Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.9 LAccepted-AOC ASTBAL MOHALLA BANASAR BAGH ROAD PATIALA GATE SANGRUR 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹7.9 L+₹61,896.10 (8.52%)Rejected-Finance 544 STREET NO 10 GHUMMAN NAGAR PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹8.4 L+₹1.1 L (15.5%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹8.6 L+₹1.3 L (18.4%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹9.0 L+₹1.7 L (23.5%)Rejected-Finance 300 PREM BASTI 10 SANGRUR SANGRUR PUNJAB 148001 | SANGRUR | PUNJAB | 148001 | L5 | Rejected-Finance Being L5 |
Tender Value
Refer Docs
EMD Value
₹17,200
Closing Date
3 Oct 2022, 6:00 pmClosed
Sh Himanshu, IDSE
MILITARY ENGINEER SERVICES GARRISON ENGINEER SOUTH TARAPORE ENCLAVE PATIALA CANTT
As per tender documents
2022_MES_550508_1
GE(S)/PAT/T-40/N/2022-23
Open Tender
Civil Works
Item Rate
180 days
Mil Stn Nabha
Refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (South) Patiala
₹17,200
Yes
2 Nov 2022
7 Sept 2022
5 Oct 2022
7 Sept 2022
3 Oct 2022
20 Sept 2022
7 Sept 2022 - 13 Sept 2022
Amount
Taking down cement or cement lime plaster on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc.complete all as specified and directed.
Demolition of brick work built in cement mortar.
M&L for brick work in cement mortar (1:4) using sub class 'B' bricks staight or curved on plan exc 6.0 m mean raidus
M & L for 15mm thick ( in two layers of 10mm and 5mm thickness) cement pastering in cement mortar 1:4 and mixig the water proofing compound as per manufactures instructions on brick or concrete surface of wall finished complete all as specified and directed Note : Water proofing compound shall be measured and paid saparately under item .
M&L 10mm thick cement plastering in cement mortar CM 1:6 finishing the surface complete all as specified
M&L for applying acrylic thick wall care putty on internal/external surfaces of walls/ceilings/soffits(thickness vary from1.5to2.5mm as required for desired smoothness and levelling of surfaces in two or more layers)by us ingready made wall careputty including sand papering after filling the putty to make surface smooth and ready for receiving painting etc complete all as specified and directed.
Applying 02 coats of interior emulsion paint (white shade) @ 10 sq.m/litre/2 coats to ceiling surfaces over & including a coat of interior wall primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturer of interior emulsion by using following brands of emulsion and primer complete all as specified and directed.
M&L Preparation of new plastered or unplastered surfaces of walls, two coats of cement base paint all as specified.
Supply only integral water proofing compound ISI marked.
Taking down chowkhats or frames (without taking off shutters from the frame) exc 1.5 Sqm and n. exc 4.00 Sqm incl cutting holes and making good reqd shape for hold fast block for new frame complete all as specified.
All as per srl item No 10 hereinbefore but n. exc 1.5 sqm each.
S&F Powder coated Pressed steel frames made of MS sheet of 1.25 mm thickness for doors with double rebate including necessary fixing lugs, hinges, lock strike plate, hold fasts ,filling PCC (1:3:6 Co) in chowkhats , PCC 1:2:4 B1 hold fast blocks etc., complete as specified,size 125x 60mm including cutting holes and making good reqd to shape for hold fast blocks for new frame complete all as specified. ( Note :- Disturbed portion of existing floor /wall / tile / plaster etc duing fixing of chowkhats shall be repaired to match with existing finish .Cost of the same will be included in this item )
S&F 35mm thick plain framed (Factory made) Panelled shutters of 2nd class HW with lock rail and panels of 9mm B.W.P commercial ply including beading on the facing side of shutters as per SSR Part I clause No 8.17.5. The size of rail and stiles as per IS 1003 (Part I) kiln seasoned and chemically pressure treated all as specified.
S&F 35mm Glazed and skeleton shutters, 2nd class hard wood open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats
preparing of new surface of wood and wood based material of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamel pain and one coat of pink primer all as specified and directed.
S&F Mild steel barrel tower bolt 200mm long stove enamelled black with bright bolt and fixed
S&F Mild steel sliding door bolt of size 250mm , stove enamelled black with bright bolt not less than 16mm dia, with and including a minimum of 6 bolts and nuts, complete all as specified and directed.
S&F MS pressed handles of size 125mm oval type stove enamelled black.
S&F Mild steel butt hinges of size 100mm medium weight cold rolled.
S&F Mild steel butt hinges of size 50mm medium weight cold rolled.
S&F 300 mm long MS rat tail pattern spring hinge including roller and roller plate, complete all as specified.
Factory made steel windows box type using ERW hollow 'P' section comprising double frame for glaged and gauged skelton shutters jointed interally with flat iron 40x4mm complete including grill of 8mm square bar, fixed horrizontally @ 10cm centre to centre, hinges,handle tower bolts,lugs etc all as shown on drawing noTD-219(c) sheet 1/3 to 3/3 and TD-220 (c) sheet 1/3 to 3/3 as applicable complete Note;- (i)for the purpose of measurement& payment double shuttre with frame shall be considered as one unit. (ii) Glaging ,, wire mesh and glass, measured and paid for separately
Sheet glass ordinary quality 4 mm thick and glazing with oil puttly or wooden beads in square not exceeding 0.5 sqm in each pane complete all as specified and directed.
S & F Wire netting of galvanised steel wire 1.40mm dia and size of mesh 25mm fixed with wooden beds tinned tacks of wire staples
M&L for preparing surfaces of any description over 10 cm girth or width, not otherwise described and applying two coats of synthetic enamel paint over a coat of Red oxide on new surfaces of steel or iron, complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings n exc 15cm thickness (below or above ground level), complete all as specified and directed.
M & L Ceramic tiles 8-10mm thick light colour (Square/ rectangular) polished, area of each tile 600 x 600 mm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over 20mm thick screed/ bedding layer in CM 1:4,all as specified and as directed.
M&L fo 25mm thick PCC (1:2:4) type B-0 using 12.50 mm graded crushed stone aggregates in complete all as specified and directed.as in floor base complete all as specified and as directed.
Coloured glazed ceramic tiles (300 x 600 mm) x 7mm or (300 x400 mm)X7mm thick as in vertical surfaces such as skirtings, dados etc jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 10mm thick back coat in CM (1:6), in complete all as specified and directed.
Dismantling of asbestos cement sheets [corrugated, semi-corrugated, etc] in roof coverings complete all as specified
S & F for pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/clading to wall, fixed to self tapping screws as specified
S&F pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in ridges, roof covering/clading to wall, fixed with self tapping screws as specified.
S&F MS hollow rectangular/square/circular tubes/pipes of Fe410-W(Gde-E-250) Grade as in frame work for roof/rafter/purline/chajja/trusses/columns/struts etc and like similar items etc. complete all as specified.
S&F for plates /cleats/connplates of Fe410-W(Gde-E-250)quality A etc for frame work all as specified.
Dismantling of wrought timber truss scantling 40Sq.cm and over in section framed work, provided for complete as directed .
Dismantling of wrought timber scantling as in fillets, post rafter , purlins etc under 40Sq.cm in section framed work, provided for complete as directed .
Hard core of broken stone boulders of gauge 40 mm spread and levelled in layers n exc.15cm thick, watered and rammed to a true surface all as directed and specified
PCC (1:3:6), 50mm thick as in PCC path/ plinth protection.finished the surfaces even and smooth with out using extra cement
Machine pressed precast concrete inter locking paver block any shape and size made of M-35 grade concrete (with grey cement and no pigment) of 60mm thickness with 6mm top layer of anti abrasive material laid over 25mm thick (compacted) fine sieved sand complete all as specified and directed.
M&L for 75mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub base of flooring.
S&F Curtain rod Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness, including cover fillets
M&L anodised aluminium snap grid false ceiling of grid size 605x605mm consisting of aluminium main and "T' sections of size 25x35x1.5mm thick and wall angles of size 25x 25x 1.5 mm thick suspended with GI wire suspenders of 6mm dia of suitable length and 8-10 mm thick gypsum board, 60x60 cm size fixed with staples on snap grid complete all as specified and directed.
S&F PVC wall panelling of hollow section size 150x10mm (colour/pattern as approved by AO)complete fixed in position in all respect including supply and fixing of all accessories like fasteners/ screws/ solvent etc all as recommended by manufacturer all as specified.
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete with fittings and fixtures such as switches, ceiling roses, pendants, regulators, socket, lamp, holders brackets, bulk head, mirror light fittings etc removing material for taking credit ( credit shall be recovered as per credit Sch attached) and also making good disturbed surfaces of wall, floors etc all as specified and as directed by the Engineer-in-Charge.
M&L for point wiring with 1.50 sqmm in copper conductor cable ( multistrand) FRLS single core PVC insulated cable in and including PVC concealed conduit ( ISI Marked) of heavy duly with all accessories ie PVC gutties etc terminated in sunken/pressed metal flush box and white modular cover plate with frame for mounting of switches /sockets/ fan regulators etc and continuous earth wire 1.5 Sqmm copper cable PVC insulated FRLS controlled by one switch for one light/fan/sockets point/ all as specified and directed by Engr-in-Charge in ceiling Portion surface conduit wiring to be done. Note : i) Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost ii) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth. (iii) Necessity cutting chasing where ever required shall be part of job & making good the disturbed surfaces shall be part of job.
All as per item No 46 above, but for one 3/5 pin socket outlet 5 Amp on the same board with other switches complete all as specified and as directed by the Engineer-in-Charge.
All as per item No 46 above, but for one 3/5 pin socket outlet 5 Amp on independent board complete all as specified and as directed by the Engineer-in-Charge.
All as per serial item No 46 here-in-before , but for one socket outlet 15 Amps on independent board with 2.5 Sqmm copper conductor ( Multi-stranded) PVC insulated and unsheating electric cable 1100 volts (ISI Marked) including PVC insulated and unsheathed electric cable 1100 volts 2.5 Sqmm copper stranded conductor as continuous earth wire connected to common earth dolly complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix in replacement of modular switch 1 way, 6 Amps, 1 module completeall as specified.
Supply & Fix of modular type, switch 1 way, 16 Amps, 1 module complete all as specified. Make : Legrand/ Roma/ORIS L&T/Siemens/Wood
Supply & Fix modular type, socket 5 pin 6 Amps, 2 module complete all as specified. Make : Legrand/ Roma/ORIS L&T/Siemens
Supply & Fix modular socket 5 pin 6/16 Amps, combination type 2 module complete all as specified. Make : Legrand/ Roma/ORIS L&T/Siemens/Wood
Supply & Fix modular Fan regulator step type, 120 watts, 1 module complete all as specified. Make : Legrand/ Roma/ORIS L&T/Siemens/Wood
Material and labour for ceiling rose surface type, 65 mm x 50 mm two to three terminals / PVC / polycarbonate, isolated body fixed on PVC block complete all specified and as directed by the Engineer-in-Charge.
Supply and fixing for sub main wiring two single core PVC insulated and unsheathed cable with 6 Sqmm multi -strand copper conductor drawing in PVC casing caping/ Conduit with 6 Sqmm PVC copper conductor cable as in earth wire system ,including taking out old wiring complete all as directed. Note: (i) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth . (ii) Connections of cables with MCBs or bus bars shall be done through brass/copper thimbles of appropriate size . (iii) If Necessary cutting chasing shall be included in this item.
Supply & fix in replacement of existing unserviceable Sheet metal enclosure with new DB’s suitable for MCBs of single pole and neutral 12 way double door type with 200 amp rated bus bar. Note: i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble. ii) The disturbed surface shall be match with existing shall be part of job.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 Amp, in the MCB DB Complete with connection testing and commissioning complete all as specifed and directed
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) SPN current carrying capacity 6 to 32 Amp, in the MCB DB Complete with connection testing and commissioning Complete all as specifed and directed
Supply and fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, one twin core cable flat or circular stranded conductor size of 16 Sqmm, 2 core complete all as specified.
Supply & fix in replacement of FTL with new techonlgy LED having high efficiency of capacity LED 20 Watt, 4 feet long, FIXT ELITE PRIDE PLUS 20 W 6500K, Cool Day Light (CDL) LHEXBLP7PN1W020. Make -Havells. incl necessary electric conection complete all as specified.
Supply & fix in replacement of LED 10 Watt, 2 feet long, Cool day light with NEO Batten10 W 6500K having high efficiency Cat No. LHEXACP7IN1W010. Make -Havells. incl necessary electric conection complete all as specified.
Supply & fix in replacement of lamp holder, PVC/ polycarbonate type with back plate suitable for upto 20 watt bulb for batten fitting, including plastic square board of required size complete all as specified.
Supply & fix in replacement of LED Lamp 12 Watt.
S & F new generation energy saving and environmental friendly long life LED building security light 1x25 watts made up of pressure die cast alluminium housing with high power LED as light source and lense embedded PC cover having TOP OPENING separate driver compartment with IP65 protection and impact resistance of IK07, with all accessories including suitable bracket with suitable dia light grade GI pipe bend to shape, including MS clamp of size of required size and PVC cable 1.5 Sqmm twincore from ceiling rose to light fittings complete all as specified and directed.
M&L for replacement of existing unserviceable earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth plate not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth wire 4mm dia by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) including iron angle frme 40*40*6mm. and medium grade GI watering pipe 20mm dia with funnel and wire mesh and 15 mm bore GI pipe light grade proection pipe including excavation and charcoal ,common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I
S & F energy saving 3 star rating ceiling fan 1200mm sweep energy efficent as per latest specifications having service value more than 5.5 make: Havells or equivalent in Usha/ Bajaj and suspended from fan hook including electrically connecting with twisted three core PVC insulated unsheathed flexible cord of 0.75 Sqmm copper conductor from ceiling rose to ceiling fan.
FAVOURITE ENGINEERS
m/s panchmukhi builders
Vipin Kumar and Brother
AGGARWAL & CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .