Loading…
Loading…
Tender Value
₹10.7 Cr
EMD Value
₹5 L
Closing Date
8 May 2026, 5:00 pmClosed
Similar tender results from the same govt authority in the past 3 years.
MR Ahammad Danish
CE(Raipur)
Widening & Strengthening of Raykheda - Murra - Math – Kharora Road, Length-14.125 K.M. i/c. Culverts at Distt. Raipur(Vidhansabha dn. Raipur).
189079
NIT NO: 058/TC/2026-27
RESTRICTED TENDER
WORKS
11 days
CE(Raipur)
Required Past Technical Experience: AS PER NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
17 documents required · 17 mandatory
Public Works Department (PWD)
WORKS
MR Ahammad Danish
RESTRICTED TENDER
PERCENTAGE
A
CE(Raipur)
PWD Circle-1,Raipur
Vidhansabha Div Raipur
120
11
No
0
189079
8 May, 2026 5:00:00 PM IST
13 May, 2026 10:00:00 AM IST
17 Apr, 2026 7:00:00 PM IST
NIT NO: 058/TC/2026-27
Widening & Strengthening of Raykheda - Murra - Math – Kharora Road, Length-14.125 K.M. i/c. Culverts at Distt. Raipur(Vidhansabha dn. Raipur).
500000.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
106535000.00
2
12 May, 2026 5:00:00 PM IST
106535000
AS PER NIT
AS PER NIT
AS PER NIT
0.00 INR
21d 3h 38m
17 documents required · 11 mandatory · 6 optional
₹0
₹5 L
16 Apr 2025
16 Apr 2025
13 May 2026
17 Apr 2026
8 May 2026
17 Apr 2026
12 May 2026
Clearing and grubbing Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 meters including removal and disposal of top organic soil not exceeding 150 mm in thickness if required and as per relevant clauses of section-200. In area of light jungle
Dismantling of flexible pavements and disposal of dismantled materials up to a lead of 1000 meters, stacking serviceable and unserviceable materials separately and as per relevant clauses of section-200. Bituminous courses
Compacting Original Ground Compacting Original Ground supporting embankment Loosening, leveling and compacting original ground to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at O.M.C. and then compacted by rolling so as to achieve minimum dry density as given in table 300-2 for embankment construction.
Granular Sub-base as per Table:- 400-1 Construction of granular sub-base by providing graded Material, , carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface watering, rolling and compacting with vibratory power roller at OMC to achieve the desired density, complete as per clause 401. Plant mix method (with Mechanically crushed stone only) For Sub-base cum drainage layer or upper sub-base with Grading-VI Material
Prime coat (Providing and applying primer coat with oil based bitumen emulsion (SS-1, grade confirming to IS:8887) on prepared surface of granular Base including clearing of road surface and spraying primer using mechanical means as per clause 502. on WBM/WMM surface @0.85 Kg/sqm.
Tack coat Providing and applying tack coat with bitumen emulsion (RS-1, grade confirming to IS:8887) using emulsion pressure distributor on the prepared bituminous/granular surface cleaned with mechanical broom and as per clause 503. Granular surfaces treated with primes @ 0.30 kg /Sqm.
Bituminous surfaces @ 0.25 kg /Sqm
Cement Concrete Pavement @ 0.35 kg /Sqm
Dense Bituminous Macadam (Providing and laying dense bituminous macadam with minimum 40-60 TPH capacity HMP using crushed aggregates of specified grading, premixed with bituminous binder @ 4.0 to 4.5% by weight of total mix of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No.505 complete in all respects.) With mechanical paver finisher for Grading-II(26.5 mm nominal size bitumen content 4.50%)
Bituminous Concrete (Providing and laying bituminous concrete with minimum 40-60 TPH capacity hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder @ 5.0 to 6.0% by weight of total mix of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects) With mechanical paver finisher for Grading II (13.2 mm nominal size) with bitumen 6.0 %.
Providing and laying cement concrete for plain concrete/ reinforced concrete i/c form work, shuttering complete in as per drawings and specifications.( For Village roads) P.C.C. M-15
Construction of RCC open drain Construction of RCC open drain 0.60m x 0.60m inside dimension lined with 120 mm thick RCC M-20 walls, 120 mm thick CC M-20 foundation, over 100 mm thick (Av) leveling course in PCC M-15 including excavation , dressing of sides and bottom, provision of HYSD reinforcement consisting 8 mm dia horizontal bars @ 150 mm c/c and L-shaped 8 mm dia vertical bars @ 150 mm c/c (L= 800 mm) including cutting , bending and binding wire, placing in position , providing shuttering and concreting by using concrete mixer, compaction by vibration etc complete as per drawings and technical specifications.
Construction of RCC Drain/Cover/ Chamber Construction of RCC drain/chamber cover, placing in position, providing shuttering and concreting by using concrete mixer, compaction by vibration etc complete as per drawings and technical specifications excluding reinforcement. with RCC M-20
Supplying, Fitting and Placing un-coated HYSD bar Reinforcement in drain/cover/chamber complete as per Drawing and Technical Specifications.
Kilo Meter Stone (Reinforced cement concrete M15grade kilometer stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc) 5th Kilometer Stone (precast)
Ordinary Kilometer Stone (precast)
Hectometer Stone (precast)
Retro- reflectrorized Traffic signs (Providing and fixing of retro- reflectrorized cautionary, mandatory and informatory sign as per IRC:67-2012 made of rectro reflective type sheeting vide clause 801.3, fixed over aluminum sheeting of rfequired thickness supported on a mild steel frame of ISA 40 x 40 x 5 mm and mild steel angle iron post 75 mm x75 mm x 6mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45cm x 60cm, 60 cm below ground level as per approved drawing and painting all components of the Sings and supports as per clause 7.2 of IRC: 67 - 2012 ) B) Made of Class - B High Intensity Micro Prismatic Grade Sheeting of Type IV ( for MDR) With Aluminum Sheeting of 2 mm thickness 900 mm equilateral triangle
900 mm high octagon
With Aluminum Sheeting of 1.5 mm thickness 600 mm circular
600 mm x 500 mm rectangular
Overhead Signs (Providing and erecting overhead signs with a corrosion resistant aluminum alloy sheet reflectorized with high intensity retro-reflective sheeting of Micro prismatic grade type with vertical and lateral clearance given in clause 802.2 and 802.3 and installed as per clause 802.6 over a designed support system of aluminum alloy or galvanized steel trestles and trusses of sections and type as per structural design requirements and approved plans) Truss and Vertical Support
Aluminum alloy plate for over head sign
meter
Road Marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface (Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35-1997. The finished surface to be level, uniform and free from streaks and holes.)
Providing and laying Reinforced Cement Concrete pipe NP 3 / prestressed concrete pipe on first class bedding. (Laying Reinforced cement concrete pipe NP3 /prestressed concrete pipe for culverts on first class bedding of granular material including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets). 600 mm dia
Providing and laying of a reinforced cement concrete pipe duct, 300 mm dia., across the road ( new construction ) , extending from drain to drain in cuts and toe of slopes to toe of slopes in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipes as per IRC: 98-2011, bedded on a 0.3 m thick layer of granular material free of rock pieces , outer to outer distance of pipes at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts , joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC:98-2011 and approved drawings. Single row for one utility service
Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification including trimming of slopes to proper profile and preparation of bed and as per clause 2504.
meter
Providing and laying Reinforced Cement Concrete pipe NP 3 / prestressed concrete pipe. (Laying Reinforced cement concrete pipe NP3 /prestressed concrete pipe for culverts including fixing collar with cement mortar 1:2 but excluding bedding below pipes, excavation, protection works, backfilling, concrete and masonry works in head walls and parapets . ) 1000 mm dia.
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification 710.1.4 of I.R.C. 78 and 2200. Granular material
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.) Ordinary soil Up to 3 m depth
Sand Filling in Foundation Trenches as per Drawing & Technical Specifications.
Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications. Using concrete mixer PCC Grade M15
PCC Grade M20
Providing and laying Plain / Reinforced cement concrete in sub-structure complete as per drawing and technical specifications section 1500, 1700 and 2200 (Newly laid concrete shall be covered by gunny bags). Height upto 5m Using concrete Mixer P.C.C. Grade M-20
Height upto 5m Using concrete Mixer RCC Grade M20
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification sections 1500, 1600 and 1700 (Newly laid concrete shall be covered by gunny bags). RCC Grade M 30 For Solid Slab Super Structure Using Concrete Mixer Height upto 5m
Filler joint Providing & fixing 20 mm thick compressible fiber board (12 m long x 25 cm deep ) in expansion joint complete as per drawing & Technical Specification.
meter
UOM Name
Percentage
Per mile
Siemens Per meter
Activity unit
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 1.08 MB
3662590503382863201_153213_1258250143523725404_129113_Guidelines_to_Bidders_EPS_v1.pdf
NIT • 0.13 MB
7259874129919866650_189079_FORM A.doc
NIT • 0.15 MB
680115740503134072_189079_NIT.doc
NIT • 0.31 MB
1789249100819411152_189079_189079 Notice.docx
NIT • 0.06 MB
9150978292926074276_189079_PQ.doc
NIT • 0.28 MB
4896976852728271393_189079_BOQ.xls
BOQ • 0.17 MB
Download all tender documents and submit your bid