Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 LAccepted-Finance 2 2 THACKERAY ROAD KOLKATA 700027 | KOLKATA | KOLKATA | WEST BENGAL | 700027 | ₹4.8 L | L1 | Accepted-Finance ACCEPTED |
| 2 | L2₹4.9 LRejected-Finance | ₹4.9 L | L2 | Rejected-Finance REJECTED |
| 3 | L2₹4.9 LRejected-Finance | ₹4.9 L | L2 | Rejected-Finance REJECTED |
| 4 | L2₹4.9 LRejected-Finance | ₹4.9 L | L2 | Rejected-Finance REJECTED |
| 5 | L2₹4.9 LRejected-Finance | ₹4.9 L | L2 | Rejected-Finance REJECTED |
Tender Value
₹4.9 L
EMD Value
₹9,706
Closing Date
16 Feb 2026, 3:00 pmClosed
Assistant Engineer Alipore Sub Division III PWD
Assistant Engineer Alipore Sub Division III PWD_Old Building 1st Floor_32 Belvedere Road Alipore Kolkata_700027
Repair and Maintenance of underground drain and plinth at block O and P at 7 Diamond Harbour Road Body Guard Line Kolkata for the financial year 25 26
2026_WBPWD_991858_4
WBPWD/AEASDIII/NIET06/2025-26
Open Tender
CIVIL WORKS
21 days
ALIPORE
Please refer Tender documents.
4 documents required · 4 mandatory
₹9,706
Yes
13 Mar 2026
21 Jan 2026
18 Feb 2026
24 Jan 2026
16 Feb 2026
24 Jan 2026
125 mm. thick brick work with 1st class bricks in cement mortar (1:3). In Ground Floor
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity).
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. Pakur Variety
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary. [Excluding cost of chipping over concrete surface] With 1:4 cement mortar 15 mm thick plaster In Ground Floor.
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per 100 sq.m.
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) (i) Single Socketed 3 Meter Length (b) 110 mm
(B) (iii) 110 mm dia Door Tee
(B) (x) 110 mm dia Bend 87.5º
(B) (xi) 110 mm dia Door Bend (T.S.)
Labour for fitting and fixing U.P.V.C.pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineerin- charge. (Payment will be made on centre line measurement of the total pipeline including specials. (A) (ii) 110 mm dia. Above ground
Supplying & laying Double Wall Corrugated (with external annular corrugation and smooth internal walls) High Density Polyethelene Pipes conforming to IS 16098 (Part-II):2013 having Stiffness Class of SN 8 with Ring Stiffness not less than 8.00 KN/Sqm. and Impact Resistance TIR value not more than 10% including necessary jointing materials for nonpressure underground Drainage, Sewerage & Cross drainage application. 200 mm internal dia.
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and excluding one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. i) With Pakur variety. (SAIL/TATA/RINL)
Supplying, fitting and fixing in position reinforced cement polymer concrete manhole /gully pit cover with matching frame.As per I.S-12592(M.D) 5 MT load bearing capacity gully pit cover with frame and hinge arrangement for opening of size Cover: 470 mm X 420 mm X 80 mm Frame: 590 mm X 550 mm X 170 mm opening: 380mm x 305mm Weight: 100 kg (approx)
Supplying, fitting and fixing in position R.C.C. Manhole/ pit cover of approved make with rim of approved make (Heavy type) 560 mm dia.
stage.html
html • 0.17 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.29 MB
Tendernotice_2.pdf
PDF • 0.30 MB
BOQ_2425244.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid