| 1 | L1₹7.3 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹8.9 L+₹1.6 L (21.1%)Rejected-Finance 33 RUSHIKESH INGOLE NAGAR MODERN CO OPERATIVE HOUSING SOCIETY WARDHA ROAD NAGPUR MS 440 005 | NAGPUR | NAGPUR | MAHARASHTRA | 440005 | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹9.4 L+₹2.1 L (28.6%)Rejected-Finance 2 3 AMIT VIJAY APARTMENT KASTURBA CROSS ROAD KANDIVALI W MUMBAI 67 | MUMBAI | MUMBAI | MAHARASHTRA | 400067 | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹9.8 L+₹2.5 L (33.3%)Rejected-Finance B 10 KRISHNA IND ESTATE BIDC GORWA VADODARA 390016 | VADODARA | VADODARA | GUJARAT | 390016 | L4 | Rejected-Finance Not lowest |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
2 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER DAMAN
GARRISON ENGINEER DAMAN TAT RAKSHAK VIHAR DALWADA NANI DAMAN POST DAMAN (UT) PIN396210
STRUCTURAL AUDITING OF VARIOUS MARRIED ACCOMMODATION BUILDING P 61 P 62 P 63 P 64 P 65 AND P 66 AT ICGAS DAMAN
2023_MES_611327_1
8703/E8
Open Tender
Civil Works
Item Rate
120 days
DAMAN
AS PER NIT
9 documents required · 9 mandatory
₹500
GARRISON ENGINEER DAMAN
₹20,000
27 Sept 2023
31 Jul 2023
4 Sept 2023
31 Jul 2023
2 Sept 2023
14 Aug 2023
Amount
Structural auditing of building No P-61(Single Storey) in TRV Area at ICGAS Daman by visual inspection with photography and conducting adequate/required number of ND Tests and preparation and submission of ND test reports comprising the followings:- (a) Site visit, preparation and submission of detailed visual inspection and photography of buildings complete all specified and directed by Engineer-in-Charge. (b) Conducting adequate/required number ND Tests to be conducted by NABL accredited lab including rebound hammer test, Ultra sonic pulse Velocity Test (UPV test), Half-cell protentiometer test (HCP) and Carbonation test, Ultra thickness test, Core test and Compression test, Cover meter test, Chloride Profile test, for steel truss member and magnetic particle inspection for welds to defect surface and sub-surface discontinuity in welds and all other tests which is required for ascertaing the stability of structure, etc. (c) Providing of detailed report and recommendation including remedles for structural improvement/recommendation for further use of buildings or repair works to be carried out duly vetted by IIT/Govt Engineering college. (d) Submission Estimate, suggested repair/remedial measure and product specification of any other special items of material (alongwith manufacturer literature of special item of materials) to be incorporated for repairs. (e) Submission of details repairs for preparation of BOQ alongwith 06 sets of drawings(Hard and soft copy) indicating proposed addition/alteration/repairs. (f) Submission of any other details/documents, as required at the opinion of consultant. (g) Structural Engineer will visit the site during currency of repair work and after the repair work. He will also give the stability certificate of the structure. Note :- The cost of labour, transportation of T&P, scaffolding and making good the disturbed surfaces of structure and all equipment required for testing from point to point are deemed to be included in quoted rate.
Structural auditing of building Nos P-62(G+3) in TRV Area at ICGAS Daman by visual inspection with photography and conducting adequate/required number of ND Tests and preparation and submission of ND test reports comprising the followings:- (a) Site visit, preparation and submission of detailed visual inspection and photography of buildings complete all specified and directed by Engineer-in-Charge. (b) Conducting adequate/required number ND Tests to be conducted by NABL accredited lab including rebound hammer test, Ultra sonic pulse Velocity Test (UPV test), Half-cell protentiometer test (HCP) and Carbonation test, Ultra thickness test, Core test and Compression test, Cover meter test, Chloride Profile test, for steel truss member and magnetic particle inspection for welds to defect surface and sub-surface discontinuity in welds and all other tests which is required for ascertaing the stability of structure, etc. (c) Providing of detailed report and recommendation including remedles for structural improvement/recommendation for further use of buildings or repair works to be carried out duly vetted by IIT/Govt Engineering college. (d) Submission Estimate, suggested repair/remedial measure and product specification of any other special items of material (alongwith manufacturer literature of special item of materials) to be incorporated for repairs. (e) Submission of details repairs for preparation of BOQ alongwith 06 sets of drawings(Hard and soft copy) indicating proposed addition/alteration/repairs. (f) Submission of any other details/documents, as required at the opinion of consultant. (g) Structural Engineer will visit the site during currency of repair work and after the repair work. He will also give the stability certificate of the structure. Note :- The cost of labour, transportation of T&P, scaffolding and making good the disturbed surfaces of structure and all equipment required for testing from point to point are deemed to be included in quoted rate.
Structural auditing of building Nos P-63(G+3) in TRV Area at ICGAS Daman by visual inspection with photography and conducting adequate/required number of ND Tests and preparation and submission of ND test reports comprising the followings:- (a) Site visit, preparation and submission of detailed visual inspection and photography of buildings complete all specified and directed by Engineer-in-Charge. (b) Conducting adequate/required number ND Tests to be conducted by NABL accredited lab including rebound hammer test, Ultra sonic pulse Velocity Test (UPV test), Half-cell protentiometer test (HCP) and Carbonation test, Ultra thickness test, Core test and Compression test, Cover meter test, Chloride Profile test, for steel truss member and magnetic particle inspection for welds to defect surface and sub-surface discontinuity in welds and all other tests which is required for ascertaing the stability of structure, etc. (c) Providing of detailed report and recommendation including remedles for structural improvement/recommendation for further use of buildings or repair works to be carried out duly vetted by IIT/Govt Engineering college. (d) Submission Estimate, suggested repair/remedial measure and product specification of any other special items of material (alongwith manufacturer literature of special item of materials) to be incorporated for repairs. (e) Submission of details repairs for preparation of BOQ alongwith 06 sets of drawings(Hard and soft copy) indicating proposed addition/alteration/repairs. (f) Submission of any other details/documents, as required at the opinion of consultant. (g) Structural Engineer will visit the site during currency of repair work and after the repair work. He will also give the stability certificate of the structure. Note :- The cost of labour, transportation of T&P, scaffolding and making good the disturbed surfaces of structure and all equipment required for testing from point to point are deemed to be included in quoted rate.
Structural auditing of building Nos P-64(G+3) in TRV Area at ICGAS Daman by visual inspection with photography and conducting adequate/required number of ND Tests and preparation and submission of ND test reports comprising the followings:- (a) Site visit, preparation and submission of detailed visual inspection and photography of buildings complete all specified and directed by Engineer-in-Charge. (b) Conducting adequate/required number ND Tests to be conducted by NABL accredited lab including rebound hammer test, Ultra sonic pulse Velocity Test (UPV test), Half-cell protentiometer test (HCP) and Carbonation test, Ultra thickness test, Core test and Compression test, Cover meter test, Chloride Profile test, for steel truss member and magnetic particle inspection for welds to defect surface and sub-surface discontinuity in welds and all other tests which is required for ascertaing the stability of structure, etc. (c) Providing of detailed report and recommendation including remedles for structural improvement/recommendation for further use of buildings or repair works to be carried out duly vetted by IIT/Govt Engineering college. (d) Submission Estimate, suggested repair/remedial measure and product specification of any other special items of material (alongwith manufacturer literature of special item of materials) to be incorporated for repairs. (e) Submission of details repairs for preparation of BOQ alongwith 06 sets of drawings(Hard and soft copy) indicating proposed addition/alteration/repairs. (f) Submission of any other details/documents, as required at the opinion of consultant. (g) Structural Engineer will visit the site during currency of repair work and after the repair work. He will also give the stability certificate of the structure. Note :- The cost of labour, transportation of T&P, scaffolding and making good the disturbed surfaces of structure and all equipment required for testing from point to point are deemed to be included in quoted rate.
Structural auditing of building Nos P-65(G+3)in TRV Area at ICGAS Daman by visual inspection with photography and conducting adequate/required number of ND Tests and preparation and submission of ND test reports comprising the followings:- (a) Site visit, preparation and submission of detailed visual inspection and photography of buildings complete all specified and directed by Engineer-in-Charge. (b) Conducting adequate/required number ND Tests to be conducted by NABL accredited lab including rebound hammer test, Ultra sonic pulse Velocity Test (UPV test), Half-cell protentiometer test (HCP) and Carbonation test, Ultra thickness test, Core test and Compression test, Cover meter test, Chloride Profile test, for steel truss member and magnetic particle inspection for welds to defect surface and sub-surface discontinuity in welds and all other tests which is required for ascertaing the stability of structure, etc. (c) Providing of detailed report and recommendation including remedles for structural improvement/recommendation for further use of buildings or repair works to be carried out duly vetted by IIT/Govt Engineering college. (d) Submission Estimate, suggested repair/remedial measure and product specification of any other special items of material (alongwith manufacturer literature of special item of materials) to be incorporated for repairs. (e) Submission of details repairs for preparation of BOQ alongwith 06 sets of drawings(Hard and soft copy) indicating proposed addition/alteration/repairs. (f) Submission of any other details/documents, as required at the opinion of consultant. (g) Structural Engineer will visit the site during currency of repair work and after the repair work. He will also give the stability certificate of the structure. Note :- The cost of labour, transportation of T&P, scaffolding and making good the disturbed surfaces of structure and all equipment required for testing from point to point are deemed to be included in quoted rate.
Structural auditing of building Nos P-66(G+3) in TRV Area at ICGAS Daman by visual inspection with photography and conducting adequate/required number of ND Tests and preparation and submission of ND test reports comprising the followings:- (a) Site visit, preparation and submission of detailed visual inspection and photography of buildings complete all specified and directed by Engineer-in-Charge. (b) Conducting adequate/required number ND Tests to be conducted by NABL accredited lab including rebound hammer test, Ultra sonic pulse Velocity Test (UPV test), Half-cell protentiometer test (HCP) and Carbonation test, Ultra thickness test, Core test and Compression test, Cover meter test, Chloride Profile test, for steel truss member and magnetic particle inspection for welds to defect surface and sub-surface discontinuity in welds and all other tests which is required for ascertaing the stability of structure, etc. (c) Providing of detailed report and recommendation including remedles for structural improvement/recommendation for further use of buildings or repair works to be carried out duly vetted by IIT/Govt Engineering college. (d) Submission Estimate, suggested repair/remedial measure and product specification of any other special items of material (alongwith manufacturer literature of special item of materials) to be incorporated for repairs. (e) Submission of details repairs for preparation of BOQ alongwith 06 sets of drawings(Hard and soft copy) indicating proposed addition/alteration/repairs. (f) Submission of any other details/documents, as required at the opinion of consultant. (g) Structural Engineer will visit the site during currency of repair work and after the repair work. He will also give the stability certificate of the structure. Note :- The cost of labour, transportation of T&P, scaffolding and making good the disturbed surfaces of structure and all equipment required for testing from point to point are deemed to be included in quoted rate.
M/S. BECQUEREL INDUSTRIES PVT. LTD.
B J MEHTA ARCHITECTURAL AND STRUCTURAL CONSULTANTS PVT.LTD.
GEO DESIGNS AND RESEARCH PVT LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .