Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹29.0 LAccepted-AOC 179 143 1 INDA NEAR SHAKTI BHAVAN KHARAGPUR 721305 | MEDINIPUR WEST | WEST BENGAL | 721305 | L-1 | Accepted-AOC FOUND LOWEST AND REASONABLE | |
| 2 | L-2₹30.8 L+₹1.0 L (3.45%)Rejected-Finance 38 49 D OLD IDGAH COLONY AGRA U P 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L-2 | Rejected-Finance Being other than lowest | |
| 3 | L-3₹33.8 L+₹4.1 L (13.6%)Rejected-Finance | L-3 | Rejected-Finance Being other than lowest | |
| 4 | L-4₹38.8 L+₹9.1 L (30.5%)Rejected-Finance D 55 HAKIKAT RAI RD ADARSH NAGAR DELHI 33 | L-4 | Rejected-Finance Being other than lowest | |
| 5 | L-5₹39.3 L+₹9.5 L (32.0%)Rejected-Finance | L-5 | Rejected-Finance Being other than lowest |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
27 Feb 2021, 6:00 pmClosed
GE (AF) TECH AREA AGRA
GE (AF) TECH AREA AGRA
REPAIR / MAINT OF FLAME PROOF LIGHTING, SIGN BOARD, FLAME PROOF EXHAUST FAN AND OTHER FLAME PROOF ACCESSORIES UNDER GE (AF) TECH AREA, AGRA.
2021_MES_419835_1
8200-1298/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) TECH AREA AGRA
As per tender documents
8 documents required · 8 mandatory
₹500
GE (AF) TECH AREA AGRA
₹96,000
Yes
28 Apr 2021
6 Feb 2021
1 Mar 2021
6 Feb 2021
27 Feb 2021
15 Feb 2021
6 Feb 2021 - 10 Feb 2021
Amount
Taking down carefully aluminium/copper point wiring (light/fan/socket or power) complete including fitting fixtures such as switches, socket, ceiling rose, brackets, holders, bulk head/tube light fitting etc. and removing materials from site and making good disturbed surface of walls/ floors etc. complete all as specified and directed
Taking down main switch/ MCB DB/bus bar of any type/capacity by disconnecting the electric supply complete all as specified and directed
M&L Point wiring using approved colour coding as per IS, with Zero Halogen Flame retardant (HFFR), smoke free, non toxic, non corrosive installation cable with UNILAY construction copper conductor 1.5 Sq. mm (nominal area), single core, insulated and unsheathed stranded cable 1100 Volts grade ISI-694 marked TEC and FIA approved in & including heavy duty, electric resistance welded (ERW) stove enameled surface Steel mounted conduit, heavy duty ISI marked as per IS:9557 (Part I) 1980 for four light points controlled by one Switch , including HFFR insulated unsheathed unitary construction copper conductor 1.5 Sq. mm nominal cross sectional area wire as earth continuity conductor up to common earth and connecting to earth dolly. All conduit accessories such as bends elbows Tee etc shall be Flame proof certified by CMRS Dhanbad for the follings :-
(a) One light/fan point controlled by one switch
M&L Point wiring for socket point using approved colour coding as per IS, with Zero Halogen Flame retardant (HFFR), smoke free, non toxic, non corrosive installation cable with UNILAY construction copper conductor 2.5 Sq. mm (nominal area), single core, insulated and unsheathed stranded cable 1100 Volts grade ISI-694 marked TEC and FIA approved in & including heavy duty, electric resistance welded (ERW) stove enameled surface Steel mounted conduit, heavy duty ISI marked as per IS:9557 (Part I) 1980 for four light points controlled by one Switch , including HFFR insulated unsheathed unitary construction copper conductor 2.5 Sq. mm nominal cross sectional area wire as earth continuity conductor up to common earth and connecting to earth dolly. All conduit accessories such as bends elbows Tee etc shall be Flame proof certified by CMRS Dhanbad .
M&L One flame proof socket outlet point controlled by single pole one way 16 Amp ON-OFF rotary switch. Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth complete all as specified and directed.
S&F in repair surface and wall mounted Stout Plus LED light fitting of spaces 1205x66x76 ( 20W) with polycarbonate, with one no. 20Watt LED luminaires complete and fixed to wall/ ceiling with fixing accessories and connecting up with & including twin core twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed.
S&F in repair ceiling rose, surface bakelite, 32.5x2.5mm surface type, two to three terminals, AC 240 volts complete all as specified & directed.
S&F in repair flame proof weather rotary switch with cable terminal box in cat aluminum alloy ( LM-6) construction, epoxy powder coated, single pole 16 Amp ON/OFF type, 230 V AC, certified by CMRS for Group IIA & IIB complete including compression glands all as specified and directed.
S&F in repair fluorescent tube light fitting. flame proof type FLP-WP of T5, 1x28W LED including integral reflector made of alluminium alloy LM6 , with electronic ballast, bipin holders, connector block, etc., and all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor with suitable size complete all as specified and directed.
S&F in repair fluorescent tube light fitting CIMFR certified LED flameproof batten suitable for single and twin T8 tube of 16W/20W. Recommended for Gas/Vapour group of IIA & llB and Zone 1 & 2 .IP65 Protected LED flameproof made of aluminium alloy LM6 etc. complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Make- Sudhir/Baliga/Crompton
S&F in repair fluorescent tube light fitting1x36 W flameproof type FLP-WP made of aluminium alloy LM6,with electronic ballast,bipin holders, connector block, etc. complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed .
S&F in repair concealed or fix on wall sheet metal enclosure, single pole and neutral, AC, 240 volts, 8 way, with 200 Amps rated copper bus bar with metal double door and flush to wall including all cutting etc on wall and making good including two coats of white / colour washing / distempering etc to match the existing disturbed surfaces complete all as specified and directed .
S&F in repair MCB, SP, AC, 240 volts of 06 to 32 Amps capacity "C" series and making connections complete all as specified and directed.
S&F in repair MCB, SP, AC, 240 volts of 32 to 63 Amps capacity "C" series and making connections complete all as specified and directed.
S&F in repair isolator, SPN, AC, 240 volts of 6-40 Amps for inductive load connected through cable lugs of suitable size, complete all as specified and directed.
S&F in repair isolator, SPN, AC, 240 volts of 32-63 Amps for inductive load connected through cable lugs of suitable size, complete all as specified and directed.
M&L for FLP-WP threaded type junction box JB/153 Upto 1" ET / M25 4 Way suitable for Flame Proof Exaust Fan of size 380mm (15") complete all as specified and directed
S&F in repair louvers , suitable for flame proof exhaust fan of size 457 mm (18") complete all as specified and directed
S&F in repair blade , suitable for flame proof exhaust fan of size 457 mm (18") , complete all as specified and directed
S&F in repair bird catcher suitable for flameproof exhaust fan of size 457 mm (18") complete all as specified and directed
S&F in repair aluminium blad for flame proof padstal fan of size 457mm (18") complete all as specified and directed
S&F in repair Wire guard for padstal fan of size 457mm (18") complete all as specified and directed
M&L for factory made sheet metal enclosure 240 volts, 4 ways with 200A rated bus bar, SPN, double door type, IP 43- IK 09 with metal door suitable for housing MCBs / isolators and fixed the same on & including mild steel hold fasts of suitable size & shape after grouting the hold fasts, concealed in the wall with and including PCC (1:2:4) type B1 using 20mm graded stone aggregate complete all as specified and directed.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and green for single phase circuits) with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable (Red&Black colour) of size 6.0 sqmm drawn in and including steel rigid conduit not less than 32mm dia with its accessories, surface type, including one run of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable (Green colour) of size 6.0 sqmm as earth continuity and connected of common earth dolly complete all as specified & directed. Note:- Two runs of 6.0 sqmm cable & one run of 6.0 sqmm cable alongwith steel conduit including its accessories shall be measured and paid one unit length.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and green for single phase circuits) with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable (Red&Black colour) of size 4.0 sqmm drawn in and including steel rigid conduit not less than 32mm dia with its accessories, surface type, including one run of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable (Green colour) of size 4.0 sqmm as earth continuity and connected of common earth dolly complete all as specified & directed. Note:- Two runs of 4.0 sqmm cable & one run of 4.0 sqmm cable alongwith steel conduit including its accessories shall be measured and paid one unit length.
S&F in repair 18W 865 419 mm Photon Ultra bright LED PL-L with lamp holders to give glare free light very high efficiency suitable for installation in 4 Pin 36 watt CFL existing fittting complete all as specified and directed.
S&F in repair flame proof FLP - WP rotary switch with cable termination box in LM6 MCB single pole 6 to 16 Amp 10 KA , 220 volt 50 Htz , 16A Single pole ON-OFF as per existing complete all as specified and directed.
S&F in repair flame proof FLP - WP rotary switch with cable termination box in LM6 MCB double pole 25 Amp 10 KA 220 volt 50 Htz , 25A Double pole ON-OFFas per existing complete all as specified and directed.
S&F in repair flame proof flexible mild steel plug of size 300 mm long complete all as specified and directed.
M&L for providing the MCB DB of sheet metal enclosure single pole and neutral 240V, 2 way without bus bar and fixed with mild steel hold fasts grouted in walls with PCC (1:2:4) type B-1 (using 20mm graded stone aggregate),complete all as specified and directed .
Taking down existing old/unserviceable sub main wiring of any type and description, including condute pipe and making good disturbed surfaces of walls, ceilings etc as per existing complete all as specified and directed.
S&F in repair 40 W , LED light fitting energy saving CIMFR certified flame proof wellglass in die cast AI housing with heat resistant toughened glass recommended for Gas/Vapour group of llA & llB and Zone 1&2 .IP65 complete all as specified and directed.
S&F in repair 60 W , LED light fitting energy saving CIMFR certified flame proof wellglass in die cast AI housing with heat resistant toughened glass recommended for Gas/Vapour group of llA & llB and Zone 1&2 .IP65 complete all as specified and directed.
S&F in repair 30 W , LED light fitting street/security light ENDURA CITYLITE PLATINUM PLUS complete with new generation energy saving and environmental friendly long life versatile pressure die-cast aluminium IP66 roadway luminarie with high power LEDs and fixed on walls with the help of GI Pipe brackets made out by 32 mm GI pipe light grade 2.00 mtr long including flate iron clamp made out with 40x6 mm GI strip and necessary nut and bolts all as specified and directed.
Taking down unserviceable Flame proof indoor building light fittings of any type from any height i.e. on building/hanger etc and refixing the same fittings on existing position after replacement of unsereviceable wornout parts/items complet all as specified and directed . Note :- Parts required to be replaced shall be measured and paid saperately under respective item of BOQ as supply only.
Supply only open construction electgromagnetic ballasts suitable for MH fittings of 70 watt complete all as specified and directed.
Supply only open construction electgromagnetic ballasts suitable for MH fittings of 150 watt complete all as specified and directed.
Supply only open construction electgromagnetic ballasts suitable for MH fittings of 250 watt complete all as specified and directed.
Supply only open construction electgromagnetic ballasts suitable for MH fittings of 400 watt complete all as specified and directed.
Supply only 70 Watt metal halide single ended clear tubler lamps(cap base) suitable for MH fittings complete all as specified and directed.
Supply only 150 Watt metal halide single ended clear tubler lamps(cap base) suitable for MH fittings complete all as specified and directed.
Supply only 250 Watt metal halide single ended clear tubler lamps(cap base) suitable for MH fittings complete all as specified and directed.
Supply only 400 Watt metal halide single ended clear tubler lamps(cap base) suitable for MH fittings complete all as specified and directed.
Supply only ignitor suitable for MH Light fitting 70/150/250/400 W complete all as specified and directed.
Supply only of lamp holder porcelain, screw type, of approved make suitable for MH lamp fitting 70W complete all as specified and directed.
Supply only of lamp holder porcelain screw type of approved make suitable for MH lamp fitting 150/250/400 W complete all as specified and directed.
Supply only diamond shape Roto mould diffuser for post top lantern complete all as specified and directed.
Supply only spherical shape Roto mould diffuser for post top lantern complete all as specified and directed.
Disconnection and taking down any type any watt tube light fitting from glow sign board, cleaning repair overhauling including replacement of worn out parts to make it fully functional and re-fixing on existing location complete all as specified and as directed. Note : Parts will be measured and paid separately as supply only under respective items of BOQ .
Supply only fluorscent tube rod with new Ultra bright LED polycarbonate Tubelight with <10% THD with very high efficacy suited for installation in existing old serviceable T8 tube light batten fitting with G13 lamp holders complete all as specified and directed.
Supply only surface and wall mounting batten for G13 T8 type lamps, white powder coated, extruded aluminium housing for efficient heat dissipation for 1200x108x62 (for 20W) box type with polycarbonate diffuser complete all as specified and directed.
S&F in repair, 20 W , Photon ultra plus LED tube light rod with new Ultra bright LED polycarbonate tubelight with <10% THD with very high efficacy suited for installation in existing old serviceable T8 tube light batten fitting with G13 lamp holders and making electric connection complete all as specified and directed.
S&F in repair of surface and wall mounting Universal batten for G13 T8 type lamps, white powder coated, extruded aluminium housing for efficient heat dissipation for 1200x108x62 (for 20W) box type with polycarbonate diffuser and fixed to wall/ ceiling with fixing accessories and connecting up with & including twin twisted copper flexible wire from ceiling complete all as specified and directed.
M&L for fabrication of MS Grill of suitable size for protection of dome light,made out of MS angle iron 25x25x03 mm of required length&Shape of frame (2x2x2 feet) and MS wire of Size SWG-14, fixed to angle iron frame including painting with one coat of red oxide primer and two coats of synthetic enamelled black paint and including the provision of hinges and locking arrangement and including grouting to the pillar of Dome light complete all as specified directed and directed.
S&F in repair 25 W , LED new generation, post top energy saving, environmental friendly, long life esthetically designed with symmetrical light distribution, spun aluminium lnd scape luminaries with high power less as light source with PVC insulated copper conductor of size 1.50 Sqmm, three core of suitable length including connection and testing complete all as specified and directed.
S&F in repair ultra bright LED PL-L light fitting with very high efficiency 18 watt LED suited for installation in existing 2G11 lamp holders. complete all as specified and directed.
S&F in repair 150 watt , LED, JETA PRO PLUS, IP65 flood light fitting complete energy saving,environment friendly , long life ,exclusive innovative die-cast aluminium housing complete all as specified and directed.
S&F in repair 120 watt , LED, JETA PRO PLUS, IP65 flood light fitting complete energy saving,environment friendly , long life ,exclusive innovative die-cast aluminium housing complete all as specified and directed.
S&F in repair 200 watt , LED, JETA PRO PLUS, IP65 flood light fitting complete energy saving,environment friendly , long life ,exclusive innovative die-cast aluminium housing complete all as specified and directed.
S&F in repair LED street/security light fitting of 60 Watt ENDURA PEARL PLUS complete with new generation energy saving and environmental friendly long life versatile pressure die-cast aluminium IP 66 roadway luminarise with high power LEDs, fixed on walls with and including FI clamps , GI Pipe 32 mm dia, 1.5 mtr long in shape complete all as specified and directed.
M&L for rewinding of burnt flame proof Wall mounting fan/ exaust fan/Pedestal fan (after opening and taking out burnt winding) with suitable size of super enameled copper winding wire as per existing/ original specification of exaust fan including proper insulation with varnish etc and testing on full load complete all as specified and directed for the following sizes:-
600 mm sweep, 230 Volt, AC 900 RPM.
300 to 400mm sweep, 230 Volt, AC 900 RPM.
457(18") mm sweep, 230 Volt, AC 1440 RPM.
Taking down of Wall mounted fan/Exhaust fan/Pedestal fan/ Air circulator of any size/ sweep/make from any height of building & dismantling/ opening of blade, stator rotor of ceiling fan for cleaning and servicing/ over hauling by providing oil /grease to the bearings/ bushes and replacement of defective/wornout parts/ spares i.e condenser, bearing, bush, canopy, rubber reel, MS clamp with nut, bolt & washers and locking split pin and reassembling, commissioning testing of ceiling fan including hanging the same on existing location/ place complete all as specified and directed. Note:- Replacement/Renewal of defective/ wornout parts/ spares of fan i.e condenser, bearing, bush, canopy rubber reel, MS clamp and nut, bolt, washers & locking split pin shall be measured and paid separately under respective items of BOQ as supply only.
Supply only of bush suitable for exaust fans, wall mounted and pedestal fans of flame proof any size & type complete all as specified and directed.
Supply only ball bearing suitable for exaust fans, air circulating fan, wall mounted and pedestal fans of Nos. 6201/6202 complete all as specified and directed.
Supply only ball bearing suitable for exaust fans, air circulating fan, wall mounted and pedestal fans of Nos. 6203/6204 complete all as specified and directed.
Supply only of MS nuts & bolts of suitable sizes with split pin complete all as specified and directed.
Supply only of condenser 2.5/ 4.0 mfd suitable for ceiling fans, exaust fans, wall mounted and pedustrial fans of any type & size complete all as specified and directed.
Supply only of aluminium blades suitable size for pedestal/ air circulator fan of 450/ 600mm sweep as per sample complete all as specified and directed.
M&L for repair disconnection and taking down any type of flame proof heating blower for parashuit ,230 V ,250W-500W single phase with heating strip any type , watt, cleaning repair overhauling including replacement of worn out parts to make it fully functional and re-fixing on existing location complete all as specified and as directed. Note : Parts will be measured and paid separately as supply only under respective items of BOQ .
M&L for rewinding of burnt flame proof 1/2HP,1440RPM for Heating blower moter (after opening and taking out burnt winding) with suitable size of super enameled winding wire as per existing/ original specification of heating blower moter including proper insulation & varnishing etc. and testing on full load complete all as specified and directed.
M&L for rewinding of burnt flame proof 1 HP,1440RPM for Heating blower moter (after opening and taking out burnt winding) with suitable size of super enameled winding wire as per existing/ original specification of heating blower moter including proper insulation & varnishing etc. and testing on full load complete all as specified and directed.
Supply only flame proof heating strip 750watt 230v,single phase as per existing size& model suitable for heating blower complete all as specified & directed.
Supply only flame proof heeting strip 1.5kw 230v,single phase as per existing size& model suitable for heating blower complete all as specified & directed.
Supply only of adjustable type thermostat of range 30 degree Celcius to 85 degree Celcius, ISI marked as approved by GE suitable for heating blower complete all as specified & directed.
Supply only contactor (for any type flame proof heating blower for parashuit) 3 phase 20 Amp 415 V, complete all as specified & directed.
GUPTA ENGINEERING WORKS
MISHRA CONSTRUCTION COMPANY
garg construction company
Balaji Associate
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .