| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.6 LAccepted-AOC | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹21.7 L+₹1.1 L (5.36%)Rejected-Finance | L2 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 3 | L3₹23.0 L+₹2.4 L (11.5%)Rejected-Finance 3RD FLOOR BHAKTAMAR RESIDENCY SOMNATHNAGAR ROAD PUNE 411014 | PUNE | PUNE | MAHARASHTRA | 411014 | L3 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 4 | L4₹27.4 L+₹6.8 L (33.0%)Rejected-Finance SADASHIV PHUGE NAGAR OPP SANDVIK FACTORY RADHIKA RESIDENCY F WING FLAT NO 7 PHUGEWADI PUNE 411 012 | PUNE | MAHARASHTRA | 411012 | L4 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 5 | L5₹27.4 L+₹6.8 L (33.2%)Rejected-Finance SHOP NO 10 367 SOMWAR PETH NARPARTGIRI CHOWK PUNE 411011 | PUNE | MAHARASHTRA | 411011 | L5 | Rejected-Finance NOT THE LOWEST TENDERER |
Tender Value
Refer Docs
EMD Value
₹76,000
Closing Date
2 Nov 2024, 6:00 pmClosed
GE MH AND RH KHADKI
Military Engineer Services Garrison Engineer MH and Range Hills Range Hills Road Khadki, Pune 411003
REPAIR REWINDING OF MOTORS SUBMERSIBLE PUMP STARTER ELECTRIC PANEL CABLE MAINTENANCE OF PUMPS AND CERTAIN CONNECTED MISCELLANEOUS ITEMS OF PUMPS MOTORS AT DIFFERENT LOCATION AT AUNDH AND MH KHADKI UNDER GE MH AND RH KHADKI
2024_MES_678235_1
8602/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE MH AND RH KHADKI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MH AND RH KHADKI
₹76,000
21 Dec 2024
5 Oct 2024
4 Nov 2024
5 Oct 2024
2 Nov 2024
19 Oct 2024
5 Oct 2024 - 26 Oct 2024
Amount
M & L for dismantling ,transporting to civil workshop centrifugal pump coupled with electric motor, Split opening of following capacities pumpset including cleaning with kerosene/petrol for removing dirt supply and replacement of small parts like impeller nut ,lock,washer, packing,gasket greasing oiling and reassembling, connecting in position testing, commissioning the pumpset complete all as directed.(Major Part will be Measured and paid in relevant Items of this schedule)
75 HP Motor
60 HP Motor
40 HP Motor
30 HP Motor
25 HP Motor
20 HP Motor
15 HP Motor
7.5 HP Motor
M & L for taking down carefully electric motor 3-phase 415v,50Hz,AC from foundation/ coupling, transporting to civil workshop, opening the motor,Checking the insulation value of the windings, insulating the winding with same class of insulation varnish,Oiling Greassing of bearing and busing , painting with one coat of synthetic enamel paint as per color code and back to site for re-installing the motor and connecting to the pump, testing the motor for satisfactory performance all as directed by Engineer -in-Charge and all as specified for the following capacity. (Major part will be measured and paid in relevant items of this schedule)
75 HP Motor
60 HP Motor
40 HP Motor
30 HP Motor
25 HP Motor
20 HP Motor
15 HP Motor
7.5 HP Motor
Supply and fix in replacement of the following bearings required as directed
75 HP Motor
60 HP Motor
40 HP Motor
30 HP Motor
25 HP Motor
20 HP Motor
15 HP Motor
7.5 HP Motor
Supply and fix in rep terminal block made out from brass complete with backelite plate for the following capacities.
75 HP Motor
60 HP Motor
40 HP Motor
30 HP Motor
25 HP Motor
20 HP Motor
15 HP Motor
7.5 HP Motor
Supply and fix replace bush for pump suitable for the following capacity of pumps
75 HP Motor
60 HP Motor
40 HP Motor
30 HP Motor
25 HP Motor
20 HP Motor
15 HP Motor
7.5 HP Motor
Dismantling and taking out pump motor ,transporting the same work shop opening the motor, removing burnt winding and cleaning winding slots and rewinding of motor using suitable existing gauge/ size with supper enamelled copper wire, replacing insulation paper of class F and fire proof sleeves, varnishing, baking complete, oiling, greasing, replacing old rear/ front bearings with new and reassembling complete motor including testing at site all as directed by Engr- in -charge
75 HP Motor
60 HP Motor
40 HP Motor
30 HP Motor
25 HP Motor
20 HP Motor
15 HP Motor
7.5 HP Motor
Disconnecting electrictrical and mechanicaly and taking out submersible motor pump set of following capacity complete from installed position/ sump , disconnecting of motor, transporting the motor to local workshop ,Split opening of the motor, removing burnt winding and cleaning the slots and rewinding of motor using new super enameled copper winding wire of suitable gauge / size, replacing paper insulation of suitable exisiting class and fire proof sleeves, varnishing etc. complete with oiling, greasing, replacing unsv thrust bearing and bushes after repairing , reassembling complete pump and motor after repairing lowering in existing position and testing all as specified and directed .
25 HP Motor
10 HP Motor
5 HP Motor
3 HP Motor
Taking down old existing unserviceable cast iron / ductile iron pipe M & L DI pipes with socket end or both ends flanged centrifugally cast, class -'B', conforming to IS 8329/ 2000, in any length suitable for flange joint complete all as specified & directed of following sizes:-
DI pipe 300 mm dia
DI pipe 200 mm dia
DI pipe 150 mm dia
DI pipe 100 mm dia
DI pipe 80 mm dia
Taking down old existing unserviceable cast iron / ductile iron pipe M & L CI pipes with both ends flanged centrifugally cast, class -'B', conforming to IS 8329/ 2000, in any length suitable for flange joint complete all as specified & directed of following sizes:-
CI pipe 300 mm dia
CI pipe 200 mm dia
CI pipe 150 mm dia
CI pipe 100 mm dia
CI pipe 80 mm dia
Taking down old existing unserviceable ERW pipe M& L ERW pipes with both ends flanged centrifugally cast, class -'C', in any length suitable for flange joint complete all as specified & directed of following sizes:- ( Note- i) Turning bening, welding, westages are included in quotated rate. ii) Working permission subject to no hamper of daily water supply to the user unit )
ERW pipe 300 mm dia
ERW pipe 200 mm dia
ERW pipe 150 mm dia
ERW pipe 100 mm dia
Taking down fiber board gasket joint M&L for joint with rubber or fibre board gasket complete with suitable size nuts, bolts and washers etc as directed for flanged pipes & fittings for followings sizes:-
300 mm dia
200 mm dia
150 mm dia
100 mm dia
80 mm dia
Taking down unserviceable CI/DI/ fitting of any type, M&L cast iron fitting (any type radius and angle) taper any type (Straight) bend increasing decreasing or double socket etc Tee pieces, single branch ‘Y’ junction double branch, coller, capacity and plugs for up to 80 mm bore to 400 mm CI pipe conforming to IS-1538- 1976 complete all as specified and directed.
Taking down unserviceable foot valve and supply and fixing CI foot valve of following sizes including jointing materials all as specified and directed
150 MM Dia
100 MM Dia
80 MM Dia
Taking down unserviciable and S & F in repair tyre coupling of following sizes with existing alignement all as specifiedand directed
A 18 Size
A 42 Size
A 60 Size
Servicing of Starter Panel of any capacity and any type by using anti rust spray to removal of carbaon from moving contact carbon upto the entire statisfaction of Engr-in-Charge
Taking down unserviciable and Supply and fix in repair 3 pole power contactor of following sizes suitable for existing contactor complete all as specified and directed :-
Taking down unserviciable andSupply and fix in repair SD timer 100 range 3-30 Sec coil voltage 240/360/415 Volt AC. (Make - L&T CAT part No. ST803280000 or equivalent rating on other make )
Taking down unserviciable andSupply and fix in repair thermal overhead relay with start and off/reset of Amps of following ranges suitable for existing all as specified and directed
Relay Range 66-110 Amps
Relay Range 30-50 Amps
Relay Range 24-40 Amps
Relay Range 20-33Amps
Relay Range 14-23 Amps
Relay Range 9-15 Amps
Taking down unserviciable andSupply and Fixing in replacement Water pressure gauge of capacity 5 Kg/mm2 gauge 8 " or 6" (size of dial) all as directed (Make- ISI Make)
Taking down unserviciable and Suupply and fix in repair NRV of size of following size, Class PN 1.6, hydrodynamically guided, closing non return valve with gray Cast iron body, synthetic rubber coated reinforced ball, flanged type including 6mm thick rubber gasket, MS nuts, bolts and washers and dismantling the unserviceable NRV all as directed.
300 MM Dia
200 MM Dia
150 MM Dia
80 MM Dia
Design, fabrication, supply and install, testing and commissioning indoor Panel, including necessary excavation/refilling for trace out incoming and out going cable connection, thimbles of size as required, cubical outdoor type, made out of 2.00 mm thick CRCA sheet, size not less than 1350 mm (height) X 1800 mm (length) X 450 mm (Depth), weather and vermin proof with IP-54 protection, both side openable double door front side & having, locking arrangments on both sides, mounted over angle iron frame at the bottom of height not less than 45 cm above ground level and not less than 30 cm in ground/floor mounted duly grouted in PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) facotry made CPRI approved duly powder coated and write name of motor's connected at outgoing
M & L for Digital Backlight glow sign board star flex made out of 0.75x0.75 mm MS frame box type with back side having galvanised tin sheet of thickness not less than 22 gauges and side cover with powder coated tin sheet including 20 Watt : 02 Nos LED Fitting. The frame box to be fitted welded on MS round pipe as required length 3 to 4 meter each of thickness not less than 6 gauge. The size of the Board should be 8 feet x 3 feet Notes: (a) The rate of PCC work for coping and foundation of these board are included in the quoted rate. (b) The MS frame and MS pipe are to be painted black incolour after one coat of red oxide primer. (c) The Quoted rates are inclusive of dismantling the old glow sign board
Supply and fix 15 ft x 3 fl size, 3 MM ACP sheet Recto reflective Sign board of 1.00 size on frame of MS tubing 40mmx40mm, with 4 nos support of 40mm tubing for board including Side pillar of height 8 ft mounted on RCC coloum made out of 40x40 mm Angle of 6mm thick of 4 nos angle on each columb with support at interval of 2 ft all as specified and directed by Engr-in- charge. Nole:- (1) The content on the board will be finalised with concerned JE/Engr-in-charge. (2) The rates are inclusive of dismantling the old glow sign board from any Height.
Supply and fix 6 Ft x 4 Ft sign board made out of 3MM ACP Sheet LG mark vineyal pasting on 0.75 x 0.75 inch MS frame with vertical side pole of ms angle of size 40x40 mm, 6 mm thickness with necessary excation, PCC and copping all included/all as per specified and directed by Engr-in-charge. Note : (i Content of board to be frinalize with concern of JE/ Engr-in-charge: (i) The rates are inclusive of dismantling the old glow sign board from any Height.
Taking down unserviciable and Supply and fix in repair sluice valve cast iron body double flanged type PN1.6, with SS Spindle, ISI Mark of following capacities
400mm dia
300 mm dia
200 mm dia
150 mm dia
100 mm dia
80 mm dia
Taking down unserviciable and Supply and fix in repair air release valve cast iron body flanged type double acting type, ISI Mark of 200 mm Size
Taking down unserviciable and Supply & fix in repair SS wire rope with PVC Coating of size 10mm dia complete all as specified
Taking down unserviciable and Supply and fix in repair rubber gland packing suitable for sluice valve of following sizes
400 mm dia
300 mm dia.
200/150 mm dia.
100/80 mm dia.
Repair of NRV of size 200 mm flanged type by opening and cleaning inner plate spindle replacement of 6 mm thick rubber gasket, MS nuts, bolts and washers after repairing refixing the same in existing position all as specified and as directed.
M&L painting of ,motor complete set including base plate, of capacity up to 40 HP motors with two coat of synthetic enamel paint over a coat of red oxide primer after preparing surfaces including wiring of MES / SM No all as directed by Engineer-in-Charge.
M&L painting of pump,motor complete set including base plate, of capacity 60 HP to 75 HP motor with two coat of synthetic enamel paint after preparing surfaces all as directed by Engineer-in-Charge.
M&L for cleaning with surface dressing or trimming of natural ground bushes/small trees/shurbes including removing and carrying away the rubbish from site to a distance not exceeding 50m away from all as specified and directed by Engineer-in- charge.
Taking down unserviciable and supply and fix in replacement only RYB indicator lamp LED type (Set of three lamp) for incoming and outgoing supply as per existing sizes all as directed by Engr-in-Charge.
Taking down unserviciable and Supply and Fix in replacement of CTs of 200/5 current rating AC, 415 V, three phase including connecting to supply as per existing all as directed by Engr-in-Charge.
Taking down unserviciable and supply and fix in replacement Ammeter three phase digital type 50 HZ, AC as per existing sizes/ range all as directed by Engr-in-Charge.
Taking down unserviciable and supply and fix in replacement voltmeter three phase digital type 0-500 V, 50 HZ, AC as per existing sizes all as directed by Engr-in-Charge.
Taking down unserviciable and S& F single phase preventor relay SPPR type Sz5 (6 wire) 415 V 50 Hz Make Siemens or equivalent approved make
Taking down unserviciable and M& L for fabrication/structural work with mild steel sheet/ angle iron in any shape or size as indicated or directed and including welding/ bracing, painting with one coat of red oxide primer and two coat of black paint (one coat before fixings and one coat of black paint after fixing ) complete all as specified and directed.
M&L for PCC 1:3:6 ,Type C1, using 20mm graded aggragate for foundations, filling and mass concrete
Material and labour in repair of mild steel plates (plain or chequered) of 5mm thick or over in thickness in available sizes Fe-290 (Gde E-165) complete all as specified and directed.
Supply only PPM testing kit for portable/ drinking water measuring range 0.2 PPM to 5 PPM all as specified and directed (Make- Any approved Coy from Govt Lab)
Taking down unserviciable and Supply and laying in replacement PVC insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade complete layin in trenches /wall/ floor / pipe etc of cross-sectional area of following size
185 Sqmm 3.5 Core
95 Sqmm 3.5 Core
50 Sqmm 3.5 Core
35 Sqmm 3.5 Core
10 Sqmm 4 Core
Taking down unserviciable and M&L for replacement of submersible cable round/flat of 3 core 6 Sqmm with multistanded copper counductor all as specified.
Taking down unserviciable and S & F multicore PVC insulated, PVC Unsheathed industrial cable with flexible bright annealed copper conductor for voltage grade up to 1100 volts conformig to IS 694 for following size
10 Sqmm 3 Core
16 Sqmm 3 Core
4 Sqmm 3 Core
Labour for attending the complaints any type of electric motor / pumps including complaints of electric fault of water supply installations in the AOR of GE (MH & RH) Khadki around the clock on call basis when required and directed including attending the pipe line leakge inside the water supply installation, detect the pump motor cable fault testing, commissioning and making working condition of water supply installations complete all as specified and directed by Engr-in-Charge. Note: (i) Major Spares and material measured and paid separately under relavant item (ii) The quotated rate shall be included the special tool charges requried for attending the fault in quotated rate (iii) Minor spare part required for attending the fault such grease, nut bolts, washers, studs are included in quotated rate.
Taking down unserviciable and Taking down of existing unserviceable water meter 300 mm dia by disconnecting of all nuts bolts and repair the same by replacing all unserviceable parts and calibration / testing the same from MIDC water works authority complete all as specified and directed
S & F MCCB TPN of following sizes suitable for fixing on Panel/ Starter of pump and motor with extended terminals complete all as specified. Make : Schindier / Legrand / L&T / ABB
MCCB 400 Amps, 4 pole, 50 KA
MCCB 315 Amps, 4 pole, 50 KA
MCCB 160 Amps, 4 pole, 36KA
MCCB 100 Amps, 3 pole, 36 KA
MCCB 63 Amps, 3 pole, 36 KA
M&L for cement concrete interlocking tiles 60 mm thick in floor/pavement laid over and including 30 mm thick stone dust/sand cushioning laid dry to profile complete all as specified and directed by Engineer-in-Charge
S & F following size star delta starters for following motors complete all as specified and directed by Engineer-in-Charge
AMAN ENGINEERING AND ELECTIRICALS WORKS (BID ID -3149344)
Adinath Technical Services (BID ID -3150470)
M/S kirpan Enterprises (BID ID -3156077)
M/S - ASHOK ELECTRICALS (BID ID -3150787)
ONKAR ELECTRIC AND GENERAL STORE (BID ID -3150876)
K.K.Enterprises (BID ID -3149653)
SKS Electricals (BID ID -3152634)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .