and fixing of P/G/C/IB marker with complete fitting as per Drg No NR/S&T/Con/6.2/97. All materials required for the job such as MS sheet, MS angle, nuts and bolts paints and painting material will be supplied by the contractor. Inspection: Supply: Consignee, Installation: Site Engineer, Specification as per part-lll of tender document. | — | — | — | 37,976.04 | |
| — | 108.00 | — | — | ||
| Supply of Signal No. Plates as per IRSEM Inspection:Consignee.Specification as per part-lll of tender document | — | — | — | 55,327.32 | |
| — | — | — | II; | ||
| — | 4.00 | — | — | ||
| "Testing & commissioning of PI/RRI (medium station) installation with MACLS system during pre NI (when some line is blocked / disconnected) and NI as a whole shall be carried out by the engineer incharge of the work with the help of representative of contractor for indoor and outdoor work. All artisan staff and labours required for testing and commissioning of PI work shall be provided by the contractor for indoor and outdoor work. Testing equipments such as multimeter/ track ckt. Equipments etc. shall be provided by the contractor for outdoor and indoor works at his own cost. Testing shall be carried out to ensure 13 the compliance of SEM, G&SR, block working manual and adherence to specifications of the tender. Inspection: Site Engineer, Specification as per part-lll of tender document | — | — | — | 1,26,187.48 | |
| — | 20.00 | — | — | ||
| Design and preparation of Selection Table, Panel Diagram, Wiring Diagrams and all other related documentation as per approved SIP for stations of Moradabad division on Northern Railway. Specification for PI/RRI/IBS work (Circuits shall be designed by the contractor with the use of Q-series relays to suit Railway electrified area & obtaining approval of the engineer as per following - (i) Supply of 6 copies of completion set of superior quality paper, laminated, properly bound in steel clip jaw file with cushioned cover.(ii) Software back up of complete set in the form of CDs.(ii) One complete set of tracings.(iv) Design through CAD(v) Drawings in A3 & plans in bigger size(six sets). Inspection: Site Engineer, Specification as per part-lll of tender document | — | — | — | 74,532.2 | |
| — | 16.00 | — | — | ||
| Supply, testing & installation of pre wired domino with indication LED/Lamp. For point, track circuits, signal indication & operation Inspection: Supply: Consignee, Installation: Site Engineer, Specification as per part-lll of tender document | — | — | — | 24,925.44 | |
| — | 3.00 | — | — | ||
| Redesign of EI system alterations as per approved signalling plan. This involves redesigning if EI system alteration as per approved signalling plan, supervision of installation for alterations, testing and commissioning. Design of Modification of the existing interface and interlocking ckts including design of the same is also covered under this schedule item. Modifications to the application logic software of VDU and MT are under scope of this item. Alteration to the relay racks wiring as per the approved interface ckts including supply of all necessary wiring material/racks at station. FAT and SAT are to be carried out as part of this schedule Item. Inspection: Site Engineer, (Any new card or module: RDSO), Specification as per part-lll of tender document | — | — | — | 77,37,191.73 | |
| — | 2000.00 | — | — | ||
| Supply and Placing of Trunking and Capping (RCC Duct) RCC of 500mm Width as per Drg. No. SDO/Cable laying/ 007(Annexure-10), as detailed in document No. RDSO/SI/G/2010 Ver.1.1 or latest on 'Guidelines on signalling cable laying' Inspection: RITES , Specification as per part-lll of tender document | — | — | — | 29,39,580 | |
| — | 18.00 | — | — | ||
| Design and preparation of wiring diagram for Level-Xing MACLS on the basis of approved interlocking plan, typical circuit diagram and as per Railway practice and latest rules prescribed by the Railway and obtaining approval of the competent authority. Preparation of locking tables and dog charts to suit colour light signalling plan and obtaining the approval of the competent authority. Drawing shall be supplied as per following: - (i) Supply of 6 copies of completion set of superior quality paper, laminated, properly bound in steel clip jaw file with cushioned cover.(ii) Software backup of complete set in the form of CDs.(iii) The complete set of tracings.(iv) Design through CAD.(v) Drawing in A3 & plans in bigger size (6 sets). Inspection: Consignee , Specification as per part-lll of tender document | — | — | — | 5,12,657.46 | |
| — | 18.00 | — | — | ||
| Preparation of cable route plan, Cable core chart, Power supply arrangement, circuit route termination chart, cable termination chart in relay room and location boxes, Location wiring plan, Cable insulation chart and register, Earth Resistance Chart, Track circuit test card, Signal Lamp/ LED Register, Battery History card, Fuse analysis chart, Equipment disposition plan, Polarity chart (Track insulation plan),Terminal and Contact analysis plans, and obtaining for Level -Xing gate MACLS. Drawing shall be supplied as per following :- (i) Supply of 6 copies of completion set of superior quality paper, laminated, properly bound in steel clip jaw file with cushioned cover. (ii)Software back up of complete set in the form of CDs. (iii) One complete set of tracings.(iv) Design through CAD (v) Drawings in A3 & plans in bigger size. (six sets). Unit Job per Level Crossing gate MACLS=Job Inspection: Consignee , Specification as per part-lll of tender document | — | — | — | 1,67,688.72 | |
| — | 36.00 | — | — | ||
| "Supply and Installation of 25 W gate hooter as per spec. no. SDH 25 reputed make and as per the Instruction of Railway representative at site. It should be fitted inside MS sheet box of min 20 gauge on suitable post." Inspection: Supply: Consignee, Installation: Site Engineer, Specification as per part-lll of tender document | — | — | — | 57,827.52 | |
| — | 22.00 | — | — | ||
| Supply and installation of goods warning board of as per SEM part -II para no. 12.134 warning board made out of 3mm thick aluminium sheet confirming to IS-736 with back support frame of 25x25x3mm angle iron. The tape should be:- Non metalized polycarbonate micro prismatic lenses and reflected light visible from more than 1 km. It should be pressure sensitive, Highly durable and non-corroding as well as high dispersion angle. Thickness of Highlighter Grade Retroreflective tapes shall be 0.35mm to 0.46mm. Inspection: Supply: Consignee, Installation: Site Engineer, Specification as per part-lll of tender document | — | — | — | 2,06,789.88 | |
| for details. | Breakup | — | — | ||
| Supply of disconnect terminal Wago or similar as per spec. no. RDSO/SPN/189/2004 Ver 3.0 or latest as below: Inspection: RDSO , Specification as per part-lll of tender document | — | — | — | 41,73,690 | |
| — | 5000.00 | — | — | ||
| Supply of Terminal Block 25MM centre M-6 terminal made of PBT to RDSO Drg.no.SA23471 A (Alt-4) or latest as per RDSO specn. IRS-S-75/2006 (Rev 2) or latest. Inspection: RDSO , Specification as per part-lll of tender document | — | — | — | 3,60,600 | |
| — | 900.00 | — | — | ||
| Fabrication, supply and fixing of cable marker of 1:3:6 concrete as per Drg.No.15-D1 (IRSEM Appendix II). The marker shall be fixed at various places of cable route as per instruction of Engg at site. Inspection: Site Engineer, Specification as per part-lll of tender document. | — | — | — | 1,81,998 | |
| — | 15.00 | — | — | ||
| "Installation & wiring of SMPS based Integrated Power Supply system for station as per. spec no. RDSO/SPN/165/2012 (Ver.3) or latest as per guide lines. All materials for installation shall be supplied by contractor. Transportation of IPS from Railway store to site shall be done by contractor. Power supply (DG set with fuel) for charging of Batteries shall be arranged by contractor. Charging of batteries, testing & commissioning as pre commissioning check list shall be done by OEM. Fabrication, Supply, installation and wiring of Power Supply Board for IPS Room/ Relay Hut/ Relay Room as per approved drg. SSTE/PS/1237 Dt. 26.02.92 and extension of the power supplies from IPS to power supply board and power supply board up to MDF board. This includes fixing of ARA terminal, fuses, wire cable, switches. Wherever outdoor U/G cable is to be laid, same shall be covered separately" Inspection: Site Engineer, OEM PCCL, Specification as per part-lll of tender document | — | — | — | 9,35,479.5 | |
| — | 15.00 | — | — | ||
| "Supply of single spike air terminals of 17.2 mm dia. & 2000 mm length as required and as per site conditions. The air terminal shall be manufactured with Copper Bonded Steel & shall be as per IEC 62561-2. The air terminal shall be fixed with concrete base arrangement. Inspection: RDSO , Specification as per part-lll of tender document | — | — | — | 75,000 | |
| — | 420.00 | — | — | ||
| Down Conductor. (i)Supply of 8 mm dia Copper Bonded Steel round conductor (250Micron) for Down conductors to be installed on vertical wall, facade of masonry / glass /metallic work. It shall meet the requirements of IEC 62561-2. Inspection: RDSO , Specification as per part-lll of tender document. | — | — | — | 1,41,750 | |
| — | 300.00 | — | — | ||
| "Supply of Down Conductor holder for holding of 8 mm dia. round conductor (for RCC wall). The conductor holder shall be of Stainless steel which is mounted on plastic base support and shall meet the requirements of IEC 62561-4.It should be installed at every 1 mtr. Inspection: RDSO , Specification as per part-lll of tender document | — | — | — | 90,000 | |
| — | 30.00 | — | — | ||
| Supply of Test Clamp to disconnect the down conductor from the earth termination network for regular checks of the earth termination resistance value which shall be of Stainless steel and suitable for connecting 8 mm aluminium round conductor to 25x2mm Copper conductor (with enclosure). It shall meet the requirements of IEC 62561-2. Inspection: RDSO , Specification as per part-lll of tender document | — | — | — | 60,000 | |
| — | 15.00 | — | — | ||
| Supply of Digital Lightning Strike counter Model: JMV/DLSC-3D or better for counting the number of lightning strikes and has a 3 Digit display facility and also records date and time. The Counter should be mounted on the Down Conductor. The Lightning Counter should be IP 67 rated enclosure suitable for external application. It shall meet the requirements of IEC 62561-6 Inspection: RDSO , Specification as per part-lll of tender document. | — | — | — | 2,25,000 | |
| — | 60.00 | — | — | ||
| Supply installation of 2DT Exothermic joint Between 25 x 2mm Horizontally laid Copper Strip to 25 x 2mm Horizontally laid Copper Strip with UL Tested. Inspection: Supply: Consignee, Installation: Site Engineer, Specification as per part-lll of tender document | — | — | — | 42,000 | |
| — | 15.00 | — | — | ||
| "Supply & Installation of Isolating spark Gap for lightning equipotential bonding of different earth grids according to IEC 62561 part-3 at 100kA impulse current, IP 68, fire retardant enclosure." Inspection: Supply: RDSO, Installation: Site Engineer, Specification as per part-lll of tender document | — | — | — | 3,22,500 | |
| — | 15.00 | — | — | ||
| Installation of Class A device on the top of the building. The device shall be installed at a height of about 3 mtrs. from the roof of the building using a GI mast. The device shall be connected to the Earth pit using the down conductor or similar. This down conductor shall be run firmly along the side of the mast with the help of the spacers. It shall also be ensured that this down conductor shall not touch the building throughout. The down conductor shall be connected to the earth Electrode using Exothermic Welding. A counter shall be installed at an appropriate place to count the number of occurrences. All the accessories like spacers, welding materials etc. required for the installation shall be arranged by the contractor only Inspection: Site Engineer, Specification as per part-lll of tender document. | — | — | — | 1,59,078.6 | |
| — | 200.00 | — | — | ||
| Supply of DC neutral line relay QNA1K (QSA3), AC immune, DC neutral line 24V, 12F/4B contacts, complete with plug board, retaining clip and connectors, Conforming to BRS 930A, (as applicable) IRS:S34 & IRS:S23 or latest, Inspection: RDSO, Specification as per part-lll of tender document | — | — | — | 12,69,512 | |
| — | 50.00 | — | — | ||
| Fabrication, supply and fixing of scaffolding / cable careers made of angle iron size (35mmx35mmx5mm) and flat of size (25mmx3mm) as per the instructions of engineer at site. The space between two flats will be 25cm or less as per the site requirements. All the fixing materials i.e. bolts, nuts, washers, insulators, cement, concrete etc. will be supplied by the contractor. This includes cleaning, priming by red oxide, painting with ISI mark paints. Inspection: Site Engineer. Specification as per part-lll of tender document | — | — | — | 25,353 | |
| — | 30000.00 | — | — | ||
| Re-lettering (Each of 1 cm height) with synthetic Enamel paint (one coat) on location boxes or places advised by site engineer.Specification as per part-lll of tender document | — | — | — | 37,500 | |
| — | 750.00 | — | — | ||
| Supply of 25mm x 2 mm bare copper strips in the equipment room. Specification as per part-lll of tender document | — | — | — | 9,44,812.5 | |
| — | 750.00 | — | — | ||
| Routing and termination of 25x2mm Copper tape/8 mm solidcopper round conductor which isto be fixed inside the equipmentroom with 60mm, 6KVA insulationstuds including supply ofinsulation studs. The separation ofthe two successive insulation studshould be 600mm apart. Specification as per part-lll of tender document | — | — | — | 68,805 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
interlocking1_compressed.pdf Tender document
ATTACHMENT
interlocking1_compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .