Loading…
Loading…
Tender Value
₹1.2 Cr
EMD Value
₹2.4 L
Closing Date
5 Oct 2026, 11:00 am
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
MALDA DIV
14 conditions · 3 needing a document upload
(1) As per item no 10.0 of GCC 2022 and Advance Correction Slip No.1 to 11 of Indian Railways Standard General Conditions of Contract, April' 2022 (Copy attached in download section) - Supporting Document Mandatory. (2) Submit requisite information as per Annexure-VIB, along with copy of Audited Balance Sheets - duly certified by CA / Certificate from CA duly supported by Audited Balance sheet is mandatorily.
(1) As per item no 10.0 of GCC 2022 available in Document section and Advance Correction Slip No.1 to 11 of Indian Railways Standard General Conditions of Contract, April' 2022 (Copy attached in download section) is applicable. Document mandatory. (2) Annexure-V and V(A) of GCC 2022 is mandatory.
Definition Of Similar Work : - Any Telecom work involving provision of MIS/LAN /WAN / Helpline / UTS/ PRS / FOIS / value added enquiry system / video enquiry system / Data connectivity / Datacom equipment./ video conferencing / wireless communication/secured communication/Wi-Fi /Telecom work involving computer based enquiry system.
54 conditions · 10 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Scanned copy -in PDF format- of the details regarding the Association of Railway Officers with the tenderer -for details please refer ANNEXURE-U-V of Coml Compliance.
Scanned copy -in PDF format- of the details of the works the tenderer presently in hand during the last three years -for details please refer ANNEXURE-IV Coml Compliance.
Scanned copy -in PDF format- of the details of the List of the Arbitration cases of the tenderer during last 5 years -for details please refer ANNEXURE-U-VI of Coml Compliance.
Scanned copy -in PDF format- of the details of the List of the Court cases of the tenderer during last 5 years -for details please refer ANNEXURE-U-VII of Coml Compliance.
Scanned copy of the NEFT in PDF format as per Annexure - U-VIII of of Coml Compliance.
In case (i) the office is closed due to any reason or (ii) any one of opening official is on leave or out from Head Quarter, on the stipulated date & time of opening of the tender, whatsoever the tender will be Opened on the next working day on which both opening officials are present at Head Quarter.
The Railway reserves the right to verify all statements, information and documents submitted by the bidder in his tender offer, and the bidder shall, when so required by the Railway, make available all such information, evidence and documents as may be necessary for such verification. Any such verification or lack of such verification,by the railway shall not relieve the bidder of its obligations or liabilities hereunder nor will it affect any rights of the railway thereunder.
In case of any wrong information submitted by tenderer, the contract shall be terminated, Earnest Money Deposit (EMD), Performance Guarantee (PG) and Security Deposit (SD) of contract forfeited and agency barred for doing business on entire Indian Railways for 5 (five) years.
Each page of the copy of documents/certificates in support of credentials, submitted by the tenderer, shall be self-attested/digitally signed by the tenderer or authorized representative of the tendering firm. Self-attestation shall include signature, stamp and date (on each page).
(A) S&T estimate in connection with Provision of 1st FOB at Rishikund & Sarobag station. (B) S&T estimate in connection with Provisioning of Existing stair case with 2 nos of lift at PF No- 1 and PF No-2 &3 at same FOB at BGP stn (C) Upgradation of TKLE,DWLE,BHLE & BRPS STATION and other Passenger Amenities in BGP-DUMK Section under AEN/BGP, (D) Improvement of PF surface, water booth, station buildings including improvement of water supply and drainage facilities at GZM, JMQ, KTJ CMX, (E) Improvement of PF surface, water booth station, buildings including water supply & drainage facilities at Noapara MPLE, MPLR, PRDG, BHW, TPH, (F) Provision of CCTV Camera for Officers Railway Colony of Malda
MLDT_SNT_26-27_20_OT~ER
MLDT_SNT_26-27_20_OT
Open
Works - General
365 Days
Maldah, West Bengal
₹0
₹2.4 L
11 Sept 2026
11 Sept 2026
21 Sept 2026
172 items across 6 schedules · ₹1,22,15,446.28 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Supply of full size apparatus case (GKP type) (as per Drawing No. SW SK NO. 4/90 & other applicable GKP SW Drawing). This includes supply of a location box (GKP type) with 'E' type lock & key, fitted on the location door on both side, E Type lock (ward No. will be specified by Engineer-in Charge) as per RDSO Drg. No. SA-3376 and Key to Drg. No. SA-3377 as per RDSO Drawing No. S-11500. Inspection: Consignee. | Numbers | 6.00 | 17,543 | 1,05,258 |
| 2 | Casting, concreting and curing of concrete foundation (in ratio 1:3:6), erection and installation of full size apparatus case as per Drg. No. S&T/C-6/98(NKG). This includes the cost of all materials required for fixing holding down bolts, casting, concreting. Note: Bolts, nuts and washers, bitumen compound to be supplied by contractor and bitumen compound to be used in between apparatus case and foundation. This also includes the bottom of apparatus cases filled with sand and the outside covered with masonry work and neat cement plastering. Note: Painting the apparatus case inside and outside with one coat of red oxide, two coats of aluminium paints outside and white paint inside. | Numbers | 6.00 | 13,705 | 82,230 |
| 3 | Supply of 48 fiber armoured Optical fiber cable as per RDSO specification no.- RDSO/ SPN/TC /110/2020 (Rev.0) or latest. Inspn: Consignee | Kilometre | 3.00 | 69,036.55 | 2,07,109.65 |
| 4 | Supply of 40 mm. dia. permanently lubricated HDPE telecom: ducts (with chord) as per RDSO Spec. No. RDSO/SPN/TC/45/2013 Rev.2.0 with latest amendments or Latest in length of 1000 mtrs./roll For each km. of HDPE duct following items are to be supplied (a) end plugs-2 nos. (b) cable sealing plugs - 2 nos. (c) plastic couplers slip fit/push fit type-2 nos. (d) end plugs to be provided along with drum 2 nos. Color to be specified by Railways. Inspection: Consignee. | Kilometre | 3.00 | 79,596 | 2,38,788 |
| 5 | Laying of HDPE pipe duct, 40/33 mm in trenches and protective works including pulling of mono-mode armored OFC cable (24 fibers) through duct in trenches and as advised by site engineer. Note: - (1) the contractor will take over the OFC cable from railway store to site of work duly checked the continuity of each fiber from end to end. (2) before & after laying of optical fiber cable through duct, continuity test from end to end of each fiber to be made by the contractor to ensure availability of all 24 fiber duly certified by the site engineer. | Kilometre | 3.00 | 24,734 | 74,202 |
| 6 | Excavation of OFC pit for cable jointing of size 1.5m x 1.5m x1.2 m for all type of soils. The section. Back filling the pit and ramming after jointing. Provision of brick walling the four walls and bottom of pit with RCC slab, back filling with earth and ramming as per drawing. N.B. all the materials including cement required for the above will be supplied by the tenderer. | Numbers | 6.00 | 6,674 | 40,044 |
| 7 | Jointing, terminating & splicing of 48 fiber optic fiber cable and fixing of termination box/FDF/placing of joint closures in the pit required at various locations including transportation of all the jointing & terminating materials from railway store to the work site and returning leftover materials to the railway store. | Numbers | 6.00 | 21,250 | 1,27,500 |
| 8 | Supply of optic fiber splice closure (24 fiber) as per tec. Specification no. G/OJC-02/01, March'99 with latest amendment or latest including all miscellaneous items and consumables for fiber splicing. Inspection: - by consignee. | Numbers | 4.00 | 3,558 | 14,232 |
| 9 | Supply & Installation of 48F LIU installation with splicing The OFC Termination box to be supplied as per TEC No. G/FTB 01-02 March- 99 or latest, Splice losses in no case should be more than 0.1 dB. Necessary 0 dB connectors should be Provided by contractor in OFC termination box. Inspection: - by consignee. | Numbers | 4.00 | 51,336.32 | 2,05,345.28 |
| 10 | Supply, installation and complete wiring of Optical fiber cable termination box for 48 fibers complete with base housing, base mountings with fixing arrangement etc & splicing of fibers with low loss of pigtail cables as per required. Two pairs of fibers shall be derived from either side of OFC cable at every OFC cable hut provided at wayside stations through pigtails with FC/PC connectors and remaining fibers on either side will be made through by splicing. At OFCterminal stations/MW repeater stations, all fibers shall be derived from either side and to be terminated in OFC termination box through pig tails and FC/PC connector. Inspection: - by consignee. | Numbers | 4.00 | 25,668.35 | 1,02,673.4 |
| 11 | Supply of LC-SC Patch cord ( 3 m length) armoured, , R&M make or superior. Inspection: - by consignee. | Numbers | 30.00 | 1,800 | 54,000 |
| 12 | Supply of LC-LC Patch Cord ( 3 m length) armoured, , R&M make or superior Inspection: - by consignee. | Numbers | 30.00 | 1,800 | 54,000 |
| 13 | Supply of SC-SC Patch cord ( 3 m length) armoured, , R&M make or superior. Inspection: - by consignee. | Numbers | 20.00 | 1,800 | 36,000 |
| 14 | Supply of patch chord cable (10-meter-long) with FC/PC connectors compatible with SDH equipment as per TEC Specn.No.GR/OFJ-02/01 May 2004 with latest Amendment. Inspection: Consignee. | Numbers | 50.00 | 909 | 45,450 |
| 15 | Supply, fixing and wiring of surge protection device in attachment plug module with replaceable surge protection for coaxial signal, interfaces N-connector plug/socket installed as surge protection between antenna and 25 W VHF sets, make- Phoenix Contact model CN-UB-280DC-SB- 2818148 or similar as per specifications. this includes mounting plate and reserve gas filled surge arrestor (one no.) with all required connectors/clamp for commissioning of SPD at site. Inspection: Consignee. | Numbers | 5.00 | 6,985 | 34,925 |
| 16 | Laying of UTP/STP CAT-6 cable/power cable in PVC casing capping of appropriate size. The work also includes supply and fixing of casing and capping, fixing and connection of patch panel, fixing of CAT-6 cable with RJ 45 connectors. Work to be done as per instructions of site in-charge. | Metre | 900.00 | 45 | 40,500 |
| 17 | Laying of Power Cable/STP/UTP CAT-6/LS cable through flexible PVC Conduit Pipe/ GI Pipe/HDPE Pipe (where necessary) as per direction of the Rly. Representative, including any fixing of cables/PVC pipe/PVC Casing on wall/shed with suitable clamps (the clamps and screws should be made of Stainless steel). All the fixing materials including Collar, bend, junction etc. shall be supplied by the contractor. This also includes transportation of materials from store to the site. | Metre | 900.00 | 19 | 17,100 |
| 18 | Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. wide at bottom without brick as per DRG. NO. S&T/C-40(NKG), SK/4/95/NKG, SK/8/95/NKG. or latest alongside the track in all kinds of soil, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc. The work shall be done as per the extant practice on Eastern Railway and instructions of Railway Engineer at site. In case 1.2m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1.2m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1.2m. Note:-(a) for all trenches from distant signal to home signal and to relay room, the minimum headway above the uppermost cable in the trench should be 600mm. If due to a large no. of cables headway is not available, 4" of 1:2:4 concreting should be done, (b)Payment will be made as per actual work done on pro-rata basis, if required depth is not available at site & (c) if the depth of trench is not uniform in a span of 100 mtr. or shorter lengths if site condition demands along the cable run, minimum depth will be taken for that particular stretch for payment. | cum | 2520.00 | 245 | 6,17,400 |
| 19 | Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/Trunking. This also includes laying of cables in track crossings & road crossings. Item includes provision of labels of coloured plastic adhesive tapes or any other identifiable material on eachcable to give the cable number at each Gantry Post/hectometer post.(Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes.(HERE UNIT METRE MEANS RM) | Metre | 8.00 | 5 | 40 |
| 20 | Digging of trench 1.2 Mtrs. deep from rail flange/ road level and 0.3 Mtrs wide and back filling after placing of DWC/ RCC/GI pipe. (Placing of DWC/RCC/GI pipe covered separately).The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. For track crossing, RDSO sketch No. SDO/CABLE LAYING/009 or latest and for Road Crossing, RDSO sketch No. SDO/CABLE LAYING/010 or latest are to be followed. | cum | 100.00 | 278 | 27,800 |
| 21 | Supply, Transportation at site and Installation of RCC cable route marker engraved and painted on both side along the route at every 50 meter and at route diversion. The cable marker is to be fabricated as per RDSO drawing No. RDSO/Cable Laying/020, issued vide RDSO document No. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest. The fixing work is to be done as per extant practice of E. Rly. and as per Railway site supervisor. Inspection: - by consignee. | Numbers | 100.00 | 417 | 41,700 |
| 22 | Supply of Medium class GI pipes 100 mm dia(4.5 mm thickness) as per IS 1239 ( Part 1 ) : 2004 or Latest with socket & coupling on culverts bridges or at any other locations as decided by Site Engineer. It includes supply of all material required for fixing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends. Inspection: - by consignee. | Metre | 100.00 | 762 | 76,200 |
| 23 | Laying & Fixing of Medium class GI pipes 100 mm dia(4.5 mm thickness) as per IS 1239 ( Part 1 ) : 2004 with socket & coupling on culverts bridges or at any other locations as decided by Site Engineer. It includes installation of all material required for fixing arrangement. Contractor will install flexible/corrugated HDPE pipe at the end of GI pipe along with any masonry work(if required) to protect the cables from sharp edges and sudden bends. | Metre | 100.00 | 98 | 9,800 |
| 24 | Jointing of 4/6 quad /Signalling cable with heatshirnkable statight through jointing kits. All the material required for the work are to be arranged by contractor himself at his own cost except Thermoshrink jointing kit/ Rapid jointing kit. after jointing the cable through test such as insulation test continuity cable losses etc to be carried out jointly with rly engineer. If any defect or any damaged is observed during jointing , the contractor has to re do the joint free of cost. | Job | 10.00 | 956 | 9,560 |
| 25 | Supply of Thermoshrink universal jointing kit for quad cable for staight joint as per RDSO Specification IRS/TC/77/2012 Rev3.0 with latest amd. | Numbers | 10.00 | 2,185 | 21,850 |
| 26 | Supply and installation testing commissioning of 24 port Gigabit ethernet PoE Switch with 4 SFP Port along with supply of 4 SFM module, Brand D-Link (DGS-1210-24P) or similar. Acepted make: Cisco/Juniper/D-Link/Avaya/ Aruba/Netgear/HP/TP-Link etc. Inspection: - by consignee. | Numbers | 2.00 | 39,330 | 78,660 |
| 27 | Supply, Fixing & Instsallation of 9U Rack with locking front glass door and fully loaded vented rear steel door compitiable with standard 19 inch accessaries with power strip with all accessories Make HCL/Bestnet/Verpresident. Inspn : Consignee. | Numbers | 2.00 | 7,598 | 15,196 |
| 28 | Supply of frame, surface box and white cover plates for Two modules ( IO BOX ) . This also includes supply of RJ-11 Telephone sockets with level holder Jack type/ RJ-45 LAN sockets Jack Type (Tool less) and blanking plates for one modules as pert requirement. Make: Legrand or superior. Inspection: Consignee. | Numbers | 10.00 | 602.6 | 6,026 |
| 29 | Fixing of frame, surface box and white cover plates for Two modules(IO BOX). This also includes fixing of RJ-11 Telephone sockets with level holder Jack type, RJ-45 LAN sockets Jack Type (Toolless) and blanking plates for one modules. Make: Legrand or superior. Inspection: Consignee. | Numbers | 10.00 | 150.65 | 1,506.5 |
| 30 | Supply of RJ-45 connector (10/100 base T with gold plated pins) (Box of 100Nos. ) Inspection: - by consignee. | Boxes | 2.00 | 612.9 | 1,225.8 |
| 31 | Supply of FR CAT-6 UTP Cable suitable for 10BASE- T/100BASETX/and 1000BASE-T(Gigabit Ethernet). Make: DLINK/AMP/Avaya/Krone/Bestnet/Aambernet. Inspection: Consignee. | Metre | 915.00 | 25 | 22,875 |
| 32 | supply and installation of Ahuja CCS 2300 Counter Communication Systems. Inspection: - by consignee. | Numbers | 4.00 | 12,000 | 48,000 |
| 33 | Supply of Laser Source meter as per Specification No. TEC/GR/TX/OPM-001/04/NOV-13 of model Viavi OLS 35 or similar. Inspection: - by consignee. | Numbers | 1.00 | 87,947 | 87,947 |
| Schedule total | ₹25,45,143.63 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
LetterofcreditAnnexure-B.pdf
ATTACHMENT
AnnexureVIBContractualTurnoverGCC2022.pdf
ATTACHMENT
Tele_Cir_9-20231.pdf
ATTACHMENT
GCCACSNo.5.pdf
ATTACHMENT
GCCACSNo.1.pdf
ATTACHMENT
AnnexureUV_1.pdf
ATTACHMENT
AnnexureU-VII.pdf
ATTACHMENT
AnnexureU-VI.pdf
ATTACHMENT
GCC2022_1.pdf
ATTACHMENT
REVISED_FORMAT_FOR_CERTIFICATE_28042023.pdf
ATTACHMENT
AnnexureIV.pdf
ATTACHMENT
AnnexureU-VIII.pdf
ATTACHMENT
GCCACS.pdf
ATTACHMENT
AnnexureIAnnexureIIandAnnexureIII.pdf
ATTACHMENT
GCCACSNo.2.pdf
ATTACHMENT
GCCACSNo.3.pdf
ATTACHMENT
GCCACSNo.6.pdf
ATTACHMENT
GCCACSNo.4.pdf
ATTACHMENT
GCCACSNo.9.pdf
ATTACHMENT
GCCACSNo.7.pdf
ATTACHMENT
TechnicalcircularNo.123regardingPVCInsulatedRailwaySignallingIndoorSingle_Multicorecable.pdf
ATTACHMENT
GCCACSNo.8.pdf
ATTACHMENT
GCCACSNo.11_compressed.pdf
ATTACHMENT
GCCACSNo.10.pdf
ATTACHMENT
ChangesinBGFormat.pdf
ATTACHMENT
e-BankGuaranteee-BG.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .